• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 1
  • Tagged with
  • 98
  • 98
  • 98
  • 95
  • 95
  • 94
  • 77
  • 33
  • 32
  • 32
  • 28
  • 27
  • 22
  • 15
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avalia??o da adapta??o marginal ap?s apicectomia e selamento apical com laser Nd:YAG

Zerbinati, L?via Prates Soares 30 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:56Z (GMT). No. of bitstreams: 1 431773.pdf: 2376290 bytes, checksum: f2c60a6fa4a04eb80d3f349bc9b04f4d (MD5) Previous issue date: 2011-03-30 / As periapicopatias recidivantes s?o patologias de dif?cil resolu??o. Os novos m?todos e materiais, aplicados na cirurgia paraendod?ntica, t?m adicionado ?ndices de sucesso mais altos ? pr?tica odontol?gica. O objetivo deste trabalho foi avaliar as manobras de apicectomia associadas ? retrobtura??o com MTA e ao selamento apical com laser Nd:YAG (10Hz, 150mJ, 1,5W, 60s). Utilizou-se 40 dentes endodonticamente tratados e apicectomizados com broca diamantada em 90? com o longo eixo do dente. Foram formados, randomicamente, quatro grupos de amostras (n=10): (A apicectomia, B apicectomia e irradia??o laser Nd:YAG, C apicectomia+retrobtura??o com MTA, D apicectomia+retrobtura??o com MTA e irradia??o laser Nd:YAG). As amostras foram inclu?das em resina ep?xi e cortadas, primeiramente no sentido longitudinal, depois no sentido transversal. A an?lise por MEV demonstrou uma superf?cie apical mais homog?nea e sem canal?culos dentin?rios nos grupos B e D (p<0,01). Foram observadas fendas marginais, entre dentina e material obturador, em ordem decrescente de tamanho, desde o grupo B, grupo A, grupo D e grupo C (p<0,01). A an?lise por EDS indicou uma porcentagem maior de ?ons f?sforo e menor de c?lcio nos grupos irradiados com laser Nd:YAG. Em conclus?o, esta pesquisa demonstra o efeito positivo da aplica??o do laser Nd:YAG no selamento da superf?cie dentin?ria, apesar do efeito dimensional que causou na sua associa??o com o MTA.
42

Influ?ncia das t?cnicas de selamento dentin?rio imediato na deflex?o de c?spides, carga de fratura e microinfiltra??o de dentes restaurados com inlays em resina composta

Oliveira, Leandro Galvan de 30 March 2011 (has links)
Made available in DSpace on 2015-04-14T13:29:57Z (GMT). No. of bitstreams: 1 432037.pdf: 401361 bytes, checksum: f080ce3dd2c0d49690aab2a7f9731a56 (MD5) Previous issue date: 2011-03-30 / O objetivo do estudo foi avaliar, in vitro, a influ?ncia de duas t?cnicas de selamento dentin?rio imediato (SDI) na deflex?o de c?spides, carga de fratura e tipos de fratura de pr?-molares restaurados com inlays em resina composta. Quarenta e oito primeiros pr?-molares foram divididos aleatoriamente em quatro grupos (n=12): G1 (controle) - h?gidos; G2 sem SDI; G3 t?cnica do SDI com Clearfil SE Bond; G4 - t?cnica do SDI com Clearfil SE Bond e resina de baixa viscosidade Protect Liner F. Os dentes dos grupos 2, 3 e 4 receberam preparos m?sio-ocluso-distal. Os preparos foram moldados com silicone por adi??o, seguido de provis?rio e armazenamento em ?gua a 37? C por 7 dias. Os moldes foram vazados com gesso tipo IV e confeccionados inlays em resina composta Filtek Z250. As restaura??es foram cimentadas nos preparos com ED Primer A e B e cimento resinoso Panavia F. Ap?s armazenagem em ?gua destilada a 37? C por 24 horas, carga de 200 N foi aplicada na regi?o oclusal com uma esfera de 8 mm de di?metro acoplada na m?quina de ensaio universal EMIC DL 2000, sendo medida a deflex?o de c?spides com um micr?metro digital. Em seguida, os corpos de prova foram submetidos ao ensaio de compress?o at? a fratura na m?quina de ensaio universal. As m?dias de deflex?o de c?spides (&#956;m) e carga de fratura (N) seguida de mesma letra n?o t?m diferen?a estat?stica de acordo com ANOVA e teste de Tukey (p<0.05). Deflex?o de c?spide: G1=3,1 (?1.5)a, G2=10,3 (?4.6)b, G3=5,5 (?1.80)ac, G4=7,7 (?5.1)bc. Carga de fratura: G1=1974 (?708)a, G2=1162 (?474)b, G3=700 (?280)b, G4=810 (?343)b. A maioria das fraturas ocorridas nos grupos experimentais permite a recupera??o da estrutura dental. A t?cnica do SDI com Clearfil SE Bond proporcionou deflex?o de c?spides compar?vel ao dente h?gido. A aplica??o da resina de baixa viscosidade Protect Liner F sobre o Clearfil SE Bond n?o contribuiu para a redu??o da deflex?o de c?spides. As t?cnicas de SDI n?o foram capazes de restituir a resist?ncia do dente h?gido.
43

