• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 227
  • 2
  • Tagged with
  • 230
  • 230
  • 230
  • 160
  • 153
  • 136
  • 113
  • 56
  • 53
  • 40
  • 36
  • 36
  • 28
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da influência do laser de baixa intensidade na movimentação ortodôntica e supressão da dor / Influence of low-level laser irradiation on orthodontic movement and pain level

Juliana Moura Storniolo de Souza 05 December 2014 (has links)
Analisou-se a velocidade de movimentação ortodôntica e sensibilidade dolorosa de caninos superiores e inferiores submetidos à irradiação com o laser de baixa intensidade (LBI) em dose única mensal, comparados aos caninos contralaterais não irradiados (controle). Foram selecionados 11 indivíduos, portadores de má oclusão de Classe I com indicação de extração dos primeiros pré-molares superiores e inferiores. O laser de baixa intensidade foi aplicado após a ativação da retração inicial dos caninos, realizada através de mola Niti com uma força de 150g. A aplicação do laser foi realizada em 10 pontos (5 por vestibular e 5 por lingual) nos caninos superiores e inferiores, utilizando o seguinte protocolo: Canino inferior por vestibular e lingual e canino superior por vestibular: Potência de 40mW; densidade de energia de 10J/cm2; 10 segundos por ponto; energia por ponto de 0,4J, uma energia total de aplicação de 4J para o canino inferior e 2J por vestibular dos caninos superiores e para o canino superior por palatino o protocolo foi: Potência de 70mW; densidade de energia de 35J/cm2; 20 segundos por ponto; 1,4J de energia por ponto, energia total de 7J. A retração durou 3 meses, num total de 3 aplicações de laser. Foi obtido um par de modelo de gesso inicial após as extrações dentárias e mensalmente antes da aplicação do laser que posteriormente foram escaneados com scanner 3Shape Ortho SystemTM \"(3ShapeTM Copenhagen, Dinamarca) e as imagens tridimensionais avaliadas por meio do software OrthoAnalyzer (3Shape) para mensuração da quantidade de movimentação dos caninos retraídos. Os pacientes preencheram uma escala visual após 12, 24, 48 e 72 horas da ativação da retração inicial dos caninos para avaliação da sensibilidade dolorosa. Para comparação da velocidade da movimentação ortodôntica e o nível de dor entre os lados irradiado e não irradiado nos três períodos avaliados, foi utilizado a Análise de Variância a um critério de medidas repetidas. Em todos os testes adotou-se nível de significância de 5%. Os resultados demonstraram diferença estatisticamente significante entre a quantidade de retração dos caninos irradiados comparados aos caninos não irradiados somente para os caninos inferiores no primeiro mês de aplicação do LBI. Em relação à sensibilidade dolorosa o LBI não foi efetivo em nenhum dos tempos avaliados. Concluiu-se assim que o LBI no protocolo utilizado só foi eficiente na aceleração da movimentação dentária dos caninos inferiores no primeiro mês de aplicação, porém não gerou redução da dor experimentada pelos pacientes frente às forças ortodônticas. / It was analyzed the orthodontic tooth movement and painful sensibility of maxilary and mandibular canine teeth submitted to irradiation with low-level laser (LLL) in an only monthly dose, compared to the non-irradiated contralateral canines (control). Eleven individuals with Class I malocclusion with indication of extraction of the first maxillary and mandibular premolars were selected. The low-level laser was applied after the activation of initial retraction of the canine teeth, performed with Niti coil springs with force of 150g. The laser application was performed in 10 points (5 buccal and 5 lingual) in the maxillary and mandibular canines, using the following protocol: Mandibular canine buccal and lingual and maxillary canine buccal: 40mW power; an energy density of 10 J/cm2; 10 seconds per point; energy per point 0,4J, a total energy of 4J applying to the mandibular canine and 2J the buccal of the maxillary canines and maxillary canine palatally: 70mW of power; an energy density of 35J/cm2; 20 seconds per point; 1,4J energy per point, the total energy 7J. The retraction lasted three months, a total of three laser applications. It was obtained a couple of dental casts after dental extractions and monthly model before applying the laser which were subsequently scanned with scanner \"3Shape\'s Ortho SystemTM\" (3ShapeTM - Copenhagen, Denmark) and three-dimensional images evaluated through OrthoAnalyzer software (3Shape) to measure the amount of movement of canines retracted. Patients completed a visual scale after 12, 24, 48 and 72 hours of initial activation of canine retraction for evaluation of pain sensitivity. To compare the speed of orthodontic tooth movement and the level of pain between the irradiated and non-irradiated sides at the three movement stages, repeated measures one-way analysis of variance was used. In all tests we adopted a significance level of 5%. The results showed statistically significant difference between the amount of retraction of the irradiated canines compared to the non-irradiated ones only for the mandibular canines in the first month of application of LLL. Regarding the soreness LLL was not effective in anytime evaluated. It was therefore concluded that LLL in the protocol used was effective only in the acceleration of tooth movement of the mandibular canines in the first month of application, but it did not cause reduction of pain experienced by patients ahead to orthodontic forces.
22

Influência do laser de baixa intensidade na movimentação ortodôntica - avaliação clínica e radiográfica / Influence of low-level laser irradiation on orthodontic movement clinical and radiographic evaluation

