• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 167
  • 7
  • 7
  • 7
  • 6
  • 5
  • 2
  • 1
  • Tagged with
  • 170
  • 170
  • 101
  • 50
  • 44
  • 30
  • 29
  • 17
  • 16
  • 15
  • 14
  • 14
  • 13
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Adesão à dentina

Lopes, Guilherme Carpena January 2003 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T20:55:16Z (GMT). No. of bitstreams: 0 / O objetivo foi verificar se há diferença na capacidade de união ao substrato dentinário envelhecido quando comparado com o jovem; e, se o aumento do tempo de condicionamento poderá resultar em uma maior resistência de adesão a este substrato envelhecido, sem prejudicar a união ao substrato jovem. Foram realizados testes de resistência de união, verificação da dureza dentinária e microscopia eletrônica de varredura da interface adesiva. A dentina envelhecida condicionada por 15s obteve resistência de união estatisticamente menor que todos os outros grupos. A dureza da dentina envelhecida foi maior do que a dentina jovem. O maior conteúdo mineral na dentina envelhecida dificulta a união, resultando em mais baixa m-TBS quando o condicionamento é feito por apenas 15s. Por outro lado, a duplicação do tempo de condicionamento resulta em mais adequada adesão à dentina envelhecida alcançando médias similares à dentina jovem.
12

Batimentos quânticos dependentes do SPIN via STM

Leandro, Silvana Castro [UNESP] 28 June 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-28Bitstream added on 2014-06-13T19:07:22Z : No. of bitstreams: 1 leandro_sc_me_ilha.pdf: 1782827 bytes, checksum: 80c4f27095adfdf0cbd88b99966a75fa (MD5) / Neste trabalho investigou-se teoricamente a densidade local de estados (LDOS) sondada por uma ponta de STM de metais hospedando um átomo adsorvido e uma impureza subsuperficial. Modelamos o sistema por meio do Hamiltoniano de Anderson de duas impurezas. Utilizando-se do procedimento da equação de movimento nas funções de Green, derivamos expressões analíticas para a LDOS de dois tipos de hospedeiro: uma superfície metálica e um fio quântico. A LDOS revela oscilações de Friedel e interferência Fano como função da posição da ponta. Essas oscilações dependem fortemente da dimensão do hospedeiro. Encontramos que os números de onda de Fermi dependentes do spin dão origem a batimentos quânticos spin-polarizados na LDOS. Embora a LDOS da superfície mostre um padrão de batimentos amortecidos, ela possui um comportamento oposto no fio quântico. Devido a ausência de amortecimento, o fio opera como um filtro de spins espacialmente resolvido com elevada eficiência. / We theoretically investigate the local density of states (LDOS) probed by an STM tip of ferromagnetic metals hosting a single adatom and a subsurface impurity. We model the system via the two-impurity Anderson Hamiltonian. By using the equation of motion with the relevant Green’s functions, we derive analytical expressions for the LDOS of two host types: a surface and a quantum wire. The LDOS reveals Friedel-like oscillations and Fano interference as a function of the STM tip position. These oscillations strongly depend on the host dimension. Interestingly, we find that the spin-dependent Fermi wave numbers of the hosts give rise to spin-polarized quantum beats in the LDOS. Although the LDOS for the metallic surface shows a damped beating pattern, it exhibits the opposite behavior in the quantum wire. Due to this absence of damping, the wire operates as a spatially resolved spin filter with a high efficiency.
13

Avaliação da resistência de união ao cisalhamento, de diferentes sistemas adesivos à dentina. Análise em MEV do infiltrado resinoso

