• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de metodologia de baixo custo para determinação de glifosato usando microdispositivos eletroforéticos fabricados em poliéster-toner / Development of low cost methodology for determination of glyphosate using electrophoretic microdevices fabricated in polyester-toner

Silva, Eduardo Rodrigues da 15 April 2011 (has links)
Um grande crescimento no interesse por microdispositivos eletroforéticos tem sido observado nos últimos anos. Vantagens atrativas como baixo consumo de reagentes e diminutos tempos de analise são verificados. Microdispositivos fabricados usando toner de impressora e folhas de transparência (poliéster) vem a somar valores como baixo custo e simplicidade de confecção à técnica de micro-separação eletroforética. Entretanto, a aplicação analítica utilizando esse tipo de microdispositivo tem sido pouco explorada. <br />Neste trabalho o uso de microchips eletroforéticos fabricados em poliéster-toner (PT) é utilizado para a determinação simultânea do herbicida glifosato e seu maior metabólito, AMPA (ácido aminometilfosfônico). Em um primeiro momento, o trabalho apresenta o desenvolvimento de uma metodologia no qual utiliza condutometria sem contato (C4D) como sistema de detecção, aliada à separação eletroforética em microchips de PT. Vários parâmetros que regem uma boa confiabilidade analítica, tanto quanto otimizam a sensibilidade do sistema foram avaliados. <br />Em um segundo momento, ainda aliada à microchips de PT, a técnica de cronoamperometria foi utilizada como sistema de detecção. Nessa etapa do projeto estudos eletroquímicos foram inicialmente realizados em eletrodos convencionais de ouro e cobre, buscando averiguar qual metal apresenta maior sensibilidade para o herbicida glifosato. Tendo o metal cobre como melhor escolha, eletrodos planares foram construídos a partir da combinação das tecnologias da produção de máscaras de toner, e placas de circuito impresso como fonte de cobre. <br />Em ambas as metodologias desenvolvidas, picos bem resolvidos foram encontrados para os analitos em estudo. Tempos menores que 80 s foram gastos entre o processo de separação e detecção; uma boa repetibilidade também foi encontrada. Os valores de limite de detecção (LD) utilizando C4D foram 60,8 e 74,8 &micro;mol L-1 para glifosato e AMPA respectivamente. Como esperado, menores valores de LD foram obtidos na detecção amperométrica, com 1,88 &micro;mol L-1 para glifosato e 16,45 &micro;mol L-1 para AMPA. A aplicabilidade dos métodos foi verificada através da analise do herbicida e seu metabólito em amostras de água. Etapas de derivatização e pré-concentração off-line não foram usadas nesse trabalho, dessa forma os dois métodos desenvolvidos apresentaram como principais vantagens o extremo baixo custo, e a simplicidade de uso. / A large increase in interest in electrophoretic microdevices has been observed in recent years. Advantages attractive as low reagent consumption and low analytical time are checked. Microdevices fabricated using printer toner and polyester transparency sheets are the sum values as low cost and simplicity of the technique of making micro-electrophoretic separation. However, the analytical application using this type of microdevice has been little explored. <br />In this work the use of microchip electrophoresis fabricated on polyester-toner (PT) is used for the simultaneous determination of the herbicide glyphosate and its major metabolite, AMPA (aminomethylphosphonic acid). In a first moment, the work presents the development of a methodology in which the use capacitively coupled contactless conductivity detection (C4D) for determination of analytes is employed, coupled with electrophoretic separation in PT microchips. Several parameters that govern a good analytical reliability and with the intuit of optimizing the sensitivity of the system were evaluated. <br />In a second time and still allied to the PT microchips, the technique of chronoamperometry was used for detection. Electrochemical studies were initially conducted in conventional electrodes of gold and copper, looking for determine which metal is more sensitive to detect the herbicide glyphosate. Having the best choice planar copper electrodes were constructed from a combination of technologies for the production of toner masks, and printed circuit boards. <br />In both, C4D and chronoamperometric detection methodologies, well-resolved peaks were found for the glyphosate and AMPA. Time analysis of less than 80s were found including the separation and detection processes, and a good analytical repeatability was also found. The limits of detection (LOD) using C4D were 60,8 and 74,8 &micro;mol L-1 respectively for glyphosate and AMPA. As expected, lower LOD were obtained in the amperometric detection methodology, 1.9 &micro;mol L-1 for glyphosate, and 16.5 &micro;mol L-1 for AMPA. The applicability of the methods was tested by analyzing the herbicide and its metabolite in fortified water samples. Steps of derivatization and preconcentration off-line were not applied in this work, so the two methods showed as main advantages very low cost and time analysis, and simplicity of application.
2

