• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 10
  • 9
  • 5
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 71
  • 14
  • 11
  • 11
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Field Oriented Control Of Permanent Magnet Synchronous Motors Using Three-level Neutral-point-clamped Inverter

Mese, Huseyin 01 June 2012 (has links) (PDF)
In this thesis, field oriented control of permanent magnet synchronous motors using three-level neutral-point-clamped inverter is studied. Permanent magnet synchronous motors are used in high performance drive applications. In this study, the permanent magnet synchronous motor is fed by three-level neutral-point-clamped inverter. For three-level neutral-point-clamped inverter different space vector modulation algorithms, which are reported in literature, are analyzed and compared via computer simulations. The voltage balance on dc-link capacitors is also analyzed and a software control method is implemented in conjunction with the space vector PWM modulation, utilized. Nonlinear effects such as dead-time, semiconductor voltage drop and delays in gate drive circuitries also present in neutral-point-clamped inverter. The effects of these nonlinearities are studied and a compensation method for these nonlinear effects is proposed. The theoretical results are supported with computer simulations and verified with experimental results.
52

A Novel Two-parameter Modulation And Neutral Point Potential Control Method For The Three-level Neutral Point Clamped Inverter

Ustuntepe, Bulent 01 December 2005 (has links) (PDF)
In this thesis, the neutral point potential drift/fluctuation of the three-level neutral point clamped inverter is analyzed and a novel control algorithm, the two-parameter PWM method is proposed to confine the neutral point potential variation to a very small range. The two-parameter PWM method provides superior neutral point potential control performance even with small DC bus capacitors. The method is based on PWM pulse pattern modification and requires no additional hardware. Detailed analytical models of the neutral point current and potential as a function of the modulation parameters are established and the neutral point potential behavior is thoroughly investigated. Based on the study, the deficiency of the known methods is illustrated and the two-parameter PWM method is developed and its superior performance demonstrated. The performance of the two-parameter PWM method is verified by means of computer simulations utilizing both the per-PWM-cycle average model and the detailed model of the inverter. The results are supported by laboratory experiments involving both an R-L load and an induction motor drive.
53

Personality and Mood for Non-player Characters: A Method for Behavior Simulation in a Maze Environment

Paige, Noah L 01 December 2020 (has links) (PDF)
When it comes to video games, immersion is key. All types of games aim to keep the player immersed in some form or another. A common aspect of the immersive world in most role-playing games -- but not exclusive to the genre -- is the non-playable character (NPC). At their best, NPCs play an integral role to the sense of immersion the player feels by behaving in a way that feels believable and fits within the world of the game. However, due to lack of innovation in this area of video games, at their worst NPCs can jar the player out of the immersive state of flow with unnatural behavior. In an effort towards making non-playable characters (NPCs) in games smarter, more believable, and more immersive, a method based in psychological theory for controlling the behavior of NPCs was developed. Based on a behavior model similar to most modern games, our behavior model for NPCs traverses a behavior tree. A novel method was introduced using the five-factor model of personality (also known as the big-five personality traits) and the circumplex model of affect (a model of emotion) to inform the traversal of the behavior tree of NPCs. This behavior model has two main beneficial outcomes. The first is emergent gameplay, resulting in unplanned, unpredictable experiences in games which feel closer to natural behavior, leading to an increase in immersion. This can be used for complex storytelling as well by offering information about an NPC's personality to be used in the narrative of games. Secondly, the model is able to provide the emotional status of an NPC in real time. This capability allows developers to programmatically display facial and body expression, eschewing the current time-consuming approach of artist-choreographed animation. Finally, a maze simulation environment was constructed to test the results of our behavior model and procedural animation. The data collected from 100 iterations in our maze simulation environment about our behavior model found that a correlation can be observed between traits and actions, showing that emergent gameplay can be achieved by varying personality traits. Additionally, by incorporating a novel method for procedural animation based on real-time emotion data, a more realistic representation of human behavior is achieved.
54

Nup2 and a Newly Discovered Nuclear Pore Complex Protein, NupA, Function at Mitotic Chromatin Controlled by the NIMA Kinase

Markossian, Sarine W. 27 July 2011 (has links)
No description available.
55

Untersuchung des Dreipunkt – Neutral Point Clamped – Stromrichters mit Spannungszwischenkreis (3L-NPC-VSC) für Niederspannungswindkraftanwendungen

