• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 1
  • Tagged with
  • 98
  • 98
  • 98
  • 95
  • 95
  • 94
  • 77
  • 33
  • 32
  • 32
  • 28
  • 27
  • 22
  • 15
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avalia??o da pr?-carga e torque de remo??o de 3 tipos de parafusos de fixa??o de pilares para pr?teses unit?rias implanto-suportadas

St?ker, Rafael Augusto 21 March 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:36Z (GMT). No. of bitstreams: 1 346916.pdf: 3129380 bytes, checksum: 19e63ec2b78c6ba60d946c3cb69dd9c4 (MD5) Previous issue date: 2006-03-21 / In?meros autores consideram os problemas mec?nicos de fratura ou afrouxamento de componentes como sendo uma das principais causas de insucessos em reabilita??es implanto-suportadas, estando muitos destes problemas relacionados a uma tens?o insuficientemente induzida ao parafuso para fixa??o de pilar transmucoso, tamb?m conhecida como pr?-carga. Assim, este estudo in vitro teve como objetivo comparar a pr?-carga de 3 tipos diferentes de parafuso para fixa??o de pilares transmucosos utilizados em pr?teses unit?rias implanto-suportadas atrav?s de extensiometria e valores de torque de remo??o. Foram utilizados 3 implantes de hex?gono externo (Conex?o?, Sistemas de Pr?tese Ltda., S?o Paulo, Brasil) com 4,0mm de di?metro por 15mm de comprimento, sendo que cada um recebeu um pilar transmucoso tipo Cera One? para pr?tese unit?ria cimentada, que foi fixado ao implante com seu respectivo parafuso de ouro (Grupo A), tit?nio (Grupo B) e tit?nio com tratamento superficial (Ti-Tite?) (Grupo C). Dez parafusos de cada tipo foram fixados com um torque de 30,07?0,28Ncm e mantidos em posi??o por 5 minutos. Ap?s a fixa??o, foi avaliado o valor de pr?-carga produzido com a utiliza??o de extensiometria e uma c?lula medidora. Para a medi??o do torque inicial e do torque de remo??o foi utilizado um dispositivo eletr?nico de controle de torque. Os parafusos de ouro apresentaram os maiores valores de pr?-carga (131,72?8,98N), depois os de tit?nio com tratamento de superf?cie (97,78?4,68N) e os de tit?nio apresentaram os menores valores (37,03?5,69N). Para os valores de torque de remo??o foram encontrados os seguintes resultados: ouro: 17,64?1,12Ncm; tit?nio: 18,75?1,89Ncm; tit?nio com tratamento de superf?cie: 16,43?1,33Ncm. Ap?s an?lise de vari?ncia (ANOVA, p<0,05) e o teste estat?stico de Tukey (p<0,05) foram encontradas diferen?as significativas entre os 3 grupos tanto para os valores de pr?-carga como para os de torque de remo??o. Os resultados do presente estudo sugerem que os parafusos de ouro s?o os mais indicados para que se atinja uma maior longevidade da uni?o pilar-implante e conseq?entemente da restaura??o prot?tica em vista dos maiores valores de pr?-carga produzidos
62

Avalia??o do t?ntalo ap?s tratamento de superf?cie com oxida??o por plasma eletrol?tico (PEO)

