• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 21
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 58
  • 58
  • 23
  • 23
  • 18
  • 17
  • 16
  • 16
  • 15
  • 15
  • 15
  • 14
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Vessani, Roberto Murad 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
42

Compression nerveuse chronique : évaluation des complications fonctionnelles et moléculaires sur la microcirculation cutanée et la régénération nerveuse / Chronic nerve compression : study of functional and molecular impairments on cutaneous microcirculation and nervous regeneration

Pelletier, Julien 14 November 2011 (has links)
La compression nerveuse chronique (CNC) est un modèle d’étude expérimental définit pour l’examen du syndrome du canal carpien. Notre travail consistait à étudier chez le rat sain, l’effet d’une CNC de courte ou de longue durée sur la microcirculation cutanée, ainsi que la capacité de récupération fonctionnelle du nerf suite à une décompression, et les mécanismes moléculaires impliqués dans la régénération nerveuse. L’originalité de l’équipe de recherche est d’avoir montré un mécanisme physiologique original permettant d’étudier l’interaction neurovasculaire cutanée qui peut être observée sur le nerf. La PIV (Pressure‐Induced Vasodilation) est un outil original de commande de la vasomotricité par les fibres C. Les dysfonctions neurovasculaires cutanées et nerveuses induites par une CNC de courte durée sont associés à l’altération des fibres C et, à des mécanismes angiogéniques et inflammatoires du nerf lésé. Ces atteintes sont réversibles après une décompression nerveuse, malgré une modification de la balance des facteurs angiogéniques, une augmentation de l’expression de facteurs inflammatoires et l’activité de protéines à profil apoptotique. La CNC de longue durée provoque des traumatismes plus importants auxquels s’ajoutent des atteintes vasculaires. Par conséquent la décompression du nerf sciatique n’a pas permis de rétablir les fonctions nerveuses périphériques. La PIV fournit un diagnostic précoce de l’atteinte nerveuse suivant sa réduction, synonyme d’une CNC de courte durée, ou de son abolition, synonyme d’une CNC longue durée. Ces niveaux d’atteintes nerveuses et inflammatoires pourraient être responsables ou non de la récupération fonctionnelle nerveuse / Chronic nerve compression (CNC) is an experimental study model for the examination of the carpal tunnel syndrome. Our work aimed to study the effect of short or long‐term CNC on the cutaneous blood flow, on the nerve ability to recover following to nerve release, and the molecular mechanisms involved in the nervous regeneration. For that purpose, our laboratory established an original physiological mechanism in the study of the relationship between vessel and nerve in the sciatic nerve but also at the periphery, in the cutaneous tissue. Therefore, PIV (Pressure‐Induced Vasodilation) is an original tool of vasomotion linked to C‐fibers. Cutaneous and nervous neurovascular dysfunctions induced by a shortterm CNC were associated to cutaneous C‐fibers impairment and, angiogenic and inflammatory mechanisms of the injured nerve. These achievements are reversible after nerve release, even though the nerve showed a modification of the balance of angiogenic factors, an increase of the expression of inflammatory factors and the activity of proteins with apoptotic type. The long‐term CNC induced more important trauma that further affected the vascular function. Consequently the decompression of the sciatic nerve did not allow restoring the peripheral nervous function. PIV allows to early diagnosing nerve damage with a reduction referring to a short‐term CNC or an abolition referring to a long‐term CNC. Activation of the inflammatory pathway during CNC could compromise nerve recovery following nerve decompression
43

Comparação das medidas da espessura macular e da camada de fibras nervosas retiniana para detecção de atrofia em banda do nervo óptico através da tomografia de coerência óptica / Comparison of macular thickness and retinal nerve fiber thickness measurements for detection of band atrophy of the optic nerve using optical coherence tomography

