• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 311
  • 40
  • 40
  • 39
  • 39
  • 24
  • 16
  • 6
  • 6
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 314
  • 314
  • 99
  • 73
  • 56
  • 46
  • 40
  • 39
  • 35
  • 35
  • 34
  • 34
  • 33
  • 32
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Preparação e caracterização de ligas do sistema Ti-Mo contendo oxigênio intersticial para aplicações biomédicas

Nogueira, Renata Abdallah [UNESP] 19 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-19Bitstream added on 2014-06-13T19:06:01Z : No. of bitstreams: 1 nogueira_ra_dr_bauru.pdf: 4832696 bytes, checksum: e9a20c5603fd561629f155a1c301899e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Titânio e suas ligas são empregados em aplicações biomédias, pois possuem excelente biocompatibilidade com o organismo humano, uma excelente resistência à corrosão em meio biológico além de uma ótima resistência mecânica/densidade. Diversas propriedades do titânio comercialmente puro podem ser melhoradas com a adição de elementos substitucionais e intersticiais, e por técnicas de processamentos termomecânicos. o objetivo neste trabalho foi estudar o efeito de oxigênio intersticial presente em ligas do sistema binário. Ti-Mo (5-20% em peso de Mo) em seu comportamento mecânico utilizando ensaios de dureza, módulo de elasticidade dinâmico e ensaio de tração, em cinco condições de estudo: após o forjamento rotativo a quente, tratamento térmico e após dopagem com oxigênio, com três diferentes teores deste elemento. As amostras foram preparadas em forno a arco e caracterizadas por medidas de composição química, análise de gases, difração de raios X, microscopia óptica e eletrônica de varredura, espectroscopia por energia dispersiva e medidas de densidade. Após as dopagens com oxigênio, observou-se um aumento na dureza da liga Ti-5Mo devido ao aumento na fração volumétrica da fase a'. Para a liga Ti-10Mo, os valores após as dopagens permaneceram próximos à condição após tratamento térmico, não ocorrendo variações expressivas. Para as ligas Ti-15Mo, verificou-se uma diminuição na dureza provavelmente devido ao resfriamento rápido realizado após as dopagens com oxigênio. Os valores do módulo de elasticidade da liga Ti-5Mo aumentaram com o aumento da concentração de oxigênio, pois ocorreu um aumento na fração volumétrica da fase a'. Com relação aos valores de módulo de elasticidade da liga Ti-10Mo, não se observam variações significativas devido à adição de oxigênio. Para as ligas... / Titanium and its alloys are used in biomedical applications because they have excellent biocompatibility with human organisms, an excellent corrosion resistance in biological mediums, and great mechanical strength/density. Several properties of commercially pure titanium can be improved by the addition of interstitial and substitutional elements or by thermo-mechanical processing techniques. The purpose of this work is to study the effect of interstitial oxygen present in binary Ti-Mo systemj alloys (5-20% in weight of Mo) on its mechanical behavior, using hardness testing, dynamic elasticity modulus and tensile test on five conditions: after swaging, after heat treatment, and after oxygen doping, with three different levels of this element. The samples were prepared in an arcmelting furnace and were characterized by measures of chemical composition, gas analysis, x-ray diffraction, electron and optical microscopy, energy dispersive spectroscopy, and density measurements. After the doping with oxygen an increase in hardness of the Ti-5Mo alloy due to the increased volumetric fraction of a' phase was observed. For the Ti-10Mo alloy, the values after the doping were similar to those after heat treatment, and no expressive variations occurred. For the Ti-15Mo and Ti-20Mo alloys, there was a decline in hardness, probably due to rapid cooling after the doping with oxygen. The values of the elasticity modulus Ti-5Mo alloy increased with increasing oxygen concentration, because ther was an increase in the volumetric fraction of a' phase. With respect to the values of elasticity modulus of the Ti-10Mo alloy, no significant variations due to the addition of oxygen were observed. For the Ti15Mo and Ti-20Mo alloys, the introduction of oxygen decreased the elasticity modulus, because, with the increase in distance between the atoms, there was... (Complete abstract click electronic access below)
192

