• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 2
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determina??o de Verapamil e Oxcarbazepina em amostras de urina e formula??es farmac?uticas por amperometria pulsada em FIA

Lima, Amanda Barbosa January 2016 (has links)
Data de aprova??o ausente. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2017-03-24T17:42:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-04-20T19:16:33Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) / Made available in DSpace on 2017-04-20T19:16:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) Previous issue date: 2016 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Verapamil (VP) e Oxcarbazepina (OX) s?o f?rmacos de baixo ?ndice terap?utico que necessitam de rigoroso controle de qualidade em formula??es farmac?uticas, bem como de an?lises em fluidos biol?gicos para estudos farmacol?gicos de elimina??o dessas drogas. Neste sentido, o desenvolvimento de m?todos simples, r?pidos e de baixo custo ? de extrema import?ncia para quantifica??o desses f?rmacos nessas amostras. Deste modo, o presente trabalho apresenta um m?todo eletroanal?tico em fluxo para determinar VP e OX tanto em formula??es farmac?uticas, quanto em amostras de urina. A t?cnica eletroqu?mica utilizada para quantifica??o foi a Amperometria de M?ltiplos Pulsos (MPA) acoplada a um sistema de an?lise por inje??o em fluxo (FIA), utilizando o diamante dopado com boro (BDD). Foram aplicados tr?s pulsos de potencial pela MPA para determina??o do VP em meio de ?cido sulf?rico 0,1 mol L-1, sendo +1,6 V para a oxida??o e, posteriormente, +0,2 V para redu??o do produto gerado do VP e +0,1 V para a limpeza do eletrodo de BDD. Para a determina??o de OX, tamb?m foram otimizados tr?s pulsos de potencial em meio de tamp?o acetato 0,1 mol L-1 (pH 4,0), sendo + 1,7 V para a oxida??o da OX e gera??o do produto que foi reduzido em -1,1 V e -1,3 V para a limpeza do eletrodo de BDD. Em ambos os casos, apenas o sinal obtido nos pulsos de potencial de redu??o foram utilizados para quantifica??o dos f?rmacos. As faixas lineares de trabalho obtidas para quantifica??o do VP e da OX foram de 0,8 a 40,0 ?mol L-1 (R= 0,9976) e 2,0 a 80,0 ?mol L-1 (R= 0,9989), respectivamente. Os limites de detec??o foram calculados em 0,16 ?mol L-1 para VP e 0,42 ?mol L-1 para OX. Uma boa repetibilidade foi obtida para 10 an?lises consecutivas desses f?rmacos, com desvio padr?o relativo de 2,2% para VP e 0,94 % para OX. Os estudos de adi??o e recupera??o do VP e OX em amostras farmac?uticas e urina apresentaram resultados pr?ximos a 100% e o doseamento do VP foi validado pela metodologia oficial. Altas frequ?ncias anal?ticas foram alcan?adas pelo sistema FIA com 45 e 65 determina??es por hora de VP e OX, respectivamente, usando al?as de amostragem inferiores a 200 ?L e vaz?es de 3,5 mLmin-1. An?lises desses f?rmacos em amostras de urina mostraram que ? poss?vel determin?-los mesmo na presen?a de altas concentra??es de ?cido asc?rbico e ?cido ?rico. Portanto, o m?todo proposto mostrou-se como alternativa simples e r?pida para quantifica??o desses f?rmacos em formula??es farmac?uticas e urina. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, [2016]. / Verapamil (VP) and Oxcarbazepine (OX) are drugs of narrow therapeutic index that require strict quality control in pharmaceutical formulations and analysis in biological fluids for pharmacological studies of elimination of these drugs. In this sense, the development of simple, fast and low-cost methods is very important to quantify these drugs in pharmaceutical samples. Therefore, this work presents a electroanalytical method in flow for determining VP and OX in pharmaceutical formulations and human urine samples. The electrochemical technique used for quantification was performed by multiple pulses amperometry (MPA) coupled to a flow injection analysis system (FIA), using boron-doped diamond (BDD) as working electrode. Were applied three potential pulses by MPA for the determination of VP in sulfuric acid 0.1 mol L-1: (1) +1.6 V for oxidation of VP, (2) +0.2 V for reduction of the generated product of VP in the fisrt potential pulse, (3) +0.1 V for cleaning of the BDD electrode surface. The determination of OX also was performed by MPA in three potential pulses in 0.1 mol L-1 acetate buffer (pH 4.0): (1) +1.7 V for oxidation of OX and generation of the