Frederico Castelo Moura 31 August 2007 (has links)
Pacientes com compressão quiasmática apresentam perda das fibras nervosas da retina nasal que decussam no quiasma óptico. Por conseguinte, ocorre perda das fibras nervosas, predominantemente, no setor nasal e temporal do disco óptico, que se manifesta por atrofia em banda do nervo óptico ao exame oftalmoscópico e hemianopsia temporal ao exame de campo visual. Trabalhos anteriores mostraram que o tomógrafo de coerência óptica é capaz de diferenciar pacientes com atrofia em banda do nervo óptico associada à hemianopsia temporal completa de indivíduos normais através da análise da camada de fibras nervosas peripapilar. Estudos em glaucoma têm sugerido que a avaliação da espessura macular poderia ser útil na quantificação da perda neural como um método alternativo ou complementar ao estudo da camada de fibras nervosas da retina. No presente estudo, a espessura macular e da camada de fibras nervosas foram avaliadas pelo tomógrafo de coerência óptica em pacientes com atrofia em banda do nervo óptico e graus variados de hemianopsia temporal. O desempenho dos parâmetros maculares para detecção da atrofia em banda do nervo óptico foi avaliado pela área sob a curva ROC (AROC) e sensibilidades para especificidades fixas e os resultados foram comparados aos parâmetros da camada de fibras nervosas peripapilar. Para identificar os parâmetros do Stratus OCT que apresentaram melhor desempenho para diferenciar pacientes com AB do nervo óptico de indivíduos normais, modelos de regressão logística foram utilizados. A correlação estrutura-função foi realizada entre o grau do defeito temporal e os valores de espessura macular e da camada de fibras peripapilar através do coeficiente de correlação de Spearman. A categorização diagnóstica dos parâmetros da camada de fibras nervosas através do banco de dados normativos foi avaliada pelos valores de sensibilidade e especificidade calculados pelo teste exato de Fisher. Quarenta e quatro olhos com atrofia em banda e 47 olhos normais foram avaliados no estudo. Entre os parâmetros maculares, os parâmetros da retina nasal apresentaram melhor desempenho para detectar atrofia em banda do nervo óptico comparados aos parâmetros da retina temporal. Não houve diferença significante (p=0,32) entre as áreas sob a curva ROC do melhor parâmetro macular (AROC=0,97) e do melhor parâmetro da camada de fibras nervosas retiniana (AROC=0,99). Na avaliação da correlação estrutura-função, os parâmetros da retina nasal apresentaram maior correlação com o defeito campimétrico comparados aos parâmetros da camada de fibras nervosas da retinal. Entre os parâmetros maculares, a espessura nasal média apresentou a maior correlação (rs=0,618). Entre os parâmetros da camada de fibras nervosas da retina, a espessura média apresentou a maior correlação (rs=0,479). Os parâmetros espessura média, espessura nasal e espessura temporal da camada de fibras nervosas da retina apresentaram melhor desempenho diagnóstico baseado na categorização diagnóstica do banco de dados normativos. Os resultados obtidos no estudo mostraram que os parâmetros maculares discriminam olhos com atrofia em banda do nervo óptico em pacientes com graus variados de defeito temporal. Além disso, os parâmetros da retina nasal podem colaborar com o exame perimétrico e os parâmetros da camada de fibras nervosas para o seguimento dos pacientes com compressão quiasmática. / Patients with chiasmal compression present damage of crossed fibers of nasal retina. Therefore, retinal nerve fiber layer loss occurs predominantly on the nasal and temporal sides of the optic disc, a pattern that can be identified on ophthalmoscopy as band atrophy of the optic nerve and on visual field as temporal hemianopia. Previous studies have been demonstrated that optical coherence tomography is able to detect retinal nerve fiber layer loss in patients with lesions of the optic chiasm and complete temporal hemianopia. Studies in glaucoma have been suggested that macular thickness measurements could be useful in quantification of optical nerve axonal loss as alternative or complement method to evaluate the retinal nerve fiber layer. The purpose of the present study was to compare macular thickness and retinal nerve fiber thickness measurements in patients with band atrophy of the optic nerve and different severities of visual field defect using optical coherence tomography. Area under the receiver operating characteristic curve (AROC) and sensitivities at fixed specificities were performed for evaluation of diagnostic accuracy of macular and retinal nerve fiber layer parameters. To identify the best optical coherence tomography measurements to differentiate band atrophy of the optic nerve patients from normal individuals, logistic regression models were performed. Association between optical coherence tomography parameters and temporal field defect were examined by Spearman coefficient of correlation. Fisher\'s exact test was performed to evaluate diagnostic ability of retinal nerve fiber parameters by optical coherence tomography in eyes with band atrophy using comparison with its internal normative database. A total of 44 eyes with band atrophy of the optic nerve and 47 normal eyes were studied. Among macular parameters, nasal retina measurements showed diagnostic accuracy better than temporal retina measurements. No statistically significant difference (p=0.32) was found between areas under ROC curve for the best macular parameter (AROC=0.97) and the best retinal nerve fiber layer parameter (AROC=0.99). Nasal retina parameters correlations were higher than retinal nerve fiber parameters. The highest correlation was observed for the mean nasal thickness (rs=0.618) for macular parameters. In retinal nerve fiber parameters, the highest correlation was observed for the average thickness (rs=0.479). In evaluation of diagnostic ability of normative database, the average thickness parameter demonstrated the highest sensitivity for detection of abnormalities in eyes with band atrophy, followed by the parameters related to the nasal and temporal quadrants. These results suggest that macular thickness measurements discriminate eyes with band atrophy of the optic nerve with different severities of temporal field defect. Results also suggest that nasal retina thickness measurements could potentially be used to evaluate retinal ganglion cell loss in patients with chiasmal compression.
44