Sprenger, Michael 15 July 2015 (has links) (PDF)
Das Ziel der Arbeit war die Untersuchung eines neuartigen Phasenbausteins mit der Topologie des Dreipunkt – Neutral Point Clamped – Stromrichters mit Spannungszwischenkreis (3L-NPC-VSC) für Windkraftanwendungen. Wichtige Anforderungen an den Phasenbaustein und daraus resultierende Herausforderungen, sowie Lösungen für ausgewählte Teilprobleme werden präsentiert. Um die Vorteile des 3L-NPC-VSC für Hersteller von Windkraftanlagen zugänglich zu machen, ist es sinnvoll, einen neuartigen Phasenbaustein zu entwickeln. Der Phasenbaustein soll einfach in Systeme zu integrieren sein, in denen gegenwärtig Zweipunktstromrichter (2L-VSC) zum Einsatz kommen. Da sich Modulation, Zwischenkreisbalancierung und Kurzschlussschutz vom 2L-VSC unterscheiden, soll der Phasenbaustein diese Herausforderungen eigenständig bewältigen. Die Arbeit beschreibt die Konzeption eines solchen Phasenbausteins und behandelt insbesondere die Modulation, die Zwischenkreisbalancierung und den Kurzschlussschutz des 3L-NPC-VSC. Ein Vergleich verschiedener Modulationsverfahren wurde durchgeführt und die am besten geeigneten Verfahren für die Implementation in den Phasenbaustein ausgewählt. Eine Anforderung war, dass dieser Signale einer übergeordneten Regelung verarbeiten kann, welche für einen 2L-VSC berechnet wurden. Ein Überblick der Zwischenkreisbalancierungsverfahren zeigte, dass nahezu alle den Nachteil einer zusätzlich benötigten Strommessung haben. Die Untersuchung einer neuen an der Professur Leistungselektronik der TU Dresden entwickelten Methode ohne den Bedarf der Strommessung zeigte, dass diese anwendbar ist. Der Algorithmus wurde simuliert, implementiert und experimentell getestet und zeigte gute Resultate. Die Aufgabe eines komplett unabhängigen Kurzschlussschutzes war die schwierigste. Alle möglichen Fehler innerhalb eines Moduls wurden analysiert und kategorisiert. Einige Fehlertypen können innerhalb einer Phase behandelt werden. Entsprechende Algorithmen wurden entwickelt und getestet. Allerdings gibt es Fehlertypen, die nicht durch die Steuerung einer einzelnen Phase behandelt werden können. Eine schnelle Kommunikation zwischen den drei Phasen des Konverters wäre notwendig. Alternativ könnte eine übergeordnete Steuerung diese Fehler behandeln. Zum Schluss wurde ein Demonstrator des Phasenbausteins aufgebaut und experimentell untersucht. Einige Messergebnisse werden gezeigt, um die Funktion zu verifizieren.
56

Untersuchung des Dreipunkt – Neutral Point Clamped – Stromrichters mit Spannungszwischenkreis (3L-NPC-VSC) für Niederspannungswindkraftanwendungen

