• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 14
  • 7
  • 1
  • Tagged with
  • 61
  • 27
  • 25
  • 25
  • 22
  • 21
  • 21
  • 20
  • 18
  • 16
  • 15
  • 14
  • 13
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Zeolites as key-components for electronics and biomedicine / Zéolithes comme composants clés pour l'électronique et la biomédecine

Lülf, Henning 13 December 2013 (has links)
La thèse intitulée « Zeolites as key-components for electronics and biomedicine » traite de travaux sur des cristaux de zéolite-L avec des tailles et des formes différentes pour des applications dans les domaines de l’électronique et de la biomédecine. Il a été montré que, lorsque les monocouches de zéolites-L sont munies d’un biofilm, elles peuvent être utilisées comme des substrats pour une croissance de longue durée de neurones primaires. De plus, les pores des zéolites peuvent être remplies d’un spécial semi-conducteur organique, pour permettre un transport d’électrons à travers les canaux et, plus important, ces matériaux présentent une très haute magnétorésistance en y appliquant un champ magnétique externe. Enfin, les monocristaux de zéolites-L peuvent être utilisés en tant que plateforme pour un oligo-nucléotide multifonctionnel et l’administration d’un médicament-modèle à l’intérieur de cellules vivantes. Les oligo-nucléotides sont attachés aux particules de la surface externe et le médicament modèle est encapsulé dans les pores. Ces premières expériences-modèles confirment que ces systèmes offrent un grand potentiel dans le domaine de la thérapie génique. En résumé, cette thèse montre que les cristaux de zéolites-L peuvent être appliqués avec succès dans des domaines très variés, de l’électronique à la biomédecine. / The aim of this thesis titled “Zeolites as key-components for electronics and biomedicine” is the synthesis, functionalization and applications of zeolite-L particles for applications in electronics and biomedicine. This thesis is organized into 8 chapters, starting in chapter 1 with giving a general overview about nanotechnology and biomedicine. After that the concept of using nanocontainer in biomedicine are briefly discussed. In the following the nanocontainer zeolite-L is introduced and a summary of zeolite- L for applications in nanomedicine is given. Finally, the self-assembly of zeolites in monolayers and their further functionalization is discussed. Chapter 2 describes the zeolite-L synthesis, functionalization and their assembly into functional materials in detail. Three different types of zeolite-L have been used in this thesis: Nanozeolite-L particles with a size of just a few tenths of nanometers, disc-shaped zeolite-L with a diameter of around 200 nm and micrometer sized crystals with a length of about 1000 nm. Then different methods to functionalize the crystals with the desired groups and to obtain specific properties of the crystals are reported. In detail, the exchange with different counter cations, the insertion of guest molecules and the functionalization of the external crystal surface are reported. Finally the assembly into monolayers and their further functionalization by soft lithography is discussed. [...]
12

Le graphène comme barrière tunnel : propriétés d'injection de charges et de spin / Graphene as tunnel barrier : charge and spin injection properties

Godel, Florian 08 December 2015 (has links)
Mes travaux de thèse portent sur la fabrication et la caractérisation électrique et magnétique de jonctions tunnel à base de graphène. C’est autour de l’idée d’apporter une meilleur compréhension des mécanismes d’injection et de détection d’un courant de charge et de spin aux interfaces graphène/ferromagnétique que s’articule ce manuscrit. Après avoir démontré qu’il est possible de faire croître de manière épitaxiée une barrière tunnel de MgO sur graphène, nous avons étudié les mécanismes de transport dépendant en spin dans des jonctions verticales de Co/MgO/Gr/Ni. Nous avons mis en évidence l’interaction du graphène avec l’électrode de nickel à travers les inversions de signe de la magnétorésistance. Celles-ci peuvent être expliquées à l’aide d’un modèle de canaux de conduction assistés par phonons. Enfin du blocage de Coulomb reproductible a été mesuré dans des amas d’aluminium potentiellement mono disperses et auto assemblés sur graphène. / My PhD thesis deals with the fabrication and the electric and magnetic characterizations of magnetic tunnel junctions based on graphene. The interaction of graphene with its close environment opens new possibilities for spintronics applications. The manuscript is focused on the improvement of the understanding of mechanisms involved in the injection and detection of a polarized spin current at the graphene/ferromagnetic interfaces. We show that it is possible to grow epitaxially MgO tunnel barrier on graphene. We study the spin transport mechanisms in vertical junctions of Co/MgO/Gr/Ni. The interaction of graphene with nickel electrode is probed through tunnel magnetoresistance inversions which can be explained by the activation of phonon assisted conduction channel. We also measure in vertical and lateral devices based on alumina barrier on graphene, reproducible Coulomb blockade processes linked to the presence of monodisperse aluminum clusters at the graphene edge.
13

