• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 5
  • 3
  • 3
  • Tagged with
  • 35
  • 14
  • 13
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo do potencial de contaminação de lixiviados gerados em aterros de resíduos da construção civil por meio de simulações em colunas de lixiviação / Study of the pollution potential of leachate of construction and demolition wastes landfills in lysimeters

Córdoba, Rodrigo Eduardo 27 June 2014 (has links)
No Brasil, a Resolução CONAMA nº 307/2002 e a Resolução CONAMA nº 448/2012 definem que os resíduos da construção civil (RCC) classe A, caso não sejam reutilizados ou reciclados na forma de agregados, devem ser destinados para aterros de resíduos classe A de reservação de material para usos futuros. Porém, pequenas quantidades de resíduos de outras classes, e resíduos não inertes acabam dispostos neste tipo de aterro. Esse fato pode ser agravado devido esses aterros não possuírem impermeabilização de base e sistemas de drenagem de lixiviados, o que pode favorecer a migração desses lixiviados de RCC para reservas de água, e colocar em risco a saúde da população e o meio ambiente. Com intuito de contribuir nessa área de conhecimento o presente estudo teve por finalidade investigar o potencial de contaminação de lixiviados de aterros de resíduos da construção civil por meio de simulações em colunas de lixiviação. Para tanto, foi realizado um estudo por meio de duas etapas &#8211 simulação de lixiviação de amostras de RCC em colunas de lixiviação (saturadas e não saturadas), e coleta de água subterrânea do aterro de RCC classe A. Resultados da pesquisa apontaram que as amostras de agregados de RCC classe A foram classificadas, de acordo com a NBR 10.004 (ABNT, 2004), como sendo resíduos não perigosos e não inertes &#8211 Classe II A. A hipótese tema do estudo foi verificada, a qual apontou que existe potencial de contaminação dos lixiviados gerados em aterros de RCC Classe A, os quais podem vir a poluir ou contaminar o solo e as águas subterrâneas inviabilizando o uso dessas águas para consumo humano. As concentrações máximas dos lixiviados de RCC que excederam o valor máximo permitido para consumo humano nas simulações foram: sulfato (950 mg/L), dureza (11.280 mg/L), cor (124 uH), Pb (0,36 mg/L), Cd (0,075 mg/L), Ni (0,088 mg/L), Fe (0,658 mg/L), Ba (1,205 mg/L), Cr (0,125 mg/L), Mn (0,297 mg/L), e Al (3,44 mg/L). A pesquisa também contribuiu para melhoria de projetos, execução e controle de aterros de resíduos da construção civil, a fim de futuramente equacionar possíveis impactos negativos gerados por esse tipo de resíduo ao solo e recursos hídricos. / In Brazil, the resolutions nº 307/2002 and nº 448/2012 of the National Environmental Council (CONAMA) define that the construction and demolition (C&D) class A - reusable or recyclable wastes as aggregates, such as ceramic components, grout and concrete -, if not reused or recycled as aggregates, should be going to C&D wastes landfill. These wastes must be disposed in the soil for the reservation of segregated materials for future use or future use of the area. However, these landfills receive small quantities of wastes from other sources and non-inert wastes. This fact can be aggravated because the C&D wastes are disposed in these unlined landfills and without drains of leachate. In this context, the C&D wastes leachate may migrate to water supplies causing risks to both human health and the environment. In an attempt to contribute to this area of knowledge, this project aims to investigate the pollution potential of leachate of construction and demolition wastes landfills in lysimeters. A survey will be conducted in two stages &#8211 simulation of leachate samples of C&D wastes lysimeters (saturated and unsaturated), and study of the C&D wastes landfill of the city through the collection of groundwater. Results of the research classified, for metals, the samples of aggregates of C&D wastes class A &#8211 such as ceramic components (bricks, blocks), grout and concrete &#8211 as non-hazardous and non-inert. The pollution of leachate of C&D wastes landfills was observed. The presence of these contaminants could affect the use of this water for human consumption. The parameters that exceeded the maximum value for human consumption were: sulfate (950 mg/L), hardness (11,280 mg/L), color (124 uH), Pb (0.36 mg/L), Cd (0.075 mg/L), Ni (0.088 mg/L), Fe (0.658 mg/L), Ba (1,205 mg/L) Cr (0.125 mg/L) Mn (0,297 mg/L), and Al (3.44 mg/L ).The research identified requirements for improvement projects, execution and control of C&D wastes landfills to minimize future potential adverse impacts generated by these residues in water resources.
22

Aplicação do reator de chicanas no tratamento de lixiviados de aterros sanitários de resíduos sólidos urbanos para remoção de nitrogênio amoniacal por “stripping”

