• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 423
  • 72
  • 27
  • 10
  • 8
  • 8
  • 8
  • 8
  • 3
  • 1
  • 1
  • Tagged with
  • 532
  • 147
  • 122
  • 113
  • 111
  • 110
  • 104
  • 101
  • 88
  • 82
  • 81
  • 79
  • 56
  • 54
  • 52
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Tratamento térmico dos amidos de batata-doce (Ipomoea batatas L.) e de mandioquinha-salsa (Arracaccia xanthorrhiza.) sob baixa umidade em microondas / Heat moisture treatment of sweet potato (Ipomoea batatas L.) and peruvian carrot (Arracaccia xanthorrhiza) starches in microwave oven

Gonçalves, Maria Flávia Vaz 29 August 2007 (has links)
O tratamento térmico sob baixa umidade (TTBU) induz modificações estruturais nos grânulos de amido, com conseqüente modificação de propriedades como a digestibilidade enzimática e as propriedades de pasta. O TTBU clássico é realizado em fornos convencionais a ar e é bastante moroso. Recentemente melhorias têm sido propostas ao método, visando satisfazer aos requerimentos práticos para a aplicação em escala industrial. A aplicação de microondas em diversos setores vem crescendo e tem como vantagens a economia de espaço e tempo, devido ao tipo e eficiência da energia. Assim, o objetivo deste trabalho foi avaliar o efeito do TTBU realizado em forno microondas sobre as propriedades estruturais e funcionais de amidos de batata-doce e de mandioquinha-salsa e compará-las com as propriedades desses mesmos amidos tratados pelo método convencional. Os amidos foram extraídos dessas tuberosas e submetidos à modificação física, nas umidades de 25 e 35%, em forno convencional (90ºC/16horas) e em microondas (35 a 90ºC/1 hora). Os amidos tratados foram avaliados quanto à composição macromolecular (amilose), aparência superficial do grânulo por microscopia eletrônica de varredura (MEV), cristalinidade (raio-x), digestibilidade enzimática ( -amilase pancreática de suíno), fator de expansão e propriedades de pasta (RVA). O TTBU não alterou a aparência superficial dos amidos ao microscópio. Após a modificação física, o teor de amilose do amido de batata-doce tratado no microondas não se diferenciou do amido natural, porém apresentou menor teor do que o amido tratado em forno em ambas as umidades. O amido de mandioquinha-salsa tratado em forno convencional permaneceu com o mesmo teor do amido natural, já o tratamento por microondas aumentou o teor de amilose. O TTBU aumentou a suscetibilidade enzimática dos grânulos, sendo o amido de batata-doce o mais suscetível à ação da enzima pelo tratamento em forno e o amido de mandioquinha-salsa pelo microondas. A umidade das amostras pareceu afetar mais que o tipo de tratamento térmico. Sob maior umidade, os amidos tiveram maior aumento da suscetibilidade enzimática. Embora tenham ocorrido alterações nos difratogramas de raio-x mais ou menos intensas em função dos tratamentos, os padrões de cristalinidade dos amidos de batata-doce (CB) e de mandioquinha-salsa (B) permaneceram inalterados após os tratamentos sob quaisquer das condições estudadas. Os grânulos de amido das tuberosas tratados por TTBU apresentaram redução do fator de expansão. A expansão foi menor no forno convencional do que no microondas. O tratamento térmico alterou as propriedades de pasta dos amidos, aumentando, de um modo geral, a temperatura de pasta, o tempo de pico, a viscosidade final e a tendência à retrogradação e diminuindo o pico de viscosidade e a quebra. As alterações conferidas pelo TTBU foram variáveis com o tipo de tratamento térmico, o teor de umidade e com a fonte de amido. Considerando que a qualidade de um amido é definida em função de sua finalidade de uso, pode-se optar dentre os tratamentos estudados, a intensidade de modificação desejada para o mesmo. / The heat moisture treatment (HMT) induces structural modifications on the granules of starch with consequent modification of properties such as the enzymatic digestibility as well as the paste properties. The classic HMT is run in air conventional ovens and is very slow. Recently improvements have been proposed to the method by aiming to satisfy the practical requirements for the application in industrial scale. The application of the microwave in several sectors has been growing and presents as advantages the economy of room and time due to the type and efficiency of the energy. In this way, the objective of this work has been to evaluate the effect of the HMT made in microwave on the structural and functional properties of the sweet potato and peruvian carrot starches and compare them to the properties of the same starches treated by the conventional method. The starches have been extracted from these tuberoses and when at 25 and 35% moisture, submitted to physical modification in conventional oven (90ºC/16 hours) and in microwave oven (35 to 90ºC/1 hours). The treated starches have been evaluated regarding their macromolecular (amylose), granules surface appearance by scanning electron microscope (SEM), crystallinity (xrays), enzymatic digestibility (porcine pancreatic -amyilase), swelling factor and paste properties (RVA). The HMT has not changed the surface appearance of the starched through microscope. After the physical modification, the amylose content of the sweet potato starch treated in microwave oven has not been different from the natural starch, however presented less content than the starch treated in microwave oven at both moistures. The peruvian carrot starch treated in conventional oven remained with the same content of the natural starch, but the treatment in microwave has increased the amylose content. The HMT has increased the granules enzymatic susceptibility; the sweet potato starch is the most susceptible to the action of the enzyme by the treatment in oven and the peruvian carrot starch by the microwave oven, The moisture of the samples seemed to affect more than the type of heat treatment. Under higher moisture, the starches has had highest increase to enzymatic susceptibility. Although more or less intense alterations in the x-rays diffractograms have occurred due to the treatments, the crystallinity patterns of the sweet potato (CB) and peruvian carrot (B) starches remained unchanged after the treatments under any of the studied conditions. The tuberoses granules starches treated by HMT have presented reduction on the sweeling factor. The sweeling has been lower in conventional oven than in microwaves. The heat treatment has changed the starches paste properties, in a general way, increasing the paste temperature, peak time, final viscosity and setback and decreasing the viscosity peak and breakdown. The alterations checked by the HMT have been variable according to the type of heat treatment, moisture content and source of starch. Considering that the quality of a starch is defined in conformity with its use purpose, it can be chosen the type of treatment among the studied ones and the intensity of desired modification for the starch.
352

