• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 789
  • 220
  • 83
  • 54
  • 35
  • 15
  • 14
  • 11
  • 11
  • 11
  • 6
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 1395
  • 496
  • 385
  • 205
  • 184
  • 162
  • 162
  • 154
  • 147
  • 143
  • 135
  • 113
  • 110
  • 103
  • 102
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Efeito de inibidores da atividade proteolítica na resistência de união de pino de fibra de vidro à dentina radicular após 12 meses / Effect of proteolytic activity inhibitors on bond strength of glass-fiber post to radicular dentin up to 12 months

Chaves, Larissa Pinceli 19 August 2016 (has links)
O estabelecimento de uma camada híbrida adequada no canal radicular representa um dos principais desafios clínicos devido à dificuldade de acesso. Dessa forma, o uso de inibidores proteolíticos poderia tornar-se um recurso favorável. O objetivo deste estudo foi avaliar o efeito de inibidores proteolíticos na união de pino de fibra de vidro fixado com cimento adesivo, considerando os terços radiculares e tempos distintos, por meio da resistência de união (RU). Cento e quarenta e quatro raízes bovinas foram selecionadas e divididas em 6 grupos de tratamento, e redivididas em 3 subgrupos de acordo com os tempos de avaliação de 24 horas, 6 e 12 meses (n=8). Após o tratamento endodôntico e desobturação padronizados, as raízes foram cimentadas com pinos de fibra de vidro cônicos (Exacto/Angelus). As raízes foram tratadas com sistema adesivo convencional de três passos, Adper Scotchbond Multipurpose/ 3M ESPE (SBMP) e cimento dual RelyX ARC/ 3M ESPE. Após prévia divisão, foram alocadas em grupos CN (Controle Negativo- sem pré tratamento associado), CP (Controle Positivo- com agentes ativador e catalisador), EDTA (ácido etilenodiamino tetra-acético a 17%), CHX (digluconato de clorexidina a 2%), E-5 (E- 64 a 5 M) e E-10 (E-64 a 10 M). Após 24 horas, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias de 1 mm de espessura (cervical, médio e apical), que foram armazenadas em saliva artificial para serem testadas. Todas as fatias foram submetidas ao teste de extrusão (push-out) na máquina de teste universal (Instron) com célula de carga de 50 N a 0,5 mm/min. Os dados foram analisados pelo teste de ANOVA a três critérios e comparações múltiplas com Tukey, ambos com p<0,05. Após 24 horas, não se observou diferenças entre os tratamentos. Após 6 meses, a CHX demonstrou melhor desempenho, cujo efeito não se prorrogou até os 12 meses. O uso de inibidores proteolíticos não foram capazes de preservar a resistência de união dos pinos intrarradiculares até o tempo de 12 meses. / The adequate establishment of hybrid layer in the root canal on bonding process is still a clinical challenge due to its hard access. Thus, the use of proteolytic inhibitors could become a favorable tool. The aim of this study was to evaluate the effect of proteolytic inhibitors in the bonding of a glass- fiber post fixed with a luting cement, regarding the root thirds and different times through the bond strength. One hundred and forty four bovine roots were selected and divided into 6 treatment groups, and subdivided according to the time of evaluation of 24 hours, 6 and 12 months (n=8). After endodontic treatment and standardized removal procedure, the roots were cemented with tapered glass fiber posts (Exacto/ Angelus). The roots were treated with three-step etch-and-rinse adhesive system Adper Scotchbond Multipurpose/ 3M ESPE (SBMP) and dual cement RelyX ARC/ 3M ESPE. After previous division, CN (negative- control without pre associated treatment), CP (Control positive- with activator and catalyst agents) EDTA (17% ethylenediaminetetraacetic acid) CHX (2% chlorhexidine digluconate) E-5 (5M E-64) and E-10 (10M E-64). After 24h, the roots were sectioned perpendicular to the long axis and identified according to third in 1mm thick slices (cervical, middle and apical), which were stored in artificial saliva to be tested. All slices were subjected to extrusion tests (push-out) in the universal test machine (Instron) at 50 N load cell at 0.5 mm/min. Data were analyzed with three-way ANOVA and multiple comparisons with Tukey test, both with p <0.05. After 24 hours, no differences were observed between treatments. After 6 months, CHX showed better performance, which did not last up 12 months. The proteolytic inhibitors performed differently in the bonding process over time; only CHX promoted inhibition at 6 months. The use of proteolytic inhibitors were not able to maintain the bond strength of intraradicular posts up time of 12 months.
362

Estabilidade dimensional da resina acrílica para coroas provisórias em função de diferentes tipos de processamento / Dimensional stability of acrylic resin for provisional crowns for different types of processing