Caetano, Marcelo Oliveira 03 1900 (has links)
Submitted by Fabricia Fialho Reginato (fabriciar) on 2015-08-03T22:53:16Z No. of bitstreams: 1 MarceloCaetano.pdf: 5404511 bytes, checksum: f5ccf4e834b73eeb355f4e39a14ef0cf (MD5) / Made available in DSpace on 2015-08-03T22:53:16Z (GMT). No. of bitstreams: 1 MarceloCaetano.pdf: 5404511 bytes, checksum: f5ccf4e834b73eeb355f4e39a14ef0cf (MD5) Previous issue date: 2009-03 / Caixa Econômica Federal / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / MMA - Ministério do meio Ambiente / PROSAB - Programa de Pesquisa em Saneamento Básico / UNISINOS - Universidade do Vale do Rio dos Sinos / Em lixiviados de Aterros Sanitários (LAS), o nitrogênio amoniacal (NA) pode alcançar concentrações superiores a 2000 mg/L e, se disposto no meio ambiente sob estas concentrações, pode causar severos impactos ambientais e à saúde pública. Entre as alternativas para remoção de NA de lixiviados, o processo de “stripping” é um dos métodos utilizados mundialmente e que se destaca tecnicamente. O objetivo deste trabalho foi o estudo da remoção de amônia por “stripping” do lixiviado proveniente do Aterro Sanitário de São Leopoldo/RS, utilizando um processo físico de tratamento. O estudo foi desenvolvido através de ensaios de batelada em Reator de Chicanas (RC) precedidos por ensaios de bancada que empregaram Teste de Jarros. As variáveis testadas para o monitoramento do experimento foram: concentração inicial de NA e vazão de recirculação de lixiviado; sendo realizadas amostragens e análises físicoquímicas dos seguintes parâmetros: pH, DQO, temperatura, série de nitrogênio, série de sólidos, alcalinidade, nitrito e nitrato para verificação da eficiência do sistema. Em nenhum dos ensaios foi promovido a alteração do pH e/ou temperatura do lixiviado. Os resultados mostraram, para um tempo de detenção hidráulica (TDH) de 12 dias, uma remoção de NA variando de 27% a 52%, porém não sendo suficiente para o atendimento dos padrões nacionais legislativos de emissão de efluentes em recursos hídricos. O parâmetro “temperatura”, estatisticamente, mostrou influenciar na remoção de NA, sendo obtidos maiores remoções para temperaturas ambiente superiores a 20ºC. Para as condições avaliadas por esta dissertação, conclui-se que, em temperaturas ambiente superiores a 20ºC a melhor opção técnica-ambiental de tratamento de LAS é a utilização, no RC, de vazão de recirculação de lixiviado de 1,7 m³/h. Já para temperaturas inferiores a 20ºC, o melhor desempenho do RC ocorreu com vazão de recirculação 0,0m³/h (sem bomba); o que representa uma redução do consumo de energia, entretanto sugere-se um aumento do TDH. Pelos resultados conseguidos, o RC se torna uma opção viável tecnicamente para tratamento de LAS, como um processo físico para remoção de amônia por “stripping”, podendo ser indicado como um pré- tratamento aos sistemas biológicos. / The ammoniacal nitrogen (AN) from landfill leachates (LL) may cause severe impacts on the environment and public health if disposal at concentrations above 2000 mg/L. The stripping process is one of the methods worldwide used and technically outstanding among the alternatives for AN removal from leachates. The study of physical treatment process for removal of ammonia from the leachate in a landfill in São Leopoldo/RS was the objective of this work. The study was developed through batch tests in a baffle reactor (BR) that was previous by bench tests using the jar test. The variables tested to monitor the experiment were: initial concentration of AN and leachate recirculation flow. Samplings and physicochemical analyses of the following parameters were performed: pH, COD, temperature, nitrogen series, solids series, alkalinity, nitrite and nitrate to verify system efficiency. None of the assays was realized changes in pH and/or temperature in leachate. The hydraulic detention time (HDT) of 12 days resulted in AN removal ranging from 27% to 52%. However, this is not sufficient to comply with the national legislative standards of effluent emission into water resources. Statistically the “temperature” parameter showed influence on AN removal and greater removals were obtained for ambient temperatures above 20ºC. For the evaluated conditions was conclude that the best technical-enviromental option for treatment of LL is the leachate recirculation flow of 1.7 m³/h at temperatures higher than 20ºC. On the other hand, for temperatures below 20ºC the best BR performance occurred with leachate recirculation flow of 0.0 m³/h (without pump). This represents a reduction of energy consumes but is necessary an increase of HDT. According to the results obtained, the BR is a technically feasible option to treat LL as a physical process to remove ammonia by stripping and it may be indicated as a pre-treatment before biological systems.
23

Avaliação das interferências da disposição de resíduos de fossas e tanques sépticos em lagoas de estabilização que tratam lixiviados: estudo de caso para o aterro sanitário de Anápolis (GO) / Evaluation of septage disposal in stabilization ponds that treat landfill leachate: case of study to the Anapolis' landfill

