• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 287
  • 265
  • 38
  • 10
  • 9
  • 7
  • 6
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 673
  • 255
  • 143
  • 127
  • 125
  • 118
  • 117
  • 95
  • 84
  • 79
  • 61
  • 58
  • 58
  • 56
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
661

Avaliação tomográfica da expansão rápida da maxila assistida por mini-implantes ortodônticos em indivíduos com maturação óssea avançada. /

Oliveira, Cibele Braga January 2019 (has links)
Orientador: Ary dos Santos-Pinto / Resumo: Este estudo clínico retrospectivo pesquisou, em uma amostra de pacientes com maturação óssea avançada, as alterações esqueléticas e dentárias produzidas com a técnica de expansão rápida da maxila assistida por mini-implantes ortodônticos (MARPE) e comparou com as alterações da expansão rápida maxila assistida cirurgicamente (SARPE). Foi pesquisada também a correlação entre o grau de maturação da sutura palatina mediana (SPM), gênero e idade, com os resultados (sucesso ou insucesso) gerados com a técnica MARPE. Por último, em uma amostra maior de 85 pacientes entre 15 e 58 anos de idade, observou-se a prevalência, por gênero e período etário, dos estágios de maturação da sutura palatina mediana. Para o primeiro objetivo, uma amostra de 17 indivíduos tratados com a MARPE foi comparada com outra amostra de 15 pacientes, com faixa etária semelhante, tratados por meio da SARPE. Tomografia Computadorizada de Feixe Cônico antes(T0) e após(T1) a expansão foram avaliadas. Para o segundo objetivo, a mesma amostra da MARPE foi usada para avaliar as alterações esqueléticas observadas na T0 e T1. Imagens do plano axial da SPM foram extraídas da T0 e classificadas em um dos cinco estágios de maturação sutural. Foi avaliada a taxa de sucesso e insucesso quanto aos fatores idade, gênero e maturação sutural. E, para o terceiro objetivo, foram classificadas imagens axiais de SPM de 85 indivíduos entre 15 e 58 anos, para determinar a prevalência da maturação da SPM em relação ao gênero e idade.... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In a sample of patients with advanced bone maturation, this retrospective clinical study investigated the skeletal and dental changes produced by mini-implants assisted rapid palatal expansion (MARPE) compared with the changes in the surgically assisted rapid palatal expansion (SARPE). The correlation between the maturation stage of the midpalatal suture (MPS), sex and age was also investigated, with the results (success or failure) generated with MARPE. At last, in a larger sample of 85 patients between 15 and 58 years of age, the prevalence of maturation stages of the MPS was observed by sex and age period. For the first objective, a sample of 17 individuals, treated with MARPE, was compared with another sample of 15 patients with similar age group, treated with SARPE. CBCT before (T0) and after (T1) expansion were evaluated. For the second objective, the sample MARPE was used to evaluate the skeletal changes observed in T0 and T1. Images of the axial plane of MPS were extracted from T0 and classified into one of the five stages of suture maturation. The success rate and failure by age, sex and suture maturation were evaluated. And for the third objective, MPS axial images of 85 individuals, aged 15 to 58 years, were classified to determine the prevalence of maturation of MPS in relation to sex and age. The results showed that there is a wide variation in relation to the maturation stage of MPS founded in late adolescents and adults. MARPE showed to be a procedure with good... (Complete abstract click electronic access below) / Doutor
662

Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wires

Sathler-Zanda, Renata 03 July 2012 (has links)
PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi. / OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.
663

Cefalostato virtual-posicionamento inicial para a padronização na marcação de pontos craniométricos em imagens obtidas por tomografia computadorizada, para uso em cefalometria / The Virtual Cephalostat - the preliminar adjustment for standardization of skull orientation in landmarks localization using CT in cephalometric analyses