Pereira, Suelen Cristina da Costa 12 December 2014 (has links)
Este estudo é um ensaio clínico randomizado duplo-cego que avaliou a influência do laser de baixa intensidade (LBI) na movimentação ortodôntica de caninos superiores e inferiores, comparando-os aos caninos contralaterais não irradiados (controle). Foram selecionados 11 pacientes, portadores de má oclusão de Classe I com indicação de extração dos primeiros pré-molares superiores e inferiores. O laser infravermelho de baixa intensidade foi aplicado após a ativação da retração inicial dos caninos, realizada através de mola NiTi com uma força de 150g. A aplicação do laser foi realizada em 10 pontos (5 por vestibular e 5 por lingual) nos caninos superiores e inferiores, utilizando o seguinte protocolo, em dose única mensal: canino inferior por vestibular e lingual e canino superior por vestibular Comprimento de onda de 780nm; Potência de 40mW; densidade de energia de 10J/cm2; 10 segundos por ponto; energia por ponto de 0,4J, uma energia total de aplicação de 4J para o canino inferior e 2J por vestibular dos caninos superiores e para o canino superior por palatino o protocolo foi - Potência de 70mW; densidade de energia de 35J/cm2; 20 segundos por ponto; 1,4J de energia por ponto, energia total de 7J por palatino e total de 9J para o canino superior. A retração durou 3 meses, num total de 3 aplicações de laser. Para mensuração da quantidade de movimentação dos caninos retraídos, medições clínicas mensais foram realizadas com paquímetro digital, logo após as extrações dentárias e antes de cada aplicação do laser. Para comparação da velocidade da movimentação ortodôntica entre os lados irradiado e não irradiado nos três períodos avaliados, foi empregada a Análise de Variância a um critério de medidas repetidas, seguida do Teste de Tukey. Para verificação da integridade tecidual, foram efetuadas radiografias periapicais iniciais e finais dos caninos retraídos, nas quais foram avaliados uma possível reabsorção na crista alveolar, por meio da distância da crista óssea alveolar até a junção cementoesmalte e os níveis de reabsorção radicular, por meio do índice de Levander e Malmgreen. Para isto, foi empregado o teste não paramétrico de Wilcoxon. Em todos os testes adotou-se nível de significância de 5%. Os resultados demonstraram que não houve diferença estatisticamente significante na velocidade de retração dos caninos irradiados comparados aos não irradiados, em nenhum dos períodos avaliados. Em relação à influência do LBI nos níveis de reabsorções radiculares e ósseas, não foram encontradas diferenças significantes entre os grupos estudados. Concluiu-se assim que o LBI, no protocolo utilizado, não foi eficiente na aceleração da movimentação dentária e não promoveu danos aos tecidos de suporte do dente. / This study is a double-blind randomized clinical trial that evaluated the influence of low-intensity laser on orthodontic movement of upper and lower canine teeth, compared to the non- irradiated contralateral canines (control). Eleven patients with Class I malocclusion with indication of extraction of the first upper and lower premolars were selected. The infrared low-level laser was applied after the activation of initial retraction of the canine teeth, performed with NiTi coil springs with force of 150g. The laser application was performed in 10 points (5 buccal and 5 lingual) in the upper and lower canines, using the following protocol, in an only monthly dose: Lower canine buccal and lingual and upper canine buccal 780 nm wavelength; 40mW power; an energy density of 10 J/cm2; 10 seconds per point; energy per point 0,4J, a total energy of 4J applying to the lower canine and 2J the buccal of the upper canines and upper canine palatally - 70mW of power; an energy density of 35J/cm2; 20 seconds per point; 1,4J energy per point, the total energy 7J and total 9J to the upper canine. The retraction lasted three months, a total of three laser applications. To measure the amount of movement of canines retracted, monthly clinical measurements were made with a digital caliper (Mitutoyo - Japan), after tooth extractions and before each laser application. To compare the speed of orthodontic tooth movement between the irradiated and non- irradiated sides at the three movement stages, repeated measures one-way analysis of variance was used, followed by the Tukey test. For evaluation of tissue integrity, initial and final periapical radiographs of retracted canines were obtained, to evaluate a possible alveolar crest resorption by assessment of the distance from the alveolar bone crest to the cementoenamel junction, as well as the level of root resorption by the Levander and Malmgreen index, which was evaluated only on retracted canines. The nonparametric Wilcoxon test was applied for that purpose. In all tests we adopted a significance level of 5%. The results showed no statistically significant difference between the amount of retraction of the irradiated canines compared to the nonirradiated ones, in all evaluated periods. Regarding the influence of LLL in the levels of root and bone resorption, no significant differences between groups were found. It was therefore concluded that LLL in the protocol used was not effective in the acceleration of tooth movement and did not cause damage to the supporting tissues of the tooth.
23

Avaliação da influência do laser de baixa intensidade na movimentação ortodôntica e supressão da dor / Influence of low-level laser irradiation on orthodontic movement and pain level