Expans?o r?pida maxilar com parafuso convencional e limitador posterior em pacientes com fissura transforame incisivo : altera??es verticais e ?ntero-posteriores

Lanes, Michel Azevedo 14 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:29:58Z (GMT). No. of bitstreams: 1 386491.pdf: 18791773 bytes, checksum: 23dd3e96c1894b6bf14e79ed56a61116 (MD5) Previous issue date: 2006-12-14 / O objetivo deste estudo foi avaliar e comparar os efeitos da expans?o r?pida maxilar (ERM) em pacientes com fissura de l?bio e palato, utilizando disjuntor de Haas modificado com dois diferentes tipos de parafusos expansores. A amostra constituiu-se de 31 indiv?duos portadores de fissura transforame incisivo com idade m?dia de 10,7 anos, que apresentavam atresia maxilar na regi?o anterior e rela??o transversal posterior correta. Destes, 17 pacientes foram submetidos a ERM com parafuso limitador posterior (Grupo LP) e 14 com parafuso convencional (Grupo C), sendo avaliadas telerradiografias de perfil no per?odo pr?expans?o (T1), p?s-expans?o (T2), e seis meses p?s-expans?o (T3). Atrav?s do teste t-student e teste de Friedman (p&#8804;0,05) verificou-se que em ambos os Grupos a maxila movimentou-se para baixo, no Grupo LP tamb?m para frente, no per?odo T2 e mantendo-se em T3. A movimenta??o mandibular foi semelhante entre os Grupos, havendo um posicionamento para baixo e para posterior em T2 retornando para anterior em T3. Os incisivos superiores nos Grupos LP e C extru?ram e no Grupo LP sofreram vestibulariza??o no per?odo de T2, mantendose em T3. Os molares superiores no Grupo Convencional sofreram extrus?o em T2 e retornaram a posi??o inicial em T3 e houve uma abertura do plano oclusal no Grupo Convencional, que foi reduzida em T3. Na avalia??o do perfil observou-se uma maior proje??o dos tecidos moles para anterior no Grupo LP.
44

