• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • 92
  • 3
  • 1
  • Tagged with
  • 233
  • 233
  • 94
  • 82
  • 81
  • 79
  • 41
  • 36
  • 25
  • 22
  • 19
  • 17
  • 16
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudio gammagráfico de la disfunción de las glándulas salivales en pacientes con cáncer diferenciado de tiroides tratados con yodo radiactivo I-131 en el Hospital Guillermo Almenara Lima-Perú julio de 2012 a diciembre del 2012

Flores Barrenechea, Brisaida Isabel January 2013 (has links)
Publicación a texto completo no autorizada por el autor / Determina la utilidad del estudio gammagráfico en la disfunción de glándulas salivales en los pacientes que reciben yodo radiactivo por cáncer tiroideo. El presente trabajo se realiza atendiendo la elevada frecuencia de cáncer tiroideo con indicación de terapia de yodo radiactivo que son trtatados en el hospital Guillermo Almenara y la presencia de efectos adversos como el daño de glándulas salivales a pesar de las medidas profiláticas convencionales (sialogogos). La terapia con yodo radiactivo es un procedimiento no invasivo y de uso frecuente en los servicios de medicina nuclear. / Trabajo académico
22

Simula??es de Monte Carlo para o estudo da dosimetria interna em imagens de medicina nuclear de mulheres gr?vidas / Monte Carlo simulations for the study of internal dosimetry of nuclear medicine imaging of pregnant women

Dartora, Caroline Machado 29 March 2017 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-06-30T17:45:25Z No. of bitstreams: 1 DIS_CAROLINE_MACHADO_DARTORA_COMPLETO.pdf: 2382956 bytes, checksum: 7909b8673eceb86e85c844ad70245e3b (MD5) / Made available in DSpace on 2017-06-30T17:45:25Z (GMT). No. of bitstreams: 1 DIS_CAROLINE_MACHADO_DARTORA_COMPLETO.pdf: 2382956 bytes, checksum: 7909b8673eceb86e85c844ad70245e3b (MD5) Previous issue date: 2017-03-29 / The statistical nature of the physical process involved in Nuclear Medicine exams makes the use of Monte Carlo methods an useful tool for deposited energy and absorbed dose calculations on organs, mainly for risk-benefits assessment. Pregnant are important target for risk-benefit assessment, due the fetus exposure to radiation. Nuclear Medicine exams may generate fetus dose, either by irradiation due to maternal organs, or by activity that crosses the placenta and accumulates in fetus. Usually, both internal dosimetry estimation software and virtual anthropomorphic simulators are proprietary. The aim of this research is to investigate the use of GATE (Geant4 Application for Emission Tomography) application of Monte Carlo method on internal dosimetry calculation in simulated Nuclear Medicine image exams in pregnant woman. First, an evaluation of the use of GATE was performed to build dose maps with simple geometries. An evaluation of the radiation interaction behavior with respect to available GATE source types of configuration of single photon (99mTc) and positrons (18F) emitters was also performed. Dose estimation on a fetus was performed by simulation of a [18F] FDG distribution in a virtual 24-week pregnant woman simulator, Katja, with data based on literature. It was evaluated the impact