product that it was reduced at (2) -1.1 V, and (3) -1.3 V for cleaning of the BDD electrode surface. In both cases, only the signal obtained in the reduction potential pulses were used for quantification of drugs. The linear ranges of work obtained for quantitation of VP and OX were 0.8 to 40.0 ?mol L-1 (R = 0.9976) and 2.0 to 80.0 ?mol L-1 (R = 0, 9989), respectively. The detection limits were calculated to be 0.16 ?mol L-1 for VP and 0.42 ?mol L-1 for OX. Good repeatabilities were obtained for 10 consecutives injections of these drugs, with relative standard deviation of 2.2% for VP and 0.94% for OX. The addition and recovery studies for VP and OX in pharmaceutical and urine samples were close to 100% and determination of VP was validated by the official methodology. High analytical frequencies were achieved by FIA system of 45 and 65 determinations per hour for VP and OX, respectively, using sampling handles less than 200 ?L and flow rate of 3.5 mLmin-1. The analysis of these drugs in urine showed that it is possible to determine this sample even in the presence of high concentrations of ascorbic acid and uric acid. Therefore, the present method by MPA-FIA proved to be a quick and easy alternative to quantify VP and OX in pharmaceutical formulations and urine.
2

Avalia??o do comportamento eletroqu?mico da cotinina no eletrodo de diamante dopado com boro e estudos para sua determina??o em saliva por amperometria pulsada em fluxo

Alecrim, Morgana Fernandes January 2016 (has links)
Data de aprova??o ausente. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2016-12-20T14:07:54Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-01-17T18:51:10Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) / Made available in DSpace on 2017-01-17T18:51:10Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) Previous issue date: 2016 / A Cotinina (CO) ? o principal metab?lito da nicotina, sendo utilizada como biomarcador para monitorar a exposi??o de um indiv?duo ao tabaco. Os m?todos comumente utilizados para a determina??o desse composto em amostras biol?gicas s?o baseados na cromatografia l?quida, os quais, em geral, s?o dispendiosos e requerem tratamentos tediosos dessas amostras. Dessa maneira, torna-se necess?rio o desenvolvimento de novos m?todos mais simples e r?pidos para determina??o da CO. Nesse contexto, o presente trabalho prop?e o uso eletrodo de diamante dopado com boro (BDD) para detec??o e caracteriza??o eletroqu?mica da CO por t?cnicas voltam?tricas, bem como sua quantifica??o em amostras de saliva por meio da amperometria de m?ltiplos pulsos (MPA) em sistema de an?lise por inje??o em fluxo (FIA). Em meio de tamp?o fosfato a 0,1 mol L-1 (pH 7) a CO apresentou dois processos eletroqu?micos, um an?dico em +1,8 V e um cat?dico em -1,2 V (vs. Ag/ AgCl), sendo o segundo dependente do primeiro e ambos de car?ter irrevers?vel. Foi verificado que o processo de transporte de massas para a oxida??o da CO ? preferencialmente difusional sobre o eletrodo de BDD e que 2 el?trons e pr?tons est?o envolvidos na rea??o eletroqu?mica. O coeficiente de difus?o calculado para a CO foi de 5,7 x 10 -2 cm2 s-1. Para determina??o da CO em saliva, MPA foi utilizada aplicando-se 4 pulsos de potencial, sendo: (1) em +1,8 V/ 400 ms potencial gerador (EG) para oxida??o da CO; (2) em -1,0 V/ 500 ms potencial para elimina??o de interferentes na amostra de saliva, (3) em -1,2 V/ 30 ms potencial coletor para reduzir e quantificar a CO gerada pelo EG; (4) em -145/ 300 ms potencial para limpeza da superf?cie do BDD. A freq??ncia anal?tica te?rica foi obtida de 24 determina??es por hora com uma vaz?o otimizada em 3,0 mL min-1 e a al?a de amostragem de 300 ?L no sistema FIA. Al?m disso, um baixo desvio padr?o relativo de 1,46% foi obtido para 10 determina??es consecutivas de CO 10 ?mol L-1. Nessas condi??es, foi obtida uma faixa linear de 0,5 a 100 ?mol L-1 (R= 0,998) com limite de detec??o calculado em 0,18 ?mol L-1 para CO. Os estudos de adi??o e recupera??o da CO em amostras de saliva foram de 96,77%, Portanto, mediante a caracteriza??o eletroqu?mica e os estudos por FIA-MPA usando eletrodo de BDD, este trabalho apresenta uma alternativa simples, r?pida e de baixo custo para monitoramento do grau de exposi??o ao tabaco pela determina??o da CO em amostras de saliva. / Disserta??o (Mestrado) ? Programa de P?s-gradua??o em Ci?ncias