Estudo in vivo da fidelidade de reprodu??o com moldeiras de dupla arcada

Lima, Luciana Martinelli Santayana de 13 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:29:59Z (GMT). No. of bitstreams: 1 386496.pdf: 391577 bytes, checksum: 23af4cf9ce3630d39442fc9f6ba06efb (MD5) Previous issue date: 2006-12-13 / Este estudo avaliou, in vivo, a fidelidade de reprodu??o das moldeiras de dupla arcada met?lica (Smart) e pl?stica (Triple Tray) com os materiais de impress?o silicone por adi??o (Flexitime), nas consist?ncias massa e leve, e o poli?ter (Impregum Soft) na consist?ncia regular. Em um paciente com implante na regi?o do dente 46 foi parafusado um transferente modificado, servindo este de padr?o. Foram realizadas dez impress?es com cada associa??o moldeira / material. Os moldes foram vazados com gesso tipo IV ap?s 1 hora. As medidas de largura e altura foram realizadas no padr?o e nos modelos, em um projetor de perfil (Nikon). Os resultados foram analisados pelo teste t-student para uma amostra (&#945;=0,05). Para a medida da largura, as moldeiras pl?sticas com silicone por adi??o (4,513 mm) e com poli?ter (4,531 mm), e a moldeira met?lica com poli?ter (4,500 mm) foram estatisticamente superiores ao padr?o (4,489 mm), sendo que a moldeira met?lica com silicone por adi??o (4,504 mm) n?o diferiu estatisticamente do padr?o. Para a altura, somente a moldeira met?lica com poli?ter (2,253 mm) diferiu estatisticamente do modelo mestre (2,310 mm). A moldeira de dupla arcada met?lica associada ao silicone por adi??o foi a que reproduziu modelos com menor distor??o.
45

Efeito do condicionamento de pinos de fibra de vidro na microdureza e morfologia superficial