Vera Lúcia Mestre Rosa 11 September 2009 (has links)
Objetivo: O desenvolvimento da tecnologia em diagnóstico odontológico por imagem através dos Tomógrafos Computadorizados por Feixe Cônico, tornou possível e acessível a avaliação cefalométrica através de reconstruções volumétricas do crânio. Parâmetros baseados em evidências científicas são necessários para implementar o seu uso. Alguns parâmetros utilizados na cefalometria convencional (bidimensional) deverão ser esquecidos, outros deverão ser adaptados, outros, ainda, deverão ser criados. Propomos aqui a criação de um Cefalostato Virtual para orientação do crânio em TC, com a utilização de pontos intracranianos, que são mais estáveis. Também propomos a criação do ponto TS e da linha TS-Pg em substituição ao ponto S e ao eixo Y de crescimento de Downs, respectivamente. Além disso, propomos a linha Ba-Op como referência para casos de assimetria faciais onde não é possível a utilização do plano Horizontal de Frankfurt, em casos, por exemplo, de síndromes que afetem os pontos de referências mais externos. Métodos: 49 crânios pertencentes ao do Museu de Anatomia UNIFESP, foram escaneados em um tomógrafo computadorizado por feixe cônico (TCFC), na clínica ISOOrthographic, São Paulo. As pontuações foram realizadas em dois momentos, com espaçamento de uma semana. Foram calculadas estatisticamente medidas-resumo (média, quartis, mínimo, máximo e desvio padrão). Foram calculadas também as correlações intraclasse e correlações de Pearson entre o Eixo Y (S-Gn) e linha entre os pontos TS e Pg. Resultados: Apesar de se observar uma baixa reprodutibilidade nas coordenadas, para os pontos CE, Pg e Gn, foi observada alta correlação entre as medidas angulares em questão. Para descrever a inclinação do Eixo Y em função da inclinação da Linha TS e Pg adotou-se um modelo de regressão linear simples descrito pela equação abaixo: Ang Sö- Gn = 0,989 Ang TS Pgi i Conclusões: o uso do Cefalostato Virtual na orientação de Crânios em Tomografia Computadorizada é factível e favorece a reprodução do posicionamento craniano; apesar da baixa reprodutibilidade intra observador dos pontos CE, Pg e Gn, novos critérios tridimensionais na definição destes pontos poderiam aumentar a precisão na sua localização; a alta reprodutibilidade intra observador para os pontos Op, TS e N, sugere que os critérios anatômicos próprios das estruturas estudadas favorecem a sua determinação; o ponto TS apresentou maior reprodutibilidade do que o ponto S, embora esta diferença não tenha sido estatisticamente significante, podendo-se substituir o ponto S pelo TS em estudos futuros; existe alta correlação entre a linha entre os pontos TS e Pg e o Eixo Y; a avaliação do comportamento da inclinação da linha orbitomeática (HF) com relação à linha Básio-Opístio sugere que na presença de alterações cranianas este relacionamento propicie auxílio no diagnóstico das alterações craniofaciais. / Objective: The development of new technology in dental diagnosis by cone beam CT (CBCT) image, made possible and accessible the realization of cephalometric evaluation through volumetric reconstructions of the skull. Scientific parameters with evidence-based are needed to implement its use. Some parameters used in conventional cephalometry (2D) maybe need to be forgotten, others should be adapted, and others still to be created. In this research we propose to create a Virtual Cephalostat orientation of the skull in CT, with the intracranial landmarks, because they are more stable. We propose the creation of landmark TS (Tubercle Sella) and the TS-Pg line to replace the landmark S (Sella) and the Y-axis of growth (Downs), respectively. Furthermore, we propose to use the Basion-Opistion line as a reference for cases of craniofacial asymmetry where is not possible to use the Frankfurt horizontal plane, as in some cases of syndromes that affects the most external landmarks. Methods: 49 skulls of Anatomy Museum of UNIFESP Federal University of São Paulo, were scanned in a CBCT. The analyses were performed in 2 stages, within 1-week space. Statistics measurements were calculated (mean, quartiles, minimum, maximum and standard deviation). We also calculated the intraclass correlations (ICC) and the Pearson correlations between the Y axis (S-Gn) and the line between landmarks TS-Pg. Results: Even if there is a low reproducibility in the coordinates for landmarks EC (Ethmoidal Crest), Pg and Gn it was observed a high correlation between the angular measures in question. To describe the inclination of the Y axis according to the slope of the line adopted TS and Pg a simple linear regression model is used, showed by the equation bellow: Ang Sö- Gn = 0,989 Ang TS Pgi i Conclusions: The use of the Virtual Cephalostat in orientation of skulls using CBCT is feasible and facilitates the reproduction of the skull position, despite the low intra observer reproducibility of landmarks EC, Pg and Gn, new 3D criteria in the definition of these landmarks could increase the precision in its location. The high intra observer reproducibility at the landmarks Op, N and TS, suggests that the anatomical criteria themselves promote their reliability; The TS landmark showed a higher reproducibility than the S landmark, even though the difference was not statistically significant, and it should be replaced by the landmark TS in future studies. There is a high correlation between the TS - Pg line and Y-axis. The relationship between the slope of the HF plane and Ba -Op line suggests that in the presence of the alteration of morphology in craniofacial structure, this relationship offer help in the diagnosis of craniofacial changes.
664