Quantitative magnetic resonance in diffuse neurological and liver disease /

Dahlqvist Leinhard, Olof, January 2010 (has links)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2010. / Härtill 6 uppsatser.
45

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Felipe de Araujo Andrade Medeiros 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
46

Potencial evocado visual multifocal em olhos com hemianopsia temporal por compressão quiasmática. Correlação com a perimetria computadorizada e a tomografia de coerência óptica / Multifocal visual evoked potential in eyes with temporal hemianopia from chiasmal compression. Correlation with standard automated perimetry and OCT findings

Rafael Miranda Sousa 05 May 2017 (has links)
OBJETIVO: Avaliar a capacidade do potencial visual evocado multifocal (PEV-mf) em diferenciar pacientes portadores de hemianopsia temporal de controles normais e avaliar a correlação entre o PEV-mf, o campo visual (CV) realizado com a perimetria automatizada e a tomografia de coerência óptica de domínio fourier (TCO-dF). MÉTODOS: Vinte sete olhos de 21 pacientes com defeito de campo visual temporal secundário a compressão quiasmática e 43 olhos de 23 controles normais foram submetidos aos exames PEV-mf, CV e TCO-dF (3D OCT-1000®, Topcon) da mácula e da camada de fibras nervosas da retina (CFNR). Foi calculada a média das respostas do PEV-mf global, do PEV-mf central e a média de espessura do TCO-dF da mácula para cada quadrante e para cada hemicampo, enquanto a espessura da CFNR foi dividida em 12 setores ao redor do nervo óptico. A perda de CV foi calculada para os quatro quadrantes e para os hemicampos temporal e nasal no CV 24-2 e CV 10-2. Os dois grupos foram comparados utilizando equações de estimativas generalizadas (GEE) e as correlações entre o PEV-mf, CV e o TCO-dF foram calculadas. RESULTADOS: As médias das amplitude P1 e N2 do PEV-mf global e central para os hemicampos e os quadrantes temporais foram significativamente menores nos pacientes que nos controles (p < 0.004). Não houve diferença estatística entre os grupos para os parâmetros de amplitudes do PEV-mf nos setores nasais. Não houve diferença estatística nas médias das latências do PEV-mf global e central entre os pacientes e os controles normais. Foi encontrada correlação moderada, estatisticamente significativa, entre os parâmetros de amplitudes temporais do PEV-mf - global e central com a perda de CV 24-2 e 10-2 temporal, assim como com as medidas de espessura macular e da espessura CFNR na TCO-dF. CONCLUSÕES: As médias das amplitudes do PEV-mf foram capazes de diferenciar olhos de pacientes com hemianopsia dos controles normais e apresentaram correlação significativa com os dados obtidos pela perimetria automatizada e pelo TCO-dF. Estes dados sugerem que o PEV-mf global e central podem ser utilizados na detecção de anormalidades do campo visual em pacientes portadores de compressão quiasmática / PURPOSE: To evaluate the ability of multifocal visual evoked potential (mfVEP) to differentiate patients with temporal hemianopia due to chiasmal compression from normal controls. To assess the relationship between mfVEP, standard automated perimetry (SAP) and fourier domain-optical coherence tomography (fd-OCT). METHODS: Twenty-seven eyes of 21 patients with permanent temporal visual field (VF) defects from chiasmal compression and 43 eyes of 23 healthy controls underwent mfVEP, SAP and fd-OCT (3D OCT-1000®, Topcon) macular and peripapillary retinal nerve fiber layer (RNFL) measurements. It was averaged the responses for global mfVEP, central mfVEP and fd-OCT macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in 12 sectors around the disc. VF loss was estimated in four quadrants and each half of 24-2 and 10-2 strategy test points. The two groups were compared using generalized estimated equations (GEE). Correlations