• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • 92
  • 3
  • 1
  • Tagged with
  • 233
  • 233
  • 94
  • 82
  • 81
  • 79
  • 41
  • 36
  • 25
  • 22
  • 19
  • 17
  • 16
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Etilenodicisteína-99m Tc é um radiofármaco mais efetivo que o ácido dietilenotriaminopentacético-99m Tc para excluir obstrução em pacientes com dilatação das vias urinárias / Technetium-99m-L,L-Ethylenedicysteine is more effective than technetium-99m diethylenetriamine penta-acetic acid for excluding obstruction in patients with pyelocalicinal dilation

Lima, Mariana da Cunha Lopes de 10 May 2010 (has links)
Orientador: Celso Dario Ramos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-16T23:06:04Z (GMT). No. of bitstreams: 1 Lima_MarianadaCunhaLopesde_D.pdf: 5311684 bytes, checksum: 4e6a0ba6a1a013ca5e9a995b127a5a95 (MD5) Previous issue date: 2010 / Resumo: A diferenciação entre obstrução mecânica e dilatação das vias urinárias sem obstrução é extremamente importante para se determinar o tratamento correto. O objetivo deste trabalho foi avaliar a utilidade do estudo renal dinâmico com diurético (ERDD) com L,L-etilenodicisteína marcada com tecnécio-99m (EC-99mTc) em pacientes com resultados indeterminados ou possíveis falso-positivos para obstrução no ERDD com ácido dietilenotriaminopentacético marcado com 99mTc (DTPA-99mTc). Noventa e dois pacientes foram estudados, sendo 63 do sexo masculino e 29 do sexo feminino, com idades variando de um mês a 74 anos (média 16,6 +/-21,25 anos), num total de 103 rins com padrão cintilográfico indeterminado (20/103) ou possível resultado falso positivo para obstrução atribuível à função glomerular reduzida ou dilatação acentuada das vias excretoras (83/103) no ERDD com DTPA-99mTc (<60% de excreção do radiofármaco em 20 minutos - tempo em que 50% do radiofármaco foi excretado pelos rins (T½) >15 minutos). Os pacientes foram então submetidos a ERDD com EC-99mTc, sendo realizadas imagens dinâmicas antes e após a administração venosa de furosemida e seguindo-se o mesmo protocolo de aquisição de imagens utilizado com DTPA-99mTc. O intervalo de tempo entre os ERDD com DTPA-99mTc e com EC-99mTc variou de 2 a 64 dias. As taxas de excreção aos 20 minutos após a injeção de furosemida foram calculadas para ambos radiofármacos e foram estatisticamente comparadas utilizando-se o teste t pareado. A porcentagem de excreção após a administração de furosemida foi de 25,3% +/- 18,2% para DTPA-99mTc e de 41,2 +/- 26,1% para EC-99mTc (p<0,0001). Utilizando-se EC-99mTc, obstrução foi excluída em 36 de 103 rins, com excreção >60%. Dez dos 83 rins (12,0%) que apresentavam padrão obstrutivo ao DTPA-99mTc revelaram-se indeterminados no ERDD com EC-99mTc. Houve concordância nos resultados do ERDD com EC-99mTc e com DTPA-99mTc em 54/83 rins com padrão obstrutivo (65,1%) e em 3/20 rins com padrão indeterminado (15,0%). O estudo com EC-99mTc é mais efetivo que o com DTPA-99mTc na exclusão de obstrução das vias urinárias, apresentando menos resultados falso-positivos e indeterminados. O radiofármaco EC-99mTc pode substituir o DTPA-99mTc na avaliação de pacientes com dilatação do trato urinário / Abstract: The differentiation between mechanic obstruction and dilation without obstruction is critical to determine the correct treatment approach. The aim of this study was to evaluate the utility of diuretic dynamic renal scintigraphy (DDRS) with 99mTc-EC in patients with indeterminate or possible false-positive results for urinary obstruction by 99mTc-DTPA DDRS. A total of ninety-two patients (63 male; mean age 16.6 ± 21.25 years) were studied, with a total of 103 kidneys presenting indeterminate (20/103) or possible false-positive results for obstruction attributable to reduced renal function or severe kidney dilation (83/103) by 99mTc-DTPA DDRS (<60% of radiopharmaceutical excreted in 20 minutes - half-time clearance (T½) >15 minutes). Patients were reimaged after intravenous injection of 99mTc-EC, with dynamic images before and after furosemide administration using the same acquisition parameters applied in the previous 99mTc-DTPA study. Time interval between 99mTc-DTPA and 99mTc-EC renograms was 2 to 64 days. The percentage of excreted material 20 minutes after furosemide was calculated using both radiopharmaceuticals, and were statistically compared using the paired samples t test. The excretion after furosemide injection was 25.3%±18.2% for 99mTc-DTPA and 41.2±26.1% for 99mTc-EC, with a statistically significant difference between both radiopharmaceuticals (p<0.0001). Using 99mTc-EC obstruction was excluded in 36 of 103 kidneys, which excreted > 60%. A total of 10 of 83 kidneys (12.0%) with an obstructive pattern by 99mTc-DTPA study turned out to be indeterminate by 99mTc-EC DDRS. There was an agreement between 99mTc-EC and 99mTc-DTPA studies in 54 of 83 kidneys with obstructive (65.1%) and in 3 of 20 (15.0%) with indeterminate patterns. 99mTc-EC is more effective than 99mTc-DTPA for excluding obstruction, presenting less false-positive and indeterminate results. 99mTc-EC can substitute 99mTc-DTPA to evaluate patients with urinary tract dilation / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências
42