Gon?alves, Jorge Alberto 31 August 2011 (has links)
Made available in DSpace on 2015-04-14T13:30:00Z (GMT). No. of bitstreams: 1 433335.pdf: 2918834 bytes, checksum: 4496c89629b05f14a110e33d393c80e6 (MD5) Previous issue date: 2011-08-31 / Artigo 1: O objetivo deste estudo foi verificar a influ?ncia do tratamento de superf?cie com per?xido de hidrog?nio (H2O2) a 10% e 24% e acetona p.a. sobre a microdureza superficial de pinos de fibra de vidro nos ter?os cervical, m?dio e apical. A morfologia de superf?cie dos pinos tratados com (H2O2) e acetona p.a., comparativamente ao pino sem nenhum tratamento de superf?cie foi avaliada qualitativamente, atrav?s de microscopia eletr?nica de varredura (MEV). Trinta e seis pinos de fibra de vidro (Exacto, ?ngelus, Londrina, PR, Brasil) foram embutidos em resina ep?xi (EMBed 812, Polysciences, Inc., Warrington, PA, USA) em cilindros de PVC (? = 20mm e h = 15mm), com seu longo eixo paralelo ? superf?cie; ap?s a polimeriza??o da resina, foram submetidos ao lixamento at? expor o di?metro maior do pino (lixas de carbeto de sil?cio 400, 600, 1200, e 4000 e disco de feltro em suspens?o diamantada 1,0 &#956;m). A seguir foram divididos, aleatoriamente, em quatro grupos (n= 9): grupo 1 - pinos sem tratamento de superf?cie (grupo controle); grupo 2 pinos condicionados com H2O2 ? 10 % por 1 minuto; grupo 3 - pinos condicionados com H2O2 ? 24% por 1 minuto; grupo 4 - pinos condicionados com acetona p.a. por 1 minuto. Em seguida, todos os grupos foram submetidos ao teste de microdrureza Vickers em tr?s diferentes ter?os do pino (coron?rio, m?dio e apical) com carga de 1g por 5s. Cada corpo-de-prova recebeu tr?s indenta??es (uma em cada ter?o) no microdur?metro (Shimadzu HMV tester, Shimadzu, Kioto, Japan). Os resultados foram analisados estatisticamente utilizando o teste ANOVA com dois fatores fixos e Tukey com &#945; = 0.05, que indicou que o grupo controle apresentou m?dia de VHN de 1.86 (? 0.46), superior ao grupo 2 (0.72 ? 0.18), grupo 3 (0.57 ? 0.09) e ao grupo 4 (0.51 ? 0.09). O grupo controle apresentou a maior m?dia para microdureza no ter?o apical superior ?s demais intera??es, que foram semelhantes entre si. As imagens da MEV de corpos-de-prova dos diferentes grupos demonstraram que os tratamentos de superf?cie ensaiados alteram a morfologia da superf?cie, removendo parcialmente a resina ep?xi dos pinos, expondo as fibras de vidro e indicando sua eros?o/desgaste parcial. Artigo 2: O objetivo deste estudo foi verificar a influ?ncia do tratamento de superf?cie com per?xido de hidrog?nio (H2O2) a 10%, per?xido de hidrog?nio(H2O2) a 24%, ?xido de alum?nio (Al2O3) a 50&#956;m e acetona p.a. sobre a rugosidade (Ra) superficial de pinos de fibra de vidro nos ter?os coron?rios, m?dio e apical. A morfologia de superf?cie dos pinos tratados com per?xido de hidrog?nio e acetona p.a., comparativamente ao pino sem nenhum tratamento de superf?cie foi avaliada qualitativamente, atrav?s de microscopia eletr?nica de varredura (MEV). Quarenta e cinco pinos de fibra de vidro (Exacto, ?ngelus, Londrina, PR, Brasil) foram embutidos em resina ep?xi (EMBed 812, Polysciences, Inc., Warrington, PA, USA) em cilindros de PVC (?= 20 mm e h=15mm), com seu longo eixo paralelo ? superf?cie; ap?s a polimeriza??o da resina, foram submetidos ao lixamento at? expor o di?metro maior do pino (lixas de carbeto de sil?cio 400, 600, 1200 e 4000 e disco de feltro em suspens?o diamantada 1.0 &#956;m). A seguir foram divididos, aleatoriamente, em cinco grupos (n= 9): grupo1 - pinos sem tratamento de superf?cie (grupo controle); grupo 2 pinos condicionados com H2O2 ? 10 % por 1 minuto; grupo 3 - pinos condicionados com H2O2 a 24% por 1 minuto; grupo 4 pinos condicionados com Al2O3 (50&#956;m) e grupo 5 - pinos condicionados com acetona p.a. por 1minuto. Em seguida, a superf?cie de todos os corpo-de-prova foi analisada no rugos?metro SJ 201 (Mitutoyo surftest analyser, Kanagawa, Japan), a partir de tr?s leituras em cada uma das tr?s regi?es do pino (ter?os coron?rio, m?dio e apical). Os resultados foram analisados estatisticamente utilizando o teste ANOVA com dois fatores fixos e Tukey com &#945;=0.05 atrav?s de um programa de computador SPSS, indicou que o grupo 5 apresentou m?dia de rugosidade superficial (Ra, DP) 0.59 (? 0.05), superior ao grupo controle (0.15 ? 0.05), grupo 2 (0.18 ? 0.05) e grupo 3 (0.20 ? 0.03) e grupo 5 (0.26 ? 0.04). N?o foi detectada diferen?a de rugosidade superficial entre as regi?es apical, m?dia e cervical dos pinos de fibra de vidro. As imagens de MEV dos corpos-de-prova dos diferentes grupos demonstraram que os tratamentos de superf?cie ensaiados alteram a morfologia da superf?cie, removendo parcialmente a resina ep?xi dos pinos, expondo as fibras de vidro e indicando altera??o estrutural parcial.
46

An?lise local e sist?mica das rea??es tissulares a diferentes materiais utilizados em pulpotomias : estudo em ratos