Souza, Juliana Moura Storniolo de 05 December 2014 (has links)
Analisou-se a velocidade de movimentação ortodôntica e sensibilidade dolorosa de caninos superiores e inferiores submetidos à irradiação com o laser de baixa intensidade (LBI) em dose única mensal, comparados aos caninos contralaterais não irradiados (controle). Foram selecionados 11 indivíduos, portadores de má oclusão de Classe I com indicação de extração dos primeiros pré-molares superiores e inferiores. O laser de baixa intensidade foi aplicado após a ativação da retração inicial dos caninos, realizada através de mola Niti com uma força de 150g. A aplicação do laser foi realizada em 10 pontos (5 por vestibular e 5 por lingual) nos caninos superiores e inferiores, utilizando o seguinte protocolo: Canino inferior por vestibular e lingual e canino superior por vestibular: Potência de 40mW; densidade de energia de 10J/cm2; 10 segundos por ponto; energia por ponto de 0,4J, uma energia total de aplicação de 4J para o canino inferior e 2J por vestibular dos caninos superiores e para o canino superior por palatino o protocolo foi: Potência de 70mW; densidade de energia de 35J/cm2; 20 segundos por ponto; 1,4J de energia por ponto, energia total de 7J. A retração durou 3 meses, num total de 3 aplicações de laser. Foi obtido um par de modelo de gesso inicial após as extrações dentárias e mensalmente antes da aplicação do laser que posteriormente foram escaneados com scanner 3Shape Ortho SystemTM \"(3ShapeTM Copenhagen, Dinamarca) e as imagens tridimensionais avaliadas por meio do software OrthoAnalyzer (3Shape) para mensuração da quantidade de movimentação dos caninos retraídos. Os pacientes preencheram uma escala visual após 12, 24, 48 e 72 horas da ativação da retração inicial dos caninos para avaliação da sensibilidade dolorosa. Para comparação da velocidade da movimentação ortodôntica e o nível de dor entre os lados irradiado e não irradiado nos três períodos avaliados, foi utilizado a Análise de Variância a um critério de medidas repetidas. Em todos os testes adotou-se nível de significância de 5%. Os resultados demonstraram diferença estatisticamente significante entre a quantidade de retração dos caninos irradiados comparados aos caninos não irradiados somente para os caninos inferiores no primeiro mês de aplicação do LBI. Em relação à sensibilidade dolorosa o LBI não foi efetivo em nenhum dos tempos avaliados. Concluiu-se assim que o LBI no protocolo utilizado só foi eficiente na aceleração da movimentação dentária dos caninos inferiores no primeiro mês de aplicação, porém não gerou redução da dor experimentada pelos pacientes frente às forças ortodônticas. / It was analyzed the orthodontic tooth movement and painful sensibility of maxilary and mandibular canine teeth submitted to irradiation with low-level laser (LLL) in an only monthly dose, compared to the non-irradiated contralateral canines (control). Eleven individuals with Class I malocclusion with indication of extraction of the first maxillary and mandibular premolars were selected. The low-level laser was applied after the activation of initial retraction of the canine teeth, performed with Niti coil springs with force of 150g. The laser application was performed in 10 points (5 buccal and 5 lingual) in the maxillary and mandibular canines, using the following protocol: Mandibular canine buccal and lingual and maxillary canine buccal: 40mW power; an energy density of 10 J/cm2; 10 seconds per point; energy per point 0,4J, a total energy of 4J applying to the mandibular canine and 2J the buccal of the maxillary canines and maxillary canine palatally: 70mW of power; an energy density of 35J/cm2; 20 seconds per point; 1,4J energy per point, the total energy 7J. The retraction lasted three months, a total of three laser applications. It was obtained a couple of dental casts after dental extractions and monthly model before applying the laser which were subsequently scanned with scanner \"3Shape\'s Ortho SystemTM\" (3ShapeTM - Copenhagen, Denmark) and three-dimensional images evaluated through OrthoAnalyzer software (3Shape) to measure the amount of movement of canines retracted. Patients completed a visual scale after 12, 24, 48 and 72 hours of initial activation of canine retraction for evaluation of pain sensitivity. To compare the speed of orthodontic tooth movement and the level of pain between the irradiated and non-irradiated sides at the three movement stages, repeated measures one-way analysis of variance was used. In all tests we adopted a significance level of 5%. The results showed statistically significant difference between the amount of retraction of the irradiated canines compared to the non-irradiated ones only for the mandibular canines in the first month of application of LLL. Regarding the soreness LLL was not effective in anytime evaluated. It was therefore concluded that LLL in the protocol used was effective only in the acceleration of tooth movement of the mandibular canines in the first month of application, but it did not cause reduction of pain experienced by patients ahead to orthodontic forces.
24

Fotoengenharia do processo de reparo ?sseo induzido pela laserterapia de baixa pot?ncia (GaAlAs) : estudo em f?mures de ratos

Guimar?es, Karis Barbosa 04 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:29:34Z (GMT). No. of bitstreams: 1 385866.pdf: 4321454 bytes, checksum: 8576f020eccaafd271cca4af5b4d883c (MD5) Previous issue date: 2006-12-04 / O presente estudo teve por objetivo avaliar, por meio de an?lise histol?gica e morfom?trica, a biomodula??o do processo de reparo ?sseo nas regi?es de peri?steo, end?steo e medula ?ssea de cavidades confeccionadas em f?mures de ratos, submetidas ? radia??o com laser diodo infravermelho (GaAlAs). Foram utilizados 30 ratos machos da linhagem Wistar, com peso entre 350 a 550 gramas, distribu?dos aleatoriamente em dois grupos, o controle (GI) e o experimental (GII), e seis subgrupos de acordo com o per?odo de observa??o dos animais. Para os grupos controle e experimental destinaram-se 13 e 14 animais, respectivamente. Os subgrupos experimentais receberam a terapia laser de baixa pot?ncia (LLLT), em um defeito ?sseo considerado experimental, identificado por meio de um parafuso de tit?nio, fixado, previamente, a 8mm do mesmo. No grupo GI todo o protocolo cir?rgico foi realizado, por?m sem a aplica??o do laser. No grupo GII foi utilizado o laser infravermelho ("lambda"= 830 nm, 6 J/cm2, 50mW, 120 s) de forma pontual e cont?nua. O protocolo de radia??o foi estabelecido com intervalos de 48horas, iniciando-se imediatamente ap?s a confec??o do defeito ?sseo, na cavidade medular. Os animais foram mortos aos 07, 15 e 21 dias. Para an?lise histol?gica, executou-se o processamento de rotina para as t?cnicas de HE e picros?rius. As l?minas foram estudadas segundo an?lise descritiva e morfom?trica. Os fen?menos teciduais avaliados, na an?lise descritiva, inclu?ram a resposta inflamat?ria e a neoforma??o ?ssea. Para a an?lise morfom?trica determinaram-se as m?dias de trabeculado ?sseo neoformado al?m das devidas localiza??es anat?micas destes trabeculados. Os resultados obtidos demonstraram que, nos grupos em que o laser foi aplicado na loja cir?rgica (GII), a atividade de remodela??o ?ssea foi quatitativamente maior quando comparada ? dos grupos GI, com maior matura??o da matriz ?ssea org?nica e padr?es de osteog?nese em est?gios mais avan?ados, nos per?odos iniciais do experimento. Al?m disso, segundo a an?lise morfom?trica, a biomodula??o ?ssea positiva evidenciada nos grupos GII apresentou maior m?dia de trabeculado ?sseo quando comparada aos grupos n?o submetidos ? LLLT. O mapeamento morfom?trico evidenciou a produ??o de est?mulos biomoduladores positivos apenas na localiza??o de peri?steo, denotando assim, maior potencial de penetra??o, estimula??o e acelera??o da consolida??o ?ssea na regi?o cortical do defeito ?sseo. Os resultados permitiram concluir que, a laserterapia de baixa pot?ncia no protocolo estabelecido atua como biomoduladora ?ssea em regi?o de peri?steo, podendo ser utilizada como coadjuvante no processo de reparo ?sseo.
25