Goularte, Marcelo Augusto Pinto Cardoso 24 March 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:39Z (GMT). No. of bitstreams: 1 466188.pdf: 3447258 bytes, checksum: 508bf181d5a5fbbd572dfa7dfa3c800a (MD5) Previous issue date: 2014-03-24 / Every year scientists and biomedical manufacturers bring to the market new biocompatible materials to use as prosthetic devices for the human body. Following that trend, oral implants manufactured with a Tantalum alloy started to be marketed in 2010 by a top orthopedic company. Although this metal has already been tested in dentistry and did not show satisfactory results from an experimental as well as a clinical standpoint in the past, the lack of a successful record was due to a poor comprehension of many important factors involved in the Osseointegration phenomenon. From the fixture design to the understanding of bone biology, the years of research have shown that survival and success in oral implantology is much more than the alloy can tell. And since bone histology has proved that Tantalum has a good healing response, we decided to subject this metal to a surface treatment similar to those regularly applied to Titanium fixtures. Using an especially PEO (Plasma Electrolytic Oxidation) devised protocol we have tried to evaluate the production of a surface oxidation and salt deposition on the metal surface and verify them using SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-Ray Detector or EDX). For that matter, four groups were prepared: Group 1 non-altered Tantalum metal sheets surfaces; Group 2 Tantalum metal sheets exposed to PEO for 1 minute; Group 3 Tantalum metal sheets exposed to PEO for 3 minutes; Group 4 Tantalum metal sheets exposed to PEO for 5 minutes. The results were very satisfactory regarding salt deposition and surface modification and similar to those already seen on Titanium after anodization. / A cada ano, cientistas e empresas biom?dicas trazem ao mercado novos materiais biocompat?veis para o uso em dispositivos prot?ticos para o corpo humano. Seguindo esse prop?sito, implantes dent?rios fabricados com uma liga de T?ntalo foram introduzidos no mercado em 2010 por uma empresa l?der em produtos ortop?dicos. Embora esse metal j? tenha sido utilizado sem muito sucesso tanto do ponto de vista experimental quanto clinico, na odontologia, a falta de uma resposta satisfat?ria foi devido ? pouca compreens?o de muitos fatores importantes envolvidos no fen?meno da Osseointegra??o. Do desenho do implante ao entendimento da biologia ?ssea, os anos de pesquisas mostraram que a sobreviv?ncia e o sucesso dos implantes dent?rios s?o muito mais do que uma liga met?lica possa representar. E j? que a histologia ?ssea tem mostrado que o T?ntalo tem uma boa resposta cicatricial, n?s decidimos submeter esse metal a um tratamento superficial similar ?queles normalmente utilizados nos implantes de Tit?nio. Usando especialmente um protocolo desenvolvido para anodiza??o PEO (Oxida??o por Plasma Eletrol?tico), n?s tentamos avaliar a produ??o de oxida??o superficial e deposi??o de sais sobre a superf?cie do metal e verificamos os resultados no MEV (Microsc?pio Eletr?nico de Varredura) e o EDS (Espectroscopia por Dispers?o de Energia Raio-X). Para a pesquisa, quatro grupos foram preparados: Grupo 1 L?minas de T?ntalo n?o tratadas; Grupo 2 L?minas de T?ntalo expostas ao PEO por 1 minuto; Grupo 3 - L?minas de T?ntalo expostas ao PEO por 3 minutos; Grupo 4 - L?minas de T?ntalo expostas ao PEO por 5 minutos. Os resultados foram muito satisfat?rios ao considerar a deposi??o de sais e modifica??o superficial, muito similar ?queles j? vistos no Tit?nio depois de exposto ao processo de anodiza??o.
63

An?lise comparativa da precis?o de adapta??o entre componentes UCLA e implante de um mesmo sistema

Bondan, Jo?o Lopes 12 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:40Z (GMT). No. of bitstreams: 1 390167.pdf: 8479233 bytes, checksum: 78f267d7711851d94f32594d0a86c23d (MD5) Previous issue date: 2006-12-12 / O objetivo deste estudo foi avaliar a precis?o de adapta??o entre componentes UCLA e implante de um mesmo sistema (Neodent). A an?lise foi atrav?s da avalia??o da fenda vertical e da discrep?ncia horizontal da interface implante-UCLA por microscopia eletr?nica de varredura (MEV), das mensura??es em locais indicados. Para a compara??o dos resultados, foi utilizado o procedimento de an?lise de vari?ncia (Anova-Oneway) e o procedimento posterior de Tukey, ao n?vel de signific?ncia de 5%. Os resultados mostraram que os componentes UCLA avaliados possuem diferen?as significantes em diversos pontos avaliados. Essa variabilidade nos resultados podem interferir na efic?cia de uso desses componentes, nos resultados cl?nicos e na sua previsibilidade
64

Avalia??o da transmit?ncia direta de resinas compostas por meio de espectrofotometria de UV-vis?vel