Carrilho, Samara Monayna Alves Vasconcelos 20 March 2014 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-11-03T16:48:26Z No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-11-03T16:49:41Z (GMT) No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-03T16:49:41Z (GMT). No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-03-20 / The destination of septage has resulted in environmental and public health problems, due especially to the lack of adequate alternatives for its destination and of closer, more rigorous monitoring. The problem worsens in areas lacking sewage treatment plants, since the disposal in such systems has been the most widely used practice in the country. In this way, the current research aims to evaluate the effects of the sludge disposal in the performance, operation and maintenance of treatment plant of leachate from landfill of Anápolis (GO). The characterization of the municipality RST was also performed by analyzing of twelve composite samples, each one from five vacuum trucks. It was evaluated the system consists of two identical modules, one it was the control group and another one received the RST. This module was submitted, increasingly, to differents Rate Volumetric Application (RVA) of RTS. Thus, the study was divided into five phases, starting with RVA of 13 % up to 204 %. Various parameters (BOD, COD, pH, oil and grease, total phosphorus, ammoniacal nitrogen, suspended solids, settling solids and Escherichia coli) were analyzed for the samples from the influent and effluent of the anaerobic and facultative ponds. It was also evaluated the impact on the maintenance and operation in the system plant, by measuring the height of the sludge in anaerobic lagoon and quantification of scum formed on the surface anaerobic pond. In facultative ponds it was performed by raising the phytoplankton community, ordering to identify possible interference in the richness and abundance of algae and cyanobacteria in these ponds. The data were statistically analyzed by the Studentt test, and the results indicated that until to 18 % of RVA there were no significant changes in the quality of treated leachate (effluent of stabilization ponds). Since the RVA of 35 % was detected a significant difference in the concentration of E. coli and ammoniacal nitrogen in treated effluent (p < 0.05). At the RVA of 204% the concentration of phosphorus in the final effluent from facultative pond increased. There was an increase in sludge generation of 266% in the receiving anaerobic pond and only 38% in the control anaerobic pond. In addition, there was a thick layer of scum only on the surface of the receiving anaerobic pond. The phytoplankton community of facultative ponds was similar and presented low diversity. The Chlorella genera were dominant in both lagoons. From the results of this study, it is recommended the conjugate treatment of RFTS and leachate in stabilization ponds systems, because even applying RVA of 204%,the final effluent don’t have concentrations higher than those stipulated by CONAMA Resolution 430/2011. / A destinação dos Resíduos de Fossa e Tanque Séptico (RFTS) tem resultado em problemas ambientais e de saúde pública, devido principalmente à falta de alternativas adequadas para a destinação, e de fiscalização mais rigorosa. O problema se agrava em municípios desprovidos de estações de tratamento de esgoto, já que a disposição nesses sistemas tem sido a prática mais utilizada no país. Neste contexto, a presente pesquisa teve por finalidade avaliar as possíveis interferências da disposição dos RFTS no desempenho, operação e manutenção no sistema de tratamento de lixiviados do Aterro Sanitário de Anápolis (GO). Também foi realizada a caracterização dos RFTS do município, através da análise de doze amostras compostas, cada uma proveniente de cinco caminhões limpa-fossas. Avaliou-se o sistema composto por dois módulos idênticos, sendo um testemunho e outro receptor de RFTS. Este foi submetido, de forma crescente, a diferentes Taxas de Aplicação Volumétrica (TAV) de RFTS, iniciando com TAV de 13%, até chegar a TAV de 204%. O estudo foi executado e os parâmetros físico-químicos e microbiológicos (DBO, DQO, pH, OG, fósforo total, nitrogênio amoniacal, sólidos suspensos, sólidos sedimentáveis e Escherichia coli) de amostras simples do afluente e efluente das lagoas anaeróbias e facultativas de ambos módulos foram analisados. Nas lagoas anaeróbias verificaram-se os possíveis impactos na manutenção e operação do sistema, através da medição da altura do lodo sedimentado no fundo da lagoa e da quantificação da escuma formada em sua superfície. Nas lagoas facultativas realizou-se o levantamento da comunidade fitoplanctônica, visando identificar possíveis interferências da codisposição de RFTS na riqueza e abundância de algas e cianobactérias. Os dados obtidos foram tratados estatisticamente, através do teste t the Student, e os resultados indicaram que até a TAV de 18% não houve alterações significativas na qualidade do lixiviado tratado (efluente das lagoas de estabilização). A partir da TAV de 35% detectou-se diferença significativa na concentração de E. coli e nitrogênio amoniacal no efluente tratado (p<0,05) e para a TAV de 204% ocorreu aumento na concentração de fósforo no efluente final da lagoa facultativa receptora. Houve interferência na manutenção e operação das lagoas, com aumento de 266% na altura do lodo sedimentado da lagoa anaeróbia receptora, ao passo que na lagoa anaeróbia testemunha, o aumento foi de 38%. Densa camada de escuma formou-se apenas na superfície da lagoa anaeróbia receptora. A comunidade fitoplanctônica das lagoas facultativas apresentou baixa diversidade, com predominância de algas do gênero Chlorella. Os resultados indicaram alta variabilidade dos RFTS do município de Anápolis. A partir deste estudo, recomenda-se o tratamento conjugado de RFTS e lixiviados em sistemas de lagoas de estabilização, pois mesmo aplicando alta TAV (204%), o efluente final não contrariou o padrão de lançamento proposto pela Resolução CONAMA 430/2011.
24

