• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 41
  • 11
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 117
  • 117
  • 101
  • 52
  • 45
  • 44
  • 42
  • 41
  • 37
  • 31
  • 15
  • 14
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Estudo metrológico volumétrico de bombas de infusão peristálticas lineares / Volumetric metrological study of peristaltic linear infusion pump

Dumas Junior, Adair 18 August 2016 (has links)
O presente estudo consiste em analisar se o sistema atual de calibração das bombas de um determinado fabricante, baseado na entrada de parâmetros externos e consequente readequação interna por software é adequado para a correção dos volumes infundidos. A literatura carece de estudos sobre bombas de infusão peristálticas lineares, principalmente estudos metrológicos relacionados aos volumes infundidos. Esta carência relaciona-se entre outros fatores, pelos elevados custos das bombas de infusão, bem como à grande quantidade de horas de ensaios necessárias. Para isso, foram analisados os volumes infundidos em taxas mínima, intermediária e máxima de três bombas de infusão peristálticas lineares retiradas aleatoriamente de um hospital no estado do Paraná, que não passavam por manutenção havia exatos doze meses e estavam em uso contínuo no estabelecimento. Foram realizados ensaios em taxa fixa de 25 ml/h em 5 volumes diferentes ao longo da faixa habitual de uso. Também foram feitos ensaios em volume fixo de 10 ml variando-se a taxa de infusão entre 1 ml/h, 25 ml/h e 100 ml/h. Para análise estatística dos resultados, foi feito um teste de normalidade de Anderson-Darling, como a maioria dos resultados não apresentaram características de normalidade, foi feito uma análise do intervalo de confiança das medianas para análise dos resultados. Também foi necessário fazer uma ANOVA para verificação da influência das bombas e das taxas no volume infundido, seguido por uma análise de curva de erros e uma planilha para o cálculo de incertezas das medições. Foi possível verificar que os volumes infundidos pelas bombas deste fabricante, em sua maioria apresentaram mudanças significativas após o processo de calibração, com diminuição na variância e melhora na exatidão dos volumes programados. / This study examined whether the current system calibration of the pumps from a particular manufacturer, based on the input of external parameters and consequent internal readjustment by software, is suitable for the correction of infused volumes. The literature lacks studies on linear peristaltic pump infusion, especially metrological studies related to the infused volume. This deficiency relates among other factors, the high costs of infusion pumps as well as the large amount of hours required for testing. Therefore, the volumes were analyzed by infusing at minimum, intermediate and maximum rates of three linear peristaltic infusion pumps randomly taken from a hospital in the state of Paraná, which had not have maintenance in the latest 12 months and were in continuous use at the hospital. Assays were performed in flat rate of 25 ml / h in 5 different volumes over the usual range of use. Tests at a fixed volume of 10 ml varying the infusion rate at 1 ml/h, 25 ml/h and 100 ml/h were also made. For statistical analysis, an Anderson-Darling normality test was done, as most of the results did not show normal characteristics, an analysis of the confidence interval of the median for analysis of results was done. It was also necessary to do an ANOVA to check the influence of pumps and rates of infused volume, followed by a curve error analysis and a spreadsheet to calculate the measurements uncertainties. It was possible to verify that the volumes infused by the bombs from this manufacturer, at most, showed significant changes after the calibration process, decreasing variance and improving the accuracy of programmed volumes.
102

Desenvolvimento de protocolo biomédico de avaliação de tratamento de crianças com paralisia cerebral por meio do baropodômetro eletrônico computadorizado / Development of biomedical protocol of treatment assessment of children with cerebral palsy by means of computerized electronic baropodometer