Quagliatto, Paulo Sérgio [UNESP] 10 December 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-12-10Bitstream added on 2014-06-13T19:20:27Z : No. of bitstreams: 1 quagliatto_ps_dr_arafo.pdf: 1690792 bytes, checksum: c0676d0303727f92ee07518d6edd37d9 (MD5) / Foi avaliada in vitroa resistência de união ao cisalhamento de seis sistemas adesivos à dentina, e também, análise microscópica (MEV) do infiltrado resinoso.Para tanto, noventa terceiros molares humanos, hígidos e erupcionados foram selecionados, sendo setenta e dois utilizados para os testes mecânicos e dezoito para análise microscópica.Inicialmente setenta e dois molares tiveram suas superfícies oclusais desgastadas, até completa eliminação do esmalte e total exposição da área dentinária, sendo incluídos em matriz bi-partida com gesso especial. Após a superfície dentinária ter sido submetida a ação de lixas d'água de granulação decrescente, os corpos de prova (doze por grupo) receberam de acordo com as recomendações dos fabricantes, a aplicação dos sitemas adesivos dentinários: G1-SE BOND; G2- ABF BOND; G3- PRIME & BOND NT; G4- SINGLE-BOND;G5-TENURE QUICK FLUORIDE e G6-GLUMA CONFORT BOND DESSENSITIZER; sendo posteriormente acoplados em Aparatus Ultradent que possue uma matriz de teflon com diâmetro de 2,35 mm de raio onde uma resina composta (P60-3M Dental Produc.) foi compactada pelo orifício da matriz e fotopolimerizada seguindo o protocolo do fabricante. Obteve-se assim um cilindro de resina composta que manteve-se aderido a superfície dentinária. Os corpos de prova foram submetidos a termociclagem (500x,5-55°C) , armazenados em água destilada a 37°C por 48 horas e fixados em máquina de ensaio universal Instron/MTS para os testes de cisalhamento.Os valores médios de resistência de união, em Mpa, para os grupos foram: G1 -22.9 l 4.3; G2 -23.9 l 3.2; G3 -18.0 l 2.2; G4 -25.0 l 4.9; G5 -23.5 l 4.7 e G6 -22.7 l 3.2. ANOVA, a nível de significância p<0.05, apresentou diferenças significantes. SNK para comparação entre os grupos mostrou diferenças significantes entre os grupos, 1 vs 3, 2 vs 3, 4... . / To evaluate the resin-dentin interfacial morphology and shear bond strength to dentin of several new self-etching primers and experimental dentin bonding systems and one-bottle enamel-dentin adhesives. Seventy-two healthy human molars were selected. Flat occlusal surfaces were made with a series of SiC paper into the superficial-to-middle dentin. The following groups were established (12 teeth per group): (G1) SE Bond; (G2) Experimental ABF Bond; (G3) Prime & Bond NT; (G4) Single-Bond; (G5) Tenure Quick F and (G6) Gluma Comfort Bond + Desensitizer. For all groups P60 (3M) resin-based composite was used. All adhesives were handled according to the manufacturers' instructions. Immediately after bonding, the specimens were stored in water for 48 hrs and then thermocycled (500x, 5-55°C). Specimens were sheared at a crosshead speed of 1 mm/min in an Instron / MTS machine. The results were analyzed with an ANOVA and Student-Newman-Keuls (SNK) test. All samples were treated with glutaraldehyde, 37% phosphoric acid, NaOCl, HCL, and gold-palladium to be inspected under SEM (Model 840A, JEOL). In MPa: (1) 22.9 l 4.3; (2) 23.9 l 3.1; (3) 18.0 l 2.2; (4) 25.0 l 4.9; (5) 23.5 l 4.7;(G6) 22.7 l 3.2. ANOVA showed a statistically significant difference (P< 0.05) among the groups. SNK test showed that groups 1 vs 3, 2 vs 3, 4 vs 3, 5 vs 3 and 6 vs 3 were statistically significantly different (P<0.05). SE Bond, Experimental ABF Bond, Single-Bond, Tenure Quick F and Gluma Comfort Bond + Desensitizer showed no significant differences among them, but were different from Prime-Bond NT. All adhesives systems produced resin-infiltrated dentin layer within intertubular dentin of resin tags by SEM. Bond strength did not correlate well with the thickness and morphology of resin-infiltrated dentin layer.
14

