• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 80
  • 49
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 389
  • 389
  • 122
  • 64
  • 64
  • 62
  • 59
  • 57
  • 50
  • 45
  • 40
  • 33
  • 31
  • 30
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Recobrimentos à base de mulita em refratário de carbeto de silício obtidos a partir de PMSQ [POLI (METILSILSESQUIOXANO)] e alumínio / Mullite-based coating on silicon carbide refractory obtained from PMSQ [POLY(METHYLSILSESQUIOXANE)] and aluminium

MACHADO, GLAUSON A.F. 08 November 2017 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2017-11-08T16:39:39Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-08T16:39:39Z (GMT). No. of bitstreams: 0 / O carbeto de silício (SiC) é um material que apresenta baixa expansão térmica, altas resistências mecânica e ao choque térmico e alta condutividade térmica. Em razão disto é empregado na confecção de mobília de fornos de sinterização. O SiC no entanto sofre degradação a altas temperaturas quando submetido a atmosferas agressivas. A utilização de recobrimentos protetores evita a exposição direta da superfície do material à atmosfera dos fornos; a mulita pode ser um recobrimento protetor apropriado em razão de sua alta estabilidade em temperaturas elevadas e seu coeficiente de expansão térmica compatível com o do SiC (4x10-6/°C e 5,3x10-6/°C, respectivamente). No presente trabalho foi estudada a obtenção de recobrimento de mulita, para refratário de SiC, a partir da utilização de polímero precursor cerâmico e alumínio particulado. Foram preparadas composições com 10, 20, 30 e 50% (vol.) de alumínio adicionado ao polímero, sendo utilizados pós de alumínio de diferentes distribuições de tamanhos de partículas. As composições foram submetidas a diversos ciclos térmicos para determinação da condição mais adequada à obtenção de alto teor de mulita. A composição que apresentou melhor resultado foi a contendo 20% do pó de Al de menor tamanho de partículas. A partir desta, foi preparada e aplicada suspensão para ser aplicada sobre o refratário de SiC. A suspensão aplicada, após seca, reticulada e tratada termicamente a 1580°C, originou um recobrimento de mulita. Foram realizados ciclos de choque térmico em amostras com e sem recobrimento para comparação, num total de 26 ciclos. As condições foram 600°C/30 min. seguida de resfriamento ao ar até a temperatura ambiente. Após cada choque térmico, as amostras foram caracterizadas por microscopia óptica e eletrônica e determinado o módulo de elasticidade. Os recobrimentos apresentaram boa adesão e não foram detectados danos significativos após os choques térmicos. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
352

Investigação da resistência à corrosão por pites do aço inoxidável duplex tipo 2404 (UNS S82441) submetido à soldagem por atrito com pino não-consumível (FSW) / Investigation of pitting corrosion resistance of duplex stainless steel LDX 2404 (UNS S82441) subjected to Friction Stir Welding (FSW)

LEITE, ANTONIO M. dos S. 17 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-17T16:32:32Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-17T16:32:32Z (GMT). No. of bitstreams: 0 / Os aços inoxidáveis duplex são largamente utilizados na fabricação de equipamentos para a indústria de óleo e gás, utilizados tanto no ambiente onshore quanto offshore. Sua grande limitação é que, com o aumento de temperatura, ocorre precipitação de fases indesejáveis, que reduzem drasticamente a resistência à corrosão e as propriedades mecânicas desses materiais. Considerando o efeito deletério da soldagem a fusão nos aços inoxidáveis duplex, a soldagem por atrito com pino não-consumível (FSW) é amplamente considerada como alternativa aos processos convencionais. Como no FSW a união dos materiais ocorre no estado sólido, muitos dos problemas de soldabilidade associados às técnicas tradicionais de soldagem por fusão são evitados. Neste trabalho, amostras retiradas da zona misturada (ZM), das zonas afetadas pelo calor (ZTA e ZTMA) e do metal de base (MB) de chapas de aço inoxidável lean duplex LDX 2404&reg (UNS S82441) soldadas por atrito com pino não-consumível foram caracterizadas microestruturalmente e tiveram sua resistência à corrosão avaliada por meio de ensaios eletroquímicos. Os resultados obtidos nos ensaios eletroquímicos indicaram que as zonas afetadas pelo calor e a ZM se mantiveram tão resistentes à corrosão localizada quanto o MB. Permitiram concluir também que a excelente resistência à corrosão da liga está associada ao teor elevado de N. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
353

