• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 256
  • 127
  • 27
  • Tagged with
  • 401
  • 143
  • 96
  • 74
  • 61
  • 55
  • 54
  • 41
  • 38
  • 29
  • 28
  • 28
  • 28
  • 27
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Mobile Magnetic Microrobots Control and Study in Microfluidic Environment : New Tools for Biomedical Applications / Contrôle et étude de microrobots magnétiques mobiles en milieu microfluidique : nouveaux outils pour le biomédicale

Salmon, Hugo 07 October 2014 (has links)
Dans le domaine du développement d'outils de micromanipulation de haute précision pour le biomédical, les microrobots mobiles immergés font figures de technologie émergente prometteuse pour des applications in-vitro, puis à plus long terme pour l'in-vivo. Mes travaux portent sur l'étude de la propulsion de microrobots par voie magnétique dans des fluides circulant dans des microcanaux, à une échelle où les phénomènes d'adhérence et d'amortissement prévalent. Leur application pour des opérations de transduction est développée dans un deuxième volet.Un dispositif d'asservissement par vision à haute fréquence d’échantillonnage (~5kHz) a été développé rendant possible le contrôle sous champ magnétique uniforme ou gradient. Les performances du système ont notamment demandé l’implémentation d'une interface multi-tâches afin de pouvoir acquérir et traiter les images en parallèle de l'actuation du robot. L'analyse de la dynamique permet de mieux appréhender les phénomènes parfois imprévisibles liés au déplacement du robot, MagPol, intégré dans une puce microfluidique. Il peut réciproquement servir de capteur dans son environnement fluidique.Ce design original de robot a été conçu pour la micromanipulation et permet également d'explorer des nouvelles stratégies de déplacement. Ces capacités ont été éprouvées sur des objets de même taille qu'en biologie cellulaire (billes, bulles).Enfin, une démonstration de l'asservissement visuel en planification de tâche a été effectuée. Sous réserve de posséder un algorithme suffisamment performant, l'échantillonnage haute fréquence en temps réel devient possible et l'observation de performances sur des trajectoires complexes est démontrée. Les performances, la portabilité et la reproductibilité du système démontrent des capacités de transduction à haut débit qui sont très prometteuses pour l'aspect applicatif. / In the research for new high performances tool for micrometric scale manipulation, mobile microrobots immersed are considered as a promising technology for in-vitro applications, and with a long term view in-vivo. My work focuses on the propulsion study of mobile microrobots immersed in microfluidic channels controlled through electromagnets. At this scale, surface and damping phenomena predominates. Application for transduction operation is developed in a second part.A high sampling rate (≈5kHz) visual servoing setup have been developed making a control possible through uniform and gradient magnetic field. Performances of the system have notably required a multi-thread programmed user interface to acquire and analyze the frame in parallel of the robot actuation. Dynamic analysis allow to better apprehend the perturbation dynamics of the robot MagPol, integrated in a microfluidic chip. It can reciprocally serve as a sensor for in fluidic environment.MagPol design has been originally conceived for micromanipulation, and also allows to explore new displacement strategies. Its capacities have been tested on beads and bubbles equivalent to cell biology characteristic size (10µm – 100µm).Finally, a demonstration of planned trajectory using visual servoing was accomplished. Though it has required an algorithm sufficiently efficient, high frequency real-time sampling is possible and lead to control and post observation on complex trajectory. Global performances, repeatability and portability of our system has demonstrated its capacities as a high-throughput transducer, promising for single microagent applications.
202

Conception d'un dispositif microfluidique de synthèse en continu du poly(acide acrylique) en milieu hétérogène eau/CO2 supercritique. / Development of a microfluidic device for the continuous synthesis of poly(acrylic acid) in a liquid water/supercritical CO2 system