Jonctions tunnel magnétiques avec des monocouches moléculaires auto-assemblées / Magnetic tunnel junctions based on self-assembled monolayers

Delprat, Sophie 30 June 2017 (has links)
Le sujet de cette thèse concerne la spintronique moléculaire. Des jonctions tunnel magnétiques formées par une barrière tunnel moléculaire (monocouche auto-assemblée) insérée entre deux électrodes métalliques ferromagnétiques ont été étudiées. Afin de fabriquer les dispositifs, un procédé de greffage des molécules sur des substrats ferromagnétiques a été mis en place et une technique de lithographie a été développée pour définir des jonctions de taille submicronique. L’ensemble de ce travail expérimental a permis l’obtention de jonctions non court-circuitées et mesurables, où le transport électronique est bien du transport par effet tunnel.Les mesures de magnétotransport de ces échantillons ont amené des résultats intéressants et nouveaux : les jonctions, dont la barrière est formée par des alcanes-thiols, présentent de la magnétorésistance à température ambiante, allant jusqu’à 12%. Une partie de la thèse s’attelle à la compréhension des différents comportements magnétorésistifs observés : un modèle de barrière tunnel à deux niveaux est proposé pour les décrire.La dernière partie du travail présente des résultats préliminaires obtenus lorsque la barrière moléculaire est formée par des molécules aromatiques ou commutables et met en évidence des phénomènes nouveaux par rapport au cas précédent.L’ensemble des résultats prouve le fonctionnement de jonctions tunnel magnétiques à base de monocouches moléculaires à température ambiante et ouvre la voie à l’utilisation de molécules plus complexes pour une électronique de spin moléculaire multifonctionnelle. / This thesis work enters within the molecular spintronic fields. Magnetic tunnel junctions based on molecular self assembled monolayers have been investigated. The devices structure is a molecular monolayer inserted between two ferromagnetic electrodes.A process to graft molecules on a ferromagnet’s surface and a lithography technique have been developed to define the junctions. This experimental work has led to non short-circuited and measurable junctions, in which an electronic tunnel transport has been demonstrated.Interesting and new results have been found out from magnetoresistance measurement of the samples: junctions made with alkanes-thiols barrier have shown magnetoresistance signal at room temperature (up to 12%). In order to explain the magnetoresistive behaviour, a simple model where the barrier is discribed by two levels has been proposed.The last part of the thesis reports preliminary results obtained when the barrier is made of aromatic molecules or switchable molecules and it points out new phenomenons compared to the alkanes case.The overall work proves that devices made from magnetic tunnel junctions with self-assembled monolayers work at room temperature. It is then possible to consider switchable molecules to build multifunctional molecular spintronics devices.
14

Tenseur de mobilité et magnétothermoélectricité anisotrope de bismuth / Mobility tensor and anisotropic magnetothermoelectricity of bismuth

