• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 789
  • 220
  • 83
  • 54
  • 35
  • 15
  • 14
  • 11
  • 11
  • 11
  • 6
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 1395
  • 496
  • 385
  • 205
  • 184
  • 162
  • 162
  • 154
  • 147
  • 143
  • 135
  • 113
  • 110
  • 103
  • 102
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

"Estudo da influência do tratamento por calor em propriedades mecânicas de resinas compostas" / Influence of heat treatment on the mechanical properties of resin composites

Santana, Ivone Lima 08 December 2005 (has links)
O objetivo deste trabalho foi o de avaliar o efeito de tratamentos por calor nas propriedades mecânicas de resistência flexional e microdureza Knoop de três marcas comerciais de resinas compostas para uso direto (FillMagic, P60 e TPH), na condição de incluída ou não em revestimento durante um tratamento térmico (calor seco/170°C), por três períodos (5, 10 e 15 min). A temperatura adotada para os tratamentos foi baseada em análises prévias (termogravimetria e calorimetria exploratória diferencial) com a finalidade de se determinar a temperatura de início de perda de massa e de transição vítrea das resinas. Os corpos-de-prova (n=7) foram confeccionados com o auxílio de uma matriz metálica (10 mm x 2 mm x 2 mm), sendo o compósito inserido em bloco único e irradiado numa única superfície (600mW/cm 2 por 40s). Foram obtidos, no total, sete grupos experimentais por resina, sendo o controle a condição de apenas fotoativada. Os espécimes foram submetidos ao ensaio de resistência à flexão, com distância entre apoios de 8 mm, em uma velocidade constante de 0,5 mm/min e célula de carga de 1000N. A dureza Knoop foi obtida com carga de 100 g e tempo de penetração de 15 s. As médias de resistência flexional, em MPa, foram de 174,80 para a resina FillMagic, 182,64 para a P60 e 172,22 para a TPH. Na mesma ordem, as médias de microdureza Knoop foram de 73,1; 102,0 e 74,0.A análise de variância dos resultados obtidos permitiram concluir que os tratamentos experimentais aumentaram a resistência flexional das resinas indistintamente. Os valores de microdureza também aumentaram, mas houveram diferenças de suscetibilidade ao tratamento térmico entre as resinas / The aim of this study was to assess the effect of heat treatment on mechanical properties of flexure strength and Knoop micro hardness of three commercially available brands of resin composites for direct use (FillMagic, P60 and TPH) included or not in investments during heat treatment (dry heat/170ºC) by three periods (5, 10 and 15 min.) The temperature adopted for the treatments was based on previous analysis (thermo gravimetric and differential exploratory heating) in order to determine the initial temperature of mass loss and glass transition of resin composites. The samples (n=7) were prepared with a metallic matrix (10 mm x 2mm x 2mm) in which the resin composite was inserted in a single block and only one surface was irradiated (600mW/cm 2 40s). Seven experimental groups were obtained for each resin composite in which the control group was solely light-cured. The flexure strength test was performed with a support distance of 8 mm, cross-head speed of 0.5 mm/min. and 1000 N load. Knoop micro hardness was obtained with a load of 100 g and penetration time of 15 s. The flexure strength averages in MPa were 174.80 for FillMagic, 182. 64 for P60 and 172. 22 for TPH. Thus, Knoop micro hardness means were 73.1; 102.0 and 74.0. The analysis of variance indicated that the experimental treatments increased flexure strength of resin composites. Micro hardness values also increased, but there were differences in the resin composites susceptibility to the heat treatment
372

Análise da qualidade da polimerização e da degradação de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro por meio de testes de microdureza / Microhardness analysis of the polymerization quality and degradation of resin cements used for fiber posts cementation

Pedreira, Ana Paula Ribeiro do Vale 16 April 2007 (has links)
Os cimentos resinosos têm sido largamente utilizados em odontologia restauradora com a finalidade de reter o pino intra-radicular e dissipar tensões entre este e a raiz. Entretanto, o grau de conversão alcançado pelos mesmos influencia suas propriedades mecânicas, biocompatibilidade e degradação pela água e pelos ácidos bucais. Testes de microdureza podem ser aplicados para estimar o grau de conversão de compósitos, uma vez que apresentam boa correlação com a espectroscopia infravermelha. Este trabalho objetivou analisar a microdureza de quatro cimentos resinosos de polimerização dual utilizados na cimentação de pinos de fibra de vidro, nos períodos inicial, após 24 horas de imersão em etanol a 75% e após 3 meses de armazenamento em água, e testar a hipótese de que não há diferença entre a microdureza dos terços cervical, médio e apical na linha de cimento. Quarenta incisivos bovinos tratados endodonticamente foram distribuídos em quatro grupos para a cimentação de pinos Fibrekor® (Jeneric/Pentron) de 1mm de diâmetro, sendo: Grupo 1 - Panavia F 2.0 (Kuraray Medical Inc.), Grupo 2 - Variolink (Ivoclar), Grupo 3 - Rely X Unicem (3M ESPE) e Grupo 4 - Duolink (Bisco). Após a cimentação, as raízes foram divididas em 2 subgrupos, sendo 5 seccionadas após 7 dias para análise da microdureza inicial e 5 mantidas íntegras em água deionizada por 3 meses, para avaliação da microdureza final no microdurômetro Shimadzu HMV (Japan). Após a mensuração inicial, as raízes seccionadas eram armazenadas a 37º C por 24h em 10mL de solução de etanol a 75%, e reavaliadas. Foram identificadas diferenças estatisticamente significativas entre cimentos, terços e períodos (inicial ou após 24h de imersão em etanol a 75%), bem como interações entre cimento/terços e cimento/períodos de avaliação. O cimento Panavia exibiu os valores de microdureza inicial significativamente superiores, sem diferença estatística entre os demais cimentos. Os valores de microdureza inicial por terços não seguiram um padrão homogêneo; os cimentos Variolink e Duolink exibiram valores de microdureza significativamente superiores no terço cervical, sem diferença significativa entre os terços para os demais cimentos. A imersão em etanol reduziu significativamente a média dos valores de dureza para todos os cimentos; o comportamento por terços variou em função do material. O armazenamento em água por 3 meses não exerceu influência sobre a dureza da maioria dos cimentos, com exceção do Unicem, que exibiu aumento significativo dos valores de dureza após esse período. Portanto, a hipótese proposta neste estudo foi rejeitada. / Resin cements have been largely used in dentistry for retaining intraradicular posts and to minimize tension between them. However, the degree of conversion influences mechanical properties, biocompatibility and susceptibility of water and acid degradation of these polymers. Hardness tests are used to estimate the degree of conversion of composites, as it shows good correlation with infrared spectroscopy. The aim of this study was to evaluate the microhardness of four resin cements used for fiber posts cementation at the nitial period, 24h-immersion in a 75% ethanol solution and after 3-month water storage. Forty bovine incisives were endodontically treated and restored with 1mm diameter Fibrekor® posts (Jeneric/Pentron), being: Group 1 - Panavia F 2.0 (Kuraray Medical Inc.), Group 2 - Variolink (Ivoclar), Group 3 - Rely X Unicem (3M ESPE) and Group 4 - Duolink (Bisco). After cementation, each group was divided in two subgroups: 5 roots were sectioned 7 days after cementation for initial hardness measurement and 5 roots were immersed in deionized water for 3 months for final hardness measurements using Shimadzu Micro Hardness Tester (HMV, Japan). After the initial measurements, the sectioned roots were immersed in 10mL 75% ethanol solution for 24h at 37ºC, and tested again. Differences in hardness values have been detected among resin cements, radicular thirds and periods (initial or 24h-immersion in a 75% ethanol solution). Data also revealed significant interaction to cement/third and cement/period of evaluation. Panavia showed higher hardness values, with no statistical differences among the other cements. It was not verified a homogeneous pattern regarding radicular third; Variolink and Duolink exhibited higher hardness values for the cervical third, without differences among radicular thirds for the other cements. Hardness values decreased after ethanol immersion for all resin cements and the hardness according to radicular thirds varied among the materials. The hardness of tested resin cement showed no influence after 3-month water storage, except for Unicem as it showed an increase in Knoop hardness after this period. Therefore, the null hypotesis proposed was rejected.
373