Chen-Jolly, Hongyu 04 December 2014 (has links)
Ce travail de thèse rend compte de la mise en oeuvre d’un système de synthèse en continu dupoly(acide acrylique) en milieu CO2 supercritique (15 MPa et 75 °C). Nous avons conçu undispositif microfluidique résistant aux hautes pressions permettant l’écoulement de gouttes desolution aqueuse de monomère dans une phase continue constituée d’un mélangesupercritique d’éthanol dans du CO2 et contenant l’amorceur azobisisobutyronitrile (AIBN).Nous avons déterminé par spectroscopie IR la répartition des différentes espèces chimiquesdu mélange en fonction de la pression et la température, puis caractérisé la décompositionthermique de l’amorceur selon la composition du milieu réactionnel par spectroscopie UVVis.Enfin, nous avons montré que les gouttes sont comparables à des réservoirs demonomère alimentant sans cesse la phase continue. En raison de ce transfert rapide vis-à-visde la conversion de l’AA en chaîne polymère, la réaction de polymérisation s’effectuecontinûment avec un rapport molaire monomère sur amorceur constant durant tout le tempsde séjour dans le microcanal (jusqu’à 41 min). Une gamme large de masses molaires avec desindices de polymolécularité faibles a été obtenue : de 20 000 à 120 000 g.mol-1 pour 1,35 à1,70, en variant simplement les concentrations de monomère de la solution aqueuse initiale.Les paramètres expérimentaux influençant les propriétés du poly(acide acrylique) obtenu,ainsi que le lieu de la polymérisation ont été étudiés. / In this work, a continuous microfluidic device was developed to perform the synthesis ofpoly(acrylic acid) in supercritical CO2 (15 MPa and 75°C). This high pressure resistantdevice allows generating segmented flows in microcanal: an aqueous solution of monomerwas dispersed in a mixture of ethanol in CO2 containing initiator AIBN. The distribution ofdifferent components in this biphasic system has been determined by IR spectroscopyaccording to the pressure and the temperature. The thermal decomposition of AIBN indifferent reaction media has been investigated using UV-Vis spectroscopy. During thereaction, the droplets were used as reservoirs which insure the transfer of monomer to thecontinuous phase. Because of this rapid transfer compared to the reaction conversion, thepolymerization reaction was carried out continuously with a constant molar ratio betweenmonomer and initiator throughout the residence time (up to 41 min). It has been showed thata large range of molecular weights of poly(acrylic acid) (20 000 and 120 000 g.mol-1) withlow polydispersity index (1.35 à 1.70) can be obtained by just changing the initial monomerconcentration in the droplets. The effect of other parameters influencing the properties ofpoly(acrylic acid) as well as the locus of polymerization have been discussed.
203

Écoulement de mousse dans des modèles de milieux poreux / Flow of foams in models of porous media

Hourtané, Virginie 03 December 2014 (has links)
Pour augmenter le taux de récupération du pétrole, une des solutions chimiques utilisées consiste à injecter des mousses dans les milieux poreux. En effet, les mousses permettent sous certaines conditions de diminuer la mobilité et ainsi d’améliorer le balayage du réservoir. Cependant, les mécanismes contrôlant la mobilité des mousses ne sont pas bien compris. Nous proposons une approche microfluidique permettant une observation directe de l’écoulement des bulles dans un micromodèle de milieux poreux. Nous observons que l’écoulement n’est pas homogène dans le milieu poreux: il se fait uniquement dans quelques chemins. Le nombre de chemins préférentiels dépend de la qualité de la mousse et du nombre capillaire. Si nous simplifions le milieu poreux à une boucle, nous montrons que la formation des chemins préférentiels dépend de la taille de la boucle. En effet, les bulles sont bloquées dans la boucle uniquement quand la taille de la boucle est de l’ordre de grandeur de la taille des bulles. / Crude oil is already usually trapped into heterogeneous porous media. In order to increase the recovery efficiency, one of the chemical solutions consists in injecting foams in porous media to expel oil from the rock. Foam is indeed able in some cases to greatly decrease the mobility, leading to a better sweeping of the reservoir. However, the mechanisms controlling the foam mobility are not well known. We propose a microfluidic approach allowing a direct observation of the flow of bubbles in a model of porous media. We observe that the flow is not homogeneous in the porous medium: it is concentrated in some paths. The number of these preferential paths depends of the foam quality and the capillary number. If we simplify the geometry of the porous medium to a loop, we prove that the formation of preferential paths depends of the size of the loop. Indeed we can only immobilize the bubbles if the size of the loop is around the size of the bubbles.
204

