Spelling suggestions: "subject:"marcapasso artificial"" "subject:"marcapasso aartificial""
11 |
Qualidade de vida em pacientes portadores de marca-passo cardíaco /Barros, Rubens Tofano de. January 2013 (has links)
Orientador: Marcos Augusto de Moraes e Silva / Coorientador: Juliana Bassalobre Carvalho Borges / Banca: Rubens Ramos de Andrade / Banca: Reinaldo Ayer de Oliveira / Banca: Alfredo José Rodrigues / Banca: Cláudio José Rubira / Resumo: Desde os primeiros relatos (1957 e 1959) até os tempos atuais, não há dúvida de que os marca-passos cardíacos modificaram a história natural das doenças do ritmo cardíaco. No entanto, o fato de prolongarem a sobrevida dos pacientes que se beneficiaram dessa tecnologia não tem, ainda nos dias de hoje, uma avaliação da sua influência na qualidade de vida (QV) que responda a todas as questões pertinentes. O objetivo do presente estudo foi avaliar a percepção da QV em pacientes portadores de marca-passo (MP) cardíaco definitivo e a sua relação com gênero, classe funcional (CF), idade, índice de massa corporal (IMC), modo de estimulação e tempo de implante. Foram estudados 107 pacientes, de ambos os gêneros (50,5% masculino e 49,5% feminino), com tempo de implante de MP entre um e doze meses (média de 6,36 ± 2,99 meses), estáveis clinicamente e com idade acima de 18 anos (média de 69,3 ± 12,6 anos). Os voluntários foram avaliados utilizando-se protocolo com dados pessoais, sinais vitais, antecedentes pessoais e perguntas referentes ao MP cardíaco. Foram aplicados também testes específicos como: IMC, CF (Goldman) e questionários de QV (SF-36 e AQUAREL). Foi realizada análise estatística pelos testes t, Kruskal-Wallis e correlação de Spearman, com nível de significância de 5%. O estudo foi aprovado pelo Comitê de Ética em Pesquisa Envolvendo Seres Humanos, da Faculdade de Medicina de Marília. Encontraram-se 70% dos pacientes com CF I e 63,4% acima do peso (média IMC 27,2 ± 7,86). A maioria das indicações para implante foi por bloqueios atrioventriculares (57,9%) e doença do nó sinusal (28%), sendo os marca-passos bicamerais utilizados em 86,9%. As principais comorbidades encontradas foram: doença de Chagas, hipertensão arterial sistêmica e diabetes mellitus. No questionário SF-36, o menor escore ocorreu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Since the first reports (1957, 1959) until nowadays, there is no doubt that cardiac pacemakers changed the natural history of the cardiac rhythm diseases. However, the fact that prolonging survival of patients who have benefited from this technology has not yet today, an assessment of its impact on quality of life (QoL) to answer all relevant questions. The aim of this trial was to evaluate the perception of QoL in patients using definitive cardiac pacemaker, and its relation with gender, functional class (FC), age, Body Mass Index (BMI), pacing mode, and time of implant. One hundred and seven patients were evaluated (50,5% male and 49.5% female), with implant time of the pacemaker between one and 12 months (mean 6.36 ±2.99 months), clinically stables, and aged ≥18 years (mean 69.3 ±12.6 years). Subjects were evaluated using a protocol that included: personal data, vital signs, personal history, and questions regarding the cardiac pacemaker. It also included specific tests, such as: BMI, functional class (FC; Goldman) and QoL questionnaires (SF-36 and AQUAREL). Statistical analysis with t test, Kruskal-Wallis and Spearman correlation, 5% significance level, were conducted. The trial was approved by the Committee of Ethics in Research Involving Humans, Marília's Medical School. The investigators found 70.0% of the patients with functional class I (FC I) and 63.4% (overall) overweight (mean BMI 27.2 ±7.86). Most of the implant indications were atrioventricular block (57.9%) and sinus node disease (28%). Bicameral pacemaker was used in 86.9% of the patients. Primary co-morbidities were: Chagas Disease, systemic hypertension and Diabetes Mellitus. The lowest score at SF-36 questionnaire was at the domain Physical Aspects, with 58.4, and the highest at Social Aspects, with 89.1. The lowest score at Aquarel questionnaire was found at the domain... (Complete abstract click electronic access below) / Doutor
|
12 |
Revisão sistemática de ensaios clínicos randomizados sobre terapia de ressincronização cardíaca: uso do marcapasso multissítio. / Systematic review of randomized controlled trials on cardiac resynchronization therapy: use of the multisite pacingLemos Júnior, Hernani Pinto de [UNIFESP] January 2006 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:44:27Z (GMT). No. of bitstreams: 0
Previous issue date: 2006 / Objetivos: determinar em pacientes com insuficiência cardíaca congestiva a eficácia da terapia de ressincronização cardíaca. Métodos:- Desenho do estudo: Revisão Sistemática; estratégia de busca: a)on line: LlLACS, MEDLlNE, Cochrane Library, Embase; b)busca manual; c)comunicação pessoal; d)Contato com industria farmacêutica. Critérios de seleção: a)Tipos de estudos: todos estudos controlados e randomizados elegíveis; b) Tipos de participantes: pacientes com insuficiência cardíaca congestiva e com fração de ejeção ventricular com fração de ejeção igualou menor que 40 por cento em tratamento farmacológico; c) Intervenção: terapia de ressincronização cardíaca através do marca¬passo multisítio com e sem desfibrilador comparado com tratamento farmacológico otimizado ou marca-passo univentricular; d)Desfechos: mortalidade, hospitalização por insuficiência cardíaca, teste de distância percorrida em seis minutos, classe funcional (New York Heart Association-NYHA-class,) e qualidade de vida. Coleta de dados e análises: dois revisores inspecionaram as referências encontradas independentemente pela estratégia de busca, e aplicaram os critérios de inclusão nos estudos selecionados usando os critérios de qualidade metodológica descritos no Cochrane Handbook. A escala de Jadad também foi usada Resultados: em nove estudos clínicos randomizados, com 3651 pacientes, com NYHA CLASS II, III ou IV, todos com intervalo QRS prolongado, a terapia de resincronização cardíaca melhorou a média do teste da distância percorrida em seis minutos (IC= 11.65, 35.15), a qualidade de vida (IC= -12.36, -7.39), reduziu o risco absoluto em 20 por cento na classe funcional (IC= 1.45, 3.82, NNT= 5); diminuiu as hospitalizações por insuficiência cardíaca (IC= 0.40, 0.90, NNT= 11, Diferença de risco= 9 por cento), e a mortalidade por quaisquer causas (IC= 0.45, 0.92, NNT= 17, Diferença de risco= 6 por cento); não foram observadas diferenças significativas entre as proporções de mortes por insuficiência cardíaca progressiva (IC= 0,56, 1.04). Conclusões: O marca passo multissítio oferece uma melhora funcional e hemodinâmica reduzindo a morbidade. A mortalidade de causas gerais não específicas foi menor no grupo com marcapasso multissítio, sem interferir na mortalidade de origem cardíaca. O tempo reduzido da maioria dos estudos torna difícil assegurar a segurança e a eficácia da terapia de ressincronização cardíaca. / Introduction: Congestive heart failure is a disease with progressive morbidity and mortality although