Follmann, Carina Staudt 31 August 2011 (has links)
Made available in DSpace on 2015-04-14T13:30:02Z (GMT). No. of bitstreams: 1 434141.pdf: 4096445 bytes, checksum: 46ea01752aceb50c79baf98a79715628 (MD5) Previous issue date: 2011-08-31 / Introdu??o : O objetivo deste estudo foi avaliar, em ratos, a rea??o do tecido conjuntivo subcut?neo, e dos ?rg?os f?gado e rim, a materiais utilizados em pulpotomias: agregado tri?xido mineral (MTA), pasta de hidr?xido de c?lcio (HC) e formocresol (FC). M?todos: Tubos de polietileno vazios (grupo controle) e contendo os materiais de teste foram implantados no tecido subcut?neo de 46 ratos. Ap?s 7 e 21 dias, as observa??es no dorso foram feitas para altera??es inflamat?rias, condensa??o fibrosa, forma??o de abscesso e corpo estranho e, no f?gado e rim, foram avaliadas esteatose, apoptose, inflama??o, altera??es vasculares e hipercelularidade. Compara??es entre os grupos e per?odos de tempo foram feitas usando o teste de Kruskal-Wallis, Post-hoc e Mann-Whitney. Resultados: Os grupos MTA e HC mostraram um comportamento semelhante ao do grupo controle, nas altera??es inflamat?rias em 21 dias, ao contr?rio do grupo FC, o qual apresentou diferen?a estatisticamente significante em rela??o aos outros grupos. No grupo FC, n?o houve forma??o de c?psula fribrosa e houve forma??o de abscesso, em 21 dias. Em todos grupos, altera??es no f?gado e rim foram observadas. Conclus?o: Os grupos MTA e HC mostraram um comportamento similar em todos os eventos analisados. O grupo FC apresentou resultados n?o favor?veis. Foram observadas altera??es tissulares no f?gado e rim.
47

Compara??o da rugosidade ap?s abras?o por escova??o e da microdureza entre resinas compostas nanoparticuladas e microh?brida

Rosa, Rog?rio Sim?es 11 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:02Z (GMT). No. of bitstreams: 1 386619.pdf: 4143713 bytes, checksum: 264c046972f7bb6da411606f1d2ba903 (MD5) Previous issue date: 2006-12-11 / O objetivo deste estudo in vitro foi avaliar a rugosidade ap?s abras?o por escova??o de corpo triplo e a microdureza Vickers de resinas compostas para uso direto com diferentes tamanhos de part?culas de carga inorg?nica, como a microh?brida Z250 e as nanoparticuladas Z350 e Supreme XT, de mesma marca comercial (3M ESPE, St Paul, Minessota, EUA). Seis corpos-de-prova (n=6) foram confeccionados para cada resina composta (Supreme XT, Z250 e Z350) e submetidos, na seq??ncia, a cada per?odo simulado de escova??o (controle, 6 meses, 1 ano e 2 anos). Foram realizadas 3 leituras de rugosidade de superf?cie Ra (&#956;m) em cada amostra ap?s cada simula??o (total=216). Foi confeccionado 1 corpode- prova representativo de cada per?odo simulado de escova??o para cada resina composta (total=12), a fim de que fosse observado em MEV. Os valores m?dios m?nimos e m?ximos obtidos foram, respectivamente, de 0,14 &#956;m (controle) para a resina Z350 e 0,21 &#956;m (1 ano) para a resina Z250. Foi aplicada a an?lise de vari?ncia, seguida do teste de Tukey ( =0,05) e constatou-se que n?o houve diferen?a estatisticamente significante entre os grupos. A fim de avaliar a rugosidade em rela??o ao tempo e ao tipo de resina composta testada foi aplicado o modelo linear geral, seguido do teste de Tukey ( =0,05). Observou-se uma diferen?a estatisticamente significante da rugosidade no per?odo controle (0,15 &#956;m) em rela??o ao per?odo de 1 ano (0,19 &#956;m), com rela??o ao tipo de resina, ambas nanoparticuladas (0,16 &#956;m) apresentaram-se significativamente menos rugosas que a microh?brida (0,19 &#956;m). Os aspectos morfol?gicos superficiais obtidos em MEV mostram que houve padr?es semelhantes de desgaste entre as resinas compostas nos grupos controle. Ap?s os per?odos simulados de escova??o de 6 meses, 1 ano e 2 anos, observou-se uma surperf?cie mais uniforme para as resinas compostas nanoparticuladas em rela??o ? microh?brida. Para a microdureza Vickers, 5 amostras para cada resina composta foram confeccionadas (n=5). As m?dias (VHN) foram: Z250 74,44; Z350 73,87; XT 78,28. Ap?s an?lise de vari?ncia, observou-se que n?o houve diferen?a significante entre elas. Baseado nos resultados, concluiu-se que as resinas compostas nanoparticuladas (Z350, Supreme XT) obtiveram comportamento similar ? microh?brida (Z250) quanto ? microdureza Vickers, por?m, se apresentaram menos rugosas ap?s a abras?o por escova??o.
48