Collaudin, Aurelie 27 October 2014 (has links)
La surface de Fermi du bismuth est composée d'une poche de trous parabolique et de trois vallées d'électrons de Dirac équivalentes à une rotation près. Leur masse effective est faible (m* ~ 10-3 me) et très anisotrope (m1 ~ 200 m2). Ces propriétés électroniques remarquables, combinées à une densité de porteurs très faible (n=3.10-17 cm-3) et une très grande mobilité (µ ~ 108 cm2/V/s), impliquent que la magnétorésistance du bismuth est très grande et très sensible à l'orientation du champ magnétique. Au cours de cette thèse, nous avons réalisé la cartographie en température et champ magnétique de la dépendance angulaire de la magnétorésistance transverse dans les trois plans de haute symétrie. Nous avons ensuite confronté nos données aux attentes du modèle semi classique. Cela a permis de vérifier la pertinence du modèle semi-classique d'une part et d'extraire les composantes du tenseur de mobilité d'autre part. Nous trouvons que toutes les composantes du tenseur de mobilité suivent une dépendance en température qui est proche de T-2, suggérant la prédominance de l'interaction électron-électron. Une transition de phase au cours de laquelle la dépendance angulaire de la magnétorésistance perd la symétrie rotationnelle du réseau cristallin a été mise en évidence. L'étude de la dépendance angulaire de l'effet magnéto-Seebeck a révélé des oscillations similaires à celles de la résistivité. Leur explication nécessite d'aller au-delà du modèle semi-classique. Finalement, l'anisotropie et l'évolution avec le champ magnétique du pouvoir thermoélectrique et de la figure de mérite du bismuth pur et d'un alliage d'antimoine sont étudiées. / Bismuth Fermi surface is composed of one parabolic hole pocket and three equivalent Dirac electrons valleys. The electrons effective mass is low (m* ~ 10-3 me) and very anisotropic (m1 ~ 200 m2). These exceptional electronic properties, combined with a very low carrier density (n=3.10-17 cm-3) and a very large mobility (µ ~ 108 cm2/V/s) imply that bismuth magnetoresistance is very large and very sensitive to the orientation of the magnetic field. During this thesis, we mapped in temperature and magnetic field the angular dependence of transverse magnetoresistance in the three high symmetry planes. Our datas are then fitted by a semi-classical model. This permits to examine the relevance of the semi-classical theory and to extract the mobility tensors components. We find that all mobility tensor components have a temperature dependence close to a T-2, which suggests that the electron-electron interaction is the main diffusion mechanism. At low temperature and high magnetic field, a phase transition induces the loss of the lattice rotational symmetry in angular dependence magnetoresistance measurement. The angular dependence of magneto-Seebeck effect shows the same oscillations as magnetoresistance. Their explanation requires to go beyond the semi-classical model. Finally, magnetic field dependence and anisotropy of thermoelectric power and thermoelectric figure of merit of pure bismuth and a bismuth-antimony alloy are studied.
15

A multiscale model for anisotropic magnetoresistance / Un modèle multi-échelle de la magnétorésistance anisotrope

