• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 311
  • 40
  • 40
  • 39
  • 39
  • 24
  • 16
  • 6
  • 6
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 314
  • 314
  • 99
  • 73
  • 56
  • 46
  • 40
  • 39
  • 35
  • 35
  • 34
  • 34
  • 33
  • 32
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Avaliação do reparo ósseo de defeitos de tamanho crítico tratados com matriz óssea mineralizada de osso bovino (Bio-Oss®) e laser de baixa intensidade. Estudo histomorfométrico e imunohistoquímico em ratos /

Torquato, Letícia Cavassini January 2020 (has links)
Orientador: Andréa Carvalho [Unesp] De Marco / Resumo: Este estudo teve como objetivo investigar os efeitos da terapia com laser de baixa intensidade (LLLT) associada ao Bio-Oss® em defeitos de tamanho crítico de ratos. Foram utilizados 72 ratos machos adultos (Rattus norvegicus, variação albinus, Wistar), com 90 dias de idade. Foram realizados defeitos ósseos na calvária com 5 mm de diâmetro. Os animais foram divididos em 4 grupos: C-Coágulo sanguíneo, B- Bio-Oss®, L- LLLT, B+L- Bio-Oss® + LLLT. Cada grupo foi subdividido de acordo com os períodos de observação de 07, 30 e 60 dias, com 6 ratos em cada subgrupo. Para LLLT uma baixa energia GaAlAs com comprimento de onda de 660 nm, foi aplicada em 5 pontos. Foram distribuídos 4 pontos de aplicação ao longo das bordas da ferida e um ponto de aplicação localizado na região central da ferida cirúrgica. A irradiação foi liberada por 12 segundos por ponto, com uma densidade total de energia de 45 J/cm2. A irradiação com laser ocorreu de forma transcirurgica em única aplicação imediatamente após o procedimento. Em 07, 30 e em 60 dias, 6 animais de cada grupo foram eutanasiados pela aplicação de anestesia geral em dose triplicada, e após os testes de sensibilidade os animais foram decapitados. Em seguida a calvária foi removida para análises histomorfométrica e imunohistoquímica. Todos os dados histomorfométricos foram submetidos a análise por ANOVA, complementado pelo teste de Tukey. O nível de significância foi de 5%. Os resultados da imunohistoquímica foram representados por scores e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to investigate the effects of low-level laser therapy (LLLT) associated with Bio-Oss® on critical size defects in rats. 72 adult male rats (Rattus norvegicus, variation albinus, Wistar), 90 days old, were used. Bone defects were made in the calvaria with a diameter of 5 mm. The animals were divided into 4 groups: C-blood clot, B-Bio-Oss®, L-LLLT, B + L- Bio-Oss® + LLLT. Each group was subdivided according to the observation periods of 07, 30 and 60 days, with 6 rats in each subgroup. For LLLT a low GaAlAs energy with a wavelength of 660 nm was applied at 5 points. 4 points of application were distributed along the edges of the wound and one point of application located in the central region of the surgical wound. The irradiation was released for 12 seconds per point, with a total energy density of 45 J/cm2. Laser irradiation occurred in a trans-surgical form in a single application immediately after the procedure. At 07, 30 and 60 days, 6 animals from each group were euthanized by applying triple dose of general anesthesia, after the sensitivity tests the animals were beheaded. Then the calvaria was removed for histomorphometric and immunohistochemistry analysis. All histomorphometric data were analyzed statistically by ANOVA, complemented by the Tukey test. The level of significance was 5%. The results of immunohistochemistry were represented by scores and percentage. The groups that showed the highest proportion of neoformation were groups L (0,39±0,13) and... (Complete abstract click electronic access below) / Mestre
172

Osseointegração de implantes com diferentes macro e microestruturas instalados em áreas sem enxertia ou com osso bovino desproteinizado associado ou não à medula óssea fresca : estudo pré-clínico em coelhos /

