• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 9
  • 8
  • 4
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 122
  • 122
  • 37
  • 29
  • 18
  • 18
  • 17
  • 17
  • 16
  • 15
  • 15
  • 15
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Vývoj instrumentace a metod s vysokou propustností pro hledání a validaci peptidových ligandů / Development of instrumentation and high-throughput screening methods for peptide ligand discovery and validation

Kryštůfek, Robin January 2021 (has links)
Peptides are used as synthetically available and easily derivatizable scaffold upon which it is possible to develop ligands targeting broad spectrum of biological targets. A time-tested approach to peptide binder identification is the preparation and screening of combinatorial libraries. Bypassing of this complicated procedure is possible by using biological systems for presentation, identification and selection of peptides based on the principle of in vitro evolution - i.e. display techniques. There are two complementary automated solutions for peptide binder identification described in this work. First is the SPENSER parallel peptide synthesizer, developed as a part of this diploma project, which can be used for peptide ligand discovery and optimization as well as validation of ligands identified using display techniques. Several libraries consisting of a total of 1 052 peptides have been prepared and then used to describe its potential applications. A sample of 154 preparations, representing 14.6 % analytical coverage of the prepared libraries, showed an average purity of 67 ± 19 % according to LC-MS. The libraries presented illustrate that SPENSER is a suitable tool for the parallel synthesis of linear and disulfide-cyclized peptides with limited variability, or libraries consisting of short...
92

Caractérisation des solvants régénérables utilisés pour la capture du CO2 par chromatographie liquide couplée à la spectrométrie de masse

Gallant, Stéphanie 12 1900 (has links)
No description available.
93

Development of verified FE simulation method on crimp joint with gasket : A combined experimental and numerical study

Andraéy, Erik January 2021 (has links)
When developing drivetrain cooling modules for commercial vehicles, the top priority is the strength of the products. The reason lays within the structural change that companies are undergoing where the warehouses are minimized and the companies are relying on the transportation of commercial vehicles. If a drivetrain cooling module would fail to maintain a targeted temperature range of the drivetrain, there is not long until the vehicle is forced to a stop. At worst, the downtime of commercial vehicles can cause companies to come to a halt as well. Therefore, developing verified FE simulation methods together with strength verification tests, are some of the core activities to ensure the strength of the cooling modules before implementation in vehicles. One of the methods that have not been sufficiently verified regards how to perform structural FEA on a crimp joint with a gasket. A crimp joint is established through a hemming process, where the aluminium header tabs are crimped over the polyamide tank, creating a watertight seal together with a gasket. The objective of this master’s thesis is to verify the existing simulation methods of the crimp joint and determine the margin of error with respect to strains. The objective of this thesis is also to develop a verified FE simulation method with a lower margin of error compared to the existing methods. The verification of the methods has been conducted through a comparison between numerical results and an experimental stress analysis, where the strain located on the header is measured with strain gauges in a pressure pulsation rig. The average margin of error found on the three existing methods of simulating the crimp joint was 39,7%, 13,4%, and 11,5% located on the outer bottom dimensioning radius of the crimp joint at a pressure of 100 kPa. However, the method used to determine the margin of error was found to be invalid, but the margin of error is only slightly affected by the verification method where the existing methods still are insufficiently representing the crimp joint. The method of determining the margin of error was then corrected for the development of the new method to represent the crimp joint in the FE model. The developed method in this thesis has an average margin of error of 6,9% at 100, 160, 220, and 260 kPa. / Vid utveckling av kylarmoduler för drivlinor som appliceras i kommersiella fordon, är högsta prioritet att säkerhetsställa hållfastheten hos produkterna. Anledningen ligger kring den strukturomvandling som företag genomgår där storleken på lagerlokaler minskar och företagen väljer att förlita sig på transporterna som utförs av kommersiella fordon istället. Ifall en kylarmodul inte skulle klara av att bibehålla ett bestämt temperaturintervall hos drivlinan så dröjer det inte länge förens fordonet tvingas att stanna. I värsta fall kan fordonets stillestånd påverka ett företag att tvingas stanna i väntan. Därför är utveckling av FE simuleringsmetoder tillsammans med utmattningstest, några av de kärnaktiviteter som utförs för att säkerhetsställa hållfastheten av kylarmodulerna innan de implementeras i fordon. En av de metoder som ännu inte blivit tillräckligt verifierat gäller hur man utför FEA på ett falsförband med packning. Falsförbandet skapas genom en falsningsprocess där ändplåten av aluminium falsas över polyamidtanken, vilket skapar ett vattentätt förband med hjälp av packningen. Omfattningen av detta examensarbete gäller att verifiera de existerande simuleringsmetoderna av falsförbandet och bestämma felmarginalen med avseende på töjningar. Omfattningen av examensarbetet innefattar även ett utvecklingsarbete av en ny FE simuleringsmetod med en lägre felmarginal jämfört med de existerande metoderna. Verifieringen av metoderna sker genom en jämförelse mellan de numeriska resultaten och en experimentell spänningsanalys där töjningen på ändplåten är uppmätt med hjälp av trådtöjningsgivare i en tryckpulsationsrigg. Den genomsnittliga felmarginalen av de tre existerande metoderna för att simulera falsförbandet var 37,9%, 13,4%, och 11,5% vid den nedre dimensionerande yttre radien på falsförbandet vid ett tryck på 100 kPa. Den använda metoden för att bestämma felmarginalen upptäcktes senare vara felaktig, men det resulterar endast i små förändringar av den bestämda felmarginalen, de existerande simuleringsmetoderna är fortfarande sedda som otillräckliga. Metoden för att bestämma felmarginalen korrigerades sedan inför utvecklandet av den nya FE simuleringsmetoden av falsförbandet. Den utvecklade metoden i detta examensarbete har en genomsnittlig felmarginal på 6,9% vid 100, 160, 220 och 260 kPa.
94