Quality of life in relation to orthodontic problems among adolescent children in the city of Chennai, India / Gyvenimo kokybės perspektyvos atsižvelgiant į vaikų ir paauglių ortodontines problemas Chennai mieste, Indija

Prakash, Prashanth 10 June 2014 (has links)
AIM: To evaluate the prevalence of orthodontic problems and quality of life in relation to orthodontic problems among adolescent children in the city of Chennai, India. OBJECTIVES: To analyze the differences in the need for orthodontic treatment among children in the public and private schools; to analyze the need for orthodontic treatment among the various socioeconomic groups; to evaluate the Quality of Life (QoL) among the children; to analyze the relationship between Quality of Life (QoL) and the need for orthodontic treatment. METHODS: 200 children participated in the study, out of which 100 were from the private school and 100 from the public school from the city of Chennai, India. Two sets of questionnaires were used for the study, one was filled by the children and the other was filled by the researchers and trained dental assistants after doing a thorough dental examination and asking questions from the participants. This was carried out according to the recommendations of WHO oral health assessment. Statistical data was collected, recorded and analyzed using the software SPSS 17.0 for Windows. RESULTS: The private school children had more orthodontic problems than the public school children (49% and 44% respectively). The need for Orthodontic Treatment was the highest in children under the rich category (56.4%), followed by the children under the poor category (45.3%) and is least among the children under the average category (44.4%). The Quality of Life was... [to full text] / TIKSLAS: Įvertinti ortodontinio problemas ir perspektyvas atsižvelgiant į ortodontinio problemas tarp paauglių vaikų mieste Chennai, Indija. TIKSLAI: Analizuoti skirtumus reikalingas Ortodontinis gydymas tarp vaikų, viešąsias ir privačias mokyklas; analizuoti kad ortodontinio gydymo tarp įvairių socialinių ir ekonominių grupių; vertinti gyvenimo kokybę (QoL) tarp vaikų; išanalizuoti ryšį tarp gyvenimo kokybę (QoL) ir ortodontinio gydymo poreikį. METODAI: 200 vaikai dalyvavo tyrime, iš kurių 100 buvo privati mokykla ir 100 iš viešųjų mokyklų iš miesto Chennai, Indija. Vienų, ir klausimynų buvo naudojami tyrimo, vienas buvo užpildyti vaikų ir kitų buvo užpildyti mokslininkų ir apmokyti dantų padėjėjai po daro dantų nuodugniai ir užduoti klausimus iš dalyvių. Tai buvo daroma pagal PSO burnos sveikatos vertinimo rekomendacijas. Statistiniai duomenys buvo renkami, įrašytos ir analizuoti naudojant SPSS 17,0 programinė įranga Windows. REZULTATAI: Privačios mokyklos vaikai turėjo daugiau ortodontinio problemų nei valstybinių mokyklų vaikai (atitinkamai 49 % ir 44 %). Ortodontinio gydymo poreikis buvo didžiausias vaikams pagal turtingas kategorija (56.4 %), po to vaikai iki prastos kategorija (45.3 %) ir kas tarp vaikų iki vidutinės kategorijos (44.4 %). Gyvenimo kokybė buvo nustatyta, kad geriau tarp vaikų, privačios mokyklos nei valstybinėse mokyklose (90,6 % ir 89.0 % atitinkamai). Vaikams, kurie neturėjo nei gera gyvenimo kokybė turėjo mažai arba visai nėra ortodontinio kai... [toliau žr. visą tekstą]
665

BENEFÍCIOS DO TRATAMENTO TARDIO DA MÁ OCLUSÃO DE CLASSE II COM OS APARELHOS FORSUS E TWIN FORCE

Corrêa, Heleny Gomes 31 March 2011 (has links)
Made available in DSpace on 2016-08-03T16:31:16Z (GMT). No. of bitstreams: 1 RESUMO.pdf: 50043 bytes, checksum: a040447349c295ed19468127953c7944 (MD5) Previous issue date: 2011-03-31 / O objtivo deste estudo pros
666