Análise da rota de processamento da liga Ti-30T visando a aplicação biomédica

Konatu, Reginaldo Toshihiro [UNESP] 21 January 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-21Bitstream added on 2014-06-13T19:14:21Z : No. of bitstreams: 1 000734240.pdf: 3500880 bytes, checksum: e67bece11d8f988c7d185ae81ec42a2d (MD5) / Ligas de titânio são utilizadas para aplicações biomédicas devido as excelentes propriedades como a alta resistência à corrosão, biocompatibilidade e propriedades mecânicas. No presente trabalho, foram analisadas as microestruturase as propriedades mecânicas daliga Ti-30Ta e em amostras deformadas com diferentes graus de compressão. A liga foi obtida pela fusão dos metais puros em um forno a arcovoltaico com atmosfera inerte de argônio. O material obtido foi homogeneizado em um forno tubular a 1000 °C por 24 h e deformadas a friopelo processodeforjamento rotativo para obter barras de 13 mm de diâmetro. A liga foi avaliada utilizadastécnicas de difração de raios-X (DRX) em temperatura ambiente e com aquecimento, calorimetria diferencial de varredura(DSC), microscopia eletrônica de transmissão (TEM), microdureza e compressão de corpos de provas em diferentes graus de deformação. As amostras foram deformadas com taxas graus de 19%, 22% e 43% e analisadas, usando as técnicas de DRX,microscopia óptica, microdureza. A liga apresentou transformação alotrópica a uma temperatura próxima de 650°C, e microestrutura do tipo α'', a deformação da amostra resultou em cisalhamento na amostra de 43%, as amostras apresentaram microdureza de 250, 269, 286 e 280HV para as amostras sem deformação, 19%, 22%e 43% de deformação / Titanium and its alloys have been used for biomedical applications due their excellent properties, such as high corrosion resistance, biocompatibility and mechanical proprieties. In this work, the microstructure and mechanical proprieties of Ti-30Taand deformeds amples with different degrees of compression were analyzed The in gots were obtained in a arc melting furnace inan argon atmosphere. In gots were homogenized at 1000 ºCin a tubular furnace with argon atmosphere for 24 hours and than they were cold worked by swaging. and samples with 13 m mindiameter were obtained. The alloy was evaluated by X-raydiffraction (XRD), Heat treatment X ray diffraction (HTXRD)and differential scanning calorimetrical (DSC), transmission electron microscopy(TEM), micro hard nessand compression test with different deformations. The samples were forging at reductionratiosof 19%, 22% and 43%. After this deformation,its microstructure were evaluated by optical microscopy, X-ray diffraction(XRD)and micro hardness in each condition. The alloy show a allotropic transformation at 650 °C, and α'' microstructure. The sample that was compressed with 43% shear and the others samples ( 19%, 22%) don´t change their microstructure. the samples without deformation, 19%, 22% and 43% result 250, 269, 286, 280 HV
193

Processamento e caracterização mecânica da liga à base de titânio (Ti-7,5Mo) para confecção de prótese ortopédica