Masotti, Alexandre Severo 21 January 2005 (has links)
Made available in DSpace on 2015-04-14T13:30:41Z (GMT). No. of bitstreams: 1 330875.pdf: 1305514 bytes, checksum: 089a799a5a900dcf1c58a4ca2f0e1710 (MD5) Previous issue date: 2005-01-21 / Este estudo avaliou as porcentagens de Transmit?ncia direta (Td) das resinas compostas microh?bridas Charisma F, Solitaire II (Heraeus Kulzer ), Intens e Tetric Ceram (Ivoclar Vivadent) e nanoparticuladas Esthet-X (Dentsply De trey) e Filtek Supreme (3M Espe) nas cores Vita A3 (Dentina) e transl?cido (Esmalte), ou seus correspondentes. Foram confeccionados tr?s corpos-de-prova para cada material e cor, de formato quadrangular com 12x12 mm de lado e espessura de 1 mm. Ap?s fotoativa??o, foram realizadas tr?s leituras por corpo-de-prova em espectrofot?metro de UV-vis?vel HP 8453 (Hewlett-Packard), com temperatura e umidade controladas (22?2?C/50?5%). Os ?ngulos de incid?ncia e leitura em 0? / 0? foram utilizados para os comprimentos de onda de 400 a 700 nm. Os espectros obtidos foram analisados quanto ao percentual m?dio de Td para todo o espectro, em intervalos de 20 nm, e nos comprimentos de onda de 400, 560 e 700 nm. Atrav?s de ANOVA e teste de Tukey (p=0,01) encontrou-se que a resina composta Charisma obteve as maiores porcentagens de Td em todos os espectros, exceto para a cor Esmalte em 700 nm, que ficou abaixo da resina composta Esthet-X cor Esmalte. O teste t-Student demonstrou serem significativamente maiores os percentuais de Td para os espectros das cores Transl?cido, exceto para as resinas compostas Supreme, em que n?o diferiram, e Charisma, com porcentagens de Td significativamente maiores para a cor Dentina. Por meio de teste n?o param?trico de Friedman verificou-se que todas as resinas compostas estudadas demonstraram aumento significativo de Td com o aumento do comprimento de onda, com exce??o da resina composta Solitaire, cores Dentina e Esmalte, que n?o demonstrou diferen?as significativas nos comprimentos de onda de 560 e 700 nm.
65

Efeito da usinagem e de procedimentos p?s-usinagem na superf?cie de materiais odontol?gicos para CAD/CAM

Nunes, Laura Smidt 08 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-07-14T16:57:14Z No. of bitstreams: 1 DIS_LAURA_SMIDT_NUNES_PARCIAL.pdf: 228259 bytes, checksum: 74df0dbd4064a00e8b0071f07e6d7ecf (MD5) / Made available in DSpace on 2016-07-14T16:57:14Z (GMT). No. of bitstreams: 1 DIS_LAURA_SMIDT_NUNES_PARCIAL.pdf: 228259 bytes, checksum: 74df0dbd4064a00e8b0071f07e6d7ecf (MD5) Previous issue date: 2016-03-08 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The aim of the study was to evaluate the surface roughness and analyze the surface topography of five different ceramics, a resin composite and two polymers for CAD/CAM after milling and post milling procedures. Blocks of Mark II, IPS Empress CAD, IPS e.max CAD, Enamic, Lava Ultimate, Suprinity, CAD-Temp and CAD-Waxx were milled in CEREC MCXL system. The surface roughness (Ra; ?m) was measured before and after millig procedures, polishing and glaze (when indicated) followed by analysis by SEM and AFM. The results were subjected to statistical tests (one-way ANOVA for repeated measures and Tukey HSD and one-way ANOVA also with Post-Hoc Tukey, respectively) with a significance level of 5% (?=0.05). The milling step significantly increased surface roughness in all tested materials (p<0.05). Mechanical polishing was able to reduce the roughness generated by grinding, requiring the glazing step only in partially crystallized ceramic (IPS e.max CAD and Suprinity). In other materials (Mark II, IPS Empress CAD, Lava Ultimate, Enamic, CAD- Temp and CAD-Waxx) mechanical polishing was enough to achieve similar surface roughness values of the smoothness of the blocks directly from manufacturers. The study suggests that the glaze step can be suppressed in materials completely crystallized and/or polymerized by the manufacturer, these having no statistically significant difference when it's just done mechanical polishing. / O objetivo do estudo foi avaliar a rugosidade superficial e analisar a topografia de superf?cie de cinco diferentes cer?micas, um comp?sito resinoso e dois acr?licos para CAD/CAM ap?s usinagem e procedimentos p?s-usinagem. Blocos de Mark II, IPS Empress CAD, IPS e.max CAD, Enamic, Lava Ultimate, Suprinity, CAD-Temp e CAD- Waxx foram usinados no sistema CEREC MCXL. A rugosidade superficial (Ra; ?m) foi aferida antes e ap?s os procedimentos de usinagem, polimento e glaze (quando indicado) seguidos de an?lises em MEV e MFA. Os resultados foram submetidos a testes estat?sticos (teste one-way ANOVA para medidas repetidas e Tukey HSD e ANOVA one-way tamb?m com Post-Hoc Tukey, respectivamente) com n?vel de signific?ncia de 5% (?=0,05). A etapa de fresagem aumentou significativamente a rugosidade superficial em todos os materiais testados (p<0,05). O polimento foi capaz de reduzir a rugosidade gerada pela usinagem, sendo necess?ria a etapa de glazeamento apenas para cer?micas parcialmente cristalizadas (IPS e.max CAD e Suprinity). Nos demais materiais (Mark II, IPS Empress CAD, Lava Ultimate, Enamic, CAD-Temp e CAD-Waxx) o polimento mec?nico foi suficiente para atingir valores de rugosidade superficial similares a lisura dos blocos provenientes diretamente dos fabricantes. O estudo sugere que a etapa de glaze pode ser suprimida nos materiais j? provenientes do fabricante completamente cristalizados e/ou polimerizados, nestes n?o possuindo diferen?a estatisticamente significativa quando apenas ? realizado polimento mec?nico.
66