exist many drugs in use. Objectives: To determine in patients with symptomatic congestive heart failure the effectiveness of the cardiac resynchronization therapy. Methods: Search strategy: a)on line: LILACS, MEDLINE, Cochrane Centers; b) manual search; c) personal communication; d)Contact with industries. Selection criteria:- a)Types of studies: all eligible randomized controlled studies; b) Types of participants: patients with congestive heart failure and with reduced left ventricular ejection fraction; c) Intervention: cardiac resynchronization therapy with and without cardiodefibrillator compared with therapy isolated with drugs or univentricular pacemaker; d)Outcomes: mortality, hospitalization for heart failure, six-minutes walked distance test, functional status (New York Heart Association-NYHA-Class,), quality of life. Analyses: two reviewers inspected the references found independently with the search strategy, and they applied the inclusion criteria in the selected studies using the criteria of methodological quality described in Cochrane Handbook. The scale of Jadad was also used. After finding all eligible studies, the data were summarized in metanalysis. Results: In nine randomized clinical studies, with 3651 patient, with NYHA CLASS II, III, or IV, 100% with QRS width, the cardiac resynchronization therapy improved the six-minutes walked distance test (CI= 11.65, 35.15), the quality of life (CI= -12.36, -7.39), the functional status (CI= 1.45, 3.82, NNT= 5, Risk difference= 20%); reduced the hospitalizations for heart failure (CI= 0.40, 0.90, NNT= 11, Risk Difference= 9%), and the mortality for all causes (CI= 0.45, 0.92, NNT= 25, Risk difference= 4%); it was not seen significant differences deaths for progressive heart failure (CI=0,56, 1.04).
Conclusions: The multisite pacing offers a functional and hemodinamic improvement reducing the morbidity and all-cause mortality, without interfering in heart failure deaths. / BV UNIFESP: Teses e dissertações
|
13 |
Qualidade de vida em pacientes portadores de marca-passo cardíacoBarros, Rubens Tofano de [UNESP] 29 January 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:04Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-01-29Bitstream added on 2014-06-13T20:25:55Z : No. of bitstreams: 1
barros_rt_dr_botfm.pdf: 560972 bytes, checksum: 3a92a5f568be451ba327e50a714fcef3 (MD5) / Desde os primeiros relatos (1957 e 1959) até os tempos atuais, não há dúvida de que os marca-passos cardíacos modificaram a história natural das doenças do ritmo cardíaco. No entanto, o fato de prolongarem a sobrevida dos pacientes que se beneficiaram dessa tecnologia não tem, ainda nos dias de hoje, uma avaliação da sua influência na qualidade de vida (QV) que responda a todas as questões pertinentes. O objetivo do presente estudo foi avaliar a percepção da QV em pacientes portadores de marca-passo (MP) cardíaco definitivo e a sua relação com gênero, classe funcional (CF), idade, índice de massa corporal (IMC), modo de estimulação e tempo de implante. Foram estudados 107 pacientes, de ambos os gêneros (50,5% masculino e 49,5% feminino), com tempo de implante de MP entre um e doze meses (média de 6,36 ± 2,99 meses), estáveis clinicamente e com idade acima de 18 anos (média de 69,3 ± 12,6 anos). Os voluntários foram avaliados utilizando-se protocolo com dados pessoais, sinais vitais, antecedentes pessoais e perguntas referentes ao MP cardíaco. Foram aplicados também testes específicos como: IMC, CF (Goldman) e questionários de QV (SF-36 e AQUAREL). Foi realizada análise estatística pelos testes t, Kruskal-Wallis e correlação de Spearman, com nível de significância de 5%. O estudo foi aprovado pelo Comitê de Ética em Pesquisa Envolvendo Seres Humanos, da Faculdade de Medicina de Marília. Encontraram-se 70% dos pacientes com CF I e 63,4% acima do peso (média IMC 27,2 ± 7,86). A maioria das indicações para implante foi por bloqueios atrioventriculares (57,9%) e doença do nó sinusal (28%), sendo os marca-passos bicamerais utilizados em 86,9%. As principais comorbidades encontradas foram: doença de Chagas, hipertensão arterial sistêmica e diabetes mellitus. No questionário SF-36, o menor escore ocorreu... / Desde os primeiros relatos (1957 e 1959) até os tempos atuais, não há dúvida de que os marca-passos cardíacos modificaram a história natural das doenças do ritmo cardíaco. No entanto, o fato de prolongarem a sobrevida dos pacientes que se beneficiaram dessa tecnologia não tem, ainda nos dias de hoje, uma avaliação da sua influência na qualidade de vida (QV) que responda a todas as questões pertinentes. O objetivo do presente estudo foi avaliar a percepção da QV em pacientes portadores de marca-passo (MP) cardíaco definitivo e a sua relação com gênero, classe funcional (CF), idade, índice de massa corporal (IMC), modo de estimulação e tempo de implante. Foram estudados 107 pacientes, de ambos os gêneros (50,5% masculino e 49,5% feminino), com tempo de implante de MP entre um e doze meses (média de 6,36 ± 2,99 meses), estáveis clinicamente e com idade acima de 18 anos (média de 69,3 ± 12,6 anos). Os voluntários foram avaliados utilizando-se protocolo com dados pessoais, sinais vitais, antecedentes pessoais e perguntas referentes ao MP cardíaco. Foram aplicados também testes específicos como: IMC, CF (Goldman) e questionários de QV (SF-36 e AQUAREL). Foi realizada análise estatística pelos testes t, Kruskal-Wallis e correlação de Spearman, com nível de significância de 5%. O estudo foi aprovado pelo Comitê de Ética em Pesquisa Envolvendo Seres Humanos, da Faculdade de Medicina de Marília. Encontraram-se 70% dos pacientes com CF I e 63,4% acima do peso (média IMC 27,2 ± 7,86). A maioria das indicações para implante foi por bloqueios atrioventriculares (57,9%) e doença do nó sinusal (28%), sendo os marca-passos bicamerais utilizados em 86,9%. As principais comorbidades encontradas foram: doença de Chagas, hipertensão arterial sistêmica e diabetes mellitus... (Complete abstract click electronic access below)
|
14 |
Efeito hemodinamico da sincronização eletrica biventricular prolongada no pos-operatorio de revascularização do miocardio / Hermodynamic effects of biventricular stimulation in patients at post-operative period of coronary arterybypass surgeryLima, Jose Marco Nogueira 15 March 2006 (has links)
Orientador: Kleber Gomes Franchini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T19:09:29Z (GMT). No. of bitstreams: 1
Lima_JoseMarcoNogueira_D.pdf: 1108641 bytes, checksum: 52decb99b4c7eb40cf6e3df4bdda5d47 (MD5)
