• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 1
  • 1
  • Tagged with
  • 18
  • 14
  • 11
  • 11
  • 9
  • 9
  • 7
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Partículas de fosfato de ferro e fosfato de ferro-cálcio como dispositivos visando o tratamento de melanoma / not available

Schul, Vitor Basso 07 October 2010 (has links)
O câncer tem múltiplas origens e suas causas incluem estilo de vida, fatores ambientais e suscetibilidade genética hereditária. Por isso, a busca por tratamentos mais eficazes e por um diagnóstico precoce das neoplasias malignas cresce cada vez mais. Apesar de o câncer, geralmente, derivar de um único clone de células transformadas, o processo de progressão tumoral promove considerável diversidade genética entre as células neoplásicas em crescimento. O melanoma cutâneo maligno origina-se dos melanócitos presentes predominantemente na pele ou de células precursoras multipotentes, como os nevus, e é o câncer cutâneo com maior grau de malignidade. Várias são as linhas de tratamento utilizadas atualmente para o câncer, porém muitas ainda não são tão eficazes, e a descoberta precoce ainda é uma das principais ferramentas para o combate ao problema. O presente projeto teve como objetivo verificar a resposta de células de fibroblastos e Hep2 in vitro tratadas com partículas de óxido de ferro e ferro-cálcio, assim como, a caracterização dessas partículas. A caracterização das partículas foi realizada por meio da análise granulométrica, de Microscopia eletrônica de varredura (MEV), teste de absorbância dos vidros e a medida da capacidade de aquecimento das partículas quando em solução nas concentrações de 50, 250 e 500 mg/ml. Os testes de toxicidade dos vidros foram realizados por meio de ensaios in vitro de difusão de extratos em solução e método de difusão em Agar utilizando-se linhagem celular de fibroblasto e células tumorais de laringe humana Hep2. E, testes in vivo com a administração das partículas obtidas pela via subcutânea. Os resultados da caracterização das partículas demonstraram que o diâmetro médio das partículas de fosfato de ferro foi de 830,2 nm e 745,3 nm para as partículas de fosfato de ferro-cálcio, o que foi confirmado pela MEV. O teste de absorbância mostrou que os vidros absorvem em ampla faixa do espectro eletromagnético, incluindo a faixa de 660 nm. O teste de aquecimento demonstrou a capacidade das partículas em variar em média 14 graus Celsius a temperatura da solução, independentemente da concentração utilizada. Os testes in vitro e in vivo mostraram que as partículas não foram citotóxicas e não causaram danos ao tecido subcutâneo, mesmo após o tempo de 1 semana da administração. Estes resultados mostram que a utilização de partículas de vidros de fosfato para o tratamento de câncer pode ser viável, assim com seu potencial para utilização no tratamento de melanoma. / Cancer has many origins and their causes include lifestyle, environmental factors and hereditary susceptibility. Therefore, the search for better treatments and early diagnosis of malignant neoplasms grows more and more. Although the cancer usually derives from a single clone of transformed cells, the process of tumor progression promotes genetic diversity between the neoplastic cells in growth. Cutaneous malignant melanoma arises from melanocytes predominantly present in the skin or multipotent progenitor cells, such as nevi, and is the skin cancer with the highest degree of malignancy. Several lines of treatment are currently used to treat the cancer, but many still not effective and early detection stills one of the main tools to combat the problem. This project aimed to verify the response of fibroblasts and Hep2 cells treated in vitro with particles of iron oxide and iron-calcium, as well as the characterization of these particles. Characterization of particles was performed by means of textural analysis, scanning electron microscopy (SEM), absorbance test of the glasses and measurement of the heating capability in particle solutions at concentrations of 50, 250 and 500 mg/ml. Toxicity tests of glasses were performed using in vitro tests of extracts of diffusion in solution and Agar diffusion method using a fibroblast cell line and tumor cells in Hep2 human larynx. And, in vivo tests with subcutaneous injection of the particles. The characterization results showed that the particle average diameter of particles of iron phosphate was 830.2 nm and 745.3 nm for the particles of iron-calcium phosphate, which was confirmed by SEM. The absorbance test showed that the glasses absorb in a wide range of the electromagnetic spectrum, including the band of 660 nm. The heating test demonstrated the capability of the particles to promote a 14ºC average temperature variation in the solution, regardless of the concentration. In vitro and in vivo tests showed that the particles were not cytotoxic and did not cause damage to the subcutaneous tissue, even after 1 week of administration. These results shows that the utilization of phosphate glasses particles can be feasible, as well as its potential for use in the treatment of melanoma.
2

Porovnání fyzikální terapie Trigger points v horní porci musculus trapezius pomocí ultrasonoterapie a fototerapie laserem / Comparison of physical therapy of trigger points in the upper portion of the trapezius muscle using ultrasonotherapy and laser phototherapy

