Spelling suggestions: "subject:"microscopia eletrônico dde varredura"" "subject:"microscopia eletrônico dee varredura""
191 |
Influência do tipo de pilar de resistência mecânica pré-ciclagem, quantidade de toque retido e desajuste vertical pré e pós-ciclagem, com análise estrutural em MEVButignon, Luís Eduardo [UNESP] 20 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-07-20Bitstream added on 2014-06-13T19:05:07Z : No. of bitstreams: 1
butignon_le_dr_arafo.pdf: 1153386 bytes, checksum: 16702ac969f619bac97fc05d42b19652 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Problemática: De ocorrência clínica comum, o afrouxamento dos parafusos que compõe uma prótese sobre implante é uma complicação que traz transtornos tanto para o profissional quanto para o paciente. Entre os fatores que interferem na estabilidade da união parafusada destaca-se a pré-carga gerada durante o torque do parafuso, as formas como as forças se dissipam através do conjunto implante/pilar/parafuso e as características dos componentes utilizados. Proposição: O objetivo deste estudo foi analisar comparativamente três tipos de pilares sobre implantes, quanto a resistência mecânica previamente ao ensaio de carga cíclica; a porcentagem de torque retido na união parafusada e os níveis de desajuste vertical entre o pilar e o implante antes e após ciclagem; e alterações estruturais na base de assentamento dos pilares através de microscopia eletrônica de varredura (MEV). Material e método: Quarenta e cinco implantes, com conexão tipo hexágono externo foram incluídos em cilindros de PVC utilizando-se resina epóxica com módulo de elasticidade semelhante à estrutura óssea. Os grupos foram estabelecidos de acordo com o tipo de pilar utilizado (n=15): Titânio (pré-fabricado), Ouro (com cinta metálica pré-fabricada e sobre fundido) e Zircônia (pré-fabricado). Cinco pilares de cada grupo foram submetidos a teste de resistência estática para estabelecimento do valor da força a ser utilizada no ensaio de carga cíclica. Os outros 10 pilares de cada grupo foram fixados sobre os respectivos implantes através de parafuso de titânio, sob torque e retorque de 32 Ncm (pilares metálicos) e 20 Ncm (pilar de zircônia). Os corpos de prova foram submetidos à aferição do torque retido (précarga) e dos níveis de desajuste vertical... / Purpose: The aim of this study was to evaluate comparatively three type of abutment in regard to mechanical resistance before cyclic loading, the maintenance of the applied torque and vertical misfit in abutment/implant interface before and after cyclic loading, and damage surface by SEM. Material and Method: Forty five external hex implants were embedded in an epoxy resin and received your respective abutments, randomly divided in three experimental groups (n=15): (A) machined titanium (Ti) abutments; (B) premachined gold (Au) abutments and (C) machined zirconia (ZrO2) abutments. For all groups, only one type of screw was used. The abutment screws were tightened according to the manufacture’s recommended torque. Initially, a static bending test was performed using 5 specimens of each group to determine the load applied in the cyclic loading test. Thus, 10 specimens of each group were used to measure the reverse torque value (preload) of the abutment screw and vertical gap between the abutments and implant, before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106 cycles; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were compared using ANOVA and Tukey test. Result: The mechanical strength test showed that the UFL mean for Au abutments was significantly higher than the mean of the other abutments (p<0.001). The analysis of reverse torque (preload) before cyclic loading showed no significant differences among abutment groups. After cyclic loading the lowest decrease in preload was observed in group Ti, whereas the highest was observed in group ZrO2, with significant differences between them. The group Au showed an intermediate decrease, with no significant difference to the other groups. In relation to the vertical misfit... (Complete abstract click electronic access below)
|
192 |
Estudo da variabilidade e diferenças morfológicas entre as espécies Cryptococcus neoformans e Cryptococcus gattii por análise de diferença representacional e microscopia eletrônica de varreduraFaganello, Josiane January 2008 (has links)