between mfVEP, VF and fd-OCT findings were verified. RESULTS: Global and central mfVEP P1 and N2 amplitude parameters of temporal measurements were significantly smaller in patients than controls (p < 0.004). No significant differences were observed between the groups with respect to mfVEP amplitude parameters from the nasal measurements. No significant differences were observed in global and central mfVEP latency parameters for all averaged measurements between patients and healthy controls. A significant moderate correlation was found between global and central mfVEP amplitude parameters of temporal measurements and temporal VF 24-2 and 10-2 loss as well as with corresponding fd-OCT macular and RNFL thickness measurements. CONCLUSIONS: mfVEP amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significant correlated with VF and fd-OCT findings. These data suggest that it is a useful technology for detecting visual abnormalities in patients with chiasmal compression
47

Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma / Predictive value of optic disc topography for the development of glaucoma

Luciana Pereira Malta de Alencar 18 July 2011 (has links)
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas / Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
48

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Roberto Murad Vessani 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
49

Neural representations of natural speech in a chinchilla model of noise-induced hearing loss

Satyabrata Parida (9759374) 14 December 2020 (has links)
<div>Hearing loss hinders the communication ability of many individuals despite state-of-the-art interventions. Animal models of different hearing-loss etiologies can help improve the clinical outcomes of these interventions; however, several gaps exist. First, translational aspects of animal models are currently limited because anatomically and physiologically specific data obtained from animals are analyzed differently compared to noninvasive evoked responses that can be recorded from humans. Second, we lack a comprehensive understanding of the neural representation of everyday sounds (e.g., naturally spoken speech) in real-life settings (e.g., in background noise). This is even true at the level of the auditory nerve, which is the first bottleneck of auditory information flow to the brain and the first neural site to exhibit crucial effects of hearing-loss. </div><div><br></div><div>To address these gaps, we developed a unifying framework that allows direct comparison of invasive spike-train data and noninvasive far-field data in response to stationary and nonstationary sounds. We applied this framework to recordings from single auditory-nerve fibers and frequency-following responses from the scalp of anesthetized chinchillas with either normal hearing or noise-induced mild-moderate hearing loss in response to a speech sentence in noise. Key results for speech coding following hearing loss include: (1) coding deficits for voiced speech manifest as tonotopic distortions without a significant change in driven rate or spike-time precision, (2) linear amplification aimed at countering audiometric threshold shift is insufficient to restore neural activity for low-intensity consonants, (3) susceptibility to background noise increases as a direct result of distorted tonotopic mapping following acoustic trauma, and (4) temporal-place representation of pitch is also degraded. Finally, we developed a noninvasive metric to potentially diagnose distorted tonotopy in humans. These findings help explain the neural origins of common perceptual difficulties that listeners with hearing impairment experience, offer several insights to make hearing-aids more individualized, and highlight the importance of better clinical diagnostics and noise-reduction algorithms. </div>
50