Metodo simplificado para estimativa da função renal absoluta com DMSA-99m Tc : comparação direta com a radioatividade medida em peças de nefrectomia

Lima, Mariana da Cunha Lopes de 31 August 2005 (has links)
Orientadores: Ubirajara Ferreira, Celso Dario Ramos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-05T22:49:34Z (GMT). No. of bitstreams: 1 Lima_MarianadaCunhaLopesde_M.pdf: 913938 bytes, checksum: 416039055b58df18b23ec94d21f82bce (MD5) Previous issue date: 2005 / Resumo: Os estudos de Medicina Nuclear são os métodos de imagem mais adequados para se estimar a função renal e adicionam informações funcionais aos estudos anatômicos, como a ultra-sonografia e os métodos radiológicos. O DMSA-99mTc é o radiofármaco de escolha para imagens de alta resolução do córtex renal, permitindo, também, estimar a massa de parênquima renal funcionante. Os exames atuais medem a função relativa entre os rins, independentemente do nível de creatinina.Diferentes técnicas para se medir a função renal absoluta (FRA), ou seja, isolada de cada rim, com DMSA-99mTc têm sido descritas utilizando imagens planas e a tomografia computadorizada por emissão de fótons únicos (SPECT). Entretanto, essas técnicas são de difícil execução e implantação na rotina diária. O objetivo deste trabalho foi testar um método mais simples para se determinar a FRA com DMSA-99mTc antes de nefrectomias e validá-lo utilizando-se as contagens radioativas das próprias peças de nefrectomia como referência. Foram estudados dezessete pacientes (12 pacientes do sexo feminino e cinco do sexo masculino), com idades variando de 22 a 82 anos (média 50,8 anos), selecionados para a realização de nefrectomia por diferentes indicações. A cintilografia renal foi realizada três a quatro horas após a administração venosa de 185 MBq (05 mCi) de DMSA-99mTc. A captação renal de DMSA-99mTc foi determinada utilizando-se os seguintes parâmetros: a radioatividade da seringa (medida com um calibrador de dose); a imagem da seringa antes da injeção; a imagem do rim três a quatro horas após a injeção do radiofármaco (imagem in vivo); a imagem da peça de nefrectomia (imagem ex vivo), que não sofre atenuação dos tecidos extra-renais. O valor de referência para a captação de DMSA-99mTc no rim operado foi considerado como aquele determinado medindo-se a radioatividade diretamente na própria peça de nefrectomia utilizando o mesmo calibrador de dose usado para medir a dose de DMSA-99mTc injetada no paciente antes da cirurgia. As FRA foram calculadas utilizando as imagens in vivo e ex vivo dos rins. Esses valores foram comparados com os valores de referência (captação de DMSA-99mTc) através de análise de regressão linear. A média das FRA obtidas com as imagens in vivo e ex vivo e com o método de referência foram, respectivamente, 5,6%, 6,4% e 6,8%. Os valores de FRA foram muito semelhantes àqueles obtidos com o método de referência, conforme foi demonstrado pela análise de regressão linear, que revelou r-quadrado de 0,96 (imagem in vivo e método de referência) e 0,99 (imagem ex vivo e método de referência). O método cintilográfico testado para se determinar a função renal absoluta com DMSA-99mTc é simples e aplicável ao uso rotineiro. Esse método apresenta excelente correlação com a medida direta da radioatividade em peças de nefrectomia / Abstract: The studies with radionuclides in Nuclear Medicine are the most adequate imaging methods to estimate the renal function, adding functional information to the anatomic studies, such as ultrasound and X-ray methods. 99mTc-DMSA is the radiopharmaceutical of choice for high-resolution imaging of the renal cortex and estimating the functional renal mass. The present studies with DMSA-99mTc measure the relative tubular function, independently of the creatinine levels. Different techniques to measure the absolute uptake of 99mTc-DMSA by the kidneys, that is the quantification of isolated renal 99mTc -DMSA uptake, have been described using planar and single photon emission tomography (SPECT), but the methods remain quite complicated and not feasible for the routine use. The aim of this study was to test a simplified method to determine absolute renal function (ARF) with 99mTc-DMSA before nephrectomies, using the radioactive counts of nephrectomy specimens as reference. A total of 17 patients were studied, 12 female and five male, 22 to 82 years old (mean 50.8). All patients had been selected for nephrectomy due to different indications. The renal scintigraphy was performed 3 to 4 hours after the intravenous administration of 185 MBq (05 mCi) of 99mTc-DMSA. The in vivo renal uptake of 99mTc-DMSA was determined using the radioactivity of the syringe before the injection (measured with a dose calibrator); the image of the syringe before injection; the image of the kidney, obtained three to four hours after the radiopharmaceutical administration (in vivo image) and the image of the nephrectomy specimen (ex vivo image), which does not have the tissue atenuation. The reference value for renal uptake of 99mTc-DMSA was determined by measuring the radioactivity of the nephrectomy specimen with the same dose calibrator. The ARF values were calculated using the in vivo and ex vivo images. These values were compared to the reference values (99mTc-DMSA uptake) applying linear regression. The mean ARF values obtained with the images in vivo and ex vivo and with the reference method were, respectively, 5.6%, 6.4% and 6.8%. The ARF values were very similar to those obtained with the reference method, as shown by the linear regression analysis, revealing an r-square of 0.96 (in vivo image and the reference method) and 0.99 (ex vivo image and reference method). The attenuation correction method used over the in vivo images of the kidneys was found to be efficient, since the values obtained with the in vivo and ex vivo images were very similar, with linear regression analysis revealing an r-square of 0.95. The proposed method to determine the absolute renal function with 99mTc-DMSA is simple and feasible for routine clinical use. This method demonstrates excellent correlation with the direct measurement of the radioactive counts of nephrectomy specimens / Mestrado / Pesquisa Experimental / Mestre em Cirurgia
43

