• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo das amostras endoteliais de microscopia especular de córnea / Uso do programa "Cells Analyser" no estudo comparativo entre imagens do endotélio de córnea obtidas por microscopia especular

Melo, Cinthia Mendonça de 15 June 2007 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2007. / Submitted by Elna Araújo (elna@bce.unb.br) on 2011-06-03T20:12:52Z No. of bitstreams: 1 2007_CinthiaMendoncadeMelo.pdf: 3056825 bytes, checksum: 831f7d02f6e1fd361e0ab5f53dd1d32f (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2011-06-03T20:18:50Z (GMT) No. of bitstreams: 1 2007_CinthiaMendoncadeMelo.pdf: 3056825 bytes, checksum: 831f7d02f6e1fd361e0ab5f53dd1d32f (MD5) / Made available in DSpace on 2011-06-03T20:18:50Z (GMT). No. of bitstreams: 1 2007_CinthiaMendoncadeMelo.pdf: 3056825 bytes, checksum: 831f7d02f6e1fd361e0ab5f53dd1d32f (MD5) / Objetivo: Determinar se existe diferença entre os resultados da semiologia endotelial corneal, empregada na microscopia especular, que considera a amostra endotelial contida em uma única imagem, e a obtida quando a amostragem é orientada por software específico, em tantas imagens e células quanto indicadas por este software. Métodos: Foi realizado um estudo transversal, comparando as amostras endoteliais com e sem a intervenção do software. A amostra foi composta de 298 olhos de 149 pacientes, divididos em dois grupos: Grupo 1: composto pelos dados amostrais dos exames considerados corretos pelo software Cells Analyzer PAT. REC com 1 imagens e Grupo 2 que foi subdividido em 2 grupos- Grupo 2 A: composto pelos dados amostrais da primeira imagem dos exames considerados incorretos pelo software Cells Analyzer PAT. REC; e - Grupo 2 B: composto pelos dados amostrais dos exames que consideram tantas imagens quantas necessárias para que o exame seja considerado completo pela análise do software Cells Analyzer PAT. REC.. Foram realizadas três tipos de comparação : comparação 1: Grupo 1 X Grupo 2 A; comparação 2- Grupo 2 A X Grupo 2 B e comparação 3 - Grupo 1 X Grupo 2 B. Resultados: As três comparações demonstraram que os grupos apresentam perfis amostrais distintos, porém, dentro dos grupos estudados - Grupo 1, Grupo 2 A e Grupo 2 B - existe um perfil de homogeneidade amostral evidenciado pelo resultado da análise estatística empregada a partir de dados amostrais calculados pelo Cells Analyzer PAT. REC na amostra composta pelos 298 exames endoteliais estudados. Conclusão: O estudo dos dados amostrais sem e com a intervenção do software Cells Analyser PAT. REC se mostrou estatisticamente diferente, com amostras maiores e erros amostrais menores, o que evidencia a importância do seu uso para se obter exames de microscopia especular de córnea com representatibilidade, padronização e reprodutibilidade. _______________________________________________________________________________ ABSTRACT / Purpose: To describe differences among number of cells, evaluated endothelial area and relative error comparing endothelial samples from one endothelial image with endothelial samples obtained from guidance of a specific software, with number of cells and images as many as necessary. Methods: A transversal study was performed, comparing the endothelial samples with and without intervention of the software. The sample consisted of 298 eyes of 149 individuals. The sample was divided in two groups: group 1: data from 141 eyes considerate correct with one image; group 2: in 157 eyes was necessary to get more than one image for the sample be admited as correct; the group 2 was further divided into two subgroups: 2.A: the data of the first image and group 2. B: data of complete sample. Three comparasions were perfomed: comparation 1: Group 1 x Group 2 A; comparation 2: 2AX 2 B and comparation 3: Group A X group 2. B. Results: The statistic comparations of sample’s data (number of counting cells, evaluate field, and relative error) of the Group 1 X group 2 A, Groups 2 A X 2 B and Group A X group 2 B; showed that groups had different sample. Conclusion: The study of sample’s data with or without the analysis of the software Cells Analyzer PAT. REC showed statistically significant differences showing clearly the importance of using it in order to obtain representative, standardized and reproducible specular microscopy exam.
2