Estudo da resistência à corrosão das ligas de alumínio 2024-T3 e 7475-T651 soldadas por fricção e mistura (FSW) / Study of the corrosion resistance of aluminium alloys 2024-T3 and 7475-T651 welded by friction stir welding (FSW)

BUGARIN, ALINE de F.S. 21 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-21T11:56:39Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-21T11:56:39Z (GMT). No. of bitstreams: 0 / O processo de soldagem por fricção e mistura (FSW) tem despertado grande interesse nos últimos anos e tornou-se uma alternativa para unir materiais de baixa soldabilidade, como as ligas de alumínio das séries 2XXX e 7XXX, as quais são empregadas na estrutura das aeronaves, por possuírem elevada relação resistência/peso. O processo FSW, todavia, causa mudanças microestruturais nos materiais soldados, particularmente na zona misturada (ZM) e nas zonas termicamente (ZTA) ou termomecanicamente (ZTMA) afetadas. Estas mudanças geralmente interferem no desempenho frente à corrosão das ligas soldadas. No presente estudo, a resistência à corrosão das ligas de alumínio 2024-T3 e 7475-T761, unidas pelo processo FSW foi investigada em solução 10 mM de NaCl. Ensaios de visualização em gel ágar-ágar e de imersão associados a técnicas microscópicas foram realizados para investigar o efeito do acoplamento galvânico na corrosão das diferentes regiões da junta soldada. Os resultados do ensaio de visualização em gel mostraram que, quando acopladas, a liga 2024 atua como cátodo e a 7475 como ânodo. Os ensaios de imersão revelaram acoplamento galvânico entre as ligas na zona misturada (ZM). A região mais afetada pela corrosão foi a ZTMA da liga 7475, com corrosão intergranular desde as primeiras horas de imersão. A influência do processo de soldagem na resistência à corrosão das duas ligas de alumínio foi investigada por ensaios eletroquímicos. Os ensaios eletroquímicos adotados foram medidas de potencial de circuito aberto (PCA) em função do tempo de exposição ao meio corrosivo, espectroscopia de impedância eletroquímica (EIE) e curvas de polarização potenciodinâmica. Os ensaios de polarização mostraram elevada atividade eletroquímica na zona de mistura indicada pelos altos valores de densidade de corrente em comparação com as demais zonas testadas. Os resultados de EIE globais mostraram que nas primeiras horas de exposição ao eletrólito o processo de corrosão foi predominantemente controlado pela liga 7475; todavia, com o tempo de exposição ao eletrólito, a corrosão passou a ser controlada pela liga 2024. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
354

Biocompatibilidade in vivo de material resiliente temporário para base de prótese modificado por antimicrobianos para tratamento da estomatite protética / Biocompatibility in vivo of temporary soft denture liner for denture base modified by antimicrobials agents for denture stomatitis treatment