Krulík, Jan January 2012 (has links)
The thesis is divided into theoretical and practical part. The theoretical part contains information about anatomy of the trapezius muscle and its myofascial pathology. Author further discusses trigger points, their histopathology and diagnostic and therapeutic capabilities. A significant section of the theoretical part explains the physical principle of ultrasound therapy and laser phototherapy, including clinical aspects and their use in the treatment of trigger points. The practical part is focused on comparing the efficacy and relative effectiveness of two methods of physical therapy - ultrasound therapy and laser phototherapy, where myofascial trigger points treatment effect can be expected. Research group is made up of 47 patients divided into two groups. These patients have a doctor confirmed trigger point in the upper portion of trapezius muscle. The first group of patients is treated by exactly parametrically defined ultrasound therapy. The second group of patients is treated by specifically defined laser phototherapy. The aim of this thesis is to compare the above mentioned physical procedures in terms of subjective and objective efficacy in the treatment of trigger points and also to compare their relative effectiveness.
3

Partículas de fosfato de ferro e fosfato de ferro-cálcio como dispositivos visando o tratamento de melanoma / not available

Vitor Basso Schul 07 October 2010 (has links)
O câncer tem múltiplas origens e suas causas incluem estilo de vida, fatores ambientais e suscetibilidade genética hereditária. Por isso, a busca por tratamentos mais eficazes e por um diagnóstico precoce das neoplasias malignas cresce cada vez mais. Apesar de o câncer, geralmente, derivar de um único clone de células transformadas, o processo de progressão tumoral promove considerável diversidade genética entre as células neoplásicas em crescimento. O melanoma cutâneo maligno origina-se dos melanócitos presentes predominantemente na pele ou de células precursoras multipotentes, como os nevus, e é o câncer cutâneo com maior grau de malignidade. Várias são as linhas de tratamento utilizadas atualmente para o câncer, porém muitas ainda não são tão eficazes, e a descoberta precoce ainda é uma das principais ferramentas para o combate ao problema. O presente projeto teve como objetivo verificar a resposta de células de fibroblastos e Hep2 in vitro tratadas com partículas de óxido de ferro e ferro-cálcio, assim como, a caracterização dessas partículas. A caracterização das partículas foi realizada por meio da análise granulométrica, de Microscopia eletrônica de varredura (MEV), teste de absorbância dos vidros e a medida da capacidade de aquecimento das partículas quando em solução nas concentrações de 50, 250 e 500 mg/ml. Os testes de toxicidade dos vidros foram realizados por meio de ensaios in vitro de difusão de extratos em solução e método de difusão em Agar utilizando-se linhagem celular de fibroblasto e células tumorais de laringe humana Hep2. E, testes in vivo com a administração das partículas obtidas pela via subcutânea. Os resultados da caracterização das partículas demonstraram que o diâmetro médio das partículas de fosfato de ferro foi de 830,2 nm e 745,3 nm para as partículas de fosfato de ferro-cálcio, o que foi confirmado pela MEV. O teste de absorbância mostrou que os vidros absorvem em ampla faixa do espectro eletromagnético, incluindo a faixa de 660 nm. O teste de aquecimento demonstrou a capacidade das partículas em variar em média 14 graus Celsius a temperatura da solução, independentemente da concentração utilizada. Os testes in vitro e in vivo mostraram que as partículas não foram citotóxicas e não causaram danos ao tecido subcutâneo, mesmo após o tempo de 1 semana da administração. Estes resultados mostram que a utilização de partículas de vidros de fosfato para o tratamento de câncer pode ser viável, assim com seu potencial para utilização no tratamento de melanoma. / Cancer has many origins and their causes include lifestyle, environmental factors and hereditary susceptibility. Therefore, the search for better treatments and early diagnosis of malignant neoplasms grows more and more. Although the cancer usually derives from a single clone of transformed cells, the process of tumor progression promotes genetic diversity between the neoplastic cells in growth. Cutaneous malignant melanoma arises from melanocytes predominantly present in the skin or multipotent progenitor cells, such as nevi, and is the skin cancer with the highest degree of malignancy. Several lines of treatment are currently used to treat the cancer, but many still not effective and early detection stills one of the main tools to combat the problem. This project aimed to verify the response of fibroblasts and Hep2 cells treated in vitro with particles of iron oxide and iron-calcium, as well as the characterization of these particles. Characterization of particles was performed by means of textural analysis, scanning electron microscopy (SEM), absorbance test of the glasses and measurement of the heating capability in particle solutions at concentrations of 50, 250 and 500 mg/ml. Toxicity tests of glasses were performed using in vitro tests of extracts of diffusion in solution and Agar diffusion method using a fibroblast cell line and tumor cells in Hep2 human larynx. And, in vivo tests with subcutaneous injection of the particles. The characterization results showed that the particle average diameter of particles of iron phosphate was 830.2 nm and 745.3 nm for the particles of iron-calcium phosphate, which was confirmed by SEM. The absorbance test showed that the glasses absorb in a wide range of the electromagnetic spectrum, including the band of 660 nm. The heating test demonstrated the capability of the particles to promote a 14ºC average temperature variation in the solution, regardless of the concentration. In vitro and in vivo tests showed that the particles were not cytotoxic and did not cause damage to the subcutaneous tissue, even after 1 week of administration. These results shows that the utilization of phosphate glasses particles can be feasible, as well as its potential for use in the treatment of melanoma.
4