Previous issue date: 2006 / Resumo: O presente estudo tem como objetivo avaliar a influência da estimulação biventricular prolongada no pós-operatório de revascularização miocárdica em pacientes portadores de disfunção ventricular esquerda, FE = 40%, associada à duração do QRS menor ou igual a 130ms. Foram selecionados 21 pacientes dos quais 16 foram randomizados em dois grupos denominados: Grupo de estimulação biventricular (Grupo EBV) e Grupo Controle. Os dois grupos foram submetidos à monitorização contínua por um período de 12 horas com os seguintes parâmetros coletados: parâmetros hemodinâmicos sistêmicos (pressão arterial média, índice de resistência vascular sistêmica e temperatura), parâmetros hemodinâmicos cardíacos (débito cardíaco, índice cardíaco, índice do volume sistólico do ventrículo esquerdo e freqüência cardíaca) e parâmetros hemodinâmicos pulmonares (pressão em cunha de capilar pulmonar, pressão venosa central e índice de resistência vascular pulmonar). Para análise dos resultados foram empregados o teste t de Student, teste de Wilcoxon, teste exato de Fisher, teste de Wilks e MANOVA. A sincronização obtida através da estimulação biventricular sob captação atrial (sinusal) aumentou o índice cardíaco em conseqüência do aumento do volume sistólico. Observou-se também uma redução significativa da resistência vascular sistêmica em comparação com os pacientes não estimulados. Esses efeitos permaneceram nas 6 horas que se seguiram após a parada da estimulação no Grupo EBV. Não houve diferença estatisticamente significativa na pressão arterial média entre os grupos. O grupo estimulado apresentou uma menor pressão em cunha de capilar pulmonar do que o grupo controle durante o período da estimulação. Podemos concluir que a estimulação biventricular produziu nesses pacientes uma melhora do desempenho sistólico do ventrículo esquerdo por restaurar a coordenação da contratilidade cardíaca em conseqüência da sincronização independente da variável freqüência cardíaca e duração do QRS / Abstract: The present study aims to evaluate the influence of lengthened biventricular stimulation on the post-surgical period of myocardical revascularization in patients that carry left ventricular dysfunction, FE = 40%, associated to QRS endurance equal to or less than 130 ms. From a selection of 21 patients, 16 of which were randomized in 2 groups named: Biventricular Stimulation Group (EBV Group) and Control Group. Both groups have been submitted to a 12-hour continuous monitoring period, with the following parameters being collected: systemic hemodynamic parameters (mean arterial pressure, systemic vascular resistance index and temperature), cardiac hemodynamic parameters (cardiac output, cardiac index, left ventricle stroke volume index and heart rate) and pulmonary hemodynamic parameters (pulmonary artery wedge pressure, central venous pressure and pulmonary vascular resistance index). For the analysis of the results we have applied the Student's t test, Wilcoxon rank-sum test, Fisher's exact test, Wilks' test and MANOVA. The synchronization obtained through biventricular stimulation under atrial sense increased the cardiac index, as a consequence of the increased systolic volume. A significant reduction of systemic vascular resistance has also been observed, in comparison to that of the non-stimulated patients. These effects have endured for the 6-hour period that succeeded the interruption of the stimulation in the EBV Group. There was no statistically significant difference in the average blood pressure between the groups. The stimulated group presented a lower pulmonary artery wedge pressure than that of the control group over the stimulation period. We can concluded the biventricular stimulation has produce an improvement on the systolic performance as the left ventricular do the restoration of the ventricular contractibility as a consequence of a synchronization that the not depend the frequency and the QRS lasting / Doutorado / Medicina Experimental / Doutor em Fisiopatologia Medica
|
15 |
Aspectos tecnicos da cateterização do seio coronariano baseado no componente atrial do eletrograma intracavitario durante o procedimento de implante de marcapasso biventricular / Technical aspects of coronary sinus catheterization based on the atrial component of the intracavitary eletrogram and radiological anatomy during implantation procedure of a biventricular pacemakerSouza, Fernando Sergio Oliva de 17 April 2008 (has links)
Orientador: Orlando Petrucci Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T10:51:42Z (GMT). No. of bitstreams: 1
Souza_FernandoSergioOlivade_D.pdf: 1025341 bytes, checksum: 15ba5e4c6177129ac03b697eb1f59cb9 (MD5)
Previous issue date: 2008 / Resumo: A estimulação elétrica biventricular apresenta bons resultados no tratamento da insuficiência cardíaca congestiva refratária em portadores de cardiomiopatia dilatada com distúrbios de condução interventricular. OBJETIVO: Apresentar proposição utilizando técnica original simplificada para o implante de eletrodo de estimulação ventricular esquerda epicárdica, baseado na anatomia radiológica e no eletrograma intracavitário,enfatizando o componente atrial, demonstrando o resultado, complicações, ressaltando tempo total de utilização de fluoroscópio. CASUÍSTICA E MÉTODO: De Outubro de 2001 a Março de 2007 foram realizados 234 implantes de marca-passo biventricular em pacientes previamente selecionados, utilizando-se anatomia radiológica e observação de eletrograma intracavitário, dando-se prioridade ao componente atrial, demonstrando a taxa de sucesso, complicações e tempo total de utilização de radioscopia. RESULTADOS: O implante do sistema, utilizando-se a estimulação do ventrículo esquerdo via seio coronariano não foi possível em 19(8,1%) pacientes. Em 30(12,8%) pacientes foram observadas dificuldades na canulação do óstio coronário e em 52(22%) pacientes observaram-se dificuldades de progressão do eletrodo através do seio coronário. O tempo médio de utilização de radioscopia foi 18,69(±15,2) min. CONCLUSÃO: A utilização da técnica simplificada para cateterização do seio coronário sem utilização de bainha, baseada na anatomia radiológica e no eletrograma intracavitário, enfatizando o componente atrial, no tratamento de portadores de cardiomiopatia dilatada avançada, pela terapia de ressincronização cardíaca, demonstrou resultado satisfatório, índice de complicações pequeno, e baixa exposição do operador a radiação ionizante / Abstract: Biventricular pacing has present good results in treatment of congestive cardiac heart failure in patients with dilated miocardyopathy and interventricular conduction disturbance. PURPOSE: to present a proposal of using a original simplified technique for left epicardial ventricular lead stimulation, based on the radiological imaging of the anatomy and intracavitary electrogram, emphasizing the atrial component, showing the results, complications, highlighting the total fluoro time. METHODS: From October, 2001 up to March, 2007, 234 biventricular pacemaker implantations were performed in previously selected patients, using radiological anatomy and observation of the intracavitary electrogram, focusing on the atrial component, and showing the success rate, complications and total time of radioscopy utilization. RESULTS: The implantation of the system using left ventricular pacing via coronary sinus was not possible in 19(8,1%) patients. Difficulties on the cannulation of the coronary ostium were felt in 30(12,8%) patients and difficulties of lead advancement through the coronary sinus were felt in 52(22%) patients. The mean time of radioscopy utilization was 18.69(±15,2) min. CONCLUSION: the use of a simplified technique for coronary sinus cannulation without the aid of a sheath, based on the radiological imaging of the anatomy and intracavitary electrogram, emphasizing the atrial component, for the treatment of advanced dilated cardiomyopathy patients with cardiac resynchronization therapy, has shown satisfactory results, low incidence of complications, and low exposure of the operator to ionizing radiation / Doutorado / Cirurgia / Doutor em Cirurgia