Juliana Hotta 10 November 2016 (has links)
Reembasadores resilientes temporários contendo fármacos antifúngicos foram sugeridos como um tratamento adjunto para estomatite protética. No entanto, antes de utilizar clinicamente estes reembasadores modificados em humanos, é importante avaliar a sua biocompatibilidade em modelos animais. Este estudo avaliou a biocompatibilidade in vivo de um reembasador resiliente temporário para base de prótese (Trusoft) modificado por agentes antimicrobianos em suas mínimas concentrações inibitórias (MCIs) para biofilme de Candida albicans. Dispositivos acrílicos intra-orais (DIOs) foram confeccionados individualmente para 60 ratos Wistar. Os ratos foram divididos em 6 grupos (n=5): 3 grupos controle (Negativo: sem DIO; Geral: DIO sem reembasamento; Positivo: DIO reembasado com Trusoft sem fármacos) e 3 grupos experimentais (DIOs reembasados com Trusoft modificados por fármacos em suas respectivas MCIs: 0,032 g de nistatina, 0,064 g de diacetato de clorexidina e 0,128 g de cetoconazol). Os ratos com ou sem os DIOs foram eutanasiados após 7 e 14 dias de avaliação. A análise histopatológica qualitativa foi realizada comparando-se fotomicrografias de secções histológicas, que foram obtidas utilizando um microscópio óptico que abrangeu transversalmente a região intermolares. As alterações morfológicas no epitélio e queratina foram analisadas quantitativamente através da realização de planimetria computadorizada. Os dados quantitativos foram analisados utilizando ANOVA 2-fatores e teste de Tukey (=0,05). A análise quantitativa mostrou que apenas o grupo com DIO contendo cetoconazol diminuiu significativamente a espessura e a área do estrato córneo em comparação com os outros grupos (p<0,05), que não apresentaram diferenças significativas entre si (p>0,05). Estes resultados estiveram de acordo com os obtidos para análise qualitativa. A incorporação de MCIs de nistatina e diacetato de clorexidina no Trusoft não induziram alterações histopatológicas na mucosa palatina de ratos, sugerindo a biocompatibilidade in vivo deste protocolo para o tratamento de estomatite protética. / Temporary resilient denture liners containing antifungal drugs have been suggested as an adjunct treatment for denture stomatitis. However, before clinically using these modified liners in humans, it is important to assess their biocompatibility in animal models. This study evaluated the in vivo biocompatibility of a temporary soft denture liner (Trusoft) modified by antimicrobial agents at their minimum inhibitory concentrations (MICs) for biofilm formation by Candida albicans. Methods: Acrylic intraoral devices (IODs) were individually made for 60 Wistar rats. The rats were divided into the following 6 groups (n=5): 3 control groups (Negative: without IOD; General: IOD without relining; Positive: IOD relined with Trusoft without drugs) and 3 experimental groups (IOD relined with Trusoft modified by drugs at MICs: 0.032 g for nystatin, 0.064 g for chlorhexidine diacetate, and 0.128 g for ketoconazole). The rats with or without the IODs were sacrificed after 7 or 14 days of evaluation. Histopathological qualitative analysis was performed by comparing photomicrographs of histological sections, which were obtained using an optical microscope that transversely covered the inter-molar region. Morphological changes in the epithelium and keratin were quantitatively analyzed by performing computerized planimetry. Quantitative data were analyzed using 2-way ANOVA and Tukey\'s test (=0.05). Quantitative analysis showed that only the group with IOD containing ketoconazole significantly decreased the thickness and area of the stratum corneum compared with the other groups (p<0.05), which showed no significant differences between each other (p>0.05). These results were in accordance with those obtained for qualitative analysis. Incorporation of MICs of nystatin and chlorhexidine diacetate in Trusoft did not induce histopathological changes in the palatal mucosa of rats, suggesting the in vivo biocompatibility of this protocol for treating denture stomatitis.
355

Avaliação da força de repulsão entre magnetos de neodímeo ferro boro usados em tratamentos intra e extra bucais / Evaluation of repulsion force between Neodymium Iron Boron magnets used for intra and extra oral treatments