Leocádio, Amanda de Carvalho Silva January 2020 (has links)
Orientador: Elcio Marcantonio Junior / Resumo: Implantes com diferentes macro (CI-Implante Cilíndrico e HCI-Implante Cônico Híbrido) e microestruturas (NP-Jateamento+ataque ácido e AQ-Jateamento+ataque ácido+imersão em solução isotônica de cloreto de sódio 0,9 %) foram testados em áreas de osso nativo ou enxertadas prévia ou imediatamente com osso bovino desproteinizado associado ou não à medula óssea fresca (DBB e DBB/BM). Na primeira hipótese foi testado a estabilidade primária e o processo de osseointegração em implantes com diferentes macroestruturas (CI vs. HCI) na metáfise tibial de coelhos. 24 coelhos foram divididos em 3 períodos (2, 4 e 8 semanas). Cada animal recebeu bilateralmente 2 implantes de cada grupo. Todos os implantes foram avaliados quanto ao torque de inserção. Um dos implantes foi submetido ao torque de remoção e análise histológica e o outro foi utilizado para análise microtomográfica e histométrica (%BIC-Contato Osso-Implante). Os HCI apresentaram maior torque de inserção (32.93±10.61 Ncm vs. 27.99± 7.80Ncm) e maior %BIC no período de 8 semanas (79.08±11.31% vs. 59.72±11.29%) que CI. CI apresentaram maiores valores de torque de remoção que HCI no período de 8 semanas (91.05 ± 9.32 Ncm vs. 68.62 ± 13.70 Ncm). Não houve diferenças em relação aos dados microtomográficos. Na segunda e na terceira hipóteses, foi avaliado a influência de diferentes macros (CI vs. HCI) e microestruturas de implantes (NP vs. AQ) no processo de osseointegração em áreas previamente (metáfise tibial e seio maxilar) ou imediat... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
173

Acidentes ocupacionais com material biológico : a per- cepção do profissional acidentado. / Occupational accidents with biological materials: the injured professional s perception.