Bartok, Andras 03 December 2015 (has links)
La magnétorésistance anisotrope (AMR) des matériaux ferromagnétiques est largement utilisée comme le phénomène de base pour la mesure ou la détection de champ magnétique. En raison de la relation entre la configuration en domaines magnétiques et la résistivité macroscopique, l'application d'un champ magnétique externe modifie la résistivité des matériaux ferromagnétiques. Bien que cet effet soit largement utilisé dans des applications industrielles, certains aspects fondamentaux du comportement AMR sont encore assez mal compris. Par exemple, le rôle de la texture cristallographique dans le comportement effectif n'est pas décrit avec précision par les outils classiques de modélisation. En raison de ce lien direct entre la microstructure en domaines et l'effet AMR, les modèles de description de l'effet AMR reposent généralement sur des calculs micromagnétiques. Pour ces calculs, le nombre de degrés de liberté et d'interactions peuvent se multiplier rapidement si on recherche à décrire un comportement macroscopique (cas des polycristaux par exemple).La thèse porte sur la modélisation numérique de l'effet de magnétorésistance anisotrope des matériaux ferromagnétiques. Ce nouvel outil de modélisation 3D peut remédier à cet inconvénient majeur des approches micromagnétiques. Un modèle permettant de décrire les effets de couplage magnéto-élastique en utilisant une approche micro-macro est disponible au laboratoire GeePs. Sur la base des mêmes principes de la modélisation micro-macro, un outil de simulation de l'effet AMR en fonction de la contrainte mécanique et de la texture cristallographique des matériaux a été développé.La stratégie de modélisation est la suivante:Trois échelles de description du comportement sont introduites: le Volume Elémentaire Représentatif (VER) polycristallin (échelle macro), le monocristal ou grain, et enfin le domaine magnétique (échelle micro).Une première étape dite de localisation permet de déterminer le chargement magnéto-mécanique (champ magnétique et contrainte mécanique) à l'échelle d'un grain en fonction du chargement extérieur appliqué. L'introduction de variables internes et des lois d'évolution correspondantes permet de décrire de façon statistique l'évolution de la microstructure en domaines magnétiques sous l'influence de ce chargement local. Toujours à cette échelle, l'utilisation du modèle phénoménologique de Doring permet, pour chaque domaine, de calculer la résistivité en fonction de l'orientation relative entre aimantation locale et courant électrique. Une fois cette résistivité locale connue, une étape dite d'homogénéisation s'appuyant sur le modèle de Bruggeman permet de déterminer la résistivité macroscopique du VER polycristallin. Il est ainsi possible de prédire la variation de la résistivité entre un état initial désaimanté et un état sous chargement magnéto-mécanique quelconque.Les résultats obtenus par cette démarche ont été comparés avec succès à des résultats expérimentaux extraits de la littérature portant sur des polycristaux de Nickel, de Fer pur ou encore de Permalloy.Ensuite des simulations reproduisant les conditions de fonctionnement des capteurs AMR ont été effectuées. Ces simulations permettent de conclure qu'il est possible d'améliorer la sensibilité des capteurs AMR en générant une contrainte résiduelle biaxiale. / The anisotropic magnetoresistance (AMR) of ferromagnetic materials is widely used as the basic phenomenon for measuring or detecting magnetic field. Owing to the relationship between magnetic domain configuration and macroscopic resistivity, the application of an external magnetic field changes the resistivity of ferromagnetic materials. Although this effect is widely used in industrial applications, some basic aspects of AMR behavior are still unsufficiently understood. For example, the role of crystallographic texture is not accurately described by conventional modeling tools. As a consequence of the direct relationship between microstructure and AMR, models for AMR effect are generally based on micromagnetic calculations. For these calculations, the number of degrees of freedom and interactions can grow exponentially when investigating macroscopic behavior (case of polycrystals for example).The thesis deals with the numerical modeling of AMR effect in ferromagnetic materials. This new 3D modeling tool can overcome this major drawback of micromagnetic approaches. A model to describe the effects of magneto-elastic coupling using a micro-macro approach is available at the laboratory GeePs. Based on the same principles of micro-macro modeling, an AMR effect simulation tool has been developed including the effect of mechanical stress and the role of crystallographic texture of materials.The modeling strategy is as follows:Three scales of description of the behavior are introduced: the Representative Volume Element (RVE) of polycrystals (macro scale), the single crystal or grain, and finally the magnetic domain (micro scale).A first step, named localization, determines the magneto-mechanical loading (magnetic field and mechanical stress) within a grain depending on the external applied load. The introduction of internal variables and corresponding evolution laws allow describing in a statistical way the evolution of the magnetic domain microstructure under the influence of the local load. Also at this scale, the use of the phenomenological Doring model allows for each area, to calculate the resistivity as a function of the relative orientation between local magnetization and electric current. Once this local resistivity is known, a so-called homogenization step based on the Bruggeman model is used to determine the macroscopic resistivity of the RVE. It is thus possible to predict the variation in resistivity between an initial demagnetized state and a state under any magneto-mechanical loading.The results obtained by this approach were successfully compared to experimental results from literature on polycrystalline nickel, pure iron or Permalloy.Then simulations reproducing AMR sensors operating conditions were carried out. These simulations lead to the conclusion that it is possible to improve the sensitivity of AMR sensors by introducing an appropriate biaxial residual stress.
16