|
16 |
Avaliação de dessincronia atrioventricular em portadores de marca-passo bicameral devido à doença do nó sinusal e bloqueio atrioventricular de primeiro grau / Evaluation of atrioventricular dyssynchrony in patients with dual-chamber pacemaker implanted due to sinus node disease and first degree atrioventricular blockFerrari, Andres Di Leoni 18 May 2017 (has links)
INTRODUÇÃO: O intervalo PR longo, em conjunto com a duração e a morfologia do QRS gerado pela estimulação cardíaca artificial, associam-se com dessincronia e disfunção cardíaca em diferentes níveis. Na doença do nó sinusal, durante a programação do marca-passo, podemos optar por duas estratégias: PR longo com QRS estreito (quando se busca evitar a ativação ventricular em detrimento do sincronismo atrioventricular) ou PR otimizado e QRS largo estimulado pelo marca-passo (quando se busca corrigir o intervalo atrioventricular em detrimento da sincronia ventricular). Neste estudo, buscamos comparar a evolução clínica e estrutural cardíaca destas estratégias. MÉTODOS: Acompanhou-se por 1 ano uma coorte com doença do nó sinusal, bloqueio atrioventricular de 1º grau (doença binodal) e marca-passo DDD. Através da ecocardiografia Doppler de fluxo transmitral avaliou-se a duração do enchimento diastólico ventricular e sincronia atrioventricular (? ondas E+A>=40% do ciclo cardíaco). Os pacientes dessincrônicos (DAV) tiveram o intervalo atrioventricular otimizado (intervenção) ao melhor rendimento hemodinâmico, porém com QRS estimulado. Estes retornavam ao PR basal após 6 meses (cross-over). Os sincrônicos (SAV) foram mantidos sob PR longo e QRS intrínseco durante todo o seguimento (controles). RESULTADOS: Quarenta e três pacientes foram incluídos e 41 completaram o estudo (idade média= 71,5 anos). Confirmou-se a existência dos 2 grupos (p= <0.001): os SAV (n=19), distintos daqueles com dessincronia atrioventricular (DAV, n=24). PR>=263ms mostrou especificidade de 78,9% para diagnóstico de dessincronia AV, e a maior duração do PR mostrou relação direta com pior função sistólica ventricular basal. Os DAV eram predominantemente homens, tinham PR mais longos (média= 283,5ms) e menor duração da diástole (p= 0.032). Um subgrupo dos DAV com PR >300ms mostrou pior qualidade de vida, maior duração do QRS quando estimulado, e dessincronia não corrigível por otimização. De modo notável, em 6 meses, o grupo DAV mostrou tendência a melhora da FEVE apesar do QRS alargado, e decréscimo ao retornar ao basal. O grupo SAV apresentava PR longo antifisiológico e evolutivamente piora da regurgitação mitral (p= 0.008) e também registros de fibrilação atrial de aparição mais precoce. Foram preditores independentes de dessincronia atrioventricular o PR >263ms (RR= 1,84; p= 0.024) e a duração da diástole inferior a 40% do ciclo cardíaco (RR= 0,99; p<0.001). CONCLUSÕES: Em pacientes com doença binodal e marca-passo DDD, a mera intenção de evitar o QRS largo da estimulação ventricular artificial não resolve todos os problemas. Intervalos PR longos (>263ms) associados ao decréscimo do enchimento diastólico ventricular caracterizariam outro prejuízo eletromecânico cardíaco: a dessincronia atrioventricular, disfunção que tem repercussão hemodinâmica, clínica e estrutural. / BACKGROUND: Long PR interval and wide QRS duration duo to ectopic morphology generated by artificial cardiac pacing are associated with cardiac dysfunction and dyssynchrony at different levels. When programming a permanent pacemaker in sinus node disease, two strategies can be considered: long PR with narrow QRS (avoiding ventricular pacing despite the risk of losing atrioventricular syncrony) or optimized PR interval with pacemaker-induced wide QRS (aiming to correct the atrioventricular delay despite loss of the ventricular synchrony). In this study, we aimed to compare the clinical and cardiac structural outcomes of these two strategies. METHODS: Sudy a cohort of patients with sinus node disease, first-degree AV block (binodal disease) and DDD pacemaker was followed for 1 year follow-up. atrioventrucular synchrony (AVS) was assessed echocardiographically by the ventricular diastolic filling time on Doppler transmitral flow: sum of the duration of E and A waves >=40% of the cardiac cycle. Patients with AV dyssynchrony (AVD) had the AV delay optimized (intervention group) for the best hemodynamic performance, but under wide artificially paced QRS. These returned to baseline PR interval after 6 months (cross-over). Those with AVS were kept under intrinsic QRS throughout the follow-up period despiste long PR interval (control group). RESULTS: Forty-three patients were included (mean age = 71.5 years), and 41 completed the 1-year follow-up. The existence of the 2 groups was confirmed (p<=0.001): patients with AVS (n=19), differed from those with AVD (n=24). Within a homogeneous sample (mean age= 71.5 years), PR >=263 ms had a specificity of 78.9% for the diagnosis of AVD, and longer PR intervals were associated with worse baseline ventricular systolic function. Most patients with AVD were men, had longer PR intervals (mean= 283.5 ms), and had significantly lower diastole duration (p= 0.032). A subgroup of AVD patients with PR >300 ms had poorer quality of life, significantly greater use of ?-blockers (p= 0.011), longer paced QRS width, and AV dyssynchrony that is non-correctable by optimization. Notably, at 6 months, the AVD group lean towards to have better LVEF values despite the wide QRS and a decrease when returning to baseline. Patients with AVS also had PR intervals different from the physiological condition (157.9 to 330 ms) and, over time, had worsening of mitral regurgitation (p=0.008) and earlier atrial fibrillation. PR>263 ms (RR= 1.84; p= 0.024) and diastole duration <40% of the cardiac cycle (RR= 0.99; p<0.001) were independent predictors of AVD. CONCLUSIONS: For patients with binodal disease and DDD pacemaker, the strategy of avoiding the wide QRS, usually applied by modern algorithms for minimizing ventricular pacing, is not enough to solve all problems. Long PR intervals (>=263 ms) may be associated with decreased ventricular diastolic filling time and characterize another cardiac electromechanical impairment: AV dyssynchrony, with hemodynamic, clinical and structural repercussions by itself.