Farmac?uticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, [2016]. / The Cotinine (CO) is the major metabolite of the nicotine an disused as a biomarker to monitor the exposure of an individual to tobacco. The methods commonly used for CO determination in biological samples are based on liquid chromatography, which generally are expensive and require tedious treatments of the samples. Thus, it becomes necessary to develop simpler and faster methods for determining CO. In this context, this paper proposes the use boron-doped diamond (BDD) film electrode for the detection and electrochemical characterization of CO by voltammetric techniques and, CO quantification in saliva samples by multiple-pulse amperometry (MPA) in analysis by flow injection (FIA) system. In phosphate buffer solution 0.1 mol L-1 (pH 7), the CO presented two electrochemical processes, one anodic at + 1.8V and one cathode at -1.2V (vs. Ag/ AgCl), with the second process dependent on the first and both irreversible process. It was found that CO electrochemical processes are controlled by diffusion and, two-protons and two-electrons are involved in the oxidation reaction. The diffusion coefficients calculated for CO was 5.7 x 10 -2 cm2 s-1. In determination of CO in saliva samples, the MPA detection was used applying four potential pulses: (1) at +1.8V/ 400ms ? generator potential pulse (EG) for oxidation of CO; (2) at-1.0V/500ms - potential for remove possible interferents, (3) at - 1.2V/30ms - collector potential pulse potential for reduction of the product generated by EG and CO quantification; (4) at-14.5V/ 300 ms- potential pulse for cleaning BDD electrode. The proposed method obtained a theoretical analytical frequency with 24 determinations per hour by FIA system in flow rate of 3.0 ml min-1 and sample loop of 300?L. Furthermore, a low relative standard deviation of 1.46% was obtained for 10 measurements of CO 10 ?mol L-1. Under these conditions, A good linear range from 0.5 to 100 ?mol L-1 (R = 0.998) was obtained with a detection limit estimated at 0.18 ?mol L-1 for CO. The addition and recovery studies of CO in saliva samples were 96.77%. Therefore, this work presents, by the first time, an electrochemical characterization of the CO and a method simple, fast and low cost for monitoring the degree of exposure to tobacco by CO determination in saliva samples using FIA-MPA technique.
3

Uso do método do padrão interno em sistemas FIA e BIA e determinação simultânea de diclofenaco e codeína em formulações farmacêuticas por amperometria de múltiplos pulsos / Use of the internal standard method in FIA and BIA systems and determination of diclofenac and codeine in pharmaceutical formulations by multiple pulse amperometry

Gimenes, Denise Tofanello 25 July 2013 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The present thesis demonstrates, for the first time, the possibility of using of the internal standard method in FIA or BIA systems with amperometric detection. The method allows to obtain accurate results in the presence of fluctuations in the system parameters (injected volume, dispensing rate, ionic strength and accidental insertion of air bubbles) and in the presence of contamination and/or gradual passivation of the working electrode surface. Methods for determination of diclofenac (DCF) using FIA with amperometric detection and simultaneous determination of DCF and codeine (CO) by BIA with amperometric detection have also been developed. The internal standard method was implemented in the flow injection analysis with multiple pulse amperometric detection (FIA-MPA) system by applying a sequence of potential pulses of the working electrode as a function of time. The analyte (+0.80 V/300ms) and internal standard (-0.05 V/400ms) were detected selectively, one at each potential pulse. Significant improvements were obtained in the accuracy of the system when the results before and after normalization (using the internal standard method), were compared. The following errors were calculated, respectively, before and after normalization of the results using the internal standard method. Change in flow rate from 3.0 to 1.0 ml min-1 (-57% e < 1%); volume injection from 300 to 100 &#956;L (-63% and 3%); ionic strength from 0.60 to 0.77 mol L-1 (-44 and 0,2%) and before and after the introduction of air bubbles into the system (-9,6% and 1,7%). A significant improvement was also