• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 6
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 29
  • 29
  • 29
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Poustevnická kolonie / The hermit colony

Jakubcová, Eva January 2013 (has links)
This construction programme deals with a hermit colony located in the western part of the Vysočina Region. This hermit colony has been established to provide accommodation for women living in this area permanently while offering an opportunity of occasional relaxation for people who are living hectic lives in urban environment. The aim of my project is to design the remaining parts of the colony, i.e. two hermitages and the community’s chapel. A hermitage is a one-storey building intended for one person only. The load-bearing walls of the individual hermitages are designed to be built from different materials (wooden and masonry constructions) whereas the elevational structures of all the buildings are to be the same. The chapel’s wall system combines stone and wood. The chapel will serve solely the purposes of the community. The main objective of my project is to respect and maintain the natural features of the landscape to the maximum extent possible.
12

Environmentálně vyspělý domov důchodců / Environmentally advanced retirement home

Voves, Martin January 2022 (has links)
The subject of my master's thesis is the design of an energy-efficient house for the elderly. The building has three floors. The construction system is made of ceramic blocks filled with glass wool. The building is covered with a flat vegetation roof. The retirement home has 15 apartments, a doctor's office, a common dining area, a common room and offices for administration. A technical concept for the building environment was designed for the building. The dining room, office, lounge and doctor's rooms are forcibly ventilated. The premises are divided into three zones and each zone has its own air handling unit. Heating is provided by two condensing gas boilers and the whole building is heated by radiators. An assessment was made for the design of photovoltaic panels. In the third part, an assessment and research of sources for heating and hot water was prepared.
13

Modélisation dynamique des apports thermiques dus aux appareils électriques en vue d'une meilleure gestion de l'énergie au sein de bâtiments à basse consommation / Dynamic Thermal Modeling of Electrical Appliances for Energy Management of Low Energy Buildings

Park, Herie 15 May 2013 (has links)
Ce travail propose un modèle thermique dynamique des appareils électriques dans les bâtiments basse consommation. L'objectif de ce travail est d'étudier l'influence des gains thermiques de ces appareils sur le bâtiment. Cette étude insiste sur la nécessité d'établir un modèle thermique dynamique des appareils électriques pour une meilleure gestion de l'énergie du bâtiment et le confort thermique de ses habitants.Comme il existe des interactions thermiques entre le bâtiment et les appareils électriques, sources de chaleur internes au bâtiment, il est nécessaire de modéliser le bâtiment. Le bâtiment basse consommation est modélisé dans un premier temps par un modèle simple reposantl'étude d'une pièce quasi-adiabatique. Ensuite, dans le but d'établir le modèle des appareils électriques, ceux-ci sont classés en quatre catégories selon leurs propriétés thermiques et électriques. A partir de cette classification et du premier principe de la thermodynamique, un modèle physique générique est établi. Le protocole expérimental et la procédure d'identification des paramètres thermiques des appareils sont ensuite présentés. Afin d'analyser la pertinence du modèle générique appliqué à des cas pratiques, plusieurs appareils électriques utilisés fréquemment dans les résidences – un écran, un ordinateur, un réfrigérateur, un radiateur électrique à convection et un micro-onde – sont choisis pour étudier et valider ce modèle ainsi que les protocoles d'expérimentation et d'identification. Enfin, le modèle proposé est intégré dans le modèle d'un bâtiment résidentiel développé et validé par le CSTB. Ce modèle couplé des appareils et du bâtiment est implémenté dans SIMBAD, un outil de simulation du bâtiment. A travers cette simulation, le comportement thermique du bâtiment et la quantité d'énergie nécessaire à son chauffage sur une période hivernale, ainsi que l'inconfort thermique dû aux appareils électriques durant l'été, sont observés.Ce travail fournit des résultats quantitatifs de l'effet thermique de différents appareils électriques caractérisés dans un bâtiment basse consommation et permet d'observer leur dynamique thermique et leurs interactions. Finalement, cette étude apporte une contribution aux études de gestion de l'énergie des bâtiments à basse consommation énergétique et du confort thermique des habitants. / This work proposes a dynamic thermal model of electrical appliances within low energy buildings. It aims to evaluate the influence of thermal gains of these appliances on the buildings and persuades the necessity of dynamic thermal modeling of electrical appliances for the energy management of low energy buildings and the thermal comfort of inhabitants.Since electrical appliances are one of the free internal heat sources of a building, the building which thermally interact with the appliances has to be modeled. Accordingly, a test room which represents a small scale laboratory set-up of a low energy building is first modeled based on the first thermodynamics principle and the thermal-electrical analogy. Then, in order to establish the thermal modeling of electrical appliances, the appliances are classified into four categories from thermal and electrical points of view. After that, a generic physically driven thermal model of the appliances is derived. It is established based also on the first thermodynamics principle. Along with this modeling, the used experimental protocol and the used identification procedure are presented to estimate the thermal parameters of the appliances. In order to analyze the relevance of the proposed generic model applied to practical cases, several electrical appliances which are widely used in residential buildings, namely a monitor, a computer, a refrigerator, a portable electric convection heater, and microwave are chosen to study and validate the proposed generic model and the measurement and identification protocols. Finally, the proposed dynamic thermal model of electrical appliances is integrated into a residential building model which was developed and validated by the French Technical Research Center for Building (CSTB) on a real building. This coupled model of the appliances and the building is implemented in a building energy simulation tool SIMBAD, which is a specific toolbox of Matlab/Simulink®. Through the simulation, thermal behavior and heating energy use of the building are observed during a winter period. In addition, thermal discomfort owing to usages of electrical appliances during a summer period is also studied and quantified.This work therefore provides the quantitative results of thermal effect of differently characterized electrical appliances within a low energy building and leads to observe their thermal dynamics and interactions. Consequently, it permits the energy management of low energy buildings and the thermal comfort of inhabitants in accordance with the usages of electrical appliances.
14