Reabsorção radicular apical em decorrência do tratamento ortodôntico detectada por meio de tomografia computadorizada de feixe cônico / Apical root resorption due to orthodontic treatment detected by cone beam computed tomography

CASTRO, Iury Oliveira 17 February 2012 (has links)
Made available in DSpace on 2014-07-29T15:21:58Z (GMT). No. of bitstreams: 1 Dissertacao Iury Oliveira Castro.pdf: 1108480 bytes, checksum: 128afd0de2b97f12fc1f7b511b16af6f (MD5) Previous issue date: 2012-02-17 / Objective: To determine the frequency of apical root resorption in different tooth groups after the end of orthodontic treatment, detected by cone beam computed tomography. Methodology: Images of cone beam computed tomography of 30 patients who had Class I malocclusion and crowding were obtained before and after orthodontic movement. The treatment with fixed appliances was developed based on the Roth prescription. A total of 1256 dental roots were evaluated based on the measurement of linear length between root apex and incisal/cusp. It was an epidemiological, prospective, longitudinal and intra individual study. Results: The mean age of patients was 13 years, 11 were male and 19 female. One hundred percent of the patient presented teeth with apical root resorption, 46% of the roots avaluated was affected. The teeth showed higher extent of apical root resorption were upper lateral incisors, lower lateral, upper central, lower central, upper and lower first molars (p <0.05). By analyzing the roots individually, there was a high frequency of apical root resorption in maxillary central incisors (73%), maxillary lateral incisors (73%), mandibular central incisors (72%), mandibular lateral incisors (70%) and distal roots of mandibular first molar (63%). There was a low frequency of apical root resorption in the buccal roots of the maxillary second premolar (17%), distovestibular and palatine roots of maxillary second molar (18%) and distal roots of mandibular second molar (20%). The results showed that there was no association between frequency of resorption and gender (p> 0.05). The number of resorption did not vary with age when evaluated at age 11 to 16 years (p> 0.05). Conclusion: The apical root resorption was detected in 46% of the roots of teeth submitted to orthodontic treatment, diagnosed by cone beam computed tomography. The most affected teeth were central incisors, lateral and first molars. / Objetivo: Determinar a frequência de reabsorção radicular apical em diferentes grupos dentários após o término do tratamento ortodôntico identificada por meio de tomografia computadorizada de feixe cônico. Metodologia: Imagens de tomografia computadorizada de feixe cônico de 30 indivíduos, que apresentavam má oclusão Classe I e apinhamento, foram obtidas antes e depois da movimentação ortodôntica. O tratamento foi desenvolvido com aparelhos fixos com base na prescrição de Roth. Um total de 1256 raízes dentárias foram avaliadas com base na mensuração do comprimento linear entre ápices radiculares e incisais/cúspides. Resultados: A idade média dos pacientes foi de 13 anos, 11 eram do gênero masculino e 19 do feminino. Cem por cento dos pacientes apresentaram dentes com reabsorção radicular apical, com uma frequência de 46% de raízes afetadas. Os dentes que apresentaram maior extensão de reabsorção radicular apical foram incisivos laterais superiores, laterais inferiores, centrais superiores, centrais inferiores, primeiros molares superiores e inferiores (p < 0,05). Ao analisar as raízes individualmente verificou-se uma elevada frequência de reabsorção radicular apical em incisivos centrais superiores (73%), laterais superiores (73%), centrais inferiores (72%), laterais inferiores (70%) e raízes distais de primeiro molar inferior (63%). Verificou-se uma frequência baixa de reabsorção radicular apical em raízes vestibular do segundo pré-molar superior (17%), distovestibulares e palatinas de segundo molar superior (18%) e distal de segundo molar inferior (20%). Os resultados mostraram que não houve associação entre a frequência de reabsorção e gênero (p > 0,05). O número de reabsorção não variou com a idade quando avaliada a faixa etária de 11 a 16 anos (p > 0,05). Conclusão: A reabsorção radicular apical foi detectada em 46% das raízes de dentes submetidos a tratamento ortodôntico, por meio de tomografia computadorizada de feixe cônico. Os dentes mais afetados foram incisivos centrais, laterais e primeiros molares inferiores.
667

Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wires

Renata Sathler-Zanda 03 July 2012 (has links)
PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi. / OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.
668