Estudo do efeito deletério do iodo-131 nas glândulas salivares de camundongos tratados ou não com laser de baixa potência / Study of Iodine-131 ablation effects in mice salivary glands treated and not treated with low-power laser irradiation

Magliano, Gabriela Campos 14 February 2019 (has links)
O tratamento com o iodo-131, conhecido como iodoterapia, já é bem estabelecido para tumores de tireoide diferenciados, porém, pode ter como importante efeito colateral o desenvolvimento da hipofunção das glândulas salivares. Dados recentes da literatura relatam casos de sialoadenite e xerostomia em pacientes submetidos à iodoterapia, no entanto, poucos estudos analisam o seu efeito na função e morfologia do tecido glandular, o que dificulta o aparecimento de métodos preventivos e curativos para essas complicações. Com isso e baseado em estudos que indicam resultados promissores da terapia fotobiomoduladora, com laser de baixa potência, no tratamento da hipofunção das glândulas salivares; este trabalho teve como objetivo compreender o efeito da iodoterapia sobre as glândulas salivares e analisar se a terapia de fotobiomodulação é capaz de evitar o dano ao tecido. Para isto, foi estabelecido o protocolo de indução da hipofunção das glândulas salivares através da iodoterapia em 70 camundongos BALB/c; os quais foram divididos em três grupos: C, controle (n=30); I, submetidos à iodoterapia (n=20); e IL, submetidos à iodoterapia e terapia fotobiomoduladora para a hipofunção das glândulas salivares (n=20), com um comprimento de onda de 808 nm, espectro infravermelho, potência de 100 mW, energia de 1 J e 10 s por ponto, totalizando uma densidade de energia de 35,7J/cm². Os animais foram avaliados em três tempos experimentais; T1: antes da iodoterapia, T2: 10 dias após a iodoterapia, e T3: 90 dias após a iodoterapia. Logo após a eutanásia, houve a remoção das glândulas salivares parótidas e submandibulares, para análises morfológicas e imuno-histoquímicas, para a determinação quantitativa de células apoptóticas e expressão dos canais de sódio e iodo, cujos resultados mostraram que a iodoterapia com o iodo-131 promoveu, nas glândulas salivares parótida e submandibular, a inibição dos canais de sódio e iodo, aumento de células apoptóticas e alteração do estroma glandular, com diminuição na concentração de colágeno e atrofia das unidades secretoras terminais. Além disso, também foi observado que a TFBM com laser de baixa potência foi eficaz na modulação dos efeitos inflamatórios causados pelo iodo-131, aumentando a produção de colágeno no tecido glandular, modulando a inflamação nas unidades secretoras terminais, reativando expressão do NIS e controlando a apoptose celular. Com os resultados obtidos no presente estudo, concluímos que que a iodoterapia causa hipofunção das glândulas salivares parótidas e submandibulares e que a terapia de fotobiomodulação se mostrou uma terapia eficaz e promissora para prevenir e atenuar estes efeitos colaterais. / Radioiodine treatment (RI), is a usual treatment for thyroid tumours, which may have the salivary gland hypofunction (SGH) as an important side effect. Sialoadenitis and xerostomia were reported in patients submitted to RI, however, only a few studies have analyzed its effect on function and morphology of glandular tissue, which makes it difficult to discover preventive and curative methods for these complications. Based on this and on the positive effects of photobiomodulation therapy (PBMT) in the treatment of HGS, the aim of the present study was to understand the effect of RI on salivary glands and to examine whether the PBMT is capable of preventing tissue damage. Thus, the protocol of induction of SGH by RI was performed in 70 BALB / c mice; which were divided into three groups: C, control (n = 30); I, submitted to RI (n = 20); and IL, submitted to RI and PBMT (n = 20). The animals were analysed in three different experimental times; T1: before RI, T2: 10 days after RI, and T3: 90 days after RI. Shortly after euthanasia, the parotid and submandibular salivary glands, were surgically removed for morphological and immunohistochemical analyzes, for the quantitative determination of apoptotic cells and expression of the sodium and iodine channels. The data showed an inhibition of sodium and iodine channels, increase of apoptotic cells and alteration of the glandular stroma, with destruction of collagen and atrophy of the secretory units in salivary glands, after RI. It was also observed that the PBMT seems to have been effective in modulating the effects of this inflammatory condition, increasing collagen production in the glandular tissue, modulating inflammation in the terminal secretory units, reactivating NIS expression and controlling cellular apoptosis. In conclusion, the RI caused hypofunction of the parotid and submandibular salivary glands and the PBMT was able to prevent and attenuate this side effect.
5