Estudo de cerâmicas de SiC e Al2O3 tratadas por expansor de plasma de nitrogênio

Santos, Carlos do Nascimento [UNESP] 31 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-31Bitstream added on 2014-06-13T18:44:19Z : No. of bitstreams: 1 santos_cn_dr_guara_prot.pdf: 4826848 bytes, checksum: 60065e84db65f86f5e284861f7afaf69 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Hoje em dia a proteção de veículos, aeronaves e pessoas está aumentando mundialmente e em muitos campos de aplicação diferentes, tais como em cobertura estrutural, armadura balística, cobertura térmic, substrato de espelho de alto desempenho, entre outras. Alguns dos principais materiais cerâmicos empregados tem sido o SiCe o Al2O3. A técnica de aplicação de plasma sobre a superfície de cerâmicas SiC e Al2O3 é relativamente recente e pode promover relevantes modificações superficiais. Uma nova técnica de plasma para tratamento superficial de cerâmicas densas de SiC e Al2O3, baseada na técnica Z-pinch inverso e denominada de expansor de plasma, utilizando plasma de nitrogênio reativo, foi usada neste trabalho. Este tipo de plasma pode simular determinadas condições as quais os materiais cerâmicos são submetidos quando da reentrada na atmosfera terrestre. Cerâmica de SiC e Al2O3 foram sinterizadas em 1950ºC e 1600ºC, respectivamente, após prensagem uniaxial e isostática. Para produção das cerâmicas de SiC foi utilizado como aditivo o YAG nas proporções de 5%, 7,6% e 10%, enquanto o Al2O3, utilizou como aditivo o MgO. Todos os conjuntos de amostras passaram pelos processos de lixamento e polimento superficial. Durante o tratamento superficial por plasma, das faces polidas ou conjuntos de amostras de SiC em média 1440 pulsos de descargas, enquanto os conjuntos de amostras de Al2O3, foram divididos em três grupos igualmente separados e receberam em média 700, 1000 e 1480 descargas, respectivamente. Todas as descargas foram feitas em intervalos iguais de 20 minutos.Esta técnica inovadoa de plasma promoveu modificações nas superfícies das cerâmicas. As propriedades superficiais morfológicas e mecânicas das cerâmicas de Al2O3, após o ataque de plasma, sofreram menores... / Nowadays protection of vehicles, aircraft andpeople is increasing worldwide in many different application fields, sucha as, the structural coating, ballistic armor, thermal coating, high performance mirror substrate, among other things. Some of the main ceramics materials like SiC and Al2O3 have beem employed. The plasma treatment of the SiC and Al2O3 ceramics surface is relatively recent technique applied and it is able to promote relevant superficial modifications. A novel plasma techique for surface treatment of high density ceramics such as SiC and Al2O3 is based on the reverse Z-pinch also called plasma expander and uses nitrogen as working gas. This plasma type can simulate certain conditions which the ceramic materials are submitted when of the reentry into Earth's atmosphere. The SiC and Al2O3 ceramics were sintered at 1950 °C and 1600 °C respectively using uniaxial and isostatic pressing method. The SiC ceramics were produced with additive YAG with proportions of 5%,7,6% and 10%, on the other hand, the Al2O3, ceramics were produced with additive MgO in its liquid phase. All samples have undergone the same processes of samples surface sanding and polishing. During the surface treatment by plasma performed on the polished faces, the sets of SiC samples received an average of 1440 plasma pulses, while the series of Al2O3 samples, were divided equally into three gropus and received and average of 700, 1000 and 1440 plasma pulses, respectively. All discharges were made at equal intervals of 20 minutes. The innovative plasma technique produced changes in the surfaces of ceramics and the morphological and mechanical surfaces of Al2O3 suffered smaller alterations after the plasma attack than the ones of SiC. from... (Complete abstract click electronic access below)
15

Etiologia, progressão e tratamento das peri-implantites

Shibli, Jamil Awad [UNESP] 24 March 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-03-24Bitstream added on 2014-06-13T20:08:48Z : No. of bitstreams: 1 shibli_ja_dr_arafo.pdf: 1695083 bytes, checksum: 3338c6c93a1d7714402de61c6827df6c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
16

Biodegradação de filmes de polietileno de baixa densidade (PEBD), polihidroxibutirato-co-hidroxivalerato (PHBV) e blenda de PEBD/PHBV (70/30), em coluna de solo