For?a m?xima de carregamento de facetas oclusais minimamente invasivas confeccionadas por CAD/CAM

Petry Filho, Carlos Jos? 29 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-10-20T16:22:58Z No. of bitstreams: 1 DIS_CARLOS_JOSE_PETRY_FILHO_COMPLETO.pdf: 1014403 bytes, checksum: 0b1589dd556d94c26d4d0e8e3df24260 (MD5) / Made available in DSpace on 2016-10-20T16:22:58Z (GMT). No. of bitstreams: 1 DIS_CARLOS_JOSE_PETRY_FILHO_COMPLETO.pdf: 1014403 bytes, checksum: 0b1589dd556d94c26d4d0e8e3df24260 (MD5) Previous issue date: 2016-03-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Objective: The aims of this study were evaluate and compare the maximum load strength of the following materials: nanoceramic resin, lithium dissilicate ceramic and zirconium dioxide-reinforced lithium silicate ceramic when used as occlusal veneers in thicknesses recommended by the manufacturer and/or reduced to 0.6 mm, and the occurrence of fracture and fracture types. Materials and Method: Fifty six human molars extracted were randomly divided into 7 groups according to the material and thickness: Control group; L15 and L06 groups (Lava Ultimate), E15 and E06 (e.max CAD) and S10 and S06 (Suprinity). Each material was used in two thicknesses, the minimum thickness recommended by the manufacturer and 0.6mm. All restorations were made using CAD/CAM CEREC system. After milling, all samples were treated according to manufacturer?s recommendations and etched with hydrofluoric acid and silane when indicated. For teeth etching it was used 37% phosphoric acid for 15 seconds selectively enamel, washed for 30 seconds with water and dried with compressed air. The adhesive used was Single Bond Universal, applied actively for 20 seconds. For the cementation was used the dual cement Relyx Ultimate. Results: There was a statistically significant difference in the relationship between the material used and the maximum load strength. There was no significant difference between material and thickness within the groups. The largest recorded charging load average was 3428.25 N at Control Group however without statistically difference from the L15 group 2995.75 N. E15 groups, E06, S10 and S06 showed no statistically significant difference, the lowest average was recorded in group S06 1330.68 N. Conclusions: Within the limitations of this in vitro study, it is possible to concluded that material interfere in the maximum power load in occlusal veneers, however reducing the thickness of these materials does not affect the maximum force recorded charging, all materials recorded loading force greater than that recorded in natural occlusion. / Objetivo: O objetivo deste estudo foi avaliar e comparar a for?a m?xima de carregamento dos seguintes materiais: resina nanocer?mica, cer?mica dissilicato de l?tio e a cer?mica silicato de l?tio refor?ada por di?xido de zirc?nio quando utilizadas como facetas oclusais em espessuras recomendadas pelo fabricante e com espessura reduzida de 0,6 mm, assim como avaliar os tipos e frequ?ncia de fraturas ocorrentes. Materiais e m?todo: Aleatoriamente 56 terceiros molares extra?dos h?gidos foram divididos em 7 grupos de acordo com as vari?veis material e espessura: grupo Controle (dente h?gido); grupos L15 e L06 (Lava Ultimate) com 1,5 mm e 0,6 mm respectivamente, E15 e E06 (e.max CAD) com 1,5mm e 0,6mm respectivamente e S10 e S06 (Suprinity) com 1mm e 0,6 mm respectivamente. Cada material foi utilizado em duas espessuras, a espessura m?nima recomendada pelo fabricante e 0,6mm. Todas as restaura??es foram confeccionadas utilizando o sistema CAD/CAM CEREC. As pe?as receberam o tratamento p?s fresagem de acordo com as recomenda??es dos fabricantes. Para condicionamento dos dentes foi utilizado ?cido fosf?rico 37% por 15 segundos de forma seletiva em esmalte, lavados por 30 segundos com ?gua corrente e secos com jato de ar. O adesivo utilizado foi Single Bond Universal, aplicado de forma ativa por 20 segundos. Para a cimenta??o foi utilizado o cimento resinoso dual Relyx Ultimate. Resultados: Houve diferen?a estatisticamente significativa na rela??o entre o material utilizado e a for?a m?xima de carregamento. A maior m?dia de carga de carregamento registrada foi no grupo Controle 3428,25 N por?m n?o diferiu estatisticamente do grupo L15, 2995,75 N. Os grupos E15, E06, S10 E S06 n?o apresentaram diferen?a estat?stica significativa, a menor m?dia foi registrada no grupo S06 1330,68 N. Conclus?es: Dentro das limita??es de um estudo in vitro conclu?mos que o material interfere na for?a m?xima de carregamento em facetas oclusais. No entanto, a redu??o das espessuras destes materiais n?o interferiu na for?a m?xima de carregamento registrada quando comparado ? indica??o do fabricante. Foi poss?vel observar que todos os materiais testados resistiram a uma for?a de carregamento superior ? registrada em oclus?o natural descrito na literatura.
67