Efeitos da aplicação do laser a diodo de arseneto de gálio (As-Ga) na osteoartrite experimental em coelhos / Effects of gallium arsenate (Ga-As) diodo laser on experimental ostheoarthritis in rabbits

Lobato, Danielle Andreazzi 15 December 2003 (has links)
Made available in DSpace on 2015-03-26T13:47:26Z (GMT). No. of bitstreams: 1 texto completo.pdf: 330178 bytes, checksum: 0d7d63bcceac97aa987ceb95abd2345a (MD5) Previous issue date: 2003-12-15 / The aim of this study was to evaluate the effects of gallium arsenite (Ga-As) diode laser application on rabbits knees with ostheoarthritis induced by intrarticular injection of carrageenan. Clinical evaluation in vivo showed that there was reduction in inflammatory signs and pain, with treated animals presenting a better performance and greater amplitude of movements, if compared with untreated animals. The degenerative processes resulting from the administration of carrageenan were evidenced in both groups by post-mortem macroscopic and microscopic assessment in both treated and control groups, which allowed inferring that laser diminished the presence of chemical mediators, reducing the inflammatory response and local lesions, including the degradation of glycosaminoglycans. Histological analysis of the synovial membrane revealed the presence of inflammatory cells distributed diffusely or in foci, the intensity of which was higher in control groups. It was concluded therefore that the rate of progression of ostheoarthritis was slowed down by lasertherapy. / O objetivo deste estudo foi avaliar os efeitos do laser a diodo de Arseneto de Gálio (As-Ga) aplicado no joelho de coelhos portadores de osteoartrite induzida pela aplicação intrarticular de carragenina. A avaliação clínica in vivo demonstrou diminuição dos sinais inflamatórios e da dor, permitindo melhor desempenho e maior amplitude de movimento do joelho dos coelhos tratados em comparação aos dos animais não tratados. A avaliação macroscópica e microscópica post-mortem evidenciaram os processos degenerativos decorrentes da administração de carragenina em ambos os grupos, tratado e controle. Os resultados permitiram inferir que o laser diminuiu a presença de mediadores químicos reduzindo, assim, a resposta inflamatória e as lesões locais, inclusive a degradação dos glicosaminoglicanos. A análise histológica da membrana sinovial demonstrou a presença de células inflamatórias, distribuídas difusamente ou em focos, em maior intensidade nos grupos controle. Concluiu-se, portanto, que o caráter progressivo da osteoartrite foi retardado pela laserterapia.
6

Avaliação da aplicação do laser de baixa potência com ou sem a associação de antimicrobiana em radiomucosite oral

Thais Benedetti Haddad Cappellanes 30 July 2008 (has links)
A radioterapia tem importante aplicação clínica no tratamento das neoplasias malignas de cabeça e pescoço. A mucosite oral causada pelo efeito das radiações ionizantes, nos tecidos normais, manifesta-se como processo inflamatório reativo, com alta prevalência e diferentes graus de envolvimento tecidual. Os avanços alcançados com os laseres de baixa potência, assim como o uso de alguns fármacos, indicam a possibilidade de adoção de uma estratégia eficaz na terapia da mucosite oral. O presente estudo teve como objetivo avaliar a aplicação do laser de baixa potência associado ou não ao uso de antimicrobiano tópico (clorexidina gel 0,2%) no tratamento da mucosite oral. Quatorze pacientes portadores de neoplasia maligna na região de cabeça e pescoço, com indicação de tratamento radio e ou radioquimioterápico foram alocados em dois grupos: Grupo I: laser e Grupo II: laser e clorexidina. Os pacientes foram submetidos a tratamento profilático e terapêutico durante oito semanas. O grau de severidade da mucosite foi avaliado pelo método da OMS e a dor pela escala visual analógica (EVA). Os resultados mostraram que não houve diferença significativa entre a aplicação do laser isolado ou associado ao uso do antimicrobiano tópico. A laserterapia promoveu redução da dor e do grau de severidade da mucosite oral induzida pela radioterapia. Novos estudos devem ser realizados com a finalidade de serem estabelecidos protocolos padronizados e efetivos na abordagem terapêutica da mucosite oral. / Radiotherapy has an important clinical role in the treatment of the malignant tumors of head and neck. Oral mucositis induced by radiotherapy is a reactive inflammatory process of the oral mucosae with high prevalence and different degrees of tissue involvement. The advances reached with low power lasers devices, as well as the use of some medicines, indicate the possibility of adoption of an efficient strategy in handling with the oral mucositis. The aim of the present study was to evaluate the application of the low power laser associated or not with topical antimicrobials use in oral mucositis treatment. Fourteen patients with head and neck cancer undergoing radiotherapy, with or not associated chemotherapy, were located in two groups: Group I: laser and Group II: laser and clorexidine. All the patients were submitted to prophylactic and therapeutical treatment during eight weeks. The grade and severity of mucositis was evaluated using the WHO scale and pain was measured by visual analogue scale (VAS). The study showed that there is not significant difference between the use of laser application only or associated with topical antimicrobials. Lasertherapy promoted decrease of the pain and the severity grade of oral mucositis induced by radiotherapy. New studies must be developed in order to establish standardized and effective protocols in oral mucositis management.
7