|
17 |
Avaliação de dessincronia atrioventricular em portadores de marca-passo bicameral devido à doença do nó sinusal e bloqueio atrioventricular de primeiro grau / Evaluation of atrioventricular dyssynchrony in patients with dual-chamber pacemaker implanted due to sinus node disease and first degree atrioventricular blockAndres Di Leoni Ferrari 18 May 2017 (has links)
INTRODUÇÃO: O intervalo PR longo, em conjunto com a duração e a morfologia do QRS gerado pela estimulação cardíaca artificial, associam-se com dessincronia e disfunção cardíaca em diferentes níveis. Na doença do nó sinusal, durante a programação do marca-passo, podemos optar por duas estratégias: PR longo com QRS estreito (quando se busca evitar a ativação ventricular em detrimento do sincronismo atrioventricular) ou PR otimizado e QRS largo estimulado pelo marca-passo (quando se busca corrigir o intervalo atrioventricular em detrimento da sincronia ventricular). Neste estudo, buscamos comparar a evolução clínica e estrutural cardíaca destas estratégias. MÉTODOS: Acompanhou-se por 1 ano uma coorte com doença do nó sinusal, bloqueio atrioventricular de 1º grau (doença binodal) e marca-passo DDD. Através da ecocardiografia Doppler de fluxo transmitral avaliou-se a duração do enchimento diastólico ventricular e sincronia atrioventricular (? ondas E+A>=40% do ciclo cardíaco). Os pacientes dessincrônicos (DAV) tiveram o intervalo atrioventricular otimizado (intervenção) ao melhor rendimento hemodinâmico, porém com QRS estimulado. Estes retornavam ao PR basal após 6 meses (cross-over). Os sincrônicos (SAV) foram mantidos sob PR longo e QRS intrínseco durante todo o seguimento (controles). RESULTADOS: Quarenta e três pacientes foram incluídos e 41 completaram o estudo (idade média= 71,5 anos). Confirmou-se a existência dos 2 grupos (p= <0.001): os SAV (n=19), distintos daqueles com dessincronia atrioventricular (DAV, n=24). PR>=263ms mostrou especificidade de 78,9% para diagnóstico de dessincronia AV, e a maior duração do PR mostrou relação direta com pior função sistólica ventricular basal. Os DAV eram predominantemente homens, tinham PR mais longos (média= 283,5ms) e menor duração da diástole (p= 0.032). Um subgrupo dos DAV com PR >300ms mostrou pior qualidade de vida, maior duração do QRS quando estimulado, e dessincronia não corrigível por otimização. De modo notável, em 6 meses, o grupo DAV mostrou tendência a melhora da FEVE apesar do QRS alargado, e decréscimo ao retornar ao basal. O grupo SAV apresentava PR longo antifisiológico e evolutivamente piora da regurgitação mitral (p= 0.008) e também registros de fibrilação atrial de aparição mais precoce. Foram preditores independentes de dessincronia atrioventricular o PR >263ms (RR= 1,84; p= 0.024) e a duração da diástole inferior a 40% do ciclo cardíaco (RR= 0,99; p<0.001). CONCLUSÕES: Em pacientes com doença binodal e marca-passo DDD, a mera intenção de evitar o QRS largo da estimulação ventricular artificial não resolve todos os problemas. Intervalos PR longos (>263ms) associados ao decréscimo do enchimento diastólico ventricular caracterizariam outro prejuízo eletromecânico cardíaco: a dessincronia atrioventricular, disfunção que tem repercussão hemodinâmica, clínica e estrutural. / BACKGROUND: Long PR interval and wide QRS duration duo to ectopic morphology generated by artificial cardiac pacing are associated with cardiac dysfunction and dyssynchrony at different levels. When programming a permanent pacemaker in sinus node disease, two strategies can be considered: long PR with narrow QRS (avoiding ventricular pacing despite the risk of losing atrioventricular syncrony) or optimized PR interval with pacemaker-induced wide QRS (aiming to correct the atrioventricular delay despite loss of the ventricular synchrony). In this study, we aimed to compare the clinical and cardiac structural outcomes of these two strategies. METHODS: Sudy a cohort of patients with sinus node disease, first-degree AV block (binodal disease) and DDD pacemaker was followed for 1 year follow-up. atrioventrucular synchrony (AVS) was assessed echocardiographically by the ventricular diastolic filling time on Doppler transmitral flow: sum of the duration of E and A waves >=40% of the cardiac cycle. Patients with AV dyssynchrony (AVD) had the AV delay optimized (intervention group) for the best hemodynamic performance, but under wide artificially paced QRS. These returned to baseline PR interval after 6 months (cross-over). Those with AVS were kept under intrinsic QRS throughout the follow-up period despiste long PR interval (control group). RESULTS: Forty-three patients were included (mean age = 71.5 years), and 41 completed the 1-year follow-up. The existence of the 2 groups was confirmed (p<=0.001): patients with AVS (n=19), differed from those with AVD (n=24). Within a homogeneous sample (mean age= 71.5 years), PR >=263 ms had a specificity of 78.9% for the diagnosis of AVD, and longer PR intervals were associated with worse baseline ventricular systolic function. Most patients with AVD were men, had longer PR intervals (mean= 283.5 ms), and had significantly lower diastole duration (p= 0.032). A subgroup of AVD patients with PR >300 ms had poorer quality of life, significantly greater use of ?-blockers (p= 0.011), longer paced QRS width, and AV dyssynchrony that is non-correctable by optimization. Notably, at 6 months, the AVD group lean towards to have better LVEF values despite the wide QRS and a decrease when returning to baseline. Patients with AVS also had PR intervals different from the physiological condition (157.9 to 330 ms) and, over time, had worsening of mitral regurgitation (p=0.008) and earlier atrial fibrillation. PR>263 ms (RR= 1.84; p= 0.024) and diastole duration <40% of the cardiac cycle (RR= 0.99; p<0.001) were independent predictors of AVD. CONCLUSIONS: For patients with binodal disease and DDD pacemaker, the strategy of avoiding the wide QRS, usually applied by modern algorithms for minimizing ventricular pacing, is not enough to solve all problems. Long PR intervals (>=263 ms) may be associated with decreased ventricular diastolic filling time and characterize another cardiac electromechanical impairment: AV dyssynchrony, with hemodynamic, clinical and structural repercussions by itself.