Silva, Bruna Maria da 20 April 2016 (has links)
A encefalopatia crônica da infância não progressiva, comumente conhecida como paralisia cerebral (PC), trata-se de uma doença que afeta o sistema nervoso central e esta diretamente relacionada à prematuridade e a asfixia perinatal. As disfunções motoras causadas por essa afecção limitam as crianças a realizaram atividades e tarefas diárias, a partir dessa incapacidade tratamentos veem sido desenvolvidos e aplicados para melhorar a qualidade de vida desses indivíduos, como tratamentos cirúrgicos, medicamentosos, de adaptação e fisioterapêutico. No entanto, na prática, a avaliação desses pacientes, ainda é realizada através de escalas de pontuação, sendo subjetivas em sua maioria. Nesse sentido, foi realizado um estudo do tipo descritivo que teve como objetivo, desenvolver e sistematizar um protocolo biomédico de avaliação baropodométrica de tratamento para crianças com PC, como contribuição quantitativa ao repertório de métodos de avaliações já existentes. Foram incluídas na pesquisa, crianças com PC, ambos os sexos, na faixa etária dos dois aos 12 anos de idade, independente da topografia e do tônus muscular e que estavam em tratamento fisioterapêutico com o método PediaSuit e/ou fisioterapia convencional. Foram excluídos da pesquisa indivíduos com diagnóstico de mielomeningocele, doenças progressivas e/ou degenerativas e indivíduos que associaram outras terapias de tratamento, além da fisioterapia convencional e/ou PediaSuit. Compuseram a amostra do estudo 21 crianças, que foram avaliadas antes e durante os tratamentos fisioterapêuticos. No entanto, essas crianças foram avaliadas com a finalidade de determinar as possíveis fragilidades e vantagens no desenvolvimento do protocolo, no total foram realizados 91 testes. Algumas crianças precisaram do auxílio de um andador para se manter na postura em pé. Relativamente ao objetivo proposto, este foi alcançado e considerou-se que o Protocolo Biomédico de Avaliação de Tratamento de Crianças com PC por meio do Barapodômetro Eletrônico Computadorizado (PROBIOBEC) poderá ser utilizado para avaliar crianças em tratamento fisioterapêutico. Assim, concluiu-se que a sistematização alcançada no formato de um protocolo de aquisição de dados por meio do baropodômetro eletrônico computadorizado (BEC) pode ser um exame complementar quantitativo viável e útil para o acompanhamento do impacto de intervenções terapêuticas nessa classe clínica de população. Além disso, foram desenvolvidos quatro artigos, sendo um publicado na Revista Uniandrade e outro publicado no Congresso de Engenharia Biomédica – CBEB, ambos no ano de 2014, e outros dois em processo para publicação. / Chronic encephalopathy nonprogressive childhood, commonly known as cerebral palsy (CP), it is a disease that affects the central nervous system and is directly related to prematurity and perinatal asphyxia. The motor dysfunction caused by this condition limit children performed daily activities and tasks, from that failure treatments see been developed and applied to improve the quality of life of individuals, such as surgical treatments, medications, physical therapy and adaptation. However, in practice, the evaluation of these patients is still performed using rating scales, being largely subjective. In this sense, was performed a descriptive study that had as objective develop and systematize a biomedical protocol baropodometric evaluation of treatment for children with CP as quantitative contribution to the repertoire of existing ratings methods. Were included in the study, children with CP, both sexes, aged from two to 12 years of age, regardless of topography and muscle tone, and that were in physical therapy with PediaSuit method and / or conventional physical therapy. Were excluded from the research individuals diagnosed with myelomeningocele, progressive disease and / or degenerative and individuals associated with other therapies treatment in addition to conventional therapy and / or PediaSuit. Comprised the sample of the study 21 children who were evaluated before and during physical therapy treatments.However, these children were evaluated in order to determine possible fragility and advantages in the development of the protocol, in total were carried out 91 tests. Some children needed the aid of a walker to stay in the standing posture. Regarding the proposed objective, this was achieved and it was considered that the Protocol Biomedical Treatment Assessment of Children with PC by means of Barapodômetro Electronic Computerized (PROBIOBEC) can be used to assess children in physical therapy. Thus, it was concluded that the systematization achieved in the format of a data acquisition protocol by means of computerized electronic baropodômetro (BEC) can be a viable quantitative further examination and useful for monitoring the impact of therapeutic interventions in this clinical class population. In addition, four articles were developed, one published in the Journal Uniandrade and another published in Congress of Biomedical Engineering - CBEB, both in 2014, and two more in the process of publication. Thus, it was concluded that the systematization achieved in the format a data acquisition protocol by means of computerized electronic baropodômetro (BEC) can be a viable quantitative complementary examination and useful for monitoring the impact of therapeutic interventions in this clinical class population. In addition, four articles were developed, one published in the Journal Uniandrade and another published in Congress of Biomedical Engineering - CBEB, both in 2014, and two more in the process of publication.
103

Avaliação das emissões conduzidas e radiadas geradas por unidade eletrocirúrgica e sistema de iluminação com lâmpadas fluorescentes em equipamentos médicos