Nuevos precursores de iluros de azometino para cicloadiciones 1,3-dipolares

Mancebo Aracil, Juan 07 March 2014 (has links)
En la presente memoria se describe la síntesis de derivados de pirrolidina, pirrolizidina e indolizidina mediante diferentes metodologías que involicruan una cicloadición 1,3-dipolar multicomponente a través de iluros de azometino generados in situ, así como el estudio cinético de esta reacción vía dos componentes. En el Capítulo I, se describen diferentes métodos de estudio cinético para la interpretación y obtención de parámetros mecanísticos de dicha reacción a partir de la información obtenida mediante Análisis Térmico y más concretamente calorimetría diferencial de barrido. En el Capítulo II, dividido en tres partes, se describe la síntesis de pirrolidinas mediante cicloadición 1,3-dipolar multicomponente (a partir de iluros de azometino) térmica y por irradiación por microondas (Parte 1), catalizada por plata(I) (Parte II) y asimétrica mediante catálisis por plata(I) y un ligando quiral (Parte III); así como la posible aplicabilidad en la síntesis de productos naturales o que presenten actividad biológica. En el Capítulo III, se describe la síntesis de pirrolizidinas mediante la cicloadición 1,3-dipolar multicomponente con iluros de azometino con y sin uso de sales de plata(I), así como un ejemplo en la construcción de un esqueleto de indolizidina siguiendo la misma metodología. Finalmente se incluyen las conclusiones junto con otro tipo de anexos como son las referencias, abreviaciones y la biografía.
353

Estudio teórico y experimental de la guía dieléctrica en banda invertida

Prieto Gala, Andrés 01 October 1979 (has links)
Se discute la guía dieléctrica en banda invertida como modificación capaz de aumentar el factor de calidad de la guía dieléctrica rectangular. En su configuración abierta se emplea para su estudio el método de la constante dieléctrica efectiva; se optimiza la geometría para conseguir el mayor ancho de banda posible y se discute la posibilidad de naturaleza espuerea para una parte de los modos encontrados. Se comprueba que el sistema de excitación clásico para guías dieléctricas no resulta valido para la guía en banda invertida y se optimiza un sistema de tipo cornete. Mediante un sistema de sonda móvil se mide la constante de propagación en la guía obteniéndose un buen acuerdo con las predicciones teóricas. Se estudia la guía dieléctrica cerrada en una caja mediante el método de Schelkunoff comprobándose la existencia de modos EH. / The inverted band dielectric waveguide is proposed as an alternative to the classical open dielectric waveguide, providing a higher quality factor. The dielectric effective constant method is used to study the open waveguide. In order to get the highest bandwith, the geometry is optimised, finding not real modes in the waveguide. It has been necessary to use a new excitation method of waveguide using a horn as transition. The measurement of the propagation constant has been made by means of an electric probe. The agreement with the theoretical predictions is very good. Finally the closed guide is studied by the Schelkunoff's method: modes EH were observed.
354