Avaliação da compressão com perdas em imagens cardiacas de medicina nuclear

Monteiro, Hamilton 03 September 1996 (has links)
Orientador: Lincoln Assis Moura Jr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e Computação / Made available in DSpace on 2018-07-21T19:29:53Z (GMT). No. of bitstreams: 1 Monteiro_Hamilton_M.pdf: 9165260 bytes, checksum: 39ae4d32fb2d82b25c67aff6bba80ce8 (MD5) Previous issue date: 1996 / Resumo: As técnicas de compressão de imagens tem como objetivo reduzir o volume de dados a serem armazenados ou transmitidos em sistemas digitais. A utilização de técnicas de compressão com perdas merece ser investigada, uma vez que as mesmas apresentam altas taxas de compressão, ainda que alterando o conteúdo de informação das imagens. Este trabalho estuda o efeito de aplicação da compressão com perdas em imagens cardíacas de medicina nuclear e a avalia a possibilidade de utilização dessas imagens no diagnóstico clínico. Foram estudadas 120 imagens, de pacientes normais e portadores de patologias cardíacas, que foram comprimidas/descomprimidas pela técnica da transformada discreta do cosseno (DCT). A taxa de compressão média foi da ordem de 11:1. Os efeitos da técnica de compressão no cômputo de parâmetros qualitativos e quantitativos dessa modalidade diagnóstica foram submetidos a análise estatística. Adicionalmente, os parâmetros qualitativos de interesse clínico foram analisados por dois especialistas médicos com experiência na observação desse tipo de estudo. Os resultados mostram que a compressão utilizada é adequada para análise visual e para a extração de parâmetros que não requeiram grande suavidade temporal. Entretanto, para o cômputo das imagens funcionais de amplitude e fase, a técnica utilizada mostrou-se inadequada, recomendando-se, então, a utilização de tolerâncias menores, e portanto, menores taxas de compressão / Abstract: Image compression techniques have been used as a mean to reducing the amount of data to be stored or transmitted in digital systems. The use of lossy image compression techniques is worth investigation, since those techniques lead to high compression rates, though they modify the information content of original images. In this work, we assess the effect of applying a lossy image compression technique to nuclear medicine images of the heart and evaluate the suitability of using compressed images for diagnosis. A set of 120 blood pool images from normal and abnormal patients was submitted to compression and decompression using the Discrete Cosine Transform (DCT). The average compression rate was 11:1. The effects of DCT compression on the estimation of qualitative and quantitative clinical parameters was submitted to statistical analysis. Additional/y, clinical parameters of subjective analysis were assessed by two skilled clinicians. Results show that DCT compression is suitable for visual analysis and for extracting parameters which do not require great accuracy as far as the time axis is concemed. For computing functional images (amplitude and phase) DCT seems to be unsuitable, at least for the thresholds used in this work. Therefore, it is recommended that lower thresholds (and thus lower compression rates) be used if functional images are to be computed. / Mestrado / Mestre em Engenharia Elétrica
44