Influência da espessura da cerâmica, do tempo de fotopolimerização e do cimento resinoso na resistência de união à microtração de uma cerâmica vítrea cimentada à dentina humana /

Barca, Diana Capelli. January 2010 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Henrique Cerveira Netto / Banca: Rodrigo Othavio de Assunção e Souza / Resumo: Este estudo avaliou a influência da espessura da cerâmica, do tempo e tipo de fotopolimerização do cimento resinoso na resistência da união entre uma cerâmica vítrea e a dentina coronária humana. A hipótese é a de que o tipo e o tempo de fotopolimerização do agente cimentante e a espessura da cerâmica influenciem na resistência de união entre cimento e dentina. Foram selecionados cento e doze dentes molares humanos hígidos que foram incluídos em resina acrílica e tiveram a superfície oclusal cortadas em máquina Labcut, expondo a dentina planificada. Dois grupos foram tiveram a dentina condicionada com ácido fosfórico 37% lavada e aplicado adesivo (Excite, Ivoclar) fotopolimerizando por 20s. No grupo controle (n=16), utilizou-se cimento auto-adesivo. Foram confeccionados cento e doze blocos (6 x 6 mm) de cerâmica feldspática (Vita PM9) com três espessuras: 1, 2 e 3 mm que tiveram a superfície de cimentação tratad a com ácido fluorídrico 10%, lavada, seca e silanizada. Os blocos cerâmicos foram cimentados, de acordo com o grupo experimental: Variolink II (Ivoclar Vivadent); e fotopolimerizados com LED por 40 ou 80 segundos de fotopolimerização ou cimento Multilink II (no grupo controle). Assim, formaram-se sete grupos (n=16). Os espécimes foram armazenados em água destilada (37°C) por 24 horas e seccionados em dois eixos, X e Y, para a obtenção dos espécimes. Cada grupo (N=16) foi subdividido em 2 (n=8) onde um grupo foi termociclado e o outro submetido ao ensaio de microtração 24 horas após a cimentação. Esse palito (cerâmica/dente) foi fixado no dispositivo de microtração Erios, levado à máquina de ensaio universal e testado com velocidade de 1 mm/min. Os valores médios obtidos (MPa) foram à análise de Variáveis ANOVA 3- fatores, teste de Dunnett e ao teste de Tukey (5%). A resistência adesiva foi significantemente influenciada pelos fatores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the influence of the thickness of the ceramic, time and type of light curing resin cement on bond strength between a ceramic and glass human dentin. The hypothesis is that the type and time of curing luting agent and the thickness of the ceramic bearing on the bond strength between cement and dentin. We selected one hundred and twelve healthy human molar teeth were embedded in acrylic resin and were cut in the occlusal surface Labcut machine, exposing the dentin. Two groups have had to dentin conditioned with 37% phosphoric acid washed applied adhesive (Excite, Ivoclar) light cured for 20s. In the control group (n = 16), we used self-adhesive cement. We made one hundred and twelve blocks (6 x 6 mm) ceramic feldspathic (Vita PM9) with three thicknesses: 1, 2 and 3 mm that had cement surface treated with hydrofluoric acid 10%, washed, dried, and silanized. The ceramic blocks were cemented according to the experimental group: Variolink II (Ivoclar Vivadent) and cured with LED for 40 or 80 seconds of curing cement Multilink or II (control group). Thus, they formed seven groups (N = 16). The specimens were stored in distilled water (37 ° C) for 24 hours and sectioned in two axes, X and Y, to obtain the specimens. Each group (N = 16) was subdivided into two (n = 8) where a group was thermocycled and another test by microtensile 24 hours after cementation. This toothpick (ceramic / tooth) was mounted in microtensile Erios, led to a universal testing machine and tested at a speed of 1 mm / min. The average values (MPa) were the ANOVA analysis of three variables - factors, Dunnett test and Tukey test (5%). The bond strength was significantly influenced by light irradiation time, thickness of the ceramic thermal cycling / Mestre
374

Cimentação de laminados cerâmicos : efeito de diferentes modos de fotoativação na estabilidade de cor e nas propriedades mecânicas de sistemas adesivos e cimentos resinosos /