Cryptococcus neoformans e Cryptococcus gattii são leveduras do grupo dos basidiomicetos que causam criptococcose em indivíduos imunocomprometidos e imunocompetentes, respectivamente. Ambas as espécies são caracterizadas por diferenças moleculares, imunológicas, fisiológicas e epidemiológicas. Visando identificar diferenças morfológicas, foi desenvolvido um procedimento de preparação alternativo para análise de C. neoformans e C. gattii por MEV (Microscopia eletrônica de varredura) fixando as células diretamente na cultura em ágar. Este método é mais simples do que os outros já publicados e a morfologia das células foi bem preservada. Neste trabalho também foi realizado o método de RDA (Análise de diferença representacional) com o objetivo de isolar seqüências que representam diferenças no DNA genômico de C. neoformans var. grubii e C. gattii. Aproximadamente 200 clones foram seqüenciados permitindo a identificação de 19 seqüências diferentes com significante similaridade (Evalue < 10-5) com o genoma completamente seqüenciado de C. neoformans var. neoformans linhagem JEC21. A maioria das seqüências identificadas representa proteínas hipotéticas ou proteínas de função desconhecida. Experimentos de Southern blot com cinco clones selecionados confirmaram a presença de polimorfismos ou especificidade para C. gattii. Os dados de seqüenciamento de uma das regiões identificadas como polimórficas, IDE (do inglês, insulin degrading enzime), foram usados juntamente com os dados de seqüenciamento de outros 3 loci (ACT1, URA5, PLB1) para estudar as relações filogenéticas entre as espécies. O locus IDE mostrou-se mais conservado entre diferentes tipos moleculares do que os outros loci estudados, e as variações intra-variedades em C. gattii são maiores do que em C. neoformans. Estes resultados sugerem que o RDA é um método eficiente para isolar regiões polimórficas de leveduras e suportam o conceito de duas espécies reconhecido atualmente para o complexo C. neoformans. / Cryptococcus neoformans and Cryptococcus gattii are basidiomycetous yeasts that cause cryptococcosis in immunecompromised and immunecompetent individuals. Both species are characterized by biochemical, immunological, molecular and epidemiological differences. Aiming to identify morphological differences, we propose an alternative to conventional preparation procedures for scanning electron microscopy (SEM) analysis of C.neoformans and C. gattii was done fixing the cells directly in the agar culture. This method is simpler than others already reported and the morphology of the cells was well preserved. We also applied representational difference analysis (RDA) to isolate sequences representing genomic differences between C. neoformans var. grubii and C. gattii. Approximately 200 clones were sequenced leading to the identification of 19 different sequences with significant similarities (Evalue< 10-5) to the completely sequenced genome of the C. neoformans var. neoformans JEC21 strain. Most of the identified sequences represent hypothetical proteins or proteins of unknown function. Southern blot experiments using five selected clones confirmed the presence of polymorphisms or specificity to C. gattii. The polymorphic IDE (insulin degrading enzyme, putative) sequence data were used together with the DNA sequence data of other 3 loci (ACT1, URA5, PLB1) for studying phylogenetic relationship between species. The IDE locus was exceptionally conserved among individual molecular types compared with other loci, and intra-varieties variations in C. gattii is higher than in C. neoformans. Our results suggest that RDA provides an efficient way to isolate polymorphic regions from yeasts and highly supports the two species concept recognized currently.
|
193 |
Síntese e caracterização de nanocristais de calcopirita CuIn(S1- xSex)2 para aplicação em células solares visando produção de energia limpaMagalhães, Pedro Paulo Silva 30 June 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Biológicas, Pós-Graduação em Nanociência e Nanobiotecnologia, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-07-19T15:24:33Z
No. of bitstreams: 1
2017_PedroPauloSilvaMagalhaes.pdf: 5013198 bytes, checksum: afc1f62e46a8f51a3ed2ba163b23481e (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-09-19T14:26:34Z (GMT) No. of bitstreams: 1
2017_PedroPauloSilvaMagalhaes.pdf: 5013198 bytes, checksum: afc1f62e46a8f51a3ed2ba163b23481e (MD5) / Made available in DSpace on 2017-09-19T14:26:34Z (GMT). No. of bitstreams: 1
2017_PedroPauloSilvaMagalhaes.pdf: 5013198 bytes, checksum: afc1f62e46a8f51a3ed2ba163b23481e (MD5)
Previous issue date: 2017-09-19 / Neste trabalho, apresenta-se o estudo experimental de síntese e caracterização de nanoestruturas de calcopirita CuIn(S1-xSex)2. A série com x = 0, 0.5 e 1.0 foi preparada a partir do método solvotermal (decomposição térmica) em atmosfera de argônio. Posteriormente à síntese, as propriedades estruturais e morfológicas das amostras foram examinadas por difração de raios X (DRX), microscopia eletrônica de transmissão (MET) e de varredura (MEV) e análise por microssonda (EDS). As propriedades ópticas e vibracionais foram examinadas utilizando a espectroscopia de ultra-violeta (UV-VIS), a espectroscopia Raman e infravemelho (FTIR). Os resultados da caracterização por análise de microssonda (EDS) confirmaram as concentrações nominais de Cu, In S e Se nas amostras. As