Moraes, Fábio Brignol de 16 December 2013 (has links)
Este trabalho apresenta um estudo sobre interferência eletromagnética, emissões radiada e conduzida, gerados pelo sistema de iluminação e pela unidade de eletrocirurgia (bisturi eletrônico) numa sala cirúrgica de um hospital da cidade de Pato Branco/PR. O trabalho consistiu em medidas de emissões conduzidas e radiadas de sistemas de iluminação fluorescentes em laboratório e de emissões conduzidas e radiadas “in loco” da unidade de eletrocirurgia. Além disso, foi feito estudo de referenciais sobre as normas, nacionais e internacionais, que incidem sobre estes dois sistemas. Como resultado do trabalho tem-se um panorama sobre a situação das emissões conduzidas e radiadas, pelos sistemas de iluminação fluorescente e unidade eletrocirúrgica utilizados no hospital. / This work presents a study on electromagnetic interference radiated and conducted emissions generated by the lighting system and the electrosurgery unit (eletric scalpel) in na operating room of a hospital in Pato Branco / PR. The work consisted of measurements of conducted and radiated emission of fluorescent lighting systems in the laboratory of conducted and radiated “in loco” electrosurgery unit emissions. Futhermore, a study was made of references on standarts, national and international, that focus on these two systems. Because of the work, has an overview on the situation of conducted and radiated emissions, the fluorecent lighting used in electrosurgical unit and hospital systems.
104

Análise dosimétrica em pediatria neonatal

Bunick, Ana Paula 31 March 2014 (has links)
Exames radiográficos do tórax são frequentemente solicitados para pacientes recém-nascidos internados na Unidade de Terapia Intensiva (UTI) Neonatal. Entretanto, as crianças são mais radiossensíveis quanto menor a idade que possuem e devido ao maior número de células em processo de replicação. Essa característica acaba despertando uma maior preocupação da comunidade científica em conhecer a dose de radiação a que são expostos esses pacientes pediátricos. Este trabalho descreve a metodologia aplicada para a execução de uma análise dosimétrica em pediatria neonatal no Hospital Infantil Pequeno Príncipe, em Curitiba. Inicialmente, o trabalho propõe a construção de um objeto simulador de um recém-nascido para consequentes medidas de dose de radiação recebida pelo paciente neonato, através do uso de TLDs (Dosímetros Termoluminescentes) para medidas de ESAK (Kerma-ar na Superfície de Entrada) sob a região torácica e medida de kerma-ar na profundidade do pulmão, na água, com o uso de uma câmara de ionização. Também foi avaliada a dose de radiação espalhada recebida pelo paciente internado próximo ao paciente examinado. Os resultados da pesquisa mostraram, em geral, níveis de dose abaixo dos valores de referência para as medidas de ESAK. Para as medidas de kerma-ar na profundidade do pulmão, os valores encontrados e comparados com cálculos de dose-órgão por meio de um software mostraram-se abaixo dos valores obtidos com os TLDs. As medidas de radiação espalhada mostraram que os pacientes próximos ao paciente examinado recebem uma pequena faixa de contribuição de dose durante os exames. / Chest radiographic examinations are frequently requested for newborn patients hospitalized in a Intensive Care Unit (ICU) Neonatal. However, children are more radiosensitive the younger they are and due to the higher number of cells in replication process. This feature arises greater concern in the scientific community to know the dose of radiation that these pediatric patients are exposed. This paper describes the methodology used for the implementation of a dosimetric analysis in neonatal pediatrics at the Children's Hospital Pequeno Príncipe, in Curitiba. Initially, the work proposes the construction of a phantom of a newborn to subsequent measurement of the radiation dose received by the neonate patient, through the use of TLDs (Thermoluminescent Dosimeters) for measures ESAK (Entrance Surface Air-Kerma) in the thoracic region and measure kerma-air in the deep lung, in water, with the use of an ionization chamber. The scattered radiation dose received by another patient near the patient under examination was also evaluated. The results showed, in general, dose levels below the reference values for the measures ESAK. For the kerma- air in the deep lung, and the values obtained compared to organ dose calculations through software is shown to be below the values obtained with TLDs. The measurements showed that the scattered radiation near the patient examined receive a small contribution of dose during examinations.
105

Máquinas lavadoras ultrassônicas de instrumentos odontológicos, médicos e cirúrgicos: avaliação do desempenho do processo de limpeza