on fetal dose of the mother bladder uptake of , placenta uptake, maternal organs irradiation and dose generated due to the uptake only in the fetus. The total estimated dose for a fetus on 24 weeks was 0.0122 mGy/MBq, in agreement with published data. Several individual dose contributions in the fetus that are not commonly found in the literature, such as the contribution due to the bladder (13%) and placenta (0.53%) were obtained. The contribution in total fetal dose of the activity only in the organs of the fetus was analyzed, resulting in 3.8%, where 56% is due only to positron emitted by the source. In conclusion, GATE generates dose maps that can be used as a method of dose estimation in pregnant women in MN scans, giving detailed information about the individual contributions of maternal organs uptake. / A natureza estat?stica dos processos f?sicos nos exames de Medicina Nuclear faz com que o uso de m?todos de Monte Carlo seja ?til para c?lculos da energia depositada e da dose absorvida nos ?rg?os, principalmente para avalia??o de risco-benef?cio. Gr?vidas s?o um alvo importante para avalia??o risco-benef?cio devido ? exposi??o do feto ? radia??o. Exames de Medicina Nuclear podem gerar dose no feto, tanto pela irradia??o devido ? atividade nos ?rg?os maternos, como pela atividade que atravessa a placenta e se acumula no feto. Usualmente, os softwares de estimativa de dosimetria interna e os simuladores antropom?rficos virtuais s?o propriet?rios. O objetivo desta pesquisa ? investigar o uso do aplicativo gratuito de simula??o de Monte Carlo denominado GATE (Geant4 Application for Emission Tomography), no c?lculo da dosimetria interna em exames simulados de Medicina Nuclear em mulheres gr?vidas. Inicialmente, foi realizada uma avalia??o do uso do GATE na constru??o de mapas de dose com geometrias simples e o comportamento para diferentes configura??es dos tipos de fontes no aplicativo para emissores de f?ton ?nico (99mTc) e p?sitrons (18F). A estimativa de dose no feto foi realizada atrav?s da simula??o de uma distribui??o de [18F]FDG em um simulador virtual gratuito de mulher gr?vida de 24 semanas, denominada Katja, com distribui??o de atividade baseada na literatura. Foi investigado o impacto, na dose fetal total, da capta??o e esvaziamento da bexiga da m?e, da placenta, da irradia??o do feto pelos ?rg?os maternos e dose gerada devido ? atividade captada somente pelo feto. A dose estimada total para um feto de 24 semanas foi de 0,0122 mGy/MBq, estando de acordo com a m?dia dos trabalhos publicados. Obtiveram-se contribui??es individuais ? dose no feto que n?o s?o comumente encontradas na literatura, tais como a dose devido ? bexiga (13%) e ? placenta (0,53%). Foi analisada a contribui??o da atividade captada somente nos ?rg?os do feto na dose total no feto, que resultou em 3,8%, sendo que 56% correspondem ? dose devido aos p?sitrons emitidos pela fonte. Conclui-se que o aplicativo GATE gera mapas de dose que podem ser utilizados como um m?todo de estimativa de dose de mulheres gr?vidas em imagens de Medicina Nuclear, fornecendo informa??es detalhadas das contribui??es individuais da capta??o nos ?rg?os da m?e ? dose.
23

Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m / Comparison study among methodologies of planar chromatography for radiochemical control of Tecnécio-99m radiopharmaceuticals

Monteiro, Elisiane de Godoy 26 April 2012 (has links)
Os radiofármacos são substâncias que possuem radioisótopos em sua composição. Cerca de 95% dos procedimentos realizados em medicina nuclear faz o uso de radiofármacos com finalidade diagnóstica, sendo os reagentes liofilizados (RL) marcados com Tecnécio-99 meta estável (99mTc), obtido a partir de um gerador de 99Mo/99mTc, os mais utilizados. O controle de qualidade representa o conjunto de ensaios a serem realizados para certificar que o produto é adequado ao propósito. Um aspecto importante a ser avaliado nos radiofármacos de 99mTc é a pureza radioquímica (% PRq) para quantificação de pertecnetato livre (99mTcO4 -) e tecnécio coloidal (99mTcO2), principalmente por cromatografia em papel (CP), em camada delgada (CCD) e cromatografia líquida de alta eficiência (CLAE). O objetivo deste trabalho foi realizar a comparação das metodologias de controle radioquímico de RL marcados com 99mTc descritas nas farmacopéias americana (FA) e europeia (FE) com aquelas utilizadas no IPEN. O eluído de 99mTcO4 e os RL: DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH e Sn Coloidal foram provenientes do IPEN-CNEN/SP. Foram utilizados os suportes cromatográficos TLC-celulose, TLC-SG,TLC-SG fase reversa, HPTLC-celulose e HPTLC-SG da Merck e ITLC-SG da Pall Corporation, W1MM, W3MM, W17M e W31ET da Whatman. A contagem da radioatividade foi feita em contador gama Perkin Elmer modelo Cobra D-5002. A marcação dos RL foi feita de modo a obter concentração radioativa de 55,0 MBq mL-1 (1,5 mCi mL-1). Foram determinadas as %99mTcO4 -, %99mTcO2 e % PRq até 4 horas de marcação. Dos 11 RL, apenas EC e GHA não possuem método de controle radioquímico na FA e FE. Na FA e/ou na FE, os métodos para DTPA, MDP, PIRO, SAH e Sn Coloidal utilizam ITLC-SG; no IPEN, este suporte cromatográfico é utilizado em DISIDA, EC, ECD, GHA, PIRO, MIBI e SAH. Devido à descontinuidade na fabricação de ITLC-SG (recomendado em 40, 70 e 41% das metodologias da FA, FE e IPEN, respectivamente), foi necessário buscar alternativas para sua substituição no controle radioquímico, avaliando-se suportes do tipo HPTLC (celulose e sílica gel) e Whatman (com diferenças de espessura e fluxo de corrida). Os resultados de % PRq determinada pelos métodos descritos na FA, FE, IPEN e os demais sistemas avaliados que apresentaram coeficiente de variação menor que 5% não foi considerada diferença significativa entre os métodos. Os sistemas cromatográficos avaliados neste trabalho podem ser utilizados em substituição ao suporte ITLC-SG. O HPTLC-celulose foi o suporte que apresentou tempo de análise, perfil cromatográfico e custo semelhante ao ITLC-SG, tornando-o um dos suportes mais indicados a ser utilizado como alternativa ao ITLC-SG nos 11 RL avaliados. / Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic pruposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m (99mTc), obtained from 99Mo/99mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in 99mTc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate (99mTcO4 -) and technetium colloidal (99mTcO2) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perfom the comparison among the radiochemical control methodologies of LR labeled with 99mTc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. 99mTcO4 - eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-celulose, TLC-SG,TLC-SG reverse phase, HPTLC-celulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL-1 (1,5 mCi mL-1) of final radioactive concentration. The %99mTcO4 -, %99mTcO2 and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was necessary to search alternatives to replace ITLC-SG plate in the radiochemical control, comparing with HPTLC (cellulose and silica gel) and Whatman plates (with thickness and flow rate differences). The % RqP results determined by the methods described in USP, EP, IPEN and the methods evaluated in this work presented coefficient of variation less than 5%, and it was not considered a significant value among the methods. Some chromatographic systems evaluated in this work can be used as replacement to the ITLC-SG plate. HPTLC-cellulose was the plate that presented time of analysis chromatography profile and cost similar to ITLC-SG, making it one of the most indicated to replace ITLC-SG, in 11 LR evaluated.
24

Estudo do tempo de excreção renal através da cintilografia em felinos domésticos / Evaluation of renal excretion using scintigraphy in domestic cats

Jarretta, Georgea Bignardi 04 August 2005 (has links)
Na rotina clínica de felinos domésticos, algumas modalidades de diagnóstico por imagem, como a ultra-sonografia, radiografia simples e urografia excretora, já são amplamente utilizadas. A cintilografia é uma técnica não invasiva, capaz de oferecer informações funcionais de rins individualmente, porém é considerada uma modalidade menos usual. O objetivo deste estudo foi determinar o tempo de excreção renal de felinos domésticos através da cintilografia, em animais com parâmetros ultra-sonográficos e radiográficos dentro dos limites da normalidade. Foram utilizados 15 animais, 9 machos e 6 fêmeas, e estes foram divididos em grupos de animais não submetidos à anestesia e anestesiados. Foi estabelecido o tempo para o radiofármaco obter acúmulo máximo em cada um dos rins e o tempo para este acúmulo máximo ser reduzido pela metade. Não houve diferença estatística entre os valores dos animais não-anestesiados e anestesiados, nem entre machos e fêmeas, tampouco entre os rins esquerdo e direito. / In internal medicine of domestic cats, imaging modalities, such as ultrasonography, radiography and intravenous pylogram are widely used. Scintigraphy is a non-invasive technique, which provides functional information of each individual kidney; however, it is not widely available or utilized currently in veterinary medicine. The aim of this study was to determine the time of excretion of each kidney in normal domestic cats using nuclear scintigraphy. Fifteen cats (9 males and 6 females) determined to be within normal limits for radiographic and ultrasonographic renal parameters, were divided into two experimental groups (awake and anesthetized cats). Time to maximum radiopharmaceutical activity (T max) and time to decline to half maximum radiopharmaceutical activity (half-time) were determined in each kidney for each cat. No statistical difference was found between groups (awake vs. anesthetized) or sex (males vs. females), or between left and right kidneys.
25