García-López, David Alejandro 27 April 2009 (has links)
A importância das restaurações provisórias no tratamento reabilitador oral é inquestionável. Os materiais utilizados para a elaboração deste tipo de restauração, também são de grande importância, tanto em função da técnica de manuseio como na qualidade e características dos mesmos, devido ao fato de que deles depende a longevidade, adaptação e qualidade das restaurações provisórias. O tipo de manipulação e a técnica utilizada influem nas propriedades físicas das resinas acrílicas, o que poderia causar falhas de adaptação. Por essas razões, o presente estudo teve por objetivo avaliar a estabilidade dimensional de uma resina acrílica (Dencor®), utilizada na confecção de coroas provisórias. Foram avaliados cinco tipos de processamento: I polimerização térmica utilizando líquido de polimerização rápida em mufla; II autopolimerização sob pressão em matriz de aço inox; III autopolimerização utilizando pincel; IV autopolimerização após mistura (pó + líquido) em pote dappen e inserção em matriz de aço inox na fase arenosa; V autopolimerização após mistura em pote dappen com inserção na matriz de aço inox na fase plástica. Para cada tipo de processamento foram confeccionados 10 corpos-de-prova. Foi avaliada sua estabilidade dimensional por meio de matrizes de aço inox confeccionadas seguindo a especificação da ADA No 19. Os corpos de prova foram armazenados em água destilada a uma temperatura de 37oC por 6 meses. Durante este tempo eles foram examinados com o microscópio óptico Mitutoyo com aumento de 20 vezes. Os resultados foram submetidos à análise de variância (Teste de Tukey) em nível de 5% de significância. Dos resultados obtidos, observamos que todos os corpos de prova tiveram as alterações dimensionais nos primeiros 7 dias da pesquisa independente da técnica utilizada. Já nos dias 30, 90, 180 não foi observada nenhuma alteração dimensional estatisticamente significante. / The importance of the provisional restorations in the oral rehabilitation treatment is undebated. The materials used for the fabrication of this type of restoration, are, as well, of great importance, as much as in function of the processing technique as in their quality and characteristics, due the fact that of them depend the longevity, adaptation and quality of the restorations. The mixing and processing technique influence the physical properties of acrylic resins, what could interfere with the adaptation of the provisional crowns. For these reasons, the present study aimed at evaluating the dimensional stability of an acrylic resin (Dencor®), used for fabrication of provisional crowns. Five types of processing techniques were evaluated: I thermal polymerization using fast polymerization liquid and flask; II - autopolimerization under pressure in stainless steel matrix; III - autopolimerization using bead brush technique to build the sample; IV - autopolimerization after mixture (powder + liquid) in dappen dish and insertion in stainless steel matrix at the sand phase; V - autopolimerization after mixture in dappen dish with insertion in the stainless steel matrix at the plastic phase. For each type of processing technique, 10 samples were made. Dimensional stability was evaluated by means of steel matrices made following the ADA specification no 19. The samples were stored in distilled water at a temperature of 37oC for 6 months. During this time they were examined with the optic microscope Mitutoyo with 20x magnification. The results were subjected to the analysis of variance (Test of Tukey) at the significance level of 5%. From the results obtained, it could be observed that all samples had dimensional alterations in the first 7 days independent of the technique used. In days 30, 90, 180 there were no statisticaly significant dimensional alteration.
363

Avaliação clínica longitudinal de dois selantes de fossas e fissuras à base de resina

Kobayashi, Tatiana Yuriko 24 April 2009 (has links)
Os objetivos deste trabalho foram avaliar e comparar por 24 meses, a retencao e as caracteristicas superficiais de dois diferentes materiais seladores, Helioseal Clear e Helioseal F ambos da Ivoclar Vivadente, AG - Schaan, Liechtenstein. Participaram desse estudo, 50 criancas de 6 a 8 anos de idade, com no minimo dois primeiros molares permanentes higidos e historia de carie, num total de 153 dentes divididos em dois grupos: GHC(Helioseal Clear) e GHF (Helioseal F). O selamento foi realizado sob isolamento relativo para todos os grupos, após profilaxia previa com jato de bicarbonato (Profident Dabi-Atlante) e agua e, condicionamento com gel de acido fosforico a 34% por 15 segundos. Apos 6, 12, 18 e 24 meses, a avaliacao clinica foi realizada por dois examinadores calibrados. Avaliou-se a retencao e a incidencia de carie nas 5 areas oclusais: OM, OC, OD, OV e OL (DEERY et al.) e; as caracterisiticas superficiais e a retencao considerando a superficie oclusal com o um todo (criterio modificado de RYGE &SNYDER).Nao houve diferenca estatisticamente significante atraves do teste exato de Fisher na taxa de sucesso (p=0,496 a 1,0) ou para a incidencia de carie (p=0,472 a 1,0) entre as areas avaliadas quando comparado o GHC com GHF durante todo o período estudado. Considerando todas as areas juntas e os grupos separados ou, os dois grupos juntos mas as areas separadas, nao houve diferenca estatisticamente significante, respectivamente, pelo teste de Fisher (p=0,170 a 0,534) e do Qui- Quadrado (p=0,058 a p=0,909), quanto ao sucesso na retencao em nenhum periodo. Quanto a analise da superficie oclusal toda quanto a retencao, esta foi maior e estatisticamente significante para o GHC aos 12m (p=0,0345) e 24m (0,0076). Em relacao as caracteristicas superficiais, o GHC so nao apresentou superioridade quanto a descoloracao superficial, durante o periodo estudado. Para as demais caracteristicas, os resultados do teste de Mann-Whitney foram altamente significantes em diferentes periodos (p= 00000 a 0,0421). A frequencia de bolhas nas superficies seladas, determinada pelo teste do Qui-quadrado, foi maior e significante (p=0,000:12 e 18 meses a p=0,002: 6 e 24 meses) no GHF. Portanto, pode-se concluir que quanto a retencao e caracteristicas superficiais, na superfície oclusal toda, o selante Helioseal Clear apresentou melhor desempenho. / The objectives of this study were evaluated and compared for 24 months, the retention and surface characteristic of two different sealing materials, and Helioseal F Clear Helioseal both of Ivoclar Vivadent, AG - Schaan, Liechtenstein. 50 children from 6 to 8 years of age with at least with two sound first permanent molars and caries of history, total of 153 teeth, were divided into 2 groups: GHC (Helioseal Clear) and GHF (Helioseal F). The sealing was done with ruber dam for all groups, after prophylaxis with air-polishing jet (Profident --Dabi Atlante) and water, and acidetching with 34 % phosphoric acid 34% for 15 seconds. After 6, 12, 18 and 24 months, clinical evaluation was evaluated by two calibrated examiners. To evaluate the retention and the incidence of occlusal caries in 5 areas: OM, OC, OD, and OV OL (DEERY et al.). And, the surface characteristics and retention considering the all occlusal surface (modified criterion RYGE & SNYDER ). There was no statistically significant by Fisher\'s exact test in the rate of success (p = 0,496 to 1.0) or the incidence of caries (p = 0,472 to 1.0) between the areas assessed when compared with the GHC GHF throughout the study period. Considering all areas and groups together or separated, the two groups together but separate areas, there was no statistically significant difference, respectively, by Fisher\'s test (p = 0170 to 0534) and Chi-Square (p = 0,058 to 0,909), about the success in holding in any period. The analysis of the entire occlusal surface on retention, it was higher and statistically significant for the GHC to 12m (p = 0.0345) and 24m (0.0076). In relation to surface characteristics, the GHC showed superiority not only on the superficial discoloration over the period studied. For other characteristics, the results of the Mann-Whitney test were highly significant in different periods (p = 00000 to 0.0421). The frequency of bubbles in the sealed surfaces, as determined by Chi-Square was higher e statistically significant difference (p = 0,000:12 and 18 months p = 0,002: 6 and 24 months) in GHF. Therefore,the retention and surface characteristic in the all occlusal surface, the Helioseal Clear sealant showed better performance
364