Sahyon, Henrico Badaoui Strazzi. January 2017 (has links)
Orientador: Paulo Henrique dos Santos / Banca: Wirley Gonçalves Assunção / Banca: Anderson Catelan / Resumo: O objetivo deste estudo in vitro foi avaliar os efeitos de diferentes modos de fotoativação na nanodureza e módulo de elasticidade de sistemas adesivos e cimentos resinosos, assim como o efeito na estabilidade de cor de laminados cerâmicos. Os fatores em estudos foram: dois níveis de fotopolimerizadores (VALO - Ultradent; Radii-Cal - SDI) e três níveis de modo de ativação (sem polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico; polimerização prévia do sistema adesivo somente na superfície dental; e polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico). Na análise da estabilidade de cor o terceiro fator estudado foi o tempo de envelhecimento (252, 504 e 756 horas). Foram confeccionados 132 blocos de cerâmica (7x8x0,6mm) de dissilicato de lítio (IPS e-max CAD), os quais foram cimentados sobre o esmalte dentário dos dentes bovinos, distribuídos em 12 grupos de acordo com os materiais restauradores e métodos de procedimentos utilizados. Dois sistemas adesivos e cimentos resinosos foram utilizados (Single Bond Universal/RelyX Veneer- 3M/ESPE e Tetric N Bond/Variolink Veneer - Ivoclar Vivadent). As propriedades mecânicas de nanodureza e módulo de elasticidade foram mensuradas utilizando nanodurômetro (Anton Paar), sob ação de carga de 1000μN (n=3). A estabilidade de cor foi mensurada através do espectrofotômetro de reflexão ultravioleta visível UV-2450 (Shimadzu) antes e após a submissão das amo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this in vitro study was to evaluate the effects of different modes of photoactivation in the nanohardness and elastic modulus of resin cements and adhesives, as well as the effect on the color stability of ceramic laminates. The factors of the studies were: two levels of light curing units (VALO - Ultradent; Radii-Cal - SDI) and three modes of photoactivation (without prior curing of the adhesive system in the tooth surface and inside of the ceramic laminate, prior curing the adhesive system only in the tooth surface, and prior curing of the adhesive system in the tooth surface and within the ceramic laminate). In the analysis of color stability the third factor of the study was the aging time (252, 504 and 756 hours). One hundred and thirty two ceramic blocks (7x8x0.6mm) of lithium dissilicate (IPS e-max CAD) were made, which were cemented on the enamel of bovine teeth, and distributed into 12 groups according to the restorative materials (Single Bond Universal/RelyX Veneer - 3M/ESPE and Excite DSC/Variolink Veneer - Ivoclar Vivadent) and methods of procedures. The mechanical properties of nanohardness and elastic modulus were measured using a nanohardness tester (Anton Paar) under loaf of 1000 μN (n=3). Color stability was measured using a UV-2450 visible UV spectrophotometer (Shimadzu) before and after the submission of the UVB artificial accelerated aging samples (n=8). Data of color stability and mechanical properties were submitted to statistical testes o... (Complete abstract click electronic access below) / Mestre
375

Recuperação de níquel e cobalto a partir de lixiviado de níquel laterí­tico utilizando resinas quelantes e processo de pré-redução. / Recovery of nockel and cobalt from nickel laterite leach solution using chelating resins and pre-reducing process.