Bucioli, Elaine Cristina [UNESP] 03 April 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-03Bitstream added on 2014-11-10T11:58:38Z : No. of bitstreams: 1 000789456.pdf: 4124788 bytes, checksum: 893ba3b360feb1b81ce417904c8dde18 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os plásticos são materiais que possuem larga escala de aplicação industrial e trazem importância econômica para sociedade atual. O uso dos plásticos sintéticos em embalagens e produtos descartáveis gera impactos sócio-ambientais devido ao descarte e disposição inadequada deste material. Uma das alternativas para minimizar esses impactos é a produção de blendas que possuam características próprias ao uso e que após a utilização, sejam absorvidas em um período curto de tempo pelo meio ambiente. Esse trabalho avaliou a biodegradação dos filmes de PHBV (poli(hidroxibutirato-co-hidroxivalerato)), dos filmes de PEBD (polietileno de baixa densidade) e da blenda de PEBD/PHBV (70/30), em coluna de solo, utilizando metodologias como: Microscopia Eletrônica de Varredura (MEV), Infravermelho com Transformada de Fourier (FTIR) e avaliação da perda de massa. Foi observado que o PHBV se biodegradou em 30 dias de exposição ao solo, período menor de exposição comparado ao PEBD e a blenda, 180 dias. Através do MEV foi possível observar mudanças micro morfológicas significativas na superfície dos filmes de PHBV e da blenda (furos, fraturas, descamações e erosões), o que complementa os valores encontrados de perda de massa, em que o PHBV teve uma redução de 43,9% e a blenda uma redução de 15,7%, nos respectivos períodos do processo biodegradativo. Os espectros de FTIR forneceram informações importantes para avaliação da biodegradação, pois foram capazes de mostrar as alterações estruturais relevantes após o processo biodegradativo, tal como a hidrólise de ésteres do PHBV na interfase entre o PEBD e PHBV. Através das análises de FTIR verificou se alteração de cristalinidade dos materiais poliméricos, que foi um indicativo que auxiliou a avaliação da biodegradação dos filmes. A blenda nessa proporção (70:30), demonstrou ser susceptível à comunidade microbiana do solo, sofrendo mudanças significativas... / Plastics are materials with large-scale industrial application and economic importance to modern society. The use of synthetic plastics in packaging and disposable products generates socio- environmental due to improper disposal and disposal of this material impacts . One alternative to minimize these effects is the production of blends which have their own characteristics and use after use, to be absorbed in a short period of time in the environment . This study evaluated the biodegradation of PHBV films (poly ( hydroxybutyrate-co- hydroxyvalerate ) ) , films of LDPE ( low density polyethylene ) and LDPE blend / PHBV ( 70/30 ) in the soil column using methodologies as: Scanning Electron Microscopy (SEM ) , Fourier Transform Infrared ( FTIR ) and weight loss evaluation. PHBV was biodegraded within 30 days of exposure to the soil , the less exposure time compared to LDPE and blends in 180 days . Through SEM we observed significant micro morphological changes on the surface of PHBV and blend films ( holes , fractures , desquamation and erosions ) , which complements the values found of mass loss , where the PHBV decreased by 43.9 % and the blend showed a reduction of 15.7% in the respective periods of the biodegradation process. The FTIR spectra provide important information for assessing biodegradation because they showed the important structural changes after the biodegradation process , such as hydrolysis of esters of PHBV at the interface between LDPE and PHBV . Using FTIR analysis was verified crystallinity change of the polymer materials, which was an indication of the films biodegradation. The blend in this ratio, shown to be susceptible to the soil microbial community, undergoing significant changes in its morphology
17

Efeito do estádio do ciclo estral e adição de hormônios ao meio de cultivo in vitro sobre a morfologia do complexo cumulus-oócito canino /