DAMACENO, Ariadna Pires 21 March 2005 (has links)
Made available in DSpace on 2014-07-29T15:04:40Z (GMT). No. of bitstreams: 1 Ariadna Pires Damaceno.pdf: 389802 bytes, checksum: bf4fdc37f298b2522e379a3b088f5e0d (MD5) Previous issue date: 2005-03-21 / Occupational accidents involving biological materials may bring physical and psychological consequences to the injured professional Many workers commonly give less attention to such events not applying preventive steps as recommended for those procedures which represent risks to their health This paper aims at reporting the workers perception and undertanding on the context involving the accident with biological material including experimented feelings, reactions as well as actions taken The research has been done according to the presumptions of qualitative research and data was analysed in accordance with content analysis technique Data was collected by using questionnaires applied to health-care workers linked with a health care institution and later by an interview with the injured workers from an emergency and urgency reference unit in the city of Goiânia Firstly 382 health-care workers answered a questionnaire in order to identify those who had already suffered an accident 39 of those who had had an accident have participated in the interview concerning aspects related to the accidents The main causes to the accidents mentioned were: unattention non-adoption of preventive steps severity of injured patients hurry due to work overload and appliance structure and material-related deficiencies Among the feelings experimented we could highlight: insecurity fearing infection worries about the family rage and even calmness About half of the workers have reported that the accident had not brought any consequence into their lives The others reported that it had provided them with learning and growth All workers reported awareness of the risks related to the accident however we could note several inadequate conduct in their reports 18 professionals reported all the accidents they had 12 never reported any and 9 reported only those considered most serious Many manifested some difficulty in specifying the protective equipment used on the day of the accident mainly due to the amount of time from the day of the event to the research date The workers perception of such phenomenon is very different from one another regarding the same kind of accident Data shows the need of worker´s health self-valuing as well as programs aimed at improving the occupational safety / Os acidentes ocupacionais envolvendo material biológico podem trazer conseqüências físicas e psicológicas para o profissional acidentado Muitos profissionais costumam menosprezar esse tipo de acidente não adotando as medidas preventivas recomendadas para os procedimentos que representam riscos para sua saúde Nosso objetivo foi relatar a percepção e a compreensão dos profissionais acerca do contexto envolvido no acidente com material biológico incluindo os sentimentos experienciados reações e condutas adotadas A pesquisa foi desenvolvida dentro dos pressupostos da pesquisa qualitativa e os dados analisados de acordo com a técnica de análise de conteúdo Os dados foram coletados por meio de questionários aplicados aos profissionais de saúde vinculados a uma instituição de assistência a saúde posteriormente por meio de uma entrevista restrita aos profissionais acidentados de uma unidade de referência em atendimento de urgência e emergência da cidade de Goiânia Inicialmente 382 profissionais de saúde responderam a um questionário para identificar aqueles que tiveram algum acidente 39 dos profissionais acidentados participaram da entrevista abordando aspectos relacionados aos acidentes As principais causas mencionadas para os acidentes foram: descuido não adoção das medidas de prevenção gravidade dos pacientes atendidos pressa em função da sobrecarga de trabalho e deficiências relacionadas aos materiais equipamentos e estrutura Entre os sentimentos experienciados destacam: insegurança medo da infecção preocupação com a família raiva e até mesmo tranqüilidade Praticamente metade dos profissionais declarou que o acidente não trouxe nenhuma conseqüência para suas vidas os demais informaram que proporcionou aprendizagem e amadurecimento Todos os profissionais informaram ter conhecimento dos riscos relacionados aos acidentes embora identificadas várias condutas inadequadas nas exposições descritas 18 profissionais notificaram todos os acidentes sofridos 12 nunca os notificaram e 9 notificaram apenas os considerados mais graves Muitos manifestaram dificuldade em especificar os equipamentos de proteção utilizados no dia do acidente principalmente pelo tempo decorrido desde o fato até a data da pesquisa A percepção dos profissionais sobre este fenômeno é bastante diversificada considerando-se o mesmo tipo de acidente Os dados apontam para a necessidade de auto-valorização da saúde do trabalhador bem como de programas dirigidos para a melhoria da segurança ocupacional
174

Biocompatibilidade do biopolímero PLA e blenda PLA/PCL em ratos Wistar /

Conde, Gabriel January 2019 (has links)
Orientador: Guilherme de Camargo Ferraz / Resumo: A descoberta de polímeros biodegradáveis influenciou a pesquisa biomédica. O poli (ácido lático) (PLA) e a Poli (Ɛ-caprolactona) (PCL) e suas blendas se tornaram foco de vários estudos por serem biodegradáveis e biorreabsorvíveis, particularmente em pesquisas envolvendo a implantação in vivo. Pelo presente, objetivou-se avaliar se o implante subcutâneo (SC) e intraperitoneal (IP) de PLA ou blenda PLA/ PCL são seguros, biocompatíveis e biodegradáveis em ratos machos Wistar. Os ratos foram distribuídos em cinco grupos avaliados em duas fases; aguda: -1, 1, 2, 7 e 14 dias e crônica: 2, 8 e 24 semanas após a implantação. Assim, estudaram se os grupos PLA (PLA puro), PLA/PCL (mistura PLA/PCL), instrumentado (GI), controle (C) e grupo controle inflamatório (CI). Para avaliar a biocompatibilidade utilizou-se teste comportamental de campo aberto (CA), filamentos de von Frey (FvF) e análises histopatológicas utilizando coloração de hematoxilina-eosina (HE) e picrosirius-hematoxilina (PSH). A biodegradação in vivo e degradação in vitro em solução de PBS a 37°C do PLA e PLA/PCL foram avaliadas por microscopia eletrônica de varredura (MEV). As comparações foram realizadas entre os grupos subdivididos conforme a implantação IP e SC. No teste CA, realizado dois dias após a implantação, o grupo CI demonstrou redução nas frequências de locomoção e levantar e aumento na frequência de grooming em relação aos grupos implantados PLA, PLA/PCL, GI pela via IP ou SC e grupo C. As avaliações de FvF ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The discovery of biodegradable polymers influenced biomedical research. Poly (lactic acid) (PLA) and poly (Ɛ-caprolactone) (PCL) and their blends have become the focus of several studies because they are biodegradable and bioreabsorbable, particularly in research involving implantation in vivo. The aim of this study was to evaluate whether the subcutaneous (SC) and intraperitoneal (IP) implantation of PLA or PLA / PCL blends are safe, biocompatible and biodegradable in male Wistar rats. The rats were distributed in five groups evaluated in two phases; acute: -1, 1, 2, 7 and 14 days and chronic: 2, 8 and 24 weeks after implantation. Thus, we studied whether the groups PLA (pure PLA), PLA / PCL (PLA / PCL mixture), sham (S), control (C) and inflammatory control group (IC). To evaluate the biocompatibility, the open field behavioral test (OF), von Frey filaments (FvF) and histopathological analyzes using hematoxylin-eosin (HE) staining and picrosirius-hematoxylin (PSH) were used. In vivo biodegradation and degradation in vitro in PBS solution at 37°C of PLA and PLA / PCL were evaluated by scanning electron microscopy (SEM). The comparisons were made between groups subdivided according to the IP and SC implementation. In the OF test, performed two days after implantation, the IC group demonstrated a reduction in the locomotion frequencies and augmentation and increase in the grooming frequency in relation to the PLA, PLA / PCL, sham implanted groups via IP or SC and C groups. FvF... (Complete abstract click electronic access below) / Mestre
175