Corrêa, Maria Emilia Cavalca [UNESP] 20 January 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-20Bitstream added on 2014-06-13T19:55:25Z : No. of bitstreams: 1 000755466.pdf: 1900630 bytes, checksum: 11facf52f6b2aee9fd218c8256725d0f (MD5) / Nos últimos anos, o aumento da qualidade de vida e o envelhecimento da população, resultou no estudo de novos materiais para aplicações ortopédicas. Biomateriais metálicos, como o titânio e suas ligas, têm sido utilizados devido as suas excelentes propriedades mecânicas e biocompatibilidade. Neste estudo, a viabilidade do uso da liga Ti-7.5Mo na substituição do tecido duro foi avaliada. Os lingotes de liga de Ti-7.5Mo foram fundidos em forno a arco sob atmosfera controlada. Corpos de prova foram usinados a partir de barras obtidas por forjamento rotativo após tratamento térmico. Ensaios de compressão e fadiga foram avaliados para se obter as propriedades mecânicas. Também foi realizada a análise microestrutural (DRX e microscopia óptica). Os resultados obtidos demonstram grande possibilidade da utilização desta liga para aplicações na confecção de implantes de carga como a prótese de quadril / In the last years, the increase of the of life expectancy and aging of the population has resulted in the study of new materials for biomedical applications. Metallic biomaterials, such as titanium and its alloys, have been used due their excellent properties such biocompatibility. In this study, the viability of the use Ti-7.5Mo alloy in the replacing of the hard tissue was evaluated. Ingots of the Ti-7.5Mo alloy were obtained in arc melting furnace with inert atmosphere. Bars were obtained after heat treatment and cold work by swaging. Compression,tension test and fatigue tests were use for evaluated the mechanical properties. Also microsctructural analysis was realized by using XRD and optical microscopy. Experiments results indicate that Ti-7.5Mo alloy have Young modulus (65 GPa) lower than other commercial alloys and titanium commercially pure. Alloy exhibited higher ratio strength-to–modulus ratio this property is very interesting for biomedical applications. Processing influenced the performance of the alloy during compression test. Analysis of the results shows the potential of this alloy for biomedical applications due their excellent behavior
194

Estudo do comportamento em fadiga da liga Ti30Ta após tratamento alcalino e térmico : aplicações biomédicas /

Silva, Kerolene Barboza da. January 2017 (has links)
Orientador: Valdir Alves Guimarães / Banca: Marcelino Pereira do Nascimento / Maria Ismênia Sodero Toledo / Resumo: Titânio e suas ligas são considerados muito importantes na área médica devido a sua excelente biocompatibilidade e propriedades mecânicas. Nos últimos anos as superfícies dos implantes têm sido estudadas com o objetivo de melhorar suas respostas ósseas, levando há uma tendência de provocar alterações superficiais a fim de acelerar o processo de osseointegração. O tratamento alcalino e térmico é um método típico de modificação da superfície responsável pelo surgimento de uma camada microporosa de óxidos bioativos. No entanto, é importante lembrar que os implantes trabalham sob a ação de carregamentos mecânicos complexos e que, em várias situações, é bastante comum a ocorrência de falhas por fadiga. Visto que, a superfície do implante está sujeita a maiores solicitações que qualquer outra parte, suas características são muito importantes. O objetivo principal da presente pesquisa é estudar a influência da alteração de superfície, por meio da realização do tratamento alcalino e térmico, no comportamento em fadiga da liga Ti30Ta. O trabalho foi iniciado com a fusão dos elementos da liga em forno a arco voltaico em atmosfera de argônio, seguido de tratamento térmico e forjamento rotativo. Para o estudo de fadiga foram confeccionados corpos de provas padrão. A modificação da superfície foi realizada por meio do tratamento alcalino empregando-se solução de NaOH 1,5 M e tratamento térmico. Posteriormente, os corpos de prova foram ensaiados em fadiga. A caracterização utilizou técnic... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and its alloys are considered very important in the medical area because their excellent biocompatibility and mechanical properties. In recent years surfaces implant have been studied with the goal of improving their bone answers, leading to a tendency to cause superficial changes through the action of chemicals products in order to accelerate the osseointegration process. Alkaline and heat treatment is a typical method of surface modification by surface deposition of bioactive oxides with a porous surface. However it is important to remember that the implants work under the action of complex mechanical loads and the occurrence of failures due to fatigue is quite common in many situations. Since the surface implant is subject to greater demands than any other part, its characteristics are very important. The main goal of this research is to study the influence of modification surface on the fatigue behavior of the Ti30Ta alloy. This work was started with the experimental alloy obtained by melting of the elements in a voltaic arc furnace, heat treatment and cold work. For the fatigue study were prepared specimens. The surface modification was carried out by alkaline treatment using NaOH solution 1,5 M and heat treatment. Later, the specimens were tested in fatigue. The characterization was performed using optical microscopy, scanning electron microscopy, X - ray diffraction, roughness and contact angle. The results obtained suggested that surface modification didn't a... (Complete abstract click electronic access below) / Mestre
195