Preparação, caracterização e aplicação de eletrodos compósitos à base de nanotubos de carbono e polímeros / Preparation, characterization and aplication of composite electrodes based on carbon nanotubes and polymers

Santos, Sidney Xavier dos 16 May 2011 (has links)
Foram desenvolvidos eletrodos compósitos à base de nanotubos de carbono aglutinados por borracha de silicone e resina poliuretana de origem vegetal, visando aliar as interessantes propriedades dessa forma de carbono como material de eletrodo às vantagens da utilização de eletrodos sólidos. Para isso, os nanotubos adquiridos foram submetidos a um tratamento térmico/químico para eliminar eventuais resíduos metálicos de catalisador e carbono amorfo, bem como ativar sua superfície pela adição de grupos funcionais, abertura das extremidades e criação de defeitos em suas paredes. Os nanotubos foram caracterizados, antes e após o tratamento, utilizando técnicas como espectroscopia no infravermelho, espectroscopia Raman, microscopia eletrônica de varredura, termogravimetria e difração de raios X. Os resultados permitiram concluir que os materiais já vêm pré tratados pelo fabricante e o tratamento adicional leva a uma melhora em suas propriedades eletroquímicas. Posteriormente, os eletrodos compósitos foram preparados com nanotubos de carbono, tratados e na forma como foram recebidos, utilizando borracha de silicone ou poliuretana como aglutinantes. O efeito do tratamento na resposta voltamétrica dos eletrodos compósitos foi avaliado utilizando-se voltametria cíclica. Um estudo da composição do material condutor, composto de misturas de nanotubos de carbono tratados e grafite, indicou que a melhora na resposta do eletrodo é proporcional à quantidade de nanotubos presentes no compósito, verificada pelo aumento na corrente de pico e pela diminuição da separação dos potenciais de pico. Esta melhora foi mais significativa no eletrodo compósito à base de nanotubos de carbono e borracha de silicone, o qual foi aplicado na determinação de propranolol e hidroclorotiazida, dois fármacos utilizados no tratamento de hipertensão. Os procedimentos de determinação foram desenvolvidos e as técnicas de voltametria de pulso diferencial e voltametria de onda quadrada foram utilizadas na quantificação dos fármacos em formulações farmacêuticas, com limites de detecção da ordem de 10-8 mol L-1 para propranolol e 10-6 para hidroclorotiazida. Os resultados foram concordantes com os métodos oficiais descritos nas farmacopéias com 95 % de confiança, de acordo com teste t-Student. Melhor resposta voltamétrica foi propiciada pela presença dos nanotubos, pois não houve a necessidade de pré-concentração para obter resposta quantitativa semelhante às previamente descritas na literatura. / Composite electrodes were developed based on carbon nanotubes bonded by silicone rubber and polyurethane vegetable resin, aiming to combine the interesting properties of this form of carbon as electrode material to the advantage by using solid electrodes. For this, the nanotubes obtained were subjected to a heat/chemical treatment to remove any residual metal catalyst and amorphous carbon, and activate their surface by the addition of functional groups, opening the ends and defects\' creation in their walls. The nanotubes were characterized before and after treatment, using techniques, such as infrared spectroscopy, Raman spectroscopy, scanning electron microscopy, thermogravimetry and X-ray diffraction. The results showed that the material is pre treated by the manufacturer and additional treatment leads to an improvement in their electrochemical properties. Thereafter, the composite electrodes were prepared with treated and as received carbon nanotubes, using silicone rubber or polyurethane as binders. The treatment effect on the voltammetric response of the composite electrodes was evaluated using cyclic voltammetry. A study of the conductive material composition, composed by treated carbon nanotubes and graphite mixtures, indicated that the improvement in sensor response is proportional to the amount of nanotubes present in the composite, as verified by the increase in peak current and the decrease of the separation in the peak potentials. This improvement was more significant in the composite electrode based on carbon nanotubes and silicone rubber which was applied in the determination of propranolol and hydrochlorothiazide, both drugs used for hypertension treatment. The determination procedures were developed and the techniques of differential pulse voltammetry and square wave voltammetry were used for drugs\' quantification in pharmaceutical formulations, with detection limits of 10-8 mol L-1 for propranolol and 10-6 mol L-1 for hydrochlorothiazide. The results were consistent with the described methods in the official pharmacopoeias with 95% confidence, according to Student\'s t-Test. The best voltammetric response was obtained by the presence of the nanotubes, since there was no need for pre-concentration to get similar quantitative response to those previously described in literature.
365

Dispositivo de amostragem passiva com papel e resina para monitoramento de metais potencialmente tóxicos em solo / Passive sampling device with paper and resin for monitoring potentially toxic metals in soil