Selante heterólogo de fibrina como arcabouço para células tronco mesenquimais associados ao fosfato de cálcio e aplicados em defeito crítico de fêmures de ratos

Cassaro, Claudia Vilalva January 2018 (has links)
Orientador: Benedito Barraviera / Resumo: O reparo do tecido ósseo é um desafio antigo da ciência mundial. A partir das décadas de 70-80, os biomateriais passaram a ser explorados e hoje desempenham importante papel na engenharia tecidual. Estes, quando aplicados na enxertia óssea, devem ser bioativos, biocompatíveis e reabsorvíveis. A integração entre os diversos materiais de origem sintética e os arcabouços biológicos possui amplo espectro de uso. Dentre os arcabouços destacam-se os compostos à base de fibrina por suas propriedades hemostáticas, estabilidade e morfologia favorável à proliferação celular. A presente revisão abordou a estrutura e constituição do tecido ósseo e suas limitações no processo de reparo, a relevância da engenharia tecidual aplicada à esta finalidade e os biomateriais utilizados para otimizar tal processo, com ênfase especial aos materiais compostos por fosfatos de cálcio, células tronco mesenquimais e sua aplicação junto ao arcabouço biológico selante de fibrina, com destaque para o selante heterólogo de fibrina, agora denominado biopolímero de fibrina, um produto único e em fase de testes em experimentação animal e estudos clínicos. Propõe-se, ao final desta, uma nova abordagem para a regeneração de defeitos ósseos de ratos baseada na associação entre o selante heterólogo de fibrina, o fosfato de cálcio bifásico e células tronco mesenquimais. / Abstract: Bone tissue repair is an ancient challenge of world science. From the 70s and 80s, biomaterials began to be explored and nowadays play an important role in tissue engineering. These, when applied in bone grafting, have to be bioactive, biocompatible and resorbable. The integration between the various materials of synthetic origin and biological scaffolds has a wide spectrum of use. Among these scaffolds, fibrin-based compounds are distinguished by their hemostatic properties, stability and morphology favorable to cell proliferation. The present review addressed the structure and constitution of bone tissue and its limitations in the repair process, the relevance of tissue engineering approaches applied to this purpose and the biomaterials used to optimize this process, with special emphasis on materials composed of calcium phosphates, mesenchymal stem cells and its application with the biological sealant fibrin scaffold, highlighting the heterologous fibrin sealant, now named as fibrin biopolymer, a unique product testing in animal experimentation and clinical studies. At the end of this, a new approach is proposed for the regeneration of rat bone defects based on the association between heterologous fibrin sealant, biphasic calcium phosphate and mesenchymal stem cells. / Mestre
176