Three-dimensional image analysis for quantification of tooth movements and landmark changes

Li, Shuning 11 December 2013 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Quantification of treatment outcomes (tooth displacement and bony changes) is the key to advance orthodontic research and improve clinical practices. Traditionally, treatment outcome were quantified by using two-dimensional (2D) cephalometric analysis. However, there are problems inherent in 2D analysis, such as tracing errors and inability to detect side-effects. Thus, a reliable three-dimensional (3D) image analysis method for treatment outcome quantification is of high interest. Systematic 3D image analysis methods were developed for digital dental cast models and Cone-Beam Computed Tomography (CBCT) models. A typical analysis procedure includes image reconstruction, landmarks identification, coordinate system setup, superimposition, and displacement or change calculation. The specified procedures for maxillary teeth displacements and anatomical landmarks movements were presented and validated. The validation results showed that these procedures were accurate and reliable enough for clinical applications. The 3D methods were first applied to a human canine retraction clinical study. The purposes of this study were to quantify canines and anchorage tooth movements, and to compare two commonly used canine retraction strategies, controlled tipping and translation. The canine results showed that (1) canine movements were linear with time; (2) the initial load system was not the only factor that controlled the canine movement pattern; and (3) control tipping was significantly faster than translation. The anchorage tooth results showed that (1) anchorage losses occurred even with transpalatal arch (TPA); (2) there was no significant difference in anchorage loss between the two treatment strategies; and (3) compared with removable TPA, fixed TPA appliance can significantly reduce the amount of anchorage loss in the mesial-distal direction. The second clinical application for the 3D methods was a mandibular growth clinical trial. The purposes of this study were to quantify skeletal landmark movements, and compare two widely used appliances, Herbst and MARA. The results showed that (1) the Herbst appliance caused mandibular forward movement with backward rotation; and (2) the treatment effects had no significant differences by using either Herbst or MARA appliances. The two clinical applications validated the methods developed in this study to quantify orthodontic treatment outcomes. They also demonstrated the benefits of using the 3D methods to quantify orthodontic treatment outcomes and to test fundamental hypotheses. These 3D methods can easily be extended to other clinical cases. This study will benefit orthodontic patients, clinicians and researchers.
669

Effets de la vitamine D sur la morphométrie osseuse et la stabilité du mouvement dentaire orthodontique (MDO) chez le rat

Gratton, Marie-Pascale 04 1900 (has links)
Introduction : La vitamine D (VitD) maintient la santé osseuse et influence le mouvement dentaire orthodontique (MDO). L’objectif était d’évaluer l’effet de la VitD sur la morphométrie osseuse, puis sur la vitesse et la stabilité du MDO. Méthode : 32 rats Sprague Dawley mâles ont été assignés à deux groupes expérimentaux, traités avec la VitD par gavage (systémique) ou par injection (locale), et deux groupes contrôles respectifs traités avec un tampon phosphate salin (PBS) pour 47 jours. Le MDO était effectué pendant 7 jours avec un ressort NiTi attaché entre la première molaire supérieure et les incisives. Un scan Micro-CT était réalisé à 5 temps : T0 (avant l’administration de VitD), T1 (début du MDO), T2 (fin du MDO), T3 (7 jours post-MDO), T4 (30 jours post-MDO). La vitesse et la stabilité du MDO étaient évaluées. La morphométrie osseuse a été analysée via la densité minérale osseuse (BMD), le pourcentage de volume d’os (BV/TV), la porosité totale (Po(tot)), le facteur du patron trabéculaire (Tb.Pf), l’index de structure du modèle (SMI) et la densité de connectivité (Conn.Dn). Résultats : Le groupe VitD systémique a montré une vitesse diminuée du MDO, mais une récidive inférieure au contrôle ainsi qu’une augmentation de la BMD et du BV/TV, et une diminution de la Po(tot) (p<0.05). La structure osseuse apparaissait plus fragmentée et présentait une Conn.Dn plus basse (p<0.05). Aucune différence n’a été trouvée entre le groupe administration locale de VitD et les autres groupes. Conclusion : L’administration systémique de VitD a engendré une diminution de vitesse du MDO en induisant plus de résistance, mais a aussi contribué à une meilleure stabilité grâce à une densité osseuse plus élevée. / Introduction: Vitamin D (VitD) maintains bone health and may influence the orthodontic tooth movement (OTM). The objective was to evaluate VitD effect on bone morphometry, and on the rate and stability of OTM. Methods: 32 male Sprague Dawley rats were assigned into two experimental groups, treated with VitD by gavage (systemic) or by injection (local), and two respective control groups treated with phosphate-buffered saline (PBS) for 47 days. OTM was performed for 7 days with a NiTi coil bonded between the upper first molar and incisors. Micro-CT scanning was performed at 5 time-points: T0 (before administration of VitD), T1 (start of OTM), T2 (end of OTM), T3 (7 days post-OTM) and T4 (30 days postOTM). Rate and stability of OTM were assessed. Bone morphometry was analyzed by bone mineral density (BMD), percent bone/volume (BV/TV), total porosity (Po(tot)), trabecular pattern factor (Tb.Pf), structure model index (SMI) and connectivity density (Conn.Dn). Results: The systemic VitD group showed a lower OTM rate, but also a lower relapse than control (p<0.05). It also demonstrated an increase of BMD and BV/TV, and a decrease of Po(tot) (p<0.05). The bone structure appeared more fragmented and presented lower Conn.Dn than the control (p<0.05). No statistical difference was found between VitD local administration and the other groups for the rate and stability of OTM, or for the bone morphometry. Conclusion: The systemic administration of VitD caused a decrease of OTM rate by generating more bone resistance, but also contributed to a greater stability due to a higher bone mineral density.
670