Terapia laser em baixa intensidade em pacientes portadores da Síndrome de Ardência Bucal: estudo randomizado e controlado / Low Level Light Therapy in Burning Mouth Syndrome patients: randomized and controlled trial

Pellegrini, Vivian Diane 11 November 2010 (has links)
A Síndrome de Ardência Bucal (SAB) é uma condição de etiologia ainda desconhecida, caracterizada por ardência em mucosa oral na ausência de qualquer sinal clínico, cujo tratamento ainda é insatisfatório. O objetivo deste estudo foi avaliar a eficácia terapêutica do laser em baixa intensidade para pacientes SAB, por meio de estudo controlado e randomizado. Vinte e três pacientes acometidos pela SAB atenderam aos critérios de inclusão, cumpriram o protocolo estabelecido e tiveram seus dados tabulados e analisados. Fizeram parte da avaliação inicial dos pacientes, exame clínico estomatológico completo, sialometria, exames hematológicos e avaliação psicológica voltada à identificação da qualidade de vida e de sinais de depressão. Constituíram-se dois grupos experimentais, que receberam quatro irradiações, duas por semana, de laser em baixa intensidade - grupo Laser, ou de falsa irradiação - grupo Placebo. O aparelho usado foi um laser em baixa intensidade (Quantum, EccoFibras, Campinas-Brasil) de AsGaAl, emitindo 790 nm e com 120 mW de potência. As irradiações foram realizadas na forma de varredura, nas áreas de mucosa acometidas pelo sintoma de ardência, fornecendo uma dose de 6 J/cm2. Os pacientes foram alocados entre os grupos segundo programa de randomização por computador, sendo mantidos cegos quanto ao tipo de irradiação recebida (laser ou placebo). Os resultados foram coletados por pesquisadora auxiliar, que não teve conhecimento do tipo de irradiação efetuada, por meio de escala visual analógica (VAS) e escala de percepção global (EPG). A pesquisadora principal não teve acesso aos resultados, antes do término do estudo. Os pacientes foram avaliados ao início do estudo, em cada um dos quatro tempos de irradiação e aos 7, 14, 30, 60 e 90 dias após a última irradiação. Os pacientes foram categorizados, de acordo com seu percentual de sintoma, ao final do último controle: sem ardência (S.A)- 0% de sintomatologia, ótimo (O)- 1% a 25%, bom (B)- 26%-50%, regular (R)- 51%-75%, inalterado (I)- 76-100% e piora (P)- valores superiores a 100%. A análise estatística apontou uma melhor resposta no grupo Laser (p=0,03; Teste Exato de Fisher). Concluiu-se que a terapia com laser em baixa intensidade, segundo o protocolo utilizado neste estudo, produz benefício aos pacientes portadores da síndrome de ardência bucal, sem apresentar qualquer efeito colateral indesejável, sugerindo o aprofundamento da pesquisa nesse campo. / Burning Mouth Syndrome (BMS) is a condition of unknown etiology, characterized by a burning sensation in the oral mucosa in the absence of any clinical sign, which treatment is still unsatisfactory. The aim of this study was to evaluate the effectiveness of low intensity laser therapy for SAB patients, through a randomized controlled clinical trial. Twenty-three patients affected by SAB met the inclusion criteria, complied with the established protocol and had their data analyzed. Patients initial evaluation comprised a complete clinical examination, unstimulated salivary flow, hematological examination and psychological assessment focused on identifying the quality of life and signs of depression. Two experimental patients groups were constituted: a Laser group and a Placebo group, which received four irradiations, two per week, of low intensity laser or false irradiation, respectively. The laser device utilized was a low intensity laser (Quantum, EccoFibras, Campinas, Brazil) GaAlAs, emitting 790 nm with120 mW of power. The irradiations were performed scanning the areas of mucosa affected by the burning sensation, delivering a dose of 6 J/cm2. Patients were allocated among the groups with the aid of a randomization computer program. Patients were kept blind to the type of radiation received (laser or placebo). The results were obtained by a researcher assistant, who was unaware of the type of irradiation effected, by means of a visual analogue scale (VAS) and a global perception scale (EPG). The principal investigator had access to the results only at the end of the study. Patients were evaluated at baseline in each of the four times of irradiation and at 7, 14, 30, 60 and 90 days after the last irradiation. Patients were categorized according to their percentage of symptom at the end of last control: no burning (SA) - 0% of symptoms, optimal (O) - 1% to 25%, good (B) - 26% -50 %, regular (R) - 51% -75%, unchanged (I) - 76-100%, and worsening (P) - values exceeding 100%. Statistical analysis showed a better response in the laser group (p = 0.03, Fisher\'s exact test). It was concluded that low intensity laser therapy, according to the protocol applied in this study, produces benefit to patients with burning mouth syndrome, without any undesirable side effect, suggesting further research in this field.
8