Development of headspace solid phase microextraction gas chromatography mass spectrometry method for analysis of volatile organic compounds in board samples : Correlation study between chromatographic data and flavor properties / Utveckling av fastfas mikroextraktion gaskromatografi masspektrometisk metod för analys av flyktiga organiska föreningar i kartongprover : Korrelationsstudie av kromatografisk data och smakegenskaper

Zethelius, Thea January 2021 (has links)
The purpose of this thesis work was to develop a headspace solid phase microextraction gas chromatography mass spectrometry (HS-SPME-GC-MS) method to detect volatile organic compounds (VOCs) in board samples and to statistically investigate potential correlation between chromatographic data and flavor data obtained from a trained panel. The developed method would hopefully serve as a complement to the already established routine analyses at Stora Enso and gain an increased understanding of which VOCs in the board influence its flavor properties. The impact of incubation time and adsorption time on the area under curve (AUC) was studied with a Design of Experiment screening using the software MODDE. The screening data showed a correlation between large AUC and low repeatability measured as relative standard deviation (RSD). The data was hard to fit to a model due to the large RSD values for the replicates, AUC for identified compounds as response gave an acceptable fit. The regression coefficients for the model showed that a longer adsorption time gave larger AUC, while incubation time had no significant impact on the response.  Instead of following up the screening with an optimization, the focus was shifted to improving the repeatability of the method, i.e. lowering the RSD. The high RSD was believed to mainly be the result of leakage of analytes and unstable temperature during adsorption, preventing the system from reaching equilibrium. Different heating options and capping options for the vial was tested. Septum in crimp cap ensured a gas tight seal for the vial, giving lower RSD values and larger AUC compared to the other alternatives, showing that there was indeed a leakage. Using oil bath ensured stable temperature during the adsorption and detection of a larger number of VOCs but created a temperature gradient in the vial due to it not being fully submerged in the oil. Oil bath gave larger AUC, but still high RSD due to the temperature gradient making the method sensitive to variance in fiber depth in the vial. The final method was performed with 2 g of board sample in a 20 ml headspace vial sealed with a crimp cap with septa. The incubation and adsorption were performed with the vial immersed in a 90-degree oil bath. 20 min incubation time was chosen based on the time it took to get a stable temperature gradient in the vial, and 20 minutes adsorption time was chosen as a good compromise between large AUC and low RSD. Compared to Stora Ensos routine analysis, the developed SPME method gave chromatograms with an improved signal-to-noise ratio for the base line and several more peaks with larger AUC. For the board sample used during method development, the SPME-method identified 34 VOCs, while the routine analysis only identified 12. The developed method was applied on 11 archived board samples of the same quality that were selected based on their original flavor properties, to get a large diversity of samples. Flavor analysis was performed by letting a trained flavor panel describe the flavor based on intensity and character of the water that had individually been in indirect contact with one of the 11 board sample for 24 h. Potential correlation between chromatographic data obtained with the developed method and the flavor experience described by the flavor panelists was statistically investigated with the multivariate analysis software SIMCA. The correlation study showed that a combination of 12 VOCs with short retention time are most likely the main source of off-flavor which of 5 could only be identified with the developed SPME method. VOCs with long retention time did not contribute to an off-flavor and might have a masking effect on flavor given by other VOCS, however not confirmed in this study. Furthermore, the age of the board samples proved to be a good indicator for prediction of the flavor intensity, whereas the total AUC of the samples was not. Possible correlation between detected VOCs in the samples and flavor character given by the flavor panel were seen, however the variation in the data and the sample set were too small, preventing from making conclusions on individual VOCs impact on the flavor experience. The developed HS-SPME-GC-MS method would serve as a complement to the already established routine analyses at Stora Enso and has slightly increased the understanding of which VOCs in the board influence the flavor properties
95

