1

Estudo comparativo do desempenho de diferentes eletrodos ventriculares no seguimento a médio prazo pós-implante de marcapasso

Sales, Marcela da Cunha January 2008 (has links)
INTRODUÇÃO: O número de implantes de marcapassos vem crescendo consideravelmente e também a utilização de eletrodos de fixação ativa eluídos com corticóides. No entanto, dados prospectivos do desempenho destes eletrodos a médio e longo prazo são, ainda, bastante restritos. OBJETIVOS: O objetivo principal deste estudo é determinar a estabilidade dos parâmetros elétricos ao longo do tempo (limiares de estimulação, medidas de sensibilidade e de impedância) para dois eletrodos ventriculares diferentes, ambos eluídos com corticóide, sendo um de fixação ativa e um de fixação passiva e compará-los entre si. Também queremos determinar o momento em que há estabilização destas medidas. PACIENTES E MÉTODOS: Pacientes com indicação de implante de marcapasso foram alocados em dois grupos: Grupo A – implante de eletrodo ventricular de fixação ativa (Setrox S-Biotronik) e Grupo P – implante de eletrodo ventricular de fixação passiva (Selox ST-Biotronik), ambos eluídos com corticóides. Foram realizadas medidas de parâmetros elétricos durante o implante, 48h, 15d, 30d, 60d, 90 e 180d: medidas de sensibilidade, impedância e de limiares de estimulação com diferentes larguras de pulso (0,2, 0,4 e 0,5ms). RESULTADOS: Foram incluídos, de forma não randomizada, 55 pacientes, com idade média de 72 ± 9 anos, sendo 31(56,36%) do sexo masculino. A principal indicação de implante foi Bloqueio Átrio-Ventricular de 3º grau (31 pacientes - 56,36%). Características clínicas basais foram iguais nos dois grupos. Análise das medidas de parâmetros elétricos: Sensibilidade ventricular (onda R): Não houve diferença entre as medidas feitas nos diferentes tempos em cada grupo (grupo A, P=0,314 e grupo P, P=0,327 entre os diversos tempos). Também não houve diferença entre as curvas dos dois grupos entre si (P=0,78 para as comparações entre as curvas). Medidas de impedância do eletrodo ventricular: Nos dois grupos (A e P) houve diminuição significativa das impedâncias em 48h e 15d (P<0,0001 e P=0,007 respectivamente). A partir de 15 dias, as curvas das impedâncias dos dois grupos estabilizaram, não havendo mais diferença significativa entre os valores médios. Na comparação entre os valores de impedância das duas curvas, o grupo P teve valores significativamente mais elevados em todos os momentos em que houve medição (P=0,01). Medidas dos limiares de estimulação ventricular: os grupos A e P tiveram achados semelhantes para as medidas com as diferentes larguras de pulso: em 48hs houve uma leve tendência de queda do limiar sem significância estatística, seguida de uma elevação importante (com significância estatística). A partir dos 15 dias, houve estabilização dos limiares de estimulação para os dois grupos, sem mudanças significativas até o final do acompanhamento. Não houve diferença na comparação das curvas dos dois grupos. CONCLUSÕES: Os eletrodos testados de fixação ativa e passiva eluídos com corticóides apresentaram parâmetros de sensibilidade e limiares de estimulação semelhantes entre si, enquanto que o eletrodo passivo apresentou-se com impedâncias maiores em todas as medidas. Para os dois eletrodos houve alterações significativas de limiares e impedância até 15 dias pós-implante seguido de estabilização até o final do período. Estes achados podem ter implicações na seleção do eletrodo, no agendamento das revisões e na programação do marcapasso.
2

Estudo comparativo do desempenho de diferentes eletrodos ventriculares no seguimento a médio prazo pós-implante de marcapasso