Membranas híbridas do tipo ureasil-poliéter contendo peptídeo de crescimento ósseo para técnica de regeneração óssea guiada /

Oshiro Junior, João Augusto. January 2017 (has links)
Orientador: Leila Aparecida Chiavacci / Coorientador: Rosemary Adriana Chierici Marcantonio / Banca: Eduardo Ferreira Molina / Banca: Luis Carlos Spolidorio / Banca: Marlus Chorilli / Banca: Luís Geraldo Vaz / Resumo: A técnica de Regeneração Óssea Guiada (ROG) auxilia a restauração do tecido ósseo impedindo a concorrência entre as células do tecido ósseo e as células dos tecidos moles pelo uso de membranas; entretanto, não existe no mercado uma membrana osteoindutora. O peptídeo de crescimento osteogênico (OGP) atua como estimulador hematopoiético, promovendo a diferenciação osteoblástica e é um bom candidato para ser incorporado em membranas. Sendo assim, o objetivo deste trabalho foi desenvolver membranas a partir de materiais híbridos contendo OGP para otimizar a ROG. Para o desenvolvimento das membranas, foram utilizadas misturas de três polímeros, sendo dois à base de polióxido de etileno (POE) de massa molecular 500 e 1900 g mol-1 e um à base de polióxido de propileno (POP) de massa molecular 400 g mol-1. Diferentes métodos de esterilização foram utilizados. A caracterização dos materiais foi realizada pelas técnicas de calorimetria exploratória diferencial (DSC), espalhamento de raios-x a baixo ângulo (SAXS), análise mecânica dinâmica (DMA), determinação do pH e microscopia de força atômica (MFA). O OGP foi sintetizado pelo método em fase sólida, purificado por HPLC e caracterizado por espectrometria de massas. Os resultados de esterilização revelaram que a radiação gama a 24 kGy não alterou a estrutura do material, confirmado pelo DSC. A técnica de SAXS revelou a homogeneidade estrutural da matriz, assim como, a nano distância entre os entre os "nós" de silício. Os resultados de D... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The Guided Bone Regeneration (GBR) technique helps to restore bone tissue through the principle of cellular selectivity, i.e., excluding the epithelium and connective tissues from the damaged area by the use of membranes; However, there is no osteoinductive membrane on the market. The osteogenic growth peptide (OGP) acts as a hematopoietic stimulator, promoting osteoblastic differentiation and is a good candidate to incorporated into membranes. Therefore, the objective of this work was to develop membranes from hybrid materials containing OGP to optimize GBR. For development of the membranes, blends of three polymers were used, being two poly oxide ethylene (POE) of molecular weight 500 and 1900 g mol-1 and one based on poly oxide propylene (POP) of molecular mass 400 g Mol-1. Different methods of sterilization were used. The characterization of the materials was performed by differential scanning calorimetry (DSC), small angle x-ray scattering (SAXS), dynamic mechanical analysis (DMA), pH determination and atomic force microscopy (AFM). OGP was synthesized by the solid phase method, purified by HPLC and characterized by mass spectrometry. Sterilization results revealed that gamma radiation at 24 kGy did not change the structure of the material, as confirmed by the DSC. The SAXS technique revealed the structural homogeneity of the matrix, as well as the nano distance between the "nodes" of silicon. The DMA results showed that the membranes were not ruptured when submitted to ... (Complete abstract click electronic access below) / Doutor
196

Avaliação de úlceras de córnea complicadas em cães, tratadas com a membrana de poli(butileno adipato-cotereftalato) (PBAT) e amido termoplástico (TPS) /