Methodology to estimate building energy consumption using artificial intelligence / Méthodologie pour estimer la consommation d’énergie dans les bâtiments en utilisant des techniques d’intelligence artificielle

Paudel, Subodh 22 September 2016 (has links)
Les normes de construction pour des bâtiments de plus en plus économes en énergie (BBC) nécessitent une attention particulière. Ces normes reposent sur l’amélioration des performances thermiques de l’enveloppe du bâtiment associé à un effet capacitif des murs augmentant la constante de temps du bâtiment. La prévision de la demande en énergie de bâtiments BBC est plutôt complexe. Ce travail aborde cette question par la mise en œuvre d’intelligence artificielle(IA). Deux approches de mise en œuvre ont été proposées : « all data » et « relevant data ». L’approche « all data » utilise la totalité de la base de données. L’approche « relevant data » consiste à extraire de la base de données un jeu de données représentant le mieux possible les prévisions météorologiques en incluant les phénomènes inertiels. Pour cette extraction, quatre modes de sélection ont été étudiés : le degré jour (HDD), une modification du degré jour (mHDD) et des techniques de reconnaissance de chemin : distance de Fréchet (FD) et déformation temporelle dynamique (DTW). Quatre techniques IA sont mises en œuvre : réseau de neurones (ANN), machine à support de vecteurs (SVM), arbre de décision (DT) et technique de forêt aléatoire (RF). Dans un premier temps, six bâtiments ont été numériquement simulés (de consommation entre 86 kWh/m².an à 25 kWh/m².an) : l’approche « relevant data » reposant sur le couple (DTW, SVM) donne les prévisions avec le moins d’erreur. L’approche « relevant data » (DTW, SVM) sur les mesures du bâtiment de l’Ecole des Mines de Nantes reste performante. / High-energy efficiency building standards (as Low energy building LEB) to improve building consumption have drawn significant attention. Building standards is basically focused on improving thermal performance of envelope and high heat capacity thus creating a higher thermal inertia. However, LEB concept introduces alarge time constant as well as large heat capacity resulting in a slower rate of heat transfer between interior of building and outdoor environment. Therefore, it is challenging to estimate and predict thermal energy demand for such LEBs. This work focuses on artificial intelligence (AI) models to predict energy consumptionof LEBs. We consider two kinds of AI modeling approaches: “all data” and “relevant data”. The “all data” uses all available data and “relevant data” uses a small representative day dataset and addresses the complexity of building non-linear dynamics by introducing past day climatic impacts behavior. This extraction is based on either simple physical understanding: Heating Degree Day (HDD), modified HDD or pattern recognition methods: Frechet Distance and Dynamic Time Warping (DTW). Four AI techniques have been considered: Artificial Neural Network (ANN), Support Vector Machine (SVM), Boosted Ensemble Decision Tree (BEDT) and Random forest (RF). In a first part, numerical simulations for six buildings (heat demand in the range [25 – 85 kWh/m².yr]) have been performed. The approach “relevant data” with (DTW, SVM) shows the best results. Real data of the building “Ecole des Mines de Nantes” proves the approach is still relevant.
15