Avaliação da técnica de cintilografia da perfusão pulmonar em cães / Evaluation of pulmonary perfusion scintigraphy technique in dogs

Rodrigues, Gabriela Silva 27 February 2004 (has links)
A avaliação da técnica de cintilografia da perfusão pulmonar foi realizada em 10 cães machos, da raça Rottweiler, radiograficamente normais e soronegativos para dirofilariose, utilizando-se o macroagregado de albumina sérica humana marcado com tecnécio-99m ([99mTc](MAA)) como radiofármaco. Cada animal sedado foi submetido a três diferentes tratamentos, com administração de 50.000, 100.000 e 300.000 partículas de MAA. As imagens obtidas com as doses variadas do radiofármaco, foram comparadas de forma qualitativa e quantitativa, incluindo nesta última a avaliação do índice de perfusão pulmonar e homogeneidade das imagens. Não foram observadas diferenças significativas entre as imagens durante a avaliação visual e cálculo da quantificação relativa da perfusão pulmonar. Porém, o cálculo da uniformidade integral demonstrou diferença significativa na homogeneidade da imagem pulmonar entre as diferentes doses de MAA. Pode-se concluir que existe um aumento na homogeneidade da imagem diretamente relacionado ao número de partículas de magroagregado de albumina injetado, ainda que tal diferença não tenha sido percebida pela análise qualitativa. / The evaluation of pulmonary perfusion scintigraphy technique was accomplished in 10 Rottweiler male dogs, with normal thoracic radiographs and negative for Dirofilaria immitis, using macroaggregated human serum albumin tagged with technetium-99m ([99mTc](MAA)) as radiopharmaceutical. Each sedated animal was subimited to 3 different treatments, with administration of 50.000, 100.000 and 300.000 particles of MAA. The obtained images with diverse radiopharmaceutical doses were qualitative and quantitative compared, including in this the evaluation of radiopharmaceutical distribution and the homogeneity index. There were observed no significative differences between the images during the visual evaluation and calculation of the relative quantification of the lung perfusion. However, the integral uniformity calculation demonstrated significative difference at the homogeneity of the lung image between the different MAA doses. That leads to the conclusion that there is an increase at the images homogeneity directly related to the number of albumin macroaggregated particles injected, though difference has not been realized by the qualitative analysis.
26

Conocimiento del paciente respecto a las indicaciones de adquisición PET/CT y su relación con el corregistro de imágenes. Hospital Nacional Guillermo Almenara Irigoyen, 2018

Dominguez Veramendi, Wendy Vanessa January 2018 (has links)
Determina la relación entre el conocimiento del paciente respecto a las indicaciones de adquisición PET/CT con el corregistro de imágenes en el Hospital Nacional Guillermo Almenara Irigoyen, durante enero a febrero del 2018. El estudio es de enfoque cuantitativo, tipo observacional, transversal y prospectivo, con diseño correlacional, que tuvo como muestra a 92 pacientes a quienes se les realizó PET/CT con 18F-FDG en el servicio de Medicina Nuclear. Para el análisis descriptivo de variables categóricas, se emplearon frecuencias absolutas y porcentuales y para variables continuas, se utilizaron promedios y desviación estándar. Se utilizó la prueba U de Mann Whitney para relacionar las variables de estudio, donde un valor de p menor a 0.05 demostró una diferencia estadísticamente significativa. El conocimiento respecto a las indicaciones de adquisición PET/TC alcanzó un promedio de 9.32. En los corregistros de imágenes en estudios PET/TC, el 94.6% es buena y el 5.4% es regular. La calidad de imagen TC en el 95.7% de los estudios es buena y en el 4.3% es regular, mientras que la calidad de imagen PET en el 97.8% de los estudios es buena y en el 2.2% mala. Se halló una relación significativa entre la calidad de la imagen TC y el conocimientos (p=0.026). Asimismo, hubo una relación significativa entre el conocimiento y la calidad de imagen PET (p=0.039). Sin embargo, a nivel general no se encontró relación significativa entre el corregistro de la imagen PET/TC y el conocimiento (p=0.129). La conclusión es que no existe una relación significativa entre el corregistro de la imagen y el conocimiento (p=0.129). / Tesis
27