Albrecht, Lucimara 28 February 2013 (has links)
A limpeza de instrumentos odontológicos, médicos e cirúrgicos (IOMC) em máquina lavadora ultrassônica (MLUS) utiliza energia mecânica (vibrações sonoras - cavitação), química (soluções detergentes) e térmica (temperatura) associadas ao tempo de exposição. A eficácia deste processo é certificada por meio de testes de controle recomendados por normas internacionais. Neste estudo buscou-se avaliar o desempenho da MLUS quanto aos parâmetros mínimos aceitáveis nas condições práticas de uso através de testes descritos em normas e discutir os fatores de interferência durante o processo que podem comprometer a eficiência da limpeza dos IOMC. Uma pesquisa inicial analisou as condições operacionais da MLUS por meio de questionário auto-aplicado nos estabelecimentos assistenciais à saúde (EAS) de Curitiba mostrando amplo uso da MLUS, com procedimentos técnicos de preparo do processo de limpeza, relação de tempo/temperatura e perfil dos ciclos com a carga de acordo com recomendações da literatura. Entretanto, não houve consenso sobre testes e normas técnicas a serem aplicadas. Assim, foram realizados testes de tiras e folhas de alumínio, indicadores químicos Sono Check® e TOSI® Lum Check para instrumentais canulados baseados em normas internacionais. Os resultados mostraram que todas as folhas de alumínio testadas apresentaram padrão uniforme de perfurações (100%), indicando a eficiência da cavitação. Nas tiras de folhas de alumínio houve perfurações semelhantes na maioria delas (89%) e uma apresentou poucas alterações (11%) apontando falhas no teste e/ou no funcionamento do equipamento. Em 3 testes de indicadores químicos Sono Check® foi obtido resultado positivo (37,5%), em outros três houve demora na alteração da cor mas acabaram positivos (37,5%) e dois indicadores de 2 testes não alteraram a cor (25%). Os resultados positivos (75%) comprovaram a eficácia da atividade ultrassônica e os negativos indicaram pontos cegos no processo de cavitação, o que pode ser atribuído a fatores interferentes na limpeza como: uso da mesma solução de limpeza em vários ciclos, tipo e disposição da carga, nível de preenchimento da solução no tanque, temperatura e divergência das ondas ultrassônicas entre instrumentais e paredes do equipamento. Os resultados dos testes TOSI® Lum Check foram negativos pois apresentaram resíduos de fibrina na superfície das placas de aço que pode estar relacionado a um reduzido tempo de exposição, temperatura não adequada, qualidade da água, diluição incorreta da solução de limpeza, teste mal posicionado, sobrecarga e/ou carga incorreta de IOMC e ineficiência da solução limpante. Concluiu-se que os testes de controle comprovam a eficácia da atividade ultrassônica na limpeza e detectam falhas no desempenho da MLUS atribuídas a fatores interferentes citados e para tanto é recomendado a elaboração de uma norma técnica no Brasil com a implementação da monitoração da atividade ultrassônica para a garantia da qualidade do processo de limpeza ultrassônica. / The cleaning of dental, medical and surgical instruments (DMSI) with ultrasonic cleaning equipment (UCE) makes use of mechanical (sound vibrations – cavitation), chemical (detergent solutions) and thermal (temperature) energies associated with exposure time. To check the performance of the cleaning process it is necessary the use of tests recommended by international standards. In this study we have evaluated the performance of UCE concerning its minimal acceptable parameters by means of tests described on standards as well as discussing the interfering factors which could compromise the cleaning process of DMSI. Initially, a survey analyzed the operating conditions of UEC through a questionnaire answered by professionals of several health care establishments (HCE) of Curitiba city. The results showed wide use of UCE in the investigated HCE, technical procedures for preparation of the cleaning process, time/temperature relationship and load cycle profiles according to literature recommendations. However there was no agreement on the type test selection or adoption of technical standards. Considering those results, practical tests were carried out for aluminium foils and strips, Sono Check® chemical indicators and TOSI® Lum Check for cannulated instruments, based on international standards. Aluminium foils (100%) and strips (89%) have showed uniformity in the produced holes, indicating efficiency of the cavitation. Some strips presented few modifications (11%), indicating failures in the test and/or functioning of the equipment. Chemical indicators Sono Check®| presented positive results (75%) proving the effectiveness of ultrasonic activity, however some (25%) presented negative results indicating blind spots due to difficulties in the cavitation process, which can be attributed to interfering factors such as: use the same cleaning solution in several cycles, type and disposition of the load, level of the solution in the tank, temperature and divergence of ultrasonic waves between instrument and walls of the equipment. TOSI® Lum Check for cannulated instruments showed negative results which can be attributed to reduced exposure time, not adequate temperature, water quality, incorrect dilution of the cleaning solution, test bad positioned, overload and/or incorrect load of the instruments, and inefficiency of the cleaning solution. It was concluded that the control tests can prove the effectiveness of the ultrasound in the cleaning activity and detect performance failures for UCE assigned to the cited interfering factors. Therefore, it is recommended the development of a technical standard in Brazil which should include types of tests, procedures and operational control of the cycle parameters in order to ensure the quality control of the ultrasonic cleaning process.
106