Contribution à l'évaluation in situ des performances d'isolation thermique de l'enveloppe des bâtiments / In situ assessment of the thermal insulation performance of building envelopes

Thébault, Simon Romain 27 January 2017 (has links)
Dans un contexte d’économie d’énergie et de réduction des émissions de gaz à effet de serre, de nombreux efforts ont été réalisés en France pour renforcer l’isolation de l’enveloppe des bâtiments afin de contribuer à réduire les consommations de chauffage. Toutefois, il arrive souvent que la performance thermique calculée avant construction ou rénovation ne soit pas atteinte sur le terrain (erreur de calcul, défauts de mise en œuvre, etc.). Or, pour pouvoir généraliser la construction de bâtiments à basse consommation et la rénovation, il faut pouvoir garantir aux maîtres d'ouvrage une performance réelle de leur bâtiment après travaux. Le fait de mesurer in situ la performance intrinsèque d'isolation thermique de l'enveloppe permet de contribuer à cette garantie. Il existe à l’échelle internationale de nombreuses méthodes basées sur le suivi des consommations et des conditions thermiques intérieures et extérieures. Certaines ont déjà fait leurs preuves sur le terrain, mais sont souvent soit contraignantes, soit peu précises. Et surtout, les calculs d’incertitude associés sont souvent rudimentaires. L’objectif de ce travail financé par le CSTB est de consolider scientifiquement une nouvelle méthode de mesure de la qualité d’isolation globale d’un bâtiment à réception des travaux (méthode ISABELE). Dans le premier chapitre, un état de l'art sur les méthodes existantes a été réalisé afin de dégager des pistes d'amélioration sur la base d'une synthèse comparative. La piste prioritaire identifiée porte sur le calcul d'incertitude (un point central du problème). La propagation des erreurs aléatoires par un approche bayésienne ainsi que des erreurs systématiques par une approche plus classique feront l'objet de la méthodologie globale proposée dans le second chapitre. L'une des importantes sources d'incertitude porte sur l'évaluation du débit d'infiltration. La caractérisation de cette incertitude et de l'impact sur le résultat de mesure fera l'objet du troisième chapitre, avec un comparatif de différentes approches expérimentales (règle du pouce, modèles aérauliques, gaz traceur). Enfin, une amélioration de la prise en compte de la dynamique thermique du bâtiment au cours du test sera proposée dans le dernier chapitre. Son fondement repose sur l'adaptation du modèle thermique inverse en fonction du bâtiment et des conditions du test. Pour cela, une sélection parmi une banque de modèles simplifiés est réalisée sur la base de critères statistiques et du principe de parcimonie. Ces différentes dispositions ont été testés sur une large série de mesures menées sur un même bâtiment à ossature bois (chalet OPTIMOB). La robustesse et la précision du résultat de mesure ont ainsi pu être légèrement améliorées. La méthode de calcul du débit d'infiltration, ni trop simple ni trop complexe, a pu également être validée. Enfin, le temps de mesure minimal nécessaire a pu être déterminé en fonction de la classe d'inertie du bâtiment. / The global context of energy savings and greenhouse gases emissions control led to significant efforts in France to boost the thermal insulation in buildings in order to reduce heating consumption. Nevertheless, the stated thermal performance before construction or refurbishment is rarely achieved in practice, for many reasons (calculation errors, defects in materials or workmanship, etc.). Yet, guaranteeing the real thermal performance of buildings on the spot is crucial to enhance the refurbishment market and the construction of energy efficient buildings. To do so, measurement techniques of the intrinsinc thermal insulation performance indicators are needed. Such techniques already exist worldwide, and consist in processing the measurement data from the indoor and outdoor thermal conditions and the heat consumption. Some of them have already proved themselves in the field, but are either binding or very imprecise. And above all, the related uncertainty calculations are often rough. The objective of this thesis funded by CSTB is to consolidate a novel measurement method of the thermal insulation quality of a whole building after reception of work (ISABELE method). In the first chapter, a state of the art of the existing methods allows to identify possible ways to pursue this goal from a comparative synthesis. The primary reflection is about the uncertainty calculation method (which is a central issue). The second chapter presents a global methodology to combine the propagation of random and systematic errors from bayesian and classical approaches. One of the most important uncertainty sources deals with the infiltration air flow evaluation during the test. The third chapter investigates the characterization of this uncertainty, as well as its impact on the final result, depending on the chosen experimental approach (rule of thumb, simplified aeraulic models, tracer gases). Lastly, an improvement of the inclusion of the bluiding thermal dynamics during the test will be proposed in the last chapter. The basis of this improvement is to adapt the inverse model according to the building type and the test conditions. To do so, the proposed algorithm selects a model form a variety of simplified greybox models based on statistical criteria and parcimony. All these contributions have been tested on a large serie of measurements on a same timber-framed building (OPTIMOB shed). The robustness and precision of the results have been slightly improved. The intial infiltration air flow calculation, neither too simple of too complicated, has also been validated. Finaly, a better ordrer of magnitude of the minimal test duration has been determined, depending on the building inertia.
16