Grado de cumplimiento de los criterios de calidad en exámenes de tomografía computada de cerebro. Hospital Nacional Edgardo Rebagliati Martins. Julio – agosto, Lima 2018

Montoya Miranda, Jonathan Kitim January 2019 (has links)
Evalúa el grado de cumplimiento de los criterios de calidad en examen de tomografía computada de cerebro en el Hospital Nacional Edgardo Rebagliati Martins durante el periodo de julio a agosto 2018. Realiza un enfoque cuantitativo, observacional, retrospectivo y de corte transversal, con diseño descriptivo. La muestra estuvo conformada por 151 exámenes tomográficos de cerebro, realizados en el Hospital Nacional Edgardo Rebagliati Martins durante los meses julio y agosto del 2018. El análisis estadístico se realizó mediante frecuencias relativas (porcentajes). Encuentra que la visualización de los exámenes de tomografía computada en su mayoría fue de alta (75.5%) y media (22.5%) calidad, visualizándose al 100% los vasos tras la administración de contraste. La reproducción crítica de los exámenes de tomografía computada en su mayoría fue de alta (68.9%) y media (25.2%) calidad, evaluándose al 100% la reproducción visualmente nítida del espacio de líquido cefalorraquídeo alrededor del mesencéfalo, reproducción visualmente nítida del espacio de líquido cefalorraquídeo sobre el cerebro y reproducción visualmente nítida de los grandes vasos y plexos coroideos tras contraste. El cumplimiento de los criterios de calidad en examen de tomografía computada de cerebro se encontró que gran parte fue alto (58.9%) y medio (34.4%). Concluye que el grado de cumplimiento de los criterios de calidad en examen de tomografía computada de cerebro en el Hospital Nacional Edgardo Rebagliati Martins durante el periodo de julio a agosto 2018 fueron de alto (58.9%) a medio (34.4%). / Tesis
28

Estudo comparativo entre metodologias de cromatografia planar para controle radioquímico de radiofármacos de Tecnécio-99m / Comparison study among methodologies of planar chromatography for radiochemical control of Tecnécio-99m radiopharmaceuticals

Elisiane de Godoy Monteiro 26 April 2012 (has links)
Os radiofármacos são substâncias que possuem radioisótopos em sua composição. Cerca de 95% dos procedimentos realizados em medicina nuclear faz o uso de radiofármacos com finalidade diagnóstica, sendo os reagentes liofilizados (RL) marcados com Tecnécio-99 meta estável (99mTc), obtido a partir de um gerador de 99Mo/99mTc, os mais utilizados. O controle de qualidade representa o conjunto de ensaios a serem realizados para certificar que o produto é adequado ao propósito. Um aspecto importante a ser avaliado nos radiofármacos de 99mTc é a pureza radioquímica (% PRq) para quantificação de pertecnetato livre (99mTcO4 -) e tecnécio coloidal (99mTcO2), principalmente por cromatografia em papel (CP), em camada delgada (CCD) e cromatografia líquida de alta eficiência (CLAE). O objetivo deste trabalho foi realizar a comparação das metodologias de controle radioquímico de RL marcados com 99mTc descritas nas farmacopéias americana (FA) e europeia (FE) com aquelas utilizadas no IPEN. O eluído de 99mTcO4 e os RL: DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH e Sn Coloidal foram provenientes do IPEN-CNEN/SP. Foram utilizados os suportes cromatográficos TLC-celulose, TLC-SG,TLC-SG fase reversa, HPTLC-celulose e HPTLC-SG da Merck e ITLC-SG da Pall Corporation, W1MM, W3MM, W17M e W31ET da Whatman. A contagem da radioatividade foi feita em contador gama Perkin Elmer modelo Cobra D-5002. A marcação dos RL foi feita de modo a obter concentração radioativa de 55,0 MBq mL-1 (1,5 mCi mL-1). Foram determinadas as %99mTcO4 -, %99mTcO2 e % PRq até 4 horas de marcação. Dos 11 RL, apenas EC e GHA não possuem método de controle radioquímico na FA e FE. Na FA e/ou na FE, os métodos para DTPA, MDP, PIRO, SAH e Sn Coloidal utilizam ITLC-SG; no IPEN, este suporte cromatográfico é utilizado em DISIDA, EC, ECD, GHA, PIRO, MIBI e SAH. Devido à descontinuidade na fabricação de ITLC-SG (recomendado em 40, 70 e 41% das metodologias da FA, FE e IPEN, respectivamente), foi necessário buscar alternativas para sua substituição no controle radioquímico, avaliando-se suportes do tipo HPTLC (celulose e sílica gel) e Whatman (com diferenças de espessura e fluxo de corrida). Os resultados de % PRq determinada pelos métodos descritos na FA, FE, IPEN e os demais sistemas avaliados que apresentaram coeficiente de variação menor que 5% não foi considerada diferença significativa entre os métodos. Os sistemas cromatográficos avaliados neste trabalho podem ser utilizados em substituição ao suporte ITLC-SG. O HPTLC-celulose foi o suporte que apresentou tempo de análise, perfil cromatográfico e custo semelhante ao ITLC-SG, tornando-o um dos suportes mais indicados a ser utilizado como alternativa ao ITLC-SG nos 11 RL avaliados. / Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic pruposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m (99mTc), obtained from 99Mo/99mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in 99mTc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate (99mTcO4 -) and technetium colloidal (99mTcO2) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perfom the comparison among the radiochemical control methodologies of LR labeled with 99mTc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. 99mTcO4 - eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-celulose, TLC-SG,TLC-SG reverse phase, HPTLC-celulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL-1 (1,5 mCi mL-1) of final radioactive concentration. The %99mTcO4 -, %99mTcO2 and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was necessary to search alternatives to replace ITLC-SG plate in the radiochemical control, comparing with HPTLC (cellulose and silica gel) and Whatman plates (with thickness and flow rate differences). The % RqP results determined by the methods described in USP, EP, IPEN and the methods evaluated in this work presented coefficient of variation less than 5%, and it was not considered a significant value among the methods. Some chromatographic systems evaluated in this work can be used as replacement to the ITLC-SG plate. HPTLC-cellulose was the plate that presented time of analysis chromatography profile and cost similar to ITLC-SG, making it one of the most indicated to replace ITLC-SG, in 11 LR evaluated.
29