Integration of functions dedicated to the mechanical solicitation and characterization of biological cells in microfluidic devices / Intégration de fonctions dédiées à la sollicitation et la caractérisation de cellules biologiques dans les dispositifs microfluidiques

Amirouche, Amin 25 October 2017 (has links)
Cette thèse vise à évaluer deux techniques différentes pour la distinction d'échantillons biologiques mécaniquement altérés. Les deux approches ont été mises au point et étudiées avec un objectif à long terme qui est l'application de ces méthodes au diagnostic basé sur le phénotype mécanique. Bien que, nous avons élaboré ces approches dans le cas de globules rouges (GR), comme leurs propriétés mécaniques peuvent être affectées par des pathologies importantes, tous les concepts développés dans ce travail peuvent être adaptés à d'autres types de cellules.Nous avons caractérisé les propriétés mécaniques de GR à l'aide d'une technique microfluidique passive. L'accent a été mis sur la relaxation de globules rouges sains (GRs) à la sortie d'un canal à largeur variante et la dépendance de la réponse mécanique aux conditions expérimentales a été démontrée. Nous avons rapporté deux modes de relaxation du GR en fonction des paramètres de l'écoulement, et nous avons utilisé l'interface entre ces deux modes pour remonter aux propriétés mécaniques du GR. Lors de la seconde approche, nous avons présenté les résultats obtenus au cours de l'étude du comportement mécanique des GRs à l'aide de l'électrodeformation. Nous avons étudié l'influence des paramètres expérimentaux sur la réponse cellulaire et conclu sur des conditions optimisées pour la sollicitation des cellules sans les altérer. Pour finir, nous avons fait le point sur l'évaluation de ces deux techniques dans la discrimination des échantillons mécaniquement défaillants des sujets sains. Les avantages et inconvénients des deux approches ont été discutés / This thesis aims at evaluating two different techniques for the distinction of mechanically impaired biological samples. Both approaches were developed and investigated keeping in mind the long term objective which is the application of these approaches to diagnosis based on cell mechanical phenotype. Although, we developed these approaches on Red Blood Cells as as their mechanical properties can be affected by important pathologies, all the concepts developed in this work can be adapted to other cell types.We characterized mechanically RBCs using a passive microfluidic technique. We focused on the shape relaxation of healthy Red Blood Cells (hRBCs) flowing out of an oscillating width channel and demonstrated the dependency of their mechanical response upon the experimental conditions. We reported the existence of two relaxation modes for RBCs depending on the flow parameters, we used the interface between the two modes to extract the mechanical properties of RBC.Using a second approach, we presented the results obtained during the study of the mechanical behavior of hRBCs using electrodeformation assays. We investigated the influence of the solicitation parameters on the cell response and concluded on optimized conditions for cell solicitation without altering them. Finally, we evaluated both techniques in the discrimination of rigidified samples from healthy couterparts. Advantages and drawbacks of both techniques were discussed
205

Test d'immunodiagnostic innovant combinant nanoparticules superparamagnétiques et micro-aimants / Development of tools and methods for a future magnetic "One STEP- ELISA"