Renato Sartori Lardin Sanchez 15 February 2012 (has links)
Os magnetos de Neodímio Ferro Boro (Nd2Fe14B) apresentam excelentes propriedades magnéticas e compatibilidade biológica, embora sejam frágeis e possuam baixa resistência à corrosão. As forças de atração magnética de magnetos de terras raras têm sido empregadas em sistemas de retenção, principalmente associadas aos implantes osseointegráveis, em próteses bucais e próteses faciais, bem como em aparelhos ortodônticos. Este estudo avalia o comportamento das forças de repulsão magnética, em função do volume e comprimento do eixo magnético, quando submetidos a afastamentos, de modo que esta propriedade física seja empregada em odontologia. Vinte e quatro corpos de prova, com um ou dois pares de magnetos de Nd2Fe14B, com diferentes formas e volumes variados, foram submetidos a ensaio mecânico para mensuração das forças de repulsão magnética, em condições de afastamentos que variaram entre 0,0 e 20,0 mm. Os dados observados mostram que, considerando-se uma mesma área superficial de polo, a força de repulsão magnética varia em função do comprimento do eixo magnético. Os dados relativos ao afastamento foram submetidos a análise de variância (p0,05), tendo-se observado que o aumento da distância entre os magnetos diminui significantemente a força de repulsão magnética na maioria dos corpos de prova. No afastamento 0,0 mm as forças magnéticas de repulsão dos subgrupos mantêm uma sequência crescente a partir do subgrupo de menor volume de magnetos ao subgrupo de maior volume de magnetos, os quais permanecem nessa sequência nos afastamentos iniciais. A força de repulsão magnética gerada por magnetos pequenos varia menos em função do aumento do afastamento. Conclui-se que a variação da força de repulsão magnética, dada a mesma área superficial de polo, apresenta uma relação direta com o volume e com o eixo magnético onde, quanto maior o volume ou o comprimento do eixo magnético, maior a força de repulsão magnética. A relação direta entre volume e força de repulsão magnética não se altera frente aos afastamentos inicais, tendendo a se tornar imensurável com o aumento da distância. A força de repulsão magnética mantém uma relação inversa com a distância entre os pares de magnetos. Este ensaio mecânico indica que a força de repulsão magnética apresenta, assim como a força de atração magnética, uma curva hiperbólica de redução frente ao aumento do afastamento. / Neodymium Iron Boron (Nd2Fe14B) magnets exhibit excellent magnetic properties and demonstrate biological compatibility, despite of their fragility and low resistance to corrosion. The magnetic attraction forces of rare earth magnets have been used in retention systems mainly associated with osseointegrated implants, in oral and facial prostheses, as well as orthodontic appliances. This study evaluates the repulsion forces of magnets, varying volume and length of magnetic axis when subjected to vertical distance, in order to assess the usefulness of such physical property in clinical situations. Twenty-four specimens, with one or two pairs of Nd2Fe14B magnets, presenting different shapes and various volumes, were subjected to mechanical testing so as to measure magnetic repulsion forces, under conditions of vertical pole face separation ranging from 0.0 to 20.0 mm. Repulsive magnetic force varies depending on the length of the magnetic axis, when considering the same surface area of a pole. Analysis of Variance - (p0.05) indicated that by increasing the distance between the pairs of magnets, magnetic repulsion force significantly reduces in most of the specimens. Starting at a 0.0 mm distance, the magnetic repulsion forces keep an enhancing sequence from lower to higher magnetic volume, holding these characteristics during initials distances. Repulsion magnetic forces generated by small magnets varies less as the distance increases. The results indicate the repulsion magnetic force variation, fixing the same pole surface area, presenting a direct relationship between volume and magnetic axis, since the increase of the volume or of the magnetic axis length leads to a higher magnetic repulsive force. The relationship between volume and magnetic repulsion force does not vary at initial distance. Nevertheless, when such distance increases, the force between the magnets significantly decreases. The magnetic repulsion force holds an inverse relationship with respect to the distance between magnets pairs. This mechanical test indicates that the magnetic repulsion force, as well the magnetic attraction force, present a hyperbolic curve of force reduction due to the increasing vertical distance.
356

Determinação das dimensões espaciais de corpos sólidos por técnicas ópticas de moiré / Moiré aided three dimentional determinations of solid bodies

