• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 80
  • 49
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 389
  • 389
  • 122
  • 64
  • 64
  • 62
  • 59
  • 57
  • 50
  • 45
  • 40
  • 33
  • 31
  • 30
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Mechanické vlastnosti nízkouhlíkových a nízkolegovaných ocelí, stanovené pomocí protlačovacích zkoušek na miniaturních discích při pokojové a snížených teplotách / Determination of mechanical properties of low carbon and low alloy steels via small punch tests at room and low temperatures

Závodský, Peter January 2016 (has links)
The presented diploma thesis deals with an innovative material test, so called Small Punch Test. There are main principles, advantages and limitations of the test stated in the thesis. There are stated also correlation procedures in order to obtain standard mechanical properties. A test fixture design has been done in order to perform test procedures at temperature range from 80 to 25 °C. Twelve experimental curves have been obtained from the test and typical quantities have been evaluated. The different accuracy of correlations with standard mechanical properties has been obtained using different correlation equations.
382

Испитивање биокомпатибилности објеката од полимера произведених адитивном технологијом за примену у области стоматологије / Ispitivanje biokompatibilnosti objekata od polimera proizvedenih aditivnom tehnologijom za primenu u oblasti stomatologije / Testing the biocompatibility of objects from polymers produced by additive manufacturing for use in dentistry

