51

Proteinograma sérico e sua relação com a reparação óssea em coelhos (Oryctolagus cuniculus) submetidos à ostectomia parcial do rádio /

Calciolari, Karina. January 2019 (has links)
Orientador: Bruno Watanabe Minto / Resumo: Os traumas ósseos desencadeiam resposta inflamatória aguda e consequentemente alteram a concentração sérica das proteínas de fase aguda (PFAs), podendo essas serem um parâmetro para avaliação da evolução do processo inflamatório relacionado a ortopedia. Objetivou-se avaliar a efetividade da mensuração de PFAs como um biomarcador laboratorial para diagnóstico e acompanhamento da inflamação relacionada a regeneração óssea. Foram utilizados 22 coelhos, machos jovens sendo realizado ostectomia parcial do osso do rádio direito. Para acompanhamento da evolução do processo inflamatório foram realizados hemograma, mensuração de PFAs (Albumina, Ceruloplasmina, Haptoglobina, Proteína C Reativa e Transferrina) e acompanhamento radiológico. Foi observado a melhor correlação da haptoglobina e da transferrina junto ao processo inflamatório e achados radiológicos frente as demais PFAs mensuradas. A haptoglobina apresentou pico máximo 24 horas dos pós operatório e a transferrina após 36 horas, entretanto essa última PFA já mostrou indícios de alteração (diminuiu) já nas primeiras 6 horas do pós-cirúrgico, antecipadamente a resposta leucocitária. Conclui-se que o conjunto haptoglobina, transferrina e leucograma apresentaram resultados promissores ao diagnóstico e prognóstico de processos inflamatórios relacionados a ortopedia. / Doutor
52

Análise biomecânica óssea e tendínea de cadáveres de cães preparados quimicamente visando ao ensino e pesquisa da ortopedia veterinária /

Rocha, Thiago André Salvitti de Sá. January 2020 (has links)
Orientador: Fabrício Singaretti de Oliveira / Resumo: Para que não ocorra deterioração dos tecidos, as peças anatômicas devem ser fixadas, mantendo os tecidos firmes e protegidos. O formaldeído é o fixador e conservante mais utilizado, porém extremamente tóxico. Estudos atuais visam utilizar soluções alternativas ao formaldeído, e empregam a glicerina, solução de Larssen, de Larssen modificada, de Laskowski, entre outras, visando ao ensino. Objetivou-se, com este trabalho, avaliar por meio de ensaio biomecânico, a fixação de cadáveres de cães com solução de álcool glicerinado e de sal de cura para utilização no ensino e pesquisa da ortopedia veterinária. Foram estabelecidos 5 grupos (10 animais cada): G0 (controle/fresco) G30 (30 dias de conservação), G60 (60 dias conservação), G90 (90 dias conservação) e G120 (120 dias conservação). Exceto o G0, todos os demais grupos foram conservados sob refrigeração após a fixação. Foram avaliados ambos antímeros do úmero, rádio, ulna, fêmur e tíbia por meio de ensaio biomecânico de cisalhamento em três pontos e teste de tração do tendão calcâneo comum, além de avaliação qualitativa da coloração da medula óssea, visando identificar qual grupo apresentava qualidade tecidual mais próxima ao G0. A análise estatística das médias da força máxima de ruptura dos ossos longos e tendão calcâneo comum não apresentou diferença significativa, evidenciando ausência de alteração na qualidade tecidual durante quatro meses de conservação. A análise estatística dos dados qualitativos demonstrou tempo de cons... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In order to avoid tissue deterioration, anatomical specimens must be fixed, because this keeps tissues firm and protected. Formaldehyde is the most commonly fixative and preservative solution used, but it is harmful to health. Current studies apply alternative solutions to formaldehyde and use glycerin, the Larssen solution, the modified Larssen solution, the Laskowski´s, among others for the teaching. The aim of this research was to analyze the fixation of dogs´ corpses with glycerinated alcohol and curing salt for the veterinary orthopedic teaching. Five groups were established (10 animals each): G0 (control/fresh), G30 (30 days of conservation) G60 (60 days), G90 (90 days), G120 (120 days). Both antimere of humerus, radius, ulna, femur, tibia and the common calcaneal tendon were analyzed by 3-point shear biomechanical assay, traction test, besides qualitative evaluation of bone marrow staining, aiming identification of the group with best tissue quality and close to G0. The maximum rupture force in long bones and the common calcaneus tendon did not present significant difference, demonstrating there was no tissue alteration during conservation (four months). The qualitative data demonstrated a 30 to 60 day-time as the ideal for conservation of bone marrow. The anatomical technique applied did satisfy the conservation, with no significant changes in long bones´ and common calcaneus tendon´s biomechanical properties for a considerable time (up to four months), besides a sati... (Complete abstract click electronic access below) / Doutor
53