|
18 |
Efeitos da terapia de ressincronização cardíaca (TRC) sobre a perfusão miocárdica: correlações clínico-funcionais / Effects of cardiac resynchronization therapy (CRT) on myocardial perfusion: clinical and functional correlationsBrandão, Simone Cristina Soares 17 September 2008 (has links)
Introdução: a cintilografia cardíaca com MIBI-99mTc sincronizada ao eletrocardiograma (gated SPECT) avalia integridade celular, perfusão miocárdica e função global e regional do ventrículo esquerdo (VE). A terapia de ressincronização cardíaca (TRC) pode melhorar os sintomas de insuficiência cardíaca (IC), mas seus benefícios sobre a função do VE são menos pronunciados. Objetivos: avaliar se as mudanças na captação miocárdica do MIBI-99mTc após a TRC estão associadas à melhora clínica, à redução do QRS ao eletrocardiograma e ao desempenho do VE e se a gated SPECT adiciona informação na seleção e acompanhamento de pacientes para a TRC. Método: trinta pacientes (idade media 59 ± 11 anos, 47% masculinos) com miocardiopatia dilatada não isquêmica, IC classe funcional III ou IV da New York Heart Association com tratamento medicamentoso otimizado, bloqueio de ramo esquerdo e fração de ejeção do ventrículo esquerdo (FEVE) inferior a 35% participaram deste estudo. Foram avaliados pré e três meses após TRC as seguintes variáveis: classe funcional de IC, duração do QRS, FEVE pela ecocardiografia, captação miocárdica do MIBI-99mTc (%) ao repouso e após estresse com adenosina, volumes diastólico (VDF) e sistólico finais (VSF) do VE, motilidade e espessamento regionais nas paredes do VE pela Gated SPECT. Após TRC, os pacientes foram divididos em dois grupos de acordo com a melhora na FEVE: grupo 1 (G1=12 pacientes) com aumento 5 pontos absolutos; e grupo 2 (G2=18 pacientes) sem aumento significante. Resultados: após TRC, ambos os grupos melhoraram significantemente a classe funcional de IC, reduziram QRS e aumentaram a captação miocárdica do MIBI-99mTc nas paredes ântero-septal e ínfero-septal. Apenas G1 apresentou mudanças favoráveis no VDF, VSF, motilidade e espessamento regionais do VE. Pré TRC, pela análise univariada, o VDF e ESV foram estatisticamente maiores no G2 em relação ao G1 (VDF: 477 ± 168 mL vs. 276 ± 94 mL, p<0,001; VSF: 401 ± 154 mL vs. 220 ± 85 mL, p<0,001, G2 e G1, respectivamente). A captação miocárdica do MIBI-99mTc foi menor no G2 em relação ao G1 nas paredes anterior (60 ± 10% vs. 67 ± 7%, p=0,049, repouso) e inferior (48 ± 10% vs. 59 ± 11%, repouso, e 47 ± 10% vs. 58 ± 9%, p=0,003, após estresse). A soma dos escores de hipocaptação após estresse foi significantemente maior no G2 em relação ao G1 (14 ± 9 e 9 ± 4, G2 e G1, respectivamente, p=0,039). Pela análise multivariada, o VDF foi o único preditor independente de aumento na FEVE após terapia, p=0,01. O ótimo ponto de corte do VDF pela curva ROC para predizer melhora na FEVE após terapia foi 315 mL com sensibilidade de 89% e especificidade de 94%. Conclusões: A TRC aumentou a captação miocárdica regional de MIBI-99mTc, melhorou a classe funcional de IC e reduziu QRS independentemente da melhora do desempenho cardíaco. Após TRC, o aumento da FEVE ocorreu em corações menos dilatados e com uma maior captação miocárdica regional do MIBI-99mTc, principalmente na parede inferior / Background: gated myocardial scintigraphy with 99mTc-MIBI (gated SPECT) evaluates myocyte integrity, myocardial perfusion and global and regional left ventricular (LV) function. Cardiac resynchronization therapy (CRT) may improve heart failure (HF) clinical symptoms, but its benefits for LV function are less pronounced. Objectives: we assessed whether changes on myocardial 99mTc-MIBI uptake post-CRT are related to improvement in clinical HF symptoms, reduction in QRS duration and improvement in LV performance, and whether gated SPECT with 99mTc-MIBI adds information to selection and follow-up of patients undergoing CRT. Methods: thirty patients (mean age 59 ± 11, 47% male) with nonischemic dilated cardiomyopathy, chronic HF in New York Heart Association functional class III or IV with optimized clinical treatment, left bundle-branch block, and LV ejection fraction (LVEF) inferior to 35% participated to this study. Pre- and 3 months post-CRT, the variables analyzed were: HF functional class, QRS duration, LVEF by echocardiography, myocardial 99mTc-MIBI uptake (%) at rest and after adenosine stress, LV end-diastolic (EDV) and end-systolic volumes (ESV), regional LV motion and thickness by gated SPECT. Post-CRT, patients were divided into 2 groups according to LVEF improvement: group 1 (G1=12 patients) with increase in LVEF5points and group 2 (G2=18 patients) without significant increase. Results: post-CRT, both groups improved significantly in HF functional class, reduced QRS width and increased antero-septal and infero-septal wall 99mTc-MIBI uptake. Only G1 had favorable changes in EDV, ESV, and LV regional motion and thickness. Pre- CRT, by univariate analysis, EDV and ESV were statistically higher in G2 compared with G1 (EDV: 477 ± 168 mL vs. 276 ± 94 mL, p<0.001; ESV: 401 ± 154 mL vs. 220 ± 85 mL, p<0.001, G2 and G1, respectively). Myocardial 99mTc-MIBI uptake was lower in G2 compared with G1 in the anterior wall (60 ± 10% vs. 67 ± 7%, p=0.049, at rest) and inferior wall (48 ± 10% vs. 59 ± 11%, at rest, and 47 ± 10% vs. 58 ± 9%, p=0.003, after adenosine stress). Summed stress score was significantly higher in G2 compared to G1 (14 ± 9 vs. 9 ± 4, G2 and G1, respectively, p=0.039). By multivariate analysis, EDV was the only independent predictor of LVEF increase posttherapy, p=0.01. By ROC curve, optimal EDV cutoff point was 315mL with 89% of sensitivity and 94% of specificity. Conclusions: CRT increased myocardial 99mTc- MIBI uptake, improved HF functional class, and reduced QRS width independently of LV performance improvement. Post-CRT, LVEF increase occurred in hearts less dilated showing higher regional myocardial 99mTc-MIBI uptake, mainly in the inferior wall
|
19 |
Avaliação das funções executivas em portadores de fibrilação atrial e insuficiência cardíaca / Evaluation of executive function in carriers of atrial fibrillation and heart failureVaughan, Renata Aparecida da Rocha 13 November 2017 (has links)