Estudo da tratabilidade anaeróbia de lixiviados de aterros sanitários utilizando filtros biológicos operados em batelada sequencial / Study of anaerobic treatability of leachates from landfills using biological sequencing batch filters

Tatiana Corrêa 31 August 2012 (has links)
Este trabalho procurou contribuir na busca por informações das características de tratabilidade de lixiviados de diferentes aterros sanitários do interior de São Paulo, e estabelecer correlações entre parâmetros analisados. As coletas foram realizadas nos aterros sanitários de: São Carlos, Araraquara, Rio Claro, Ribeirão Preto, Catanduva e Votorantim. O experimento foi conduzido a 30ºC, em dois filtros biológicos anaeróbios operados em batelada sequencial, com capacidade de tratamento de 8 L de lixiviado cada e biomassa imobilizada em suportes de poliuretano inoculados com lodo do fundo de uma das lagoas de lixiviados do aterro de São Carlos-SP. Os filtros operados simultaneamente eram idênticos e foram, alimentados com os lixiviados. O monitoramento do reator foi realizado por meio da caracterização físico-química do afluente e efluente de cada ciclo de batelada e dois perfis temporais. Foi realizada a caracterização do lodo, que apresentou morfologias microbianas pertinentes ao tratamento anaeróbio. A caracterização do lixiviado de São Carlos apresentou sólidos totais de 14,5 g/L e sólidos totais voláteis de 5,1 g/L, nitrogênio amoniacal de 2.411 mg/L e nitrato de 115,5 mg/L. Além disso, apresentou resultados mais elevados para DQO (bruta 3.940 mg/L e filtrada 3.565 mg/L); entretanto apresentou características recalcitrantes ao tratamento anaeróbio, assim como os lixiviados de Araraquara, Rio Claro e Ribeirão Preto. Nos tratamentos dos lixiviados de Catanduva e Votorantim a eficiência de remoção de DQO foi de aproximadamente 30%. Com exceção do lixiviado de Catanduva, o nitrogênio amoniacal esteve presente em todos os lixiviados em altas concentrações, representando cerca de 80% do nitrogênio total e refletindo na alcalinidade total. A concentração de metais estava dentro dos valores máximos permitidos pela Resolução no. 430/2011 do CONAMA. A população de coliformes totais manteve-se estável (de 2,3 x \'10 POT.5\' para 1,1 x \'10 POT.5\' NMP/100 mL) no lixiviado de São Carlos, no entanto, em todos os demais tratamentos, os coliformes totais e termotolerantes foram removidos totalmente, demonstrando a eficiência do tratamento em filtro anaeróbio para estes parâmetros. Os lixiviados de aterros jovens apresentaram algumas características de aterros velhos, o que sugere que eles passaram rapidamente para a fase metanogênica. A implementação de filtros biológicos nos aterros sanitários torna-se uma alternativa de pré-tratamento em municípios com número reduzido de habitantes e baixa vazão de lixiviado, sendo possível dimensionar o filtro biológico e viabilizar o tratamento. / The present study intends to contribute in the research for information about anaerobic treatability of leachates from different landfills in the country part of São Paulo State, and also to establish correlation among analyzed parameters. Leachates were collected in landfills from different cities: São Carlos, Araraquara, Rio Claro, Ribeirão Preto, Catanduva and Votorantim. Experiments were carried out in 30ºC, in two anaerobic biological sequencing batch filters, with capacity for treating 8 L of leachate and immobilized biomass in polyurethane supports inoculated with sludge from one of the São Carlos landfill leachate reservoir. Filters are identical and were operated simultaneously a filled with leachates from the places mentioned above. Reactors monitoring was performed by through physicochemical characterization of the influent and effluent of each batch cycle, and two temporal profiles. Characterization of the sludge was performed and showed microbial morphologies pertinent to anaerobic treatment. Characterization of the leachates from São Carlos showed total solids of 14,5 g/L and total volatile solids of 5,1 g/L, ammonia nitrogen of 2.411 mg/L and nitrate of 115,5 mg/L. Furthermore depicted high results of COD (gross 3.940 mg/L and filtered 3.565 mg/L); however presented recalcitrante behavior to anaerobic treatment such as the leachates of Araraquara, Rio Claro and Ribeirão Preto. The treatment of leachates from Catanduva and Votorantim presented removal efficiency of COD of approximately 30%. Except for leachate of Catanduva, the ammonia nitrogen was present in high concentrations from all the leachates representing about of 80% of the total nitrogen. These high concentrations of ammonia nitrogen reflected in the total alkalinity. The metals concentration was within the maximum values allowed by Resolution number 430/2011 of CONAMA. In the leachates of São Carlos, the population of total coliforms remained stable (of 2,3 x \'10 POT.5\' to 1,1 x \'10 POT.5\' NMP/100 mL), however, in all other treatments, the total coliforms and thermotolerant coliforms were fully removed, demonstrating the efficiency of treatment in anaerobic filter for such parameters. The leachates of young landfills presented some characteristics of old landfills, suggesting that it passed quickly to metanogenic phase. The implementation of biological filters in landfills would be an alternative as a pretreatment in \"young\" landfills, with few inhabitants and low leachate flow, making it possible to measure the biological filter and facilitating treatment.
25