Vuletić Rakić Jelena 14 October 2016 (has links)
<p>Uobičajeni pristup i testiranju biolo&scaron;kog pona&scaron;anja materijala je da se počne sa jednostavnim in vitro testovima baziranim na ćelijskim kulturama. In vitro testovi citotoksičnosti su danas jedan od osnovnih načina za procenu biolo&scaron;kog odgovora na materijal jer su brži, lak&scaron;i za ponavljanje, ocenjivanje i jeftiniji u odnosu na eksperimente koji se izvode na životinjama i ljudima. Koriste se kao neka vrsta skrining testova za procenu biolo&scaron;ke sigurnosti materijala. Za razliku od ćelijskih kultura, istraživanja koja uključuju eksperimentalne životinje pružaju bolji uvid u biokompatibilnost materijala, zbog mogućnosti praćenja kompleksnog imunolo&scaron;kog odgovora živog organizma. Smatraju se neophodnim za ocenu bilo&scaron;kih odgovora na novi materijal, pre nego &scaron;to se on upotrebi na ljudima. Mnogi aspekti biolo&scaron;kog odgovora ne mogu biti reprodukovani in vitro testovima uključujući krvne interakcije, zarastanje rana, reakcije preosetljivosti, karcinogenezu, hroničnu inflamaciju. Eksperimenti na životinjama pružaju informacije o ovim tipovima efekata bez izlaganja ljudi riziku. Cilj ovog istraživanja bio je da se oceni biokompatibilnost objekata od polimera na bazi epoksi smole Accura&reg; ClearVue&trade; (hemijski sastav: 4,4&rsquo;- izopropilidendicikloheksanol, produkti oligomerne reakcije sa 1-hlor-2,3- epoksipropanom(40-65%), sme&scaron;а triaril-sulfonijum soli (50% propilen-karbonata i 50% triaril-sulfonijum heksafluoroantimonatnih soli) (1-10%) i 3-etil-3hidroksimetil-oksetan(10-20%). U oceni citotoksičnosti materijala Accura&reg; ClearVue&trade; kori&scaron;ćeni su agar diguzioni i MTT test. Oba testa rađena sun a ćelijskim kulturama L929 (mi&scaron;iji fibroblasti) i MRC-5 (humani fibroblasti). Ocena biokompatibilnosti testiranog materijala vr&scaron;ena je na osnovu urađenog testa iritacije oralne mukoze na modelu bukalne kesice hrčka, &scaron;to je definisano standardom ISO 10993-10:2010. Biokompatibilnost materijala ispitana je i implantacijom uzoraka u potkožno tkivo dorzuma pacova soja Wistar.</p> / <p>Uobičajeni pristup i testiranju biolo&scaron;kog pona&scaron;anja materijala je da se počne sa jednostavnim in vitro testovima baziranim na ćelijskim kulturama. In vitro testovi citotoksičnosti su danas jedan od osnovnih načina za procenu biolo&scaron;kog odgovora na materijal jer su brži, lak&scaron;i za ponavljanje, ocenjivanje i jeftiniji u odnosu na eksperimente koji se izvode na životinjama i ljudima. Koriste se kao neka vrsta skrining testova za procenu biolo&scaron;ke sigurnosti materijala. Za razliku od ćelijskih kultura, istraživanja koja uključuju eksperimentalne životinje pružaju bolji uvid u biokompatibilnost materijala, zbog mogućnosti praćenja kompleksnog imunolo&scaron;kog odgovora živog organizma. Smatraju se neophodnim za ocenu bilo&scaron;kih odgovora na novi materijal, pre nego &scaron;to se on upotrebi na ljudima. Mnogi aspekti biolo&scaron;kog odgovora ne mogu biti reprodukovani in vitro testovima uključujući krvne interakcije, zarastanje rana, reakcije preosetljivosti, karcinogenezu, hroničnu inflamaciju. Eksperimenti na životinjama pružaju informacije o ovim tipovima efekata bez izlaganja ljudi riziku. Cilj ovog istraživanja bio je da se oceni biokompatibilnost objekata od polimera na bazi epoksi smole Accura&reg; ClearVue&trade; (hemijski sastav: 4,4&rsquo;- izopropilidendicikloheksanol, produkti oligomerne reakcije sa 1-hlor-2,3- epoksipropanom(40-65%), sme&scaron;a triaril-sulfonijum soli (50% propilen-karbonata i 50% triaril-sulfonijum heksafluoroantimonatnih soli) (1-10%) i 3-etil-3hidroksimetil-oksetan(10-20%). U oceni citotoksičnosti materijala Accura&reg; ClearVue&trade; kori&scaron;ćeni su agar diguzioni i MTT test. Oba testa rađena sun a ćelijskim kulturama L929 (mi&scaron;iji fibroblasti) i MRC-5 (humani fibroblasti). Ocena biokompatibilnosti testiranog materijala vr&scaron;ena je na osnovu urađenog testa iritacije oralne mukoze na modelu bukalne kesice hrčka, &scaron;to je definisano standardom ISO 10993-10:2010. Biokompatibilnost materijala ispitana je i implantacijom uzoraka u potkožno tkivo dorzuma pacova soja Wistar.</p> / <p>The usual approach in testing biological behavior of materials is to start with simple in vitro tests based on cell cultures. In vitro cytotoxicity tests are one of the basic methods of assessing the biological response to material because they are faster, cheaper, easier for repeating and evaluating compared to experiments carried out on animals and humans. They are used as a kind of screening test for evaluating the biosafety of materials. Unlike cell culture, studies involving experimental animals provide better insight into the biocompatibility of materials due to the possibility of monitoring the complex immune response of a living organism. They are considered necessary for assessing the biological response to new material before it is used on humans. Many aspects of a biological response cannot be reproduced with in vitro tests, including blood interaction, wound healing, hypersensitivity reactions, carcinogenesis, chronic inflammation. Animal experiments provide information about these types of effects without exposing humans to risk.&nbsp; The aim of this study was to evaluate the biocompatibility of polymer objects on the basis of epoxy resins Accura&reg; ClearVue &trade; (chemical composition: 4.4&#39; Isopropylidenedicyclohexanol, oligomeric reaction products with 1-chloro-2.3-epoxypropane (40-65%), a mixture of triaryl sulfonium salt (50% propylene carbonate and 50% of a triarylsulfonium hexafluoroantimonate salt) (1- 10%) and 3-ethyl-3-hydroxymethyl-oxetane (10-20%). In the assessment of the cytotoxicity of materials Accura&reg; ClearVue &trade; agar diffusion and MTT tests were used. Both tests were conducted on cell cultures L929 (mouse fibroblasts) and MRC-5 (human fibroblasts). An assessment of the biocompatibility of the tested material was done on the basis of an oral mucosa irritation test on a hamster cheek pouch as defined by ISO 10993-10: 2010. The biocompatibility of the material was also tested with the implantation of a samples into the dorsal subcutaneous tissue of a Wistar rats. The subcutaneous implantation test, as one of the most reliable methods for assessing the biocompatibility of dental materials, is defined by ISO 10993-6: 2010. The study was conducted on 30 rats which were sacrificed in groups</p>
383

Chlorhexidine does not improve but preserves bond strength to eroded dentin.