Otimização dos parametros do filtro butterworth na reconstrução tomografica em spect cardiaco

Abe, Rubens 07 February 1999 (has links)
Orientador: Sergio Shiguemi Furuie / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T10:56:09Z (GMT). No. of bitstreams: 1 Abe_Rubens_M.pdf: 4427357 bytes, checksum: a5397256321b22e23ac4dfb44486ee83 (MD5) Previous issue date: 1999 / Resumo: Têm sido formulados vários filtros digitais que levam em consideração a natureza estatística do ruído para a melhoria da qualidade final das imagens de SPECT (tomografia por emissão de fóton único). Este trabalho avalia a estimativa das projeções (filtro de Maeda), que leva em consideração o modelo de ruído de Poisson e melhora a qualidade das reconstruções torno gráficas com baixa relação sinal-ruído, que é o caso de imagens de SPECT. Diversos artigos sobre processamento de imagens de medicina nuclear afirmam que o ruído nas imagens segue a distribuição de Poisson. Portanto, é muito importante conhecer a característica do ruído em toda faixa de contagem nas projeções (com e sem correção de atenuação) de SPECT utilizadas em imagens clínicas, para aplicar eficientemente a estimativa das projeções. Na primeira parte deste trabalho foi feito um estudo da caracterização do ruído, usando imagens reais obtidas de "phantom"(simulador) cilíndrico. A análise estatística das contagens utilizando o "Goodness of Fit Test" mostrou os seguintes resultados: 1) A distribuição de ruído é de Poisson na faixa de 20 a 150 contagens/pixel e não é Poisson mas Gaussiana na faixa de 200 a 400 nas projeções sem pré-processamento; 2) As projeções com correção de atenuação não têm distribuição de Poisson em nenhum nível de contagem, mas é Gaussiana na faixa de 200 a 400. Corno nas projeções de SPECT clínico as contagens/pixel são < 150, conclui-se que se pode utilizar a estimativa das projeções ou outro filtro que considere o ruído com distribuição de Poisson. Para contagens entre 200 e 400 deve-se empregar um filtro que considere a distribuição Gaussiana, e para as projeções com correção de atenuação e contagens inferiores a 150 não se deve aplicar filtros do tipo Poisson ou Gaussiana. A segunda parte deste trabalho consiste em otimizar o SPECT cardíaco aplicando a estimativa das projeções em "phantoms" sintéticos. Na maioria dos sistemas comerciais de SPECT, utiliza-se para reconstrução torno gráfica, a Retroprojeção Filtrada com filtro Butterworth. Este filtro possui dois parâmetros livres que são usados nos exames clínicos sem otimização, fazendo-se urna comparação visual das imagens reconstruídas com diferentes parâmetros e escolhidas qualitativamente. Os parâmetros do filtro Butterworth foram otimizados para retroprojeção filtrada com e sem estimativa das projeções". para detectabilidade de infartos (menor concentração radioativa no miocárdio) ou áreas frias, através da determinação do valor máximo da figura de mérito de detectabilidade de áreas frias. Também foi avaliado o comportamento das figuras de mérito de precisão estrutural e detectabilidade de áreas quentes (maior concentração) em função dos parâmetros do filtro. Os resultados obtidos foram: Com estimativa das projeções: freqüência de corte =0,25 Nyquist e ordem =7. 2) Somente com filtro Butterworth : freqüência de corte =0,25 Nyquist e ordem =7. Nota-se que os parâmetros otimizados para as reconstruções foram os mesmos, com e sem estimativa das projeções. As figuras de mérito de detectabilidade de áreas frias e quentes para reconstruções com estimativa das projeções variam pouco com a ordem e a freqüência de corte. Conclui-se que a utilização da estimativa das projeções nas reconstruções de SPECT melhora significativamente (p<0,005) a precisão estrutural sem resultar em melhoria na detectabilidade de áreas frias e quentes, e traz a vantagem adicional de se obter imagens torno gráficas que não dependam tanto do filtro de reconstrução / Abstract: Several digital filters that take into account the statistical nature of the noise have been formulated for the improvement of the final quality of SPECT images (Single Photon Emission Tomography). This work evaluates the projection estimation (Maeda filter), that takes in consideration the Poisson noise mode! and improves the quality of the tomographic reconstructions with low signal-noise ratio, which is the case of SPECT images. Several articles on processing of nuclear medicine images state that this type of noise follows the Poisson distribution. Therefore, it is very important to know the characteristics of the noise in all count range in SPECT projections (with and without attenuation correction) considered in the clinical images, in order to use efficiently the projection estimation. In the first part of this work, a study ofthe noise characterization was carried out, using real images obtaÜ1ed from a cylindrical phantom. The statistical analysis of the measured counts using Goodness of Fit Test showed the following results: 1) The noise distribution is Poisson in the range from 20 to 150 counts/pixel and it is not Poisson but Gaussian in the range from 200 to 400 in projections without any pre-processing; 2) The projections with attenuation correction do not have Poisson distribution m any count level, but it is Gaussian in the range from 200 to 400. Since m clinical SPECT projections the counts/pixel is < 150, the projection estimation or other filter that considers the Poisson distribution noise can be used. For counts between 200 and 400 a filter that considers the Gaussian distribution should be used, and for projections with attenuation correction and counts < 150 we should not apply Poisson or Gaussian type filters . The second part of this work consists in optimizing the cardiac SPECT using the projection estimation in synthetic phantoms. In most of the commercial SPECT systems, Filtered Backprojection with Butterworth filter is used for tomographic reconstruction. This filter has two free parameters that are used in the clinical exams without otimization, one makes a visual comparison of the reconstructed images with different parameters and these are qualitatively chosen. The Butterworth filter parameters were optimized for both the cases, with and without projection estimation, for infarcts or cold areas detectability (smaller concentration of radioactivity in myocardium), through the maximum value of the figure of merit determination for cold spot detectability. The behaviour ofthe figure of merit for structural precision and hot spot detectability (larger concentration) were also evaluated as function ofthe filter parameters. The obtaÜ1ed results were: 1) With projections estimation: cut off frequency =0.25 Nyquist and order =7. 2) With only Butterworth filter : cut off frequency =0.25 Nyquist and order =7. It is noticed that the optimized parameters for the reconstructions were the same, with and without the projection estimation. For reconstruction with projection estimation the figures of merit for cold and hot spots detectability vary little with order and cut off frequency. In conclusion, the use of the projection estimation in SPECT reconstruction improves signifieant1y (p<0.005) the structural precision without resulting in improvement m detectability of cold and hot spots and brings the additional advantage of obtaining tomographic images that are less sensitive to the reconstruction filter / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
45