Sales, Marcela da Cunha January 2008 (has links)
INTRODUÇÃO: O número de implantes de marcapassos vem crescendo consideravelmente e também a utilização de eletrodos de fixação ativa eluídos com corticóides. No entanto, dados prospectivos do desempenho destes eletrodos a médio e longo prazo são, ainda, bastante restritos. OBJETIVOS: O objetivo principal deste estudo é determinar a estabilidade dos parâmetros elétricos ao longo do tempo (limiares de estimulação, medidas de sensibilidade e de impedância) para dois eletrodos ventriculares diferentes, ambos eluídos com corticóide, sendo um de fixação ativa e um de fixação passiva e compará-los entre si. Também queremos determinar o momento em que há estabilização destas medidas. PACIENTES E MÉTODOS: Pacientes com indicação de implante de marcapasso foram alocados em dois grupos: Grupo A – implante de eletrodo ventricular de fixação ativa (Setrox S-Biotronik) e Grupo P – implante de eletrodo ventricular de fixação passiva (Selox ST-Biotronik), ambos eluídos com corticóides. Foram realizadas medidas de parâmetros elétricos durante o implante, 48h, 15d, 30d, 60d, 90 e 180d: medidas de sensibilidade, impedância e de limiares de estimulação com diferentes larguras de pulso (0,2, 0,4 e 0,5ms). RESULTADOS: Foram incluídos, de forma não randomizada, 55 pacientes, com idade média de 72 ± 9 anos, sendo 31(56,36%) do sexo masculino. A principal indicação de implante foi Bloqueio Átrio-Ventricular de 3º grau (31 pacientes - 56,36%). Características clínicas basais foram iguais nos dois grupos. Análise das medidas de parâmetros elétricos: Sensibilidade ventricular (onda R): Não houve diferença entre as medidas feitas nos diferentes tempos em cada grupo (grupo A, P=0,314 e grupo P, P=0,327 entre os diversos tempos). Também não houve diferença entre as curvas dos dois grupos entre si (P=0,78 para as comparações entre as curvas). Medidas de impedância do eletrodo ventricular: Nos dois grupos (A e P) houve diminuição significativa das impedâncias em 48h e 15d (P<0,0001 e P=0,007 respectivamente). A partir de 15 dias, as curvas das impedâncias dos dois grupos estabilizaram, não havendo mais diferença significativa entre os valores médios. Na comparação entre os valores de impedância das duas curvas, o grupo P teve valores significativamente mais elevados em todos os momentos em que houve medição (P=0,01). Medidas dos limiares de estimulação ventricular: os grupos A e P tiveram achados semelhantes para as medidas com as diferentes larguras de pulso: em 48hs houve uma leve tendência de queda do limiar sem significância estatística, seguida de uma elevação importante (com significância estatística). A partir dos 15 dias, houve estabilização dos limiares de estimulação para os dois grupos, sem mudanças significativas até o final do acompanhamento. Não houve diferença na comparação das curvas dos dois grupos. CONCLUSÕES: Os eletrodos testados de fixação ativa e passiva eluídos com corticóides apresentaram parâmetros de sensibilidade e limiares de estimulação semelhantes entre si, enquanto que o eletrodo passivo apresentou-se com impedâncias maiores em todas as medidas. Para os dois eletrodos houve alterações significativas de limiares e impedância até 15 dias pós-implante seguido de estabilização até o final do período. Estes achados podem ter implicações na seleção do eletrodo, no agendamento das revisões e na programação do marcapasso.
3

Estudo comparativo do desempenho de diferentes eletrodos ventriculares no seguimento a médio prazo pós-implante de marcapasso