Avalia??o in vitro da citotoxicidade celular do cimento de ion?mero de vidro modificado por carbonato de c?lcio de conchas marinhas

Giacomelli, ?dio 12 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:08Z (GMT). No. of bitstreams: 1 437942.pdf: 14499337 bytes, checksum: 95040a95e0a346b6d9760a8fda191ce6 (MD5) Previous issue date: 2012-03-12 / This study aimed to evaluate the cytotoxicity and bioactivity of the glass ionomer cement modified with calcium carbonate shells. For testing cell toxicity was using Saccharomyces cerevisiae as a model organism. The induction of cytotoxicity was evaluated by two different tests using wild-type strain FF18733 of S. cerevisiae: (1) yeast cell survival and (2) formation of petite colonies (respiratory mutants). For tests of bioactivity was evaluated weight change of samples and analysis of hydroxyapatite deposition by SEM and EDS after immersion in simulated blood plasma. The results of survival tests showed that different concentrations of calcium carbonate added to the GIC (1%, 5% and 10% by weight) induced a slight loss of cell viability in S. cerevisiae in relation to the negative control, but it was not enough to be considered as a significant induction of toxicity. In relation to the petite colonies, there was no induction of mutants respiratory formation in any of the concentrations tested, indicating that the GIC did not induce altered oxidative stress in cells of S. cerevisiae. In the evaluation of bioactivity, the results showed that after immersion all groups tested showed a decrease in weight of the samples, which can be attributed to the dissolution of glass ionomer cement. In the fourth week of immersion there was a significant variation in the average percentage of weight for all groups. The SEM analysis showed a slight deposition of hydroxyapatite on the surface of the groups with the addition of powdered shells compared to the control group. / Este estudo teve como objetivo avaliar a citotoxicidade e bioatividade do cimento de ion?mero de vidro modificado com carbonato de c?lcio de conchas. Para os testes de toxicidade celular foi utilizando a Saccharomyces cerevisiae como organismo modelo. A indu??o de citotoxicidade foi avaliada por dois testes diferentes usando a S. Cerevisiae cepa selvagem wild-type FF18733: (1) a sobreviv?ncia da c?lula de levedura e (2) forma??o de col?nias petite (mutantes respirat?rios). Para os testes de bioatividade foi avaliada a varia??o de peso das amostras e an?lise de deposi??o de hidroxiapatita pela MEV e EDS ap?s imers?o em solu??o simuladora de plasma sang??neo. Os resultados dos testes de sobreviv?ncia mostraram que as diferentes concentra??es de carbonato de c?lcio adicionado ao CIV (1%, 5% e 10% em peso) induziram uma ligeira perda de viabilidade celular em S. cerevisiae em rela??o ao controle negativo, por?m n?o foi o suficiente para ser considerado como uma indu??o de toxicidade significativa. Em rela??o ?s col?nias petite, n?o foi observada a indu??o de forma??o de mutantes respirat?rios em qualquer uma das concentra??es testadas, indicando que o CIV modificado n?o induziu estresse oxidativo em c?lulas de S. cerevisiae. Na avalia??o da bioatividade, os resultados mostraram que ap?s a imers?o todos os grupos testados apresentaram uma diminui??o no peso das amostras, que pode ser atribu?do ? dissolu??o do cimento de ion?mero de vidro. Na quarta semana de imers?o houve uma varia??o significativa na percentual m?dio de peso para todos os grupos. A an?lise de MEV mostrou uma ligeira deposi??o de hidroxiapatita sobre a superf?cie dos grupos com a adi??o de p? de conchas em compara??o ao grupo controle.
49