Blaire, Guillaume 16 October 2014 (has links)
Les micro et nanoparticules magnétiques sont de plus en plus utilisées en biologie et en médecine, pour une large gamme d'applications. Plusieurs applications utilisent le piégeage et le guidage de ces billes sous l'effet d'un champ et d'un gradient de champ magnétique. Dans la plupart des applications, le champ magnétique est macroscopique, créé par un aimant ou un électro-aimant. L'intégration plus poussée est souvent envisagée, dans les articles scientifiques, par des microbobines ou par des éléments magnétiques doux. Ceux-ci doivent alors être polarisés par un champ externe (de nouveau, un électroaimant ou un aimant).Les micro-aimants mis au point à l'Institut Néel permettent d'obtenir les mêmes inductions que les meilleurs aimants du marché et, par conséquent, de par la réduction d'échelle, des gradients de champ intenses et donc des forces volumiques très conséquentes. Ils sont, de plus, favorables à l'autonomie et à la stabilité du système.Ce travail propose d'utiliser ces micro-aimants pour des applications en diagnostic In Vitro afin de tirer parti des forces volumiques importantes issues des micro-aimants et de la facilité d'utilisation de telles sources de champ magnétiques pour l'utilisateur.Ces premières constatations nous ont permis de mettre un place un test de type ELISA en une seule étape. Grâce à ces avantages, il a été possible d'utiliser des nanoparticules magnétiques à la place des classiques microparticules comme rapporté dans l'état de l'art. Ces nanoparticules, fonctionnalisables par des anticorps permettent entre autre d'augmenter le rapport surface sur volume phénomène très favorable à la sensibilité des tests de diagnostic In Vitro. De plus, les nanoparticules étant de petite taille, il est possible d'augmenter fortement leur concentration et de favoriser ainsi la capture de ces particules par les micro-aimants grâce à un mécanisme d'interaction fluide/particule et in fine la cinétique du test.Un autre avantage des micro-aimants permanents est la possibilité de contrôler le champ magnétique sur des distances micrométrique. Cela ouvre la voie à des tests de diagnostic sans lavage, simples et sensibles. Enfin, tous ces avantages ont été combinés à ceux de la microfluidique pour permettre l'émergence de test portables tout en restant efficaces. Pour cela l'autonomie intrinsèque aux micro-aimants permanents sera un avantage incontestable. / The range of applications for magnetic micro- and nanoparticles is constantly expanding, in particular in medicine and biology. A number of applications involve particle trapping and deviation under the effect of a magnetic field and field gradient. In most publications, the required magnetic fields are produced either using soft magnetic elements polarized by an external magnetic field, electromagnets or bulk permanent magnets.Micromagnets produce high fields and favor autonomy and stability while downscaling leads to an increase of field gradients and consequently increase strongly the forces.Micromagnets developped at the Neel Institute produce magnetic induction as good as the best macro-magnets. Therefore, thanks to scale reduction laws, high field gradients and therefore intense forces can be obtained. Moreover, these magnets can easily be integrated in micro systems such as BioMEMS.The purpose of this work is to use these micromagnets to develop in vitro immunoassays.. An innovative system based on superparamagnetic nanoparticles attraction by micromagnets was developed in order to perform a “one step” ELISA.Nanoparticles can be functionalized with antibodies, increasing the surface/volume ratio, and therefore the test sensitivity. Thanks to their small size, the nanoparticles concentration can be increased, and a fluid/particles interaction optimizes their capture by the micromagnets. This phenomena is favorable to immunoassay's kinetics.A micrometric control of the magnetic field is possible thanks to micromagnets: this allows to design simple and sensitive immunoassays that need no washing steps. Finally, these properties combined to microfluidics is used to design of point of care and sensitive immunoassays.
206

Développement d'une "biopuce à cellules" pour l'analyse des sécrétions de cytokines par les lymphocytes T individuels / Development of a "cell biochip" for the analysis of cytokine secretion by individual T-Lymphocytes