Sales, Marcela da Cunha January 2008 (has links)
INTRODUÇÃO: O número de implantes de marcapassos vem crescendo consideravelmente e também a utilização de eletrodos de fixação ativa eluídos com corticóides. No entanto, dados prospectivos do desempenho destes eletrodos a médio e longo prazo são, ainda, bastante restritos. OBJETIVOS: O objetivo principal deste estudo é determinar a estabilidade dos parâmetros elétricos ao longo do tempo (limiares de estimulação, medidas de sensibilidade e de impedância) para dois eletrodos ventriculares diferentes, ambos eluídos com corticóide, sendo um de fixação ativa e um de fixação passiva e compará-los entre si. Também queremos determinar o momento em que há estabilização destas medidas. PACIENTES E MÉTODOS: Pacientes com indicação de implante de marcapasso foram alocados em dois grupos: Grupo A – implante de eletrodo ventricular de fixação ativa (Setrox S-Biotronik) e Grupo P – implante de eletrodo ventricular de fixação passiva (Selox ST-Biotronik), ambos eluídos com corticóides. Foram realizadas medidas de parâmetros elétricos durante o implante, 48h, 15d, 30d, 60d, 90 e 180d: medidas de sensibilidade, impedância e de limiares de estimulação com diferentes larguras de pulso (0,2, 0,4 e 0,5ms). RESULTADOS: Foram incluídos, de forma não randomizada, 55 pacientes, com idade média de 72 ± 9 anos, sendo 31(56,36%) do sexo masculino. A principal indicação de implante foi Bloqueio Átrio-Ventricular de 3º grau (31 pacientes - 56,36%). Características clínicas basais foram iguais nos dois grupos. Análise das medidas de parâmetros elétricos: Sensibilidade ventricular (onda R): Não houve diferença entre as medidas feitas nos diferentes tempos em cada grupo (grupo A, P=0,314 e grupo P, P=0,327 entre os diversos tempos). Também não houve diferença entre as curvas dos dois grupos entre si (P=0,78 para as comparações entre as curvas). Medidas de impedância do eletrodo ventricular: Nos dois grupos (A e P) houve diminuição significativa das impedâncias em 48h e 15d (P<0,0001 e P=0,007 respectivamente). A partir de 15 dias, as curvas das impedâncias dos dois grupos estabilizaram, não havendo mais diferença significativa entre os valores médios. Na comparação entre os valores de impedância das duas curvas, o grupo P teve valores significativamente mais elevados em todos os momentos em que houve medição (P=0,01). Medidas dos limiares de estimulação ventricular: os grupos A e P tiveram achados semelhantes para as medidas com as diferentes larguras de pulso: em 48hs houve uma leve tendência de queda do limiar sem significância estatística, seguida de uma elevação importante (com significância estatística). A partir dos 15 dias, houve estabilização dos limiares de estimulação para os dois grupos, sem mudanças significativas até o final do acompanhamento. Não houve diferença na comparação das curvas dos dois grupos. CONCLUSÕES: Os eletrodos testados de fixação ativa e passiva eluídos com corticóides apresentaram parâmetros de sensibilidade e limiares de estimulação semelhantes entre si, enquanto que o eletrodo passivo apresentou-se com impedâncias maiores em todas as medidas. Para os dois eletrodos houve alterações significativas de limiares e impedância até 15 dias pós-implante seguido de estabilização até o final do período. Estes achados podem ter implicações na seleção do eletrodo, no agendamento das revisões e na programação do marcapasso.
4

Avaliação de variaveis preditoras de melhora clinica aguda na terapia de ressincronização cardiaca artificial