Avaliação estatística e protocolo para uso de cateter central de inserção periférica na oncohematologia / Statistical evaluation and protocol for use of peripherally inserted central catheter in oncohematology

Oliveira, Edinaldo Silva de 18 April 2017 (has links)
O Cateter Central de Inserção Periférica (PICC) constitui-se de dispositivo intravenoso, instalado através de uma veia periférica, que avança até a veia cava adquirindo características de cateter central. Neste sentido, o presente estudo teve como objetivo geral: identificar as condições de viabilidade para a definição de padrões e protocolos que possibilitem a utilização do PICC em pacientes adultos e pediátricos. E como objetivos específicos: analisar o desempenho da primeira e terceira geração de PICC em pacientes da oncohematologia comparando com a literatura internacional; detectar pontos sensíveis no contexto do uso do PICC para a proposição de protocolo; propor instrumento para a coleta e investigação de relevância de dados e variáveis; e propor protocolo de utilização do PICC para pacientes pediátricos e adultos. Trata-se de estudo descritivo exploratório observacional prospectivo longitudinal com abordagem quantitativa. A pesquisa foi desenvolvida na Unidade de Hemoterapia, Hematologia e Oncologia (UHHO) nos setores: Serviço de Transplante de Medula Óssea (STMO), Quimioterapia de Alto Risco (QTAR) e seus ambulatórios, Unidade de Terapia Intensiva (UTI) cardíaca, clínica médica e pediátrica, num hospital de ensino da região do sul do país. A amostra foi não-probabilística, por conveniência constituída de dois grupos, (Grupo 1) pacientes que utilizaram a primeira geração do PICC e (Grupo 2) pacientes que utilizaram a terceira geração do dispositivo. Os dados foram coletados no período de janeiro de 2015 a agosto de 2016 através de instrumento elaborado para este estudo, contendo 22 variáveis sócio-demográficas e 35 variáveis clínicas. 40 PICCs primeira geração foram inseridos em 36 pacientes por técnicas “às cegas”, totalizando 830 dias de cateter, média de 20,71 dias, tendo alcance mínimo de dois e máximo de 141 dias. Quanto à terceira geração do cateter, dez PICCs foram inseridos em dez pacientes por Técnica de Seldinger Modificada (TSM) guiados pelo Ultrassom (US), totalizando 397 dias de cateter, média de 39,7 dias com alcance mínimo de dez e máximo de 86 dias. Realizou-se análise descritiva por meio da distribuição de frequência absoluta, média e desvio padrão. Posteriormente, todas as variáveis foram analisadas pelo ‘Software R’, identificou-se 11 componentes principais que fortemente se relacionaram e constituíram a base do Modelo de Equações Estruturais (MEE). Estas variáveis expressam-se de maneira relevante para o desenvolvimento de investigações futuras. Em suma, o PICC pode ser utilizado com sucesso na maioria dos pacientes internados na oncohematologia e em outros setores no ambiente hospitalar, assim como em crianças. Pode ser inserido por enfermeiros, desonerando o ambiente cirúrgico, processo anestésico e o médico especialista, conferindo-lhes autonomia. / The Peripherally Inserted Central Catheter (PICC) consists of an intravenous device, installed through a peripheral vein, wich advanced to the vena cava acquiring central catheter characteristics. In this sense, the present study had as general objective: to identify the feasibility conditions for the definition of standards and protocols that allow the use of PICC in adult and pediatric patients. And as specific objectives: to analyze the performance of the first and third generation of PICC in oncohematology patients comparing with the international literature; to detect sensitive points in the context of the use of the PICC for the protocol proposal; propose an instrument for the collection and relevant investigation of data and variables; and to propose protocol of use of PICC for pediatric and adult patients. This is a descriptive prospective longitudinal observational exploratory study with a quantitative approach. The research was developed in the Hematology, Oncology and Hematology Unit (UHHO) in the following sectors: Bone Marrow Transplantation Service (STMO), High Risk Chemotherapy (QTAR) and its outpatient clinics, Intensive Care Unit (ICU), cardiac, medical clinic and pediatric in a teaching hospital in the southern region of the country. The sample was non-probabilistic, for convenience consisted of two groups, (Group 1) patients who used the first generation of PICC and (Group 2) patients who used the third generation of the device. Data were collected from January 2015 to August 2016 through an instrument developed for this study, containing 22 socio-demographic variables and 35 clinical variables. 40 firstgeneration PICCs were inserted in 36 patients by "blind" techniques, totaling 830 days of catheter, average of 20.71 days, with a minimum range of two and a maximum of 141 days. Regarding the third generation of the catheter, ten PICCs were inserted in ten patients by Ultrasound-guided Modified Seldinger Technique (TSM), totaling 397 days of catheter, mean of 39.7 days with a minimum range of ten and a maximum of 86 Days. A descriptive analysis was performed by means of the absolute frequency distribution, mean and standard deviation. Afterwards, all variables were analyzed by 'Software R', we identified 11 main components that were strongly related and formed the basis of the Structural Equations Model (MEE). These variables express themselves in a relevant way for the development of future investigations. In summary, PICC can be used successfully in most patients admitted to oncohematology and other sectors in the hospital setting, as well as in children. It can be inserted by nurses, discharging the surgical environment, anesthetic process and the specialist doctor, granting them autonomy.
107