An?lise do efeito da laserterapia na incorpora??o de aloenxertos ?sseos em blocos processados por congelamento profundo : estudo em coelhos

Valiati, Renato 11 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:55Z (GMT). No. of bitstreams: 1 431499.pdf: 9135185 bytes, checksum: f582813177d93f41d7f068b6594f67b4 (MD5) Previous issue date: 2011-03-11 / Objetivo: o objetivo deste estudo foi analisar o efeito da laserterapia de baixa pot?ncia no processo de incorpora??o ?ssea de aloenxertos em bloco com congelamento profundo. Materiais e M?todos: foram utilizados 14 coelhos: dois coelhos como doadores do tecido ?sseo e 12 coelhos como receptores onde foram realizados aloenxertos e autoenxertos ?sseos em bloco na calv?ria. Foram divididos em grupos com tratamento com laserterapia de baixa pot?ncia (aloenxerto e autoenxerto) e grupos controles (aloenxerto e autoenxerto) sem irradia??o. Os animais foram mortos com 35 dias (n=6) e 70 dias (n=6). Os par?metros de energia empregados foram: aplica??o de laser de diodo (AsGaAl) comprimento de onda de 830 nm - 4 J/cm2 em quatro pontos sobre os blocos de enxertos perfazendo um total de 16 J/cm2 por aplica??o. A dose total do tratamento ap?s as oito aplica??es foi de 128 J/cm2. Resultados: o aloenxerto ?sseo processado por congelamento profundo associado ? laserterapia de baixa pot?ncia apresentou incorpora??o na interface com o hospedeiro, remodela??o ?ssea moderada, preenchimento parcial das lacunas osteoc?ticas, menor infiltrado inflamat?rio nos per?odos iniciais e maior deposi??o de fibras col?genas quando comparado ao grupo controle. Conclus?o: o aloenxerto ?sseo processado por congelamento profundo associado ? laserterapia de baixa pot?ncia ? adequado como uma alternativa para o tratamento de defeitos ?sseos. O processamento do osso al?geno pelo m?todo de congelamento profundo mant?m as caracter?sticas estruturais e de osteocondu??o do tecido ?sseo.
26

Efeitos do laser de baixa pot?ncia na incorpora??o de aloenxerto ?sseo triturado

Paes, Jefferson Viapiana 17 May 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:14Z (GMT). No. of bitstreams: 1 439672.pdf: 3140896 bytes, checksum: adaf0986dd0bf8d5dad87d65250f73f6 (MD5) Previous issue date: 2012-05-17 / Objective: As the use of bone allografts in oral rehabilitation has increased, this study evaluated the effect of non-ablative laser on bone apposition when ground bone allografts are used. Studies in the literature show that the application of low-level laser therapy (LLLT) promotes tissue repair and new bone formation. Material and Methods: Four rabbits were used as bone donors, and ground bone allografts and autografts were implanted in the skull of 20 rabbits divided into four groups: two LLLT groups (allograft, autograft and blood clot), and two control groups (allograft, autograft and blood clot) that did not receive LLLT. The animals were killed at 35 (n=10) and 70 (n=10) days. Laser parameters were: laser diode application (GaAlAs), wavelength of 830 nm of 4 J/cm2 at four points in the skullcap at a total of 16 J/cm2 per application. Total treatment dose after eight applications was 128 J/cm2. Results: There was an increase in the apposition of collagen fibers, bone remodeling and vascularization, and there was less inflammatory infiltrate in the LLLT groups that received allografts at 35 days than in the allograft control group. At 70 days there was greater collagen fiber apposition, greater density of osteocytes lacunae, and a statistically significant difference in bone remodeling and vascularization when compared with the allograft control group. In the LLT autograft groups, there was also greater density of osteocytes lacunae, greater apposition of collagen fibers and greater bone remodeling at 35 and 70 days. Conclusion: Evaluation under light microscopy and SEM revealed a positive qualitative and quantitative effect of LLLT, which accelerated osteogenesis and the incorporation and remodeling of ground bone allografts and autografts / Objetivo: devido ao aumento da utiliza??o de aloenxertos ?sseos nas reabilita??es orais avaliou-se o efeito do laser n?o ablativo no processo de incorpora??o ?ssea de aloenxertos triturados. As pesquisas publicadas demonstram que aplica??o da laserterapia n?o ablativa (LLLT) apresenta vantagens no reparo tecidual e no processo de neoforma??o ?ssea. Materiais e M?todos: foram utilizados quatro coelhos como doadores do tecido ?sseo e realizados aloenxertos e autoenxertos triturados na calv?ria de 20 coelhos divididos em quatro grupos: dois grupos com LLLT (aloenxerto, autoenxerto e co?gulo sangu?neo) e outros dois grupos controle (aloenxerto, autoenxerto e co?gulo sangu?neo) sem irradia??o. Os animais foram mortos com 35 dias (n=10) e 70 dias (n=10). Os par?metros de energia empregados foram: aplica??o de laser de diodo (AsGaAl), comprimento de onda de 830 nm de 4 J/cm2 em quatro pontos da calota craniana perfazendo um total de 16 J/cm2 por aplica??o. A dose total do tratamento ap?s as oito aplica??es foi de 128 J/cm2. Resultados: houve um aumento da deposi??o de fibras col?genas, da remodela??o ?ssea, vasculariza??o e um menor infiltrado inflamat?rio nos grupos irradiados nos aloenxertos aos 35 dias quando comparado ao grupo controle al?geno. Aos 70 dias houve uma maior deposi??o de fibras col?genas e maior preenchimento das lacunas osteoc?ticas e foi observado diferen?a estat?stica significante na remodela??o ?ssea e na vasculariza??o quando comparado ao grupo controle al?geno. Os grupos de autoenxerto com LLLT apresentaram maior preenchimento das lacunas osteoc?ticas, maior deposi??o de fibras col?genas e maior remodela??o ?ssea aos 35 e 70 dias. Conclus?o: Observou-se atrav?s da Microscopia ?ptica e de MEV um efeito positivo qualitativo e quantitativo da LLLT, acelerando o processo de osteog?nese, incorpora??o e remodela??o de aloenxertos e autoenxertos ?sseos triturados
27