Souza, Fernando Sergio Oliva de 19 November 2003 (has links)
Orientador: Reinaldo Wilson Vieira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-03T21:46:14Z (GMT). No. of bitstreams: 1 Souza_FernandoSergioOlivade_M.pdf: 677896 bytes, checksum: 6c662640c5d0a34ad3f0be6231947de0 (MD5) Previous issue date: 2003 / Resumo: A estimulação biventricular vem apresentando bons resultados, no tratamento da insuficiência cardíaca congestiva(ICC) refratária, em portadores de cardiomiopatia dilatada(CMD) com distúrbios de condução intraventricular. Um dos pontos centrais de pesquisas atualmente, é identificar os pacientes que mais irão se beneficiar do tratamento. OBJETIVO: avaliação de variáveis hemodinâmicas, clínicas e eletrocardiográficas como preditores de obtenção de maior beneficio a curto prazo em portadores de ICC, previamente selecionados, submetidos a implante de marcapasso biventricular. MÉTODOS:Foram estudados 47 pacientes submetidos a estimulação biventricular no período de Dezembro de 1999 a Março de 2002 ,19 de origem isquêmica(40,4%), 17 de origem idiopática(36,2%) e 11 de origem chagásica(23,4%), sendo submetidos a exames clínicos e de propedêutica armada, que constavam na avaliação da classe funcional(CF) da ICC, teste de caminhada de seis minutos, ecodopplercardiograma bidimensional (para avaliação da insuficiência mitral e fração de ejeção) e eletrocardiograma de superfície (avaliação da duração do complexo QRS , em milisegundos, e padrão de bloqueio de ramo), um dia antes da operação e novamente no 10o dia de pós-operatório. RESULTADOS: Apenas uma paciente não obteve melhora clínica com o tratamento. O grupo de pacientes em CF IV apresentou maior incremento na distância percorrida no teste de caminhada. CONCLUSÃO: A CF IV de pré-operatório se mostrou preditor de maior benefício com a estimulação biventricular a curto prazo. A etiologia da cardiomiopatia dilatada, o grau de insuficiência mitral, o grau estreitamento do QRS e o tipo de bloqueio de ramo não influenciaram nos resultados a curto prazo no grupo de pacientes estudados / Abstract: Biventricular pacing has present good results in treatment of congestive cardiac heart failure in patients with dilated miocardyopathy and intraventricular conduction disturbance. One of the goals of research in these days is to identify group of patients that will have more benefit with the treatment. OBJECTIVES: Evaluate hemodynamics, clinical and eletrocardiographics variables as predictors, in short time, in patients with congestive heart failure,previously selected, who most get more benefit with biventricular pacing. METHOD: From December 1999 to March 2002, 47 patients submited to biventricular pacing were evaluated.. The etiology was ischemic in 19(40.4%), idiophatic in 17(36.2%) and Chagas disease in 11(23.4%). Based on clinical examination , six minute walking test, echocardiogram, patients were evaluated one day before and 10 days after the procedure. RESULTS: Only one patient didn't have clinical improvement with the treatment , the group class IV got more improvement in distance walked in six minute walk test than class III. CONCLUSION: The functional class IV was considered predictors for best benefit with biventricular pacing in short time. Etiology of myocardiopathy, degree of mitral insufficience, shortenth of QRS and type of bundle branch block had no influence in this group of patients / Mestrado / Cirurgia / Mestre em Cirurgia
5

bioimpedância elétrica : análise de interferência em dispositivos cardíacos eletrônicos implantáveis

Garlini, Luiza Matos January 2017 (has links)
Resumo não disponível.
6

Filtro OTA-C de baixa potência aplicado a um detector de atividade cardíaca

Spiller, Luís Henrique January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2013-07-16T02:26:47Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta um sistema de detecção de atividade cardíaca para marca-passos baseado em estruturas de filtragem contínua OTA-C. A natureza da aplicação implica na minimização do consumo de potência do circuito para prolongar a vida útil das baterias que o alimentam. O filtro proposto usa transcondutores compostos por transistores MOS operando no regime de inversão fraca, onde a razão transcondutância por corrente de polarização é maximizada. O transcondutor é um par diferencial com degeneração de fonte para aumento da faixa de linearidade. Um circuito de realimentação de modo comum assegura a estabilização da tensão DC da saída diferencial do transcondutor em um valor pré-determinado. O filtro emprega estruturas completamente diferenciais e é dividido em blocos de segunda ordem para implementar a função de transferência desejada. Os controles da freqüência central do filtro e do ganho global são obtidos através de ajuste da corrente de polarização. Um comparador foi projetado para decidir se a saída do filtro corresponde ao evento de entrada monitorado. A performance do circuito final é verificada por simulação usando parâmetros fornecidos pelo programa MOSIS para a tecnologia AMIS 1,5µm. Os resultados demonstram a operacionalidade do filtro, mesmo quando são incluídos parâmetros tecnológicos associados ao descasamento dos transistores.
7

bioimpedância elétrica : análise de interferência em dispositivos cardíacos eletrônicos implantáveis