Avaliação cintigráfica da resposta terapêutica de tumores pulmonares não operáveis

Cunha, Lídia Alexandra dos Santos January 2006 (has links)
Tese de mestrado. Engenharia Biomédica (Área de especialização em Análise e Processamento de Sinal e Imagem). 2006. Faculdade de Engenharia. Universidade do Porto, Faculdade de Medicina da Universidae de Coimbra, Universidade de Aveiro
30

Desempeño de los docentes de Maestría en Enfermería y su relación con el nivel de satisfacción de los maestrandos de Enfermería en la UNMSM, Lima - 2017

Reyes Pariona, Lucio Similiano January 2019 (has links)
Determina la relación entre el desempeño de los docentes de maestría en enfermería con el nivel de satisfacción de los maestrandos de enfermería en la Universidad Nacional Mayor de San Marcos, Lima-2017. El estudio es de tipo cuantitativo, descriptivocorrelacional, de corte transversal. La población estuvo constituida por 30 maestrandos de enfermería de la U.N.M.S.M, los datos fueron recolectados haciendo uso de 2 escalas tipo Likert modificadas, los cuales fueron sometidos a pruebas de validez y confiabilidad respectiva. Los participantes se caracterizaron por tener entre 31 y 35 años (40%), de sexo femenino (83,3%) y ser solteros (70%). Respecto a desempeño docente predominó el nivel regular (60%) y nivel medio de satisfacción (53,3%). Se encontró correlación positiva media de 0,62 entre las variables (p <0,05). Al correlacionar cada dimensión con el nivel de satisfacción: capacidades pedagógicas se encontró correlación moderada de 0,57 y un valor p=0,001<0,05; disposición para labor docente, correlación moderada de 0,524 y un valor p=0,003<0,05; responsabilidad laboral, correlación moderada de 0,495 y un valor p=0,005 <0,05. Se concluye que parece ser que el desempeño de los docentes de maestría en enfermería se relaciona significativamente con el nivel de satisfacción de los maestrandos, por lo que es sugerente tomar en cuenta los resultados con el fin de elevar la calidad educativa en este nivel de estudio. / Tesis

Page generated in 0.0448 seconds