Avalia??o do coeficiente de atenua??o e da penetra??o de lasers de 682 685 nm e 826-829 nm pelo tecido ?sseo humano atrav?s de espectrorradiometria

Abreu, Marcelo Emir Requia 09 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:17Z (GMT). No. of bitstreams: 1 386622.pdf: 8591467 bytes, checksum: ed9eba44f55cbf4c0707a1758c121da0 (MD5) Previous issue date: 2007-01-09 / Lasers em baixas densidades de pot?ncia s?o empregados na terap?utica do tecido ?sseo e de estruturas adjacentes. Entretanto, seus efeitos biol?gicos dependem das propriedades ?pticas da intera??o da radia??o com o tecido alvo, as quais s?o correlacionadas aos par?metros f?sicos do meio e da luz laser. Portanto, realizou-se um trabalho com objetivo de avaliar a intera??o dos lasers com o tecido ?sseo humano seco, atrav?s da determina??o dos coeficientes de atenua??o e da penetra??o dos lasers de diodo na regi?o vis?vel e do infravermelho pr?ximo do espectro eletromagn?tico nesse tecido. Foram confeccionadas tr?s pe?as ?sseas da regi?o do corpo de mand?bulas humanas secas distintas, com espessura m?dia total de 0,0744 m. As amostras foram fatiadas em blocos de espessura m?dia de 0,0402 m e irradiadas com laser vermelho (I 682-685 nm), cont?nuo, pontual, em contato e com irradi?ncias de 8,679 Wm-2, 10,481 Wm-2 e 14,946 Wm-2; o mesmo foi realizado com o laser infravermelho (I 826-829 nm) com irradi?ncias de 9,854 Wm-2, 18,278 Wm-2 e 28,440 Wm-2. Ao longo do experimento os blocos foram sendo sucessivamente retirados e as amostras irradiadas, tornando poss?vel a irradia??o sob diferentes espessuras de tecido. Os dados foram obtidos por espectrorradiometria direta e analisados no programa Origin 7.0? atrav?s de equa??es de ajuste a esse modelo experimental. Os resultados obtidos demonstraram as seguintes tend?ncias: a transmiss?o dos lasers vermelho e infravermelho possuem rela??o inversamente proporcional ? espessura do tecido irradiado; o coeficiente de atenua??o do tecido ?sseo aos lasers ? inversamente proporcional ? irradi?ncia incidente; a penetra??o dos lasers possuem rela??o inversamente proporcional ? irradi?ncia e n?o altera-se significativamente em fun??o da irradi?ncia e sim em fun??o do comprimento de onda; o laser na regi?o do infravermelho possui um menor coeficiente de atenua??o e uma maior penetra??o em rela??o ao vermelho. Pode-se concluir que os valores do coeficiente de atenua??o e a penetra??o dos lasers na regi?o do vermelho de I 682 - 685 nm e do infravermelho de I 826 - 829 nm do espectro eletromagn?tico na regi?o de corpo de mand?bula humana seca, s?o principalmente determinados pelas caracter?sticas ?pticas e morfol?gicas do tecido, n?o sendo poss?vel a determina??o de um padr?o ?nico de intera??o laser/tecido, e sim tend?ncias
28

Influência de diferentes doses e número de aplicações do laser em baixa intensidade no reparo de defeitos ósseos em calvária de ratas Wistar com modelo experimental para a osteoporose / Influence of different doses and different number sessions of low-level laser irradiation in the repair of bone defects in calvaria of Wistar female rats model of osteoporosis