Amilton Barbosa Botelho Junior 13 December 2018 (has links)
Níquel laterítico compõe 70% das reservas disponíveis do metal. A produção de níquel a partir dessas reservas representa 40%, dos quais é possível extrair também cobre e cobalto. Isso ocorre devido ao alto teor de impurezas, principalmente ferro. Com a crescente demanda desses metais, o uso das reservas de lateritas de níquel passou a ser mais profundamente investigado, assim como o desenvolvimento de processos hidrometalúrgicos. Nesse caso, o íon férrico prejudica a recuperação do níquel e do cobalto, uma vez que em trocas iônicas esse metal compete na ocupação dos sítios catiônicos. Em processos de extração por solvente um efeito semelhante é observado. Além disso, durante a eventual precipitação do ferro ocorre a coprecipitação. Assim, para a troca iônica, o íon ferroso pode ser menos prejudicial do que o férrico. O presente trabalho teve por objetivo o estudo do processo de redução do íon férrico em solução aquosa, e também a posterior obtenção de cobalto e níquel por meio de resinas quelantes. Estudou-se o processo de redução do íon férrico e o efeito na adsorção de metais por troca iônica. Os ensaios de redução química do íon férrico em solução foram estudados utilizando ditionito de sódio, metabissulfito de sódio e sulfito de sódio. Os ensaios com os agentes redutores ditionito e metabissulfito de sódio foram feitos em São Paulo, e os ensaios com o sulfito de sódio foram feitos na The University of British Columbia. Os agentes redutores foram adicionados na solução monoelementar de ferro para redução do potencial redox. As variáveis potencial redox, entre 860mV e 240mV; pH, entre 0,5 e 3,5; temperatura, entre 25°C e 60°C; e tempo, entre 30min e 96 horas, foram estudadas em frascos erlenmeyer sob agitação constante. Analisou-se, então, a redução do íon férrico em solução multielementar de níquel laterítico. Nos ensaios de troca iônica, realizados em batelada e em coluna, utilizou-se a resina quelante Lewatit TP 207, de grupo funcional iminodiacetato, e a resina Lewatit TP220, de grupo funcional bis-picolilamina. Três soluções foram estudadas: uma preparada com Fe(III), outra com Fe(II) e a terceira com Fe(III) após o processo de pré-redução. Os ensaios em batelada foram realizados com a utilização de frascos erlenmeyer, sob agitação constante, com 100mL de solução para 1mL de resina. Estudou-se o efeito do pH, entre 0,5 e 3,5; tempo, entre 30min e 480min; e temperatura, entre 25°C e 60°C. Nos ensaios em sistema contínuo, as três soluções foram alimentadas em colunas de vidro preenchidas com resina. A solução foi alimentada com bombas peristálticas a vazão constante. Para eluição das colunas, ácido sulfúrico 1mol.L-1 foi alimentado na coluna com utilização de bomba peristáltica. A segunda parte do trabalho, realizado na The University of British Columbia, foi o estudo do uso de sulfito de sódio no processo de pré-redução. Foram estudadas duas resinas: a Lewatit TP 207, seletiva para cobre; e a Lewatit TP 220, seletiva para níquel e cobalto. O sulfito de sódio foi adicionado na solução para redução do potencial, em frascos, e colocado sob agitação constante. Após reação, as soluções foram colocadas em contato com a resina quelante, e ficaram em agitação. Os ensaios em batelada foram realizados e o efeito do pH estudado entre 0,5 e 3,5. No processo em coluna, a Coluna 1, preenchida com a resina Lewatit TP 207, foi utilizada para remoção do cobre; e a solução de saída foi alimentada na Coluna 2, preenchida com a resina Lewatit TP 220. Para a eluição, foram estudados os ácidos clorídricos e sulfúricos em duas diferentes concentrações, 1mol.L-1 e 2mol.L-1. Hidróxido de sódio foi utilizado para remover o ferro na solução obtida na saída da Coluna 2. A separação do cobalto da solução foi feita utilizando a técnica de extração por solventes (Cyanex 272 20%), estudando o efeito do pH, 4,0 e 5,0, e da temperatura, 25°C e 65°C. Os resultados mostraram que a redução do íon férrico utilizando ditionito de sódio foi de 100% na solução monoelementar e de 70% na multielementar contendo os outros metais. Nos ensaios de troca iônica em batelada, utilizando a resina TP 207, 62% do cobre foi adsorvido na solução após processo de pré-redução. Para solução com Fe(II), a adsorção de cobre foi de 61%; e para solução com Fe(III), 49%. Nos ensaios de troca iônica após pré-redução do ferro com sulfito de sódio, a adsorção do cobre foi de 69% em pH 2,0 pela resina TP 207. A resina TP 220 foi mais seletiva para níquel e cobalto em pH 2,0, em que as adsorções destes metais foram 32,5% e 69%, respectivamente. Nos ensaios em coluna, a Coluna 1 foi utilizada para remoção de cobre, porém houve perda de 17% de níquel e 7% de cobalto. Na alimentação da Coluna 2, verificou-se que 98% do níquel e 84% do cobalto foram adsorvidos. A solução obtida da Coluna 2 teve concentração de 618mg.L-1 de ferro, 13231mg.L-1 de níquel e 179mg.L-1 de cobalto. A remoção de 100% do ferro foi possível em pH 4,0. Para separação do cobalto da solução rica em níquel, utilizou-se a extração por solventes com o Cyanex 272 20% em querosene, no qual 99% do cobalto foi separado da solução a 65°C e pH 5,0, sem perda de níquel. Para estudos futuros, a remoção do cobre no início do processo pode ser explorada com a utilização de outras técnicas, a fim de se evitarem perdas de níquel e cobalto. Outro ponto que pode vir a ser explorado é a máxima utilização das colunas de troca iônica nas mesmas condições deste trabalho - solução com Fe(III), com Fe(II) e após processo de pré-redução - sobretudo em escala piloto, para estudar o efeito do estado de oxidação do ferro em um possível envenenamento da resina. / Nickel laterite ores represent 70% of the available metal reserves. The nickel production from these reserves represents 40%, where it is also possible extract copper and cobalt. It occurs due to the high impurities content, mainly iron. With the growing demand of these metals, the use of nickel laterite reserves became more deeply investigated, as well as hydrometallurgical process development. In this case, the ferric iron difficult the nickel and cobalt recovery, once in ion exchange processes this metal competes in the occupation of the cationic sites. In solvent extraction processes the same effect is observed. Besides that, during the eventual iron precipitation there is a co-precipitation. Therefore, for ion exchange, ferrous iron may be less damaging than ferric iron. The aim of this work was to study the reducing process of ferric iron in aqueous solution, and also the subsequent obtaining of cobalt and nickel through chelating resins. It was studied the reducing process of ferric iron and the effect of it in metals adsorption by ion exchange. Experiments of chemical reduction of ferric iron in solution were studied using sodium dithionite, sodium metabisulfite and sodium sulfite. Experiments with reducing agents sodium dithionite and metabisulfite were performed in São Paulo, and experiments with sodium sulfite were performed in The University of British Columbia. Reducing agents were added in ferric iron mono-elementary solution to decrease the redox potential. The variables potential redox, between 860mV and 240mV; pH, between 0,5 and 3,5; temperature, between 25°C e 60°C; and time, between 30min and 96 hours were studied in erlenmeyer flasks under constant stirring. Then, analyzed ferric iron reduction in multielementary solution of nickel laterite. In ion exchange experiments, performed in batch and column, it was used chelating resin Lewatit TP 207, with iminodiacetate functional group, and resin Lewatit TP 220, with bis-picolylamine functional group. Three solutions were studied: prepared with Fe(III), other with Fe(III) and the third with Fe(III) after pre-reducing process. Experiments in batch system were performed using erlenmeyer flasks, under constant stirring, with 100mL of solution to 1mL of resin. It was studied the effect of pH, between 0,5 and 3,5, time, between 30min and 480min, and temperature, between 25°C e 60°C. In experiments in continuous system, the three solutions were fed in glass columns filled with resin. The solution was fed using peristaltic pumps at constant flow rate. For column elution, sulfuric acid 1mol.L-1 was fed to the column using peristaltic pumps. The second part of this work, performed at The University of British Columbia, was the study of sodium sulfite application at prereducing process. It was studied two resins: Lewatit TP 207, selective for copper, and Lewatit TP 220, selective for nickel and cobalt. Sodium sulfite was added to the solution to decrease the potential, in flasks and it was placed under constant stirring. After reaction, the solution was placed in contact to the chelating resin, which was placed under stirring. Batch experiments were performed, and the effect of pH was studied between 0,5 and 3,5. In column process, the Column 1, filled with Lewatit TP 207, was used for copper removal, and output solution was feed in Column 2, filled with Lewatit TP 220. For the elution, it was studied sulfuric and hydrochloric acids in two different concentrations, 1mol.L-1 e 2mol.L-1. Sodium hydroxide was used for iron removal from solution obtained in Column 2 output. Cobalt separation was performed using solvent extraction technique (Cyanex 272 20%), studying the effect of pH, 4,0 and 5,0, and temperature, 25°C e 65°C. Results shows that ferric iron reduction using sodium dithionite was 100% in mono-elementary solution and 70% in multi-elementary solution with other metals. In ion exchange experiments performed in batch using resin TP 207, 62% of copper was adsorbed by the resin after pre-reducing process. For solution with Fe(II), the copper adsorption was 61%, and for solution with Fe(III), 49%. In ion exchange experiments after pre-reducing process using sodium sulfite, the copper adsorption was 69% at pH 2,0 by the resin TP 207. The resin TP 220 was more selective for nickel and cobalt at pH 2,0, where these metals adsorptions were 32,5% and 69%, respectively. In experiments performed in column, the Column 1 was used for copper removal, however there were losses of nickel (17%) and cobalt (7%). In the feeding of Column 2, it was found that 98% of nickel and 84% of cobalt were adsorbed. Solution obtained in Column 2 had concentration of iron 618mg.L-1, nickel was 13231mg.L-1 and cobalt 179mg.L-1. The iron removal was 100% at pH 4,0. For cobalt separation in nickel-rich solution, it was used the solvent extraction with Cyanex 272 20% with kerosene, where 99% of cobalt was separated from solution at 65°C and pH 5,0, without nickel loss. For future studies, the copper removal in the beginning of the process can be explored using other techniques, in order to avoid nickel and cobalt losses. Another point that can be explored is the maximum use of ion exchange columns in the same conditions of this work - solution with Fe(III), with Fe(II) and after the pre-reducing process - mostly on a pilot scale, to study the effect of iron oxidation state on possible resin poisoning.
376

INFLUÊNCIA DA INCORPORAÇÃO DE UM PLASTIFICANTE E UM POLIETILENO DE ALTO PESO MOLECULAR NAS PROPRIEDADES DE UMA RESINA EXPERIMENTAL E DIMINUIÇÃO DO ESTRESSE DE CONTRAÇÃO / Influence of the incorporation of a plasticizer and high molecular weight polyethylene on the properties of an experimental resin and shrinkage stress decrease.