Síntese e caracterização de nanopartículas poliméricas para veiculação de lignanas bioativas /

Lima, Regiane Godoy de. January 2018 (has links)
Orientador: Rosangela da Silva de Laurentiz / Resumo: Os produtos naturais são uma fonte inesgotável de compostos químicos com as mais variadas propriedades biológicas, entretanto, muitos deles têm baixa biodisponibilidade e/ou são degradados pelas condições fisiológicas, o que os torna de pouco interesse para uso como potenciais fármacos. Dentre os vários produtos naturais bioativos as lignanas apresentam um significativo potencial citotóxico contra várias linhagens de células tumorais, como a (-)-hinoquinina (HNK), (-)-cubebina (CB) e (-)-6,6’-dinitrohinoquinina (DN), determinado em outros trabalhos. Entretanto, essa lignanas possuem caráter hidrofóbico e podem ser degradadas em condições fisiológicas dependendo do pH. Desta forma, o presente trabalho teve por objetivo estudar a incorporação dessas lignanas em nanopartículas poliméricas (NNPs), como forma de melhorar a biodisponibilidade, perdas por degradação e os efeitos da incorporação sobre a atividade citotóxica desses compostos. Neste estudo a HNK e CB foram extraídas da Piper cubeba e a DN foi sintetizada a partir da reação de nitração da HNK. Essa lignanas foram submetidas a ensaios de citotoxicidade contra as linhagens tumorais Hep-2 e Si-Ha. As NNPs com e sem a lignana foram sintetizadas utilizando como matriz polimérica inicialmente o PLGA (Poli(ácido lático-co-ácido glicólico). As NNPs sintetizadas foram caracterizadas quanto ao seu tamanho, morfologia e estabilidade utilizando análises de MEV, DSC, MET, UV/Vis, FTIR, DLS e potencial zeta. A eficiência da incorpora... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The natural products are inexhaustible source of chemical compounds with the most varied biological properties; however, many of them have low bioavailability and / or are degraded by physiological conditions, which makes them less interesting for use as potential drugs. Among the several bioactive natural products the lignans present a significant cytotoxic potential against several tumor cell lines, as (-)-hinokinin (HNK), (-)-cubebin (CB) and (-)-6,6’-dinitrohinokinin (DN), determined in previous works. However, these lignans have a hydrophobic character and can be degraded in physiological conditions depending on pH. Thus, the present work aimed to study the incorporation of these lignans into polymeric nanoparticles (PNPs), as a method to improve bioavailability, avoid losses by degradation and evaluate as this incorporation affects the its cytotoxic activity. In this study, the HNK and CB were extracted from Piper cubeba and the DN was synthesized from the nitration reaction of the HNK. These lignans were submitted to cytotoxicity assays against tumoral cells Hep-2 and Si-Ha. The empty and content lignans PLGA (Poly Lactic-co-Glycolic Acid, 65:35) PNPs were synthesized using the emulsion-evaporation methodology on mechanical agitation and dripping. The PNPs were investigated for their size, morphology and stability through SEM, DSC, TEM, UV/Vis, FTIR, DLS and zeta potential. Encapsulation efficiency incorporation of the lignan was determined by analysis of UV/Vis. In th... (Complete abstract click electronic access below) / Doutor
177

Potencial antimicrobiano e biocompatibilidade de óleos essenciais em associação a biomateriais à base de silicato tricálcico /