Avaliação dos efeitos do extrato etanolico de Curatella americana sobre a marcação de elementos sanguineos com tecnecio 99M e na sobrevivencia de cultura bacteriana

Soares, Fernanda Rocha 11 May 2003 (has links)
Orientador: Alba Regina Monteiro Souza Brito / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T18:03:14Z (GMT). No. of bitstreams: 1 Soares_FernandaRocha_M.pdf: 2760992 bytes, checksum: 81b801ed89addd94c2be028c3be98e11 (MD5) Previous issue date: 2003 / Resumo: O tecnécio 99-m (Tc-99m), na forma de pertecnetato de sódio (Na99"'Tc04), é um radiofármaco empregado em avaliações clínicas da medicina nuclear. A Curatella americana é uma planta de cerrado cuja parte utilizada é a casca do caule com uso antiulcerogênico. Tem sido descrito que a interação de drogas altera a biodistribuição dos radiofármacos, bem como sua ligação aos elementos sangüíneos ou a outras moléculas, o que pode alterar diagnósticos usando radiofármacos. Portanto, para contribuir com o estudo de como outras substâncias podem interferir na marcação do Tc-99m e também com a finalidade de elucidar efeitos biológicos in vitro, foram estudados os efeitos da C. americana sobre a marcação de elementos sangüíneos. Os resultados obtidos in vitro mostram que houve diminuição significativa (p< 0,001) na porcentagem de fixação do Tc 99m em hemácias entre o grupo controle (97,0 f: 2,00) e os grupos tratados com C. americana 100%; 50%; 25%; 12,5%,6,2%,3,1%,1,6%,0,8% (49,3:t 6,7; 48,9:t 5,2; 44,2 f: 9,9; 48,1 f: 4,7; 35,3 f: 7,1; 37,3 f: 10,2; 34,1 f: 3,8; 41,2 f: 2,1; respectivamente), onde 100% corresponde à concentração máxima utilizada do extrato vegetal, ou seja, 5 mg/mL; 50%; 25%; 12,5%, 6,2%, 3,1%, 1,6%, 0,8% correspondem às diluições 1: 1 subseqüentes do grupo 100%. Na fixação do Tc-99m em proteínas celulares foi possível observar, também, redução da fixação do grupo controle (79,6 t 2,9) em relação aos seguintes grupos tratados 100%; 50%; 25%; 12,5%,6,2%, 3,1% (41,5 :t 8,8; 39,6 :t 16,6; 44,1 t 12,1; 43,9 :t: 12,7; 42,7 :t 8,7; 44,5 :t: 1,7; respectivamente). C. americana não alterou significativamente a marcação das proteínas plasmáticas com Tc-99m. Em animais tratados com doses de 250 mg/Kg, via oral, por cinco dias consecutivos com extrato de C. americana constatou-se que a porcentagem de captação de Tc-99m aumentou significativavemnte nos pulmões (de 0,3 :t: 0,07 para 0,5 :t: 0,2), duodeno (de 0,3 :t 0,2 para ,5 :t: 0,1) e músculo (de 0,09 t 0,02 para0,1+-0,04)controle e tratado, respectivamente (p< 0,05), e no pâncreas (de 0,1 :t 0,03 para 0,3 :t 0,07) controle e tratado, respectivamente (p< 0,01). Também foram observadas alterações morfológicas nas hemácias tratadas in vitro com o extrato, mesmo em baixas concentrações, alterando a forma da hemácia e, portanto, diminuindo significativamente a relação perímetro/área de 0,9 :t 0,2 (controle) para 0,7 :t 0,03; 0,7 :t 0,05; 0,7 :t 0,02; 0,6 :t 0,05; 0,7 :t 0,03 (6,2%; 12,5%; 25%, 50%, 100%, respectivamente); estes resultados poderiam justificar a redução da fixação do Tc-99m nas hemácias. Também foi estudado o efeito da incubação do extrato com culturas