Validation expérimentale de modèles : application aux bâtiments basse consommation / Empirical validation of models : application to low-energy buildings

Bontemps, Stéphanie 02 December 2015 (has links)
Avec la généralisation de la construction des bâtiments basse consommation, passifs et à énergie positive, mais aussi la rénovation du parc existant, il est indispensable d’avoir recours à la simulation pour évaluer, entre autres, les performances énergétique et environnementale atteintes par ces nouveaux bâtiments. Les attentes en termes de garantie de performance énergétique étant de plus en plus importantes, il est primordial de s’assurer de la fiabilité des outils de simulation utilisés. En effet, les codes de simulation doivent être capables de représenter le comportement de ces nouveaux types de bâtiments de la façon la plus juste et fidèle possible. De plus, les incertitudes liées aussi bien aux paramètres de conception qu’aux différentes sollicitations ainsi qu’aux usages des bâtiments doivent être prises en compte pour pouvoir garantir la performance du bâtiment sur sa durée de vie.Cette thèse s’est intéressée à la validation expérimentale de modèles appliquée à un bâtiment de type cellule test. Cette méthodologie de validation se déroule en plusieurs étapes au cours desquelles on évalue la qualité du modèle en termes de justesse et de fidélité. Plusieurs cas d’études ont été menés sur lesquels nous avons pu identifier les paramètres les plus influents sur la sortie du modèle, examiner l’influence du pas de temps sur le processus de validation expérimentale, analyser l’influence de l’initialisation et confirmer l’aptitude de la méthodologie à tester le modèle. / Construction of low, passive and positive energy buildings is generalizing and existing buildings are being renovated. For this reason, it is essential to use simulation in order to estimate, among other things, energy and environmental performances reached by these new buildings. Expectations regarding guarantee of energy performance being more and more important, it is crucial to ensure the reliability of simulation tools being used. Indeed, simulation codes should reflect the behavior of these new kinds of buildings in the most consistent and accurate manner. Moreover, the uncertainty related to design parameters, as well as solicitations and building uses have to be taken into account in order to guarantee building energy performance during its lifetime.This thesis investigates the empirical validation of models applied to a test cell building. This validation process is divided into several steps, during which the quality of the model is evaluated as far as consistency and accuracy are concerned. Several study cases were carried out, from which we were able to identify the most influential parameters on model output, inspect the influence of time step on the empirical validation process, analyze the influence of initialization and confirm methodology’s ability to test the model.
17

Energianalys av Sveriges största skola byggd med passivhusteknik / Energy analysis of Sweden´s largest school built with passive house technique