Rodrigues, Giovanna Giuffrida January 2017 (has links)
Orientador: Alexandre Lima de Andrade / Banca: Flávia de Rezende Eugênio / Banca: Natalie Bertelis Merlini / Resumo: A ceratite ulcerativa é uma condição comum e importante e ocorre quando o epitélio e uma quantidade variável de estroma são perdidos. Atualmente, tem-se estudado o emprego de membrana de polímeros sintéticos, para reparação tectônica, em substituição aos tecidos biológicos. O presente trabalho teve como objetivo avaliar o tratamento, por ceratoplastia lamelar com o uso da membrana de Poli(butileno adipato-co-tereftalato) (PBAT) / Amido Termoplástico (TPS), de úlceras de córnea de seis cães da rotina clínica. Foram avaliados os aspectos clínicos quanto a: blefarospasmo, hiperemia conjuntival, secreção ocular, vascularização corneal, e sinais de extrusão da membrana aos terceiro, sétimo, décimo quinto e trigésimo dias de posoperatório (M3, M7, M15, M30). Com os valores obtidos, foi realizada análise descritiva dos resultados, com cálculo de porcentagem e mediana dos dados e escores adotados. Quanto ao blefarospasmo, este foi leve até M3, tornando-se ausente em M30. A secreção ocular esteve sob forma leve até o M7 e se tornou ausente até o M30. Com relação à hiperemia conjuntival, observou-se que foi intensa no M0 e regrediu temporalmente até M15. A vascularização corneal teve importância clínica a partir de M7, tornando-se intensa no M15 e moderada no M30. Após remoção da membrana, observou-se cicatrização corneal e manutenção da estrutura do bulbo do olho. Com base nos resultados obtidos e nas condições aqui estabelecidas, é possível concluir que a membrana de PBAT/TPS consti... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: - Ulcerative keratitis or corneal ulcer is a common and important condition and occurs when the epithelium and a variable amount of stroma are lost. Nowadays, the use of synthetic polymer membranes has been studied for tectonic repair, replacing biological tissues. The aim of this study was to evaluate the treatment of corneal ulcers of six dogs from clinical routine by interlamellar keratoplasty with Poly(butylene adipate-co-terephthalate) (PBAT) / Thermoplastic Starch (TPS) membranes. The clinical aspects regarding blepharospasm, conjunctival hyperemia, ocular secretion, corneal vascularization, and membrane extrusion signals at third, seventh, fifteenth and thirtieth postoperative days (M3, M7, M15, M30) were evaluated. With the obtained data a descriptive analysis of the results was performed, with calculation of percentage and median of the data and adopted scores. As for blepharospasm, it was mild to M3, becoming absent in M30. The ocular secretion, was in light form until the M7, and became absent until the M30. Conjunctival hyperemia was observed to be intense in M0 and regressed temporarily to M15. The corneal vascularization had clinical importance from M7, becoming intense in M15 and moderate in M30. After removal of the membrane, corneal healing was observed, and the structure of the eye bulb was maintained. Based on the results obtained and the conditions established herein, it is possible to conclude that the PBAT / TPS membrane is a viable alternative to lamellar keratoplasty / Mestre
197

Efeito do gluconato de cálcio em blendas poliméricas sericina / álcool poli (vinílico) / Effect of calcium gluconate on sericin/poly (vinyl alcohol) polymer blends