análises dos difratogramas indicaram que todas as amostras em pó da série (x = 0, 0.5 e 1.0) e o filme da série (x = 0) formaram na estrutura cristalina tipo calcopirita com grupo espacial I42-d. Os parâmetros de rede e o volume da célula unitária mostraram um comportamento linear com a concentração de x, o qual pode ser explicado utilizando a Lei de Vegard. Se determinou um aumenta do volume da célula unitária de 339.84 Å 3 para a amostra com x=0 e de 388.44 Å 3 para a amostra com x=1, ou seja, um aumento de 12,5 % do volume da célula unitária. Em relação à caracterização por microscopia eletrônica de transmissão (MET), para a amostra de CuInS2 obteve-se um tamanho médio de ~30 nm. Este tamanho é superior quando comparado ao valor médio de cristalitos de ~20 nm estimado usando a fórmula de Scherrer na análise dos dados de DRX. Para a amostra CuIn(S0.5Se0.5)2 obteve-se um tamanho médio de ~3.6 nm que também é inferior quando comparado ao valor médio de ~6 nm dos critalitos obtido da análise dos dados de DRX. Já para a amostra de CuInSe2 obteve-se um tamanho médio de ~36 nm, comparável ao valor médio estimado por DRX. A caracterização por espectroscopia UV-VIS foi usada para determinar o gap de energia (Eg) de cada material sintetizado usando a lei de Tauc para sistemas de gap direto. Os valores estimados de Eg foram inferiores aos reportados na literatura, mas estes valores de Eg mostram um decrescimento linear quando a concentraçao de Se é incrementada nas amostras. O valor baixo de Eg está provavelmente relacionado com a presença de estruturas indesejáveis e/ou devido à presença de resíduos orgânicos resilientes. Medidas de espectroscopia Raman das amostras CuIn(S1-xSex)2 ajudaram a identificar os modos vibracionais característicos da estrutura calcopirita. Além disso, ajudou a identificar a formação de fases extras ou estruturas binárias ou ternárias que não se transformaram na fase calcopirita desejada. A análise dos dados de FTIR possibilitou detectar a presença dos grupos funcionais de estruturas orgânicas, mesmo após o processo de lavagem e centrifugação nas amostras em pó e após a calcinação da amostra em filme. / In this work, we present na experimental study of the syntesis and characterization of chalcopyrite CuIn(S1-xSex)2nanoestructures. A series with x=0, 0.5 and 1.0 were prepared following a solvothermal (thermal decomposition) method using an argon atmosphere. After the systhesis, the structural and morphological properties of the samples were determined using X-ray diffraction (XRD), Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). The optical and vibrational properties were determined using UV-Vis, Raman and Fourier-transform infra-red (FTIR) spectroscopies. EDS results confirmed the nominal concentrations of Cu, In, S and Se elements in the samples. The analysis of the diffractograms indicated that all powder samples (with x=0, 0.5 and 1.0) and the film with x=0 form in a chalcopyrite crystalline structure with a space group I42-d. The lattice constants and the unit cell volume show a linear dependence with x, which can be explained using the Vegard’s law. The unit cell volume was 339.84 Å 3 for x=0 and becomes 388.44 Å 3 for x=1.0, in other words, a volume increase of 12.5%. From the microscopic characterization, results from TEM analysis indicated a mean particle size of ~30 nm for the CuInS2 sample. This value is larger when compared to the mean crystallite size of ~20 nm estimated from XRD data analysis using the Scherrer relation. A mean size of ~3.6nm was determined for the sample CuIn(S0.5Se0.5)2, which is smaler than the mean crystallite size of ~6nm determined form XRD data analysis. However, for the sample CuInSe2 the mean size of ~36 nm determined from TEM data analysis is consistent with the mean crystallite size determined from XRD data. The UV-Vis spectroscopy measurements were used to determine the band gap energy (Eg) of the samples using the Tauc’s law for direct bandgap systems. Although the estimated values of Eg are relatively lower when compared to the values reported in the literature for compounds with the same stoichiometry, the Eg shows a clear linear decrease as the Se concentration is increased in the samples. The lower values of Eg are likely related to the formation of additional structures and/or due to the presence of resilient organic products. Raman spectroscopy measurements of samples CuIn(S1-xSex)2 helps to identify characterisitc vibrational modes which correspond to the chalcopyrite phase. Besides, other modes that correspond to extra phases or binary or ternary strutures which did not transform to the chalcopyrite phase. From FTIR data analysis, we detected the presence of functional groups of organic structures which remain even after the washing and centrifugation process for the powder samples and after the calcination process for the film.