Pires-Buttler, Eliandra Antonia. January 2010 (has links)
Orientador: Wilter Ricardo Russiano Vicente / Banca: Maria Denise Lopes / Banca: Ana Paula Coelho Ribeiro / Banca: Laura Satiko Okada Nakaghi / Banca: Idércio Luíz Sinhorini / Resumo: Este estudo foi desenvolvido com o intuito de avaliar comparativamente o efeito do estádio do ciclo estral, bem como a adição de hormônios aos meios de cultivo in vitro sobre a morfologia do complexo cumulus-oócito canino. Os oócitos foram coletados de 30 cadelas hígidas submetidas à ovariosalpingo-histerectomia, divididas em dois grupos de acordo com a condição reprodutiva (fase folicular e anestro). A avaliação foi feita por microscopia eletrônica de varredura e transmissão, antes e após o período de cultivo in vitro por 72h em dois diferentes meios: meio controle - A (TCM199) e meio B: TCM199 adicionado de 10UI/mL de LH, 2μg/mL de progesterona (P4) e 2μg/mL de Estradiol(E2). Os resultados revelaram que o diâmetro oocitário não é influenciado pela fase reprodutiva, assim como a comunicação intercelular, e os aspectos morfológicos relacionados à forma e arranjo das células do cumulus, in vivo. A fase do ciclo estral exerceu influência sobre a morfologia do complexo cumulus-oócito, de tal forma que oócitos pertencentes ao grupo folicular apresentaram-se com maior grau de maturidade nuclear e citoplasmática do que oócitos do grupo do anestro. A suplementação hormonal afetou positivamente a maturação nuclear, mas não exerceu efeito sobre a maturação citoplasmática. Com relação à ultra-estrutura a presença de hormônios nos meios de cultivo foi benéficas tanto para a comunicação entre as células do cumulus como para a manutenção da integridade oocitária / Abstract: This study was developed in order to comparatively evaluate the effects of stages of the estrous cycle, as well as the addition of hormones to culture media in vitro on the morphology of cumulus-oocyte complex canine. The oocytes were collected from 30 healthy bitches ovariosalpingo underwent hysterectomy were divided into two groups according to reproductive condition (follicular phase and anestrus). The evaluation was performed by scanning electron microscopy and transmission, before and after cultivation in vitro for 72h in two different media: control medium - A (TCM199) and medium B: TCM199 added 10IU/mL LH, 2μg / mL progesterone (P4) and 2μg/mL Estradiol (E2). The results revealed that the oocyte diameter is not influenced by reproductive stage, as well as intercellular communication, and morphological aspects related to the shape and arrangement of cumulus cells, in vivo. The estrous cycle phase influenced the morphology of cumulus-oocyte complex, such that follicular oocytes in the group presented with greater maturity than nuclear and cytoplasmic oocyte group of anestrus. The hormonal supplementation positively affected nuclear maturation, but had no effect on cytoplasmic maturation. Regarding the ultrastructural presence of hormones in culture media was beneficial both for communication between the cumulus cells as well as preserving the integrity of oocyte / Doutor
18

Avaliação da qualidade do reparo ósseo em ratas ovariectomizadas, lesionadas e tratadas com Arnica montana fitoterápica e homeopática

Silva, Edmundo da [UNESP] 13 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-13Bitstream added on 2014-06-13T19:57:08Z : No. of bitstreams: 1 silva_e_me_sjc.pdf: 1226838 bytes, checksum: da62f234ce03abaad7d5e8637ae95e44 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dados estatísticos nacionais e mundiais demonstram que o número de indivíduos idosos tende a crescer de maneira exponencial nos próximos anos, tornando-se uma população significantemente e proporcionalmente maior que as demais. Entre as doenças mais comuns nesta faixa etária encontra-se a osteoporose, doença que reduz a massa esquelética e deteriora a microarquitetura do osso causando fragilidade e aumentando o risco de fraturas. Este estudo teve como proposta avaliar o efeito da Arnica montana fitoterápica e homeopática no reparo de lesões ósseas, visando uma possível forma de tratamento de fraturas na vigência de osteoporose. Os ensaios experimentais foram realizados em ratas Wistar adultas, divididas em quatro grupos: ovariectomizado tratado com Arnica montana 6CH (OVZ 6CH); ovariectomizado tratado com Arnica montana tintura mãe (OVZ TM); ovariectomizado tratado com placebo (OVZ PL) e animais com falsa cirurgia de ovariectomia e tratado com placebo (Sham PL). Após 45 dias da cirurgia sham ou de ovariectomia, foi realizada uma lesão óssea monocortical na tíbia de todos os animais e iniciados os respectivos tratamentos. Os animais foram eutanasiados após, 6, 12, 18 e 28 dias e as tíbias retiradas para avaliação das suas dimensões e análise do reparo ósseo através de densidade óssea radiográfica, ensaios biomecânicos e microscopia eletrônica de varredura (MEV). Os dados foram submetidos à análise estatística pelos testes de ANOVA e Tukey (p<5%). Demonstraram que o tratamento com arnica 6CH foi melhor que o com arnica TM quanto à resistência e à qualidade da regeneração óssea, enquanto a TM mostrou melhor valor de densidade óptica / National and international data show that in the next years the elder population tends to have an exponential increase becoming to be significantly higher than the other age population. Among the frequent diseases in the elderly is osteoporosis, a disease that decreases bone mass and deteriorates bone structure causing fragility and a high risk of fracture. The aim of this study was to evaluate the effect of phytotherapic and homeopathic Arnica montana on bone repair quality, aiming its possible use in the treatment of bone fracture in patients with osteoporosis. This experimental study was realized in Wistar adult female rats divided in 4 groups according to the following treatments: ovariectomized treated with Arnica montana 6CH (OVZ 6CH); ovariectomized treated with extract of Arnica montana (OVZ TM); ovariectomized with false treatment with placebo (OVZ PL) and rats with sham surgery and false treatment with placebo (Sham PL). In a period of 45 days after ovariectomy or sham surgery all animals were drilled a monocortical lesion in their tibiae and began the proposed treatments. They were euthanized after 6, 12, 18 e 28 days and had the tibiae removed to evaluation of tibiae dimensions and bone repair by radiographic density, biomechanical test and electronic scan microscopy (MEV). Data were analyzed by ANOVA e Tukey tests (p<5%). The results showed that treatment with arnica 6CH was better than with arnica TM considering bone resistance to biomechanical flection and bone repair quality, while arnica TM showed better bone density values
19