Part I: The role of RNase L in lipid homeostasis and the development of atherosclerosisPart II: The role of RNase L in lipopolysaccharide-induced lung inflammationPart III: Development of LC-MS/MS assay for GSK3 inhibitors in plasma

Wei, Ruhan January 2019 (has links)
No description available.
96

Method Development for Analysis of Antioxidants for Use in Areas Sensitive to Discoloration and of High Molecular Weight UV-Stabilizers / Metodutveckling för Analys av Antioxidanter som Används i Områden Känsliga för Färgändring och av UV-Stabilisatorer med Hög Molekylvikt

Camaj, David January 2022 (has links)
Vanliga fenoliska antioxidanter som används i polymerer orsakar färgändringar i polymeren. Detta arbete berör antioxidanter med jämförelsevis begränsad färgändring, med fokus på att utveckla metoder för analys av dessa. UV-stabilisatorerna UV2, UV5, UV1, UV4, UV3 och UV6 är också inkluderade i detta arbete. Metodutvecklingen involverade både kapillärelektrofores och ”matrix assisted laser desorption ionization-time of flight mass spectrometry” (MALDI-TOF). Den bästa metoden för analys av de flesta av additiven inkluderade MALDI-TOF med 2’,6’-dihydroxyacetophenon (10 mg/ml) i TA50 som matris och hexafluoroisopropanol som lösningsmedel. När en metod för detektion av analyterna hade tagits fram, så inleddes utveckling av en metod för extraktion av additiv från polymera material. Extraktion av UV5 var framgångsrik vid användning av toluen vid 80 °C i ultraljudsbad i tre timmar. Det extraherade UV5 detekterades sedan med metoden som hade utvecklats för det rena additivet. / Ordinary phenolic antioxidants used in polymers give rise to color formations. This work concerns antioxidants with limited color-formations in comparison, with the focus being development of methods for analysis of these. Also included in this work are the high molecular weight UV-stabilizers UV2, UV5, UV1, UV4, UV3 and UV6. The method development involved both capillary electrophoresis and matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF). The best method for analysis of most additives involved using MALDI-TOF with a matrix consisting of 2’,6’-dihydroxyacetophenone (10 mg/ml) in TA50 and with hexafluoro isopropanol as the solvent. When a method for detection of the analytes had been obtained, a method for extraction of the additives from polymers was developed. UV5 was successfully extracted using toluene as the extracting solvent at 80 °C under sonication for three hours. The extracted UV5 was then detected using the method developed for the pure additive.
97

Analysis of organic compounds in the rhizosphere soil of Cyperus rotundus using LC-MS / Analys av organiska föreningar i rhizosfärsjord från Cyperus rotundus med LC-MS