Castro Núñez, Gabriela Mariana. January 2020 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Os cimentos reparadores endodônticos à base de silicato de cálcio apresentam biocompatibilidade e bioatividade. Porém, sua ação antimicrobiana é limitada. O acréscimo de óleos essencias pode favorecer as propriedades antimicrobianas de materiais. Os óleos essenciais são substâncias de origem vegetal com propriedades antimicrobiana, antiviral, antifúngica, antitoxigênica, antiparasitária e inseticida. Este estudo teve como objetivo avaliar a associação de diferentes óleos essenciais nas propriedades físico-químicas, citocompatibilida, potencial bioativo e atividade antibiofilme dos cimentos reparadores à base de silicato de cálcio, MTA Repair HP (MTA HP) e Biodentine (BIO). Publicação 1: avaliou a associação de 1,5% de Farnesol (FAR). Publicação 2: analisou o acréscimo de 1% de Thyme Essential Oil (TEO). Publicação 3: associou 1% de lemongrass oil (LEO). As propriedades físico-químicas de tempo de presa, solubilidade após 7 dias de imersão em água destilada e pH em 1, 3, 7, 14 e 21 dias foram avaliadas. A citocompatibilidade foi avaliada por meio dos testes de methyltetrazolium (MTT) e Vermelho Neutro (VN) após exposição das células Saos-2 às diferentes diluições dos eluídos dos materiais por 24h. A bioatividade foi avaliada pela atividade enzimática da fosfatase alcalina (ALP) nos períodos de 1, 3 e 7 dias. Nódulos de mineralização foram também quantificados após 21 dias pela coloração com vermelho de Alizarina (ARS). A capacidade de inibição de Metaloproteinase de Matriz (MM... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
178

Desenvolvimento e estudo toxicológico em métodos alternativos dos compósitos à base de látex natural e fosfatos de cálcio para reparação óssea /

Miranda, Matheus Carlos Romeiro. January 2018 (has links)
Orientador: Rondinelli Donizetti Herculano / Coorientador: Eduardo Maffud Cilli / Coorientador: Ricardo José de Mendonça / Banca: Ana Maria Minarelli Gaspar / Banca: Ana Marisa Fusca Almeida / Banca: Antonio Carlos Shimano / Banca: Cecilia Amelia de Carvalho Zavaglia / Resumo: Com o aumento dos acidentes automotivos e da expectativa de vida e, consequentemente, o da população de idosos, as fraturas ósseas e a osteoporose estão mais recorrentes, incentivando assim, a busca por novos biomateriais para reparação óssea. Em vista desta problemática, o objetivo desse trabalho consistiu em estudar a influência de diferentes fases de fosfato de cálcio na liberação sustentada utilizando a membrana de latex natural (LN) como carreador para estimular a reparação óssea. Conforme os resultados de MEV/FEG, o sol-gel tratado à 400°C (CPP), 600°C (HA) e 1200°C (α-TCP), apresentaram partículas de 170-650nm, 110-620nm e 10-79nm, respectivamente. A análise de MEV/FEG da superfície das membranas apresentou partículas de CPP inclusas na superfície e no interior das membranas. No entanto, as membranas incorporadas com HA e a α-TCP apresentaram uma inclusão mais superficial. As análises DRX e FT-IR confirmaram a identidade das fases presentes nas membranas. A membrana de LN pura apresentou um valor de rugosidade 71 vezes menor que a amostra de maior rugosidade (LN+ HA). No ensaio de ângulo de contato, as amostras LN pura e LN + CPP apresentaram molhabilidade parcial, enquanto as membranas incorporadas com HA e α-TCP apresentaram molhabilidade completa. Nos ensaios de cinéticas das liberações, as membranas apresentaram uma liberação de 48% para CPP, 95% para HA e 71% para α-TCP durante 330 horas. O ensaio de atividade hemolítica apresentou 1,1% para LN pura, 0% para LN+CP... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The increase in car accidents and life expectancy, and consequently, elderly population, bone fractures and osteoporosis are more frequent, thus encouraging the search for new biomaterials for bone repair. In view of this problem, the objective of this work was to study the influence of different phases of calcium phosphate on sustained release using the natural latex (NL) membrane as carrier to stimulate bone regeneration. According to the FEG/SEM results, the sol-gel treated at 400°C (CPP), 600°C (HA) and 1200°C (α-TCP) had particles of 170-650nm, 110- 620nm and 10-79nm, respectively. FEG/SEM analysis of the membranes surface showed CPP particles included on the surface and inside the membranes. However, the incorporated membranes with HA and α-TCP had a more superficial inclusion. XRD and FT-IR analyzes confirmed the identity of the phases present in the membranes. The pure NL membrane presented a roughness value 71 times lower than the sample of greater roughness (NL + HA). In the contact angle test, the pure NL and NL + CPP samples showed partial wettability, while the incorporated membranes with HA and α-TCP showed complete wettability. In the release kinetics assays, the membranes showed a release of 48% for CPP, 95% for HA and 71% for α-TCP for 330 hours. The hemolytic activity assay presented 1.1% for pure NL, 0% for NL + CPP, 2.2% NL + HA and 1.1% for NL + α-TCP hemolysis. The cytotoxicity assay (MTT) in osteoblasts was inconclusive due enzymes contained in the late... (Complete abstract click electronic access below) / Doutor
179