|
194 |
Estruturas tipo granada sob alta pressão e temperaturaRovani, Pablo Roberto January 2010 (has links)
No presente trabalho, amostras monofásicas de granada (TR3Fe5O12, onde TR = Y, ou Eu, ou Gd) foram obtidas por moagem de alta energia, seguida de tratamento térmico, de misturas estequiométricas de sesquióxidos (Fe2O3 + Gd2O3, Fe2O3 + Eu2O3 e Fe2O3 + Y2O3). Essas amostras foram pré compactadas e processadas em altas pressões, essencialmente nos patamares de 2,5 e 7,7 GPa. Em alguns casos, simultaneamente à aplicação da alta pressão, foram feitos tratamentos térmicos moderados, em 500 e 1000°C. Os produtos desses processamentos, corpos cilíndricos com boa resistência mecânica, foram analisados por difratometria de raios X, espectroscopia Raman, microscopia eletrônica de varredura e medidas de microdureza Vickers. Nessas análises, foi verificado um comportamento sistemático para os sistemas de diferentes constituições químicas. Salvo pequenas variações da faixa de estabilidade, foi observada, em alta pressão e temperatura, a decomposição da fase granada em uma mistura de fases óxidas mais simples. Os parâmetros de processamento podem ser ajustados para obtenção de peças sinterizadas, altamente densificadas, constituídas puramente da fase granada ou de uma mistura homogênea de fases do tipo perovskita e hematita. / In this work, monophasic garnet samples (TR3Fe5O12, where TR = Y, or Eu, or Gd) were synthesized by high energy ball milling followed by thermal treatment of stoichiometric mixtures of sesquioxides (Fe2O3 + Gd2O3, Fe2O3 + Eu2O3 and Fe2O3 + Y2O3). The obtained garnet samples were pre-compacted and processed under high pressure (2,5 and 7,7 GPa). In some cases, the samples were submitted to moderate thermal treatments (500 and 1000°C) simultaneously to the application of high pressure. The obtained cylindrical bodies with good mechanical resistance were analysed by X-ray diffractometry, Raman spectroscopy, scanning electron microscopy and Vickers micro-hardness. Except by small variations in the stability range, a systematic behavior was verified for the different garnet samples. The high pressure/high temperature treatment induced the decomposition to a mixture of simpler oxide phases. The processing parameters can be chosen to produce highly densified sintered bodies containing only the garnet phase or an homogeneous mixture of hematite and a perovskite-type phase.
|
195 |
Efeito do laser ER:YAG e ponta diamantada na morfologia da camada híbrida obtida com um adesivo autocondicionante : resistência de união ao microcisalhamento análise por MEV e MLCF /Gonçalves, Aline de Oliveira. January 2013 (has links)
Orientador: Osmir Batista de Oliveira Junior / Banca: Mirian Lacalle Turbino / Banca: Edson Alves de Campos / Resumo: Este estudo tem como objetivo avaliar o efeito de laser de Er: YAG (L) e ponta diamantada (B) sobre a força de resistência ao microcisalhamento (MPa) e o efeito sobre a interface adesiva de adesivos condiciona e lava (CL) - Adper Scotchbond Multiuso e autocondicionante (CS) - Adper EasyOne, ambos da 3M ESPE. Foram constituídos 4 grupos segundo instrumentos e adesivos: B_CL (controle); B_CS; L_CL e L_CS. 60 incisivos bovinos foram randomicamente divididos nos experimentos e grupos: 40 para força de resistência ao microcisalhamento (n=10) e 20 para morfologia da interface adesiva (6 para mensuração da espessura da camada hibrida (CH) e comprimento de tags (t) por MLCF (n=3); 12 para morfologia da interface adesiva por MEV (n=3) e 2 para ilustração o efeito dos instrumentos sobre dentina por MEV (n=1). Para o ensaio de microcisalhamento foram confeccionados 4 cilindros de resina composta Filtek Z350 XT - 3M ESPE (0,7 mm de diâmetro por 1 mm de altura e área de adesão de 0,38 mm2) sobre cada superfície de dentina tratada pelos instrumentos e adesivos. O ensaio de resistência de união ao microcisalhamento foi realizado em máquina de ensaio universal EMIC 2000, com célula de carga de 500 Kgf e velocidade de 0,5 mm/min. A interface adesiva foi caracterizada pela espessura da camada hibrida (CH) e comprimento de tags (t) em μm, com o software UTHSCSA Imagetool. Os valores de resistência adesiva ao microcisalhamento foram L_CL 34,10 ± 19,07 MPa, B_CL 24,26 ± 9,35 MPa, L_CN 33,18 ± 12,46 MPa, B_CN 21,24 ± 13,96 MPa. Anova two-way resultou em diferença estatisticamente significativa somente para instrumentos (p=0,047). Teste de Mann-Whitney identificou os instrumentos determinam diferenças significativas para de espessura de CH e comprimento de (t). Para adesivos estas diferenças só foram observadas para (t). Pode-se concluir que 1) Laser de Er:YAG resulta em maiores valores de... / Abstract: This study aims to evaluate the effect of Er: YAG (L) and bur (B) on the strength of resistance microshear (MPa) and the effect on the interface adhesive stickers and wash conditions (CL) - Adper Scotchbond Multipurpose and self (CS) - Adper EasyOne, both from 3M ESPE. Were formed 4 groups according tools and adhesives: B_CL (control); B_CS; L_CL and L_CS. 60 bovine incisors were randomly divided into experimental and groups: 40 to force microshear resistance (n = 10) and 20 for