Ruotsalainen, Daniel January 2018 (has links)
Den presenterade studien hade som syfte att utveckla en extraktions-, provpreparerings- och analysmetod för jorden, i vilken gräset Cyperus rotundus växer, i ett försök att identifiera möjliga äggläggningsattraherande ämnen för myggan Anopheles gambiae. Högupplösande vätskekromatografi med hydrofob stationär fas (RP-HPLC, en.) med Masspektrometri med Elektrosprejjonisering (ESI-MS, en.) användes för separation och detektion av de extraherade proverna. Ett flertal extraktionssatser gjordes, där parametrar och tekniker ändrades under utvecklingen av arbetet. Ultraljudsassisterad extraktion (UAE) av jord i en 50:50 (v/v) blandning av metanol och vatten visades vara mest effektiv av de undersökta metoderna. Upprening av jordextraktioner med fastfasextraktion (SPE, en.) visades ha en positiv inverkan på signalintensiteten i kromatogrammen såväl som att reducera intensiteten av de systemtoppar som eluerar vid dödtiden. Detta indikerar att de poläraste ämnena har renats bort. En jämförelse gjordes mellan en extraktion av jord som legat i blöt i fem dagar och jord som extraherats utan att blötläggas. En skillnad kunde ses och visades genom att jämföra kromatogram och masspektra från de två proverna. Tandem-MS-experiment gjordes för ett flertal prekursorjoner med avsikt att identifiera ämnena genom jämförelse med databaserna Human Metabolome Database (HMDB), Metlin och Massbank, men inga överrensstämmande jämförelser kunde göras. Tandem-MS-resultaten användes även för att jämföra efter varandra följande kromatografiska toppar med liknande MS1-spektrum. En identifieringsmetod bör utvecklas innan metoden som presenterats i detta arbete valideras och vidareutvecklas. / The present study aimed to develop an extraction, sample preparation and analysis method for the rhizosphere soil of the grass Cyperus rotundus in an attempt to identify possible oviposition attractants of the Anopheles gambiae mosquito. Reversed Phase High Performance Liquid Chromatography (RP-HPLC) coupled online with Electrospray Ionization Mass spectrometry (ESI-MS) was used for the separation and detection of the extracted samples. Multiple extraction batches were done, altering parameters and techniques along the way. Ultrasound-Assisted Extraction (UAE) of the soil with a 50:50 (v/v) mixture of methanol and water was determined to be the most effective of the attempted methods. Purifying soil extracts with Solid Phase Extraction (SPE) showed to have an impact on the signal intensities in the chromatogram as well as reducing the intensity of system peaks eluting at the dead-time. This indicates that more polar compounds were removed during the SPE purification. A comparison was done between an extraction of soil soaked in water for five days and soil extracted without prior wetting. A difference could be seen and was shown by comparing chromatograms and mass spectra from the two samples. Tandem MS experiments were done for multiple precursor ions in order to identify the compounds by comparison in databases Human Metabolome Database (HMDB), Metlin and Massbank, but no matches in the databases were found. The tandem MS results were also used for comparison of consecutive chromatographic peaks with similar MS1-spectra. An identification method should be developed before the method presented in this work is validated and optimized further.
98

Method Development & Analysis of Seals using FEM / Metodutveckling och analys av tätningar med FEM