Estudo do potencial de contaminação de lixiviados gerados em aterros de resíduos da construção civil por meio de simulações em colunas de lixiviação / Study of the pollution potential of leachate of construction and demolition wastes landfills in lysimeters

Rodrigo Eduardo Córdoba 27 June 2014 (has links)
No Brasil, a Resolução CONAMA nº 307/2002 e a Resolução CONAMA nº 448/2012 definem que os resíduos da construção civil (RCC) classe A, caso não sejam reutilizados ou reciclados na forma de agregados, devem ser destinados para aterros de resíduos classe A de reservação de material para usos futuros. Porém, pequenas quantidades de resíduos de outras classes, e resíduos não inertes acabam dispostos neste tipo de aterro. Esse fato pode ser agravado devido esses aterros não possuírem impermeabilização de base e sistemas de drenagem de lixiviados, o que pode favorecer a migração desses lixiviados de RCC para reservas de água, e colocar em risco a saúde da população e o meio ambiente. Com intuito de contribuir nessa área de conhecimento o presente estudo teve por finalidade investigar o potencial de contaminação de lixiviados de aterros de resíduos da construção civil por meio de simulações em colunas de lixiviação. Para tanto, foi realizado um estudo por meio de duas etapas &#8211 simulação de lixiviação de amostras de RCC em colunas de lixiviação (saturadas e não saturadas), e coleta de água subterrânea do aterro de RCC classe A. Resultados da pesquisa apontaram que as amostras de agregados de RCC classe A foram classificadas, de acordo com a NBR 10.004 (ABNT, 2004), como sendo resíduos não perigosos e não inertes &#8211 Classe II A. A hipótese tema do estudo foi verificada, a qual apontou que existe potencial de contaminação dos lixiviados gerados em aterros de RCC Classe A, os quais podem vir a poluir ou contaminar o solo e as águas subterrâneas inviabilizando o uso dessas águas para consumo humano. As concentrações máximas dos lixiviados de RCC que excederam o valor máximo permitido para consumo humano nas simulações foram: sulfato (950 mg/L), dureza (11.280 mg/L), cor (124 uH), Pb (0,36 mg/L), Cd (0,075 mg/L), Ni (0,088 mg/L), Fe (0,658 mg/L), Ba (1,205 mg/L), Cr (0,125 mg/L), Mn (0,297 mg/L), e Al (3,44 mg/L). A pesquisa também contribuiu para melhoria de projetos, execução e controle de aterros de resíduos da construção civil, a fim de futuramente equacionar possíveis impactos negativos gerados por esse tipo de resíduo ao solo e recursos hídricos. / In Brazil, the resolutions nº 307/2002 and nº 448/2012 of the National Environmental Council (CONAMA) define that the construction and demolition (C&D) class A - reusable or recyclable wastes as aggregates, such as ceramic components, grout and concrete -, if not reused or recycled as aggregates, should be going to C&D wastes landfill. These wastes must be disposed in the soil for the reservation of segregated materials for future use or future use of the area. However, these landfills receive small quantities of wastes from other sources and non-inert wastes. This fact can be aggravated because the C&D wastes are disposed in these unlined landfills and without drains of leachate. In this context, the C&D wastes leachate may migrate to water supplies causing risks to both human health and the environment. In an attempt to contribute to this area of knowledge, this project aims to investigate the pollution potential of leachate of construction and demolition wastes landfills in lysimeters. A survey will be conducted in two stages &#8211 simulation of leachate samples of C&D wastes lysimeters (saturated and unsaturated), and study of the C&D wastes landfill of the city through the collection of groundwater. Results of the research classified, for metals, the samples of aggregates of C&D wastes class A &#8211 such as ceramic components (bricks, blocks), grout and concrete &#8211 as non-hazardous and non-inert. The pollution of leachate of C&D wastes landfills was observed. The presence of these contaminants could affect the use of this water for human consumption. The parameters that exceeded the maximum value for human consumption were: sulfate (950 mg/L), hardness (11,280 mg/L), color (124 uH), Pb (0.36 mg/L), Cd (0.075 mg/L), Ni (0.088 mg/L), Fe (0.658 mg/L), Ba (1,205 mg/L) Cr (0.125 mg/L) Mn (0,297 mg/L), and Al (3.44 mg/L ).The research identified requirements for improvement projects, execution and control of C&D wastes landfills to minimize future potential adverse impacts generated by these residues in water resources.
26