Sprenger, Michael 07 May 2015 (has links)
Das Ziel der Arbeit war die Untersuchung eines neuartigen Phasenbausteins mit der Topologie des Dreipunkt – Neutral Point Clamped – Stromrichters mit Spannungszwischenkreis (3L-NPC-VSC) für Windkraftanwendungen. Wichtige Anforderungen an den Phasenbaustein und daraus resultierende Herausforderungen, sowie Lösungen für ausgewählte Teilprobleme werden präsentiert. Um die Vorteile des 3L-NPC-VSC für Hersteller von Windkraftanlagen zugänglich zu machen, ist es sinnvoll, einen neuartigen Phasenbaustein zu entwickeln. Der Phasenbaustein soll einfach in Systeme zu integrieren sein, in denen gegenwärtig Zweipunktstromrichter (2L-VSC) zum Einsatz kommen. Da sich Modulation, Zwischenkreisbalancierung und Kurzschlussschutz vom 2L-VSC unterscheiden, soll der Phasenbaustein diese Herausforderungen eigenständig bewältigen. Die Arbeit beschreibt die Konzeption eines solchen Phasenbausteins und behandelt insbesondere die Modulation, die Zwischenkreisbalancierung und den Kurzschlussschutz des 3L-NPC-VSC. Ein Vergleich verschiedener Modulationsverfahren wurde durchgeführt und die am besten geeigneten Verfahren für die Implementation in den Phasenbaustein ausgewählt. Eine Anforderung war, dass dieser Signale einer übergeordneten Regelung verarbeiten kann, welche für einen 2L-VSC berechnet wurden. Ein Überblick der Zwischenkreisbalancierungsverfahren zeigte, dass nahezu alle den Nachteil einer zusätzlich benötigten Strommessung haben. Die Untersuchung einer neuen an der Professur Leistungselektronik der TU Dresden entwickelten Methode ohne den Bedarf der Strommessung zeigte, dass diese anwendbar ist. Der Algorithmus wurde simuliert, implementiert und experimentell getestet und zeigte gute Resultate. Die Aufgabe eines komplett unabhängigen Kurzschlussschutzes war die schwierigste. Alle möglichen Fehler innerhalb eines Moduls wurden analysiert und kategorisiert. Einige Fehlertypen können innerhalb einer Phase behandelt werden. Entsprechende Algorithmen wurden entwickelt und getestet. Allerdings gibt es Fehlertypen, die nicht durch die Steuerung einer einzelnen Phase behandelt werden können. Eine schnelle Kommunikation zwischen den drei Phasen des Konverters wäre notwendig. Alternativ könnte eine übergeordnete Steuerung diese Fehler behandeln. Zum Schluss wurde ein Demonstrator des Phasenbausteins aufgebaut und experimentell untersucht. Einige Messergebnisse werden gezeigt, um die Funktion zu verifizieren.:1 Einleitung 1.1 Motivation 1.2 Zielstellung 1.3 Inhalt der Arbeit 2 Stromrichter für Windkraftanlagen 2.1 Stand der Technik 2.1.1 Zweipunktstromrichter mit Spannungszwischenkreis 2.1.2 Dreipunkt-Neutral-Point-Clamped-Stromrichter mit Spannungszwischenkreis 2.1.3 Kommerziell verfügbare Stromrichter für WKA 2.2 Vollumrichterlösung mit erhöhter Ausgangsspannung 2.2.1 Motivation und Anforderungen 2.2.2 Vereinfachter Vergleich von Zwei- und Dreipunktstromrichtern 2.3 Herausforderungen bei der Realisierung des 3L-NPC-VSC 3 Struktur und Funktion eines neuartigen 3L-NPC-Phasenbausteins 3.1 Struktur und Schnittstellen 3.1.1 Stand der Technik für 3L-NPC Phasenbausteine 3.1.2 Neuartiger 3L-NPC-VSC-Phasenbaustein 3.2 Realisierung 3.2.1 Anforderungen 3.2.2 Technische Realisierung 3.3 Experimentelle Verifikation 3.3.1 Versuchsstand 3.3.2 Messergebnisse 4 Modulation und Zwischenkreisbalancierung eines 3L-NPC-VSC 4.1 Modulationsarten im Überblick 4.1.1 Trägerbasierte Modulation für den 3L-NPC-VSC 4.2 Ausgewählte Modulation für den neuartigen Phasenbaustein 4.2.1 Zweipunktraumzeigermodulation in einem Trägerband 2L-SVM 4.2.2 Dreipunktraumzeigermodulation 3L-SVM 4.3 Stand der Technik bei Zwischenkreisbalancierungsverfahren 4.4 Die direkte Totzeitregelung zur Zwischenkreisbalancierung 4.4.1 Theoretische Grundlagen 4.4.2 Simulative Verifikation der direkten Totzeitregelung 4.4.3 Experimentelle Verifikation der DDTC 5 Kurzschlussschutz eines 3L-NPC-VSC-Phasenbausteins 5.1 Versuchsstand I5.2 Kurzschlussfehler einer 3L-NPC-VSC-Phase 5.2.1 Kategorisierung der Kurzschlüsse 5.2.2 Untersuchte Bauteilfehler innerhalb einer 3L-NPC-VSC-Phase 5.3 Kurzschlussbehandlungsmethoden 5.3.1 Stand der Technik 5.3.2 Schutzmaßnahmen für 3L-NPC-VSC 5.4 Analyse von Kurzschlüssen und Ableitung von Behandlungsmaßnahmen 5.4.1 Fehler eines äußeren IGBTs 5.4.2 Fehler eines inneren IGBTs 5.4.3 Fehler einer Clampdiode 5.5 Maßnahmen zur sicheren Behandlung von Kurzschlüssen in 3L-NPC-VSC 6 Zusammenfassung
57