Baganizi, Dieudonné R. 04 December 2014 (has links)
Le système immunitaire est un ensemble de mécanismes impliquant différents types de cellules qui produisent des facteurs solubles (cytokines, chimiokines ou molécules cytotoxiques) qui contribuent à la régulation et aux réponses immunitaires. La caractérisation à l'échelle cellulaire de la production de ces facteurs solubles présente un grand intérêt d'une part sur le plan fondamental pour comprendre les cascades d'événements des régulations cellulaires, et d'autre part dans le suivi de la réponse immunitaire (infections, cancers, auto-immunités, greffes, vaccins, etc.). Cependant, la plupart des techniques actuellement disponibles (ELISpot, cytométrie en flux, microarrays, etc.) ne permettent pas d'étudier plusieurs cytokines en rapport avec le phénotype des cellules sécrétrices et/ou sans marquage et d'analyser les secrétions de cytokines en temps réel par des cellules individuelles. Dans cette étude, une « biopuce à cellules » a été développée pour analyser les secrétions de cytokines par les cellules individuelles (lymphocytes T) in vitro. La biopuce est fonctionnalisée par greffage électrochimique des motifs d'anticorps spécifiques aux protéines membranaires de cellules et/ou d'anticorps spécifiques aux cytokines, tous couplés au pyrrole. Ensuite, un traitement de surface est effectué avec du poly (éthylène glycol) thiol (Thiol-PEG) pour empêcher la fixation non spécifique de cellules sur la surface de la biopuce. Un dispositif microfluidique en polydimethyllsiloxane (PDMS) et maintenu à 37°C a aussi été développé afin d'intégrer toutes les opérations d'analyse et de détection dans un seul système. La biopuce développée dans cette étude permet la capture spécifique et stable de lymphocytes T individuels viables et la détection ultérieure de cytokines sécrétées par chaque cellule individuelle. Dans ce travail, la détection des cytokines sécrétées (IL-2 et IFN-γ) a été effectuée par fluorescence dans un format en sandwich. Cette «biopuce à cellules» est également compatible avec l'imagerie par résonance plasmonique de surface (SPRi), ce qui pourrait permettre de réaliser des analyses en temps réel et la détection sans marquage de plusieurs cytokines sécrétées par des cellules individuelles. Cette technique fournit un outil très prometteur pour l'analyse de marqueurs biologiques et de l'activité de cellules et l'étude des réponses immunitaires. / The immune system is a set of mechanisms involving many different cell types which communicate through downstream signals mediated principally by soluble factors (i.e. cytokines) to protect the host against invading organisms and to control adequate immune responses. The identification and characterization at the cellular level of cytokine production has a huge interest for both fundamental research and clinical studies. However, the majority of techniques currently available (ELISpot, flow cytometry, microarrays, etc.) have several shortcomings including notably the assessment of multiple cytokines in relation to secreting cell phenotypic classification and/or label-free and real-time analysis of cytokine secretions at individual cell level. Hence, in this study, we developed a « cell biochip » to analyze the secretion of cytokines by individual cells (T lymphocytes) activated and cultured in vitro. The biochip is functionalized by electrochemically grafting patterns of pyrrole-conjugated cell membrane-specific and cytokine-specific antibodies and treated with Poly(ethylene glycol)thiol (Thiol-PEG) self-assembled monolayers (SAMs) to stably avoid non-specific binding of cells on the surface. A polydimethyllsiloxane (PDMS)-based microfluidic device maintained at 37°C was also developed in order to integrate all the detection assay operations in a single system. The biochip developed here allows specific and stable capture of viable and bioactive individual T cells and subsequent detection of secreted cytokines in the close vicinity of each individual cell. In this work, the detection of secreted cytokines (IL-2 and IFN-γ) was performed by fluorescence in an immunosandwich assay format. This « cell biochip » is also compatible with surface plasmon resonance imaging (SPRi), which could therefore allow expanding its functionality to enable real-time and label-free detection of multiple cytokines from individual cells. Such technique provides a very promising tool for the analysis of biomarkers and cell activity and the monitoring of immune responses.
207

Etude des propriétés de nanoparticules de LiCoO2 en suspension pour une application redox-flow microfluidique / Study of LiCoO2 nanoparticles suspensions for a microfluidic redox-flow application