Francisconi dos Rios, Luciana Fávaro, Calabria, Marcela Pagani, Casas-Apayco, Leslie, Honório, Heitor Marques, Carrilho, Marcela Rocha De Oliveira, Pereira, José Carlos, Wang, Linda 02 1900 (has links)
El texto completo de este trabajo no está disponible en el Repositorio Académico UPC por restricciones de la casa editorial donde ha sido publicado. / PURPOSE: To evaluate the effect of aqueous solutions of chlorhexidine digluconate (CHX) in different concentrations on bond strength to eroded dentin up to 6 months, using normal dentin as a control. METHODS: Exposed flat dentin of extracted third molars was only ground with 600-grit SiC paper/1 minute (normal dentin - N), or subsequently eroded by a regular-cola soft-drink (eroded dentin - E). N and E were acid-etched, washed, dried and rehydrated with 1.5 μL, respectively, of distillated water (control - NC / EC); of 0.004% CHX (N0.004% / E0.004%); or of 2% CHX (N2% / E2%). Adper Single Bond 2 was applied in all specimens and resin composite buildups were constructed with Filtek Z350. Specimens were sectioned in beams, which were tested (μTBS) immediately or after 6 months of aging. RESULTS: Microtensile bond strength to eroded dentin was always significantly lower than that to normal dentin. Application of tested CHX solutions did not exert a significant effect immediately; however, after aging, the 2% CHX prevented abrupt bond strength loss both to eroded and normal dentin. / Revisión por pares
384

Biocompatibilidade de matrizes de colágeno aniônico e sua influência na orientação do crescimento celular

Buchaim, Rogério Leone 17 May 2004 (has links)
Made available in DSpace on 2016-01-26T12:51:52Z (GMT). No. of bitstreams: 1 rogerioleonebuchaim_tese.pdf: 3407631 bytes, checksum: 87786b69303a26860816554562d2cdab (MD5) Previous issue date: 2004-05-17 / The present study was aimed at examining the biocompatibility of anionic collagen matrices, their local bone response following implantation in surgically-created bone defects and also the influence of the collagen fiber orientation in the neoformed bone tissue. Seventy two rats ( Rattus norvegicus albinus ) were used in this experiment. The animals were divided into four experimental groups: Group 1 (control), without implants; Group 2, pericardium medullar implants, 12 hours; Group 3, medullar implants of tendon, 24 hours, with the bigger axes of collagen fibers parallel to the bigger axes of the tibia; and Group 4, medullar implants of tendon, 24 hours, with the bigger axes of collagen fibers perpendicular to the bigger axes of the tibia. After the experimental surgery, the evolution of the repair process was microscopically evaluated in 7, 15 and 30 days post-surgery. The results demonstrated the implanted matrices to be biocompatible and to function as a scaffold inducing the formation of bone, mainly in Group 4. At first, the cellularity follows the arrangement of collagen fibers, obtaining a growing multidirectional arrangement, suggesting that the direction and the orientation are related to the direction and to the magnitude of the stress applied to the bone. / Este estudo apresentou como objetivo, examinar a biocompatibilidade de matrizes de colágeno aniônico, sua resposta óssea local após implantação em defeitos ósseos criados cirurgicamente e a influência da orientação das fibras colágenas no tecido ósseo neoformado. Foram utilizados 72 ratos (Rattus norvegicus albinus) divididos em 4 grupos experimentais de 6 animais cada: Grupo 1 (controle), sem implante; Grupo 2, implante medular pericárdio 12 horas; Grupo 3, implante medularde tendão 24 horas, com o maior eixo de suas fibras colágenas direcionados paralelamente ao maior eixo da tíbia e , Grupo 4, implante medular de tendão 24 horas, com o maior eixo de suas fibras colágenas direcionadas perpendicularmente ao maior eixo da tíbia. A evolução do processo de reparo, após a cirurgia experimental, foi avaliada microscopicamente com 7, 15 e 30 dias pós-operatórios. Os resultados demosntraram que as matrizes implantadas são biocompatíveis e funcionam como uma matriz tridimensional induzindo a formação de osso, maior no grupo 4. a celularidade, inicialmente, acompanha o arranjo das fibras colágenas, adquirindo um arranjo multidirecional crescente, sugerindo que a direção e a orientação estão relacionadas com a direção e a magnitude do stress aplicado sobre o osso.
385