Grandino, Débora Regina 07 December 2017 (has links)
A identificação de elementos potencialmente tóxicos em solos, a distribuição destes e sua disponibilidade química são importantes para a avaliação de risco ambiental, diagnóstico esse imprescindível para um desenvolvimento sustentável com segurança dos alimentos, da água, da energia, da estabilidade climática, da manutenção da biodiversidade e do ecossistema. Usualmente, a identificação de áreas contaminadas exige a coleta e análise de um número elevado de amostras de solo, que consequentemente elevam os custos e demandam muitas horas de trabalho. Neste sentido, estratégias que permitem determinações mais rápidas a baixo custo e eficientes são desejáveis. Estratégias de amostragem passiva têm sido desenvolvidas para superar as limitações da análise química convencional, além de possuir vantagens adicionais que permitem incorporar a esse diagnóstico as influências edáficas do local amostrado. Outra forma de reduzir custo e aumentar a frequência analítica é o uso de técnicas de análise direta de sólidos, que eliminam ou minimizam o preparo da amostra, e consequentemente o tempo de análise. Visando contribuir no desenvolvimento da amostragem em campo e técnicas de análise direta em sólidos, este trabalho teve por objetivo desenvolver, avaliar e validar um dispositivo de amostragem passiva composto por papel e resina além de comparar aspectos técnicos entre procedimentos convencionais e as técnicas analíticas de análise direta de sólidos: Fluorescência de Raios X (XRF) e Espectrometria de Emissão Óptica Induzida por Laser (LIBS). Para avaliar o conceito foi realizado mapeamento do solo de uma área experimental supostamente contaminada, analisando o conjunto de dados com o auxílio de ferramentas matemáticas de interpolação baseadas na técnica de Krigagem. Testes foram realizados com o intuito de se determinar a melhor forma de acoplamento, condicionamento, processo de adsorção e extração dos elementos de ambas as partes do dispositivo (papel e resina). As duas técnicas de análise direta de sólidos também foram testadas. A XRF trouxe informações com base na distribuição dos elementos, depois de adsorvidos, no papel e na resina, porém não apresentou viabilidade e capacidade (por ter alto background) na quantificação dos elementos. O LIBS mostrou-se promissor para quantificação dos elementos, proporcionando boa correlação com as concentrações presentes no solo, na resina mais (por esta adsorver mais uniformemente os elementos) que no papel e por ser rápido, além de multielementar. Quando inserido em solo contaminado (com altas concentrações dos metais), o dispositivo apresentou ótimas correlações com a quantidade adicionada e com as intensidades fornecidas pelo LIBS. Porém, quando há baixas concentrações não houve uma relação definida entre os diferentes tipos de extração. Acredita-se que o dispositivo tenha potencial para quantificação de elementos potencialmente tóxicos em solos contaminados, por ter respondido bem a extração e determinação neste tipo de solo / Identification of potentially toxic elements in soils, their distribution and their chemical availability are important for environmental risk assessment, an essential diagnostic for sustainable development with security food, water, energy, climate stability, biodiversity and the ecosystem. Usually, the identification of contaminated areas requires the collection and analysis of a large number of soil samples, which consequently raise costs and require many hours of work. In this sense, strategies that allow faster, cost-effective and efficient determinations are desirable. Passive sampling strategies have been developed to overcome the limitations of conventional chemical analysis, besides possessing additional advantages that allow incorporating to this diagnosis the edaphic influences of the sampled site. Another way of reducing cost and increasing analytical frequency is the use of direct solids analysis techniques, which eliminate or minimize the sample preparation, and consequently the analysis time. Aiming to contribute to the development of field sampling and direct solid analysis techniques, the objective of this work was to develop, evaluate and validate a passive sampling device composed of paper and resin and to compare technical aspects between conventional procedures and analytical analysis techniques direct solids: X-ray Fluorescence (XRF) and Laser Induced Optical Emission Spectrometry (LIBS). In order to evaluate the concept, a soil mapping of a supposedly contaminated experimental area was carried out, analyzing the data set with the aid of mathematical interpolation tools based on the Kriging technique. Tests were performed with the purpose of determining the best way of coupling, conditioning, adsorption and extraction of the elements of both parts of the device (paper and resin). The two techniques of direct solids analysis were also tested. The XRF provided information based on the distribution of the adsorbed elements on paper and resin, but it did not present viability and capacity (because of the high background) in the quantification of the elements. The LIBS showed promise for the quantification of the elements, providing a good correlation with the concentrations present in the soil, in the resin more (by this more uniformly adsorb the elements) than in the paper and because it is fast, besides multielementar. When inserted into contaminated soil (with high concentrations of metals), the device showed excellent correlations with the amount added and the intensities provided by the LIBS. However, when there are low concentrations there was no definite relation between the different types of extraction. It is believed that the device has potential for quantification of potentially toxic elements in contaminated soils, since it has responded well to extraction and determination in this type of soil
366

Influência na resistência de união de pinos de fibra de vidro com e sem retenções mecânicas em função dos materiais utilizados para cimentação: teste de \'push-out\' / Influence on the bond strength of glass fiber posts with and without mechanical retentions depending of materials used for cementing: push-out test