de Escherichia coli AS 1157 houve ainda diminuição na taxa de sobrevivência de Escherichia coli indicando uma citotoxicidade relativamente baixa do extrato, tendo em vista que as quedas mais significativas ocorreram somente nas maiores concentrações utilizadas do extrato de C. americana e após terem sido decorridas cerca de 20 minutos do início do cultivo do microorganismo / Abstract: Technetium 99m (Tc-99m), as sodium pertechnetate (Na99m,-c04), is a radionuclide employed in nuclear medicine clinical evaluations. Curatella americana is a plant from the Brazilian "cerrado" and its bark is used as antiulcerogenic. It has been described that the interaction of drugs alters the biodistribution of radionuclides, as well as its binding to blood elements or to other molecules, what may alter an examination. 50, to contribute with this study, we have studied how other substances interfere on the labeling of Tc-99m and also to elucidate the biological effects in vitro the interference of C. americana in this process was studied too. The results obtained through the in vitro labeling of blood elements showed that there was a significant decrease (p< 0,001) in the fixation of Tc-99m in red blood cells between the control group (97.0 :t 2.0) and the treated groups 100%; 50%; 25%; 12.5%,6.2%,3.1%,1.6%,0.8% (49.3:t 6,7; 48.9:t 5.2; 44.2:t 9.9; 48.1 :t 4.7; 35.3:t 7.1; 37.3 t 10.2; 34.1 t 3.8; 41.2 t 2.1; respectively), where 100% corresponds to the maximum concentration used equal to 5 mg/mL, and 50%; 25%; 12.5%,6.2%,3.1%,1.6%, 0.8% correspond to 100% subsequent dilutions. Regarding the fixation of Tc-99m in cellular protein, there was, also, a decrease in the control group (79.6 t 2.9) with regard to the following treated groups 100%; 50%; 25%; 12.5%, 6.2%, 3.1 % (41.5 :t 8.8; 39.6 t 16.6; 44.1 t 12.1; 43.9 t 12.7; 42.7 t 8.7; 44.5 :f: 1.7; respectively). No significative alterations were observed on the labeling of plasma proteins with Tc-99m. Among animais treated with the extract it was verified an increase in the bond ot Tc-99m on lungs (from 0.3 t 0.07 to 0.5 t 0.2), duodenum (from 0.3 t 0.2 to 0.5 :t 0.1) and muscle (trom 0.09 t 0.02 to 0.1 :t 0.04) control and treated groups, respectively (p< 0.05); pancreas (from 0.1 :t 0.03 to 0.26 t 0.07) control and treated groups, respectively (p< 0.01). Morphological alterations were observed in red blood cells treated in vitro with the extract even under low concentrations, altering the shape of red blood cells significantly and so that, decreasing the perimeter/area relation from 0.9 :t 0.2 (control) to 0.7 :t 0.03; 0.7 :t 0.05; 0.7 :t 0.02; 0.6:t 0.05; 0.7 :t 0.03 (6.2%; 12.5%; 25%, 50%, 100%, respectively). These results could explain the decrease in the fixation of Tc-99m on red blood cells. After the incubation of the extract with cultures of Escherichia coli AS 1157 there was a decrease in thesurvival fraction of this microorganism. This decrease indicated a relatively low citotoxicity of the extract considering that the most significant drop occurred due to the time and concentration of the extract / Mestrado / Mestre em Farmacologia
46