Svanborg Östlin, Lovisa January 2023 (has links)
Hyperelasticity is a significant property of rubber, taken advantage of in engineering applications. A common application is the use of seals to prevent fluid transfer (liquid or gas) between solid regions. Volvo CE is often depending on external supplier when developing seals. However, it could be beneficial to be able to do design and analysis in-house. Thus, they want with this master thesis to increase their knowledge about rubber and FEM simulations of seals in ANSYS. The aim with this work is to develop a method and guidelines for analysis and simulation of seals of hyperelastic materials. Components analyzed in this thesis work are two static seals, an O-ring andan in-house modified X-ring design. Selected materials, HNBR and FKM, are commonly used elastomers at Volvo CE. Material tests performed at RISE are for three different load cases:uniaxial tension test, planar tension test and biaxial tension test. Quasi-static analyses are performed in ANSYS. Hyperelastic materials need different constitutive models, hyperelastic material models, to describe their material behavior and these are defined in terms of a strain energy density function.However, the challenge is to determine the material constants in the equation, to characterize the material properties, by processing test data. Research questions answered are ‘’What material tests are needed for hyperelastic materials?’’, ‘’How is the test data converted to work as input to ANSYS and obtain material constants?’’ and ‘’How is an appropriate material model selected for simulation in ANSYS?’’. The study shows the importance of that material test represents the condition the application will experience. It should capture material behavior at the specific frequency, strain amplitude and temperature range for the application. The expected strain range and deformation modes that will play a functional role in the application should be considered in the material testing. Material constants can be determined from test data separately or simultaneously. Test data from at least one deformation mode is required, but one can't accurately predict full deviatoric behavior of hyperelastic material models by using one mode. If data only is used for one deformation mode, simulations in other deformation modes can yield erroneous results. It is therefore recommended to use several deformation modes. For applications with more complex load cases more deformation modes are needed. Generally, recommended tests are uniaxial tension test, planar tension test and biaxial tension test due to homogenous deformation is achieved. It is important to verify the material model before analysis. Using test data from one deformation mode can still provide a good fit. In the cases investigated verifications of the material model Yeoh 3rd order show that the fit obtained by only using uniaxial tension test data and using test data from three tests doesn’t seem to differ. Both uniaxial tension test data and test data from three tests give agood fit when simulating the tests with this material model. The benefit of using test data from three tests is questionable due to costs. It seems that only uniaxial tension test data could have been used as it provided a good fit. Moreover, test data must be processed to work as input to ANSYS. ANSYS requires engineering stress-strain test data for hyperelastic materials besides from the volumetric test, where true stress strain is required. The biaxial tension state which is realized with so called Bulge test thus needs to be converted to engineering stress. Then, test data needs to be adjusted to account for effects such as hysteresis and Mullin’s effect, where choice of curve and a process zero-shift must be done. Hyperelastic material models have different validity for different strain ranges. The selected material model was Yeoh 3rd order, which showed be a good fit for both the materials, HNBR and FKM, in strain range 30 %. The curve fit is based on three tests. The selection was based on the material model with lowest relative error with stability. Material constants were obtained for that material model, and these were used in simulations. Material models tends to be unstable for strains outside the test data. Simulations of seals with fluid pressure were performed for