Mise au point d’un laboratoire sur puce pour la détection de cellules eucaryotes par des capteurs à magnétorésistance géante / Development of a lab on a chip for the detection of eukaryotic cells by giant magnetoresistance sensors

Giraud, Manon 21 November 2019 (has links)
Les tests « in vitro » permettent d’établir près de 70% des diagnostics et leur développement pour une utilisation au plus près du patient apparaît donc comme un enjeu majeur de santé publique. Dans ce contexte, les critères ASSURED (« Affordable, Sensitive, Specific, User-friendly, Rapid and robust, Equipment-free and Deliverable to end-users ») a été défini par l’organisation mondiale de la santé pour que les chercheurs développent des outils de diagnostic dits « Point of Care » utilisables par le plus grand nombre. Avec l’essor de la microfluidique, la gamme des dispositifs possibles s'est élargie et des biocapteurs intégrés ont été développés, transformant le signal biologique d’une reconnaissance d’un biomarqueur par une sonde biologique en un signal optique, électrochimique, mécanique ou encore magnétique. Comme les milieux biologiques sont en grande majorité amagnétiques, les capteurs magnétiques ne sont pas affectés par l’utilisation de matrices biologiques complexes comme peuvent l’être les mesures optiques ou électrochimiques. De plus ces capteurs sont faciles à produire et intégrables dans les puces microfluidiques. Cette thèse a pour objectifs de concevoir un outil de diagnostic in vitro basé sur des capteurs à magnétorésistance géante et de tester ses performances. Cette étude a été réalisée en utilisant une lignée cellulaire de myélome murin. Les cellules sont marquées spécifiquement par des particules magnétiques fonctionnalisées par des anticorps dirigés contre un de leurs antigènes et sont passées dans le canal microfluidique au-dessus des capteurs. Cette méthode de détection dynamique permet de compter les objets magnétiques un par un. La difficulté réside dans la distinction des signaux spécifiques provenant des cellules marquées des signaux faux positifs induits par les billes restant en solution. Deux types de dispositifs ont été conçus dans cette thèse pour lever ce verrou. Le premier possède une couche inerte de séparation de quelques micromètres entre les capteurs GMR et le canal qui permet de supprimer les signaux des billes isolées. Le second dispositif, qui a des capteurs à la fois au-dessus et au-dessous du canal microfluidique, permet une double détection simultanée de chaque objet magnétique. Il est ainsi possible de connaître le nombre de billes qui les marquent et de déterminer s’il s’agit d’un agrégat de billes ou d’un objet biologique. / The « in vitro » tests are requested for the establishment of nearly 70% of diagnoses and their development for on-site detection therefore appears to be a major public health issue. In this context, the ASSURED criterion (« Affordable, Sensitive, Specific, User-friendly, User-friendly, Rapid and robust, Equipment-free and Deliverable to end-users ») has been defined by the World Health Organization to encourage researchers to develop diagnostic tools called « Point of Care » that can be widely used.With the rise of microfluidics, the range of possible devices has broadened and integrated biosensors have been developed, transforming the biological signal from a biomarker recognition by a biological probe into an optical, electrochemical, mechanical or magnetic signal. As biological environments are largely non-magnetic, magnetic sensors are not affected by the use of complex biological matrices as are optical or electrochemical measurements. In addition, these sensors are easy to produce and can be integrated into microfluidic chips. The objectives of this thesis are to design a diagnostic tool in vitro based on giant magnetoresistance sensors and to test its performance. Its development was carried out using a murine myeloma cell line. The cells are specifically labeled by magnetic particles functionalized by antibodies directed against one of their antigens and flown in the microfluidic channel above the sensors. This dynamic detection method allows magnetic objects to be counted one by one. The challenge is to distinguish the signals coming from the labeled cells from those of the beads remaining in solution. In order to address this problem, two labs on chips are developed in this thesis. In a first device, an inner layer of a few micrometers separates the sensors from the channel which allows to suppress the signals of the isolated beads. The second device has sensors both above and below the microfluidic channel and can measure the number of beads corresponding to each doubly detected object which can thus be identified (aggregates or biological objects).
17