Estudos das amostras endoteliais de microscopia especular de córnea

Melo, Cinthia Mendonça de 15 June 2007 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2007. / Submitted by Rosane Cossich Furtado (rosanecossich@gmail.com) on 2010-01-04T17:56:06Z No. of bitstreams: 1 2007_CinthiaMendoncadeMelo.pdf: 3056980 bytes, checksum: 461dbf24221386dae7dc90e704dbbfa9 (MD5) / Approved for entry into archive by Carolina Campos(carolinacamposmaia@gmail.com) on 2010-01-05T17:27:16Z (GMT) No. of bitstreams: 1 2007_CinthiaMendoncadeMelo.pdf: 3056980 bytes, checksum: 461dbf24221386dae7dc90e704dbbfa9 (MD5) / Made available in DSpace on 2010-01-05T17:27:16Z (GMT). No. of bitstreams: 1 2007_CinthiaMendoncadeMelo.pdf: 3056980 bytes, checksum: 461dbf24221386dae7dc90e704dbbfa9 (MD5) Previous issue date: 2007-06-15 / Objetivo: Determinar se existe diferença entre os resultados da semiologia endotelial corneal, empregada na microscopia especular, que considera a amostra endotelial contida em uma única imagem, e a obtida quando a amostragem é orientada por software específico, em tantas imagens e células quanto indicadas por este software. Métodos: Foi realizado um estudo transversal, comparando as amostras endoteliais com e sem a intervenção do software. A amostra foi composta de 298 olhos de 149 pacientes, divididos em dois grupos: Grupo 1: composto pelos dados amostrais dos exames considerados corretos pelo software Cells Analyzer PAT. REC com 1 imagens e Grupo 2 que foi subdividido em 2 grupos- Grupo 2 A: composto pelos dados amostrais da primeira imagem dos exames considerados incorretos pelo software Cells Analyzer PAT. REC; e - Grupo 2 B: composto pelos dados amostrais dos exames que consideram tantas imagens quantas necessárias para que o exame seja considerado completo pela análise do software Cells Analyzer PAT. REC.. Foram realizadas três tipos de comparação : comparação 1: Grupo 1 X Grupo 2 A; comparação 2- Grupo 2 A X Grupo 2 B e comparação 3 - Grupo 1 X Grupo 2 B. Resultados: As três comparações demonstraram que os grupos apresentam perfis amostrais distintos, porém, dentro dos grupos estudados - Grupo 1, Grupo 2 A e Grupo 2 B - existe um perfil de homogeneidade amostral evidenciado pelo resultado da análise estatística empregada a partir de dados amostrais calculados pelo Cells Analyzer PAT. REC na amostra composta pelos 298 exames endoteliais estudados. Conclusão: O estudo dos dados amostrais sem e com a intervenção do software Cells Analyser PAT. REC se mostrou estatisticamente diferente, com amostras maiores e erros amostrais menores, o que evidencia a importância do seu uso para se obter exames de microscopia especular de córnea com representatibilidade, padronização e reprodutibilidade. __________________________________________________________________________________________ ABSTRACT / Purpose: To describe differences among number of cells, evaluated endothelial area and relative error comparing endothelial samples from one endothelial image with endothelial samples obtained from guidance of a specific software, with number of cells and images as many as necessary. Methods: A transversal study was performed, comparing the endothelial samples with and without intervention of the software. The sample consisted of 298 eyes of 149 individuals. The sample was divided in two groups: group 1: data from 141 eyes considerate correct with one image; group 2: in 157 eyes was necessary to get more than one image for the sample be admited as correct; the group 2 was further divided into two subgroups: 2.A: the data of the first image and group 2. B: data of complete sample. Three comparasions were perfomed: comparation 1: Group 1 x Group 2 A; comparation 2: 2AX 2 B and comparation 3: Group A X group 2. B. Results: The statistic comparations of sample’s data (number of counting cells, evaluate field,and relative error) of the Group 1 X group 2 A, Groups 2 A X 2 B and Group A X group 2 B;showed that groups had different sample. Conclusion: The study of sample’s data with or without the analysis of the software Cells Analyzer PAT. REC showed statistically significant differences showing clearly the importance of using it in order to obtain representative, standardized and reproducible specular microscopy exam.
3

Morfologia e morfometria do endotélio corneal de gatos (Felis catus - Linnaeus, 1758) de diferentes idades à microscopia especular

Franzen, Angela Aguiar [UNESP] 04 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-04Bitstream added on 2014-06-13T18:51:10Z : No. of bitstreams: 1 franzen_aa_me_jabo.pdf: 432317 bytes, checksum: 6e76f84b35fefc0d8afc5bb52873a43f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O endotélio corneal é essencial para a manutenção da transparência da córnea, é necessário um número mínimo de células endoteliais para a manutenção desta transparência. As alterações morfológicas e morfométricas do endotélio da córnea de gatos decorrentes do avanço da idade não estão ainda compreendidas e elucidadas. Objetivou-se estudar os parâmetros morfológicos e morfométricos do endotélio da córnea de gatos de diferentes idades, utilizando-se a microscopia especular. Avaliaram-se a densidade celular, a área celular média, o pleomorfismo e o polimegatismo. Empregaram-se 18 animais da espécie felina (Felis catus - LINNAEUS, 1758), machos ou fêmeas, subdivididos em três grupos com 6 animais cada, designados por: G1 (animais com idade entre 1 a 3 meses); G2 (animais com idade entre 5 a 12 meses) e G3 (animais com idades entre 24 a 40 meses). A microscopia especular de contato revelou que com o avanço da idade a densidade celular endotelial diminuiu, a área celular média e o pleomorfismo aumentaram e o polimegatismo apresentou valores constantes nos 3 grupos estudados. / The corneal endothelium is essential to maintain the corneal transparency. Morphological and morphometric changes in the feline corneal endothelium as a function of age are little known. The purpose of this study was investigating the effect of age on endothelial morphology and morphometry in cats. The corneal endothelium was studied throught contact specular microscopy. The exam presented data as cell density, average cell area, polymegathism and pleomorphism. A total of 16 cats were evaluated in this study. The subjects were divided in three groups with six cats (Felis catus - LINNAEUS, 1758): G1 (cats with 1 to 3 months old); G2 (cats with 5 to 12 months old); G3 (cats with 24 to 40 months old). The specular microscopy revealed decrease of cell density with age. The cell area increase and pleomorphism increase as function of age. The polymegathism showed constants values on the three groups.
4

Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal / Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal / Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal / Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal

SILVA, Rodrigo Salustiano Corrêa e 12 June 2012 (has links)
Made available in DSpace on 2014-07-29T15:25:21Z (GMT). No. of bitstreams: 1 tesedefendidarodrigo.pdf: 1424160 bytes, checksum: ba481cb9361d272aa1bf192493e601ce (MD5) Previous issue date: 2012-06-12 / To evaluate corneal endothelium by means of specular microscopy exam in patients with keratoconus, before and after Cornealring® corneal intrastromal ring surgery. A hundred and two eyes of sixty-seven patients, aged between 12 and 45, with the average age of 27,31 ± 8,15 years, 30 of whom females and 37 males, were selected to be submitted to the implant of Cornealring® corneal ring segments and evaluation of the corneal endothelium in the pre and post surgery (six months after the procedure) in the External Diseases and Cornea Ward of the Instituto Panamericano da Visão. Data have been stored for later analysis by software SPSS (Statistical Package of Social Science) for Windows 15.0. Only the eyes receiving two rings with 250 μ thickness showed significant statistical difference (p = 0,008). The remaining eyes showed no statistical difference (initial x final). In relation to the thickness and to the number of implanted rings, a decrease in the final coefficient was observed in most implanted rings. However, only the eyes that received two rings 250 μ thick showed significant difference (p=0,003), with a decrease of 10,1% in the coefficients of variation average. In relation to the thickness and number of implanted rings, a decrease in the percentage of hexagonal cells was observed (before and after surgery). Only the eyes that received two rings 250 μ thick showed a highly significant decrease (p=0,001) in relation to the hexagonal percentage of 9,7%. Although the parameters in the specular microscopy showed alterations mainly in the thicker rings, all the patients showed transparent corneas without clinical signs of endothelial suffering along the six months of follow-up. A longer period of study must be considered for better understanding and interpretation of the results obtained, in order to establish any relationship between eventual complications and the thickness of the implanted ring. / A tese tem por objetivo avaliar o endotélio corneal por meio de microscopia especular, de pacientes portadores de ceratocone, antes e após a cirurgia corneal pela técnica de anel intraestromal, utilizando o implante Cornealring®. Cento e dois olhos de 67 pacientes, com idade entre 12 e 45 anos (com média 27,31 ± 8,15 anos), sendo 30 do sexo feminino e 37 do sexo masculino, foram selecionados para serem submetidos ao implante dos segmentos do anel Cornealring® e avaliação do endotélio corneal no pré e pós-operatório, seis meses após o procedimento, no serviço de Doenças Externas e Córnea do Instituto Panamericano da Visão. Os dados foram armazenados, para posterior análise no software Statistical Package of Social Science (SPSS) para Windows, versão 15.0. Apenas os olhos que receberam dois anéis de espessura de 250 μ apresentaram diferença estatisticamente significativa da densidade endotelial (p = 0,008). Nos demais olhos, não houve diferença estatística (antes e após a cirurgia corneal). Notou-se que, na maioria das espessuras de anéis utilizados, houve uma diminuição do coeficiente de variação após a cirurgia corneal. Porém, só os olhos que receberam dois anéis de espessuras de 250 μ mostraram diferença significativa (p=0,003), com uma diminuição de 10,1% na média do coeficiente de variação. Observou-se diminuição no percentual de células hexagonais em relação, no tocante à espessura e à quantidade de anéis implantados. Somente os olhos que receberam os dois anéis de espessura de 250 μ mostraram diminuição altamente significativa (p=0,001), em relação ao percentual hexagonal de 9,7%. Apesar de os parâmetros na microscopia especular mostrarem-se alterados, sobretudo nos anéis com espessura maior, todos os pacientes apresentaram córneas transparentes sem sinais clínicos de sofrimento endotelial ao longo dos seis meses de seguimento. Maior tempo de estudo deve ser considerado para melhor compreensão e interpretação dos resultados encontrados, a fim de ser estabelecida alguma relação entre possíveis complicações e a espessura do anel implantado.

Page generated in 0.0757 seconds