Compara??o da distribui??o de tens?es em dois tipos de conex?o prot?tica de implantes com parafusos diferentes utilizando o m?todo de an?lise por elementos finitos com modelo tridimensional

Herbstrith Segundo, Reg?nio Mahfuz 12 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:17Z (GMT). No. of bitstreams: 1 388162.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5) Previous issue date: 2006-12-12 / O objetivo deste estudo foi avaliar e comparar qualitativamente, atrav?s de an?lise por elementos finitos com modelo 3D, a distribui??o das tens?es geradas por cargas simuladas sob modelos de implantes, pilares, coroas prot?ticas metalocer?micas na regi?o de primeiros molares. As an?lises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 2 com encaixe prot?tico tipo hex?gono externo e parafuso de pilar de ouro e tit?nio respectivamente, modelo 3 e modelo 4 com encaixe tipo hex?gono interno e parafuso de pilar de ouro e tit?nio respectivamente, a carga aplicada foi padronizada em 382N com duas angula??es diferentes, inclina??es de 90? com a superf?cie oclusal e de 15? em rela??o ao longo eixo dos implantes, em dois pontos distintos, 4 e 6 mm do centro do implante, em 10 pontos diferentes de observa??o no conjunto implante-pilar-parafuso. Os resultados obtidos sugeriram que de uma maneira geral, os modelos com encaixe interno (3 e 4) possuem um melhor comportamento mec?nico em rela??o a distribui??o de tens?es ao longo do complexo implante-pilar-parafuso. Nos modelos 1 e 2 o tipo de material que o parafuso de pilar ? feito influencia na distribui??o de tens?es, por outro lado, nos modelos 3 e 4 isto n?o foi observado
50

Efici?ncia de corte de instrumentos rotat?rios de n?quel-tit?nio para alargamento cervical de canais radiculares : an?lise em estereomicroscopia, perfilometria e microtomografia computadorizada