different pressure and stretch of the seal. If the contact pressure is larger than fluid pressure in the seals no leakage will occur. / Hyperelasticitet är en betydande egenskap hos gummi, som används i tekniska tillämpningar. En vanlig tillämpning är tätningar för att förhindra vätskeöverföring (vätska eller gas) mellan fasta områden. Volvo CE är ofta beroende av externa leverantörer vid utveckling av tätningar. De vill därför med detta examensarbete öka sina kunskaper om gummi och FEM-simuleringar av tätningar i ANSYS. Målet med arbetet är att utveckla en metod och riktlinjer för analys och simulering av tätningar av hyperelastiska material. Komponenter som analyseras i detta examensarbete är två statiska tätningar, en O-ring och en intern modifierad X-ringdesign. Utvalda material, HNBR och FKM, är vanliga elastomerer hos Volvo CE. Materialtester som genomförts på RISE är för tre olika belastningsfall: enaxligt dragprov, plant dragprov och biaxialt dragprov. Quasi-statiska analyser genomfördes i ANSYS. Hyperelastiskt material behöver olika konstitutiva modeller, hyperelastsiska materialmodeller, för att beskriva dess materialbeteende och dessa definieras i termer av töjningsenergidensitetsfunktion. Utmaningen är att bestämma materialkonstanterna i ekvationen, för att karakterisera materialegenskaper, genom att processa testdatat. Forskningsfrågor som besvaras är ’’Vilka materialtester är nödvändiga för hyperelastiska material?’’, ’’Hur konverteras testdata för att fungera som indata till ANSYS och erhålla materialkonstanter?’’ och ’’Hur väljs lämplig materialmodell för simulering i ANSYS?’’. Studien visar vikten av att materialtester representerar förhållanden som är representativa för applikationen. Det bör fånga materialbeteendet vid den specifika frekvensen, töjningsamplitud och temperatur för applikationen. Det förväntade töjningsomårdet och deformationslägen som kommer spela en funktionell roll i applikationen bör beaktas i materialtestningen. Materialkonstanter kan beräknas från testdata separat eller simultant. Testdata från minst ett deformationsläge krävs, men man kan inte exakt förutsäga fullständigt devatoriskt beteende hos hyperelastiska materialmodeller genom att använda ett deformationsläge. Om testdata endast används för ett deformationsläge kan simuleringar i andra deformationslägen ge felaktiga resultat. Det är därför rekommenderat att använda flera deformationslägen. Generellt rekommenderade tester är enaxligt dragprov, plant dragprov och biaxialt dragprov då homogen deformation uppnås. Det är viktigt at verifiera materialmodellen innan analys. Att använda testdata från ett deformationsläge kan fortfarande ge en bra passning. I de undersökta fallen visar verifikation av materialmodellen Yeoh 3:e ordningen att passningen som erhållits av enbart enaxligt dragprovtestdata och testdata från tre tester inte skiljer sig åt. Både enaxligt dragprov testdata och testdata från tre tester ger en bra passning när simulerar testerna med den materialmodellen. Fördelarna med att använda testdata från tre tester är ifrågasatt pga. kostnaderna. Det verkar som enbart enaxligt dragprov testdata kunde ha använts då det gav en bra passning. Vidare behövs testdata hanteras för att fungera som indata till ANSYS. ANSYS behöver nominellspänning-töjning testdata för hyperelastiska material förutom för det volymetriska testet, där sannspänning-töjning behövs. Det biaxiala dragprovet som realiserades med s.k. Bulge test måste därför konverteras till nominell spänning. Sedan behöver testdata justeras för att ta hänsyn till effekter som hysteres och Mullins effekt, där val av kurva samt en process ‘’zero-shift’’ måste göras. Hyperelastiska materialmodeller har olika giltighet för olika töjningsområden. Val av materialmodell blev Yeoh 3:e ordningen som visade sig vara en bra passning för båda materialen, HNBR och FKM, i töjningsområden 30%. Kurvanpassningen är baserad på tre tester. Valet baserades på den materialmodell som hade minst relativt fel och som var stabil. Materialkonstanterer hölls för den materialmodellen och dessa användes i simuleringar. Materialmodeller tenderar att vara ostabila för töjningar utanför testdata. Simuleringar av tätningar med flödestryck genomfördes för olika tryck och stretch av tätningen. Om kontakttrycket är större än flödestrycket i tätningen sker inget läckage.
99