Terapia laser em baixa intensidade em pacientes portadores da Síndrome de Ardência Bucal: estudo randomizado e controlado / Low Level Light Therapy in Burning Mouth Syndrome patients: randomized and controlled trial

Vivian Diane Pellegrini 11 November 2010 (has links)
A Síndrome de Ardência Bucal (SAB) é uma condição de etiologia ainda desconhecida, caracterizada por ardência em mucosa oral na ausência de qualquer sinal clínico, cujo tratamento ainda é insatisfatório. O objetivo deste estudo foi avaliar a eficácia terapêutica do laser em baixa intensidade para pacientes SAB, por meio de estudo controlado e randomizado. Vinte e três pacientes acometidos pela SAB atenderam aos critérios de inclusão, cumpriram o protocolo estabelecido e tiveram seus dados tabulados e analisados. Fizeram parte da avaliação inicial dos pacientes, exame clínico estomatológico completo, sialometria, exames hematológicos e avaliação psicológica voltada à identificação da qualidade de vida e de sinais de depressão. Constituíram-se dois grupos experimentais, que receberam quatro irradiações, duas por semana, de laser em baixa intensidade - grupo Laser, ou de falsa irradiação - grupo Placebo. O aparelho usado foi um laser em baixa intensidade (Quantum, EccoFibras, Campinas-Brasil) de AsGaAl, emitindo 790 nm e com 120 mW de potência. As irradiações foram realizadas na forma de varredura, nas áreas de mucosa acometidas pelo sintoma de ardência, fornecendo uma dose de 6 J/cm2. Os pacientes foram alocados entre os grupos segundo programa de randomização por computador, sendo mantidos cegos quanto ao tipo de irradiação recebida (laser ou placebo). Os resultados foram coletados por pesquisadora auxiliar, que não teve conhecimento do tipo de irradiação efetuada, por meio de escala visual analógica (VAS) e escala de percepção global (EPG). A pesquisadora principal não teve acesso aos resultados, antes do término do estudo. Os pacientes foram avaliados ao início do estudo, em cada um dos quatro tempos de irradiação e aos 7, 14, 30, 60 e 90 dias após a última irradiação. Os pacientes foram categorizados, de acordo com seu percentual de sintoma, ao final do último controle: sem ardência (S.A)- 0% de sintomatologia, ótimo (O)- 1% a 25%, bom (B)- 26%-50%, regular (R)- 51%-75%, inalterado (I)- 76-100% e piora (P)- valores superiores a 100%. A análise estatística apontou uma melhor resposta no grupo Laser (p=0,03; Teste Exato de Fisher). Concluiu-se que a terapia com laser em baixa intensidade, segundo o protocolo utilizado neste estudo, produz benefício aos pacientes portadores da síndrome de ardência bucal, sem apresentar qualquer efeito colateral indesejável, sugerindo o aprofundamento da pesquisa nesse campo. / Burning Mouth Syndrome (BMS) is a condition of unknown etiology, characterized by a burning sensation in the oral mucosa in the absence of any clinical sign, which treatment is still unsatisfactory. The aim of this study was to evaluate the effectiveness of low intensity laser therapy for SAB patients, through a randomized controlled clinical trial. Twenty-three patients affected by SAB met the inclusion criteria, complied with the established protocol and had their data analyzed. Patients initial evaluation comprised a complete clinical examination, unstimulated salivary flow, hematological examination and psychological assessment focused on identifying the quality of life and signs of depression. Two experimental patients groups were constituted: a Laser group and a Placebo group, which received four irradiations, two per week, of low intensity laser or false irradiation, respectively. The laser device utilized was a low intensity laser (Quantum, EccoFibras, Campinas, Brazil) GaAlAs, emitting 790 nm with120 mW of power. The irradiations were performed scanning the areas of mucosa affected by the burning sensation, delivering a dose of 6 J/cm2. Patients were allocated among the groups with the aid of a randomization computer program. Patients were kept blind to the type of radiation received (laser or placebo). The results were obtained by a researcher assistant, who was unaware of the type of irradiation effected, by means of a visual analogue scale (VAS) and a global perception scale (EPG). The principal investigator had access to the results only at the end of the study. Patients were evaluated at baseline in each of the four times of irradiation and at 7, 14, 30, 60 and 90 days after the last irradiation. Patients were categorized according to their percentage of symptom at the end of last control: no burning (SA) - 0% of symptoms, optimal (O) - 1% to 25%, good (B) - 26% -50 %, regular (R) - 51% -75%, unchanged (I) - 76-100%, and worsening (P) - values exceeding 100%. Statistical analysis showed a better response in the laser group (p = 0.03, Fisher\'s exact test). It was concluded that low intensity laser therapy, according to the protocol applied in this study, produces benefit to patients with burning mouth syndrome, without any undesirable side effect, suggesting further research in this field.
9