Desenvolvimento de metodologia de baixo custo para determinação de glifosato usando microdispositivos eletroforéticos fabricados em poliéster-toner / Development of low cost methodology for determination of glyphosate using electrophoretic microdevices fabricated in polyester-toner

Eduardo Rodrigues da Silva 15 April 2011 (has links)
Um grande crescimento no interesse por microdispositivos eletroforéticos tem sido observado nos últimos anos. Vantagens atrativas como baixo consumo de reagentes e diminutos tempos de analise são verificados. Microdispositivos fabricados usando toner de impressora e folhas de transparência (poliéster) vem a somar valores como baixo custo e simplicidade de confecção à técnica de micro-separação eletroforética. Entretanto, a aplicação analítica utilizando esse tipo de microdispositivo tem sido pouco explorada. <br />Neste trabalho o uso de microchips eletroforéticos fabricados em poliéster-toner (PT) é utilizado para a determinação simultânea do herbicida glifosato e seu maior metabólito, AMPA (ácido aminometilfosfônico). Em um primeiro momento, o trabalho apresenta o desenvolvimento de uma metodologia no qual utiliza condutometria sem contato (C4D) como sistema de detecção, aliada à separação eletroforética em microchips de PT. Vários parâmetros que regem uma boa confiabilidade analítica, tanto quanto otimizam a sensibilidade do sistema foram avaliados. <br />Em um segundo momento, ainda aliada à microchips de PT, a técnica de cronoamperometria foi utilizada como sistema de detecção. Nessa etapa do projeto estudos eletroquímicos foram inicialmente realizados em eletrodos convencionais de ouro e cobre, buscando averiguar qual metal apresenta maior sensibilidade para o herbicida glifosato. Tendo o metal cobre como melhor escolha, eletrodos planares foram construídos a partir da combinação das tecnologias da produção de máscaras de toner, e placas de circuito impresso como fonte de cobre. <br />Em ambas as metodologias desenvolvidas, picos bem resolvidos foram encontrados para os analitos em estudo. Tempos menores que 80 s foram gastos entre o processo de separação e detecção; uma boa repetibilidade também foi encontrada. Os valores de limite de detecção (LD) utilizando C4D foram 60,8 e 74,8 &micro;mol L-1 para glifosato e AMPA respectivamente. Como esperado, menores valores de LD foram obtidos na detecção amperométrica, com 1,88 &micro;mol L-1 para glifosato e 16,45 &micro;mol L-1 para AMPA. A aplicabilidade dos métodos foi verificada através da analise do herbicida e seu metabólito em amostras de água. Etapas de derivatização e pré-concentração off-line não foram usadas nesse trabalho, dessa forma os dois métodos desenvolvidos apresentaram como principais vantagens o extremo baixo custo, e a simplicidade de uso. / A large increase in interest in electrophoretic microdevices has been observed in recent years. Advantages attractive as low reagent consumption and low analytical time are checked. Microdevices fabricated using printer toner and polyester transparency sheets are the sum values as low cost and simplicity of the technique of making micro-electrophoretic separation. However, the analytical application using this type of microdevice has been little explored. <br />In this work the use of microchip electrophoresis fabricated on polyester-toner (PT) is used for the simultaneous determination of the herbicide glyphosate and its major metabolite, AMPA (aminomethylphosphonic acid). In a first moment, the work presents the development of a methodology in which the use capacitively coupled contactless conductivity detection (C4D) for determination of analytes is employed, coupled with electrophoretic separation in PT microchips. Several parameters that govern a good analytical reliability and with the intuit of optimizing the sensitivity of the system were evaluated. <br />In a second time and still allied to the PT microchips, the technique of chronoamperometry was used for detection. Electrochemical studies were initially conducted in conventional electrodes of gold and copper, looking for determine which metal is more sensitive to detect the herbicide glyphosate. Having the best choice planar copper electrodes were constructed from a combination of technologies for the production of toner masks, and printed circuit boards. <br />In both, C4D and chronoamperometric detection methodologies, well-resolved peaks were found for the glyphosate and AMPA. Time analysis of less than 80s were found including the separation and detection processes, and a good analytical repeatability was also found. The limits of detection (LOD) using C4D were 60,8 and 74,8 &micro;mol L-1 respectively for glyphosate and AMPA. As expected, lower LOD were obtained in the amperometric detection methodology, 1.9 &micro;mol L-1 for glyphosate, and 16.5 &micro;mol L-1 for AMPA. The applicability of the methods was tested by analyzing the herbicide and its metabolite in fortified water samples. Steps of derivatization and preconcentration off-line were not applied in this work, so the two methods showed as main advantages very low cost and time analysis, and simplicity of application.
3