An?lise comparativa do desajuste marginal de infra-estruturas de pr?tese fixa pilares micro-unit com o uso de retificadores manuais

Alonso, Fernando Rizzo 17 January 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:15Z (GMT). No. of bitstreams: 1 399361.pdf: 8314993 bytes, checksum: a3c46db6ec5de11b04392bd9c5ca0dce (MD5) Previous issue date: 2008-01-17 / O crescente uso das pr?teses implanto-suportadas aumentou a preocupa??o com a precis?o de adapta??o, j? que a adapta??o passiva ? um dos fatores fundamentais para o sucesso longitudinal dessas reabilita??es prot?ticas. O objetivo deste trabalho foi avaliar o desajuste marginal de infra-estruturas met?licas de pr?tese fixa sobre implantes, antes a ap?s a retifica??o manual, como o teste do parafuso ?nico, utilizando como grupo controle cilindros pr?-usinados. Foram confeccionadas 10 infra-estruturas em liga de cobalto-cromo (Co-Cr), simulando uma pr?tese fixa de tr?s elementos sobre dois implantes. Para isso, utilizou-se uma matriz met?lica simulando a disposi??o cl?nica de implantes osseointegrados na regi?o dos dentes 14 e 16, contendo pilares Micro-Unit. Cinco infra-estruturas foram confeccionadas com cilindros pr?-usinados. As outras cinco foram confeccionadas com cilindros calcin?veis, que ap?s avalia??o inicial, sofrem retifica??o manual das bordas de assentamento do cilindro ap?s fundi??o, formando o terceiro grupo. Todas as infra-estruturas receberam soldagem a laser. As leituras do desajuste marginal foram realizadas atrav?s de imagens do microsc?pio eletr?nico de varredura, utilizando a t?cnica do parafuso ?nico, totalizando 25 medi??es em cada cilindro. As m?dias de desajuste marginal de cada cilindro foram utilizadas para a an?lise estat?stica. A an?lise de vari?ncia com n?vel de signific?ncia de 5% foi utilizada para avaliar o efeito da retifica??o manual entre os tr?s grupos testados, nos cilindros com e sem parafuso. Foi conclu?do que os procedimentos de retifica??o manual n?o alteraram significativamente os valores de desajuste marginal nas infra-estruturas fundidas em Co-Cr, ou seja, n?o aumentaram a passividade das pe?as prot?ticas sobre os pilares.
68