Efetividade da irradiação por microondas na desinfecção de próteses totais contaminadas por diferentes espécies de Candida isoladas de pacientes HIV positivo

Sanitá, Paula Volpato [UNESP] 26 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-26Bitstream added on 2014-06-13T19:16:49Z : No. of bitstreams: 1 sanita_pv_me_arafo.pdf: 1236296 bytes, checksum: 793fd4710489b2253297ebbc15835736 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estomatite protética associada à Candida é a forma mais comum de candidíase oral e também uma das infecções oportunistas mais encontradas em pacientes infectados por HIV. Atualmente, a desinfecção de próteses totais através da irradiação por microondas tem sido recomendada para tratamento e prevenção da estomatite protética, tanto em indivíduos saudáveis, quanto em pacientes imunocomprometidos. O presente estudo avaliou a efetividade da irradiação por microondas na desinfecção de próteses totais simuladas contaminadas com 5 diferentes espécies do microorganismo Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis e C. krusei) isoladas de culturas padrão e de pacientes HIV positivo. Para isso, próteses totais simuladas foram confeccionadas, esterilizadas por meio de óxido de etileno e individualmente inoculadas com os microorganismos avaliados. Após o período de incubação (48 horas a 37°C), as próteses foram submetidas à irradiação por microondas a 650W durante 3 minutos. Próteses totais não irradiadas foram utilizadas como controle positivo. A seguir, uma alíquota de 25 æL da solução resultante das diluições seriadas de 10-1 a 10-4 foi semeada em placas de Petri em duplicata e todas as placas foram incubadas por 48 horas a 37°C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por microondas a longo prazo, as próteses totais irradiadas foram incubadas a 37°C por 7 dias. Os resultados obtidos foram analisados estatisticamente pelos testes de ANOVA e de Tukey (a=0.05). As próteses totais contaminadas com todas as espécies de Candida avaliadas demonstraram esterilização após irradiação por microondas durante 3 minutos a 650W. Todas as próteses do grupo controle positivo demonstraram crescimento microbiológico após incubação nas placas de Petri. / The most common form of oral candidiasis is Candida-associated denture stomatitis. Oral candidiasis is also a frequent manifestation of HIV infection. Microwave disinfection of complete dentures has been recommended to treat and prevent denture stomatitis in non-immune compromised patients. The present study evaluated the effectiveness of microwave irradiation on the disinfection of simulated complete dentures inoculated with ATCC and HIV isolates of 5 species of Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis and C. krusei). Simulated complete dentures were made, sterilized and individually inoculated with the tested microorganisms. After incubation for 48 hours at 37°C, dentures were submitted to microwave irradiation (650W for 3 minutes). Non-irradiated dentures were used as positive controls. Replicate aliquots of suspensions were plated at dilutions 10-1-10-4 and incubated for 48 hours at 37°C. Colonies counts (cfu/mL) of each plate were quantified. To verify the long-term effectiveness of microwave disinfection, dentures were incubated at 37°C for 7 days. Data were analyzed with two-way ANOVA and Tukey HSD tests (a=0.05). The results indicated that complete dentures contaminated with all Candida yeasts showed sterilization after microwave irradiation for 3 minutes at 650W. All control dentures showed microbial growth on the plates. The cfu/mL for C. glabrata was significantly higher than those of C. albicans, C. dubliniensis and C. tropicalis whereas the cfu/mL for C. krusei was significantly lower. The cfu/mL for clinical isolates was significantly higher than those of ATCC yeasts. Microwave irradiation for 3 minutes at 650W resulted in sterilization of complete dentures contaminated with the 5 species of Candida isolated from HIV-infected patients.
355

Efetividade de duas soluções desinfetantes e da irradiação por micro-ondas na desinfecção de próteses totais contaminadas com staphylococcus aureus resistente à meticilina (MRSA)