Operation of Parallel Connected Converters as a Multilevel Converter

Kannan, Vijay 04 June 2018 (has links) (PDF)
The still increasing demand of electrical energy and the rising popularity of renewable energy sources in today's world are two important developments that necessitate the need for innovative solutions in the field of power electronics. Parallel operation of converters is one possible method in trying to bridge an increased current demand. The classical two-level converters, which are the standard in low voltage applications, are rarely adopted in medium and high voltage applications due to the voltage limits on power semiconductor devices. That is one reason for the growing popularity of multilevel converter topologies in medium and high-voltage applications. Although an increase in the number of voltage levels of a multilevel converter has its advantages, there are also challenges posed due to the increased number of switching devices. This has resulted in three-level converters being the most popular compared to converters of higher voltage levels. In this dissertation, the unified operation of parallel connected three-level converter units as a multilevel converter of higher voltage levels is proposed. The mathematical basis for operating parallel connected converter units as a single multilevel converter and the governing equations for such systems are derived. The analysis and the understanding of these equations are important for assessing practicality of the system and devising appropriate control structures. Parallel operation of converter units operating as multilevel converter have their own set of challenges, the two foremost being that of load-sharing and the possibility of circulating and cross currents. Developing solutions to address these challenges require a thorough understanding of how these manifest in the proposed system. Algorithms are then developed for tackling these issues. The control structures are designed and the developed algorithms are implemented. The operation of the system is verified experimentally. / Die weiterhin steigende Nachfrage nach elektrischer Energie und die zunehmende Verwendung erneuerbarer Energiequellen in der heutigen Welt sind zwei wichtige Entwicklungen, die die Notwendigkeit innovativer Lösungen im Bereich der Leistungselektronik erfordern. Der Parallelbetrieb von Stromrichtern ist eine mögliche Methode, um einen erhöhten Strombedarf zu decken. Der klassische Zweipunkt-Spanungszwischenkreisstromrichter, der bei Niederspannungsanwendungen weit verbreitet ist, wird aufgrund der Spannungsgrenzen für Leistungshalbleiterbauelemente zunehmend weniger in Mittel- und Hochspannungsanwendungen eingesetzt. Die begrenzte Spannungsbelastbarkeit der Leistungshalbleiterbauelemente ist ein Grund für die wachsende Beliebtheit von Mehrpunkt-Stromrichtertopologien in Mittelund Hochspannungsanwendungen. Obwohl eine Erhöhung der Anzahl der Spannungsstufen eines Mehrpunkt-Stromrichters Vorteile hat, gibt es auch Herausforderungen und Nachteile aufgrund der erhöhten Anzahl von Leistungshalbleitern. Dies hat dazu geführt, dass der Dreipunkt-Stromrichter die verbreiteste Topologie im Vergleich zu anderen Stromrichtern mit einer höheren Anzahl von Spannungsstufen ist. In dieser Dissertation wird der Betrieb von parallel geschalteten Dreipunkt-Stromrichtereinheiten als ein Mehrpunkt-Stromrichter mit erhöhter Anzahl an Spannungsstufen vorgeschlagen. Die mathematische Basis für den Betrieb von parallel geschalteten Stromrichtereinheiten als ein Mehrpunkt-Stromrichter und die beschreibenden Gleichungen eines solchen Systems werden abgeleitet. Die Analyse und das Verständnis dieser Gleichungen sind wichtig für die Beurteilung der Praktikabilität des Systems und die Erarbeitung geeigneter Regelstrukturen. Der parallele Betrieb von Stromrichtereinheiten hat seine eigenen Herausforderungen, wobei die beiden wichtigsten die Lastverteilung und die Möglichkeit von Kreis- und Querströmen sind. Die Entwicklung von Lösungen zur Bewältigung dieser Herausforderungen erfordert ein gründliches Verständnis dafür, wie sich diese Phänomene in dem vorgeschlagenen System manifestieren. Algorithmen zur Lösung dieser Probleme werden anschlieend entwickelt. Die Regelstrukturen werden entworfen und die entworfenen Algorithmen implementiert. Die Funktionsweise des Systems wird experimentell überprüft.
58

A gramatica e os conhecimentos linguisticos em livros didaticos de lingua portuguesa para o ensino fundamental II (5ª a 8ª series) / Grammar and linguistic knowledge in Portuguese primary school text books II (5th to 8th grades)