Silva, Marcos Valério Gebra da, 1971- 18 August 2018 (has links)
Orientadores: Inacio Maria Dal Fabbro, Celina de almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-18T14:46:35Z (GMT). No. of bitstreams: 1 Silva_MarcosValerioGebrada_M.pdf: 5359194 bytes, checksum: e831ae3ea9b56a4d77ebb1a53f2352da (MD5) Previous issue date: 2011 / Resumo: A medição de sólidos tridimensionais tem recebido uma grande atenção da comunidade científica, devido à sua ampla gama de aplicações. Como por exemplo, no controle de qualidade industrial, na medição do corpo humano para aplicações de ergonomia, e muitas outras áreas. Porém existem diversos métodos e técnicas para se obter tais medições, este trabalho demonstra a técnica de moiré que é uma técnica sem contato e não destrutiva, com um rápido processo de digitalização cujos fenômenos de Franjas de Moiré são o resultado da subtração da projeção de grades sobre um certo objeto com relação as grades projetadas em um plano referencial. Possui medição precisa comparável com a de outros sistemas. Demonstra também a exatidão das técnicas de moiré, sendo dado maior enfoque na técnica de moiré de projeção com deslocamento de fase, e pela utilização de dois tipos de grades a de Ronchi e senoidal, onde são observados os possíveis erros das diversas técnicas de moiré e por outros métodos metrológicos. Neste trabalho foi comprovado o melhor desempenho dos tipos e variação da frequência de grades incluindo vários exemplos práticos da sua aplicação em sólidos regulares e irregulares (frutos), comparação com outras técnicas em vários problemas em engenharia agrícola e determinação volumétrica de sólidos regulares e irregulares. Emprego de "softwares" gratuitos o qual também foi uma preocupação para disseminação da técnica, tais como ImageJ, RisingSun Moiré, SCILAB/SIP e rotinas / Abstract: Measurement of three-dimensional solids has received great attention from the scientific community due to its wide range of applications. As examples in can be mentioned industrial quality control, human body measurement applied to ergonomics and many other areas. The pertinent literature discloses several methods and techniques to carry three dimensional measurements. Moiré technique is a group of non-contact and non-destructive methods based on the more phenomena which fringes are the result of the subtraction of the grid projected onto the surface under study and the grid projected onto a reference plane. Moiré methods are yield accurate measurements if compared to other measuring systems. This work was foccused on the projection moiré technique with phase shift, and the use of two types of grids named Ronchi and sinusoidal one. Metrological errors of various techniques as compared with the moiré method have been determined as well. This work demonstrated the best performance of grid frequency variation through several practical applied to regular and irregular solids (fruits). Body dimensions were compared with convention techniques as water immersion and calypper. The application of free software such as ImageJ, RisingSun Moire, Scilab / SIP and routines was considered very useful to reach the final results / Mestrado / Maquinas Agricolas / Mestre em Engenharia Agrícola
357