Biomodificação radicular em dentes expostos e não expostos à placa bacteriana

Fontanari, Lucas Amaral [UNESP] 18 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-18Bitstream added on 2014-06-13T20:36:50Z : No. of bitstreams: 1 fontanari_la_me_arafo.pdf: 1048250 bytes, checksum: a30d89a53a7dc0062a5544433078f318 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O fator etiológico principal da doença periodontal é a placa bacteriana e a raspagem e o alisamento radicular é o tratamento utilizado para removê-lo, mas, além de não promover total descontaminação forma smear layer que pode funcionar com uma barreira física ao restabelecimento de uma nova inserção conjuntiva, atrasando ou até impedindo a regeneração dos tecidos periodontais. O condicionamento radicular com diferentes agentes químicos visa remover a smear layer e expor fibras colágenas da superfície radicular promovendo uma descontaminação adicional à raiz, favorecendo o processo de reparação do periodonto. Apesar de alguns estudos in vitro apresentarem resultados favoráveis à realização do condicionamento radicular, estudos in vivo apresentam resultados controversos. Estes resultados conflitantes podem ser atribuídos a diversos fatores e provavelmente o grau de hipermineralização do dente seja um dos mais importantes fatores. Assim, este estudo avaliou o condicionamento radicular com diferentes agentes (ácido cítrico 25% e 1%, EDTA 24%, cloridrato de tetraciclina 50mg/ml e solução salina) em espécimes de dentes com cálculo visível (expostos à placa bacteriana) e dentes inclusos (não expostos à placa bacteriana). Após tramitação laboratorial de rotina os espécimes foram fotografados em microscopia eletrônica de varredura. Um examinador treinado, calibrado e cego avaliou as fotomicrografias obtidas utilizando o Índice de Remoção de Smear Layer. A análise estatística (teste Mann Whitney) foi realizada comparando-se a freqüência dos escores obtidos, e mostrou que houve uma tendência a dentes não expostos à placa bacteriana apresentarem 15 maior facilidade de remoção de smear layer (desmineralização), quando comparados a dentes expostos à placa bacteriana / The main etiological factor of periodontal disease is dental plaque and scaling, and root planning is the treatment used to remove it. This treatment doesn’t promote total decontamination and it forms smear layer which can work as a physical barrier to establish a new connective insertion, delaying or even preventing the regeneration of periodontal tissues. The root conditioning with different chemical agents aims to remove the smear layer and expose collagen fibers on the root surface promoting additional root decontamination, thus resulting in the periodontal repair. Although some in vitro studies produce favorable results to perform of root conditioning, in vivo studies are controversial. These conflicting results may be attributed to several factors and the degree of tooth hypermineralization is probably one of the most important factors. Thus, this study examined the root conditioning with different agents (25% and 1% citric acid, 24% EDTA, 50 mg/ml tetracycline hydrochloride and saline solution) in tooth specimens with visible calculus (exposed to dental plaque) and impacted teeth (not exposed to plaque). After routine laboratory performance, specimens were photographed in scanning electron microscopy. A trained examiner, blinded and calibrated, evaluated the photomicrographs by the Index of smear layer removal. Statistical analysis (Mann Whitney test) was performed to compare the score frequency, and showed that teeth not exposed to dental plaque presented easier of smear layer removal (demineralization) when compared to teeth exposed to dental plaque
20