Altieri, Karen Tereza [UNESP] 28 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-28Bitstream added on 2014-06-13T20:18:32Z : No. of bitstreams: 1 altieri_kt_me_arafo.pdf: 598917 bytes, checksum: 3b01564a77c1be4471454056881b7028 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Infecções causadas por bactérias resistentes a antibióticos são consideradas causa principal de mortalidade entre indivíduos imunocomprometidos e aproximadamente 50 % destas infecções tem sido relacionadas ao Staphylococcus aureus resistente à meticilina (MRSA). Estes microrganismos, quando presentes no biofilme das próteses dentarias, podem se dispersar nas secreções salivares e se disseminar pelo trato respiratório, causando pneumonia aspirativa. Assim, o presente estudo comparou a efetividade do hipoclorito de sódio a 1 %, digluconato de clorexidina a 2 % e irradiação por micro-ondas na desinfecção de próteses totais e corpos-de-prova circulares de resina acrílica para base de prótese (10 x 2 mm) contaminados com MRSA. Para isso, 36 próteses totais simuladas e 36 corpos-de-prova circulares foram confeccionados, esterilizados, inoculados com MRSA (107 ufc/mL) e incubados a 37 °C (por 24 e 48 h, respectivamente). Após incubação, próteses totais e corpos-de-prova foram distribuídos em 4 grupos de estudo (n=9): GC - não foi realizado nenhum método de desinfecção; GH - foi realizada a imersão em solução de hipoclorito de sódio a 1 % por 10 min; GCl -foi realizada a imersão em solução de digluconato de clorexidina a 2 % por 10 min; GM - foi realizada a desinfecção por irradiação em forno de micro-ondas a 650 W por 3 min. A efetividade dos procedimentos de desinfecção foi avaliada por meio de quantificação de colônias viáveis e da viabilidade celular. Para a quantificação de colônias viáveis, alíquotas de 25 μL da solução resultante das diluições seriadas (10-3 a 10-6 para GC e 100 a 10-3 para os grupos experimentais) foram semeadas em placas de Petri em duplicata e todas as placas foram incubadas por 48 h a 37 °C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por micro-ondas em longo prazo... / Infections caused by antibiotic-resistant bacteria have been recognized as a predominant risk factor for mortality in elderly patients and approximately 50 % of these infections have been related to methicillin-resistant Staphylococcus aureus (MRSA). This microorganism, when present in the denture biofilm, can be released into the oral fluids and aspirated into the lower respiratory tract, thus causing infections such as aspiration pneumonia. The present study compared the efficacy of 1 % sodium hypochlorite, 2 % chlorhexidine gluconate, and microwave irradiation in disinfecting simulated complete dentures and circular specimens of acrylic resin denture base material (10 x 2 mm) contaminated with MRSA. Thirty-six dentures and 36 specimens were made, sterilized, inoculated with MRSA (107 cfu/mL), and incubated at 37 °C (for 24 and 48 h, respectively). After incubation, dentures and specimens were divided into 4 groups of study (n=9): PC - positive control, consisting of dentures and specimens not disinfected; HY - soaking in 1 % sodium hypochlorite solution for 10 min; CHL - soaking in 2 % chlorhexidine gluconate solution for 10 min; and MW - irradiating by microwave for 3 min at 650W. The effectiveness of the disinfection procedures was assessed cell viability (quantification of viable cells and XTT reduction method). For quantification procedures, aliquots of suspensions were plated at dilutions (10-3 to 10-6 for PC and 100 to 10-3 for experimental groups) and incubated (37 °C/48 h). Colonies counts (cfu/mL) were quantified. Dentures disinfected were also incubated at 37 °C for 7 days to verify the long-term effectiveness of disinfection. The viability of cells in each group of specimens was evaluated by XTT reduction method. The results showed that all dentures and specimens from the PC groups showed substantial microbial growth. No evidence of microbial growth was observed... (Complete abstract click electronic access below)
356

Influ?ncia do uso de combust?veis alternativos na s?ntese por combust?o via microondas para a produ??o de materiais cer?micos com estrutura espin?lio