Consolmagno-Callejon, Elaine Cristina 08 June 2016 (has links)
Este estudo teve como objetivo avaliar a influência na resistência de união de pinos de fibra de vidro (PFV) com retenções mecânicas (CRM) e sem retenções (SR), associados a três materiais: RelyX ARC cimento resinoso convencional dual com sistema adesivo Adper Single Bond (ASB), convencional de 2 passos; RelyX U200 cimento resinoso auto condicionante dual e resina flow SDR foto ativada, com sistema adesivo Prime & Bond 2.1 (PB), convencional de 2 passos; nos terços cervical (C), médio (M) e apical (A), por meio do teste de push-out. Sessenta incisivos bovinos foram selecionados, tiveram as coroas seccionadas para padronizar 17mm de raiz e foram submetidas ao tratamento endodôntico, para posterior cimentação do PFV. Foram divididas aleatoriamente em 2 grupos (N=30), quanto ao tipo de PFV: CRM - com retenções mecânicas (Glassix+plus no2) e SR - sem retenções (Exacto no2). Todos os PFV apresentavam formato cônico. Cada grupo foi subdividido em 3 (N=10), quanto ao tipo de material: cimento RelyX ARC+ASB; cimento RelyX U200 (auto condicionante) e resina SDR+PB. Todas as orientações dos fabricantes para tempo de manipulação e foto ativação do material foram rigorosamente respeitadas. As raízes foram mantidas em saliva artificial e decorridas 24h da cimentação dos PFV, foram seccionadas perpendicularmente ao longo eixo, obtendo 9 fatias de aproximadamente 1mm, cuja identificação foi feita de acordo com o terço correspondente. O teste de push-out foi realizado em máquina de ensaio universal com célula de carga de 50N; velocidade de 0,5mm/min, da direção apical para a cervical da fatia até que o pino fosse deslocado, respeitando o formato cônico do canal radicular. Todos os espécimes foram analisados em microscopia óptica, aumento de 200 vezes, quanto aos tipos de falha ocorrido. Os dados foram tabulados considerando as variáveis dos diferentes materiais utilizados para a cimentação, presença ou não de retenções mecânicas nos PFV e terços radiculares. Os valores de resistência de união (Ru) obtidos foram submetidos ao teste de normalidade Kolmogorov- Smirnov, à análise de variância a três critérios (ANOVA) e ao teste LSD de Fisher (p<0,05). Os resultados mostraram diferença estatisticamente significante nos terços C, M e A, respectivamente para os cimentos ARC com pino Glassix+plus, média e desvio padrão (MPa) a seguir, 8,50 (4,76); 6,99 (3,55); 4,71 (2,13) e U200 com pino Exacto: 9,40 (4,93); 8,02 (4,67); 4,67 (1,86); a resina SDR não interagiu significativamente com os PFV CRM 6,78 (2,72); 5,97 (2,45); 2,67 (1,55) e SR 7,24 (3,55); 6,86 (2,84); 4,10 (1,90). A análise microscópica mostrou predominância de falhas adesivas entre cimento e dentina e mista para todos os grupos. O cimento U200 com pino Exacto apresentou o melhor desempenho, seguido do ARC com pino Glassix+plus. A resina SDR teve desempenho semelhante para ambos os PFV. Todos os grupos apresentaram valores de Ru maiores no terço cervical, intermediários no terço médio e menores no terço apical. / This study aimed to evaluate the influence on the bond strength of glass fiber posts (GFP) with mechanical retention (WMR) and without retentions (NR), associated with three materials: RelyX ARC total-etching resin cement dual cure with Adper Single Bond (ASB) adhesive system, conventional 2 steps; RelyX U200 self-etching resin cement dual cure, and flowable resin SDR, activated by light, with Prime & Bond 2.1 adhesive system conventional 2 steps in the cervical (C), medium (M) and apical (A) thirds by the \"push-out\" test. Were selected sixty bovine incisors, had the crowns sectioned to root was standardized 17mm, were submitted to endodontic treatment, for cementing the GFP later. Were randomly divided into 2 groups (N=30), according to the GFP: WMR - with mechanical retentions (Glassix+plus &#x2260;2) and NR - without retentions (Exacto &#x2260;2). All GFP had conic shape. Each group was divided into 3 (N=10), according to material: RelyX ARC+ASB, RelyX U200 (self-etching) and flowable resin SDR+PB. All guidelines of manufacturers to handling time and cure time of the material were strictly adhered. The roots were kept in artificial saliva and 24 hours after GFP cementing it were sectioned perpendicular to the long axis, obtaining nine slices of approximately 1mm, which identification was done according to the corresponding third. The \"push-out\" test was performed with a universal test machine, 50N load cell; crosshead speed of 0.5 mm/min, the load was applied in an apical to cervical direction until the post dislodged from the specimen, respecting the conical shape of the root canal. Subsequently, all specimens were analyzed with optical microscopy 200 times increase to evaluate failure modes. Data were tabulated considering the materials used for cementing, presence or absence of mechanical retentions in GFP and root thirds. The bond strength values (BS) were submitted to Kolmogorov-Smirnov normality test, three-way ANOVA and Fisher\'s LSD test (p<0.05). The values showed statistically significant differences in thirds C, M and A, respectively for the ARC with Glassix+plus, average and standard deviation (MPa): 8.50 (4.76); 6.99 (3.55); 4.71 (2.13) and U200 with Exact post: 9.40 (4.93); 8.02 (4.67); 4.67 (1.86). SDR resin does not significantly interacted with GFP WMR 6.78 (2.72); 5.97 (2.45); 2.67 (1.55) and NR 7.24 (3.55); 6.86 (2.84); 4.10 (1.90). The microscopic analysis showed predominance of failure between cement and dentine and mixed for all groups. U200 cement with Exacto post had the best performance, followed by ARC with Glassix+plus post, SDR resin has similar performance for both GFP. All groups showed BS values higher in the cervical third, intermediate in the middle third and smaller in the apical third.
367

Influência do pré-aquecimento e de diferentes regimes de fotoativação na adaptação marginal, grau de conversão e propriedades mecânicas de um compósito nanoparticulado / Influence of preheating and different photoactivation modes on marginal adaptation, degree of conversion and mechanical properties of a nanofiller composite