Sistema telemétrico com tecnologia RFID para medição de pressão

Luis, Hamilton Costa 17 September 2010 (has links)
A necessidade da medicina por equipamentos eletrônicos portáteis, menores, confiáveis e baratos favorece o desenvolvimento de técnicas biotelemétricas passivas de monitoração nas aplicações biomédicas invasivas. Nesse trabalho são apresentados o desenvolvimento e o teste de um dispositivo sensor biotelemétrico passivo, que utiliza a tecnologia de identificação por radio freqüência - RFID (Radio Frequency Identification). O dispositivo desenvolvido, comumente chamado como tag, é comporto basicamente por três partes: a arquitetura RFID utilizada para baixa freqüência, a unidade de controle responsável pelo processamento dos dados e a unidade sensora responsável pela monitoração da pressão arterial. Como o tag e passivo, ou seja, não contém baterias, para que seja ativado é necessário um aparelho que faça sua energização e também decodifique os dados por ele transmitidos. Este aparelho que faz a leitura e envia um sinal para ativar o transponder é comumente chamado de leitora. A leitora utilizada neste projeto terá seu firmware adaptado de forma a processar o valor da pressão enviada pelo tag. São abordados neste trabalho tanto a modelagem teórica do sistema quanto a especificação prática dos componentes para os testes de validação. Na modelagem teórica são apresentados os modelos matemáticos comportamentais do sistema. Os resultados obtidos validam a metodologia utilizada para o desenvolvimento de um sensor RFID passivo que tem como finalidade mensurar a pressão arterial. / The need of medicine for portable electronic equipments smallers [sic], reliables [sic] and inexpensive supports the development of biotelemetry techniques passive monitoring in invasive biomedical applications. In this work are presents [sic] the development and testing of a passive biotelemetry sensor device, which uses the technology of Radio Frequency Identification - RFID. The developed device, commonly referred to as the tag, is basically composed of three parts: the RFID architecture used for low frequency, the control unit responsible for data processing and sensor unit responsible for monitoring blood pressure. As the tag is passive i.e. does not contain batteries to activate it, It [sic] is necessary a device that makes its energizing and also decode the data transmitted by it. This device that reads and sends a signal to activate the transponder is commonly called a reader. The reader used in this project will have its firmware adapted to handle the pressure value sent by the tag. This work also presents theoretical modeling of the system and the specification of components for practicing the validation tests. In theoretical modeling are presented mathematical models of system behavior. The results validate the methodology used for the development of passive RFID sensor that aims to measure blood pressure.
108

Estudo metrológico volumétrico de bombas de infusão peristálticas lineares / Volumetric metrological study of peristaltic linear infusion pump