Silva, Walquiria Joseane da 21 July 2011 (has links)
Made available in DSpace on 2014-12-17T14:06:58Z (GMT). No. of bitstreams: 1 WalquiriaJS_DISSERT_PACIAL.pdf: 740304 bytes, checksum: 3d1d601a3873230ed2af2ce67496fdf5 (MD5) Previous issue date: 2011-07-21 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The development and study of detectors sensitive to flammable combustible and toxic gases at low cost is a crucial technology challenge to enable marketable versions to the market in general. Solid state sensors are attractive for commercial purposes by the strength and lifetime, because it isn t consumed in the reaction with the gas. In parallel, the use of synthesis techniques more viable for the applicability on an industrial scale are more attractive to produce commercial products. In this context ceramics with spinel structure were obtained by microwave-assisted combustion for application to flammable fuel gas detectors. Additionally, alternatives organic-reducers were employed to study the influence of those in the synthesis process and the differences in performance and properties of the powders obtained. The organic- reducers were characterized by Thermogravimetry (TG) and Derivative Thermogravimetry (DTG). After synthesis, the samples were heat treated and characterized by Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffraction (XRD), analysis by specific area by BET Method and Scanning Electron Microscopy (SEM). Quantification of phases and structural parameters were carried through Rietveld method. The methodology was effective to obtain Ni-Mn mixed oxides. The fuels influenced in obtaining spinel phase and morphology of the samples, however samples calcined at 950 ?C there is just the spinel phase in the material regardless of the organic-reducer. Therefore, differences in performance are expected in technological applications when sample equal in phase but with different morphologies are tested / O desenvolvimento e estudo de detectores sens?veis a gases combust?veis inflam?veis e t?xicos de baixo custo ? um desafio tecnol?gico determinante para possibilitar vers?es comercializ?veis ao mercado em geral. Sensores no estado s?lido s?o atrativos para fins comerciais pela robustez e tempo de vida, uma vez que n?o s?o consumidos durante o processo de rea??o com o g?s. Paralelamente, o uso de t?cnicas de s?ntese mais vi?veis pela aplicabilidade em escala industrial s?o mais atrativas para obten??o de produtos comerciais. Dentro desse contexto foram obtidos materiais cer?micos com estrutura espin?lio via combust?o assistida por microondas, visando aplica??o em detectores de gases combust?veis inflam?veis. Adicionalmente foram empregados direcionadores-org?nicos alternativos para estudo da influ?ncia dos mesmos no processo de s?ntese e nas diferen?as nas propriedades e desempenho dos p?s obtidos. Os direcionadores-org?nicos foram caracterizados por Termogravimetria (TG). Ap?s a s?ntese, as amostras foram tratadas termicamente e caracterizadas por Espectroscopia de absor??o na regi?o do infravermelho com Transformada de Fourier (FTIR), Difra??o de Raios X (DRX), Medidas de ?rea espec?fica por BET e Microscopia Eletr?nica de Varredura (MEV). A quantifica??o de fases e a determina??o de par?metros estruturais foram determinados por refinamento atrav?s do M?todo Rietveld. A metodologia empregada foi eficaz para obten??o de ?xidos mistos Ni-Mn. Os combust?veis utilizados influenciaram na obten??o da fase espin?lio e na morfologia das amostras, sendo que as amostras calcinadas a 950?C s?o monof?sicas independentemente do direcionador. Logo, diferen?as de desempenho s?o esperadas em aplica??es tecnol?gicas quando amostras iguais em fase mas com diferentes morfologias s?o testadas
357

S?ntese de catalisadores do tipo LaNixFe1-xO3 como precursores catal?ticos para rea??o oxida??o parcial do metano