Análise biomecanica de placa modificada de tplo em modelo experimental de falha óssea proximal em tíbias sintéticas caninas /

Sembenelli, Guilherme. January 2017 (has links)
Orientador: Luis Gustavo Gosuen Gonçalves Dias / Banca: Antonio Carlos Shimano / Banca: Bruno Watanabe Minto / Resumo: O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar a eficácia da estabilização óssea proporcionada pelo implante desenvolvido comparativamente a outros dois métodos convencionais de fixação óssea (placa bloqueada e placa bloqueada associada a pino intramedular). Por meio de estudos biomecânicos, avaliaram-se as construções às forças de torção, flexão craniocaudal, flexão mediolateral e compressão axial. Foram utilizadas sessenta tíbias sintéticas dividas em três grupos. O Grupo 1 (placa TPLO modificada), o Grupo 2 (placa bloqueada) e o Grupo 3 (placa bloqueada associada a pino intramedular) foram qsubdivididos em quatro grupos de cinco tíbias. Os ensaios foram realizados até a falha da montagem (implantes e/ou tíbia) e os resultados obtidos comparados entre os grupos. As variáveis estudadas foram analisadas sob delineamento inteiramente casualizado no esquema fatorial 3 por 4 com 5 repetições para cada combinação do esquema fatorial. Os resultados foram submetidos à análise de variância e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. No ensaio de compressão axial houve diferença significativa em relação a variável força máxima em que o Grupo 3 obteve maior média, não havendo diferença significativa entre os Grupos 1 e 2. Todas as montagens falharam devido à flexão da placa na região de falha no corpo de prova. No ensaio de flexão em três pontos craniocaudal houve diferença significativa em relação às três vari... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to develop modified TPLO locked plate and to evaluate the effectiveness of stabilization provided by the implant developed compared to two other conventional methods of stabilization (locked plate and plate-rod). Through biomechanical studies the constructions were evaluated to craniocaudal and mediolateral bending, axial compression and torsional forces. Sixty synthetic tibias were used divided into three groups. Group 1 (modified TPLO plate), Group 2 (locked plate) and Group 3 (plate-rod) were subdivided into four groups of five tibiae. The tests were perfomed until failure of the construction (implants / tibia) and the results compared between the groups. The variables studied were analyzed under a completely randomized design in the factorial scheme 3 by 4 with 5 replicates for each combination of the factorial scheme. The results were submitted to analysis of variance and the means compared to each other by the Tukey test at 5% probability. In the axial compression test there was a significant difference in relation to the variable maximum force in which Group 3 obtained higher mean, not having significant difference between Groups 1 and 2. All constructions failed due to plate bending in the gap region of the synthetic tibia. In the three-point craniocaudal flexion test there was a significant difference in relation to the three variables studied. In the variable force maximum G2> G3 = G1, in the variable deflection G3> G1 = G2 and in the varia... (Complete abstract click electronic access below) / Mestre
54

Placas em ponte para tratamento de falhas segmentadas em mandíbulas de cães: projetos e desenvolvimento