Garlini, Luiza Matos January 2017 (has links)
Resumo não disponível.
8

bioimpedância elétrica : análise de interferência em dispositivos cardíacos eletrônicos implantáveis

Garlini, Luiza Matos January 2017 (has links)
Resumo não disponível.
9

Variação do debito cardiaco na estimulação artificial em ponta do ventriculo esquerdo, ponta do ventriculo direito e biventricular : estudo experimental em porcos

Mortati, Nicola Luciano 08 June 2003 (has links)
Orientador: Reinaldo Wilson Vieira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T17:09:13Z (GMT). No. of bitstreams: 1 Mortati_NicolaLuciano_M.pdf: 1245542 bytes, checksum: ba7efd360a113daf1b0fe25e8ea1a526 (MD5) Previous issue date: 2003 / Resumo: Os modelos experimentais permitem o estudo da atuação do marcapasso artificial em fenômenos fisiológicos do coração e a sua correlação com a prática clínica. Os objetivos deste trabalho foram: 1) padronizar a técnica de obtenção de B.A.V.T. experimental e 2) estudar o comportamento do débito cardíaco com o coração em ritmo sinusal, em B.A.V.T. e em estimulação cardíaca epimiocárdica na ponta do V.D., na ponta do V.E. e na biventricular. A par disso estudamos também a variação: dos limiares de estimulação, da amplitude da onda R, da impedância elétrica entre o eletrodo e o miocárdio e da largura do complexo QRS.Utilizamos suínos com o coração supostamente normal para obter B.A.V.T. experimental pela técnica de toracotomia com esternotomia longitudinal, sem atriotomia, e necrose química do sistema de condução por injeção local de formaldeído a 40% (quarenta por cento). O débito cardíaco foi medido por termodiluição. Os registros de E.C.G. de superfície foram feitos nas derivações D1, D2 e D3 com equipamento DMS1000 (Biotronik). Os cabos eletrodos epimiocárdicos utilizados foram do modelo ELC-35 (Biotronik Gmbh). A estimulação foi feita com equipamento ERA300 (Biotronik) em modo V.O.O. com 5 (cinco) V de amplitude e 1 (um) ms de duração com freqüência de estimulação semelhante à encontrada quando o coração estava em ritmo sinusal e o tórax aberto. O B.A.V.T. foi obtido em todos os animais estudados. Nesta situação o D.C. sofre queda acentuada e retorna aos níveis do ritmo sinusal com qualquer dos modos de estimulação utilizados. Os limiares de estimulação e a amplitude de onda R medidos na ponta do V.D. e na ponta do V.E. são estatisticamente iguais; contudo, a impedância elétrica na ponta do V.E. é estatisticamente maior que na ponta do V.D.. Na estimulação elétrica artificial na ponta do V.E. e biventricular (BV2) com eletrodo negativo na ponta do V.E. observa-se maior encurtamento da largura do complexo QRS / Abstract: The experimental models admit the study of the artificial pacemakers in heart physiological phenomena and its correlation with the clinical practice. The purposes of this work were to pattern the technique of production of complete experimental AV block and to study the variation of the cardiac output in the sinus rhythm, in the AV block and with cardiac pacing in the apex of the RV, in the apex of the LV and in the biventricular pacing. At the same time, we also studied the variation of the stimulation threshold, the R wave amplitude, the electrical impedance between the electrode and the cardiac muscle and the variation of the length of the QRS complex. They were studied swine, with supposedly normal heart, to get complete experimental AV block by using thoracotomy with longitudinal externotomy without atriotomy by chemical necrosis of the conduction system by a 40 % formaldehyde solution injection. The cardiac output was measured by a thermo-dilution technique. The superficial E.K.G. registers were made in deviations D1, D2 and D3 with DMS1000 (Biotronik) device. The epicardial electrodes were model ELC-35 (Biotronik Gmbh). The stimulation was made with ERA300 (Biotronik) device in the VOO mode with 5 V of amplitude and 1 ms of length and the stimulation frequency was similar to that one found in the sinus rhythm in the open thorax. It was obtained complete AV block in all of the studied animals. The C.O., in this situation, was reduced a lot and it returned to the sinus rhythm level with all the stimulation modes. The threshold and R amplitude in apex of the RV and the apex of the LV were statistically equals; however, the electrical impedance of the LV was statistically higher than that one in the apex of the RV. It was observed a greater shortening of the length of the QRS complex with in the electrical artificial stimulation in the apex of LV and in the biventricular stimulation with negative electrodes in the apex of the LV and positive electrodes in the apex of the RV / Mestrado / Cirurgia / Mestre em Cirurgia
10