Manini, Daniela, 1974- 13 August 2018 (has links)
Orientador: Roxane Helena Rodrigues Rojo / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Estudos da Linguagem / Made available in DSpace on 2018-08-13T06:32:25Z (GMT). No. of bitstreams: 1 Manini_Daniela_M.pdf: 5625566 bytes, checksum: f96d7ca795cb94c8bb5e27a0c46c5359 (MD5) Previous issue date: 2009 / Resumo: O objetivo geral desta pesquisa é analisar como livros didáticos de Português (LDP) atuais, isto é, produzidos após a elaboração dos Parâmetros Curriculares Nacionais de Língua Portuguesa (PCN) e as avaliações do Programa Nacional do Livro Didático (PNLD), desenvolvem o ensino de gramática, frente que gera várias discussões na comunidade acadêmico-científica sobre que gramática ensinar e sob qual metodologia e muitas dúvidas aos professores de Português em exercício. Para tanto, esta dissertação é dividida em quatro capítulos: o primeiro - Gramática: histórico e fundamentação teórica - discorre sobre as primeiras discussões acerca da linguagem na cultura ocidental, de cunho filosófico, e que resultaram no aporte teórico da gramática tradicional, da tradição gramatical e dos estudos da Linguística Moderna. O segundo - A gramática na história da disciplina Língua Portuguesa e do LDP: tratamento didático e propostas teóricometodológicas - apresenta o desenvolvimento da disciplina Língua Portuguesa no Brasil e do LDP, ressaltando, em ambos os casos, o tratamento didático dado à gramática; além disso, apresenta algumas das principais propostas para o ensino de gramática feitas por linguistas brasileiros. O terceiro - Parametrização do ensino de gramática: PCN e PNLD - analisa a(s) proposta(s) para o ensino de gramática feita(s) pelos PCN e traz um breve histórico sobre o PNLD, com destaque para a evolução dos critérios de avaliação dos conhecimentos linguístico-gramaticais ao longo das edições do Programa (1999, 2002, 2005, 2008). O quarto - O que fazem os LDP - análise do corpus selecionado - traz a análise de volumes de três coleções didáticas com perfis distintos em relação à concepção de ensino de língua e ensino de gramática, aprovadas pelo PNLD/2008. / Abstract: The general objective of this research is to investigate how current Portuguese school books (LDP), which have been produced after the elaboration of the National Portuguese Curriculum (NPC) and after being evaluated by the textbook national program (PNLD), develop the teaching of grammar. The teaching of grammar and its different methodologies have been subject of discussion among academics and generates many doubts among Portuguese teachers. This dissertation is divided into four chapters. The first (Grammar: History and theoretical background) deals with he first philosophical discussions about language in Western culture, which provided theoretical background to the traditional grammar, the tradition of grammar and Modern Linguistic studies. The second (Grammar in the history of Portuguese Language teaching and LDP) provides an overview of the development of the subject "Portuguese Language in Brazil" and LDP, giving emphasis to the didactic approach to grammar. Chapter 2 also presents some of the main proposals to the teaching of grammar by Brazilian linguists. The third chapter (Parameters of the teaching of Portuguese: PCN e PNLD) analyses the proposal(s) to the teaching of Portuguese done by PCN. It also presents a brief history of PNLD, focusing on the evolution of the evaluation criteria of linguistic and grammar knowledge throughout the four editions of the Program (1999, 2002, 2005, and 2008). The fourth chapter (What the LDP Do - Analysis of Corpus) analyses the teaching of grammar and language in some volumes of three different text book collections, which have been approved by PNLD/2008. / Mestrado / Lingua Materna / Mestre em Linguística Aplicada
59

Commande d'une éolienne à base de GSAP connectée au réseau électrique par convertisseur multiniveaux

Berhail, Abdelkader January 2020 (has links) (PDF)
No description available.
60

Investigation of Multi-Level Neutral Point Clamped Voltage Source Converters using Isolated Gate Bipolar Transistor Modules