Dominguez, John Alexis 13 August 2015 (has links)
Made available in DSpace on 2017-07-24T19:22:03Z (GMT). No. of bitstreams: 1 John Alexis Domingues.pdf: 1971333 bytes, checksum: 6d76db539da045af70dd08f004b5c7c8 (MD5) Previous issue date: 2015-08-13 / The objectives of this study were: 1) to evaluate the degree of conversion, shrinkage stress, flexural and compressive strength of an experimental resin with a lactic polyacid and castor oil; 2) to evaluate the cytotoxicity of an experimental resin with a lactic polyacid, and castor oil; 3) evaluate, degree of conversion, shrinkage stress, flexural and compressive strength an experimental resin with addition of a high molecular weight polyethylene; 4) to assess the cytotoxicity of an experimental resin with addition of a high molecular weight polyethylene. Initially, it was synthesized a poly (lactic acid) (PLA) via a polycondensation process. After 24 hours, the castor oil (OR) was incorporated by an esterification process with N, N-Dicyclonecylcarbodimide and 99% 4-Dimethylamino-Pyridine in 40 mL of tetrahydrofuran. After this, the blend was characterized by X-ray diffraction (XRPD), Raman spectroscopy, scanning electron microscopy (SEM) and shrinkage stress, where was proven the incorporation of PLA + OR in the experimental composite resin. In the third chapter, PLA + OR were manipulated in two concentrations (1.5% and 3%) in an experimental composite: (2,2 bis [4- (2-hydroxy-3-metacrilatoxypropoxy) phenol] (BisGMA) Triethylene glycol dimethacrylate (TEGDMA), camphorquinone (CQ), N, N-dimethylaminoethyl methacrylate (DEMA-EMA), butylated hydroxytoluene (BHT), silanated barium borosilicate glass, and the tests of degree of conversion, compressive and flexural strength and shrinkage stress were made. The cytotoxicity assay was done; a suspension of 3 x 103 cells/mL of culture medium was prepared. For this, the cells were detached from the bottom of the bottle by the addition of trypsin with EDTA, after incubation in 5% CO2 with 3 mL Eagle's medium supplemented culture. After 24 h incubation period, the culture medium was removed and 200 uL of a solution of culture medium and methylltetrazolium salt (MTT). Subsequently, the analysis of mitochondrial activity was performed in a spectrophotometer (Biotek EL 800, Biotek, Winooski, VT, USA) with a 10 wavelength of 570 nm. The data from each test were analyzed by one-way ANOVA. No significant differences were found (p <0.005) in compressive and degree of conversion tests, and significant differences in shrinkage stress where obtained, up to 69% decrease. and flexion, statistically significant . In the fourth chapter, it was incorporated a high molecular weight polyethylene and polypropiylene, in the experimental resin proposed in chapter two, at two concentrations (1.5% and 3%), and tested by degree of conversion, compressive and flexural strength and shrinkage stress. The data from each test were analyzed by one way ANOVA, finding no significant difference (p> 0.005) in degree of conversion, compressive and flexural strength, and the contraction stress showed a significant reduction of up to 40%. Conclusion: PLA + castor oil and the high molecular weight polyethylene decreases the shrinkage stress and properties like flexural and compressive strength and degree of conversion were not influenced. / Os objetivos deste estudo foram: 1) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com um poliácido lático e óleo de rícino; 2) avaliar a citotoxicidade de uma resina experimental com um poliácido lático e óleo de rícino; 3) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com adição de um polietileno de alto peso molecular e 4) avaliar a citotoxicidade de uma resina experimental com adição de um polietileno de alto peso molecular. Previamente realizou-se a síntese de um Poli-ácido lático (PLA) por meio de um processo de policondensação. Após 24 horas, foi incorporado o óleo de rícino (OR) por meio de um processo de esterificação junto a N,N-Diciclonecilcarbodimida e 4-Dimetilamino-Piridina a 99% em 40 mL de tetrahidrofeurano. Em seguida, o conjunto foi caracterizado por difração de espectroscopia Raman, microscopia eletrônica de varredura (MEV) e estresse de contração, onde foi comprovada a incorporação do PLA+OR numa resina composta experimental. No terceiro capítulo foi feita a incorporação do PLA+OR em duas concentrações (1,5% e 3%) numa resina composta experimental: (2,2 bis[4-(2-hidroxi-3-metacrilatoxipropoxi)fenol](BisGMA), Trietilglicoldimetacrilato (TEGDMA), canforoquinona (CQ), N,N– dimetilaminoetil metacrilato (DMAEMA), hidroxitolueno butilado (BHT), vidro de borossilicato de bário silanizado e foram realizados os testes de flexão, compressão, grau de conversão e estresse de contração. Foi feito o teste de citotoxicidade, uma suspensão de 3 x 103 células/mL de meio de cultura foi preparada. Para isso, as células foram descoladas do fundo da garrafa por meio da adição de tripsina com EDTA, após incubação em estufa com 5% de CO2 e 3 mL de meio de cultura Eagle suplementado. Após o período de incubação de 24 h, o meio de cultura foi removido e 200 μL de uma solução de meio de cultura e sal metiltetrazólio (MTT).Posteriormente, a análise da atividade mitocondrial foi realizada em espectrofotômetro (Biotek EL 800, Biotek, Winooski, VT, EUA) com comprimento de onda de 570 nm. Os dados obtidos de cada teste foram analisados com ANOVA um fator. Não encontrou-se diferença significativa (p> 0.005) nos testes de compressão e grau de conversão; já para o teste de estresse de contração, houve diminuição estatisticamente significativa de até 69% e no teste de resistência à flexão . No quarto capítulo foi feita a incorporação de um polipropileno (PP) e o polietileno de ultra-alto peso molecular (UTEC) a uma resina experimental com os mesmos materiais manipulados no capítulo dois, em duas concentrações (1,5% e 3%), e realizados os testes de compressão, flexão, grau de conversão e estresse de contração. Os dados de cada teste foram analisados com ANOVA um fator. Não houve diferença significativa (p> 0.005) nos testes de compressão, flexão e grau de conversão; já para o teste de estresse de contração houve diminuição estatisticamente significativa de até 40%. Conclusão: OPLA+óleo de rícino e o polietileno de ultra alto peso molecular em 1,5%, diminuíram o estresse de contração e propriedades como resistência à flexão, compressão e grau de conversão não foram influenciadas.
377

Avaliação da dureza superficial de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro

Grande, Fernanda Zander 21 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:11Z (GMT). No. of bitstreams: 1 Fernanda Zander.pdf: 940456 bytes, checksum: 47429e6712305973cd3b486e5ac590f1 (MD5) Previous issue date: 2006-02-21 / The purpose of this study was to investigate the interaction between two methods of adhesive systems activation (chemically cured and dual cured) and two methods of resin cements activation (chemically cured and dual cured) in Vickers microhardness values of resin cements, in differents depths of cure and differents distances of the adhesive systems used. There were 50 bovin inferior incisives which had their crowns transversaly crosscuted to use the root portion. The canal roots were prepared to the fiber posts cementation. The teeth were randomly divided in five groups: I) Adhesive system Prime & Bond 2.1 with Self Cure Activator and dual resin cement EnForce; II) Adhesive system Prime & Bond 2.1 and dual resin cement EnForce; III) ED Primer and chemically cured resin cement Panavia 21; IV) Adhesive system Clearfil SE Bond and chemically cured resin cement Panavia 21 e V) Adhesive system Prime & Bond 2.1 with Self Cure Activator and dual resin cement EnForce. In group V The EnForce wasn’t light-cured standing only with the chemically activation. After posts cementation the roots were cuted in 3 portions with 3 mm eatch (cervical, medium and apical) and after 7 days the specimens were tested. The specimens were divided in quadrants that recived 2 identations, one next the fiber post and other next the canal root surface. Data were submitted to threeway ANOVA and Tukey’s test. The application of these tests revealed statistically significant differences for the variables: group, position, region; interaction between group and position (p< 0,001), and interaction between group and region (p= 0,041). There weren’t, however, statistically significant differences interaction between position and region (p= 0.85). The conclusions were: the superficial hardness, independently of the kind of cement and adhesive system was always present in all regions of root canal; the chemically cured resin cement demonstrated the higher values of hardness; the factor depth of cure interfered in superficial hardness values in all groups, being more evident in GI and GII than GIII, GIV e GV; there was interference of adhesive systems in microhardness values for all groups, what can be observed in smaller values found next the adhesive systems. It was more evident in GIV that used the self-etched adhesive system and less evident in GIII that used ED Primer. The findings of this study demonstrates that the pH of adhesive systems inluences the microhardness values of resin cements. / O objetivo deste trabalho foi analisar a interação de dois tipos de ativação de sistemas adesivos (fotoativável e ativação dual) e dois tipos de ativação de cimentos resinosos (ativação química e ativação dual) nos valores de microdureza Vickers dos cimentos em diferentes profundidades de polimerização e diferentes proximidades com o sistema adesivo utilizado. Foram utilizados 50 incisivos bovinos inferiores que tiveram suas coroas seccionadas transversalmente para a utilização da porção radicular. Os condutos radiculares foram preparados para a cimentação de pino de fibra de vidro. Os dentes foram divididos aleatoriamente em cinco grupos: I) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce; II) Sistema adesivo Prime & Bond 2.1 e cimento resinoso dual EnForce; III) ED Primer e cimento resinoso químico Panavia 21; IV) Sistema adesivo Clearfil SE Bond e cimento resinoso químico Panavia 21 e V) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce. No grupo V o cimento EnForce não foi fotoativado ficando apenas com a ativação química. Após a cimentação dos pinos as raízes foram então seccionadas em três secções de 3 mm de espessura (cervical, média e apical) e após sete dias foi feita a análise da microdureza Vickers. As secções de cada terço foram divididas em quadrantes iguais e em cada quadrante foram realizadas duas identações, sendo uma próxima ao pino de fibra de vidro e a outra próxima à parede do conduto radicular. Os resultados foram submetidos à análise estatística ANOVA três critérios, havendo diferença estatística entre os grupos foi feito o teste de Tukey para a comparação dos grupos dois a dois. A aplicação do teste de Análise de Variância à três critérios revelou haver diferenças estatisticamente significantes para as variáveis independentes: grupo, posição, região, interação entre grupo e posição (p<0,001), e interação entre grupo e região (p=0,041), não havendo, contudo, diferença estatisticamente significante para as interações entre posição e região (p=0,983) e para a interação entre grupo, posição e região (p=0,85). Concluiu-se que: a dureza superficial, independente do tipo de cimento e dos sistemas adesivos esteve sempre presente em todas as regiões analisadas do canal radicular; o cimento resinoso quimicamente ativado (GIII) apresentou maiores valores de dureza superficial quando comparado ao cimento resinoso de dupla ativação, independente da região analisada do canal radicular; o fator profundidade de polimerização interferiu nos valores de dureza superficial em todos os grupos, sendo mais evidente para os grupos onde o cimento foi fotoativado (GI e GII) do que para os grupos com ativação química (GIII, GIV e GV) que mostraram maior uniformidade nos três terços do conduto radicular; Houve interferência dos sistemas adesivos utilizados nos valores de microdureza para todos os grupos, o que pode ser observado nos menores valores encontrados próximo aos sistemas adesivos, sendo mais evidente no GIV que utilizou o sistema adesivo autocondicionante e menos evidente no grupo III que utilizou o Primer do próprio cimento, mostrando a incompatibilidade entre os sistemas adesivos com menor pH e a fase quimicamente ativada dos cimentos resinosos. O objetivo deste trabalho foi analisar a interação de dois tipos de ativação de sistemas adesivos (fotoativável e ativação dual) e dois tipos de ativação de cimentos resinosos (ativação química e ativação dual) nos valores de microdureza Vickers dos cimentos em diferentes profundidades de polimerização e diferentes proximidades com o sistema adesivo utilizado. Foram utilizados 50 incisivos bovinos inferiores que tiveram suas coroas seccionadas transversalmente para a utilização da porção radicular. Os condutos radiculares foram preparados para a cimentação de pino de fibra de vidro. Os dentes foram divididos aleatoriamente em cinco grupos: I) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce; II) Sistema adesivo Prime & Bond 2.1 e cimento resinoso dual EnForce; III) ED Primer e cimento resinoso químico Panavia 21; IV) Sistema adesivo Clearfil SE Bond e cimento resinoso químico Panavia 21 e V) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce. No grupo V o cimento EnForce não foi fotoativado ficando apenas com a ativação química. Após a cimentação dos pinos as raízes foram então seccionadas em três secções de 3 mm de espessura (cervical, média e apical) e após sete dias foi feita a análise da microdureza Vickers. As secções de cada terço foram divididas em quadrantes iguais e em cada quadrante foram realizadas duas identações, sendo uma próxima ao pino de fibra de vidro e a outra próxima à parede do conduto radicular. Os resultados foram submetidos à análise estatística ANOVA três critérios, havendo diferença estatística entre os grupos foi feito o teste de Tukey para a comparação dos grupos dois a dois. A aplicação do teste de Análise de Variância à três critérios revelou haver diferenças estatisticamente significantes para as variáveis independentes: grupo, posição, região, interação entre grupo e posição (p<0,001), e interação entre grupo e região (p=0,041), não havendo, contudo, diferença estatisticamente significante para as interações entre posição e região (p=0,983) e para a interação entre grupo, posição e região (p=0,85). Concluiu-se que: a dureza superficial, independente do tipo de cimento e dos sistemas adesivos esteve sempre presente em todas as regiões analisadas do canal radicular; o cimento resinoso quimicamente ativado (GIII) apresentou maiores valores de dureza superficial quando comparado ao cimento resinoso de dupla ativação, independente da região analisada do canal radicular; o fator profundidade de polimerização interferiu nos valores de dureza superficial em todos os grupos, sendo mais evidente para os grupos onde o cimento foi fotoativado (GI e GII) do que para os grupos com ativação química (GIII, GIV e GV) que mostraram maior uniformidade nos três terços do conduto radicular; Houve interferência dos sistemas adesivos utilizados nos valores de microdureza para todos os grupos, o que pode ser observado nos menores valores encontrados próximo aos sistemas adesivos, sendo mais evidente no GIV que utilizou o sistema adesivo autocondicionante e menos evidente no grupo III que utilizou o Primer do próprio cimento, mostrando a incompatibilidade entre os sistemas adesivos com menor pH e a fase quimicamente ativada dos cimentos resinosos.
378