Martinelli, Daniele de Macedo Henrique 21 February 2011 (has links)
Made available in DSpace on 2014-12-17T14:07:05Z (GMT). No. of bitstreams: 1 DanieleMHM_TESE.pdf: 1582500 bytes, checksum: bba4e28b78ed6df0658bf0c3609ea506 (MD5) Previous issue date: 2011-02-21 / Nickel-bases catalysts have been used in several reform reactions, such as in the partial oxidation of methane to obtain H2 or syngas (H2 + CO). High levels of conversion are usually obtained using this family of catalysts, however, their deactivation resulting from carbon deposition still remains a challenge. Different approaches have been tested aiming at minimizing this difficulty, including the production of perovskites and related structures using modern synthesis methods capable of producing low cost materials with controlled microstructural characteristics at industrial scale. To establish grounds for comparison, in the present study LaNixFe1-xO3 (x=0, 0.3 or 0.7) perovskites were prepared following the Pechini method and by microwave assisted self-combustion. All samples were sub sequently calcined at 900 ?C to obtain the target phase. The resulting ceramic powders were characterized by thermogravimetric analysis, infrared spectroscopy, X ray diffraction, specific area and temperature programmed reduction tests. Calcined samples were also used in the partial oxidation reaction of methane to evaluate the level of conversion, selectivity and carbon deposition. The results showed that the calcined samples were crystalline and the target phase was formed regardless of the synthesis method. According to results obtained by Rietveld refinement, we observed the formation of 70.0% of LaNi0.3Fe0.7O3 and 30.0% of La2O3 for samples LN3F7-900- P, LN3F7-900-M and 41,6% of LaNi0.7Fe0.3O3, 30.7% of La2NiO4 and 27.7% of La2O3 for samples LN7F3-900-P and LN7F3-900-M.Temperature-programmed profiles of the LaNiO3 sample revealed the presence of a peak around 510 ?C, whereas the LaFeO3 sample depicted a peak above 1000?C. The highest l evel of methane conversion was obtained for LaNiO3 synthesized by the Pechini method. Overall, catalysts prepared by the Pechini method depicted better conversion levels compared to those produced by microwave assisted self-combustion / Catalisadores a base de n?quel t?m sido empregados em diversos tipos de rea??es de reforma, inclusive na oxida??o parcial do metano para obten??o de H2 ou g?s de s?ntese (H2 + CO). Normalmente, altos n?veis de convers?o s?o obtidos por estes catalisadores, entretanto, a desativa??o por deposi??o de carbono ainda ? um problema a ser solucionado. Diversas abordagens t?m sido empregadas no intuito de minimizar este problema, dentre as quais tem se destacado nos ?ltimos anos a utiliza??o de ?xidos com estrutura perovisquita e/ou estruturas relacionadas. Paralelamente, o uso de metodologias de s?nteses mais r?pidas, f?ceis, aplic?veis em escala industrial e que permitam o controle das caracter?sticas microestruturais destes catalisadores, pode em conjunto, prover a solu??o para este problema. A n?vel de compara??o perovisquitas do tipo LaNixFe1-xO3 (x=0, x=0,3 e x=0,7) foram preparados por dois m?todos: precursores polim?ricos (pechini) e autocombust?o assistida por microondas. Todas as amostras foram calcinadas a 900 ?C/4h para obten??o das fases desejadas. Os p?s-obtidos foram caracterizados por an?lise termogravim?trica, espectroscopia na regi?o do infravermelho, difra??o de raios-X, medidas de ?rea superficial especifica, redu??o ? temperatura programada. As amostras calcinadas foram testadas na rea??o de oxida??o parcial do metano, sendo avaliados os respectivos n?veis de convers?o, seletividade e a resist?ncia ? deposi??o de carbono. Ap?s calcina??o a fase desejada foi obtida para todas as amostras independente do m?todo de s?ntese, sugerindo claramente a forma??o de p?s cristalinos. De acordo com o resultados obtidos pelo refinamento Rietveld, observou-se a forma??o de 70,0% de LaNi0,3Fe0,7O3 e 30,0 % de La2O3 para as amostras LN3F7-900-P e LN3F7-900-M e 41,6% de LaNi0.7Fe0.3O3; 30,7% de La2NiO4 e 27,7 % de La2O3 para as amostras LN7F3-900-P e LN7F3-900-M. Os perfis de redu??o ? temperatura programada da amostra LaNiO3 apresentou pico de redu??o em torno de 510 ?C, j? a amostra LaFeO 3 apresentou pico de redu??o acima de 1000?C. Dentre os catalisadores estudados o que apresentou maior n?vel de convers?o de metano foi LaNiO3 obtido pelo m?todo pechini, de uma maneira geral os catalisadores obtidos pelo m?todo pechini apresentaram melhores resultados de convers?o que os catalisadores obtidos pela autocombust?o assistida por microondas
358

S?ntese e caracteriza??o de ferrita ni-zn pelo m?todo dos precursores polim?ricos calcinada por energia de microondas

Assis, Raimison Bezerra de 04 July 2013 (has links)
Made available in DSpace on 2014-12-17T14:07:12Z (GMT). No. of bitstreams: 1 RaimisonBA_DISSERT.pdf: 2147079 bytes, checksum: db6881c15458f1e487de74465b7088a0 (MD5) Previous issue date: 2013-07-04 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Magnetic ceramics have been widely investigated, especially with respect to intrinsic and extrinsic characteristics of these materials. Among the magnetic ceramic materials of technological interest, there are the ferrites. On the other hand, the thermal treatment of ceramic materials by microwave energy has offered various advantages such as: optimization of production processes, high heat control, low consumption of time and energy among others. In this work were synthesized powders of Ni-Zn ferrite with compositions Ni1- xZnxFe2O4 (0.25 ≤ x ≤ 0.75 mols) by the polymeric precursor route in two heat treatment conditions, conventional oven and microwave energy at 500, 650, 800 and 950?C and its structural, and morphological imaging. The materials were characterized by thermal analysis (TG/ DSC), X-ray diffraction (XRD), absorption spectroscopy in the infrared (FTIR), scanning electron microscopy (SEM), X-ray spectroscopy and energy dispersive (EDS) and vibrating sample magnetometry (VSM). The results of X-ray diffraction confirmed the formation of ferrite with spinel-type cubic structure. The extrinsic characteristics of the powders obtained by microwave calcination and influence significantly the magnetic behavior of ferrites, showing particles ferrimagn?ticas characterized as soft magnetic materials (soft), is of great technological interest. The results obtained led the potential application of microwave energy for calcining powders of Ni-Zn ferrite / Cer?micas magn?ticas t?m sido amplamente investigadas, principalmente com rela??o as caracter?sticas intr?nsecas e extr?nsecas destes materiais. Dentre os materiais cer?micos magn?ticos de interesse tecnol?gico, destacam-se as ferritas. Por outro lado, o tratamento t?rmico de materiais cer?micos por energia de microondas tem oferecido diversas vantagens, tais como: otimiza??o dos processos de obten??o, alto controle de aquecimento, menor consumo de tempo e energia entre outras. Neste trabalho, foram sintetizados p?s de ferritas Ni-Zn com composi??es Ni1-xZnxFe2O4 (0,25 ≤ x ≤ 0,75 mols) pela rota dos precursores polim?ricos em duas condi??es de tratamento t?rmico, em forno convencional e por energia de microondas a 500, 650, 800 e 950?C, e sua caracteriza??o estrutural, morfol?gica e magn?tica. Os materiais obtidos foram caracterizados por an?lises t?rmicas (TG/DSC), difra??o de raios x (DRX), espectroscopia de absor??o na regi?o do infravermelho (FTIR), microscopia eletr?nica de varredura (MEV), espectroscopia de raios X por dispers?o de energia (EDS) e magnetometria de amostra vibrante (VSM). Os resultados da difra??o de raios X confirmaram a forma??o da ferrita com estrutura c?bica do tipo espin?lio. As caracter?sticas extr?nsecas dos p?s obtidos e a calcina??o por microondas influenciaram de forma significativa o comportamento magn?tico das ferritas, apresentando part?culas ferrimagn?ticas, caracterizadas como materiais magn?ticos moles (macias), sendo de grande interesse tecnol?gico. Os resultados obtidos induziram o potencial de aplica??o de energia de microondas para a calcina??o de p?s de ferritas Ni-Zn
359