Avaliação da qualidade de vida relacionada à saúde de pacientes portadores de marca-passo / Evaluation of the health-related quality of life of patients with pacemakers

Gonçalo, Sumaya dos Santos 28 June 2018 (has links)
Introdução: Pretende-se com a estimulação cardíaca artificial promover melhor qualidade de vida a portadores de complicações cardíacas graves, porém, a falta de conhecimento dos pacientes e o despreparo dos profissionais de saúde podem influenciar nos hábitos de vida e no surgimento de possíveis complicações. Objetivo: Avaliar a qualidade de vida relacionada à saúde (QVRS) de pacientes portadores de marca-passo (MCP) e explorar as associações entre QVRS e variáveis sociodemográficas, clínicas e sintomas de ansiedade e depressão. Método: Estudo observacional analítico, de corte transversal, realizado em hospital universitário do interior paulista. Uma amostra consecutiva e não probabilística foi constituída de pacientes de ambos os sexos, maiores de 18 anos, portadores de MCP há pelo menos um mês. Para a avaliação da QVRS, foi utilizado um instrumento genérico (SF-36) e um específico (AQUAREL). Para investigarmos a associação da QVRS com o sexo e o estado civil, utilizamos o teste t de Student. Para QVRS com a idade, o tempo de implante de MCP e os sintomas de ansiedade e de depressão, utilizamos o teste de Correlação de Pearson. O nível de significância foi de 0,05. Resultados: Participaram 88 pacientes, maioria do sexo masculino e com companheiro. Sua média de idade foi 64,3 (DP=13,0). Utilizando o SF-36, o domínio que apresentou maior média foi \"Aspectos Sociais\", e a menor, \"Aspectos Físicos\". Utilizando o AQUAREL, o domínio de maior média foi \"Arritmia\", e o de menor, \"Dispneia\". Quanto às associações, as mulheres apresentaram menores médias nos domínios \"Capacidade Funcional\", \"Estado Geral de Saúde\", \"Vitalidade\", \"Saúde Mental\" e \"Componente Mental\" do SF-36, bem como nos domínios \"Arritmia\" e \"Dispneia\" do AQUAREL, com significância estatística. Os pacientes sem companheiro apresentaram menores médias nos domínios \"Capacidade Funcional\", \"Vitalidade\" e \"Aspectos Sociais\" do SF-36, e nos domínios \"Arritmia\" e \"Dispneia\" AQUAREL, com significância estatística. Quanto à idade, as correlações foram significativas com os domínios \"Capacidade Funcional\" e \"Aspectos Físicos\" do SF-36, com baixa força de correlação. Quanto ao tempo de implante de MCP, as correlações foram significativas com o domínio \"Capacidade Funcional\" do SF-36 e com o domínio \"Arritmia\" do AQUAREL, com baixa força da correlação. Quanto à correlação da QVRS com os sintomas de ansiedade, foi significativa com os oito domínios do SF-36 e com os dois componentes, negativa, de forte magnitude no domínio \"Saúde Mental\" e no Componente Mental, e moderada em outros seis domínios. A correlação da ansiedade com os três domínios do AQUAREL foi negativa, significativa e de moderada magnitude. Quanto à correlação da depressão com a QVRS, foi significativa com os oito domínios do SF-36 e com os dois componentes, negativa, de forte magnitude no domínio \"Saúde Mental\" e moderada magnitude em quatro domínios e no Componente Mental. A correlação da depressão com os três domínios do AQUAREL foi negativa, significativa e de moderada magnitude. Conclusão: Os pacientes apresentaram pior QVRS nos domínios que avaliaram o quanto as condições