Morgental, Renata Dornelles 07 November 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:18Z (GMT). No. of bitstreams: 1 444223.pdf: 7075899 bytes, checksum: e2b966a0c07482d14bfbf7d107754d2e (MD5) Previous issue date: 2012-11-07 / This study aimed to: evaluate, using different methods and substrates, the cutting efficiency of nickel-titanium rotary instruments for coronal flaring; investigate the influence of rotational speed and number of uses on the cutting efficiency of such instruments; observe the presence of surface defects. First, bovine dentin blocks (n=20) and acrylic blocks (n=20) were made, as substrate for evaluating the performance of the following instruments: BR0 BioRaCe (BR), HyFlex CM 1 (HY), ProFile OS #2 (PF) and ProTaper Sx (PT). Each instrument worked sideward for 60 seconds, mounted on a testing platform. The instruments were used at two rotational speeds (250 and 500 rpm) up to 5 times. On the first stage, those blocks were observed under a stereomicroscope and the notches created by the instruments were measured.Area and length were used as parameters to assess cutting efficiency. Data were statistically analyzed with significance level set at 5%. HY and PF were the most and least efficient instruments (P<0.05), respectively. Against acrylic, with greater speed, significant increase in area and length was observed for all instruments. Against dentin, there was significant increase in area for HY and PT and in length for BR, HY and PT. Regarding the number of uses, there was no cutting efficiency loss against acrylic. On dentin, however, PF and PT instruments were significantly less efficient after the fourth and fifth use (shorter length). Strong correlation was found between the results on acrylic and dentin for all brands. On the second stage, two new parameters were used to assess cutting efficiency.Dentin blocks were evaluated under a profilometer to determine the maximum cutting depth of the notches. Half of them were also investigated by microcomputed tomography (micro-CT) to check the volume of extracted dentin. Data were statistically analyzed with significance level set at 5%. Again, HY and PF were the most and least efficient instruments (P<0.05). Speed increase significantly improved maximum cutting depth (BR, HY and PT) and volume of extracted dentin (HY and PF). BR and PT instruments lost their cutting efficiency after repeated use (depth and volume) as well as HY (volume).Positive correlation coefficients were found between profilometry and micro-CT results. Finally, instruments were examined under scanning electron microscopy (SEM) for the presence of surface defects. Most instruments had blunt cutting edges after use, but there was no relevant deformation or fracture. In conclusion, stereomicroscopy showed similar results to wellrecognized methods (profilometry and micro-CT), evidencing HY superiority. Rotational speed and number of uses had a positive and negative influence, respectively, on the cutting efficiency of nickel-titanium coronal flaring instruments / Os objetivos deste estudo foram: avaliar, utilizando diferentes metodologias e substratos, a efici?ncia de corte de instrumentos rotat?rios de n?quel-tit?nio para alargamento cervical; investigar a influ?ncia da velocidade e do n?mero de usos na efici?ncia de corte de tais instrumentos; observar a presen?a de defeitos na superf?cie dos mesmos. Primeiramente, foram confeccionados blocos de dentina bovina (n=20) e de acr?lico (n=20), os quais serviram de substrato para a atua??o dos seguintes instrumentos: BioRaCe BR0 (BR), HyFlex CM 1 (HY), ProFile OS #2 (PF) e ProTaper Sx (PT). Cada instrumento atuou por 60 segundos lateralmente aos blocos, montados em uma plataforma de testes. Os instrumentos foram utilizados em duas velocidades (250 e 500 rpm), at? cinco vezes. Em um primeiro momento, os blocos foram observados em um estereomicrosc?pio e as medidas de ?rea e comprimento dos sulcos formados pelos instrumentos foram utilizadas como par?metro para avaliar a efici?ncia de corte.Os dados obtidos foram analisados estatisticamente, com n?vel de signific?ncia de 5%. HY e PF foram os instrumentos mais e menos eficientes (P<0.05), respectivamente. Em acr?lico, com o aumento da velocidade, houve aumento significativo da ?rea e do comprimento dos sulcos para todos os instrumentos. Em dentina, houve aumento significativo da ?rea para HY e PT e do comprimento para BR, HY e PT. Com rela??o ao n?mero de usos, n?o houve perda de efici?ncia de corte em acr?lico. J? em dentina, os instrumentos PF e PT apresentaram efici?ncia significativamente menor ap?s o quarto e quinto uso (menor comprimento dos sulcos). Para todos os instrumentos, foi detectada forte correla??o entre os resultados em acr?lico e dentina. Em um segundo momento, outros dois par?metros foram utilizados para determinar a efici?ncia de corte.Os blocos de dentina foram avaliados em um perfil?metro, para determina??o da profundidade m?xima de corte dos sulcos gerados e metade deles tamb?m foi investigada em microtomografia computadorizada, para verifica??o do volume de dentina extra?da. Os dados foram analisados estatisticamente, com n?vel de signific?ncia de 5%. Novamente, HY e PF foram os instrumentos mais e menos eficientes (P<0.05). O aumento da velocidade proporcionou aumento significativo da profundidade de corte (BR, HY e PT) e do volume de dentina extra?da (HY e PF). Os instrumentos BR e PT perderam a efici?ncia de corte ap?s uso repetido (profundidade de corte e volume), assim como o HY (volume).Foi detectada correla??o positiva entre os resultados do perfil?metro e microtom?grafo. Por fim, parte dos instrumentos foi examinada em microscopia eletr?nica de varredura (MEV), quanto ? presen?a de defeitos de superf?cie. A maioria deles apresentou bordos de corte arredondados ap?s o uso, por?m n?o foi observada deforma??o relevante ou fratura. Pode-se concluir que a estereomicroscopia apresentou resultados semelhantes aos m?todos consagrados (perfilometria e microtomografia), mostrando a superioridade do instrumento HY. Os aumentos da velocidade e do n?mero de usos influenciaram positiva e negativamente, respectivamente, a efici?ncia de corte dos instrumentos de n?quel-tit?nio para alargamento cervical

Page generated in 0.0232 seconds