Gamero, Patricia Dias 29 May 2017 (has links)
A pesquisa e o desenvolvimento de novas tecnologias na área de materiais e de processos químicos tem sido objeto de muitos trabalhos científicos que buscam inovações. O uso de materiais poliméricos para aplicação na área biomédica está em constante ascensão, e possuem importantes aplicações como sistema controlado de liberação de drogas, encapsulamento de células, regeneração de tecidos musculares e blendas para uso tópico. Os polímeros podem ser sintéticos como os álcool poli (vinílico)(PVA) e naturais também chamados de biopolímeros como a sericina (SER) formada pelo Bombyx mori. Para a utilização de biopolímeros é extremamente importante à avaliação de algumas características como dos agentes plastificantes e/ou reticulantes, a fim de, produzir blendas com melhores propriedades ao fim destinado. Dentro desse contexto, o estudo teve como objetivo avaliar o efeito do gluconato de cálcio (GLU) em blendas poliméricas SER/PVA visando uma possível aplicação em materiais com liberação controlada de fármacos, elaborar filmes poliméricos da blenda SER/PVA com glicerol (GLI) e gluconato de cálcio e composições e caracterizar sistemas esses filmes quanto ao teor de umidade, espectroscopia no infravermelho em módulo de refletância total atenuada com transformada de Fourier, análises termogravimétrica, microscopia eletrônica de varredura, ensaios de tração e monitorar o teor de cálcio em solução proveniente da liberação do gluconato de cálcio presente nos filmes da blenda SER/PVA por espectroscopia de absorção atômica. Observou-se maior estabilidade térmica nos filmes com GLU como aditivo devido ao seu possível efeito reticulante relacionado aos íons Ca2+ presentes na blenda, com teor de umidade maior quando a GLY é utilizada, Nos estudos de FTIR-ATR pode ser observado que o GLU causa alteração do perfil espectroscópico do filme entre 50% e 60% do teor de SER diferentemente do que ocorre com a GLY (40% - 50%) Nos estudos de morfologia observou-se uma separação de fase em ambos os filmes com GLY e GLU, nos resultados de tração o GLY apresentou a plasticidade esperada já o GLU elimina a plasticidade do filme SER/PVA porém aumento significativamente a resistência do material, consequência clara de interações mais intensas no interior do material. Apresentou também um perfil de liberação positivo que pode ser modulado em composições de SER/PVA, esses resultados demonstram a viabilidade do filme como um material de liberação. Assim o GLU possui uma função múltipla na blenda polimérica proposta além de atuar como reticulante também pode atuar como fármaco. / The research and development of new technologies in the field of chemical materials and processes has been the subject of many scientific works that seek innovations. The use of polymer materials for application in the biomedical area is constantly increasing, and they have important applications as controlled system of drug release, cell encapsulation, regeneration of muscle tissues and blends for topical use. The polymers may be synthetic such as poly (vinyl alcohol) (PVA) and natural also called biopolymers such as sericin (SER) formed by Bombyx mori. For the use of biopolymers it is extremely important to evaluate some characteristics such as plasticizers and / or crosslinking agents in order to produce blends with better properties to the intended purpose. The objective of this study was to evaluate the effect of calcium gluconate (GLU) on SER / PVA polymer blends aiming at a possible application in materials with controlled release of drugs, to prepare SER / PVA polymer blends with glycerol (GLI) And calcium gluconate and compositions and characterize systems such films for moisture content, infrared spectroscopy in Fourier transform attenuated total reflectance module, thermogravimetric analysis, scanning electron microscopy, tensile tests and monitor calcium content in solution Resulting from the release of the calcium gluconate present in the SER / PVA blends films by atomic absorption spectroscopy. It was observed higher thermal stability in GLU films as an additive due to its possible crosslinking effect related to the Ca2+ ions present in the blends, with a higher moisture content when GLY is used. In the FTIR-ATR studies it can be observed that GLU causes Alteration of the spectroscopic profile of the film between 50% and 60% of the SER content differently than occurs with GLY (40% - 50%) In the morphology studies a phase separation was observed in both GLY and GLU films, In the traction results the GLY presented the expected plasticity since the GLU eliminates the plasticity of the SER / PVA film but significantly increases the resistance of the material, a clear consequence of more intense interactions inside the material. It also showed a positive release profile that can be modulated in SER / PVA compositions, these results demonstrating the viability of the film as a release material. Thus, GLU has a multiple function in the proposed polymer blend as well as acting as a crosslinker can also act as a drug.
198