Rano, Simon 25 September 2017 (has links)
Ce travail de thèse porte sur la réalisation d’une batterie redox-flow fonctionnant grâce à la circulation de suspensions de matériaux d’insertion du lithium afin d’accroitre leur densité d’énergie. Le recours à des cellules microfluidiques permet de s’affranchir des limitations causées par les membranes échangeuses d’ions. Il s’articule dans un premier temps sur la synthèse contrôlée par voie hydrothermale de nanoparticules de LiCoO2 et leur caractérisation en suspension aqueuses. Cette étape permet de déterminer à la fois les propriétés électrochimiques des suspensions, leur état d’agrégation ainsi que leur comportement rhéologique en vue d’une utilisation redox-flow. Le transfert électronique entre une particule en suspension et les électrodes de la cellule est un aspect fondamental de ce type de batteries. Ce transfert est étudié grâce la technique de collision électrochimique dans laquelle la réponse de chaque agrégat est détecté individuellement par une ultramicroélectrode ce qui permet d’établir de nombreuses propriétés physique-chimiques de ces suspensions. Ce travail propose ensuite de s’affranchir de l’utilisation des membranes et de leurs limitations par le recours aux techniques de la microfluidique. La formation d’un écoulement co-laminaire en microcanal permet d’obtenir une cellule redox-flow opérationnelle. La conception et le fonctionnement de ces cellules est étudié en vue de la mise en circulation de suspensions de nanoparticules dans ce type de systèmes. / The aim of this work is to make a redox-flow battery that runs on lithium insertion material suspensions in order to increase the energy density of such systems. The use of microfluidic technics allows to solve the issues and limitations of ion exchange membrane by removing them. In the first part controlled size LiCoO2 nanoparticles are synthesized by hydrothermal route and dispersed into suspensions. The aggregation state of these suspensions are investigated using diffusion light scattering and transmission electronic cryoscopy. Rheological properties were also characterized for redox-flow use. The electronic transfer between a particle in suspension and the flow cell electrodes is crucial for their performances. This transfer is studied in the second part using the single event collision technic which consist of isolating individual aggregate electrochemical response at the surface of an ultramicroelectrode. This approach allows an extensive investigation of suspensions aggregates size, mobility and insertion reaction kinetic. Finally this works propose to replace the conventional ion exchange membrane by the mean of microfluidic technics. In co-laminar condition the fluid interface acts as a separation membrane to create a membrane-less redox-flow battery. The last part focuses on the fabrication of microfluidic cells and the behavior of suspensions in micro-channels.
208

Développement de microtechnologies pour l'étude du guidage axonal / Development of microtechnologies for the study of axonal guidance

Lecomte, Yohan 28 June 2019 (has links)
Le guidage axonal est un processus très important dans le développement du cerveau, permettant de lui donner sa structure et son organisation. La communauté scientifique des neurosciences lui porte un intérêt grandissant ces dernières années. Plusieurs outils appartenant au domaine des microtechnologies, que sont la microfluidique et le micropatterning, sont d’une aide importante pour étudier le guidage axonal in vitro. Ils permettent de confiner les neurones et leurs axones et de leur appliquer des gradients de molécules de guidage. Lors de ce travail de thèse, j’ai voulu développer un système pour étudier l’effet de gradients de molécules de guidage sur le guidage axonal. J’ai pour cela testé plusieurs configurations de dispositifs microfluidiques, de micromotifs (micropatterns) et de combinaisons de ces derniers.Nous avons d’abord utilisé deux approches pour isoler les axones de neurones dissociés de leurs somas afin de pouvoir étudier, à haut débit, l’effet de l’environnement moléculaire sur les cônes de croissance des neurones. La première approche consistait à faire pousser des neurones sur des motifs (patterns) de différentes protéines. Elle a permis de montrer leur capacité d’adhésion spécifique sur ces motifs. La seconde consistait à ensemencer des neurones dans un dispositif microfluidique dans lequel, lors de leur pousse, les axones sont séparés des somas par des microcanaux. Nous avons ensuite étudié l’effet, sur les axones, de gradients de molécules de guidage. Pour commencer, nous avons mesuré l’effet de deux molécules de guidage : l’éphrine et la sémaphorine, en cultivant des neurones en présence de gradients patternés de ces deux molécules. Par la suite, nous avons étudié un autre modèle où les neurones sont plus proches de leur environnement in vivo, des explants poussant sur des motifs de laminine contenant un gradient. Pour aider au positionnement de l’explant, nous avons polymérisé des hydrogels. Ensuite, nous avons mis des explants à côté de gradients patternés d’éphrine. Enfin, nous avons cherché à obtenir un gradient soluble de molécules de guidage entretenu sur des temps longs, plus proche des gradients existant in vivo. Dans ce but, nous avons voulu fabriquer un dispositif microfluidique permettant d’appliquer un gradient soluble de molécules de guidage sur des neurones. Pour obtenir un gradient stable dans le temps, nous avons aussi cultivé des neurones à côté de cellules exprimant la nétrine, une autre molécule de guidage. Pour finir, nous avons cultivé des neurones et des glies dissociés pour étudier leurs interactions.L’ensemble de ces recherches n’a pas permis d’obtenir un dispositif fiable pour étudier l’effet de molécules sur la pousse et le guidage des axones. Néanmoins, la configuration consistant en une coculture de neurones à proximité de cellules relargant de la nétrine nous a permis d’obtenir des premiers résultats encourageants. Nous avons ainsi mis au point un ensemble de méthodes qui pourront nous permettre de finaliser le développement d’un système pour étudier le guidage axonal, fonctionnel et efficace. / Axonal guidance is a very important process during brain development, allowing to give it its structure and organization. The neuroscience scientific community has a growing interest in it during the last years. Several tools belonging to the field of microtechnologies, microfluidics and micropatterning are of important help to study axonal guidance in vitro. They allow to confine neurons and their axons and to apply gradients of guidance molecules. During this thesis, my goal was to develop a system to study the effect of guidance molecules gradients on axonal guidance. For that, I tested several configurations of microfluidic devices, micropatterns and combinations of both.First, we used two approaches to isolate dissociated neurons axons from their somas. Our goal was to study the effect of the molecular environment on neurons growth cones, with a high throughput. The first approach consisted in growing neurons on different proteins patterns. It also allowed to show their capacity to adhere on these patterns. The second one consisted in seeding neurons in a microfluidic device in which, during their growth, axons are separated from somas by microchannels. Then we studied the effect, on the axons, of guidance molecules gradients. To begin, we measured the effect of two guidance molecules: ephrin and semaphorin, by culturing neurons in the presence of patterned gradients of these two molecules. After that, we studied another model where neurons are closer from their environment in vivo, explants growing on laminin patterns containing a gradient. To help the explant positioning, we polymerized hydrogels. Then, we put explants next to patterned gradients of ephrin. Finally, we tried to obtain a soluble gradient of guidance molecules, over a long period of time (days), closer to existing gradients in vivo. In that goal, we wanted to build a microfluidic device enabling the application of a soluble gradient of guidance molecules on neurons. To obtain a constant gradient, we also cultured neurons next to cells expressing netrin, another guidance molecule. Finally, we cultured dissociated neurons and glial cells to study their interactions.All these experiments did not allow to obtain a reliable device to study the effect of molecules on axons growth and guidance. Nevertheless, the configuration consisting in a coculture of neurons next to cells releasing netrin allows us to obtain promising preliminary results. We thus drew up a group of methods that will enable us to finalize the development of a system to study axonal guidance, functional and efficient.
209