Salgado, Nívea Regina de Godoy Fróes 27 May 2008 (has links)
Proposição: O objetivo deste estudo foi verificar a influência do pré-aquecimento e de regimes de fotoativação (dois contínuos e um em dois passos com baixa irradiância inicial) sobre a adaptação marginal de restaurações, grau de conversão (GC), resistência à flexão (RF) e microdureza Knoop (KHN) de um compósito. Material e Métodos: O nanocompósito Filtek Z350 foi submetido às seguintes condições experimentais: com ou sem pré-aquecimento a 68ºC através do dispositivo Calset; e fotoativado através de um dos três regimes a seguir: 600mW/cm2 por 20s ou 40s (12 ou 24J/cm2 respectivamente) ou 200mW/cm2 por 20s + intervalo de 1 minuto + 500mW/cm2 por 40s (24J/cm2). O teste de adaptação marginal foi realizado através de microscopia eletrônica de varredura, com a mensuração de gaps em réplicas de cavidades Classe V (n=10) em aumento de 200X. A interface adesiva foi dividida em sete segmentos para o cálculo de freqüência de gaps. GC foi obtido através de espectroscopia em FT-Raman nas faces irradiada e oposta de espécimes (n=3) mantidos durante 24h em ambiente escuro a 37°C. RF do compósito foi medida por ensaio de dobramento em três pontos em espécimes (n=10) armazenados em água destilada por 24h. KHN foi mensurada inicialmente (n=6) após 24h de estocagem a seco. Foi realizada armazenagem em etanol 100%, seguida de segunda medida para o cálculo da redução percentual de KHN. Os resultados foram analisados através de análise de variância e teste de Tukey (=0,05) para os testes de GC, RF e KHN e com os testes de Friedman, Wilcoxon e Kruskal-Wallis para a adaptação marginal. Resultados: As paredes axiais das restaurações apresentaram maior freqüência de gaps quando comparadas às laterais. O pré-aquecimento do compósito reduziu a freqüência de gaps. Os regimes de fotoativação demonstraram freqüência de gaps semelhantes entre si. No teste de GC apenas o fator face foi estatisticamente significativo (p<0,05), com maiores valores médios para as faces irradiadas. O regime de ativação em dois passos causou redução (p<0,01) dos valores médios de RF. No teste de KHN após 24h tanto os fatores principais como a interação apresentaram-se estatisticamente significativos (p<0,05 para modo de fotoativação, p<0,001 para pré-aquecimento e p<0,05 para a interação). Os grupos pré-aquecidos demonstraram em geral menores médias de KHN do que aqueles sem aquecimento. Comparando-se os grupos sem pré-aquecimento, não houve diferença em função do modo de fotoativação. Entre os grupos pré-aquecidos, houve diminuição de KHN para 600mW/cm2 por 20s. Na KHN após etanol apenas o fator pré-aquecimento foi significativo (p<0,001), com as menores médias apresentadas pelos grupos pré-aquecidos. A redução percentual da KHN após armazenamento em etanol ocorreu de forma uniforme para todos os grupos. Conclusões: O pré-aquecimento do compósito estudado promoveu melhor vedamento da interface adesiva sem, no entanto, afetar seu grau de conversão e resistência à flexão. O regime de fotoativação com baixa irradiância inicial reduziu a resistência à flexão do compósito, apesar de produzir grau de conversão similar ao de formas contínuas. O pré-aquecimento pode reduzir a microdureza da superfície irradiada de um compósito. / Proposition: The objective of this study was to verify the influence of preheating and photoactivation modes (two continuous and one in two steps with a low initial irradiance) on restoration marginal adaptation, degree of conversion (DC), flexural strength (FS) and Knoop microhardness (KHN) of a composite. Material and Methods: The nanocomposite Filtek Z350 was evaluated under the following experimental conditions: pre-heated up to 68ºC with the use of Calset device or without preheating; and photoactivated through one of the three regimens: 600mW/cm2 for 20s or 40s (12 and 24J/cm2 respectively) and one in two steps (200mW/cm2 for 20s + 1 minute delay + 500mW/cm2 for 40s (24J/cm2). Marginal adaptation test was performed by scanning electron microscopy, measuring gaps in Class V replica (n=10) under 200X magnification. The adhesive interface was segmented in seven parts for gaps frequency calculus. DC was obtained by FT-Raman spectroscopy in irradiated and non-irradiated surfaces (n=3) of samples stored in dark for 24h at 37C . FS was evaluated in a three-bending test in samples (n=10) after 24h storage in distilled water. KHN was measured (n=6) initially after 24h dark and dry storage. After that, samples were stored in 100% ethanol and KHN percentual reduction calculated. Results were analysed by ANOVA and Tukey\'s test (=0.05) DC, FS and KHN and with Friedman, Wilcoxon and Kruskal-Wallis tests for marginal adaptation. Results: Axial walls of the restorations showed higher gaps frequency than lateral walls. Composite preheating leaded to a lower gaps frequency. Photoactivation modes demonstrated similar gap frequency. In DC test only the main factor surface was significant (p<0.05), with higher mean values for irradiated surfaces. The two steps regimen reduced (p<0.01) mean FS values. About KHN after 24h, both main factors and their interaction were significant (p<0.05 for photoactivation mode, p<0.001 for pre-heating use and p<0.05 for interaction). Generally pre-heated groups showed lower KHN means than non-preheated. Comparing non-preheated groups there was not a statistical difference regardless the photoactivation mode. In preheated groups, KHN mean for 600mW/cm2 during 20s was lower than means for other irradiation regimens. In KHN after ethanol, the main factor pre-heating was significant (p<0.001). Preheated groups showed lower means than non-preheated. KHN percentual reduction after ethanol storage occured in a uniform way for all groups. Conclusions: Preheating of the nanocomposite in study promoted a better adhesive interface sealing without compromising the degree of conversion and flexural strength. The photoactivation method that uses a low initial irradiance reduced composite flexural strength in spite of the similar degree of conversion was reached, comparing to continuous modes. Pre-heating can reduce irradiated surface microhardness.
368

Influência da opacidade da infraestrutura do dissilicato de lítio na polimerização do cimento resinoso dual, por teste de microdureza Knoop / Influence of opacity the lithium disilicate infrastructure in dual-cured resin cement by Microhardness knoop

Costa Neto, Dylton Augusto Rodrigues da 25 June 2013 (has links)
As restaurações indiretas em sistemas totalmente cerâmicos desenvolveram-se visando à obtenção de próteses com melhor capacidade de mimetismo do dente natural. Além das propriedades óticas, essas restaurações devem ter adesão ao substrato de suporte, de modo a promover a união entre a cerâmica, o esmalte e a dentina, formando um corpo único, permitindo a transferência de tensões da restauração para a estrutura dental. Alguns fatores como: composição, espessura, opacidade e a cor do material cerâmico podem interferir na passagem de luz e, consequentemente, diminuir o grau de conversão do cimento, limitando o alcance de suas propriedades mecânicas e prejudicando o desempenho clínico. Dessa forma, este trabalho teve por objetivo avaliar a influência de diferentes níveis de opacidade da infraestrutura do dissilicato de lítio na polimerização de um cimento resinoso dual. Foram utilizados quatro discos de cerâmica (IPS e.max Press, IvoclarVivadent, Schaan, Liechtenstein), um para cada opacidade da infraestrutura (HT, LT, MO e HO) recobertas por sua respectiva cerâmica de cobertura (IPS e.max ceram na cor A3), e um grupo de cimento sem a cerâmica interposta (grupo-controle). Para cada grupo foram polimerizados 15 corpos de prova de cimento resinoso (Variolink II, Ivoclar Vivadent, Schaan, Liechtenstein). Foi mensurado o grau de conversão do cimento com o teste de microdureza knoop. Cada corpo de prova foi avaliado imediatamente após a polimerização e após sete dias. Foram feitas cinco endentações para cada tempo e obtida uma média de cada corpo de prova. O grupo com disco de maior opacidade (HO) apresentou o menor valor de microdureza (9,48 ± 0,36) no tempo inicial. O maior valor de microdureza foi o do grupo-controle após 07 dias (38,51 ± 1,05). Os grupos com disco LT e MO apresentaram comportamento igual nos dois tempos, não havendo diferença entre eles. O maior valor de microdureza com o uso de discos cerâmicos foi o do grupo HT após 07dias (29,53 ± 1,81), o qual apresentou valor próximo do controle inicial, porém estatisticamente diferente. Conclui-se que o nível de opacidade da infraestrutura do dissilicato de lítio pode influenciar no grau de polimerização de um cimento resinoso dual. / The indirect restorations in totally ceramic systems have been developed in order to obtain prostheses with improved ability to mimicry of the natural tooth. In addition to optical properties, these restorations must have adhesion to the supporting substrate so as to promote the bonding between the ceramic, enamel and dentin, forming a single body, allowing the transfer of stresses to the structure of the dental restoration. Some factors such as composition, thickness, opacity and color of the ceramic material can interfere with the transmission of light and, consequently, decrease the degree of conversion of the cement, impairing their mechanical properties and impairing clinical performance. Thus, this study aimed to evaluate the influence of different opacity levels of lithium disilicate infrastructure in the polymerization of a dual resin cement. Four ceramic discs were used (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein), one for each opacity infrastructure (HT, LT, MO and HO) covered by their respective veneering ceramic (IPS e.max ceram in color A3) and a group of ceramic cement without an intermediary (control group). For each group there were 15 specimens (n=15) (Variolink II, Ivoclar Vivadent, Schaan, Liechtenstein). The degree of conversion of the cement was measured with the Knoop microhardness test. Each specimen was evaluated immediately after polymerization and after seven days. Five indentations were made for each time and obtained an average of each specimen. The group with the largest disk opacity (ho) had the lowest microhardness value (9.488 ± 0.364) at baseline. The control group showed the highest microhardness the after 07 days (38.517 ± 1.055). Groups with LT and MO disk behaved the same on both days, with no difference between them. The highest microhardness using ceramic disc was in the HT group after 07dias (29.530 ± 1.812). It was concluded that the lithium disilicate infrastructure level of opacity influence the degree of polymerization of a dual resin cement.
369