Avaliação numérico-experimental da distribuição de tensões geradas pela contração de polimerização de resinas compostas / Numerical-experimental evaluation of the distribution of the stresses produced by polymerization shrinkage of composite resins

Baggio, Rafael 23 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:13Z (GMT). No. of bitstreams: 1 Rafael Baggio.pdf: 2179064 bytes, checksum: 054756974bbbe9db77284217ea63ed04 (MD5) Previous issue date: 2010-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to evaluate the distribution of the stresses generated by the polymerization shrinkage of three composite resins [FiltekTM Z250 (3M ESPE, St. Paul, Minn., USA); FiltekTM Z350 (3M ESPE, St. Paul, Minn., USA) and P-90 (3M ESPE, St. Paul, Minn., USA)], with mechanical tests and finite element analysis (FEM). Ten samples of each composite resin were prepared in metal matrix of 25 X 2 X 2 mm and were tested in the flexural 3 points bend strength in a universal testing machine and a cross-head speed of 0.5 mm / min. After, more 10 samples of each composite resin were prepared in a metal matrix in the form of an hourglass measuring 10 x 3 x 1.5 mm with a central bottleneck of 1.5 mm were submitted to a tensile strength in an universal testing machine with a load cell of 10 N and a crosshead speed of 1.0 mm / min until material failure occurred. After, FEM analysis was made simulating the effects of a class V restoration. In the mechanical tests of tensile strength (MPa) and 3 points bend flexural strength (MPa) respectively, all composites obtained similar results, being to FiltekTM Z-250 (36.51 ± 8.14 and 158.51 ± 31.80), to FiltekTM Z-350 (34.43 ± 6.49 and 146.65 ± 18.83) and to FiltekTM P90 (37.35 ± 7.51 and 148.00 ± 26.24) with no statistical differences by Two-way ANOVA test andBonferroni (alpha = 0.05) post-hoc. In the FEM analysis, the silorane based resin (FiltekTM P90) showed lower values of tension produced by polymerization shrinkage and better able to dissipate it by the adjacent structures. / Este trabalho tem como objetivo avaliar a distribuição de tensões geradas pela contração de polimerização de 3 resinas compostas [FiltekTM Z-250 (3M ESPE, St. Paul, Minn., USA); FiltekTM Z-350 (3M ESPE, St. Paul, Minn., USA) e P90 (3M ESPE, St. Paul, Minn., USA)], através de testes mecânicos e análise por meio do método de elementos finitos. Inicialmente, 10 cp de cada resina composta foram confeccionados em matrizes metálicas de 25 X 2 X 2 mm e submetidos ao ensaio de resistência flexural de 3 pontos em uma Máquina de Ensaios Universal à uma velocidade de 0,5 mm/min. Para o teste de resistência à tração, foram confeccionados 10 cp para cada grupo de resina composta, mas agora em uma matriz metálica em forma de ampulheta medindo 10 x 3 x 1,5 mm com um estrangulamento central de 1,5 mm. Em seguida, as amostras foram submetidas ao teste de resistência à tração em uma Máquina de Ensaios Universal com uma célula de carga de 10 N a uma velocidade de 1,0 mm/min até que ocorreu a fratura no material. Com os dados obtidos em laboratório, uma simulação computacional foi realizada através do MEF, simulando os efeitos de uma restauração classe V na região cervical da face vestibular de um pré-molar. Nos testes mecânicos, após análise de variância ANOVA dois critério e pós-teste de Bonferroni com alfa igual a 0,05, não foram encontradas diferenças estatísticas para a resistência à tração (MPa) e resistência flexural (MPa) respectivamente entre as resinas FiltekTM Z-250 (36,51 ± 8,14 e 158,51 ± 31,80), FiltekTM Z-350 (34,43 ± 6,49 e 146,65 ± 18,83) e FiltekTM P90 (37,35 ± 7,51 e 148,00 ± 26,24). Na análise pelo método de elementos finitos, a resina à base de silorano (FiltekTM P90) obteve menores valores de tensões produzidas pela contração de polimerização e conseguiu uma melhor dissipação da mesma pelas estruturas adjacentes.
379

Avaliação da resistência ao cisalhamento de braquetes colados com resinas ortodônticas fluoretadas