Music, Nermina, Lund, Hilda January 2018 (has links)
För att uppnå Sveriges energimål har servicesektorn börjat bygga energieffektiva byggnader. I detta examensarbete har energiberäkningar med hjälp av VIP-Energy utförts för Elmeskolan som är byggd enligt passivhusteknik. Resultatet av energiberäkningen har jämförts med kraven enligt BBR 22 och 25 och passivhusstandarden. Det visade sig att kraven för BBR och passivhusstandarden uppfylldes. Även en beräkning av energiprestanda för BBR 22 och 25 med avseende på bergvärme och fjärrvärme har tagits fram med hjälp av definitioner enligt Boverkets byggregler. Energiprestandan för bergvärme visade sig vara lägre än för fjärrvärme. Tre LCC-kalkyler har utförts med hjälp av en Excel-mall. Den beräknade energiprestandan för Elmeskolan samt det maximala kravet för energiprestanda för passivhusstandarden och BBR 22 har legat till grund för kalkylen. Kalkylen resulterade i att Elmeskolans energikostnad var en fjärdedel i jämförelse med kravet för BBR 22. Syftet med denna studie är att resultatet ska påvisa fördelarna med att uppföra byggnader med passivhusteknik samt påvisa energieffektiviteten för ett passivhus. / In order to achieve Sweden's energy goals, the service sector needs to build energy-efficient buildings. Therefore, the national board of housing, building and planning proposed building regulations called BBR that consists of requirements and general recommendations for both new and existing building and contains multidimensional aspects including energy management in the building. Passive house building is also another promising solution to approach an energy efficient building. The main aim of this study is to assess the energy performance of a case study building according to the both BBR and passive house building criteria. Correspondingly, Elmeskolan, which has been built based on passive house standards, is chosen as the case study and a model is developed using a building energy-modelling program, VIP-Energy. The result of the energy calculation has been compared with the requirements of BBR 22 and 25 and the Passive House Standards. The study shows that the requirements for BBR and Passive House Standards were met for the case studied building. The primary energy demand of the heat supply system in the building is assessed by considering either geothermal or district heating system according to the Boverket’s energy management building regulations. It is concluded that the primary energy demand in case of using geothermal system is lower than district heating system to supply building heating demand. A simplified LCC analysis has been considered in this study due to the passive house standard and BBR 22 and 25 building regulations. The results show energy cost of the case studied building that is built based on passive house criteria is 25 % of total energy cost of similar building that built based on BBR 22 requirements. The results show the benefits of passive house requirements in comparison with BBR regulations for the case studied building in terms of thermo-economic objectives.
18

Polyfunkční dům / Multifunctional building

Kostečka, Jan January 2020 (has links)
The project documentation, processed in the framework of the diploma thesis, solves the new building of the multifunctional house in Žďár nad Sázavou. The building is made of traditional brick technology of brick fittings, with insulation, ceilings are reinforced concrete monolithic, roof sloping in two variants. Commercial premises are located on the ground floor on the south side. Furthermore, on the floor there are technical facilities for offices and storage space for housing units and offices. On the next floors there are always 3 residential units. The building is located on flat terrain in the rapidly developing part of the city. The building envelope and individu-al structures are designed to the entire object it was as energy- consuming as possible, and do not pump irreparably by nature its natural resources in a larger quantity than necessary.
19

Modélisation dynamique tridimensionnelle avec tache solaire pour la simulation du comportement thermique d’un bâtiment basse consommation / A three dimensional thermal room and sun patch model to simulate the transient behaviour of an energy efficient building