Processamento de próteses totais: influência de 4 técnicas na alteração daposição dos dentes artificiais. / The processing of complete denture: influence of four techniques in artificial teeth movement.

Barnabé, William 03 April 2000 (has links)
O processamento de resinas acrílicas utilizadas na confecção de bases de prótese envolve alterações dimensionais e distorções da base e movimentação dos dentes artificiais que podem levar à não utilização das próteses por desadaptação, dificuldade de engrenamento dos dentes e estética. Esse estudo avaliou a relação entre a movimentação dos dentes artificiais com os procedimentos de inclusão, prensagem e polimerização das bases de próteses totais. Foram utilizadas 64 amostras, divididas em quatro grupos de 16 (8 inferiores e 8 superiores) que receberam o seguinte tipo de inclusão, prensagem e processamento: a) grupo 1: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, com muralha de silicona, prensagem por uma hora e polimerização em microondas, b) grupo 2: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por 12 horas e polimerização em banho de água, utilizando o ciclo de curta duração, c) grupo 3: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, adaptadas para injetora de acrílico, com muralha de gesso pedra e polimerização em microondas, uma hora após a injeção do molde e d) grupo 4: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por uma hora e polimerização em banho de água, utilizando o ciclo de curta duração. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram contração após o processamento, b) a técnica com menor movimentação dos dentes artificiais foi a técnica 1, que apresentou diferença estatisticamente significativa em relação às demais c) quando comparados os arcos superiores e inferiores, independente da técnica e das medidas avaliadas, não se percebeu diferença estatisticamente significativa d) O tempo de prensagem, após a inclusão e antes da polimerização das próteses, interferiu na movimentação dos dentes artificiais e e) a medida que apresentou maior alteração foi a distância entre os molares, com diferença estatisticamente significativa com as demais. / The processing of acrylic resins used in the construction of complete denture bases involve dimensional alterations, distortion and artificial tooth movement which may prevent the prosthesis from being used due to discomfort, inadequate occlusion and esthetics. This study evaluated the relationship between artificial tooth movement, with the procedures of inclusion, compression and polymerization of complete dentures bases. The sixty-four samples utilized were divided into four groups of 16 (8 lower and 8 upper) which received the following type of inclusion, compression and processing: a) group 1: in this group all samples were included in resin-fiber reinforced flasks, with a silicone mould, compression for one hour and microwave polymerization; b) group 2: in this group all samples were included in metallic flasks, with a silicone mould, compression for 12 hours and thermopolymerization in water bath, using a short duration cycle; c) group 3: in this group all samples were included with gypsum stone mould using an acrylic injector to insert the resin inside the flasks, followed by microwave polymerization, one hour after mould injection and; d) group 4: in this group all samples were included in metallic flasks, with a silicone mould, compression for one hour and thermopolymerization in water bath, using short duration cycle. According to the results the following conclusions were drawn: a) contraction was observed in all samples after processing; b) group 1 presented statistically significant less artificial tooth movement, relative to the others; c) comparing the upper and lower arches, regardless of the technique and measurements evaluated, no statistically significant difference was found; d) the compression time following inclusion and before prostheses polymerization had a negative effect on artificial tooth movement and e) the biggest discrepancies were found in the distance between contralateral molars, with statistically significant difference to other measurements.
370

Ablação a laser de substratos dentais: esmalte,dentina e resinas compostas. / Laser Ablation of dental substrates: enamel, dentin and composite resins.