Microscopie à émission d’électrons balistiques : du magnétotransport d’électrons chauds à l’imagerie magnétique / Ballistic electron emission microscopy : from hot electron magnetotransport to magnetic imaging

Hervé, Marie 12 July 2013 (has links)
Au cours de ces travaux de thèse, nous avons étudié par microscopie magnétique à émission d’électrons balistiques (BEMM) les propriétés de magnétotransport d’électrons chauds de la vanne de spin Fe/Au/Fe épitaxiée sur GaAs(001). Dans ces expériences, la pointe d’un microscope à effet tunnel (STM) injecte localement un courant d’électrons chauds à la surface de la vanne de spin. La mesure sous champ magnétique du courant d’électrons balistiques collecté à l’arrière de l’échantillon donne accès aux propriétés locales de magnétoconductance de l’échantillon. Nous avons dans un premier temps étudié les propriétés de magnétotransport de vannes de spin planaires. Les mesures BEMM démontrent un magnétocourant d’électrons chauds pouvant atteindre 500 % à température ambiante. Ces forts effets de magnétoconductance ne sont que très faiblement dépendants des épaisseurs des électrodes de fer et ne peuvent donc être dus à l’asymétrie en spin de la longueur d’atténuation des électrons chauds dans les couches de fer. Dans cette structure épitaxiée, la polarisation en spin du faisceau d’électrons chauds s’acquiert principalement aux interfaces via des effets de structure électronique. L’électron traversant les couches minces métalliques se propage comme un état de Bloch. Sa transmission aux différentes interfaces se fait en conservant d’une part la composante transverse k║ du vecteur d’onde électronique, et d’autre part, la symétrie de la fonction d’onde. Au-dessus de la barrière Schottky, les électrons chauds sont collectés dans la vallée Г du GaAs se projetant à l’interface dans la direction k║=0. Dans cette direction k║=0, la conservation de la symétrie de la fonction d’onde à l’interface Fe/Au conduit au filtrage des états de Bloch de symétrie Δ1 du fer. Ces états de symétrie Δ1, totalement polarisés en spin, sont responsables des forts magnétocourants d’électrons chauds observés. Cette analyse est confirmée expérimentalement par l’observation d’une corrélation entre amplitude du magnétocourant et masse effective du substrat semiconducteur. En augmentant la masse effective du semiconducteur, on ouvre le collimateur filtrant le courant d’électrons chauds autour de la direction k║=0, et le magnétocourant diminue sans modifier la vanne de spin. Dans un second temps, tirant partie de la résolution latérale du microscope et de sa sensibilité au magnétisme, des microstructures de fer préparées sous ultra-vide par évaporation à travers un masque (méthode du nanostencil) ont été étudiées. Dans ces structures, la modulation du courant collecté par la structure locale en domaines magnétiques a permis la réalisation d’images magnétiques avec une haute résolution spatiale. Les contrastes observés sur ces microstructures sont en excellent accord avec les images BEMM calculées à partir de simulations micromagnétiques ouvrant la voie à une microscopie magnétique quantitative à forte sensibilité et résolution latérale nanométrique. / During this thesis work, we studied by ballistic electron magnetic microscopy (BEMM) the hot electron magnetotransport properties of epitaxial Fe/Au/Fe/GaAs(001) heterostructures. In these experiments, hot electrons are injected from an STM tip through the metallic base. The measurement of the ballistic electron current collected at the back of the substrate under magnetic field gives access to the local magnetoconductance properties of the sample. The first part of this work consists in the study of a planar heterostructures. BEMM measurements on epitaxial Fe/Au/Fe/GaAs(001) samples demonstrate hot electron magnetocurrent as high as 500% at room temperature. This high magnetocurrent value is observed to be almost independent of the Fe layers thickness, and thus can not be explained by the spin asymmetry of the electron attenuation length in the iron layers. In this epitaxial heterostructure, the hot electron beam is mainly spin-polarized at the interfaces due to band structure effects. In the metallic thin films, electrons propagate as Bloch states. The electron wave function transmission at the interfaces should satisfy two selection rules: the transverse momentum (k║) of the electron wave vector and the symmetry of the electron wave function should be conserved. Above the Schottky barrier height, hot-electrons are collected in the Г valley of GaAs selecting thus only electrons with a transverse momentum (k║) close to zero. Among these k|| ≈ 0 states, conservation of the electron wave-function symmetry at the Fe/Au epitaxial interfaces additionally selects electrons with the Δ1 symmetry. These Δ1 states are fully spin-polarized and are responsible for the observed high magnetocurrent in these heterostructures. This analysis is experimentally confirmed by the observation of a correlation between the magnetocurrent value and the semiconductor effective mass. By increasing the semiconductor effective mass, we open the collimator which filters the electronic states around k║=0 and the magnetocurrent value decreases. To take advantage of the lateral resolution of the microscope and of its high sensitivity to magnetism, the second part of this work was devoted to the study of sub-micrometric iron structures prepared under UHV by evaporation through a nanostencil. In these structures, the modulation of the collected current by the local magnetic domain structure in the Fe dots allows magnetic imaging with a high spatial resolution. The experimental magnetocontrasts observed on these sub-micrometric Fe dots are in excellent agreement with BEMM current maps calculated from micromagnetic simulation results. This opens the way to a quantitative magnetic microscopy with high contrast and nanometric lateral resolution.
18