Introdução: A Insuficiência Cardíaca (IC) e a Fibrilação Atrial (FA) são patologias frequentes na população idosa e estão associadas a alterações da esfera cognitiva. No entanto, suas consequências sobre as funções executivas, responsáveis pela resolução de problemas, ainda não estão totalmente esclarecidas. Objetivo: investigar as características do funcionamento executivo em pacientes com FA e/ou IC e identificar se tal funcionamento é equiparável ao de um grupo controle. Método: Estudo observacional, de coorte transversal, realizado em hospital de atenção terciária em cardiologia que avaliou 191 sujeitos, com uma média de 69,1 anos de idade (mín.: 60; Max.: 82) distribuídos em cinco grupos distintos: com FA, com IC associada à FA, com IC e controles (com e sem marca-passo artificial MP). Os grupos foram pareados por faixa etária e variáveis sócio-demográficas, submetidos à avaliação neuropsicológica e a análise estatística envolveu testes não paramétricos (Kruskall-Wallys e Mann-Whitney), qui-quadrado de Pearson e teste exato de Fisher. Resultados: Nos indivíduos com FA comparados aos controles sem MP, observamos diferenças estatisticamente significativas relacionadas a memória operacional (p = 0,034), a memória tardia (p = 0,015), a memória semântica e fluência verbal (p < 0,001), a compreensão (p < 0,001), ao planejamento e a habilidade visuoespacial (p < 0,001), a percepção visual e a linguagem (p< 0,001) e ao controle inibitório e a velocidade de processamento, nas três fases do instrumento (p < 0,008; p < 0,004; p < 0,002). Já nos indivíduos com FA associada à IC, as diferenças observadas envolveram: a memória semântica e a fluência verbal (p = 0,05), o planejamento e a habilidade visuoespacial (p < 0,001), a percepção visual e a linguagem (p < 0,001) e o controle inibitório e a velocidade de processamento (p = 0,002; p < 0,001; p = 0,145, respectivamente). Os sujeitos com IC demonstraram o mesmo desempenho do grupo de indivíduos com FA e IC, com diferenças relacionadas às mesmas funções, exceto na primeira fase do instrumento que avaliou controle inibitório e a velocidade de processamento (p < 0,001). Quanto à funcionalidade, não observamos diferença estatisticamente significativa entre os grupos. Conclusões: O funcionamento executivo de indivíduos com FA ou IC não é equiparável ao de indivíduos sem essas doenças. A FA, de uma perspectiva neuropsicológica, intensifica o prejuízo das FE e também da memória / Introduction: Heart Failure (HF) and Atrial Fibrillation (AF) are frequent pathologies in the elderly population and are associated with cognitive disorders. However, its consequences on executive functions, which are responsible for solving problems, have not yet been fully clarified. Objective: to investigate the characteristics of executive functioning in patients with AF and/or HF and to identify if such functioning is comparable to that of a control group. Methods: A cross-sectional observational study performed in a tertiary care hospital in cardiology, which evaluated 191 subjects with a mean age of 69.1 years (min.: 60, Max.: 82) distributed in five different groups: AF, with HF associated with AF, with HF and controls (with and without pacemaker). The groups were matched by age group and socio-demographic variables, submitted to neuropsychological evaluation and statistical analysis involved non-parametric tests (Kruskall-Wallys and Mann-Whitney), Pearson\'s chi-square and Fisher\'s exact test. Results: In subjects with AF compared to non-pacemaker controls, we observed statistically significant differences related to operational memory (p = 0.034), late memory (p = 0.015), semantic memory and verbal fluency (p < 0.001), comprehension P < 0.001), visuospatial planning and ability (p < 0.001), visual perception and language (p < 0.001) and inhibitory control and processing speed in the three phases of the instrument (p < 0.008; p < 0.004, p < 0.002). In subjects with HF associated with HF, the observed differences involved: semantic memory and verbal fluency (p = 0.05), planning and visuospatial ability (p < 0.001), visual perception and language (p < 0.001) and inhibitory control and processing speed (p = 0.002, p < 0.001, p = 0.145, respectively). Subjects with HF demonstrated the same performance of the group of individuals with AF and HF, with differences related to the same functions, except in the first phase of the instrument that evaluated inhibitory control and processing speed (p < 0.001). Regarding functionality, we did not observe a statistically significant difference between groups. Conclusions: The executive functioning of individuals with AF or IC is not comparable to that of individuals without these diseases. AF, from a neuropsychological perspective, intensifies the damage of FE and memory
|
20 |
Estudo da segurança e da estabilidade do implante de cabo-eletrodo atrial direito pela via epidemiocárdiaca através do seio transverso em modelo animal suíno / Evaluation of safety and stability of right atrial lead implantation by epimyocardial access through the transverse sinus in a swine modelBueno, Sávia Christina Pereira 13 June 2013 (has links)