the adhesive interface morphology (6 to measure the thickness of the hybrid layer (CH) and length of tags (t) by MLCF (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1). Microshear For testing four cylinders were fabricated composite Filtek Z350 XT - 3M ESPE (0.7 mm in diameter and 1 mm in height and area of adhesion of 0.38 mm) on each dentin surface treated by tools and adhesives. Testing of bond strength was performed in microshear FDMS universal testing machine 2000 with a load cell of 500 kgf and a speed of 0.5 mm / min. Adhesive interface was characterized by layer thickness hybrid (HC) and length of tags (t) in nm, with software UTHSCSA ImageTool. Values of bond strength to microshear L_CL were 34.10 ± 19.07, 24.26 ± 9.35 B_CL, L_CN 33.18 ± 12.46, 21.24 ± 13.96 B_CN. Anova two- way resulted in statistically significant only for instruments (p = 0.047). Mann-Whitney identified instruments to determine significant differences CH thickness and length (t). adhesives for these differences were only observed for (t). It can be concluded that 1) Laser Er: YAG results in higher bond strength to the microshear, regardless of the adhesive system (CL and CS). 2) The tags have no significant effect on bond strength to microshear. 3) The adhesive interface is affected by both instruments for cavity preparation and the type of adhesive system... / Mestre
|
196 |
Strain rate dependent behavior of composite materials and epoxy / Comportamento dependente da ração de deformação de materiais compósitos e epóxiHernandez Baltodano, Dany Arnoldo [UNESP] 15 March 2017 (has links)
Submitted by DANY ARNOLDO HERNÁNDEZ BALTODANO (danyhdzb@hotmail.com) on 2017-04-18T19:13:44Z
No. of bitstreams: 1
Thesis Dany Hernandez.pdf: 2171039 bytes, checksum: 8f2efded7710ccbd5aed9274952116a7 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-04-18T20:27:33Z (GMT) No. of bitstreams: 1
hernandezbaltodano_da_me_bauru.pdf: 2171039 bytes, checksum: 8f2efded7710ccbd5aed9274952116a7 (MD5) / Made available in DSpace on 2017-04-18T20:27:33Z (GMT). No. of bitstreams: 1
hernandezbaltodano_da_me_bauru.pdf: 2171039 bytes, checksum: 8f2efded7710ccbd5aed9274952116a7 (MD5)
Previous issue date: 2017-03-15 / Outra / Considerando as amplas aplicações de materiais compósitos para melhorar estruturas de obras em engenharia, é importante estudar a dependência do comportamento do material em função da velocidade de deformação aplicada aos materiais compósitos e aos epóxis adesivos. Propriedades mecânicas do material Sikacarbodur S512 e materiais adesivos mostram comportamentos diferentes quando analisados utilizando diferentes razões de deformação. Os resultados obtidos mostram que o Sikacarbodur S512 não é um material dúctil devido à ausência de capacidade de experimentar deformações inelásticas porque o domínio elástico domina seu comportamento mecânico. Os aditivos epóxis não têm domínio plástico considerável, e o intervalo visco elástico domina o seu comportamento mecânico sob forças de tração. As análises de microscopia eletrônica de varredura (MEV) das amostras de Sikacarbodur S512 mostram que o comportamento de fratura acontece na zona de interface (zona de contato entre as fibras e a resina) que é afetada pela concentração de tensões e propagações de trincas. As análises de MEV antes e depois dos testes de tração das amostras de Sikadur 30 e Sikadur 330 mostram que ambos os materiais possuem uma fase contínua e uma fase granular. Nas duas resinas as ligações covalentes são quebradas durante os testes embora o Sikadur 30 tem o comportamento mais crítico. O Sikadur 330 tem melhor comportamento mecânico do que o sikadur 30 e esse melhor comportamento é mais bem entendido quando compara-se suas deformações de ruptura em tensão e suas capacidades para absorver energia. / Considering the wide application range of composite materials for retrofitting civil engineering structures, it is found important to study the strain rate dependent behavior of both composite materials and some structural adhesive epoxies. Mechanical properties of Sikacarbodur S512 and adhesives bonding materials show different behavior when analyzed at different strain rates. Moreover, it was found that Sikacarbodur S512 is not a ductile material since it cannot sustain inelastic deformation because an elastic range governs its mechanical behavior. Epoxies adhesive do not have a significant plastic range; a viscoelastic range governs their main mechanical behavior under tensile loads. Sikacarbodur S512 analyses using scanning electron microscopy (SEM) shows that the fracture behavior is addressed by the interphase zone (contact zone between fiber and resin) which is affected by tensile stress concentration and cracks propagations. SEM analyses before and after tensile tests of both Sikadur 30 and Sikadur 330 shows that they have a continuous phase and a granular phase. In both resins, covalent bonds are broken, however sikadur 30 shows the most critical behavior. Sikadur 330 has better mechanical behavior under uniaxial tensile test than sikadur 30, and this better behavior is realized when their tensile strain to break and absorbed energy capacity are compared.