Dumas Junior, Adair 18 August 2016 (has links)
O presente estudo consiste em analisar se o sistema atual de calibração das bombas de um determinado fabricante, baseado na entrada de parâmetros externos e consequente readequação interna por software é adequado para a correção dos volumes infundidos. A literatura carece de estudos sobre bombas de infusão peristálticas lineares, principalmente estudos metrológicos relacionados aos volumes infundidos. Esta carência relaciona-se entre outros fatores, pelos elevados custos das bombas de infusão, bem como à grande quantidade de horas de ensaios necessárias. Para isso, foram analisados os volumes infundidos em taxas mínima, intermediária e máxima de três bombas de infusão peristálticas lineares retiradas aleatoriamente de um hospital no estado do Paraná, que não passavam por manutenção havia exatos doze meses e estavam em uso contínuo no estabelecimento. Foram realizados ensaios em taxa fixa de 25 ml/h em 5 volumes diferentes ao longo da faixa habitual de uso. Também foram feitos ensaios em volume fixo de 10 ml variando-se a taxa de infusão entre 1 ml/h, 25 ml/h e 100 ml/h. Para análise estatística dos resultados, foi feito um teste de normalidade de Anderson-Darling, como a maioria dos resultados não apresentaram características de normalidade, foi feito uma análise do intervalo de confiança das medianas para análise dos resultados. Também foi necessário fazer uma ANOVA para verificação da influência das bombas e das taxas no volume infundido, seguido por uma análise de curva de erros e uma planilha para o cálculo de incertezas das medições. Foi possível verificar que os volumes infundidos pelas bombas deste fabricante, em sua maioria apresentaram mudanças significativas após o processo de calibração, com diminuição na variância e melhora na exatidão dos volumes programados. / This study examined whether the current system calibration of the pumps from a particular manufacturer, based on the input of external parameters and consequent internal readjustment by software, is suitable for the correction of infused volumes. The literature lacks studies on linear peristaltic pump infusion, especially metrological studies related to the infused volume. This deficiency relates among other factors, the high costs of infusion pumps as well as the large amount of hours required for testing. Therefore, the volumes were analyzed by infusing at minimum, intermediate and maximum rates of three linear peristaltic infusion pumps randomly taken from a hospital in the state of Paraná, which had not have maintenance in the latest 12 months and were in continuous use at the hospital. Assays were performed in flat rate of 25 ml / h in 5 different volumes over the usual range of use. Tests at a fixed volume of 10 ml varying the infusion rate at 1 ml/h, 25 ml/h and 100 ml/h were also made. For statistical analysis, an Anderson-Darling normality test was done, as most of the results did not show normal characteristics, an analysis of the confidence interval of the median for analysis of results was done. It was also necessary to do an ANOVA to check the influence of pumps and rates of infused volume, followed by a curve error analysis and a spreadsheet to calculate the measurements uncertainties. It was possible to verify that the volumes infused by the bombs from this manufacturer, at most, showed significant changes after the calibration process, decreasing variance and improving the accuracy of programmed volumes.
109

Desenvolvimento de protocolo biomédico de avaliação de tratamento de crianças com paralisia cerebral por meio do baropodômetro eletrônico computadorizado / Development of biomedical protocol of treatment assessment of children with cerebral palsy by means of computerized electronic baropodometer