Rodler, Auline 25 November 2014 (has links)
Cette thèse s’inscrit dans le contexte du développement de Bâtiments Basse Consommation. La conception de telles constructions les rend sensibles aux sollicitations internes. Aussi, les outils de thermique du bâtiment existants ne sont pas adaptés pour simuler assez fidèlement ce type de bâtiments, si bien qu’un modèle tridimensionnel et dynamique a été développé ici. Celui-ci présente plusieurs particularités : il s’appuie sur une discrétisation spatiale optimisée des parois, la tache solaire y est localisée et l’intégration des dynamiques des conditions environnementales est assurée par un solveur numérique à pas de temps adaptatif et un seul nœud d’air est considéré. La validation du modèle s’est suivant une confrontation avec des mesures en conditions réelles réalisées dans une cellule de BESTlab d’EDF R&D. Un suivi visuel de la tache solaire a permis de confirmer sa bonne localisation par notre modèle. Des mesures de température en surface complétées par des cartographies thermographiques ont été comparées aux champs de températures simulés, montrant une bonne concordance. Les comparaisons de températures d’air mesurées et simulées ont montré des résidus ne dépassant pas 1,5 ˚C, pour des erreurs moyennes de 0,5 ˚C. La pertinence des deux principales innovations du modèle a été ensuite démontrée : l’utilisation d’entrées échantillonnées à la minute associées à un solveur à pas de temps adaptatif permet de minimiser les erreurs de simulation : en mi-saison, les résidus maximaux sont respectivement de 1 ˚C et 2 ˚C pour des entrées à la minute et à l’heure. En hiver, les températures d’air simulées tendent à plus osciller autour de la consigne quand le pas d’échantillonnage des entrées s’allonge. Deux modèles unidimensionnels, représentatifs de modèles courants, M1D,sol diluant le rayonnement solaire sur le sol seul et M1D,parois le distribuant de façon homogène sur les parois au prorata de la taille de la tache solaire censée les frappées, ne dégradent que légèrement la précision des calculs de température d’air. Cependant, ces modèles 1D ne permettent pas de calcul des champs de températures sur les parois si bien qu’ils présentent des erreurs locales dépassant 20 ˚C aux endroits touchés par la tache solaire. Enfin en hiver, le modèle 3D permet de prédire des consommations de chauffage surestimées de 6,5 % quand M 1D,parois les surestime de 11 % et M1D,sol de 22 %. Les améliorations apportées par notre modèle ont été confirmées pour d’autres types de cellules. D’ailleurs des écarts plus importants entre M1D,sol et le modèle 3D ont été observés pour une cellule dont parois et sol ont des compositions très différentes, alors que l’orientation a aussi un impact. Ce travail confirme la nécessité de représenter plus finement les phénomènes physiques pour des locaux fortement isolés. Des améliorations sont à intégrer, comme la description de l’anisothermie de l’air. / Low energy building constructions become sensitive to internal gains : any internal heating source has an impact on the envelope. Therefore, it is important to evaluate the performance of current transient thermal models when adapted to low energy buildings. This work describes a numerical model to simulate a single room, using a refined spatial three-dimensional description of heat conduction in the envelope but a single air node is considered. The model has been developed for environmental conditions that vary over short time-steps and has integrated the projection of solar radiation through a window onto interior walls : the sun patch. The validation of the model has been done through a detailed comparison between model and measurements. The in situ experiment has been carried out in one of the BESTlab cells (EDF R&D). The sun patch has been followed by a camera to validate its calculated position and surface. Temperature measurements by thermocouples and by thermal cameras have been compared to the models outputs. Differences between air and surface temperatures measured and simulated were never above 1.5 ˚C and mean errors reached 0.5 ˚C. The two innovations of the model have then be proven. Using minute wise weather data and inputs associated to an adaptative solver, enabled to pull down simulation errors : in May maximal differences rised from 1 ˚C to 2 ˚C for respectivelly one minute and hourly wise inputs. More important errors are seen in summer whereas in winter, air temperatures simulated tend to more fluctuate around the set up temperature when the sampling step gets longer. Two one dimensional models, close to traditional taken simulation tools, were used. Model M 1D,sol supposed the incoming radiation to reach only the floor. A 1D model with sun patch movement, called 1D,parois , was also used. These two models evaluated the air temperature with an acceptable error. However, their surface temperatures were still subject to important errors. Thus, for temperature surfaces evaluation, both 1D model presented differences up to 20 ˚C for surfaces touched by the sun patch. In winter, the 3D model can predict heating energy consumptions overestimated by 6.5 % when M 1D,parois overestimated them by 11 % and M1D,sol by 22 %. The improvements brought by our model have been proven also for other cells with different thermal masses. For these cells, differences between M1D,sol and the 3D model could reach 4.5 ˚C. Differences seemed to be more important for low thermal mass cells, and the orientation of the building had a strong impact. This work has confirmed the necessity of representing more accuratelly the descriptions of the enveloppe for strongly insulated rooms. To improve the model, the anisothermal hypotheses of the air should be considered.
20

Polyfunkční dům areálu Slavkov / Mixed-use building in the Slavkov complex

Milota, Martin January 2022 (has links)
The building in a question is a new build mixed-use building. It is situated in industrial area of Slavkov u Brna and is intended for employees of this area. In the underground floor is situated collective garage for 18 personal automobiles. First floor is designed for retail sale. Specifically general store, boutique and cafe. In the second and third floor are accommodation units for area employees. Specifically 12 accommodation units. Building has a flat roof with asphalt strip coating. The load-bearing system of the building is designed as a reinforced concrete skeleton, THERM-type bricks are used for the construction while thermal comfort is achieved by a certified external thermal insulation composite system (ETICS) featuring façade polystyrene. There is parking space area in front of the building.

Page generated in 0.0615 seconds