Rastelli, Márcia Cristina 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:14Z (GMT). No. of bitstreams: 1 MarciaCristinaR.pdf: 1130793 bytes, checksum: 7d9d617dfc4b2b8f59066d8b013a6268 (MD5) Previous issue date: 2006-02-22 / The aim of this study was to evaluate the shear bond strength of brackets bonded with fluoride-releasing composite resins, and to compare them to a conventional resin. For this study, sixty premolars extracted due to orthodontic reasons were used, which were divided into three groups: Group 1- Concise (3M), Group 2- Ultrabond (Aditek do Brasil) and Group 3- Rely-a-bond (Reliance). All bonded specimens were stored in distilled water at 37°C for 24 hours and termocycled between 5°C and 55°C for 500 cycles. After 48 hours, the specimens were submitted to the shear bond strength test, in occluso-gingival direction, in Material Test System MTS 810 machine, with load speed of 0.5 mm/min. Variance Analysis, Levene Test, Shapiro-Wilk Test and Tukey Test were used for data analysis. The results demonstrated a mean shear bond strength of 24.54 ± 6.98 MPa for the Concise; 11.53 ± 6.20 MPa for the Ultrabond; and of 16.46 ± 5.72 MPa for the Rely-a-Bond. Variance Analysis determined a statistical difference amongst groups (p<0.001). Tukey Test evidenced that the averages of the three groups were significantly different among themselves (p<0.05), with the highest resistance for the Concise Group and the lowest for the Ultrabond Group. However, all the materials presented bond strengths, which were suitable for clinical use. / O objetivo deste estudo foi avaliar a resistência ao cisalhamento de braquetes colados com resinas que contém flúor, e compará-las a uma resina convencional. Para este estudo, foram utilizados 60 pré-molares extraídos por motivo ortodôntico, os quais foram divididos em 3 grupos, sendo 20 corpos-de-prova para cada um: Grupo I - Concise (3M), Grupo II – Ultrabond (Aditek do Brasil) e Grupo III - Rely-a-Bond (Reliance). Todos os corpos-de-prova foram armazenados em água destilada a 37°C, por 24 horas e termociclados com 500 ciclos, nas temperaturas de 5°C e 55°C. Após 48 horas, os corpos-de-prova foram submetidos aos ensaios mecânicos de cisalhamento na direção ocluso-cervical, na máquina Material Test System MTS 810, com velocidade de carga de 0,5 mm/min. Para a análise dos dados, utilizou-se a Análise de Variância, Teste de Levene, Teste de Shapiro-Wilk e o Teste de Tukey. Os resultados demonstraram uma resistência média ao cisalhamento de 24,54 ± 6,98 MPa para o Grupo I (Concise), de 11,53 ± 6,20 MPa para o Grupo II (Ultrabond) e de 16,46 ± 5,72 MPa para o Grupo III (Rely-a-Bond). A Análise de Variância determinou diferença estatística entre as médias de resistência ao cisalhamento entre os grupos (p<0,001). O teste de Tukey evidenciou que as médias dos três grupos foram significativamente diferentes entre si (p<0,05), com a maior resistência para o Grupo I (Concise) e a menor para o Grupo II (Ultrabond). Entretanto, todos os materiais apresentaram resistência adesiva adequada para uso clínico.
380

Análise in vitro da resistência fluxural de uma resina composta direta e uma resina laboratorial de segunda geração associadas ou não a fibras de reforço

Portero, Priscila Paiva 22 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:15Z (GMT). No. of bitstreams: 1 Priscila Paiva.pdf: 771030 bytes, checksum: 5f6283269831858bcc9efe855624762e (MD5) Previous issue date: 2006-02-22 / The present study aims to evaluate in vitro the flexural strength of the direct composite resin (FiltekTM Z-250 – 3M/ESPE) and of the second generation laboratory resin (CeseaDST II – Kuraray) either associated or not to glass fibers (Fibrex-coronal – Angelus), varying the source of photoactivating (L.E.Demetron 1 – Kerr e Strobolux – EDG). Fifty-six samples were made inside a biparted metalic matrix, 13.0 mm in diameter X 2.4 mm thick, divided into 8 study groups (n=7): GI – Resin FiltekTM Z-250/ Fibreless/ LED; GII – Resin FiltekTM Z-250/ Fibreless/ Strobolux; GIII - Resin FiltekTM Z-250/ Fibrex-coronal/ LED; GIV - Resin FiltekTM Z-250/ Fibrex-coronal/ Strobolux; GV – Resin CeseaDST II/ Fibreless / LED; GVI - Resin CeseaDST II/ Fibreless / Strobolux; GVII - Resin CeseaDST II/ Fibrexcoronal/ LED; GVIII - Resin CeseaDST II/ Fibrex-coronal/ Strobolux. The samples were under the test of biaxial flexural strength in the Kratos equipment, with speed of 1 ± 0.5 mm/min and load cell of 500 Kgf. The flexural strength values were submitted to the Tukey test (P=0,01). The rate of the results in MPa were: GI – 187.91 ± 32.78; GII – 196.76 ± 31.15; GIII – 208.27 ± 18.79; GIV – 218.02 ± 15.76; GV – 101.72 ± 11.25; GVI – 103.05 ± 9.56; GVII – 164.76 ± 12.54 e GVIII – 176.75 ± 47.03. The conclusion is that the analyzed composites showed different behaviors in vitro; the direct composite FiltekTM Z-250 showed higher values of flexural strength in all the studied groups; the type of light source did not interfere in the flexural strength of the evaluated composites; reinforcement with fibers increased the flexural strength both evaluated composites, however only for the indirect composite CeseaDST II that increase was significant. / O objetivo deste estudo foi avaliar in vitro a resistência flexural da resina composta direta (FiltekTM Z-250 – 3M/ESPE) e da resina laboratorial de segunda geração (CeseaDST II – Kuraray) associadas ou não a fibras de vidro (Fibrexcoronal – Angelus), variando a fonte de luz fotoativadora (L.E.Demetron 1 – Kerr e Strobolux – EDG). Foram confeccionados 56 corpos-de-prova (CP) em uma matriz metálica bipartida com as dimensões de 13,0 mm de diâmetro X 2,4 mm de espessura divididos em 8 grupos (n=7) de estudo: GI - Resina FiltekTM Z-250/ Sem fibras/ LED; GII – Resina FiltekTM Z-250/ Sem fibras/ Strobolux; GIII - Resina FiltekTM Z-250/ Fibrex-coronal/ LED; GIV - Resina FiltekTM Z-250/ Fibrex-coronal/ Strobolux; GV – Resina CeseaDST II/ Sem fibras/ LED; GVI - Resina CeseaDST II/ Sem fibras/ Strobolux; GVII - Resina CeseaDST II/ Fibrex-coronal/ LED; GVIII - Resina CeseaDST II/ Fibrex-coronal/ Strobolux. Os CP foram submetidos ao teste de resistência flexural biaxial no equipamento Kratos com velocidade de 1 ± 0,5 mm/min e célula de carga de 500 Kgf. Os valores de resistência flexural foram submetidos ao teste de Tukey (P=0,01). A média dos resultados em MPa foram: GI – 187,91 ± 32,78; GII – 196,76 ± 31,15; GIII – 208,27 ± 18,79; GIV – 218,02 ± 15,76; GV – 101,72 ± 11,25; GVI – 103,05 ± 9,56; GVII – 164,76 ± 12,54 e GVIII – 176,75 ± 47,03. Concluiu-se que: os compósitos avaliados apresentaram diferentes comportamentos in vitro; o compósito direto FiltekTM Z-250 apresentou maiores valores de resistência flexural em todos os grupos estudados; o tipo de fonte de luz não interferiu na resistência flexural dos compósitos avaliados; o reforço com fibras aumentou a resistência flexural de ambos os compósitos avaliados, sendo que apenas para o compósito indireto CeseaDST II esse aumento foi significante.

Page generated in 0.075 seconds