Avaliações dosimétricas em pacientes submetidos à radioiodoterapia com base em fantomas de Voxels e em imagens de medicina nuclear

de Jesus Lopes Filho, Ferdinand January 2007 (has links)
Made available in DSpace on 2014-06-12T23:13:24Z (GMT). No. of bitstreams: 2 arquivo2638_1.pdf: 2679589 bytes, checksum: 974e8cefad2d337fc1433833c1971a27 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / Em radioiodoterapia, os pacientes são submetidos à incorporação da substância radioativa Iodeto de Sódio (NaI), que reage fisiologicamente com metástases, restos de tecido tireoideano e outros órgãos e tecidos do corpo humano. Uma questão complexa é a estimativa da distribuição temporal e espacial da dose absorvida em órgãos e tecidos radiossensíveis dos pacientes submetidos a este tipo de tratamento. Como é praticamente impossível medir de forma direta a dose absorvida em regiões internas do paciente, utiliza-se a dosimetria numérica para tais estimavas. A dosimetria numérica utiliza modelos antropomórficos acoplados a códigos Monte Carlo para simular o transporte da radiação e sua interação com a matéria, bem como avaliar a dose depositada em órgãos e tecidos radiossensíveis. Para realizar estas avaliações de dose é preciso desenvolver algoritmos para simular as fontes radioativas envolvidas no problema. O conjunto formado pelas fontes radioativas, o modelo antropomórfico e o código Monte Carlo é, usualmente, denominado modelo computacional de exposição, onde a palavra exposição está aqui grafada no seu sentido mais geral. A proposta deste trabalho é desenvolver um destes modelos para estimar as frações absorvidas, as frações absorvidas específicas e as razões entre dose equivalente e atividade acumulada do 131I, específico para pacientes submetidos ao tratamento de radioiodoterapia. O modelo antropomórfico usado é o fantoma de voxels FAX (Female Adult VoXel), os algoritmos para simular as fontes radioativas internas são baseados em imagens de varredura de corpo inteiro do paciente e o código Monte Carlo é o EGS4. Os resultados obtidos com o modelo computacional desenvolvido foram comparados com os obtidos com o software MIRDOSE 3 e outros similares publicados. É possível estimar as doses equivalentes nos órgãos e tecidos radiossensíveis dos pacientes usando os coeficientes de conversão aqui desenvolvidos
47

Implantação de um programa de intercomparação de medidas de atividade de radiofármacos utilizados em serviços de medicina nuclear no nordeste

da Conceição de Farias Fragoso, Maria 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:14:23Z (GMT). No. of bitstreams: 2 arquivo2678_1.pdf: 1751073 bytes, checksum: 0c1663cb0478674537f8d157ff6d7415 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os calibradores de radionuclídeos são instrumentos essenciais nos serviços de medicina nuclear (SMN) para a determinação da atividade dos radiofármacos que serão administrados aos pacientes. O desempenho inadequado desses equipamentos leva a doses sub ou superestimadas, comprometendo o sucesso de diagnósticos ou terapias. A intercomparação é uma ferramenta importante para avaliação da qualidade da medição da atividade de radiofármacos nos serviços de medicina nuclear, uma vez que avalia o procedimento de medição como um todo, incluindo o desempenho dos profissionais envolvidos. O propósito deste trabalho é implantar o programa de intercomparação de medidas de atividade de radiofármacos utilizados em SMN localizados na região Nordeste do Brasil, utilizando fontes de 99mTc, 131I, 67Ga, 201Tl e 57Co. Um calibrador de radionuclídeos comercial foi caracterizado como equipamento de referência para este programa. O programa de medidas de atividade foi implantado em serviços de medicina nuclear dos estados de Alagoas, Ceará, Paraíba, Pernambuco, Piauí, Rio Grande do Norte e Sergipe. Verificou-se que 89% dos resultados apresentaram valores dentro dos limites estabelecidos pela CNEN (±10%) e 11% dos resultados foram considerados inaceitáveis decorrentes da utilização de equipamentos baseados em detectores do tipo Geiger-Müller e da falta de treinamento dos operadores. Os serviços cujas medidas se encontraram fora dos limites estabelecidos poderão contar com a colaboração do laboratório de referência, contribuindo com a otimização do procedimento de medição empregado pelo SMN
48

Avaliação da eficácia do avental equivalente a 0,5 mm de chumbo em tomografia por emissão de Pósitrons através de simulações Monte Carlo

FONSÊCA, Rodrigo Bezerra 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:15:49Z (GMT). No. of bitstreams: 2 arquivo8634_1.pdf: 1784772 bytes, checksum: 8fd517fc2d3fb09302f697d0aba20ae8 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Em Tomografia por Emissão de Pósitrons (PET), os profissionais de saúde estão expostos a fótons de 511 keV, resultante do processo de aniquilação pósitron-elétron. Este valor é cerca de quatro vezes superior à energia média dos fótons com 140 keV, normalmente emitida em ambiente envolvendo Tomografia por Emissão de Fóton Único (SPECT). Apesar disso, aventais equivalentes a 0,5 mm de chumbo que já vem sendo utilizados em tarefas envolvendo a SPECT são empregados, também, na PET, independentemente da energia dos fótons emitidos. Neste contexto, este trabalho teve como objetivo avaliar a eficácia dos aventais equivalentes a 0,5 mm de chumbo na radioproteção individual de profissionais envolvidos em procedimentos para exames por PET. Para tanto, a energia média depositada por partícula foi calculada utilizando o método Monte Carlo, com auxílio do código MCNP4C, nas regiões correspondentes às grandezas operacionais Hp(10) e Hp(0,07), em duas situações de exposição individual: com e sem o uso do avental. Os resultados obtidos indicam que na região Hp(10) a dose absorvida com avental é estatisticamente igual a sem o uso do avental. Em relação à região Hp(0,07), o uso do avental acarreta um aumento de até 26% para a dose absorvida. Com base neste trabalho, aventais equivalentes a 0,5 mm de chumbo não oferecem proteção adequada aos profissionais de saúde envolvidos em procedimentos com Tomografia por Emissão de Pósitrons
49