obtained in the correlation coefficient of the calibration curve in the presence of problems of passivation or contamination of the working electrode. The correlation coefficient was calculated, respectively, as 0,975 and 0,998, before and after the normalization of the results by the IS method. The internal standard method was also applied to correct errors derived from the injection procedure (dispensing rate and injected volume) in batch injection analysis systems (BIA) with amperometric detection when disposable syringes were used. The results obtained before and after normalization of the results by the IS method were the following, respectively: repeatability test (RSD = 6.4 and 1.8%; n = 8), correlation coefficients (R=0.954 and 0.997) and errors obtained in analysis of synthetic samples (E = 9.4 ± 1.5 and 3.5 ± 0.7%; n = 8). The determination of DCF by FIA-MPA was implemented by applying two potential pulses to the BDD electrode using H2SO4 0.1 mol L-1 as supporting electrolyte: (i) + 1.2 V / 50 ms for oxidation and quantification of DCF, and (ii) 0.0 V / 50 ms for constant electrochemical cleaning of the electrode surface. The system showed good stability (RSD = 1.0%, n = 10) and high analytical frequency (135 injections h-1). The method showed a linear response between 5 and 50 &#956;mol L-1 and the detection and quantification limits were as 0.14 and 0.46 mmol L-1, respectively. The proposed method was applied to determine of DCF in pharmaceutical formulations and the obtained results were similar to those obtained by HPLC with a confidence level of 95%. The simultaneous determination of DCF and CO was performed using the following potential pulses: (i) +1.1 V / 50 ms: oxidation and quantification of DCF; (ii) +1.4 V / 50 ms: simultaneous oxidation of DCF and CO, (iii) 0.0 V / 200 ms: for constant electrochemical cleaning of the BDD electrode. The oxidation current from CO was obtained by the difference between currents detected at 1.4 and 1.1 V by using a correction factor. The system showed good stability (RSD = 0.9% and 1.1 for DCF and CO respectively, n = 10) and high analytical frequency (~ 300 injections h-1). The method showed a linear response between 10 and 50 &#956;mol L-1 for DCF and 7.1 and 35.7 &#956;mol L-1 for CO. The LQ and LD were calculated, respectively, at 1.1 and 3.7 &#956;mol L-1, for DCF and 1.0 and 3.3 mol L-1 for CO. The proposed method was applied for simultaneous determination of DCF and CO in pharmaceutical formulations and the obtained results were similar to those obtained by HPLC with a confidence level of 95%. Keywords: Multiple pulse amperometry, FIA, BIA, internal standard, simultaneous analysis, boron doped diamond (BDD), codeine, diclofenac. / Esta tese apresenta, pela primeira vez, a possibilidade de usar o método do padrão interno em sistemas FIA ou BIA com detecção amperométrica. O método permite a obtenção de resultados precisos na presença de flutuações em parâmetros dos sistemas (volume injetado, velocidade de injeção, força iônica e inserção acidental de bolhas de ar) e na presença de contaminação e/ou passivação gradual do eletrodo de trabalho. Métodos para determinação de diclofenaco (DCF) usando FIA com detecção amperométrica e simultânea de DCF e codeína (CO) por BIA com detecção amperométrica também foram desenvolvidos. O método do padrão interno foi implementado no sistema de análise por injeção em fluxo com detecção por amperometria de múltiplos pulsos (FIA-MPA) mediante a aplicação de uma sequência de pulsos de potenciais ao eletrodo de trabalho em função do tempo. O analito (+0,80 V/300ms) e o padrão interno (-0,05 V/400ms) foram detectados seletivamente, um em cada pulso de potencial. Melhoras significativas foram obtidas na precisão do método quando os resultados obtidos antes e após a normalização (usando o método do padrão interno) foram comparados. As seguintes variações foram calculadas, respectivamente, antes e após a normalização dos resultados usando o método do padrão interno. Variação na velocidade de vazão de 3,0 para 1,0 mL min-1 (-57% e < 1%); no volume de injeção de 300 para 100 &#956;L (-63% e 3%); força iônica de 0,60 para 0,77 mol L-1 (-44 e 0,2%) e antes e após a inserção de bolhas de ar no sistema (-9,6% e 1,7%). Uma melhora significativa também foi obtida no coeficiente de correlação da curva de calibração na presença de problemas de passivação