Laser de baixa intensidade na modulação do processo Inflamatório na prevenção da Síndrome do insucesso da cirurgia espinhal

Holanda, Vanessa Milanesi 18 December 2013 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2015-07-27T13:57:51Z No. of bitstreams: 1 Vanessa Milanesi Holanda.pdf: 1185275 bytes, checksum: 780810a027a0b0fd0a45e08edaa3f88d (MD5) / Made available in DSpace on 2015-07-27T13:57:51Z (GMT). No. of bitstreams: 1 Vanessa Milanesi Holanda.pdf: 1185275 bytes, checksum: 780810a027a0b0fd0a45e08edaa3f88d (MD5) Previous issue date: 2013-12-18 / Every year, over one million individuals worldwide were submitted to laminectomies, with a rate failure higher than 40%. Post laminectomy epidural adhesion is implicated as a main cause of ‘‘failed back surgery syndrome’’ and associated with high risk of complications during the revision surgery. The postoperative epidural scar can cause extradural compression or dural tethering, which lead to recurrent radicular pain and physical impairment. Several studies in the literature are signalizing that Low-Level-Laser-Therapy (LLLT) is proven to be an effective tool to assist the inflammatory process and wound healing, as well to prevent infection and dehiscence. The objectives of this project are to delineate and evaluate the LLLT effects in spinal surgery. A prospective randomized, controlled trial with a total of 48 patients, who underwent to laminectomy, were divided into 2 groups, as following: in 25 randomized patients, LLLT infrared, Power = 40mW, Fluence= 7.44 J/cm2 was applied during transoperatory phase, on the laminectomy site, on the subcutaneous tissue and surrounding the wound site. In the second group, 23 patients were induced to believe that they were getting the same treatment, avoiding psychological effect, although LLLT was not operating. In those groups, C reactive protein (CRP), lactic dehydrogenase and creatine kinase (CK) were assessed in the second and fifth days after surgery, digital temperature and visual analogue scale were measured, pre and post LLLT application. The drainage output were collected in the first and second days, following surgery in both groups. Interleukins 1, 4, 6, 8 and 10 and tumor necrosis factor alpha (TNF- α) were evaluated. The results indicated temperature decrease, pain relief and accelerated wound healing in laser group. LLLT facilitates the wound cicatrization, due to a prompt resolution while acute inflammation, as suggested by the CRP chiefly drop from second to fifth postoperative day; in which the proliferation phase of healing demonstrated statistically significant values by fast fall in the laser group of CK, suggesting that these markers may guide LLLT treatment evolution. In conclusion, it was demonstrated that only three LLLT applications could assist better wound healing, reduce the lesion inflammation, decrease drainage output and promote analgesia in the PO post laminectomy with cost-effectiveness. / A cada ano, mais de um milhão de pessoas ao redor do mundo são submetidas à cirurgia da coluna vertebral, com uma taxa de insucesso superior a 40%. A fibrose epidural pós-laminectomia é apontada como a principal causa da síndrome do insucesso da cirurgia espinhal e está associada ao aumento do risco de complicações durante a cirurgia de revisão. A cicatriz pós-operatória peridural pode causar compressão extradural, resultando em dor radicular recorrente e déficits neurológico. Inúmeros estudos sinalizam que o laser de baixa intensidade (LBI) tem sido descrito como eficaz no auxílio do decréscimo da inflamação e cicatrização de feridas cirúrgicas. Objetivos: Delinear e analisar os efeitos da laserterapia em cirurgia da coluna vertebral. Metodologia: Estudo prospectivo randomizado e controlado por placebo com 48 pacientes submetidos à laminectomia, divididos aleatoriamente em 2 grupos. No primeiro grupo, 25 pacientes receberam Laser no infravermelho (λ= 804nm), Potência= 40mW, Fluência= 7.44 J/cm2 durante a cirurgia nas seguintes áreas: durante o transoperatório na dura-máter, sobre subcutâneo e sobre a pele; além do leito da ferida cirúrgica em 24h e 72h após a cirurgia. No segundo grupo, 23 pacientes foram induzidos a acreditar que receberam o mesmo tratamento. Antes da cirurgia, além dos dias 2 e 5 pós operatórios (PO), foram coletadas amostras de sangue do paciente para estudo de PCR, DHL e CK. Antes e após a laserterapia, a temperatura corpórea foi medida por meio de termômetro digital e a dor foi avaliada por meio de escala analógica visual. Nos dias 1º e 2º PO, o débito do dreno foi coletado e analisado as citocinas foram avaliadas por ELISA interleucinas 1, 4, 6, 8, 10 e TNF-alfa do exsudato. Resultados: Demonstraram uma diminuição de temperatura, alívio da dor e cicatrização acelerada no grupo laser, além de uma redução do débito do dreno, contribuindo para redução da perda sanguínea e evitando infecção. O LBI facilita a reparação de feridas, devido a uma resolução mais rápida do processo inflamatório agudo, como foi sugerido pela maior queda do PCR do 2º para o 5º dia pós-operatório. A fase de proliferação da cicatrização foi antecipada, já que os valores de CK revelaram uma queda mais rápida no grupo do laser, sugerindo que esses marcadores inflamatórios podem nortear o tratamento com LBI. Conclusão: Demonstramos que três aplicações do LBI podem reduzir a inflamação, auxiliar na drenagem e estimular uma melhor cicatrização de feridas, ajudando no processo de analgesia no pós-operatório na cirurgia de coluna vertebral.
10