Lixiviados en plantas de residuos. Una contribución para la selección del proceso de tratamiento

Reyes Medina, Manuel 30 October 2015 (has links)
[EN] Leachate from waste landfill or treatment plants is a very complex and highly contaminated liquid effluent. In its composition, dissolved organic matter, inorganic salts, heavy metals and other xenobiotic organic compounds, are found, so it can be toxic, carcinogenic and capable of inducing a potential risk to biota and humans. European law does not allow such leachate to leave the premises without being depolluted. There are many procedures that enable debugging, always combining different techniques. Choosing the best method to use in each case is a complex decision, as it depends on many tangible and intangible factors that must be weighted to achieve a balance between technical, cost, and environmental sustainability. A hybrid method for choosing the optimal combination of techniques to apply in each case, by combining a multi-criteria hierarchical analysis based on expert data, obtained by the Delphi method, with an analysis by the method of VIKOR to reach a consensus solution is presented. This thesis will perform a sensitivity analysis on the weights of the criteria involved in the decision and performance values of the alternatives, expressed both in terms of the decision criteria. / [ES] El lixiviado de los vertederos de plantas de residuos es un líquido muy complejo y altamente contaminado. En su composición se puede encontrar materia orgánica disuelta, sales inorgánicas, metales pesados y otros compuestos orgánicos xenobióticos, por lo que pueden ser tóxicos, cancerígenos y capaces de inducir un riesgo potencial en el medio ambiente y los seres humanos. La legislación europea no permite que tales lixiviados salgan de las instalaciones sin ser depurados. Hay muchos procedimientos que permiten la depuración, siempre combinando diferentes técnicas. Elegir el mejor método a utilizar en cada caso es una decisión compleja, ya que depende de muchos factores tangibles e intangibles que deben sopesarse para lograr un equilibrio entre la técnica, el costo y la sostenibilidad ambiental. Se presenta un método híbrido para la elección de la combinación óptima de técnicas de depuración de entre las disponibles, mediante la aplicación de un análisis jerárquico de criterios múltiples AHP sobre la base de datos de expertos, obtenidos por el método Delphi, junto a un análisis de resultados por el método VIKOR, para llegar a una solución de consenso, que pueda ser asumible por la mayoría de los expertos consultados como propia. En esta tesis se realiza un análisis de sensibilidad en los pesos de los criterios de decisión y en los valores de rendimiento de las alternativas, expresados ambos en términos de los criterios de decisión. / [CA] El lixiviat dels abocadors de plantes de residus és un líquid molt complex i altament contaminat. En la seua composició es pot trobar matèria orgànica dissolta, sals inorgàniques, metalls pesats i altres compostos orgànics xenobiòtics, per la qual cosa poden ser tòxics, cancerígens i capaços d'induir un risc potencial en el medi ambient i els éssers humans. La legislació europea no permet que aquests lixiviats isquen de les instal·lacions sense ser depurats. Hi ha molts procediments que permeten la depuració, sempre combinant diferents tècniques. Triar el millor mètode a utilitzar en cada cas és una decisió complexa, ja que depèn de molts factors tangibles i intangibles que han de sospesar-se per aconseguir un equilibri entre la tècnica, el cost i la sostenibilitat ambiental. Es presenta un mètode híbrid per a l'elecció de la combinació òptima de tècniques de depuració d'entre les disponibles, mitjançant l'aplicació d'una anàlisi jeràrquica de criteris múltiples AHP sobre la base de dades d'experts, obtinguts pel mètode Delphi, al costat d'una anàlisi de resultats pel mètode VIKOR, per a arribar a una solució de consens, que puga ser assumible per la majoria dels experts consultats com a pròpia. En aquesta tesi es durà a terme una anàlisi de sensibilitat en els pesos dels criteris de decisió i en els valors de rendiment de les alternatives, expressats tots dos en termes dels criteris de decisió. / Reyes Medina, M. (2015). Lixiviados en plantas de residuos. Una contribución para la selección del proceso de tratamiento [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/56763
27

Mejoras en el tratamiento de lixiviados de vertedero de RSU mediante procesos de oxidación avanzada.