ou contaminação do eletrodo de trabalho. O coeficiente de correlação foi calculado, respectivamente, em 0,975 e 0,998, antes e após a normalização dos resultados pelo método do PI. O método do padrão interno também foi aplicado para corrigir erros em sistemas de análise por injeção em batelada (BIA) com detecção amperométrica provenientes do procedimento de injeção (velocidade de injeção e volume injetado) quando seringas descartáveis foram utilizadas. Os resultados obtidos antes e após a normalização dos resultados pelo método do PI foram os seguintes, respectivamente: estudo de repetibilidade (DPR=6,4 e 1,8%; n = 8), coeficientes de correlação (R=0,954 e 0,997) e erros obtidos na análise de amostras sintéticas (9,4 ± 1,5% e 3,5 ± 0,7; n = 8). A determinação de DCF por FIA-MPA foi implementada através da aplicação de dois pulsos de potenciais ao eletrodo de BDD em meio de H2SO4 0,1 mol L-1 como eletrólito suporte: (i) +1,2 V / 50 ms para oxidação e quantificação do DCF e, (ii) 0,0 V / 50 ms para constante limpeza eletroquímica do eletrodo de trabalho. O sistema apresentou boa estabilidade (RSD = 1,0%; n=10) e elevada frequência analítica (135 injeções h-1). O método apresentou resposta linear entre 5 e 50 &#956;mol L-1 e os limites de detecção e quantificação foram calculados em 0,14 e 0,46 &#956;mol L-1, respectivamente. O método proposto foi aplicado na determinação de DCF em formulações farmacêuticas e os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de 95%. A determinação simultânea de DCF e CO foi realizada usando os seguintes pulsos de potenciais: (i) +1,1 V / 50 ms: oxidação e quantificação de DCF; (ii) +1,4 V / 50 ms: para oxidação simultânea de DCF e CO; (iii) 0,0 V / 200 ms: para constante limpeza eletroquímica do eletrodo de BDD. A corrente de oxidação da CO foi obtida pela subtração entre as correntes detectadas em 1,4 e 1,1 V mediante uso de um fator de correção. O sistema apresentou boa estabilidade (RSD= 1,1 e 0,9% para DCF e CO, respectivamente, n=10) e elevada frequência analítica (~300 injeções h-1). O método apresentou resposta linear entre 10 e 50 &#956;mol L-1 para o DCF e entre 7,1 e 35,7 &#956;mol L-1 para CO. O LD e o LQ foram calculados, respectivamente, em 1,1 e 3,7 &#956;mol L-1, para DCF e 1,0 e 3,3 &#956;mol L-1 para CO. O método proposto foi aplicado na determinação simultânea de DCF e CO em formulações farmacêuticas e os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de 95%. / Doutor em Química
4

Determina??o da teofilina, clindamicina, varfarina e verapamil por amperometria pulsada em sistema de an?lise por inje??o em batelada usando o eletrodo de diamante dopado com boro

Andrade, Glauber Ant?nio dos Reis 24 March 2016 (has links)
?rea de concentra??o: Qu?mica anal?tica. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2016-12-21T13:02:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) glauber_antonio_reis_andrade.pdf: 2400963 bytes, checksum: 99ec593844d6ba3a1107158d86656739 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-01-21T11:09:00Z (GMT) No. of bitstreams: 2 license_rdf: 9 bytes, checksum: 42dd12a06de379d3ffa39b67dc9c7aff (MD5) glauber_antonio_reis_andrade.pdf: 2400963 bytes, checksum: 99ec593844d6ba3a1107158d86656739 (MD5) / Made available in DSpace on 2017-01-21T11:09:00Z (GMT). No. of bitstreams: 2 license_rdf: 9 bytes, checksum: 42dd12a06de379d3ffa39b67dc9c7aff (MD5) glauber_antonio_reis_andrade.pdf: 2400963 bytes, checksum: 99ec593844d6ba3a1107158d86656739 (MD5) Previous issue date: 2016 / A Teofilina (TF), Clindamicina (CM), Varfarina (VF) e Verapamil (VP) s?o f?rmacos de baixo ?ndice terap?utico que necessitam de um controle de qualidade rigoroso na elabora??o de suas formula??es. O desenvolvimento de m?todos mais simples e r?pidos para doseamento desses medicamentos ? de grande interesse no setor farmac?utico. Neste sentido, o presente trabalho apresenta uma nova metodologia para determina??o desses f?rmacos por amperometria de m?ltiplos pulsos (MPA) acoplada ao sistema de an?lise por inje??o em batelada (BIA), utilizando o eletrodo de Diamante dopado com Boro (DDB). A an?lise em BIA foi realizada em uma c?lula eletroqu?mica do tipo Wall Jet, onde as inje??es foram realizadas por meio de uma micropipeta autom?tica ou, manualmente, por uma seringa descart?vel para TF, CM e VF, mostrando a possibilidade de diminuir custo do sistema de an?lise. O comportamento