Efeito da adi??o de grafite expandido por microondas nas propriedades t?rmicas, el?tricas e mec?nicas de nanocomp?sitos de matriz ep?xi

Marinho, Ant?nio Calmon de Ara?jo 26 February 2014 (has links)
Made available in DSpace on 2014-12-17T14:07:16Z (GMT). No. of bitstreams: 1 AntonioCAM_DISSERT.pdf: 2526278 bytes, checksum: 858d8dc4858eb48a9d6ce6faab8763d4 (MD5) Previous issue date: 2014-02-26 / Universidade Federal do Rio Grande do Norte / Epoxy based nanocomposites with 1 wt % and 3 wt % of nanographite were processed by high shear mixing. The nanographite was obtained by chemical (acid intercalation), thermal (microwave expansion) and mechanical (ultrasonic exfoliation) treatments. The mechanical, electrical and thermal behavior of the nanocomposites was determined and evaluated as a function of the percentage of reinforcement. According to the experimental results, the electrical conductivity of epoxy was not altered by the addition of nanographite in the contents evaluated. However, based on the mechanical tests, nanocomposites with addition of 1 wt.% and 3 wt.% of nanographite showed increase in tensile strength of 16,62 % and 3,20 %, respectively, compared to the neat polymer. The smaller increase in mechanical strength of the nanocomposite with 3 wt.% of nanographite was related to the formation of agglomerates. The addition of 1 wt.% and 3 wt.% of nanographite also resulted in a decrease of 6,25 % and 17,60 %, respectively, in the relative density of the material. Thus, the specific strength of the nanocomposites was approximately 33,33 % greater when compared to the neat polymer. The addition of 1 wt.% and 3 wt.% of nanographite in the material increased the mean values of thermal conductivity in 28,33 % and 132,62 %, respectively, combined with a reduction of 26,11 % and 49,80 % in volumetric thermal capacity, respectively. In summary, it has been determined that an addition of nanographite of the order of 1 wt.% and 3 wt.% produced notable elevations in specific strength and thermal conductivity of epoxy / Nanocomp?sitos a base de resina ep?xi e nanografite foram processados por mistura de alto cisalhamento, com concentra??es de 1 % e 3 % p/p de refor?o. O nanografite foi obtido atrav?s de tratamentos: qu?mico (intercala??o ?cida), t?rmico (expans?o por microondas) e mec?nico (esfolia??o por ultrassom). Os comportamentos mec?nico, el?trico e t?rmico dos materiais obtidos foram analisados em fun??o da porcentagem de refor?o. De acordo com os resultados obtidos, n?o foram verificadas altera??es na condutividade el?trica do ep?xi com a adi??o de nanografite, nos percentuais estudados. Entretanto, com base nos ensaios mec?nicos observou-se que os nanocomp?sitos com adi??o de 1 % p/p e 3 % p/p de grafite expandido apresentaram aumento na resist?ncia ? tra??o de 16,62 % e 3,20 % respectivamente, em rela??o ao pol?mero puro. O menor aumento de resist?ncia mec?nica para os nanocomp?sitos com 3 % p/p de nanografite foi relacionado com a forma??o de aglomerados. A adi??o de 1 % p/p e 3% p/p de nanografite tamb?m resultou em uma diminui??o de 6,25 % e 17,60 %, respectivamente, na densidade relativa do pol?mero. Portanto, a eleva??o da resist?ncia espec?fica dos nanocomp?sitos foi de aproximadamente 33,33% para os dois nanocomp?sitos, em rela??o ao pol?mero puro. A adi??o de 1 % p/p e 3 % p/p de nanografite no material aumentou os valores m?dios de condutividade t?rmica em 28,33 % e 132,62 %, respectivamente, combinado com uma redu??o de 26,11 % e 49,80 %, respectivamente, na capacidade t?rmica volum?trica. Em resumo, verificou-se que uma adi??o de nanografite da ordem de 1 % e 3 % p/p produziram eleva??es not?veis na resist?ncia mec?nica espec?fica e condutividade t?rmica do ep?xi
360