Lizarelli, Rosane de Fátima Zanirato 14 November 2002 (has links)
O laser de alta intensidade é aceito atualmente como um instrumento satisfatório para remoção seletiva e precisa dos tecidos dentais cariados. Se corretamente usado, os lasers minimizam a perda de tecido sadio além de promoverem conforto aos pacientes. O conhecimento dos aspectos básicos da ablação a laser de tecidos dentais e materiais odontológicos pode conduzir ao desenvolvimento de um protocolo de parâmetros que possam permitir a remoção seletiva de tecidos cariados e resinas insatisfatórias preservando o tecido dental sadio. Os lasers de Nd:YAG, no regime de picossegundos, não estão ainda disponíveis para uso clínico odontológico. Sendo assim, estudos que permitam o máximo de informações relacionadas a esse sistema e ao órgão dental são bem-vindos, para estabelecer normas e parâmetros seguros para sua utilização, num futuro breve, na prática clínica. Três experimentos empregando o laser de Nd:YAG no regime de picossegundos foram executados: o mapeamento térmico, análise micromorfológica e cálculo da taxa de ablação, todos no nível de esmalte e de dentina, considerando como elementos-alvo, os dentes decíduos. O estudo de mapeamento térmico pôde determinar regiões de operação nas quais não ocorre um aquecimento deletério à polpa dental de dentes decíduos. Com relação aos aspectos micromorfológicos provenientes da interação laser-tecido de dentes decíduos, podemos observar os efeitos colaterais no nível de esmalte mais acentuados do que no nível da dentina. Enquanto a taxa de profundidade de penetração em dentina parece crescer com o progresso do tempo, para o esmalte o comportamento é oposto. O volume ablacionado de forma geral é mais alto em dentina quando comparado ao esmalte, o que resulta em uma taxa de ablação mais alta também. Com relação a remoção de tecidos cariados, o laser de Er:YAG já tem se mostrado como um instrumento seguro e muito eficiente, porém não se trata do único procedimento corriqueiramente realizado na clínica: a remoção ou modificação total ou parcial de restaurações de resinas compostas já polimerizadas tem se tornado uma das práticas mais executadas no dia-a-dia. Sendo assim, empregar esse laser com esse propósito inicia um estudo necessário para conhecermos os aspectos básicos resultantes da ablação a laser das resinas compostas. Os dois últimos experimentos, aqui apresentados, propuseram investigar a taxa de ablação e os aspectos micromorfológicos da ablação com o laser de Er:YAG dos tecidos duros dentais normalmente mais envolvidos em Dentística Restauradora, esmalte e dentina, provenientes tanto de dentes decíduos quanto de permanentes, e também de resinas compostas restauradoras fotopolimerizávies de três tipos: microparticulada, híbrida e compactável. Diferentes condições de trabalho foram utilizadas para analisar a real influência da ablação em resinas compostas com laser de Er:YAG: diferentes energias por pulso (100, 200, 300 e 400mJ) e tempos de imersão em água (zero, 4 e 7 dias). E os resultados nos permitiram concluir que o nível de energia por pulso foi o único fator que de fato pode influenciar a taxa de ablação. O tempo de imersão em água não influenciou de forma estatisticamente significante a taxa de ablação das resinas e os aspectos micromorfológicos resultantes se mostraram dependentes do tipo de estrutura e composição química diferente em cada resina composta aqui escolhida para ser estudada, bem como dos tecidos duros demais. Para finalizar, cruzando os dados obtidos nos dois últimos experimentos empregando o laser de Er:YAG, foi-nos possível encontrar parâmetros para uma ablação que, de fato, possa ser diferencial e seletiva para remoção exclusiva das resinas compostas. A técnica proposta parece ser muito satisfatória para o tecido esmalte, tanto para dentes decíduos quanto para dentes permanentes, enquanto que ainda para dentina não foi possível estabelecer parâmetros. Porém, investigando e entendendo os mecanismos envolvidos, um novo dado foi encontrado com relação a ablação a laser desses compósitos: a água parece não ser a mediadora na ablação pelo laser de Er:YAG, talvez então, esse achado possa agora contribuir para refinar os parâmetros seletivos, considerar o fator característica óptica do tecido-alvo e condições de irradiação, tais como, focalização e diâmetro do feixe laser e presença e quantidade de água no \"spray\", para esmalte e estabelecer aqueles para a dentina, tanto em relação aos dentes decíduos quanto aos permanentes. O objetivo principal foi alcançado, mostrando a viabilidade em preservar ainda mais estruturas de tecidos duros dentais sadios, tratando-os, de fato, e empregando instrumentos que interagem de formas diferenciadas, mostrando uma capacidade em identificar, segundo parâmetros aqui estabelecidos, o material que deva ser removido ou modificado sem resultar em danos colaterais prejudiciais ao órgão dental, e aos tecidos sadios que devem ser sempre conservados íntegros no meio bucal. / Laser is now established as a suitable tool for the selective and precise removal of carious dental tissue. If correctly used, lasers minimize the losses of healthy tissue besides the comfort that it ean promote to patients. The knowledge of basic aspects of laser ablation of dental tissues and materials can lead to the development of a set of parameters that may allow selective removable of deeayed tissues and dissatisfaetory resin preserving healthy dental tissue. Nd:YAG lasers in picosecond regime are not available to dentistry clinical uses yet. Because of that, studies able to allow much information related with this laser system and dental organ are welcome. It could establish safe parameters and rules to its utilization in a brief future in a clinical practice. Three experiments employing Nd: YAG picosecond pulsed laser were executed: thermal map out, micromorphological analysis and ablation rate calculation, all of them considering enamel and dentin, as target-tissues, and, from primary teeth. Thermal map out study resulted in safety operative regions where there are not detrimental heating to dental pulp of primary teeth. Considering micromorphological aspeets as result of laser-tissue interaction in primary teeth, we could observe that collateral damage at the level of enamel more evident than in dentin. While the rate of penetration depth in dentin seems to scale up as the time progress, for enamel the behavior is the opposite. The overall ablated volume is higher in dentin when compared to enamel, which results in a higher ablated rate as well. With relation to decayed tissues, Er: YAG laser has been well established as an efficient and safety tool, however it is not an unique common clinical procedure everyday in offices, total or partial removal or modification of composite resins restorations have became one clinical practice priority. In this manner, to employ this laser system to this proposal seems adequate and starts a necessary research to understand the basic features of laser ablation of composite resin. The last two experiments, presented here, have purposed to investigate ablation rate and micromorphological aspects when dental hard tissues, enamel and dentin, from primary and permanent teeth, are irradiated by Er: YAG laser, besides, photo curable restorative composite resins of three kind of type were irradiated toa: microfiller, hybrid and condensable. Different conditions of work were used to evaluate the real influence of composite resins ablation with Er:YAG laser under different energies per pulse (100, 200, 300 and 400mJ) and immersion time in distilled water (zero, 4 and 7 days). The results allowed concluding that the unique variable factor able to influence statistically the ablation rate of composite was the energy per pulse. The immersion time in water did not influence statistically the ablation rate of resins and the resulted micromorphological aspects showed a dependence considering structure type and chemical composition; they are different to each kind of choose composite studied here, it seems occur even with dental hard tissues. To conclude, combining obtained data from the two cited above experiments with Er:YAG laser, it was possible found parameters to result in a differential and selective ablation, removing exclusively composite resins. The proposed technique seems to be much adequate, however while this idea seems to apply well for enamel of primary and pennanent teeth at the present stage it does not apply well for primary or pennanent dentin. For dentin, the composition and content of water makes the Er: YAG laser ablation equal as superior in rate compared in the three used resins. After understanding the resulted interactions between lasers and substrates, there is an interesting suggestion to search for a more convenient laser system to ablate composite resin. Also, the overall shape of ablation rate indicates that the water flux may well be an important variable to be investigating on the ablation rates. Maybe, like this, this finding could contribute to refine the selective parameters to prevent the useless ablation of enamel and dentin from primary and permanent teeth.

Page generated in 0.1984 seconds