Scalize, Priscilla Hakime 28 November 2014 (has links)
A laserterapia em baixa intensidade (LLLI) é uma nova metodologia com comprovada eficácia na formação e na diminuição da reabsorção óssea, porém ainda não existe uma padronização quanto à sua utilização, sendo, portanto, necessários mais estudos para investigar o efeito de diferentes parâmetros como o comprimento de onda, duração da aplicação e número de sessões. Este estudo teve por objetivo avaliar os efeitos da LLLI em defeitos ósseos críticos em calvária de ratas Wistar com modelo experimental para osteoporose. A qualidade do tecido ósseo neoformado foi analisada por meio da microscopia de luz, e por meio da estereologia, foram estimados os seguintes parâmetros: volume do tecido de reparação do defeito (Vtr - μm3), densidade de volume das trabéculas (Vvt), volume total das trabéculas ósseas neoformadas (Vtot - μm3), densidade numérica de osteócitos (Nvost - μm-3), número total de osteócitos (Ntoost), volume médio dos osteócitos (Vnost - μm3), densidade de superfície das trabéculas (Svt - μm-1) e superfície de área das trabéculas (Sαt - μm2). A quantidade total de colágeno também foi analisada (Ac - μm2). Foram utilizadas 54 ratas que foram submetidas à ovariectomia bilateral. Após 150 dias, foram realizados defeitos ósseos na calvária. Os animais foram divididos em 9 grupos (n=6) e 24 horas após a confecção do defeito iniciou-se o tratamento com laser de Arseneto Gálio-Alumínio (AsGaAl; 780 nm). Os Grupos 1, 2 e 3 (G1, G2 e G3) receberam a dose ou densidade de energia de 0 J/cm2, 20 J/cm2 e 30 J/cm2 respectivamente, por 3 sessões; os grupos 4, 5 e 6 (G4, G5 e G6) receberam 0 J/cm2, 20 J/cm2 e 30 J/cm2 respectivamente, por 6 sessões e os grupos 7, 8 e 9 (G7, G8 e G9) receberam 0 J/cm2, 20 J/cm2 e 30 J/cm2 respectivamente, por 12 sessões. Comparando os grupos G2 e G1 os resultados estereológicos foram significantes para Vtr (p=0,023), Vvt (p=0,003), Vtot (p=0,04), Ntoost (p=0,048), Svt (p=0,000), Sαt (p=0,001) e Ac (p=0,000). Na comparação de G3 e G1 encontrou-se resultados significantes para Vvt (p=0,002) e Vtot (p=0,02). Na comparação de G5 e G4 os resultados foram significantes para Svt (p=0,041) e Sαt (p=0,043) e na comparação de G6 e G4 os resultados foram significantes para Vtr (p=0,005), Vvt (p=0,000), Vtot (p=0,000), Nvost (p=0,025), Ntoost (p=0,011), Svt (p=0,034), Sαt (p=0,028) e Ac (p=0,001). A comparação de G8 e G7 mostrou que a Sαt foi significante (p=0,047) e na comparação entre G9 e G7 os resultados foram significantes para Vtr (p=0,014), Vvt (p=0,000), Vtot (p=0,000), Nvost (p=0,025), Ntoost (p=0,024), Svt (p=0,042), Sαt (p=0,014) e Ac (p=0,023). Pôde-se concluir que houve neoformação óssea nos grupos que receberam as doses de 20 e 30 J/cm2 quando comparados com os respectivos grupos controles, porém, ao longo do tempo, a dose de 30 J/cm2 mostrou parâmetros estereológicos melhores quando comparada à dose de 20 J/cm2 / Low-level laser irradiation (LLLI) is a new methodology with proven clinical benefits in increased formation and decreased resorption of bone, however, the use of LLLI still needs to be clarified and standardized. Therefore, more studies are needed to analyze the effects of different parameters, such as wavelength, duration of application and number of sessions. This study aimed to assess the effects of LLLI on critical bone defects in rat calvaria used as an experimental model of osteoporosis. Light microscopy was used to analyze the quality of newly formed bone tissue and stereology was used to calculate the following parameters: tissue repair volume (Vtr - μm3), volume density of trabecular bone (Vvt), total volume of newly formed trabecular bone (Vtot - μm3), numerical density of osteocytes (Nvost - μm-3), total number of osteocytes (Ntoost), mean volume of osteocytes (Vnost - μm3), surface density of trabecular bone (Svt - μm-1) and area surface of trabecular bone (Sαt - μm2). The total amount of collagen was also examined (Ac - μm2). Fifty-four Wistar rats were subjected to bilateral ovariectomy. The bone defects were created in calvaria after 150 days. The animals were divided into 9 groups (n=6) and 24 hours after creating the defect, the treatment started with 780nm low intensity gallium-aluminum-arsenide (GaAlAs) laser: Groups 1, 2 and 3 (G1, G2 and G3) received the energy density of 0 J/cm2, 20 J/cm2 and 30 J/cm2 respectively, in 3 sessions; Groups 4, 5 and 6 (G4, G5 and G6) received 0 J/cm2, 20 J/cm2 and 30 J/cm2 respectively, in 6 sessions; Groups 7, 8 and 9 (G7, G8 and G9) received 0 J/cm2, 20 J/cm2 and 30 J/cm2 respectively, in 12 sessions. For the comparison between groups G2 and G1, the results obtained were significant for Vtr (p=0,023), Vvt (p=0,003), Vtot (p=0,04), Ntoost (p=0,048), Svt (p=0,000), Sαt (p=0,001) and Ac (p=0,000). For the comparison between G3 and G1, the results were significant for Vvt (p=0,002) and Vtot (p=0,02). For the comparison between G5 and G4, the results were significant for Svt (p=0,041) and Sαt (p=0,043) and for the comparison between G6 and G4, the results were significant for Vtr (p=0,005), Vvt (p=0,000), Vtot (p=0,000), Nvost (p=0,025), Ntoost (p=0,011), Svt (p=0,034), Sαt (p=0,028) and Ac (p=0,001). The comparison between G8 and G7 was significant for Sαt (p=0,047) and for the comparison between G9 and G7, the results were significant for Vtr (p=0,014), Vvt (p=0,000), Vtot (p=0,000), Nvost (p=0,025), Ntoost (p=0,024), Svt (p=0,042), Sαt (p=0,014) and Ac (p=0,023). In conclusion, there was new bone formation in the groups that received doses of 20 and 30 J/cm2 when compared with the respective control groups, but over time, the dose of 30 J/cm2 showed better stereological parameters when compared to 20 J/cm2
29