Fotobiomodulação comparativa entre o laser e LED de baixa intensidade na angiogênese de feridas cutâneas de ratos / Comparative fotobiomodulation between the LED and low intensity laser in the angiogenisis of skin wounds in rats

Corazza, Adalberto Vieira 12 December 2005 (has links)
Os diodos emissores de luz – Light Emitting Diodes – (LEDs) são uma fonte de luz que estão sendo introduzidas comercialmente, mas com discreta base científica nesta modalidade fototerapêutica. O presente estudo comparou os efeitos angiogênicos da luz laser coerente e colimada à luz LED ausente de coerência e colimação em feridas induzidas em ratos, com fluências diferentes. O modelo experimental consistia da indução de uma ferida circular no quadríceps de 120 ratos, utilizando um “punch" com 15 mm de diâmetro. Os animais foram divididos aleatoriamente em 5 grupos: laser (660 nm) e LED (635 nm), sendo cada um ajustado a 5 J/'CM POT.2' e 20 J/'CM POT.2', além do controle. Após 6 horas da indução das feridas, os grupos tratados recebiam aplicação pontual de contato, e irradiados a cada 24 horas. A angiogênese foi analisada por meio da histomorfometria (H.E), e a contração das feridas pelo software de planimetria, sendo estudados os resultados no 3º, 7º, 14º e 21º dias pós-lesão. Os achados da análise histológica no 3º dia foram determinantes para induzir uma grande eficiência na proliferação de vasos sanguíneos dos grupos tratados em relação ao controle, demonstrando uma taxa próxima da constante no 7º dia, e com discreto aumento no 14º dia, porém com destaque para a tecnologia LED a 5 J/'CM POT.2' (p '< OU =' 0,05). No 21º dia, os grupos fototratados com fluência de 5 J/'CM POT.2' apresentavam valores estatísticos com maior eficiência na angiogênese quando comparados com o grupo laser a 20 J/'CM POT.2, sugerindo que fluências elevadas podem induzir um processo do tipo saturação. Não ocorreu diferença da neovascularização no centro e nas margens da ferida (p '< OU =' 0,05), sugerindo que ocorria uma fotobiomodulação de toda a lesão, favorecendo o crescimento homogêneo dos vasos sanguíneos. Tanto o laser quanto o LED não apresentaram resultados significativos na redução da área das feridas. As fototerapias a laser e LED de baixa intensidade sugeriram que a coerência e a colimação não eram fatores decisivos para induzir alterações nas funções celulares, e sim a banda de absorção do espectro eletromagnético. Ambas as fontes de luz vermelha ajustadas a fluências de 5 J/'CM POT.2' podem demonstrar resultados expressivos no estímulo angiogênico em pele lesada / The light emitting diodes (LEDs) are a source of light that have been commercially introduced, but still with a lack in its scientific basis in this phototherapeutic modality. The present study compared the angiogenics effects of the laser and LED illumination in induced wounds in rat, with fluencies different. The experimental model consisted of the induction of a circular wound on the quadriceps of 120 rats, using a “punch" with 15 mm diameter. Animals were divided randomyzed in 5 groups: laser and LED each device with a dosage of 5 J/'CM POT.2' and 20 J/'CM POT.2', and control. After 6 hours of the induction of the wounds, the treated groups received contact of punctual application, and irradiated every 24 hours. The angiogenesis was studied through the histomorphometric (H.E) and the wounds contraction was photographed and analyzed in the planimetrical software in the 3rd, 7th, 14th and 21st lesion induced days. The discoveries of the histological analysis in the 3rd day revealed larger efficiency in the proliferation of the blood vessels in all irradiated groups in comparison to controls, being a rate near of the constant in the 7th day, following to discreet improves in the 14th, even so with prominence for the LED with 5 J/'CM POT.2'. In the 21st day, the groups phototreatment with fluence of 5 J/'CM POT.2' showed similar statistically values in the larger efficiency in the angiogenesis, when to compare to laser with 20 J/'CM POT.2', suggesting high fluencies can induced a saturation process. The average of the area reduction of the wound didn't present similar statistician values of the treated groups in relation to the control (p '< OU =' 0,05). The phototherapeutic laser and LEDs of low intensity they suggested that the coherence and the collimation were not decisive factors to induce alterations in the cellular functions, but the band of the spectrum electromagnetic. The both red source of light agreements to fluencies of the 5 J/'CM POT.2', they can demonstrate expressive results in the incentive ulcerated skin angiogenic

Page generated in 0.4408 seconds