Laboratory Evaluation of Water-Repellent Soils for Water Harvesting

Fink, Dwayne H. 20 April 1974 (has links)
From the Proceedings of the 1974 Meetings of the Arizona Section - American Water Resources Assn. and the Hydrology Section - Arizona Academy of Science - April 19-20, 1974, Flagstaff, Arizona / Reported are laboratory evaluations to screen water-repellent materials and treatments before testing them in the field. Water repellency tests were conducted on paraffin wax, a wax emulsion and silicon, lard, and a liquid dust suppressant. Six water repellency tests showed that the high rates of paraffin wax and all rates of the dust suppressant produced highly water-repellent soil surfaces. The six water repellency tests were: (1) the aqueous-alcohol drop test for determination of the 90 degree surface tension for a porous solid, (2) the water drop penetration time test, (3) the relative height of a large sessile water drop resting on the smoothed, treated soil surface, (4) and (5) the presence and persistence of air bubbles trapped between the soil-water interface, and test (6) was made to note whether the large sessile water drop from test (3) would infiltrate the soil or evaporate. Tests (3), (4), and (5) proved the most useful of the six methods for measuring water repellency. Soil type had no significant influence on degree of water repellency as measured in the laboratory by these six tests.
386

O efeito bake hardening na estampagem a quente e a estrutura veicular / The bake hardening effect on hot stamping and the body structure

CASTRO, MARCOS R. de 21 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-21T11:35:55Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-21T11:35:56Z (GMT). No. of bitstreams: 0 / Os projetos de carrocerias veiculares atuais procuram desenvolver estruturas leves, seja para reduzir o consumo de combustível, no caso dos motores de combustão interna, seja para maior autonomia de bateria, no caso dos veículos elétricos e híbridos. Redução no consumo de combustível significa redução na emissão de poluentes. As estruturas precisam ser leves, mas cada vez mais resistentes e rígidas a fim de proporcionar máximo conforto e segurança aos ocupantes. Estas premissas têm levado ao contínuo desenvolvimento dos materiais. No caso dos aços, um dos processos que tem permitido a melhora significativa das propriedades mecânicas é a estampagem a quente. Nos últimos anos, as peças estampadas a quente têm ocupado lugar de destaque na estrutura das carrocerias veiculares por estarem em sintonia com as demandas mencionadas. Há muitas pesquisas em curso para esta tecnologia, seja nos materiais, nos meios de produção, nos revestimentos e em aplicações. O aço mais utilizado neste processo, 22MnB5, também apresenta o chamado efeito bake hardening; a tensão de escoamento é aumentada após tratamento térmico realizado em temperaturas próximas a 200 °C. Neste trabalho, visando à melhoria nas propriedades mecânicas, amostras foram tratadas termicamente na faixa de temperatura supracitada. Após isso, dados obtidos de ensaios mecânicos foram inseridos em programas de simulação de impacto lateral cujo resultado foi a redução na intrusão na célula de sobrevivência. O efeito bake hardening também propiciou um aumento na absorção da energia de impacto em teste estático feito com barras de proteção lateral. O mecanismo metalúrgico envolvido no fenômeno, devido à difusão de intersticiais foi evidenciado no ensaio de atrito interno. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
387

Nerve guides manufactured from photocurable polymers to aid peripheral nerve repair