Efeito da laserterapia de baixa pot?ncia no reparo tecidual p?s exodontia em ratos submetidos a terapia com ?cido zoledr?nico e dexametasona / Effect of low level laser therapy on tissue repair post teeth extraction in rats submitted to zoledronic acid and dexamethasone therapy

Camilotti, Renata Stifelman 18 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-08-11T14:06:57Z No. of bitstreams: 1 DIS_RENATA_STIFELMAN_CAMILOTTI_PARCIAL.pdf: 1706843 bytes, checksum: 86f835b84ad4c9c1d525adc199226ade (MD5) / Made available in DSpace on 2016-08-11T14:06:57Z (GMT). No. of bitstreams: 1 DIS_RENATA_STIFELMAN_CAMILOTTI_PARCIAL.pdf: 1706843 bytes, checksum: 86f835b84ad4c9c1d525adc199226ade (MD5) Previous issue date: 2016-03-18 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The objectives of this study were: (a) elucidate whether Low Level Laser Therapy has positive effects in the treatment of bisphosphonate-related osteonecrosis of the jaw, by a systematic review of the literature. A systematic search of the PubMed, EMBASE, and Cochrane Library electronic databases was conducted, with no restrictions on language or year of publication. Search strategies were formulated using keywords and Boolean operators. The electronic search strategy retrieved 55 records. From 55 articles of wich 10 were ultimately included for data analysis in this review. Our findings show that treatment modalities including laser was associated with superior outcomes in terms of cure or improvement of bisphosphonate-related osteonecrosis of the jaw lesions as compared with conventional surgical and/or conservative drug therapy. It can be concluded that combined treatment with antibiotics, minimally invasive surgery (including Er:YAG laser surgery), and Low Level Laser Therapy in the early stages of the disease should be the gold standard for bisphosphonate-related osteonecrosis of the jaw management. (b) evaluate the influence of Low Level Laser Therapy in the 685nm and and 830nm wavelength (emission of red and infrared light repectivamente) in the healing process of the bone and soft tissues in rats under bisphosphonate therapy, zoledronic acid, and dexamethasone concomitantly underwent a surgery for extraction of upper molars. For this study were used twenty-eight Rattus norvegicus Wistar race, randomly divided into 4 groups of 7 animals each, one vehicle control group, a medication control group (administered Zoledronic Acid and dexamethasone) and other 2 groups wich were administered Zoledronic Acid and dexamethasone, one group was treatede with a laser with red light emission and the another onde with the and infrared light emission. There were statistically significant differences in the clinical evaluation of the wound and the weight of the animals. Regarding the histological evaluation, there were no statistically significant differences, although there are differences in the descriptions of the groups because it was possible to observe the difference maturation of the healing stage between groups. The effect of drug therapy with Zoledronic Acid and dexamethasone in the bone tissue repair process, induce osteonecrosis of the jaw in rats and slows down the healing process and we had positive influence on the bone and soft tissue repair process in the laser groups with red and infrared light emission at the stipulated dosimetry. / Os objetivos deste estudo foram: (a) tentar elucidar, atrav?s de revis?o sistem?tica da literatura, se a laserterapia atua positivamente no tratamento da osteonecrose dos maxilares induzida por bisfosfonatos. Foi realizada uma busca sistem?tica das bases de dados eletr?nicas PubMed, Embase e Cochrane Library, sem restri??es de linguagem ou ano de publica??o. As estrat?gias de busca foram formuladas utilizando palavras-chave e operadores booleanos. A estrat?gia de busca eletr?nica encontrou 55 registros dos quais 10 foram finalmente inclu?dos para an?lise de dados nesta revis?o. Nossos resultados mostram que as modalidades de tratamento, incluindo o laser foi associado com resultados superiores em termos de cicatriza??o ou melhora de osteonecrose dos maxilares induzida por bisfosfonatos, em compara??o com a terapia com cir?rgica convencional e/ou conservadora com uso de medica??o. Pode-se concluir que o tratamento combinado com antibi?ticos, cirurgia minimamente invasiva (incluindo cirurgia a laser de Er: YAG), e a laserterapia de baixa pot?ncia nas fases iniciais da doen?a deve ser o padr?o ouro para osteonecrose dos maxilares induzida por bisfosfonatos; (b) avaliar a influ?ncia da laserterapia de baixa pot?ncia nos comprimendos de onda de 685nm e 830 nm (emiss?o de luz vermelha e infravermelha repectivamente) no processo de reparo dos tecidos ?sseo e mole em ratos sob terapia com bisfosfonato, no caso o ?cido Zoledr?nico, e Dexametasona concomitantemente submetidos a procedimento cir?rgico de exodontia dos molares superiores. Para essa pesquisa foram utilizados vinte e oito Rattus norvegicus da ra?a Wistar, aleatoriamente divididos em 4 grupos de 7 animais cada, sendo um grupo controle ve?culo, um grupo controle da medica??o (administrado ?cido Zoledr?nico e Dexametasona) e outros 2 grupos onde foram administrado ?cido Zoledr?nico e Dexametasona, sendo um grupo tratado com laser, com emiss?o de luz vermelha e outro, infravermelho. Houve diferen?as estatisticamente significativas na avalia??o cl?nica da ferida e no peso dos animais. Em rela??o ? avalia??o histol?gica, n?o houve diferen?as estatisticamente significativas, apesar de haver diferen?as nas descri??es entre os grupos, pois foi poss?vel observar a diferen?a de matura??o do est?gio de cicatriza??o entre os grupos. O efeito da terapia medicamentosa com o ?cido Zoledr?nico e Dexametasona concomitantes no processo de reparo dos tecidos ?sseo, induz a osteonecrose da maxila em ratos e retarda o processo de cicatriza??o e os efeitos da laserterapia com emiss?o de luz vermelha e infravermelha com a dosimetria estipulada teve influ?ncia positiva no processo de reparo de tecidos ?sseo e mole.
30