Desinfecção de próteses totais por micro-ondas : efeito da frequência de irradiação no tratamento da estomatite protética /

Silva, Mariana Montenegro. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Cláudia Pavarina / Banca: Elaine Maria Sgavioli Massucato / Banca: Helena de Freitas Oliveira Paranhos / Banca: Karin Hermana Neppelenbroek / Resumo: A estomatite protética é uma infecção fúngica que acomete entre 60% e 72% dos indivíduos portadores de próteses removíveis, sobretudo idosos do gênero feminino. Atualmente, a desinfecção de próteses totais por meio da irradiação por micro-ondas tem sido recomendada para tratamento e prevenção da estomatite protética. Considerando esses aspectos, esse estudo in vivo avaliou a efetividade da frequência da desinfecção de próteses totais por micro-ondas (3 min/650 W) em relação à terapia antifúngica tópica para o tratamento da estomatite protética, além de verificar a prevalência de Candida nos pacientes avaliados. Para isso, foram selecionados 60 indivíduos, portadores de próteses totais superiores e com diagnóstico clínico de estomatite protética. Esses pacientes foram aleatoriamente distribuídos em 3 grupos (n=20), de acordo com o tratamento instituído: Terapia Antifúngica Tópica (Grupo I) - utilização de nistatina (suspensão oral, 100.000 UI/mL), 4 vezes ao dia durante 15 dias; Irradiação por Micro-ondas - imersão das próteses totais em água e irradiação das próteses por micro-ondas durante 3 minutos a 650 W, 1 ou 3 vezes por semana (Grupos II e III, respectivamente) por um período de 15 dias. Para avaliação da efetividade dos tratamentos instituídos, foram realizadas culturas micológicas quantitativas e identificação das espécies de Candida, utilizando-se o meio CHROMagar Candida, análise de microcultivo, teste de triagem em caldo hipertônico e o sistema bioquímico de identificação ID 32C. Coletas de biofilme das superfícies internas das próteses totais superiores e das mucosas palatinas de todos os pacientes, foram realizadas previamente ao tratamento (dia 0) e após 15 dias do seu início. Com o objetivo de avaliar a efetividade dos tratamentos em longo prazo, a quantificação de colônias viáveis de Candiada spp... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Denture stomatitis is a fungal infection that affects 60% to 72% of individuals who use removable dentures, primarily elderly women. Currently, the disinfection of complete dentures using microwave irradiation has been recommended to treat and prevent denture stomatitis. Considering these aspects, this in vivo study evaluated the effectiveness of the frequency of complete denture disinfection using microwaves (3 min/650 W) compared to antifungal therapy for the treatment of denture stomatitis. It also verified the prevalence of Candida spp. in the evaluated patients. This study used a sample of 60 healthy individuals who use complete upper dentures and have received a clinical diagnosis of denture stomatitis. Patients were randomly distributed into three groups (n=20), based on the treatment used: Topical Antifungal Therapy (Group I) - use of nystatin (oral suspension, 100.000 UI/mL), four times a day for 15 days; Irradiation with Microwaves - irradiation of the dentures by microwaves for three minutes at 650 W, one time or three times per week (Groups II and III, respectively) for a period of 15 days. In order to evaluate the effectiveness of the treatments used, quantitative mycological cultures were collected and the Candida species were identified using the CHROMagar Candida method, microculture analysis, screening test in hypertonic broth and the ID 32C biochemical identification system. Biofilm samples were collected from the inner surfaces of the complete upper dentures and from the palatal mucosa of all patients before (day 0) and after 15 days of treatment. In order to evaluate the effectiveness of the treatments over the long term, the quantification of the viable Candiada spp. colonies was repeated 30, 60 and 90 days after starting the treatment. For each consultation (days 0, 15, 30, 60 and 90), a clinical evaluation was also performed through intra-oral photography... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0531 seconds