eletroqu?mico da TF, CM, VF e VP foi investigado por voltametria c?clica e os eletr?litos suportes escolhidos foram o ?cido sulf?rico 0,1 mol L-1, tamp?o fosfato 0,1 mol L-1 (pH 7,0), tamp?o fosfato 0,1 mol L-1 (pH 7,0) com 10% de ?lcool et?lico e ?cido sulf?rico 0,2 mol L-1, respectivamente. Nesses eletr?litos tr?s f?rmacos apresentaram um ?nico processo de oxida??o: a TF em +1,33V, a CM em +1,18 V e a VF em +0,90 V. J? o VP apresentou tr?s processos de oxida??o entre +1,2V e +1,5V, al?m de um processo de redu??o em +0,2V depende das oxida??es. A detec??o MPA-BIA foi baseada na aplica??o de um pulso de potencial de detec??o e outro de limpeza do DDB para tr?s f?rmacos. Neste caso, os pulsos de potencial para detec??o da TF, CM e VF foram todos aplicados por 100ms em +1,5V, +1,6V e +1,2V, respectivamente. Para determina??o do VP foram utilizados tr?s pulsos de potencial, um para oxida??o do VP (gerador) em +1,6V/50ms, um para redu??o do produto gerado (coletor) e quantifica??o do VP em -0,1V/30ms, e um terceiro em +1,1V/100ms para limpeza da superf?cie do DDB. A velocidade de inje??o da MA foi otimizada em 100?L s-1, exceto para VP que foi de 47?Ls-1, e com a SD a velocidade de inje??o foi de aproximadamente 107 ?Ls-1 pra a TF, CM e VF, proporcionando uma frequ?ncia anal?tica te?rica de pelo menos 53 determina??es por hora desses f?rmacos. Um baixo desvio padr?o relativo (10 medidas) foi obtido para todos os f?rmacos, n?o ultrapassando 3,0% tanto pela inje??o autom?tica quanto pela manual. As curvas anal?ticas foram estabelecidas e uma boa faixa linear foi obtida para todos os f?rmacos com pelo menos duas ordens de concentra??o. Os coeficientes de correla??o linear para todas as regress?es foram maiores que 0,992 em todos os estudos. Os estudos de adi??o e recupera??o mostraram valores pr?ximos a 100 % para todas as amostras farmac?uticas analisadas. O m?todo proposto usando a inje??o autom?tica e manual foi devidamente validado pelo m?todo oficial para cada um dos f?rmacos avaliados. Portanto, a detec??o MPA-BIA usando o eletrodo de DDB mostrou ser uma alternativa mais simples e r?pida para determina??o da TF, CM, VF e VP em formula??es farmac?uticas, possibilitando ainda uma diminui??o do custo do sistema BIA pela substitui??o da micropipeta autom?tica por uma seringa descart?vel. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2016. / Theophylline (TF), Clindamycin (CM), Warfarin (VF) and Verapamil (VP) are drugs of narrow therapeutic index that require a strict quality control in the preparation of their formulations. Thus, the development of simple and rapid methods for determination of these drugs is very important in the pharmaceutical industry. In this sense, this paper presents a new methodology for determination of these drugs by multiple-pulse amperometry (MPA) coupled to batch injection analysis (BIA), using the boron-doped diamond (BDD) electrode. The analysis in BIA system was performed in an electrochemical cell (Wall Jet), where the injections were performed by automatic micropipette or manually by an disposable syringe for TF, CM and VF, showing a possibility to reduction of the analysis cost. The electrochemical behavior of the analytes was investigated by cyclic voltammetry and the support electrolytes were chosen for TF, CM, VF and VP in medium of sulfuric acid 0.1 mol L-1, phosphate buffer 0.1 mol L-1 (pH 7.0), phosphate buffer 0.1 mol L-1 (pH 7.0) with 10% ethyl alcohol and sulfuric acid 0.2 mol L-1, respectively. In these conditions, three drugs exhibited a single oxidation process: TF in +1.33V, the CM in +1.18V and the VF in +0.90V (vs Ag/AgCl). Already the VP presented three oxidation processes between +1.2V and +1.5V, besides a reduction process in +0.20 V that depends on the oxidation. The MPA-BIA detection for three drugs (TF, CM, VF) was based on the application of two potential pulses, one for detection and other for cleaning BDD electrode. In this case, the potential pulses to detection the TF, CM and VF were all applied for 100ms at +1.5V, +1.2V and +1.6 V, respectively. In determination of the VP, were used three potential pulses, one for oxidation of VP (generator potential pulse) in +1.6V/50ms, one for reducing the generated product (collector potential pulse) and performed quantification of VP in -0.1V/30ms, and a third potential pulse at +1.1V/100ms for cleaning BDD electrode. The