Estudo de tratamentos térmicos da liga Ti-15Zr-xMo /

Xavier, Caio Castanho. January 2017 (has links)
Orientador: Luís Augusto Sousa Marques da Rocha / Banca: Conrado Ramos Moreira Afonso / Banca: Carlos Roberto Grandini / Resumo: O titânio, e as ligas baseadas nesse elemento, são amplamente utilizados como biomateriais, com aplicações tanto como implantes dentários quanto ortopédicos. Para isso, apresentam características importantes como: biocompatibilidade, resistência à corrosão, em geral baixo módulo de elasticidade e baixa densidade. O titânio possui uma temperatura de transformação alotrópica, que propicia o controle das propriedades da liga pela manipulação de sua microestrutura, através da adição de elementos de liga e/ou tratamentos térmicos. De fato, para ligas de titânio com uma composição definida, a realização de tratamentos térmicos, permite modificar a microestrutura da liga e, consequentemente, modificar as propriedades mecânicas do material em questão, fator essencial para o estudo em aplicações como um implante médico. O presente trabalho tem como objetivo o estudo detalhado de diferentes tipos de tratamentos térmicos de ligas do sistema Ti-Zr-Mo. Diferente de outros trabalhos da literatura, o estudo foi feito para cada tratamento térmico separadamente, analisando a microestrutura e a microdureza das ligas visando uma aplicação biomédica. Primeiramente, as ligas foram fundidas em um forno de fusão à arco voltaico, com quatro composições diferentes de liga: Ti-15Zr, Ti-15Zr-5Mo, Ti-15Zr-10Mo e Ti-15Zr-15Mo. Dessa maneira, pretendeu-se obter amostras com microestruturas de fase α, α+β e β. Através de uma análise por EDS, um estudo sobre a composição química das amostras foi realizado, ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The element titanium and its alloys are widely used as biomaterials with applications in both dental implants as in orthopedics materials. Therefore, important features are required such as: biocompatibility, corrosion resistance, low values of Young modulus and low density. Also, titanium has an allotropic transformation temperature, which provides controlling the mechanical properties of the alloy. A microstructure manipulation can be achieved by the addition of certain alloying elements and heat treatments. In fact, for titanium alloys with a defined composition, heat treatments allow microstructure modification, hence alteration in the mechanical properties of the material, an essential subject for the study of medical implants applications. This study provides a detailed study of heat treatment conditions in a Ti-Zr-Mo system alloy. Unlike other papers in the literature, this study was done for each heat treatment separately, analyzing the microstructure and microhardness of the alloys for a biomedical application. First, the alloys were melted in an arc voltaic furnace, with four different alloys compositions: Ti-15Zr, Ti-15Zr-5Mo, Ti-15Zr-10Mo and Ti-15Zr-15Mo. In order to obtain samples with α, α+β and β phase microstructures. Through EDS analysis, a study on the chemical composition of the samples was performed. It was determined that the alloys were cast with good quality and without the presence of agglomerates or segregates. Microstructural analysis with optical m... (Complete abstract click electronic access below) / Mestre
199

Estudo da biocompatibilidade e tempo de degradação do vitrocerâmico de anortita / Luciana Biancchi Bond Honaiser ; orientadora, Beatriz Luci Fernandes ; co-orientador, Etney Neves

Honaiser, Luciana Biacchi Bond January 2005 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2005 / Bibliografia: f. 71-72 / As placas de Aço Inoxidável Austenítico são utilizadas para redução de fraturas, pois são especificadas pelas normas ASTM e ISO como resistentes e biocompatíveis. Apesar de especificadas o paciente deveria retornar para a remoção do implante após a consol / The 304 Austenitic Stainless Steel plates are used for reduction of bone fractures, since they are specified by ASTM and ISO standards as resistant and biocompatible. The patient would have to return for the removal of the plate after fracture consolidati
200

Estudo da localização e acúmulo de partículas metálicas em orgãos de ratos / Silvia Helena Gierts ; orientador, Beatriz Luci Fernandes

Gierts, Silvia Helena January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: f. 49-53 / A maioria das próteses, como as de quadril, joelho, ombro, parafusos, pinos e hastes de fixação, é confeccionada em ligas de titânio, ligas de cobalto e em aços inoxidáveis austeníticos. A liberação de partículas metálicas ou íons metálicos a partir de um / The majority of the prosthesis like those for hip, knee, shoulder, screws, bolts and stems, is produced with Ti alloys, Co alloys and austenitic stainless steel. The release of metallic particles or metallic ions from an endoprosthesis can occur due to co

Page generated in 0.0896 seconds