Avaliação do comportamento mecânico e da microestrutura de duas marcas comerciais de zircônia monolítica 3Y-TZP sob influência de diferentes parâmetros de sinterização / Microstructural and mechanical evaluation of two commercial monolithic 3YTZP zirconia under various sintering conditions

Catramby, Marcela Ferraz 21 March 2014 (has links)
Cerâmicas a base de zircônia para coroas e próteses fixas monolíticas prometem suprimir a vulnerabilidade ao lascamento de restaurações de múltiplas camadas, proporcionando estética e resistência mecânica simultâneas. No entanto, é possível que as alterações realizadas para maximizar suas propriedades óticas possam afetar a resistência mecânica. O presente estudo teve por objetivo comparar, com base na microestrutura, o comportamento mecânico de duas marcas comerciais de zircônias monolíticas a uma zircônia convencional para infraestruturas, observando ao mesmo tempo algumas variações nos parâmetros de sinterização. As zircônias monolíticas ceramill Zolid e Prettau e a zircônia convencional IPS e.max ZirCAD foram sinterizadas sob a temperatura preconizada pelos respectivos fabricantes, formando os grupos Z1450, P1600 e I1530. Adicionalmente, foram criados os grupos Z1530 e Z1600, representados pela zircônia ceramill Zolid submetida a ciclos modificados. Foram confeccionados 13 corpos de prova para cada grupo, os quais foram submetidos aos ensaios de difração de raios-x, densidade, análise do tamanho médio de grão e resistência à flexão em 4 pontos. Os espectros de difração revelaram a presença da fase tetragonal metaestável em todos os grupos antes e após a sinterização. Quanto à densidade, apresentou-se superior a 99% apenas nos grupos formados pelas zircônias Prettau e IPS e.max ZirCAD. O tamanho médio dos grãos permaneceu abaixo de 1m em todas as situações, sendo maior para o grupo P1600 (0,814m) e menor para o grupo Z1450 (0,463m). Embora tenha sido observada uma tendência de melhoria nos resultados sob taxa de aquecimento mais lenta, os grupos formados pela zircônia monolíticas ceramill Zolid obtiveram os valores mais baixos de confiabilidade (m=4,58 para Z1530) e de resistência mecânica (621,01±138,08MPa para Z1450). A zircônia Prettau apresentou valores de resistência mecânica mais altos e homogêneos (864,18±118,21MPa), contudo inferiores aos da zircônia convencional (1057,41±150,54MPa). Os resultados revelam que as zircônias monolíticas sob estudo possuem características microestruturais e propriedades mecânicas distintas das observadas para a zircônia convencional. / Monolithic zirconia ceramics for crown and bridge applications were designed to eliminate chipping trends of bilayered restorations, providing both aesthetic and mechanical strength. Nonetheless, it has been suggested that improvements in optical properties may affect the mechanical strength of these materials. The present study aimed to compare, based on a microstructural analysis, the mechanical behavior of two commercial monolithic zirconia ceramics with a conventional core zirconia material, as well as to verify sintering parameters modifications. Two monolithic zirconia ceramics (Ceramill Zolid and Prettau) and a conventional core zirconia material (IPS e.max ZirCAD) were sintered according to manufacturer´s recommendations, forming groups Z1450, P1600 and I1530. Extra groups, Z1530 and Z1600, were originated from ceramill Zolid zirconia specimens subjected to modified sintering cycles. The thirteen specimens that were manufactured for each group were submitted to x-ray diffraction analysis, density, average grain size determination and 4-point-bending tests. X-ray diffraction analysis revealed the presence of tetragonal metastable phase in all groups before and after sintering. Relative density found for Prettau and IPS e.max ZirCAD were greater than 99%. The average grain size remained below 1m for all groups. P1600 showed the largest grain sizes (0,814m) while Z1450 (0,463m) demonstrated the smallest ones. Groups originated from ceramill Zolid also presented the lowest Weibull modulus (m=4,58 for Z1530) and flexural strength results (621,01±138,08MPa for Z1450), regardless of non significant improvements that were achieved when using a low heating rate protocol. Prettau zirconia showed better mechanical behaviour and a more homogeneous distribution of results (864,18±118,21MPa), although lower than those of IPS e.max ZirCAD zirconia (1057,41±150,54MPa). Findings from this study show that the two commercial monolithic zirconia under analysis developed distinct mechanical properties and microstructural features from data established for conventional zirconia.
180