injection speed using automatic micropipette was 100?L s-1, except for VP that was 47?Ls-1, and injection speed by insulin syringe was approximately 107?Ls-1, which provide theoretical analytical frequency of at least 53 determinations per hour of these drugs. A low standard relative deviation (10 measures) was obtained for all drugs, not extending beyond 3.0% by both injections systems. The analytical curves were established and a good linear range was obtained for all drugs with at least two orders of concentration. The linear correlation coefficients for all regressions were higher than 0.992. The addition and recovery studies show values close to 100% for all drug samples analyzed. The proposed method using automatic and manual injection was validated by official method for each analyte. Therefore, this paper presented a fast and simple method for the determination of TF, CM, VF and VP in pharmaceutical formulations using BIA-MPA detection with BBD electrode. Moreover, this work demonstrated an inexpensive method for application in routine analysis of narrow therapeutic index drugs, mainly using a manual injection in BIA system by an disposable syringe.
5

Využití potenciálových programů při průtokovém elektrochemickém stanovení biologicky aktivních organických látek / Utilization of potential programs in flow electrochemical determination of biologically active organic compounds

Bavol, Dmytro January 2018 (has links)
9 Abstract In this Ph.D. thesis possibilities of using our proposed potential programs for a multiple-pulse amperometry and a fast scan differential pulse voltammetry in combination with flow systems are presented. The development of new sensitive amperometric and voltammetric methods for the determination of oxidisable biologically active organic compounds is another aim of this work. In the first part of the work, the flow injection system and multiple-pulse amperometric detection were employed to develop and optimize a simple, low-cost, and rapid method for the simultaneous determination of natural and synthetic antioxidants. This technique involves the application of an appropriate potential waveform consisting of a suitable sequence of pulses on a single working electrode, thus allowing distinguish the analytes in a mixture with no need of separation. Conditions for the determination of antioxidants and modelling of the potential program were tested and studied, respectively. Second part of the work describes and characterizes the application of the fast scan differential pulse voltammetry (FSDPV) in combination with the flow systems. FSDPV is the electroanalytical technique that use high scan rate to record voltammograms within several milliseconds and ensures high temporal resolution. This technique...
6

Využití potenciálových programů při průtokovém elektrochemickém stanovení biologicky aktivních organických látek / Utilization of potential programs in flow electrochemical determination of biologically active organic compounds

Bavol, Dmytro January 2018 (has links)
9 Abstract In this Ph.D. thesis possibilities of using our proposed potential programs for a multiple-pulse amperometry and a fast scan differential pulse voltammetry in combination with flow systems are presented. The development of new sensitive amperometric and voltammetric methods for the determination of oxidisable biologically active organic compounds is another aim of this work. In the first part of the work, the flow injection system and multiple-pulse amperometric detection were employed to develop and optimize a simple, low-cost, and rapid method for the simultaneous determination of natural and synthetic antioxidants. This technique involves the application of an appropriate potential waveform consisting of a suitable sequence of pulses on a single working electrode, thus allowing distinguish the analytes in a mixture with no need of separation. Conditions for the determination of antioxidants and modelling of the potential program were tested and studied, respectively. Second part of the work describes and characterizes the application of the fast scan differential pulse voltammetry (FSDPV) in combination with the flow systems. FSDPV is the electroanalytical technique that use high scan rate to record voltammograms within several milliseconds and ensures high temporal resolution. This technique...

Page generated in 0.0562 seconds