Transport électronique polarisé en spin dans les contacts atomiques de fer

Autès, Gabriel 12 December 2008 (has links) (PDF)
Cette thèse est consacrée à l'étude théorique du transport électronique dans les contacts atomiques magnétiques. L'objectif principal est d'expliquer la magnétorésistance anisotrope géante mesurée expérimentalement dans les jonctions à cassure de fer. Dans ce but, on a développé une méthode de calcul de la conductance des nanostructures magnétiques.<br />Le calcul est effectué en deux étapes. Dans un premier temps, la structure électronique du contact est déterminée de manière autocohérente dans une base d'orbitales atomiques spd à l'aide d'un modèle de liaisons fortes étendu au magnétisme. Les propriétés magnétiques sont décrites à l'échelle atomique par un modèle d'interaction inter-électronique. Deux modèles d'interactions sont comparés : un modèle simple de type Stoner et un modèle plus complet de type Hartree-Fock développé pour reproduire les effets de polarisation orbitale susceptibles d'apparaître au niveau du contact. En effet, dans les nanostructures unidimensionnelles, on observe une levée du blocage du moment orbital qui existe dans les cristaux cubiques en volume. Pour permettre la description de l'anisotropie magnétique du système, on prend aussi en compte le magnétisme non-colinéaire et le couplage spin-orbite.<br />Dans un second temps, les propriétés de transport électroniques du système sont déterminées dans le formalisme de Landauer. Dans cette approche, on considère que le transport est cohérent et élastique. Cette approximation est valide quand étudie un conducteur de taille atomique à basse température sous de faibles tensions. La conductance est alors directement proportionnelle à la probabilité de transmission des électrons à travers le système. Cette transmission est calculée à partir de la fonction de Green du système. <br />Cette méthode de calcul est appliquée à l'étude de la magnétorésistance anisotrope des contacts de fer. Plusieurs géométries de contact, allant du fil monoatomique parfait aux systèmes réalistes, sont comparées. Les résultats révèlent le rôle prépondérant joué par la géométrie et par la polarisation orbitale. Pour que l'anisotropie magnétique soit aussi élevée que dans les expériences, il est nécessaire que l'atome de contact soit dans une configuration de fil monoatomique. Les effets de polarisation orbitale permettent d'expliquer les deux plateaux de conductance mesurés expérimentalement. Ils sont liés à l'existence de deux états magnétiques métastables qui différent par la direction du moment orbital sur l'atome de contact.
19