|
197 |
Análise da microfenda axial em cavidades classe V restauradas com resina composta e polimerizadas com diferentes fontes de luz. Estudo pela microscopia eletrônica de varredura /Magnani, Cristina. January 2002 (has links)
Resumo: Um dos maiores problemas das restaurações de resinas compostas é a sua contração durante a polimerização, causando fendas entre as paredes cavitárias e o material restaurador. Assim, este trabalho teve como objetivo avaliar a influência da fonte de luz polimerizadora na formação de fendas axiais em restaurações classe V de dois tipos de resina composta. Foram utilizados 80 molares humanos, nos quais foram realizados os preparos cavitários com: 2mm de profundidade, 2mm de extensão ocluso-cervical e 2mm de extensão mésio-distal. Foram confeccionadas duas restaurações em cada dente (uma na superfície vestibular e outra na lingual) restauradas com dois tipos de resinas compostas: micropartículas (Filtek A110, cor A3 - 3M) e híbrida (Filtek P60, cor A3 - 3M); utilizando o sistema adesivo Prime & Bond NT (Dentisply), para um total de 160 amostras. Essas amostras foram divididas em 8 grupos, variando-se a fonte de luz e o tempo utilizado para a fotopolimerização do material: Grupo 1: resina micropartículas + aparelho convencional - 40s; Grupo 2: resina híbrida + aparelho convencional - 40s; Grupo 3: resina micropartículas + laser de argônio - 20s; Grupo 4: resina híbrida + laser de argônio - 20s; Grupo 5: resina micropartículas + diodo emissor de Luz (LED) azul- 40s; Grupo 6: resina híbrida + LED azul- 40s; Grupo 7: resina micropartículas + LED azul- 60s; Grupo 8: resina híbrida + LED azul- 60s. Os dentes foram armazenados em água destilada por 7 dias e submetidos à ciclagem térmica. A análise das medidas de fenda, quando presente, foi realizada através de microscopia eletrônica de varredura pela técnica de réplica, e os resultados obtidos foram submetidos a análise estatística de variância e teste de Tukey ao nível de 5% de significância. Concluiu-se que a resina de micropartículas apresenta maior contração de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: One of the greatest problems of restorations with composite resin is its contraction during light-curing, casing gaps between the cavitary walls and the restorative material. Thus, this study had as main goal to evaluate the influence of the light source light-cured on the formation of axial gaps in class V restorations of two types of composite resin. Eighty (80) human molars were used, in which cavitary preparations were accomplished with: 2mm of depth, 2mm of occlusocervical extension and 2mm of mesiodistal extension. Two restorations in each tooth were restored (one in the vestibular surface and the other on the lingual surface) with two types of composite resin: microparticles (Filtek A110, color A3 - 3M) and hybrid (Filtek P60, color A3 - 3M); using the adhesive system Prime & Bond NT (Dentisply), on a total of 160 samples. These samples were divided into eight groups, varying the light source and the time used for the material light-curing: Group 1: microparticles resin + conventional appliance - 40 s; Group 2: hybrid resin + conventional appliance - 40 s; Group 3: microparticles resin + argon laser - 20 s; Group 4: hybrid resin + argon laser - 20 s; Group 5: microparticle resin + light emitting diodes (LEDs) blue - 40 s; Group 6: hybrid resin + blue LEDs - 40 s; Group 7: microparticles resin + blue LEDs - 60 s; Group 8: hybrid resin + blue LEDs - 60 s. All teeth were storage in distilled water for 7 days and submitted to thermal cycling. The analysis of the gap measures, when present, was fulfilled by using the scanning electron microscope by the reproduction technique, and the results obtained were submitted to the statistical analysis of variance and the Tukey test to 5% significance level. It was concluded that the microparticles resin presents more light-curing contraction than the hybrid resin, independently... (Complete abstract, click electronic address below). / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Vanderlei Salvador Bagnato / Banca: Osmir Batista de Oliveira Júnior / Banca: Alberto Magno Gonçalves / Mestre
|
198 |
Identificação de Neutrophil Extracellular Traps em lesões tegumentares de pacientes com Paracoccidiodomicose e análise da formação de NETs in vitro por neutrófilos humanos desafiados com Paracoccidioides brasiliensis /Coletta, Amanda Manoel Della. January 2014 (has links)
Orientador: Luciana Alarcão Dias-Melicio / Banca: Angela Maria Victoriano de Campos Soares / Banca: Ronel Luciano Mamoni / Resumo: Paracocciodioidomicose (PCM) é uma micose sistêmica, causada por fungo dimórfico do gênero Paracoccidioides (Paracoccidioides brasiliensis e Paracoccidioides lutzii), sendo endêmica na América Latina. Nos últimos anos, estudos têm enfocado o papel dos neutrófilos (PMNs) na imunidade, uma vez que a literatura enfatiza o dinâmico envolvimento dessas células durante a defesa do hospedeiro contra diversos micro-organismos. Recentemente, foi demonstrado que neutrófilos podem utilizar uma nova estratégia para destruir patógenos chamada NETose, um tipo de morte celular diferente dos bem elucidados mecanismos de apoptose e necrose. Essa via envolve a liberação de redes extracelulares constituídas de conteúdo nuclear e granular por PMNs ativados. É