Dynamique de vésicules en écoulement

Mader, Maud-Alix 21 December 2006 (has links) (PDF)
Dynamique de suspensions de vésicules et de globules rouges en écoulement de cisaillement simple et en microfluidique.
210

Matériaux amorphes : des solides qui coulent de façon collective

Goyon, Julie 07 October 2008 (has links) (PDF)
Le but de ce travail expérimental est de caractériser l'écoulement d'émulsions dans différentes géométries. Grâce à deux dispositifs expérimentaux (une cellule de Couette d'entrefer de 1,8 cm et des canaux microfluidiques dont la dimension caractéristique varie de 250 à 56 Μm) associés à deux techniques de vélocimétrie résolues spatialement (l'imagerie par résonance magnétique et la vélocimétrie par suivi de particules), nous avons mis en évidence des phénomènes non locaux dans l'écoulement d'émulsions concentrées en milieu confiné. Nous avons étudié l'influence la rugosité des surfaces confinant l'écoulement et la largeur des canaux microfluidiques dans lequel s'écoule l'émulsion. Nous avons, au cours de ce travail, développé un modèle microscopique scalaire qui rend compte des phénomènes expérimentaux obtenus. La non localité est quantifiée par une longueur 6, caractéristique de la coopérativité de l'écoulement. Cette longueur est typiquement de quelles tailles de gouttes. Elle est nulle pour une émulsion diluée et augmente avec la fraction volumique en huile pour les émulsions concentrées. Nous avons étudié trois émulsions afin de mettre en évidence l'influence de la taille des gouttelettes et de leur polydispersité sur la longueur caractéristique de la coopérativité de l'écoulement.

Page generated in 0.0886 seconds