Extração e amplificação de RNA do vírus da dengue em microchips de poliéster-toner (PeT) / RNA extraction and amplification in polyester-toner (PeT) microchips

Gimenez, Thiago Dadalto 24 June 2016 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2016-08-25T18:05:35Z No. of bitstreams: 2 Dissertação - Thiago Dadalto Gimenez - 2016.pdf: 1825933 bytes, checksum: 5a60bb7603f0e0d32606fdd6c1e83d47 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-08-26T11:38:12Z (GMT) No. of bitstreams: 2 Dissertação - Thiago Dadalto Gimenez - 2016.pdf: 1825933 bytes, checksum: 5a60bb7603f0e0d32606fdd6c1e83d47 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-26T11:38:12Z (GMT). No. of bitstreams: 2 Dissertação - Thiago Dadalto Gimenez - 2016.pdf: 1825933 bytes, checksum: 5a60bb7603f0e0d32606fdd6c1e83d47 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-06-24 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Miniaturized analytical systems have been successfully used in many analytical and bioanalytical applications. In the field of clinical diagnoses, microfluidic devices can make analyses become faster, cheaper and more sensitive, and can also enable the performance of point-of-care tests. Diagnoses based in molecular biology techniques can be divided in three main steps (nucleic acid extraction, amplification and detection), and all these steps can be adapted for microscale. Here, we report the development of RNA analytical methods in disposable microdevices that may be further used in a micro total analysis system (μTAS). Analytical methods were developed for dengue virus detection, to enable RNA based molecular diagnoses in low cost devices. RNA extraction was carried out through a dynamic solid phase extraction (dSPE) methodology, by using magnetic silica particles. Extraction process occurs by performing three steps: RNA adsorption to the magnetic silica particles surface, washing of the beads and elution of purified RNA. PeT microchips used for RNA extraction were produced by printing, cutting and lamination of polyester films. Microchannels were 18 mm length and 1.2 mm width, and the volume of channels were 6.0 μL. High quality RNA, amplifiable by the reverse transcription polymerase chain reaction (RT-PCR) and reverse transcription loopmediated isothermal amplification (RT-LAMP), was obtained by dSPE. In addition to RNA extraction, the RNA detection by RT-LAMP in PeT devices was also demonstrated in this work. Amplified products were separated in agarose gel or detected by naked eye visualization after addition of fluorescent intercalant substances. The success of RNA extraction and amplification by RT-LAMP demonstrates the potential of PeT microdevices in performing molecular diagnosis for detection of pathogens whose genome is consisted by RNA. / Os sistemas analíticos miniaturizados vêm sendo utilizados com sucesso em muitas aplicações analíticas e bioanalíticas. No campo de diagnósticos clínicos, dispositivos microfluídicos podem tornar as análises mais rápidas, baratas, sensíveis, além de possibilitar a realização de exames no point-of-care. Diagnósticos baseados em técnicas de biologia molecular podem ser divididos em três etapas (extração, amplificação e detecção do ácido nucleico), sendo que todas essas etapas podem ser adaptadas para microescala. Este trabalho apresenta o desenvolvimento de métodos de análises de RNA em microdispositivos descartáveis que podem futuramente ser associados em microssistemas para análises totais (μTAS). As metodologias foram desenvolvidas para detecção do vírus dengue, a fim de possibilitar diagnósticos moleculares baseados em RNA viral em dispositivos de baixo custo e com as vantagens associadas à microfluídica. Para a extração do RNA utilizou-se uma metodologia de extração dinâmica em fase sólida (dSPE), com a utilização de partículas magnéticas de sílica. O processo de extração ocorre através da realização de três etapas: adsorção do RNA na superfície das partículas magnéticas de sílica, lavagem das partículas e eluição do RNA purificado. Os microchips de PeT utilizados na extração foram fabricados por impressão, corte dos canais e laminação dos filmes de poliéster. As dimensões dos canais foram 18 mm de comprimento e 1,2 mm de largura, sendo que o volume dos canais foi de 6,0 μL. RNA de alta qualidade, amplificável via reação em cadeia da polimerase pós transcrição reversa (RT-PCR) e amplificação isotérmica mediada por loop pós transcrição reversa (RT-LAMP), foi obtido através da dSPE. Além da extração do RNA, a detecção de RNA via RT-LAMP em dispositivos de PeT também foi demonstrada neste trabalho. Os produtos amplificados foram separados em gel de agarose ou visualizados a olho nu através da adição de intercaladores fluorescentes. O sucesso da extração de RNA e da amplificação via RT-LAMP demonstram o potencial dos microdispositivos de PeT na realização de diagnósticos moleculares para detecção de patógenos cujo genoma consiste de RNA.

Page generated in 0.0663 seconds