Retra??o de caninos superiores com dois tipos de el?sticos em cadeia

Giollo, Luciano Dias 16 January 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:18Z (GMT). No. of bitstreams: 1 400719.pdf: 3832868 bytes, checksum: 7f7e5e2d5a4148bbc3e382e8c43c4bfc (MD5) Previous issue date: 2008-01-16 / O objetivo deste estudo foi avaliar o fechamento dos espa?os na retra??o dos caninos permanentes superiores com dois tipos de el?stico em cadeia distintos (el?sticos em cadeia Memory e Convencional ) determinando: a diferen?a m?dia do movimento dent?rio e a perda de ancoragem dos primeiros molares permanentes superiores. A amostra constituiu-se de 15 pacientes portadores de maloclus?o de Classe II divis?o 1 de Angle, com m?dia de idade de 17anos e 5 meses, sendo 4 do g?nero masculino e 11 do feminino, e todos foram submetidos ? extra??o de dois primeiros pr?-molares superiores. A retra??o dos caninos superiores foi realizada com el?stico em cadeia Convencional, na hemiarcada direita, e com el?stico em cadeia tipo Memory, na esquerda, com for?a de 150 g. A distaliza??o dos caninos foi avaliada a cada 3 semanas at? esta ter sido completada ou num per?odo m?ximo de 3 reavalia??es. Em cada uma destas consultas, foi obtido modelo de gesso a partir de moldagens com alginato. A avalia??o da quantidade m?dia do fechamento dos espa?os a cada 3 semanas foi feita em 4 locais diferentes (3 entre canino e pr?-molar e 1 entre canino e molar) e a perda de ancoragem medida entre o primeiro molar permanente e o ponto mais medial da terceira ruga palatina nos modelos de gesso. Os resultados demonstraram maior movimenta??o com el?sticos Memory, em uma das medidas de fechamento de espa?os. Al?m disso, essa tend?ncia limitou-se ?s tr?s primeiras semanas de tratamento, perdendo a validade ao longo do per?odo de retra??o de caninos superiores permanentes. Ocorreu perda de ancoragem para ambos os el?sticos, no entanto, sem diferen?a estat?stica entre eles.
69

Compara??o de propriedades mec?nicas e do conte?do de carga de cinco resinas compostas com nanopart?culas