Konditionale Inaktivierung von Pten in einem neuen Mausmodell für tomaculöse Neuropathien / Conditional inactivation of Pten in a new mouse model of tomaculous neuropathies

Oltrogge, Jan Hendrik 01 February 2017 (has links)
In der Entwicklung des peripheren Nervensystems formen Schwannzellen eine Myelinscheide um Axone mit einem Durchmesser von mehr als 1 μm durch die Bildung multipler kompakter Membranschichten. Voraussetzung einer optimalen Nervenleitgeschwindigkeit ist dabei ein physiologisches Verhältnis der Dicke der Myelinscheide zu dem jeweiligen Axondurchmesser. Eine zentrale Rolle spielt dabei der axonale EGF-like growth factor NRG1 Typ III, der ErbB2/3- Rezeptoren der Schwannzelle bindet. Der PI3K-AKT-Signalweg ist ein bekannter intrazellulärer Effektor des ErbB2/3-Rezeptors und wurde bereits mit dem Prozess der Myelinisierung in Verbindung gebracht. Um die spezifische Funktion des PI3K-AKT-Signalwegs in Schwannzellen zu erforschen, generierten wir mit Hilfe des Cre/LoxP-Systems Mausmutanten, die eine zellspezifische Inaktivierung des Gens Phosphatase and Tensin Homolog (Pten) in myelinisierenden Gliazellen aufweisen (Pten-Mutanten). Der Verlust der Lipidphosphatase PTEN führte zu einer Anreicherung ihres Substrates, des second messenger Phosphatidyl-(3,4,5)-Trisphosphat (PIP3), und damit zu einer gesteigerten Aktivität des PI3K-AKT-Signalwegs in den Schwannzellen der Pten-Mutanten. Wir beobachteten in den Pten-Mutanten eine ektopische Myelinisierung von unmyelinisierten C- Faser-Axonen sowie eine Hypermyelinisierung von Axonen bis 2 μm Durchmesser. Bei Axonen über 2 μm Durchmesser kam es zu Myelinausfaltungen und fokalen Hypermyelinisierungen (Tomacula) anliegend an Regionen des unkompakten Myelins (Paranodien und Schmidt- Lantermann-Inzisuren). Weiterhin bildeten die mutanten Remak-Schwannzellen unkompakte Membranwicklungen um nicht-myelinisierte C-Faser-Axone und um Kollagenfaserbündel aus („Remak-Myelin“). Sowohl in den Regionen unkompakten Myelins als auch in Remak- Schwannzellen konnte eine erhöhte Aktivität des PI3K-AKT-Signalwegs nachgewiesen werden. Vermutlich setzt die Anreicherung von PIP3 mit Überaktivierung des PI3K-AKT-Signalwegs in den mutanten Gliazellen einen zellautonomen Prozess der Umwicklung von Axonen in Gang. Die zusätzliche Bildung von „Remak-Myelin“ um Kollagenfasern, die keine Membranoberfläche besitzen, weist darauf hin, dass dieser Prozess nicht von einer bidirektionalen axo-glialen Kommunikation abzuhängen scheint. Die beobachteten Tomacula und Myelinausfaltungen zeigten Ähnlichkeiten mit Mausmodellen für hereditäre Neuropathien des Menschen, wie HNPP und CMT4B. Wir vermuten, dass PTEN im unkompakten Myelin unkontrolliertes Membranwachstum verhindert und dass eine gestörte Balance von Phosphoinositiden einen Pathomechanismus von tomaculösen Neuropathien darstellt. Somit identifizieren wir den PI3K-AKT-Signalweg als ein mögliches Ziel zukünftiger Therapiekonzepte für hereditäre Neuropathien des Menschen.

Page generated in 0.4535 seconds