Wilson Veas, Alan Hjalmar 29 April 2019 (has links)
Among the multilevel (ML)-voltage source converters (VSCs) for medium voltage (MV) and high power (HP) applications, the most used power topology is the three level (3L)-neutral point clamped (NPC)-VSC, due to its features such as common direct current (DC)-bus capability with medium point, absence of switches in series-connection, low part count, and straightforward control. The use of MV-insulated gate bipolar transistor (IGBT) modules as power switches offers further advantages like inexpensive gate drivers and survival capability after short-circuit. However, the IGBT modules have a reduced life cycle due to thermal stress generated by load cycles. Despite the advantages of the 3L-NPC-VSC, its main drawback is the uneven power loss distribution among its power devices. To address this issue and to improve other characteristics, more advanced ML converters have been developed. The 3L-active neutral point clamped (ANPC)-VSC allows an improved power loss distribution thanks to its additional IGBTs, which increase the number of feasible zero-states, but needs a loss balancing scheme to choose the proper redundant zero-state and a more complex commutation sequence between states. The 3L-neutral point piloted (NPP)-VSC improves the power loss distribution thanks to the use of series-connected switches between the output terminal and the positive and negative DC-link terminals. Other advanced power topologies with higher amount of levels include the 5L-ANPC-VSC, which has a flying capacitor per phase to generate the additional levels; and the 5L-stacked multicell converter (SMC), which needs two flying capacitors per phase. The goal of this work is to is to evaluate the performance of the aforementioned NPC-type ML converters with common DC-link, included the ones with flying capacitors, in terms of the power loss distribution and the junction temperature of the most stressed devices, which define, along with the nominal output voltage, the maximum power the converter can deliver. A second objective of this work is to describe the commutations of a MV 3L-ANPC-VSC phase leg prototype with IGBT modules, including all the intermediate switching states to generate the desired commutations.:Figures and Tables V Glossary XIII 1. Introduction 1 2. State of the art of medium voltage source converters and power semiconductors 5 2.1. Overview of medium voltage source converters 5 2.1.1. Multilevel Voltage Source Converter topologies 6 2.1.2. Application oriented basic characteristic of IGCTs and IGBTs 10 2.1.3. Market overview of ML-VSCs 11 2.2. IGBT modules for MV applications 12 2.2.1. Structure and Function 12 2.2.2. Electrical characteristics of the IGBT modules 15 2.2.3. Power losses and junction temperatures estimation 17 2.2.4. Packaging 19 2.2.5. Reliability and Life cycle of IGBT modules 21 2.2.6. Market Overview 23 2.3. Summary of Chapter 2 23 3. Structure, function and characteristics of NPC-based VSCs 25 3.1. The 3L-NPC-VSC 25 3.1.1. Power Topology 25 3.1.2. Switching states, current paths and blocking voltage distribution 26 3.1.3. Modulation of three-level inverters 28 3.1.4. Power loss distribution 32 3.1.5. “Short” and “long” commutation paths 33 3.2. The 3L-NPP-VSC 34 3.2.1. Power Topology 34 3.2.2. Switching states, current paths and blocking voltage distribution 35 3.2.3. Power Loss distribution 36 3.3. The 3L-ANPC-VSC 37 3.3.1. Power Topology 37 3.3.2. Switching states, current paths and blocking voltage distribution 38 3.3.3. Commutations and power loss distribution 39 3.3.4. Loss balancing schemes 57 3.4. The 5L-ANPC-VSC 60 3.4.1. Power Topology 60 3.4.2. Switching states, current paths and blocking voltage distribution 61 3.4.3. Commutation sequences 62 3.4.4. Power Loss distribution 70 3.4.5. Modulation and balancing strategies of capacitor voltages 70 3.5. The 5L-SMC 74 3.5.1. Power Topology 74 3.5.2. Switching states, current paths and blocking voltage distribution 75 3.5.3. Commutations and power loss distribution 78 3.5.4. Modulation and balancing strategies of capacitor voltages 80 3.6. Summary of Chapter 3 81 4. Comparative evaluation and performance of NPC-based converters 83 4.1. Motivation and goal of the comparisons 83 4.2. Basis of the