Pateman, C.J., Harding, A.J., Glen, A., Taylor, C.S., Christmas, C.R., Robinson, P.P., Rimmer, Stephen, Boissonade, F.M., Claeyssens, F., Haycock, J.W. 2015 February 1914 (has links)
Yes / The peripheral nervous system has a limited innate capacity for self-repair following injury, and surgical intervention is often required. For injuries greater than a few millimeters autografting is standard practice although it is associated with donor site morbidity and is limited in its availability. Because of this, nerve guidance conduits (NGCs) can be viewed as an advantageous alternative, but currently have limited efficacy for short and large injury gaps in comparison to autograft. Current commercially available NGC designs rely on existing regulatory approved materials and traditional production methods, limiting improvement of their design. The aim of this study was to establish a novel method for NGC manufacture using a custom built laser-based microstereolithography (muSL) setup that incorporated a 405 nm laser source to produce 3D constructs with approximately 50 mum resolution from a photocurable poly(ethylene glycol) resin. These were evaluated by SEM, in vitro neuronal, Schwann and dorsal root ganglion culture and in vivo using a thy-1-YFP-H mouse common fibular nerve injury model. NGCs with dimensions of 1 mm internal diameter x 5 mm length with a wall thickness of 250 mum were fabricated and capable of supporting re-innervation across a 3 mm injury gap after 21 days, with results close to that of an autograft control. The study provides a technology platform for the rapid microfabrication of biocompatible materials, a novel method for in vivo evaluation, and a benchmark for future development in more advanced NGC designs, biodegradable and larger device sizes, and longer-term implantation studies.
388

A non-conventional multilevel flying-capacitor converter topology

Gulpinar, Feyzullah January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This research proposes state-of-the-art multilevel converter topologies and their modulation strategies, the implementation of a conventional flying-capacitor converter topology up to four-level, and a new four-level flying-capacitor H-Bridge converter confi guration. The three phase version of this proposed four-level flying-capacitor H-Bridge converter is given as well in this study. The highlighted advantages of the proposed converter are as following: (1) the same blocking voltage for all switches employed in the con figuration, (2) no capacitor midpoint connection is needed, (3) reduced number of passive elements as compared to the conventional solution, (4) reduced total dc source value by comparison with the conventional topology. The proposed four-level capacitor-clamped H-Bridge converter can be utilized as a multilevel inverter application in an electri fied railway system, or in hybrid electric vehicles. In addition to the implementation of the proposed topology in this research, its experimental setup has been designed to validate the simulation results of the given converter topologies.
389

Development of Novel Wearable Sensor System Capable of Measuring and Distinguishing Between Compression and Shear Forces for Biomedical Applications

Dimitrija Dusko Pecoski (8797031) 21 June 2022 (has links)
<p>There are no commercially available wearable shoe in-sole sensors that are capable of measuring and distinguishing between shear and compression forces. Companies have already developed shoe sensors that simply measure pressure and make general inferences on the collected data with elaborate software [2, 3, 4, 5]. Researchers have also attempted making sensors that are capable of measuring shear forces, but they are not well suited for biomedical applications [61, 62, 63, 64]. This work focuses on the development of a novel wearable sensor system that is capable of identifying and measuring shear and compression forces through the use of capacitive sensing. Custom hardware and software tools such as materials test systems and capacitive measurement systems were developed during this work. Numerous sensor prototypes were developed, characterized, and optimized during the scope of this project. Upon analysis of the data, the best capacitive measurement system developed in this work utilized the CAV444 IC chip, whereas the use of the Arduino-derived measurement system required data filtering using median and Butterworth zero phase low pass filters. The highest dielectric constant reported from optimization experiments yielded 9.7034 (+/- 0.0801 STD) through the use of 60.2% by weight calcium copper titanate and ReoFlex-60 silicone. The experiments suggest certain sensors developed in this work feasibly measure and distinguish between shear and compressional forces. Applications for such technology focus on improving quality of life in areas such as managing diabetic ulcer formation, preventing injuries, optimizing performance for athletes and military personnel, and augmenting the scope of motion capture in biomechanical studies.</p>

Page generated in 0.1083 seconds