Primo Martínez, Oscar 21 November 2008 (has links)
Esta tesis doctoral está dirigida a la investigación y desarrollo de Procesos de Oxidación Avanzada (POAs), los cuales basan su capacidad en la generación in-situ de radicales hidroxilo (OH·), especie capaz de oxidar muchos compuestos orgánicos. Esta propiedad es aprovechada para conseguir la completa mineralización de los contaminantes o su degradación en sustancias más fácilmente biodegradables.Se plantean dos grandes objetivos:1) Contribuir al conocimiento científico a través del análisis y modelado del proceso UV/H2O2 aplicado a la degradación y mineralización de fenol. Para ello, se ha realizado una planificación experimental dirigida a estudiar la influencia de las variables de operación sobre parámetros globales del proceso, como el contenido total de materia orgánica o la toxicidad.2) Desarrollar una alternativa eficaz para la eliminación de materia orgánica de corrientes residuales de escasa biodegradabilidad mediante la aplicación de POAs. Se ha seleccionado el tratamiento de lixiviados de vertedero de residuos sólidos urbanos (RSU) como caso de estudio y se ha realizado un análisis comparativo de los procesos Fenton y foto-Fenton. Los experimentos se han realizado tanto a escala de laboratorio como a escala de planta piloto. / The aim of this thesis is the research and development of Advanced Oxidation Processes (AOPs). AOPs are based on the in-situ generation of hydroxyl radicals (OH·). These radicals are able to oxidize many organic compounds with high oxidation rates but in a non-selective way. This is useful to achieve the complete mineralization of the pollutants or its degradation into more easily biodegradable compounds.Two main objectives have been pursued in this thesis:1) To contribute to the scientific knowledge of the UV/H2O2 process through its analysis and modelling. Phenol degradation has been selected as a case of study. An experimental planning was established to study the influence of process variables on parameters such as total organic matter concentration and ecotoxicity.2) Research on new alternative treatments for suitable organic matter removal from recalcitrant waste effluents by AOPs. As study case, the leachate remediation from a municipal solid wastes landfill was selected. Fenton and photo-Fenton processes were compared and the operational conditions to achieve the maximum organic matter reduction and colour removal have been determined. Both laboratory scale and pilot plant experiments were carried out.
28

Partial nitritation of landfill leachate in a SBR prior to an anammox reactor : operation and modelling

Ganigué Pagès, Ramon 19 February 2010 (has links)
Els lixiviats d'abocadors urbans són aigües residuals altament contaminades, que es caracteritzen per les elevades concentracions d'amoni i el baix contingut de matèria orgànica biodegradable. El tractament dels lixiviats a través dels processos de nitrificació-desnitrificació convencionals és costós a causa de la seva elevada demanda d'oxigen i la necessitat d'addició d'una font de carboni externa. En els darrers anys, la viabilitat del tractament d'aquest tipus d'afluents per un procés combinat de nitritació parcial-anammox ha estat demostrada. Aquesta tesi es centra en el tractament de lixiviats d'abocador a través d'un procés de nitritació parcial en SBR, com un pas preparatori per a un reactor anammox. Els resultats de l'estudi han demostrat la viabilitat d'aquesta tecnologia per al tractament de lixiviats d'abocador. El treball va evolucionar des d'una escala inicial de laboratori, on el procés va ser testat inicialment, a uns exitosos experiments d'operació a llarg termini a escala pilot. Finalment, la tesi també inclou el desenvolupament, calibració i validació d'un model matemàtic del procés, que té com a objectiu augmentar el coneixement del procés. / Urban landfill leachate are highly contaminated wastewater, usually characterised by high ammonium concentrations and low biodegradable organic matter content. Treating leachate through conventional nitrification-denitrification processes is expensive due to its high oxygen demand and the requirement of a supplementary external carbon source. In recent years, the feasibility of treating such streams with a low C:N ratio by a combined partial nitritation-anammox process has been demonstrated. This thesis deals with the treatment of landfill leachate by a partial nitritation-SBR, as a preparative step for an anammox reactor. The results of the study have demonstrated the feasibility of this technology for the treatment of landfill leachate. The work evolved from initial lab-scale studies, where the process was first tested, to a successful long-term experiment at pilot-scale. In addition, the thesis also includes the development, calibration and validation of a mathematical model of the process, aiming at increasing process knowledge.
29

Remoção de amônia do lixiviado por arraste de ar e caracterização por fracionamento com membrana. / Removal of ammonia from the leachate by air drag and characterization by fractionation with membranes.