comparison 83 4.2.1. Simulation scheme 85 4.2.2. Losses and thermal models for (4.5 kV, 1.2 kA) IGBT modules 86 4.2.3. Operating points, modulation, controllers and general parameters 88 4.2.4. Life cycle estimation 94 4.3. Simulation results of the 3.3 kV 3L-VSCs 97 4.3.1. Loss distribution and temperature at equal phase current 97 4.3.2. Maximum phase current 109 4.3.3. Life cycle 111 4.4. Simulation results of the 6.6 kV 5L and 3L-VSCs 115 4.4.1. Loss distribution and temperature at equal phase current 115 4.4.2. Maximum phase current 120 4.4.3. Life cycle 128 4.5. Summary of Chapter 4 132 5. Experimental investigation of the 3L-ANPC-VSC with IGBT modules 135 5.1. Goal of the work 135 5.2. Description of the 3L-ANPC-VSC test bench 136 5.2.1. Medium voltage stage 136 5.2.2. Gate drivers and digital signal handling 138 5.2.3. Measurement equipment 139 5.3. Double-pulse test and commutation sequences 140 5.3.1. Description of the double-pulse test for the 3L-ANPC-VSC 140 5.3.2. Commutation sequences for the double-pulse test 142 5.4. Commutation measurements 142 5.4.1. Switching and transition times 144 5.4.2. Type I commutations 145 5.4.3. Type I-U commutations 150 5.4.4. Type II commutations 150 5.4.5. Type III commutations 157 5.4.6. Comparison of the commutation times 157 5.4.7. Stray inductances of the “short” and “long” commutations 163 5.5. Summary of Chapter 5 167 6. Conclusions 169 Appendices 173 A. Thermal model of IGBT modules 175 A.1. General “Y” model 175 A.2. “Foster” thermal circuit 177 A.3. “Cauer” thermal circuit 178 A.4. From “Foster” to “Cauer” 179 A.5. Temperature comparison using “Foster” and “Cauer” networks 181 B. The “Rainflow” cycle counting algorithm 183 C. Description of the wind generator example 187 C.1. Simulation models 188 C.1.1. Wind turbine 188 C.1.2. Synchronous generator, grid and choke filter 189 C.1.3. Converters 189 C.2. Controllers 190 C.2.1. MPPT scheme 190 C.2.2. Pitch angle controller 191 C.2.3. Generator side VSC 192 C.2.4. Grid side VSC 193 D. 3D-surfaces of the maximum load currents in NPC-based converters 195 Bibliography 201 Bibliography 201 / Unter den Multilevel-Spannungsumrichtern für Mittelspannungs- und Hochleistungsanwendungen ist die am häufigsten verwendete Leistungstopologie der NPC-VSC, wegen seinen Merkmalen wie die Gleichstrom-Bus fähigkeit mit mittlerem Punkt, das Fehlen von Schaltern in Reihenschaltung, eine geringe Anzahl von Bauteilen und eine einfache Steuerung. Die Verwendung von Bipolartransistor Modulen mit isolierter Gate-Elektrode als Leistungsschalter bietet weitere Vorteile wie kostengünstige Gatetreiber und Überlebensfähigkeit nach einem Kurzschluss. Die IGBT-Module haben jedoch aufgrund der durch Lastzyklen erzeugten thermischen Belastung eine verkürzte Lebensdauer. Trotz der Vorteile des 3L-NPC-VSC ist der Hauptnachteil die ungleichmäßige Verteilung der Leistungsverluste zwischen den Leistungsgeräten. Um dieses Problem zu beheben und andere Eigenschaften zu verbessern, wurden fortgeschrittenere ML-Konverter entwickelt. Das 3L-ANPC-VSC ermöglicht dank seiner zusätzlichen IGBTs eine verbesserte Verlustleistungsverteilung, wodurch die Anzahl der möglichen Null-Zustände erhöht wird, es ist jedoch ein Verlustausgleichsschema erforderlich, um den richtigen redundanten Null-Zustand, und benötigt auszuwählende komplexere Kommutierungssequenz zwischen Zuständen. Das 3L-NPP-VSC verbessert die Verlustleistungsverteilung durch die Verwendung von in Reihe geschalteten Schaltern zwischen der Ausgangsklemme und den positiven und negativen Zwischenkreisklemmen. Andere fortgeschrittene Leistungstopologien mit einer höheren Anzahl von Stufen umfassen den 5L-ANPC-VSC, der pro Phase einen fliegenden Kondensator zur Erzeugung der zusätzlichen Stufen aufweist; und den 5L-SMC, der pro Phase zwei fliegende Kondensatoren benötigt. Das Ziel dieser Arbeit ist es, die Leistung der oben genannten NPC-VSC, einschließlich der mit fliegenden Kondensatoren, hinsichtlich der Verlustleistungsverteilung und der Sperrschichttemperatur der am stärksten beanspruchten Geräte zu bewerten. Diese definieren zusammen mit der Nennausgangsspannung die maximale Leistung, die der Umrichter liefern kann. Ein zweites Ziel dieser Arbeit ist die Beschreibung der Kommutierungen eines MV 