Pires, Luiz Antonio Gaieski 31 March 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:19Z (GMT). No. of bitstreams: 1 402875.pdf: 1268537 bytes, checksum: d69e79b0f145ba87098e8a6bb0aa9e58 (MD5) Previous issue date: 2008-03-31 / O objetivo deste estudo foi avaliar e comparar as propriedades mec?nicas selecionadas (resist?ncia ? tra??o diametral, microdureza Knoop) e conte?do de carga em peso pela an?lise termogravim?trica (TGA) de cinco marcas comerciais de resina composta diferentes em matriz org?nica e carga nas cores A2 esmalte e dentina: 4Seasons (4S), Ivoclar Vivadent; Esthet-X improved (EX), Dentsply; Filtek Supreme (SU), 3MESPE; Grandio (GR), Voco e Palfique Estelite (PE), Tokuyama Dental Corp. Para cada grupo, a resist?ncia ? tra??o diametral (n=10), a microdureza Knoop (n=10) e o conte?do de carga em peso pela an?lise termogravim?trica foram determinados. Os resultados obtidos nos ensaios foram comparados estatisticamente com an?lise de vari?ncia e Tukey (J = 0,05). As m?dias obtidas para resist?ncia ? tra??o diametral (MPa) foram: 4S dentina 36,08 b e 4S esmalte 39,26 ab ; EX dentina 44,44 ab e EX esmalte 45,12 ab ; GR dentina 45,23 ab e GR esmalte 49,24 a ; SU dentina 46,86 ab e SU esmalte 48,25 ab ; PE dentina 38,69 ab ; PE esmalte 38,58 ab (p < 0,05). As m?dias obtidas para microdureza Knoop (KHN) foram: 4S dentina 61,6b e 4S esmalte 57,98b; EX dentina 73,6b e EX esmalte 54,45b; GR dentina 123,90a e GR esmalte 74,89b ; SU dentina 101,30a e SU esmalte 123,10a ; PE dentina 55,89b ; PE esmalte 61,70b (p < 0,05). Para o conte?do de carga em peso (wt%): 4S dentina 75,84 e 4S esmalte 76,37; EX dentina 76,80 e EX esmalte 75,75 ; GR dentina 86,89 e GR esmalte 87,00 ; SU dentina 76,22 e SU esmalte 76,54 ; PE dentina 71,62; PE esmalte 70,56. Os comp?sitos testados n?o apresentaram comportamento mec?nico similar quanto ? resist?ncia ? tra??o diametral e microdureza Knoop. N?o foi observada diferen?a quando as pastas esmalte e dentina foram comparadas com exce??o da resina Grandio no teste de microdureza. A maior resist?ncia ? tra??o diametral foi observada para a Grandio esmalte enquanto a 4 Seasons dentina apresentou a mais baixa m?dia (p < 0,05). No teste de microdureza Knoop, a resina Filtek Supreme em ambas as pastas e a Grandio dentina apresentaram as maiores m?dias em compara??o aos demais grupos (p < 0,05).
70

Influ?ncia da largura do cinzel utilizado em ensaio mec?nico de cisalhamento sobre a resist?ncia da uni?o

Oliveira, Ant?nio Carlos Castellan de 05 August 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:20Z (GMT). No. of bitstreams: 1 406879.pdf: 817502 bytes, checksum: a388f3f8f4ce8e84782dbb5d5932a532 (MD5) Previous issue date: 2008-08-05 / O objetivo deste estudo foi comparar diferentes larguras de cinzel utilizadas em ensaios mec?nicos para avalia??o da resist?ncia de uni?o ao cisalhamento na interface esmalte dental / resina composta. Para a realiza??o do ensaio e cisalhamento, cinz?is com larguras de 0,5mm, 1,0 mm, 2,0 mm e 3,0 mm foram utilizados para testar 4 grupos (n=15). Foram utilizados 60 dentes bovinos do grupo incisivo que tiveram sua inclus?o, preparo de superf?cie e confec??o dos corpos de prova realizados de acordo com Goes (1994). As superf?cies de esmalte foram planificadas, condicionadas com ?cido fosf?rico (3M/ESPE) ? 15%, seguido da aplica??o do sistema adesivo Single Bond (3M) e de resina composta Z-250 (3M) conforme instru??es do fabricante. Para o ensaio de cisalhamento foi utilizada uma m?quina de ensaio universal EMIC DL 2000 (EMIC, BRASIL) a velocidade de 0,5mm/min. Os dados obtidos foram comparados estatisticamente com an?lise de vari?ncia e teste de Duncan com n?vel de signific?ncia de 5% (p < 0,05) e submetidos ao teste de correla??o de Pearson (p < 0,01). As m?dias obtidas em Megapascal para a resist?ncia de uni?o ao cisalhamento foram: 0,5mm - 19,66; 1,0mm 18,78; 2,0 mm 16,77; 3,0 mm 16,06. Houve diferen?a estatisticamente significativa entre os grupos, quando submetidos ? an?lise de vari?ncia (p = 0,045) e testes de compara??o m?ltipla de Duncan. A menor m?dia (MPa) foi registrada para o grupo com cinzel de 3,0mm (16,06), enquanto a maior m?dia (MPa) foi verificada para o grupo com cinzel de 0,5mm (19,66), que diferiram estatisticamente. A correla??o entre largura do cinzel e resist?ncia de uni?o foi significante (p < 0,01). Os resultados obtidos permitem concluir que os valores (MPa) de resist?ncia de uni?o ao cisalhamento sofrem influ?ncia da largura do cinzel utilizado no ensaio.

Page generated in 0.0257 seconds