Synthèse et caractérisation de pérovskites doubles magnétorésistives dérivées de Sr2FeMoO6

JURCA, Ciprian Bogdan 20 December 2004 (has links) (PDF)
Cette thèse concerne la synthèse et l'étude des propriétés physico-chimiques des pérovskites doubles Sr2FeMoO6, Sr2FexMo2-xO6 (x = 0,9-1,33) et Sr2FeCrxMo1-xO6 (x = 0,1-0,25). Pour Sr2FeMoO6 les conditions de synthèse à l'état solide influencent la microstructure des échantillons et l'ordre Fe/Mo. Des frittages successifs avec des broyages intermédiaires entraînent ainsi une augmentation de l'aimantation à saturation (3,8 µB) qui s'approche de la valeur idéale (4 µB) et améliorent la magnétorésistance en champ faible (LFMR) de 1,58 ± 0,14 % à 2,74 ± 0,01 % (T = 300 K, H = 1 kOe) en raison des modifications microstructurales. Les valeurs des moments magnétiques effectifs montrent la présence de valences mixtes: FeII/MoVI et FeIII/MoV. Les compositions Sr2FexMo2-xO6 (quadratiques ou cubiques pour x > 1,2) acceptent un plus grand excès de fer que de molybdène. L'ordre Fe/Mo diminue quand x s'écarte de 1 et tend vers une valeur d'équilibre après un grand nombre de traitements de frittage pour un x donné. La Tc augmente avec x (couplages Fe-Fe plus forts que les couplages Fe-Mo), tandis que l'aimantation à saturation est maximum pour x = 1. La résistivité augmente avec x (les électrons délocalisés proviennent du molybdène), elle dépend davantage de la composition chimique que de la microstructure. La magnétorésistance est maximum pour x = 1; pour x = 1,33 le matériau cesse d'être un demi-métal. Pour la série Sr2FeCrxMo1-xO6 l'augmentation du contenu en chrome détermine la diminution de l'ordre des cations sur les sites octaédriques et par conséquent une baisse de Tc, d'aimantation et de magnétorésistance.
20

Transport dépendant du spin et couplage d'échange : de la jonction tunnel au capteur magnétique intégré

Malinowski, Grégory 20 December 2004 (has links) (PDF)
Dans une première partie, les propriétés cristallographiques et magnétiques de couches minces X/IrMn et X/IrMn/Y (X,Y= Co et/ou Py) sont présentées. Le magnétisme est expliqué à l'aide de modèles micromagnétiques. La différence de couplage d'échange aux interfaces X/IrMn et IrMn/Y est indépendante de la microstructure et uniquement liée à l'ordre d'empilement des couches. Il est démontré que déposer une couche antiferromagnétique sur une couche ferromagnétique est totalement différent d'un point de vue magnétique de l'opération inverse. Dans une seconde partie, la bicouche IrMn/Co est utilisée comme couche de détection dans une jonction tunnel magnétique pour réaliser un capteur de champ magnétique linéaire et réversible dans la gamme –50 et 50 Oe. Un choix judicieux des paramètres de la jonction tunnel a permis de rendre la sensibilité du capteur indépendante de la température. Sur cette base, un démonstrateur de capteur magnétique avec son électronique de traitement est réalisé.

Page generated in 0.0529 seconds