3L-ANPC-VSC- Prototyps mit IGBT-Modulen einschließlich aller Zwischenschaltzustände, um die gewünschten Kommutierungen zu erzeugen.:Figures and Tables V Glossary XIII 1. Introduction 1 2. State of the art of medium voltage source converters and power semiconductors 5 2.1. Overview of medium voltage source converters 5 2.1.1. Multilevel Voltage Source Converter topologies 6 2.1.2. Application oriented basic characteristic of IGCTs and IGBTs 10 2.1.3. Market overview of ML-VSCs 11 2.2. IGBT modules for MV applications 12 2.2.1. Structure and Function 12 2.2.2. Electrical characteristics of the IGBT modules 15 2.2.3. Power losses and junction temperatures estimation 17 2.2.4. Packaging 19 2.2.5. Reliability and Life cycle of IGBT modules 21 2.2.6. Market Overview 23 2.3. Summary of Chapter 2 23 3. Structure, function and characteristics of NPC-based VSCs 25 3.1. The 3L-NPC-VSC 25 3.1.1. Power Topology 25 3.1.2. Switching states, current paths and blocking voltage distribution 26 3.1.3. Modulation of three-level inverters 28 3.1.4. Power loss distribution 32 3.1.5. “Short” and “long” commutation paths 33 3.2. The 3L-NPP-VSC 34 3.2.1. Power Topology 34 3.2.2. Switching states, current paths and blocking voltage distribution 35 3.2.3. Power Loss distribution 36 3.3. The 3L-ANPC-VSC 37 3.3.1. Power Topology 37 3.3.2. Switching states, current paths and blocking voltage distribution 38 3.3.3. Commutations and power loss distribution 39 3.3.4. Loss balancing schemes 57 3.4. The 5L-ANPC-VSC 60 3.4.1. Power Topology 60 3.4.2. Switching states, current paths and blocking voltage distribution 61 3.4.3. Commutation sequences 62 3.4.4. Power Loss distribution 70 3.4.5. Modulation and balancing strategies of capacitor voltages 70 3.5. The 5L-SMC 74 3.5.1. Power Topology 74 3.5.2. Switching states, current paths and blocking voltage distribution 75 3.5.3. Commutations and power loss distribution 78 3.5.4. Modulation and balancing strategies of capacitor voltages 80 3.6. Summary of Chapter 3 81 4. Comparative evaluation and performance of NPC-based converters 83 4.1. Motivation and goal of the comparisons 83 4.2. Basis of the comparison 83 4.2.1. Simulation scheme 85 4.2.2. Losses and thermal models for (4.5 kV, 1.2 kA) IGBT modules 86 4.2.3. Operating points, modulation, controllers and general parameters 88 4.2.4. Life cycle estimation 94 4.3. Simulation results of the 3.3 kV 3L-VSCs 97 4.3.1. Loss distribution and temperature at equal phase current 97 4.3.2. Maximum phase current 109 4.3.3. Life cycle 111 4.4. Simulation results of the 6.6 kV 5L and 3L-VSCs 115 4.4.1. Loss distribution and temperature at equal phase current 115 4.4.2. Maximum phase current 120 4.4.3. Life cycle 128 4.5. Summary of Chapter 4 132 5. Experimental investigation of the 3L-ANPC-VSC with IGBT modules 135 5.1. Goal of the work 135 5.2. Description of the 3L-ANPC-VSC test bench 136 5.2.1. Medium voltage stage 136 5.2.2. Gate drivers and digital signal handling 138 5.2.3. Measurement equipment 139 5.3. Double-pulse test and commutation sequences 140 5.3.1. Description of the double-pulse test for the 3L-ANPC-VSC 140 5.3.2. Commutation sequences for the double-pulse test 142 5.4. Commutation measurements 142 5.4.1. Switching and transition times 144 5.4.2. Type I commutations 145 5.4.3. Type I-U commutations 150 5.4.4. Type II commutations 150 5.4.5. Type III commutations 157 5.4.6. Comparison of the commutation times 157 5.4.7. Stray inductances of the “short” and “long” commutations 163 5.5. Summary of Chapter 5 167 6. Conclusions 169 Appendices 173 A. Thermal model of IGBT modules 175 A.1. General “Y” model 175 A.2. “Foster” thermal circuit 177 A.3. “Cauer” thermal circuit 178 A.4. From “Foster” to “Cauer” 179 A.5. Temperature comparison using “Foster” and “Cauer” networks 181 B. The “Rainflow” cycle counting algorithm 183 C. Description of the wind generator example 187 C.1. Simulation models 188 C.1.1. Wind turbine 188 C.1.2. Synchronous generator, grid and choke filter 189 C.1.3. Converters 189 C.2. Controllers 190 C.2.1. MPPT scheme 190 C.2.2. Pitch angle controller 191 C.2.3. Generator side VSC 192 C.2.4. Grid side VSC 193 D. 3D-surfaces of the maximum load currents in NPC-based converters 195 Bibliography 201 Bibliography 201

Page generated in 0.051 seconds