Biodegradação de filmes de polietileno de baixa densidade (PEBD), polihidroxibutirato-co-hidroxivalerato (PHBV) e blenda de PEBD/PHBV (70/30), em coluna de solo /

Bucioli, Elaine Cristina. January 2014 (has links)
Orientador: José Carlos Marconato / Coorientador: Suely Patrícia Costa Gonçalves / Banca: Sandra Mara Martins Franchetti / Banca: Adriana de Campos / Resumo: Os plásticos são materiais que possuem larga escala de aplicação industrial e trazem importância econômica para sociedade atual. O uso dos plásticos sintéticos em embalagens e produtos descartáveis gera impactos sócio-ambientais devido ao descarte e disposição inadequada deste material. Uma das alternativas para minimizar esses impactos é a produção de blendas que possuam características próprias ao uso e que após a utilização, sejam absorvidas em um período curto de tempo pelo meio ambiente. Esse trabalho avaliou a biodegradação dos filmes de PHBV (poli(hidroxibutirato-co-hidroxivalerato)), dos filmes de PEBD (polietileno de baixa densidade) e da blenda de PEBD/PHBV (70/30), em coluna de solo, utilizando metodologias como: Microscopia Eletrônica de Varredura (MEV), Infravermelho com Transformada de Fourier (FTIR) e avaliação da perda de massa. Foi observado que o PHBV se biodegradou em 30 dias de exposição ao solo, período menor de exposição comparado ao PEBD e a blenda, 180 dias. Através do MEV foi possível observar mudanças micro morfológicas significativas na superfície dos filmes de PHBV e da blenda (furos, fraturas, descamações e erosões), o que complementa os valores encontrados de perda de massa, em que o PHBV teve uma redução de 43,9% e a blenda uma redução de 15,7%, nos respectivos períodos do processo biodegradativo. Os espectros de FTIR forneceram informações importantes para avaliação da biodegradação, pois foram capazes de mostrar as alterações estruturais relevantes após o processo biodegradativo, tal como a hidrólise de ésteres do PHBV na interfase entre o PEBD e PHBV. Através das análises de FTIR verificou se alteração de cristalinidade dos materiais poliméricos, que foi um indicativo que auxiliou a avaliação da biodegradação dos filmes. A blenda nessa proporção (70:30), demonstrou ser susceptível à comunidade microbiana do solo, sofrendo mudanças significativas... / Abstract: Plastics are materials with large-scale industrial application and economic importance to modern society. The use of synthetic plastics in packaging and disposable products generates socio- environmental due to improper disposal and disposal of this material impacts . One alternative to minimize these effects is the production of blends which have their own characteristics and use after use, to be absorbed in a short period of time in the environment . This study evaluated the biodegradation of PHBV films (poly ( hydroxybutyrate-co- hydroxyvalerate ) ) , films of LDPE ( low density polyethylene ) and LDPE blend / PHBV ( 70/30 ) in the soil column using methodologies as: Scanning Electron Microscopy (SEM ) , Fourier Transform Infrared ( FTIR ) and weight loss evaluation. PHBV was biodegraded within 30 days of exposure to the soil , the less exposure time compared to LDPE and blends in 180 days . Through SEM we observed significant micro morphological changes on the surface of PHBV and blend films ( holes , fractures , desquamation and erosions ) , which complements the values found of mass loss , where the PHBV decreased by 43.9 % and the blend showed a reduction of 15.7% in the respective periods of the biodegradation process. The FTIR spectra provide important information for assessing biodegradation because they showed the important structural changes after the biodegradation process , such as hydrolysis of esters of PHBV at the interface between LDPE and PHBV . Using FTIR analysis was verified crystallinity change of the polymer materials, which was an indication of the films biodegradation. The blend in this ratio, shown to be susceptible to the soil microbial community, undergoing significant changes in its morphology / Mestre

Page generated in 0.1211 seconds