Desenvolvimento de metodologia computacional para avaliação do comportamento do tecido ósseo ao redor de diferentes superfícies de implantes em humanos /

Gouveia, Wellington da Rocha. January 2018 (has links)
Orientador: Antônio Carlos Guastaldi / Banca: André de Souza Tarallo / Banca: Luiz Ricardo Menani / Banca: Vanderlei Salvador Bagnato / Banca: Jonas de Carvalho / Resumo: A reabilitação oral utilizando-se implantes dentários está dentre os procedimentos necessários para a manutenção da qualidade de vida do cidadão. No Brasil, são instalados aproximadamente 1 milhão de implantes por ano. Atualmente o procedimento para a instalação de implantes e, subsequentemente, a reabilitação com próteses sobre implantes tem seus custos determinado com os materiais utilizados e pelo tempo que o profissional dispende neste tipo de procedimento. As metodologias modernas, não acompanham a demanda crescente por este tipo de procedimento. É importante salientar que devido ao grande avanço nos equipamentos utilizados para obtenção de radiografias digitais odontológicas, surge a necessidade do desenvolvimento de novas metodologias computacionais para o auxílio no diagnóstico. Essa tese apresenta o início do desenvolvimento de novas metodologias computacionais para processamento e análise de radiografias digitais odontológicas, metodologias essas de suma importância na área odontológica, pois devido ao envelhecimento da população e cada vez mais a necessidade de reabilitação oral com implantes dentários, demonstra que é de suma importância o desenvolvimento de novas metodologias para auxiliar os profissionais de odontologia em seus diagnósticos. / Abstract: Oral rehabilitation using dental implants is among the procedures necessary to maintain the quality of life of the citizen. In Brazil, approximately 1 million implants are installed per year. Currently, the procedure for the implant installation and, subsequently, the rehabilitation with implants has its costs determined with the materials used and the time that the professional spends on this type of procedure. Modern methodologies do not accompany the increasing demand for this type of procedure. It is important to note that due to the great advance in the equipment used to obtain dental digital radiographs, the need arises for the development of new computational methodologies to aid in diagnosis. This thesis presents the beginning of the development of new computational methodologies for the processing and analysis of dental digital radiographs, which are extremely important methodologies in the dental area, since due to the aging of the population and increasingly the need for oral rehabilitation with dental implants, the development of new methodologies to assist dentistry professionals in their diagnosis is of paramount importance. / Doutor

Page generated in 0.1262 seconds