Introdução: Embora o implante de marcapasso atrioventricular pela via endovenosa seja considerado o estado da arte, situações clínicas e técnicas que podem impossibilitar o implante transvenoso de cabos-eletrodos têm sido cada vez mais frequentes, tornando-se necessária a proposição de abordagens cirúrgicas alternativas. Objetivos: O presente estudo visou o implante de marcapasso atrioventricular utilizando nova técnica para implante de cabo-eletrodo atrial no átrio direito, com o objetivo de avaliar no período intra-operatório e nos 30 primeiros dias de seguimento: a segurança e a reprodutibilidade do procedimento cirúrgico; a taxa de deslocamento dos cabos-eletrodos; as condições de estimulação e sensibilidade; as alterações morfológicas na cavidade pericárdica e as alterações histopatológicas epimiocárdicas. Métodos: Sob anestesia geral, foram operados 10 porcos adultos da raça Large White. Os cabos-eletrodos foram implantados, sob visão direta, no ventrículo esquerdo e no átrio direito, pelo seio transverso, através de toracotomia anterolateral esquerda. As condições de estimulação e de sensibilidade para os cabos-eletrodos atrial e ventricular, nas configurações unipolar e bipolar, foram avaliadas no intra-operatório, pós-operatório imediato, no 7º e 30º dias de pós-operatório. Ao final do estudo, os animais foram reoperados por toracotomia longitudinal mediana para observação das aderências pericárdicas e análise das condições histopatológicas da junção entre o cabo-eletrodo e o epimiocárdico. Resultados: Todos os animais permaneceram vivos até o último dia do estudo, não tendo ocorrido complicações intra-operatórias graves. As condições de estimulação e sensibilidade para os cabos-eletrodos atriais e ventriculares, nas configurações unipolar e bipolar, mantiveram-se estáveis ao longo do estudo e apresentaram comportamento semelhante. Notou-se aumento progressivo dos limiares atriais, variando de 0,50 ± 0,38 a 1,86 ± 1,31 volts nos períodos intra-operatório e 30o pós-operatório, respectivamente. Comportamento semelhante foi observado para os limiares ventriculares, que variaram de 0,43 ± 0,23 volts, no intra-operatório, a 1,22 ± 0,49 volts, no 30o pós-operatório. As medidas de impedância atrial e ventricular apresentaram uma discreta queda ao longo do tempo, sendo que a impedância atrial variou de 486,80 ± 126,35 a 385,0 ± 80,52 Ohms no período intra-operatório e 30o pós-operatório, respectivamente. A impedância ventricular variou de 700,40 ± 203,67 Ohms, no intra-operatório, a 409,30 ± 58,96 Ohms, no 30o pós-operatório. A sensibilidade, tanto em átrio quanto em ventrículo, mostrou-se estável a partir do pós-operatório imediato. A inspeção da cavidade pericárdica mostrou aderências em todos os animais e em todas as regiões avaliadas, não sendo observados derrame ou constrição pericárdica. A análise microscópica mostrou que o contato com os cabos-eletrodos provocou espessamento do epimiocárdio no átrio direito, ventrículo esquerdo e na artéria pulmonar. A cicatriz formada na junção entre o cabo-eletrodo e o epimiocárdio atrial foi semelhante à formada na região do implante dos cabos-eletrodos ventriculares. Conclusões: O implante do cabo-eletrodo atrial direito pelo seio transverso foi seguro e reprodutível. A efetividade do procedimento foi confirmada pelas condições estáveis de estimulação e de sensibilidade durante o período de seguimento pós-operatório. A única alteração morfológica encontrada na cavidade pericárdica foi a formação de aderências. Ocorreu adequada cicatrização na junção entre o cabo eletrodo e o epimiocárdio atrial / Introduction: Although transvenous access for atrioventricular pacemaker implantation is considered the state of the art, clinical and technical situations that may impede transvenous leads implantation have become increasingly common, making it necessary the proposal of new surgical approaches. Objectives: The present study was design to perform the implant of atrioventricular pacemaker using a new technique for placement of the atrial lead in the right atrium, aiming to evaluate in the intraoperative period and during the first 30 days of follow-up: the safety and reproducibility of the surgical procedure; lead dislodgment rate; conditions of pacing and sensing; morphological changes in the pericardium, as well as, histopathological changes in the epimyocardium. Methods: A total of 10 Large White adult pigs underwent pacemaker implantation under general anesthesia. By using an anterolateral thoracotomy, leads were implanted under visual guidance in the left ventricle and in the right atrium through the transverse sinus. Pacing and sensing parameters, in unipolar and bipolar modes, were obtained during the intraoperative and immediate postoperative period and on the 7th and the 30th postoperative day. At the end of the study, all animals underwent reoperation by thoracotomy through a median longitudinal sternotomy for evaluation of pericardial adhesions and histopathological analysis of the junction between the lead and epimyocardial wall. Results: All animals were alive until the end of the study and there were no serious intraoperative complications. Pacing and sensing parameters for atrial and ventricular leads in both unipolar and bipolar modes remain stable throughout the study and showed similar performance. We observed a progressive increase in atrial thresholds, ranging from 0.50 ± 0.38 to 1.86 ± 1.31 volts, during the intraoperative and on the 30-day postoperative, respectively. Similar result was observed for ventricular thresholds, which ranged from 0.43 ± 0.23 volts, intraoperatively, to 1.22 ± 0.49 volts on the 30-day postoperative. Atrial and ventricular impedance measurements decreased slightly over time, and the atrial impedance ranged from 486.80 ± 126.35 to 385.0 ± 80.52 Ohms during the intraoperative and on the 30-day postoperative, respectively. Ventricular impedance ranged from 700.40 ± 203.67 Ohms, intraoperatively, to 409.30 ± 58.96 Ohms, on the 30-day postoperative. Both atrial and ventricular sensing measurements remain stable since the immediate postoperative period. Pericardial adhesions were found in all animals and in all studied regions. There was no noticeable pericardial effusion or myocardial constriction. Microscopic analysis showed that contact with the electrode had caused thickening of the right atrium, left ventricle and pulmonary artery. Similar scar formation was found at the interface between atrial lead and epimyocardial, such as ventricular lead and epimyocardial. Conclusion: Implantation of the right atrial lead through the transverse sinus was safe and reproducible. The effectiveness of the procedure was confirmed by stable conditions of pacing and sensing parameters throughout the postoperative follow-up. Pericardial adhesion was the only change found in the pericardial morphology. There was adequate scar formation between the interface of atrial lead and the epimyocardial
|
Page generated in 0.0704 seconds