Study of a generation capacity expansion on an island

Guilmineau, Justine Valérie Magali January 2020 (has links)
The study carried out in this master thesis is part of a larger project led by Energynautics GmbH focusing on renewable energy development in the Caribbean. One of the Caribbean states, consisting of multiple islands, has set a target of 30 % of renewable energy in the power sector by 2030. The first objective of the thesis is to develop optimal generation capacity expansion plans for two different islands of this country, utilizing solar PV generation, which is the only available renewable energy resource. To achieve this objective, three main tasks are identified. The first is the development of an optimal generation capacity expansion plan for the next three years using the optimization tool HOMER Energy. At the beginning only diesel generation is present on the islands. For each study case year, the installed capacity of PV and BESS is optimized and enabling technologies such as curtailment (controllability of PV) and grid-forming inverters are deployed. The second task focuses on the development of a new dispatch strategy, improving on the black box dispatch algorithms built into HOMER. The dispatch strategy minimises the cost of electricity generation and is based on a rolling 48 hours forecasts of the load and PV. It is implemented in MATLAB and linked to HOMER via the built-in MATLAB interface. As HOMER is focused on generation expansion and dispatch and inherently neglects the grid, a grid study is required to assess the stability of the network. This study is the last task of the thesis and is limited to determined steady-state voltage and the asset loading on one of the studied islands through load flow simulations in DIgSILENT PowerFactory. It is shown that there are no major issues even at high PV shares, however, grid performance can be improved if the PV unit is equipped with reactive power capability to control the voltage. A study on the impact of the Q(U)- control and the PQ-capability of the PV and BESS inverters is performed. / Studien som genomförts i detta examensarbete är en del av ett större projekt vilket leds av Energynautics GmbH med fokus på utveckling av förnybar energi i Karibien. En av de Karibiska staterna, bestående av flera öar, har ett mål på 30 % förnybar energi i elkraftssektorn innan 2030. Första syftet med examensarbetet är att utveckla optimala utbyggnadsplaner för produktionskapaciteten för två olika öar i detta land, med användning av solcellsproduktion, vilket är den enda tillgängliga förnybara energikällan. Den första uppgiften är utvecklingen av en optimal utbyggnadsplan för produktionskapaciteten för de kommande tre åren med optimeringsverktyget HOMER Energy. Från början fanns det bara dieselgeneratorer på öarna. För varje studerat år optimeras den installerade kapaciteten av PV och BESS samt aktivering av möjliggörande teknologier som begränsning av PV-produktion och grid-forming växelriktare. Den andra uppgiften fokuserar på utvecklingen av en ny driftsstrategi, förbättring av den basala driftsalgoritm som är inbyggd i HOMER. Driftsstrategin minimerar kostnaden av elproduktionen och är baserad på en 48 timmars prognos av laster och PV. Den är implementerad i MATLAB och kopplad till HOMER via det inbyggda MATLABgränssnittet. Eftersom HOMER fokuserar på produktionsutbyggnad och drift och i praktiken försummar elnätet, krävs en studie av elnätet för att utvärdera stabiliteten av elnätet. Studien av denna sista uppgift i examensarbetet är begränsad till att bestämma spänningen vid jämnviktsläge och den utvärderade lasten på en av de studerade öarna genom belastningsfördelningsberäkning i DIgSILENT PowerFactory. Det visade sig att det inte fanns några stora problem även med stora andelar PV, men elnätets prestanda kan förbättras om PV-omriktarna är utrustade med reaktiv effektstyrning som kontrollerar spänningen. En studie avinverkan från Q(U)-styrning och PQ-kapacitet av PV- och BESS-växelriktare har utförts.
92

Evaluating the Efficient Grid Utilisation Incentive : Through the design of the load flow indicator