Fotossensibilizadores nanoestruturados por sistema camada por camada

Faria, Ana Claudia Rangel 28 July 2011 (has links)
A busca por materiais que possam ser modificados em nível molecular tem sido o alvo de numerosas pesquisas no mundo. Desta maneira, as técnicas de fabricação de filmes finos se destacam devido à possibilidade de se reduzir custos e melhorar a eficiência de sistemas como, por exemplo, os fotossensíveis. Neste contexto, o objetivo deste trabalho foi a obtenção e caracterização de filmes finos através da técnica de automontagem (técnica "camada por camada" ou Layer-by-Layer). Os filmes foram depositados sobre diversos substratos (lamínula de vidro, silício e poliestireno). Nesse trabalho foram depositados dois conjuntos diferentes de multicamadas combinados com duas proporções diferentes de cada sistemas de soluções. O sistema catiônico foi composto pela solução do polieletrólito orgânico PDDA e a solução coloidal do semicondutor inorgânico seleneto de cádmio (CdSe). O sistema aniônico foi composto por solução do poli(ácido acrílico) (PAA) e solução de óxido de titânio (TiO2), respectivamente. Os materiais utilizados para a obtenção dos filmes e os filmes finos nanoestruturados produzidos foram caracterizados por meio de diversas técnicas. As regiões de absorção das soluções coloidais inorgânicas foram determinadas por espectroscopia de absorção molecular no ultravioleta-visível (UV-Vis) e apresentaram absorção em 320 nm (TiO2) e 440 nm (CdSe). O diâmetro das nanopartículas inorgânicas de TiO2 e de CdSe foram mensurados por difração de raios X (DRX) e microscopia eletrônica de transmissão (MET), revelando valores em escala nanométrica. Observou-se no difratograma do pó nanoparticulado de TiO2 que a fase predominante no mesmo é a anatase, e que houve uma sobreposição dos picos de maior intensidade do TiO2 e do CdSe, ambos em 2q = 25,3°. O espectro de refletância difusa (RDUV-Visível) dos filmes automontados apresentou valores compatíveis com as das soluções formadoras dos filmes, indicando que os mesmos apresentam aplicação em dispositivos fotossensíveis. Através dos comprimentos de onda obtidos a partir das técnicas de UV-Vis e RDUV-Vis foi possível estimar os valores de energia de bandas proibidas (Ebg) para os semincondutores TiO2 e CdSe. As espessuras dos filmes foram determinadas pelas técnicas de perfilometria e por microscopia eletrônica de varredura (MEV), e encontram-se na ordem de grandeza micrométrica. Pelas micrografias de MEV foi possível avaliar a superfície dos filmes que revelaram alta rugosidade, formação de ilhas de TiO2 e aglomeração de grãos esféricos (Se). Nas imagens de MET, observou-se a distribuição das nanopartículas dos semicondutores na seção transversal dos filmes, corroborando as aglomerações observadas por MEV. / The search for materials that can be modified at molecular level has been the subject of several studies worldwide. Thus, the production techniques of thin films stand out due to the possibility of reducing costs and improving the efficiency of systems, such as photosensitive systems. In this context, the aim of this study was to obtain and characterize thin films using the self-assembly technique (layer by layer technique or LbL). The thin films were deposited on different substrates (glass coverslips, silicon and polystyrene). In this work two different multilayer sets combined with two different proportions of each solution system were deposited. The cationic system was composed by the poly(diallyldimethilammonium) (PDDA) organic polyelectrolyte solution and the cadmium selenide (CdSe) inorganic semiconductor colloidal solution. The anionic system was composed by the poly(acid acrylic) (PAA) solution and the titanium dioxide (TiO2) solution, respectively. The materials used for the achievement of films and nanostructured thin films produced were characterized through various techniques. The absorption regions of inorganic colloidal solutions were determined by UV-Vis spectroscopy and presented absorption at 320 nm (TiO2) and 440 nm (CdSe). The resulting inorganic nanoparticles diameter of TiO2 and CdSe were measured by X ray diffraction (XRD) and transmission electron microscopy (TEM), resulting in values at nanometric scale. It was observed in the nanoparticle TiO2 powder diffractogram that anatase is the most abundant phase, and that there was an overlap of the highest intensity diffraction peaks of TiO2 and CdSe, both at 2q = 25.3 °. The diffuse reflectance spectrum (RDUV-Vis) of self-assembled films presented values compatible with those of the film forming solutions. Using the wavelengths obtained from the UVVis and Vis-RDUV techniques it were possible to evaluate values for the energy band gap (Ebg) seminconductors TiO2 and CdSe. The thicknesses of the films were determined by profilometry and scanning electron microscopy (SEM) techniques, and they are in the micrometric order of magnitude. Using the SEM micrographs, it was possible to evaluate the surface of the films that show a high roughness, the formation of TiO2 clumps and the agglomeration spherical selenium clusters. In TEM images, the distribution of the semiconductor nanoparticles in cross-section of films can be observed, confirming agglomerations observed by SEM.
358

Evaluation of physicochemical properties of a new epoxy resinbased root canal sealer / Avaliação das propriedades físico-químicas de um novo cimento obturador de canais radiculares à base de resina epóxica