Silva, Bruna Maria da 20 April 2016 (has links)
A encefalopatia crônica da infância não progressiva, comumente conhecida como paralisia cerebral (PC), trata-se de uma doença que afeta o sistema nervoso central e esta diretamente relacionada à prematuridade e a asfixia perinatal. As disfunções motoras causadas por essa afecção limitam as crianças a realizaram atividades e tarefas diárias, a partir dessa incapacidade tratamentos veem sido desenvolvidos e aplicados para melhorar a qualidade de vida desses indivíduos, como tratamentos cirúrgicos, medicamentosos, de adaptação e fisioterapêutico. No entanto, na prática, a avaliação desses pacientes, ainda é realizada através de escalas de pontuação, sendo subjetivas em sua maioria. Nesse sentido, foi realizado um estudo do tipo descritivo que teve como objetivo, desenvolver e sistematizar um protocolo biomédico de avaliação baropodométrica de tratamento para crianças com PC, como contribuição quantitativa ao repertório de métodos de avaliações já existentes. Foram incluídas na pesquisa, crianças com PC, ambos os sexos, na faixa etária dos dois aos 12 anos de idade, independente da topografia e do tônus muscular e que estavam em tratamento fisioterapêutico com o método PediaSuit e/ou fisioterapia convencional. Foram excluídos da pesquisa indivíduos com diagnóstico de mielomeningocele, doenças progressivas e/ou degenerativas e indivíduos que associaram outras terapias de tratamento, além da fisioterapia convencional e/ou PediaSuit. Compuseram a amostra do estudo 21 crianças, que foram avaliadas antes e durante os tratamentos fisioterapêuticos. No entanto, essas crianças foram avaliadas com a finalidade de determinar as possíveis fragilidades e vantagens no desenvolvimento do protocolo, no total foram realizados 91 testes. Algumas crianças precisaram do auxílio de um andador para se manter na postura em pé. Relativamente ao objetivo proposto, este foi alcançado e considerou-se que o Protocolo Biomédico de Avaliação de Tratamento de Crianças com PC por meio do Barapodômetro Eletrônico Computadorizado (PROBIOBEC) poderá ser utilizado para avaliar crianças em tratamento fisioterapêutico. Assim, concluiu-se que a sistematização alcançada no formato de um protocolo de aquisição de dados por meio do baropodômetro eletrônico computadorizado (BEC) pode ser um exame complementar quantitativo viável e útil para o acompanhamento do impacto de intervenções terapêuticas nessa classe clínica de população. Além disso, foram desenvolvidos quatro artigos, sendo um publicado na Revista Uniandrade e outro publicado no Congresso de Engenharia Biomédica – CBEB, ambos no ano de 2014, e outros dois em processo para publicação. / Chronic encephalopathy nonprogressive childhood, commonly known as cerebral palsy (CP), it is a disease that affects the central nervous system and is directly related to prematurity and perinatal asphyxia. The motor dysfunction caused by this condition limit children performed daily activities and tasks, from that failure treatments see been developed and applied to improve the quality of life of individuals, such as surgical treatments, medications, physical therapy and adaptation. However, in practice, the evaluation of these patients is still performed using rating scales, being largely subjective. In this sense, was performed a descriptive study that had as objective develop and systematize a biomedical protocol baropodometric evaluation of treatment for children with CP as quantitative contribution to the repertoire of existing ratings methods. Were included in the study, children with CP, both sexes, aged from two to 12 years of age, regardless of topography and muscle tone, and that were in physical therapy with PediaSuit method and / or conventional physical therapy. Were excluded from the research individuals diagnosed with myelomeningocele, progressive disease and / or degenerative and individuals associated with other therapies treatment in addition to conventional therapy and / or PediaSuit. Comprised the sample of the study 21 children who were evaluated before and during physical therapy treatments.However, these children were evaluated in order to determine possible fragility and advantages in the development of the protocol, in total were carried out 91 tests. Some children needed the aid of a walker to stay in the standing posture. Regarding the proposed objective, this was achieved and it was considered that the Protocol Biomedical Treatment Assessment of Children with PC by means of Barapodômetro Electronic Computerized (PROBIOBEC) can be used to assess children in physical therapy. Thus, it was concluded that the systematization achieved in the format of a data acquisition protocol by means of computerized electronic baropodômetro (BEC) can be a viable quantitative further examination and useful for monitoring the impact of therapeutic interventions in this clinical class population. In addition, four articles were developed, one published in the Journal Uniandrade and another published in Congress of Biomedical Engineering - CBEB, both in 2014, and two more in the process of publication. Thus, it was concluded that the systematization achieved in the format a data acquisition protocol by means of computerized electronic baropodômetro (BEC) can be a viable quantitative complementary examination and useful for monitoring the impact of therapeutic interventions in this clinical class population. In addition, four articles were developed, one published in the Journal Uniandrade and another published in Congress of Biomedical Engineering - CBEB, both in 2014, and two more in the process of publication.
110

Automated Channel Assessment for Single Chip MedRadio Transceivers

Hillig, Mark Alexander 14 June 2013 (has links)
Modern implantable and body worn medical devices leverage wireless telemetry to improve patient experience and expand therapeutic options. Wireless medical devices are subject to a unique set of regulations in which monitoring of the available frequency spectrum is a requirement. To this end, implants use software protocols to assess the in-band activity to determine which channel should be used. These software protocols take valuable processing time and possibly degrade the operational lifetime of the battery. Implantable medical devices often take advantage of a single chip transceiver as the physical layer for wireless communications. Embedding the channel assessment task in the transceiver hardware would free the limited resources of the microprocessor. This thesis proposes hardware modifications to existing transceiver architectures which would provide an automated channel assessment means for implantable medical devices. The results are applicable beyond medical device applications and could be employed to benefit any low-power, wireless, battery-operated equipment.

Page generated in 0.0851 seconds