Ndayisaba, Chris-Antony, Sammils, Isabelle January 2023 (has links)
The Swedish energy markets inspectorate (Ei) regulates the Swedish DSOs revenue cap, to ensure reasonable prices, efficiency, and quality of supply towards the end users. In combination with directives from the European Union and Sweden's environmental goal, Ei implemented efficient grid utilization to the DSOs revenue cap in 2016. The efficient grid utilization can be divided into two incentives: load flow and network losses. Criticism regarding the load flow incentive, and the indicator used to calculate it, has been raised from the industry. The purpose of this degree project was to investigate the possibilities of a new indicator that also could be affected by the DSOs actions. The project identified four main indicators to test, weighted load factor, utilization factor, adjusted utilization factor and a utilization factor that incorporates all local production units. The indicators were calculated with data from a regional and local grid, provided by the Swedish DSO Ellevio. Other parameter changes such as peaks and seasonal based calculations were also tested. To see the impact DSOs could have on the indicator, with today's regulations, was detected to be through load shaving and shifting, demand side management (DSM). MATLAB was used to test the impact DSM had on the indicators. Further, a load prediction for the years 2023–2035, based on provided historical data, was executed to test the indicators long-term outcome. The project concluded that the regional grid had little to non-impact on the indicators with DSM whilst the local grid resulted in high increased outcome for most indicators. The project continues to conclude to separate indicators for the regional and local grid, to better represent the two grids characteristic and purpose in Swedish society. The adjusted utilization factor was proposed for the regional grid, due to its non-negative impact from installing renewable energy resources, and the weighted load factor for the local grid due to being highly affected by DSM. Lastly, the project concluded that the indicator needs to be changed and further developed for regional DSOs, for them to have the opportunity to affect it.
93

Voltage Stability Analysis of Unbalanced Power Systems

Santosh Kumar, A January 2016 (has links) (PDF)
The modern day power system is witnessing a tremendous change. There has been a rapid rise in the distributed generation, along with this the deregulation has resulted in a more complex system. The power demand is on a rise, the generation and trans-mission infrastructure hasn't yet adapted to this growing demand. The economic and operational constraints have forced the system to be operated close to its design limits, making the system vulnerable to disturbances and possible grid failure. This makes the study of voltage stability of the system important more than ever. Generally, voltage stability studies are carried on a single phase equivalent system assuming that the system is perfectly balanced. However, the three phase power system is not always in balanced state. There are a number of untransposed lines, single phase and double phase lines. This thesis deals with three phase voltage stability analysis, in particular the voltage stability index known as L-Index. The equivalent single phase analysis for voltage stability fails to work in case of any unbalance in the system or in presence of asymmetrical contingency. Moreover, as the system operators are giving importance to synchrophasor measurements, PMUs are being installed throughout the system. Hence, the three phase voltages can be obtained, making three phase analysis easier. To study the effect of unbalanced system on voltage stability a three phase L-Index based on traditional L-Index has been proposed. The proposed index takes into consideration the unbalance resulting due to untransposed transmission lines and unbalanced loads in the system. This index can handle any unbalance in the system and is much more realistic. To obtain bus voltages during unbalanced operation of the system a three phase decoupled Newton Raphson load ow was used. Reactive power distribution in a system can be altered using generators voltage set-ting, transformers OLTC settings and SVC settings. All these settings are usually in balanced mode i.e. all the phases have the same setting. Based on this reactive power optimization using LP technique on an equivalent single phase system is proposed. This method takes into account generator voltage settings, OLTC settings of transformers and SVC settings. The optimal settings so obtained are applied to corresponding three phase system. The effectiveness of the optimal settings during unbalanced scenario is studied. This method ensures better voltage pro les and decrease in power loss. Case studies of the proposed methods are carried on 12 bus and 24 bus EHV systems of southern Indian grid and a modified IEEE 30 bus system. Both balanced and unbalanced systems are studied and the results are compared.
94

Vliv decentrálních zdrojů na provozování distribuční soustavy 110 kV E.ON / The impact of distributed generation on 110 kV distribution system E.ON

Hajdú, Lukáš January 2011 (has links)
This Master´s thesis deals with problematics related to the connection of new decentralized power sources into electrical power grid. Due to advantageous legislative support of these new, especially photovoltaic power sources, a massive amount of these sources have been connected into the power grid between years 2009 and 2010. For theoretical understanding of processes during a steady-state, the initial parts of this paper are focused on a procedure which solves steady-state on every power line mentioned. When we speak of decentralized power sources connection, it is necessary to mention the connected legislative. National distribution grid operators in collaboration with national regulatory commission have decided on a legislative document Rules of distribution grid operation, which puts a set of demands and requirements on applicants wishing to connect a new power source to the grid. The text of this thesis is focused mainly on demands required after the latest change in 1/2010. Practical part of this work deals with verification of new power source influence on a related power grid and meeting the legislatively required demands. The most important demands are voltage change due to new power source operation and its transfer to other voltage levels, higher harmonics injection, power output fluctuation and last, not least, changes in load flow directions. For reasons previously mentioned an analysis is made and possibilities of reducing or removing of these influences are introduced. To achieve these goals, two computer programs, Siemens Sinaut Spectrum and NetCalc are used.