Investigating CIC-C1q ELISA for measuring in vitro activation of the complement system on intravenous immunoglobulin / Undersökning av CIC-C1q ELISA för mätning av in vitro-aktivering av komplementsystemet på intravenöst immunoglobulin

Giannoglou, Theodosis January 2023 (has links)
Octapharma tillverkar Octagam, en lösning innehållande humant immunglobulin för intravenös administrering, vars huvudkomponent är immunglobulin G (IgG). Aggregerade IgG förknippas med aktivering av komplementsystemet i frånvaro av antigen. Denna ospecifika aktivering av komplement har tidigare rapporterats orsaka biverkningar hos patienter. För att undvika detta använder Octapharmas laboratorium för kvalitetskontroll en metod som kallas test av antikomplementär aktivitet, för kontroll av batcher av Octagam innan de släpps ut på marknaden. Denna metod har flera problem, t.ex. låg tillgänglighet av viktiga reagens. Syftet med detta projekt var därför att undersöka om en alternativ metod, CIC-C1q ELISA, kunde mäta aktiveringen av komplementsystemet på immunglobuliner genom att testa olika batcher av IgG och värmebehandlade IgG-prover för att bedöma om det fanns en korrelation mellan resultaten från de två metoderna. Resultaten visade att det inte fanns någon korrelation mellan ACA-testet och CIC-C1q ELISA. Varken normala IgG-batcher eller värmebehandlade prover uppvisade någon tydlig korrelation. Den enda fördelen som C1q kan ha är att den gav ett högt resultat för en batch som tidigare har rapporterats orsaka biverkningar hos patienter, medan svaret i ACA-testet var relativt normalt. CIC-C1q ELISA metoden har dock visat sig ha sina egna problem eftersom standardprover ger inkonsekventa värden och mer tester behöver utföras för att hitta spädnings-linjäritet. / Octapharma manufactures Octagam, a liquid preparation of highly purified human immunoglobulin for intravenous administration, the main component of which is immunoglobulin G (IgG). Aggregated IgG is associated with activation of the complement system in the absence of antigen. This non-specific activation of complement has been reported to cause adverse reactions in patients. To avoid this, Octapharma's quality control laboratory uses a method called the determination of anti-complementary activity (ACA) in Immunoglobulin, for control of all batches of Octagam before release. This method has several problems, such as low availability of critical reagents. Therefore, the aim of this project was to investigate whether an alternative method, CIC-C1q ELISA, could measure the activation of the complement system on immunoglobulins by testing different batches of IgG and heat-treated IgG samples to assess whether there is a correlation between the results of the two methods. The results showed that there was no correlation between the ACA test and the CIC-C1q ELISA. Neither normal IgG batches nor heat-treated samples showed a clear correlation. The only advantage the C1q may have is that it gives a high response for a batch that has been reported to cause adverse reactions in patients, while the response in the ACA test was relatively normal. If this can be demonstrated by testing similar batches, it may be beneficial to continue testing the C1q ELISA. However, this method has also been shown to have its own problems, such as the standard sample giving inconsistent values, and more work is needed to find the linearity of the dilution.
100

Разработка методов для увеличения вовлеченности публикаций в Instagram : магистерская диссертация / Developing Methods to Increase the Engagement of Instagram Posts

Слинкина, О. В., Slinkina, O. V. January 2020 (has links)
За последние несколько лет социальные сети для компаний стали одним из основных инструментов работы с клиентами. Социальная сеть Instagram служит инструментом для бизнеса, но из-за высокой конкуренции и медленного обновления функционала сети, существуют проблемы качественной вовлеченности пользователей и автоматизированной работы с социальной сетью. Для решения данных проблем необходимо внедрить специальные инструменты и определить критерии эффективности публикаций в Instagram. Научная новизна. Перечислены актуальные методы для увеличения эффективности публикаций в социальной сети Instagram для бизнеса, выполнена практическая работа с существующими аккаунтами в Instagram, получены новые результаты при отслеживании активности в профилях, выделены новые потребности и задачи, которые должны решать инструменты для работы в Instagram. Практическая значимость исследования – заключается в разработке методов для увеличения эффективности продвижения бизнеса в социальных сетях, которые изложены в учебно-методическом пособие. Представлены данные на основе работы по аккаунту дополнительного образования «Сетевой инженерно-технической школы», подведены и составлены примеры протестированных публикаций. Проанализированы текущие инструменты для работы в Instagram, построена полная модель и выявлены проблемы в модели бизнес-процессов AS-IS. / Over the past few years, social networks have become one of the main tools for working with clients for companies. The social network Instagram serves as a tool for business, but due to high competition and slow updating of the network's functionality, there are problems of high-quality user engagement and automated work with the social network. To solve these problems, it is necessary to introduce special tools and determine the criteria for the effectiveness of posts on Instagram. Scientific novelty. The current methods for increasing the effectiveness of posts on the social network Instagram for business are listed, practical work has been done with existing Instagram accounts, new results have been obtained when tracking activity in profiles, new needs and tasks that must be solved by tools for working in Instagram are highlighted. The practical significance of the study lies in the development of methods to increase the effectiveness of business promotion in social networks, which are set out in the educational and methodological manual. The data on the basis of work on the account of additional education "Networked Engineering and Technical School" are presented, examples of tested publications are summarized and compiled. Analyzed the current tools for working on Instagram, built a complete model and identified problems in the AS-IS business process model.

Page generated in 0.0307 seconds