proposto que as NETs destruam micro-organismos que não sejam fagocitados pelos neutrófilos, por possuírem tamanho ou morfologia maiores que as células, o que pode ocorrer com o Pb, uma vez que esse fungo assume essas características. Nesse contexto, os objetivos desse estudo foram identificar a presença das NETs tanto in vivo como in vitro, analisando lesões tegumentares de pacientes com PCM e culturas de PMNs do sangue periférico de pacientes e indivíduos saudáveis desafiados com diferentes cepas de P. brasiliensis. Fragmentos de biópsias foram marcados com anticorpos anti-histona (Texas-Red), anti-elastase (FITC), e corados com DAPI para avaliação por microscopia confocal, e com H&E para análise histopatológica. PMNs do sangue periférico de pacientes e indivíduos saudáveis foram isolados e desafiados com P. brasiliensis (Pb18 e Pb265) para avaliação de NETs por microscopia de varredura, microscopia confocal e quantificação dessas estruturas por Picogreen dsDNA kit. As imagens de microscopia confocal das biópsias revelaram a presença de constituintes das NETs, localização de DNA extracelular corado com DAPI, com ... / Abstract: Paracoccidiodomycosis (PCM), an endemic systemic mycosis in Latin America, is caused by the thermodimorphic fungus of Paracoccidioides genus (Paracoccidioides brasiliensis (Pb) and Paracoccidoides lutzii). Recently, works in PCM have focused the role of neutrophils (PMNs), since literature has demonstrated the dynamic involvement of these cells in host defense against microorganisms. Studies have shown that PMNs could use a novel strategy to destroy microorganisms (NETosis), a type of neutrophil death distinct from apoptosis and necrosis. This mechanism involves the release of extracellular traps by activated neutrophils, known as neutrophil extracellular traps (NETs). It has been proposed that NETs may destroy microorganisms that were not phagocytosed by neutrophils, and this could be proposed for Pb, since the fungus yeast can present different sizes. In this context, the objectives of this study were identify the presence of NETs in vivo and in vitro, analyzing samples of patients with PCM by different methodologies. Tissue sections from formalin-fixed biopsies were stained with DAPI, anti-elastase (FITC) and anti-histone (Texas-Red) for confocal immunofluorescence microscopy analysis, and with Hematoxylin-Eosin (H&E) for histopathology. Neutrophil cultures were challenged with two isolates of Pb (Pb18 and Pb265), analyzed by scanning electron microscopy and NETs were quantified by the Picogreen dsDNA kit. The images revealed the presence of NETs constituents, nuclear and extracellular localization of DNA, co-localization of elastase and histone, confirmed by the overlay of the three stains. Histopathology showed the presence of Pb and inflammatory infiltrate with high number of neutrophils on the site of the lesion and extracellular DNA (hematoxylin positive) indicating NETs. Both isolates were able to induce NET release in vitro in similar levels. Thus, P. brasiliensis (Pb18 and Pb265) is able to induce NETs formation by ... / Mestre
|
199 |
Micropartículas de goma gelana revestidas com filmes de amido resistente/pectina como estratégia para administração oral de insulina /Meneguin, Andreia Bagliotti. January 2016 (has links)
Orientador: Beatriz Stringhetti Ferreira Cury / Banca: Maria Palmira Daflon Gremião / Banca: Silvia Stanisçuaski Guterres / Banca: Marlus Chorilli / Banca: Hernane da Silva Barud / Resumo: O desenvolvimento de um sistema que possibilite a administração oral da insulina (INS) constitui um grande desafio, já que esta pode ser degradada nas porções superiores do trato gastrintestinal (TGI). Seu encapsulamento no interior de matrizes poliméricas baseadas em goma gelana (GG) deve oferecer significante proteção contra as condições adversas do TGI, além do estabelecimento de interações mucoadesivas. O revestimento de formas farmacêuticas sólidas com amido resistente tipo 3 é uma estratégia tecnológica racional para se alcançar a liberação cólon específica de fármacos. A pectina também agrega propriedades importantes nesse sentido, já que é resistente à proteases e amilases. O objetivo deste trabalho foi a obtenção e caracterização de micropartículas (MP) de GG (1,5, 2,0 ou 2,5%), reticuladas com Al3+ (3 ou 5%) e revestidas com filmes de amido resistente/pectina para a administração oral de INS. O método de obtenção empregado foi eficiente com rendimento máximo de 99,10%, além de ter possibilitado a obtenção de MP com elevada eficiência de encapsulação (máximo de 89,11%). As MP apresentaram diâmetro médio de 1012 a 1197 μm e circularidade variando de 0,68-0,81. A análise de microscopia eletrônica de varredura indicou que o aumento da concentração de GG foi responsável pela obtenção de MP mais esféricas e que a INS alterou o rearranjo das estruturas. A seção transversal mostrou um revestimento contínuo e intacto. De acordo com os dados de difração de raios-X, as MP apre... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The development of a system that enables the oral administration of insulin (INS) is a major challenge, since the INS can be degraded in the upper portions of gastrintestinal tract (GIT). Its encapsulation within polymer matrices based on gellan gum (GG) should offer significant protection against the adverse conditions of the GIT, in addition to establishing mucoadhesive interactions. The coating of solid dosage forms with type 3 resistant starch is a rational strategy to achieve the colon specific drug delivery. Pectin also adds important properties in this sense, since it is resistant to proteases and amylases. The aim of this work was to obtain and to characterize GG MP (1.5, 2.0 or 2.5%), crosslinked with Al3+ (3 or 5%) and coated with films resistant starch/pectin for the oral administration of INS. The method employed was effective with a maximum yield of 99.10%, besides having allowed the obtaining of MP with a high encapsulation efficiency (up to 89.11%). The MP showed a mean diameter from 1012 to 1197 μm and circularity ranging from 0.68 to 0.81. The scanning electron microscopy indicated that the increase of the concentration of GG is responsible for obtaining more spherical MP and that INS is responsible for changing the rearrangement structures. The cross section showed a continuous and intact coating. According to the data of X-ray diffractograms, the MP have semi-crystalline structures. The liquid uptake was lower in acid media (218-615%) than in phosphate buff... (Complete abstract click electronic access below) / Doutor
|
200 |
Micropartículas poliméricas biodegradáveis contendo cetorolaco como estratégia tecnológica para liberação controlada intra-ocular /Rossanezi, Gustavo. January 2012 (has links)
Orientador: Anselmo Gomes de Oliveira / Banca: Leticia Norma Carpentiere Rodrigues / Banca: Osvaldo de Freitas / Banca: Maria Helena Andrade Santana / Banca: Marcos Antonio Corrêa / Resumo: Neste projeto, em continuidade a projetos anteriores, temos como objetivo desenvolver micropartículas biodegradáveis contendo o anti-inflamatório não esteróide cetorolaco (CT) para administração intra-ocular. As micropartículas foram baseadas na estrutura matricial, na qual o fármaco está homogeneamente distribuído na matriz polimérica seca. A técnica de obtenção utilizada no estudo foi a secagem por o Spray drying, a qual pode proporcionar partículas homogêneas e com dimensões apropriadas para a utilização pretendida. Foram obtidas micropartículas com várias proporções fármaco:polímero para evidenciar possíveis interações entre esses componentes. Estudos anteriores permitiram-nos definir que o polímero PLGA 85:15, é o polímero mais apropriado ao tempo de liberação necessário ao uso oftalmológico do cetorolaco. As condições inicias de operação do Spray drier foram estabelecidas em estudos anteriores em nosso grupo. As micropartículas foram caracterizadas por microscopia eletrônica de varredura, pela determinação dos diâmetros médios, por Espectroscopia de Infravermelho (IV), por Análise Térmica (DSC, TG/DTG, DTA) e por Difração de Raios X (DRX). A análise quantitativa do fármaco microencapsulado ou não foi realizada por Espectroscopia UV-Vis. Finalmente, a eficiência terapêutica será verificada in vivo através de estudos de biodisponibilidade em coelhos albinos, conforme protocolos estabelecidos juntamente com as equipes de oftalmologia do Hospital de Olhos de Araraquara e do Departamento de oftalmologia da Universidade Federal de São Paulo-Unifesp. A metodologia proposta mostrou-se eficiente na preparação de micropartículas de PLGA contendo CT nas concentrações de 15%, 25%, 35% e 50%, entretanto a partir da concentração de 35% as partículas não assumem forma definida... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this project, continuing the previous projects, we aim to develop biodegradable microparticles containing the NSAID ketorolac (CT) for intraocular administration. The microparticles were based on the matrix structure, in which the drug is homogeneously distributed in the dried polymer matrix. The technique of obtaining used in this study was dried by the spray drying, which can provide the particles with homogeneous dimensions appropriate for the intended use. Microparticles were obtained with various ratios drug: polymer for evidence of possible interactions between these components. Previous studies have enabled us to establish that the PLGA 85:15 polymer, the polymer is more appropriate to the release time necessary for the ophthalmic use of ketorolac. The initial conditions of operation of the spray drier were established in previous studies in our group. The microparticles were characterized by scanning electron microscopy, by determining the average diameter by infrared spectroscopy (IR) for Thermal Analysis (DSC, TG / DTG, DTA) and X-Ray Diffraction (XRD). Quantitative analysis or microencapsulated drug has not been performed by UV-Vis spectroscopy. Finally, the therapeutic effectiveness is verified through in vivo bioavailability studies in rabbits, according to established protocols with the teams of Ophthalmology, Hospital de Olhos de Araraquara and Department of Ophthalmology, Federal University of São Paulo- UNIFESP. The proposed method was effective in the preparation of PLGA microparticles containing CT in concentrations of 15%, 25%, 35% and 50%, but at concentrations of 35% particles do not assume a defined shape, while at lower concentrations than the predominant form is spherical with a tendency to agglomerate. The average particle diameter increases as... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.0838 seconds