Avaliação de um vitrocerâmico elaborado a partir do genérico do biovidro 45S5 em perfurações de tíbias de ratos, e seu comportamento sob influência da radiação laser de baixa intensidade / Evaluation of a glass ceramic produced from the generic of bioglass 45S5 in drilling of tibias of rats, and their behavior under the influence of low-intensity laser radiation

Emiliano Rodrigo de Barros Arruda 26 August 2008 (has links)
O presente trabalho avaliou os efeitos provocados pela laserterapia de baixa intensidade (LTBI) no \'lâmbda\' 780 nm, 30 mW de potência e tempo de exposição de 150 segundos, resultando em uma fluência de 112,5 J/\'CM POT.2\' e energia total de 4,5 J, sobre o comportamento osteocondutor da vitrocerâmica elaborada a partir do genérico do biovidro de composição: 45% \'SI\'O IND.2\', 24,5% \'NA IND.2\'O\', 24,5% \'CA\'O\' e 6% \'P IND.2\'O IND.5\' em perfurações ósseas em tíbias de ratos. O biovidro foi recozido em cuba de inox acima de sua temperatura de transição vítrea, a 620 graus Celsius por 30 minutos e mantido a 790 graus Celsius por 60 minutos, em seguida foi realizada a espectroscopia Raman para verificar a cristalinidade. Foram realizadas perfurações abaixo da tuberosidade da tíbia direita de 64 machos de ratos da raça Wistar (Rattus norvegicus albinus) na idade adulta. Os mesmos foram divididos aleatoriamente em 4 grupos sendo eles: um controle e três submetidos à procedimento experimental de implante e/ou irradiação laser de baixa intensidade. Em todos os grupos foram utilizados 16 indivíduos. Posteriormente, os animais de cada grupo foram subdivididos em dois subgrupos cada, de acordo com o tempo de vida antes da eutanásia, que ocorreu com 7 e 13 dias P.O. A análise das características das fibras colágenas para determinar a neoformação tecidual, bem como seu estado de maturação, foi realizada através de corpos de prova em forma de lâminas coradas com HE observadas à microscopia de luz comum para verificar a presença de células no foco de lesão, lâminas coradas com Picro Sirius sob luz polarizada a fim de verificar o estado organizacional e microscopia eletrônica de varredura, utilizando métodos técnico-experimentais para avaliar a interação do biomaterial com o tecido ósseo. Os valores de birrefringência demonstraram uma melhor organização tecidual dos grupos irradiados com ou sem o implante de vitrocerâmico (p < 0,05), os grupos com vitrocerâmico apresentaram o tecido mais difuso, até mesmo nas regiões mais centrais da lesão aos 13 dias. O vitrocerâmico estimulou a proliferação osteoblástica (p < 0,05), assim como a radiação laser (p < 0,01). Pode-se concluir que o vitrocerâmico utilizado apresenta capacidade osteocondutora e que a radiação laser acelerou o processo de reparo na presença ou não do vitrocerâmico. / The present study evaluated the effects caused by the low level laser therapy (LLLT) at \'lâmbda\' 780 nm, power of 30 mW and dose of 112.5 J/\'CM POT.2\' and total energy of 4.5 J on the behavior osteoconductor of the glass-ceramic drafted from generic of bioglass of composition: 45% \'SI\'O IND.2\', 24.5% \'NA IND.2\'O\', 24.5% \'CA\'O\' and 6% \'P IND.2\'O IND.5\' in drillings in tibia bone of rats. The bioglass was anneal in cuba of stainless above its glass transition temperature, to 620 Celsius degrees for 30 minutes and maintained at 790 Celsius degrees for 60 minutes, then was held to Raman spectroscopy to verify the crystallinity. Drillings were made below the tuberosity of the right tibia of 64 males of the race Wistar rats (Rattus Norvegicus Albinus) in adult age. They were randomly divided into 4 groups which are: a control and three underwent experimental procedure to implant and/or of low intensity laser irradiation. In all groups were used 16 individuals. Later, the animals in each group were further divided into two subgroups each, according to the time of life before euthanasia, which occurs with 7 and 13 days postoperative. The analysis of the characteristics of collagen fibers was conducted through: slides stained with HE seen the light microscopy, to quantify the presence of cells in the focus of injury, slides stained with Picro Sirius Red under polarized light to verify the organizational state, microscope electronic scanning, using technical experimental methods to evaluate the interaction of biomaterial with the bone tissue. The values of birefringence showed better tissue organization of groups irradiated with or without the implant of glass-ceramic (p < 0.05), the groups with glass-ceramic showed collagen fibers more diffuse, even in the most central of injury to 13 days. The glass-ceramic stimulated the osteoblast proliferation (p < 0.05) as well as laser radiation (p < 0.01). Thus it is possible to conclude that the glass-ceramic has osteoconductive capacity and that laser radiation accelerated the process of repairing in the presence or not of glass-ceramic.

Page generated in 0.1137 seconds