físicas interferem no dia-a-dia. As mulheres, os pacientes sem companheiro e com maior sintomatologia de ansiedade e depressão apresentaram pior avaliação. / Introduction: Artificial cardiac stimulation aims to offer a better quality of life to those with severe cardiac problems. However, the lack of knowledge of the patients and the lack of preparation of health professionals can influence the life habits and lead to the surfacing of potential complications. Objective: Evaluating the health-related quality of life (HRQOL) of patients who have pacemakers (PM) and explore the associations between HRQOL and sociodemographic and clinical variables and symptoms of anxiety and depression. Method: Observational, analytical and cross-sectional study, conducted in a teaching hospital in the countryside of the state of São Paulo. A consecutive non-probabilistic sample was created including male and female patients above 18 years old who had had an MP for at least a month. To evaluate their HRQOL, a generic (SF-36) and a specific (AQUAREL) instruments were used. To investigate the association of HRQOL with sex and marital status, Student\'s t-test was used, and to analyze its relationship to age, time since MP implantation, and depression and anxiety symptoms, Pearson\'s Correlation Coefficient was used. The significance level was 0.05. Results: 88 patients participated, most were male and had partners. Age average was 64.3 (SD=13.0). The SF-36 domain with the highest average was \"Social Aspects\", and the one with the lowest, \"Physical Aspects\". The greatest average among AQUAREL domains was \"Arrythmia\", and the lowest, \"Dyspnea\". As to associations, women presented lower averages in the domains \"Functional Capabilities\", \"General Health State\", \"Vitality\", \"Mental Health\" and \"Mental Component\" of the SF-36. The same was true for AQUAREL domains \"Arrythmia\" and \"Dyspnea\", all these correlations statistically significant. Patients with no partners had statistically significant lower averages in the SF-36 domains \"Functional Capabilities\", \"Vitality\" and \"Social Aspects\", and in the AQUAREL domains \"Arrythmia\" and \"Dyspnea\". As to their age, correlations were significant with the SF-36 domains \"Functional Capabilities\" and \"Physical Aspects\", with low-strength correlations. As to the time passed since the PM implantation, low-strength correlations were significant in the SF-36 domain \"Functional Capabilities\" and the AQUAREL domain \"Arrythmia\". As to the correlation of HRQOL to anxiety symptoms, it was significant for the eight SF-36 domains and its two components, being negative and strong in the \"Mental Health\" domain and in the Mental Component, and moderate in the other domains. Anxiety was negatively, significantly and moderately correlated to all three AQUAREL domains. The correlation of depression to HRQOL, was significant in the eight SF-36 domains and its two components, negative and strong in the \"Mental Health\" domain and moderately strong in four Mental Component domains. Depression was negatively, significantly and moderately correlated to all three AQUAREL domains. Conclusion: Patients had lower HRQOL in the domains which evaluated how do physical conditions interfere in their daily lives. Women, patients with no partners and more anxiety and depression symptoms had worse results in the evaluation.