Rafael Gundim Silva 24 February 2011 (has links)
A proposta deste trabalho é estudar a tecnologia para a remoção de amônia do lixiviado através do processo físico-químico de arraste com ar e a sua caracterização por processos de fracionamento com membranas de MF e UF. Foram analisados no processo de arraste de ar os parâmetros pH, vazão de ar e tempo de operação. Foi verificada a remoção de nitrogênio amoniacal de 93,5% em um tempo de operação de 6 horas, com ajuste de pH igual a 11 e vazão de ar 100 L/h. Após a remoção do nitrogênio amoniacal, os lixiviados foram submetidos a processo de fracionamento com membranas de microfiltração (MF) e ultrafiltração (UF), sendo investigadas a remoção de amônia, a condutividade, DQO, COD, cloreto e pH. Obtiveram-se resultados praticamente constantes à medida que o lixiviado permeou nas membranas de MF e UF. Ademais, empregaram-se testes de toxicidade e ensaios de tratabilidade biológica com amostras de lixiviado bruto, lixiviado tratado (baixa concentração de amônia) e lixiviados fracionados com membranas de MF e UF. Nos ensaios de tratabilidade biológica os resultados mostraram que não houve uma remoção significativa de matéria orgânica e nos testes de toxicidade com organismos Danio rerio, embora tenha ocorrido uma redução na toxicidade na sequência dos experimentos, foi constatado que o lixiviado bruto, lixiviado tratado com remoção de amônia e fracionados com membranas de MF e UF mantiveram elevada toxicidade. / The proposal of present work is to study the technology for removing ammonia from leachate by physico-chemical process of air stripping and its characterization after fractionation processes with MF and UF membranes. Were analyzed the process of entrainment of air pH, air flow rate and operating time. Moreover, there was the removal of ammonia nitrogen from 93.5% in a running time of 6 hours, with pH adjustment equal to 11 and air flow rate 100 L / h. Soon after the first treatment the leachate were characterized in the process of fractionation with membranes (MF and UF) and were investigated the remotion of ammonia, conductivity, COD, COD, chloride and pH. Getting results were nearly constant as the leachate permeated the membranes of MF and UF. Moreover, were employed for toxicity tests and biological treatability tests on samples of raw leachate, leachate treatment group (low ammonia concentration) and leachates fractionated with the MF and UF membranes. In tests of biological treatability results showed no significant removal of organic matter and toxicity tests with organisms Danio rerio, besides the occurrence of a reduction in toxicity, it was found that the raw leachate, leachate treated with removal of ammonia and fractionated with the MF and UF membranes maintained high values of toxicity.
30

Remoção de amônia do lixiviado por arraste de ar e caracterização por fracionamento com membrana. / Removal of ammonia from the leachate by air drag and characterization by fractionation with membranes.

Rafael Gundim Silva 24 February 2011 (has links)
A proposta deste trabalho é estudar a tecnologia para a remoção de amônia do lixiviado através do processo físico-químico de arraste com ar e a sua caracterização por processos de fracionamento com membranas de MF e UF. Foram analisados no processo de arraste de ar os parâmetros pH, vazão de ar e tempo de operação. Foi verificada a remoção de nitrogênio amoniacal de 93,5% em um tempo de operação de 6 horas, com ajuste de pH igual a 11 e vazão de ar 100 L/h. Após a remoção do nitrogênio amoniacal, os lixiviados foram submetidos a processo de fracionamento com membranas de microfiltração (MF) e ultrafiltração (UF), sendo investigadas a remoção de amônia, a condutividade, DQO, COD, cloreto e pH. Obtiveram-se resultados praticamente constantes à medida que o lixiviado permeou nas membranas de MF e UF. Ademais, empregaram-se testes de toxicidade e ensaios de tratabilidade biológica com amostras de lixiviado bruto, lixiviado tratado (baixa concentração de amônia) e lixiviados fracionados com membranas de MF e UF. Nos ensaios de tratabilidade biológica os resultados mostraram que não houve uma remoção significativa de matéria orgânica e nos testes de toxicidade com organismos Danio rerio, embora tenha ocorrido uma redução na toxicidade na sequência dos experimentos, foi constatado que o lixiviado bruto, lixiviado tratado com remoção de amônia e fracionados com membranas de MF e UF mantiveram elevada toxicidade. / The proposal of present work is to study the technology for removing ammonia from leachate by physico-chemical process of air stripping and its characterization after fractionation processes with MF and UF membranes. Were analyzed the process of entrainment of air pH, air flow rate and operating time. Moreover, there was the removal of ammonia nitrogen from 93.5% in a running time of 6 hours, with pH adjustment equal to 11 and air flow rate 100 L / h. Soon after the first treatment the leachate were characterized in the process of fractionation with membranes (MF and UF) and were investigated the remotion of ammonia, conductivity, COD, COD, chloride and pH. Getting results were nearly constant as the leachate permeated the membranes of MF and UF. Moreover, were employed for toxicity tests and biological treatability tests on samples of raw leachate, leachate treatment group (low ammonia concentration) and leachates fractionated with the MF and UF membranes. In tests of biological treatability results showed no significant removal of organic matter and toxicity tests with organisms Danio rerio, besides the occurrence of a reduction in toxicity, it was found that the raw leachate, leachate treated with removal of ammonia and fractionated with the MF and UF membranes maintained high values of toxicity.

Page generated in 0.0598 seconds