Efecto de dos bebidas refrescantes en la adhesión de brackets. Observación mediante microcopio electrónico de barrido del esmalte intacto y sellado por una resina tras la exposición a dichas bebidas

Navarro Garre, Rául 24 February 2012 (has links)
OBJETIVO: Evaluar el efecto de Coca-Cola® y Schweppes® Limón en la fuerza adhesiva, el adhesivo remanente y la microfiltración debajo de los brackets. Examinar mediante microscopio electrónico de barrido (MEB) el efecto de estas bebidas en el esmalte intacto y esmalte sellado. MÉTODO: Se cementaron 120 brackets en incisivos bovinos y se dividieron 1) grupo control, 2) Coca-Cola®, 3) Schweppes® Limón. Los dientes fueron sumergidos en las bebidas tres veces al día (15 minutos) durante 15 días. La fuerza de adhesión fue medida con una máquina universal de ensayos y el adhesivo remanente, utilizando un equipo de análisis de imagen. La microfiltración en la interfase esmalte-adhesivo y adhesivo-bracket se determinó utilizando azul de metileno. Para las observaciones al MEB se utilizaron 108 dientes. RESULTADOS: No se encontraron diferencias significativas en la fuerza adhesiva y el adhesivo remanente entre grupos. La microfiltración en la interfase esmalte-adhesivo para Coca-Cola® y Schweppes® Limón fue significativamente mayor que para el grupo control. En la interfase adhesivo-bracket la microfiltración de Coca-Cola® fue mayor que el grupo control, mientras que la microfiltración de Schweppes® Limón no difirió significativamente ni de Coca-Cola® ni del grupo control. Las bebidas produjeron erosión del esmalte y pérdida del material adhesivo. / Objective: To evaluate the effect of Coca-Cola® and Schweppes®-Limón on bond strength, adhesive remnant and microleakage beneath brackets. To examine by Scanning Electron Microscope (SEM) the effect of these drinks on intact and sealed enamel. Methods: 120 brackets were bonded to bovine incisors and divided into: 1)Control-group; 2)Coca-Cola®; 3)Schweppes®-Limón. The teeth were submerged in the drinks 3 times/day (15 minutes) during fifteen days. Shear bond strength was measured with a universal test machine, and adhesive remnant using image analysis equipment. Microleakage at the enamel-adhesive and adhesive-bracket interfaces was detected using methylene blue. 108 teeth were used to examine by SEM the effect of the drinks on intact and sealed enamel. Results: No significant differences were found in bond strength and adhesive remnant between groups. Microleakage at the enamel-adhesive interface for Coca-Cola® and Schweppes®-Limón was significantly greater than for the control. At the adhesive-bracket interface microleakage was significantly greater with Coca-Cola® than with the control whilst microleakage with Schweppes®-Limón did not differ significantly from either Coca-Cola® or the control. The drinks produced enamel erosion and loss of adhesive.

Page generated in 0.0365 seconds