Vertuan, Gislene Cristina 10 July 2018 (has links)
Introduction: The aim of this study was to evaluate some of the physico-chemical properties of a new root canal sealer. Methodology: The sealers tested were Sealer Plus (MKLife, Porto Alegre, Rio Grande do Sul, Brazil), compared as AH Plus (Dentsply, DeTrey GmbH, Konstanz, Alemanha). For the radiopacity, flow, solubility and fabrication of test specimens relative to setting times the ANSI/ADA No. 57 (2000) and ISO 6876 (2012) specifications were followed. To measure the initial and final setting times the ASTM C266/2008 standard was used. pH was evaluated in the time intervals of 3, 24, 72 and 168 hours). Statistical tests were applied to the results obtained at a level of significance of 5%. Results: The results demonstrated that the Sealer Plus sealer showed a lower radiopacity value than AH Plus sealer (p<0.05), however, this was higher than the minimum value recommended by the specifications; that is 3 mm Al. Relative to flow, the value for Sealer Plus was 19.19 mm and for AH Plus, 19.81 mm (p>0.05). Sealer plus presented initial and final setting times of 138 min. and 210 min., respectively, while the values for AH Plus were 437 min. and 849 min., respectively, (p<0.05). Relative to solubility, Sealer Plus presented 0.21% and AH Plus, 0.27% (p>0.05). None of the sealers showed a significant increase in pH (p>0.05). Conclusion: Sealer Plus sealer presented physico-chemical properties in accordance with ANSI/ADA (2000) No.57 and ISO 6876 (2012) specifications. / Introdução: Este estudo objetivou avaliar algumas propriedades físico-químicas de um novo cimento obturador de canais radiculares. Metodologia: Para os testes de radiopacidade, escoamento, solubilidade e confecção dos corpos de prova para os tempos de presa foram seguidas as especificações nº57 da ANSI/ADA (2000) e ISO 6876 (2012). Para a medição dos tempos de presa, inicial e final, foi empregada a norma ASTM C266/2008. O pH foi avaliado nos períodos de 3, 24, 72 e 168 horas. Sobre os resultados foram aplicados testes estatísticos com nível de significância de 5%. Resultados: Os resultados demonstraram que o cimento Sealer Plus apresentou menor radiopacidade do que o cimento AH Plus (p<0.05), porém, superior ao mínimo recomendado pelas especificações, ou seja, de 3 mm de Al. Com relação ao escoamento, o do Sealer Plus foi 19,19 mm e do AH Plus 19,81 mm (p>0.05). O Sealer Plus apresentou tempos de presa inicial e final de 138 min. e 210 min., respectivamente, enquanto o AH Plus, 437 min. e 849 min., respectivamente, (p<0.05). Em relação à solubilidade, o Sealer Plus apresentou 0,21% e o AH Plus 0,27% (p>0.05). Nenhum dos cimentos apresentou aumento significativo do pH (p>0.05). Conclusão: O cimento Sealer Plus apresentou propriedades físico-químicas de acordo com as especificações nº 57 da ANSI/ADA (2000) e ISO 6876 (2012).
359

Analytical Model for Lateral Deflection in Cold-formed Steel Framed Shear Walls with Steel Sheathing

Yousof, Mohamad 12 1900 (has links)
An analytical model for lateral deflection in cold-formed steel shear walls sheathed with steel is developed in this research. The model is based on the four factors: fastener displacement, steel sheet deformation, and hold-down deformation, which are from the effective strip concept and a complexity factor, which accounts for the additional influential factors not considered in the previous three terms. The model uses design equations based on the actual material and mechanical properties of the shear wall. Furthermore, the model accounts for aggressive and conservative designers by predicting deflection at different shear strength degrees.
360

Vliv teploty vzduchu na FDM 3D tisk / Effect of air temperature on FDM 3D printing

Hrdlička, Martin January 2017 (has links)
The thesis deals with 3D printing by the FDM and ambient temperature on print quality. The thesis describes the principle of printing by the FDM method and the occurrence of errors caused by the influence of ambient temperature. The aim of the thesis is to design a heated chamber for RepRap Prusa i3 printer, its construction and subsequent testing of ambient temperature influence on print quality. To test the occurrence of the described errors, specific tests and materials are selected in the work. The result of this work is the recommended ambient temperature in the heated chamber for improved FDM printing.

Page generated in 0.1197 seconds