Variabilidad de la biometria del cráneo fetal en el plano transventricular, en comparación al plano transtalamico en pacientes obstétricas de 20 a 30 semanas de gestación en el Policlínico Medical febrero-julio, 2017

Padilla Mimbela, Miguel Enrique January 2017 (has links)
Publicación a texto completo no autorizada por el autor / Determina la variabilidad de la biometría del cráneo fetal en el plano transventricular, en comparación al plano transtalámico en pacientes obstétricas de 20 a 30 semanas de gestación en el policlínico Medical febrero-julio en el año 2017. Desarrolla un estudio de tipo observacional, con diseño analítico comparativo, prospectivo y de corte transversal. Se tomó 62 ecografías obstétricas realizadas a pacientes entre las 20 a 30 semanas de gestación en el periodo de febrero a julio del 2017, donde se obtuvo la imagen del cerebro fetal con las medidas del diámetro biparietal y la circunferencia cefálica en el plano transventricular y transtalámico. Se realizó análisis inferencial con la prueba estadística paramétrica t de student para muestras relacionadas, a un nivel de confianza del 95%. Encuentra que mediante el plano transventricular, el diámetro biparietal tuvo una media de 63.84 mm, y la circunferencia cefálica una media de 228.26 mm. Mediante el plano transtalámico, el diámetro biparietal tuvo una media de 63.49 mm, y la circunferencia cefálica una media de 227.40 mm. Se encontró una diferencia en el diámetro biparietal (p=0.003) y en la circunferencia cefálica (p=0.000), medidas mediante el plano transtalámico y transventricular. No hubo diferencia en la edad gestacional mediante el diámetro biparietal (p=0.568) medidas en el plano transtalámico y transventricular, asimismo, no hubo diferencia en la edad gestacional mediante la circunferencia cefálica (p=0.062) medidas en el plano transtalámico y transventricular. Concluye que existe una mínima variabilidad de la biometría del cráneo fetal en el plano transventricular, en comparación al plano transtalámico. / Tesis
50

Evaluación de la calidad radiográfica torácica en el control del catéter venoso central. Instituto Nacional de Enfermedades Neoplásicas

Blas Garcia, Josue Angello January 2017 (has links)
Evalúa la calidad radiográfica torácica en el control del catéter venoso central de pacientes atendidos en el Instituto Nacional de Enfermedades Neoplásicas. El estudio tiene un enfoque cuantitativo, de tipo observacional, con diseño descriptivo, de corte transversal, retrospectivo. Se trabaja con un total de 100 imágenes radiográficas de pacientes atendidos en el Departamento de Radiodiagnóstico. Para el análisis estadístico se utilizan frecuencias y medidas de tendencia central. La técnica del paciente para la toma radiográfica en el 65% de los pacientes es la anteroposterior y en posición decúbito en el 60%. El posicionamiento final a la toma radiográfica en el 90% es correcta. La valoración de la imagen final en el control del catéter venoso central a la toma radiográfica en el 10% es subexpuesta y en el 89% de las imágenes tienen una calidad respecto a su densidad óptica correcta. El 2% de los catéteres venosos se colocan encima de la Carina, el 20% debajo de la Carina, el 5% tiene una proyección no habitual, el 10% de los catéteres no tienen visibles y en el 63% de los casos la ubicación de la punta del catéter venoso con respecto a la Carina es correcta. El 100% y el 57.1% de los pacientes cuya técnica de posicionamiento es anteroposterior decúbito la ubicación del catéter venoso central está encima de la carina y correcta respectivamente; el 90.5% de los resultados de posicionamientos correctos tienen una ubicación correcta de la punta del catéter central con respecto a la Carina, el 100% de las imágenes correctas presentan una ubicación correcta de la punta del catéter central con respecto a la Carina. El posicionamiento final de la imagen del paciente en su mayoría es correcta (90%), teniendo una ubicación de la punta del catéter venoso central correcta (63%) y una valoración de la imagen final en el control del catéter venoso central a la toma radiográfica correcta (89%). / Tesis

Page generated in 0.0525 seconds