Freitas, Elisângela Perez de [UNESP] 03 May 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-03Bitstream added on 2014-06-13T20:01:38Z : No. of bitstreams: 1 freitas_ep_dr_botfmvz_parcial.pdf: 61955 bytes, checksum: c73461c83ca08189187b1f7319894dbd (MD5) Bitstreams deleted on 2015-06-30T11:22:15Z: freitas_ep_dr_botfmvz_parcial.pdf,. Added 1 bitstream(s) on 2015-06-30T11:23:09Z : No. of bitstreams: 1 000692140_20171230.pdf: 61770 bytes, checksum: e3a4230a4a6154c61333b89fa1d606dd (MD5) Bitstreams deleted on 2018-01-02T17:04:43Z: 000692140_20171230.pdf,. Added 1 bitstream(s) on 2018-01-02T17:05:47Z : No. of bitstreams: 1 000692140.pdf: 550354 bytes, checksum: b65602f73ff7f1e1282e04922e4797bc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O trabalho teve por objetivos desenvolver placa em ponte bloqueada para a reconstrução de defeito ósseo segmentar em mandíbula de cães e validar o projeto por meio de análise pelo método de elementos finitos e ensaios biomecânicos. Inicialmente realizou-se a tomografia computadorizada da cabeça de quatro cães das raças Rottweiler, Doberman, Boxer e Poodle. Os dados obtidos em DICOM foram convertidos em objeto tridimensional pelo software Mimics 13.1 e usados na confecção do projeto das placas. Foram confeccionados, para cada raça, seis protótipos de mandíbula com defeito ósseo de tamanho de 1,5 vezes o diâmetro do corpo mandibular direito na área do primeiro pré-molar. A reconstrução mandibular foi feita com placa em ponte de titânio puro e parafusos (Ti 6Al 4V) monocorticais bloqueados, sendo um modelo para os cães de porte grande (Rottweiler e Doberman) e médio (Boxer) e outro para os de porte pequeno (Poodle). Os ensaios biomecânicos mostraram que o sistema placa-mandíbula resistiu além das forças de mastigação para todos os portes de cães e validaram os projetos das placas. O método de elementos finitos mostrou que o fator de segurança foi superior a 2. Foi possível concluir que as placas em ponte projetadas com geometria diferenciada e parafusos bloqueados monocorticais apresentam resistência mecânica suficiente para suportar os defeitos ósseos induzidos e são capazes de suportar pelo menos 5 vezes o valor da força de mordida para cada porte de cão estudado / The aim of this study was to develop locked bridging plate to be used in segmental mandible defect in dogs, and to validate the project by finite element modeling (FEM) and mechanical testing. Computed tomography (CT) of the head of four dogs from Rottweiler, Doberman, Boxer and Poodle breeds were performed. The images were reconstructed in 3D format with specialized software (Mimics 13.1) and used to develop the plate project. For each breed dog, six mandible prototypes with a bone defect of 1.5 times the diameter of the right mandibular body at the first molar area were made. The mandibular reconstruction was performed with bridging plate in pure titanium and locked monocortical screws, being one design to large (Rottweiler e Doberman) and medium (Boxer) breed dogs, and another to small breed dog (Poodle). The mechanical testing showed that plate-mandible system resisted biting forces for all dogs and it validated the plate designs. FEM showed the security factor was higher than 2. In conclusion, the bridging plates designed with differentiated geometry and monocortical loc ked screws showed mechanical resistance to support the induced bone defects and were able to support at least 5 times the value of the bite force for each evaluated dog
55

O efeito da orientação do parafuso bloqueado nas propriedades biomecânicas da placa S.P.S. Free-Block em corpos de prova nao osteoporóticos

Agurto Merino, Marisol Karin [UNESP] 08 December 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-12-08Bitstream added on 2014-06-13T20:50:48Z : No. of bitstreams: 1 agurtomerino_mk_me_botfmvz.pdf: 723207 bytes, checksum: 7df2268c52113d40d7dddacaadc2bf5e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Entre os modelos de fixadores internos há um sistema denominado S.P.S. Free-Block, cuja placa possui um anel trava que possibilita o bloqueio do parafuso em angulações variadas. Visto os poucos estudos biomecânicos com o sistema, o presente trabalho avaliou a influência da orientação do parafuso bloqueado na resistência da montagem. Foram usados cilíndricos sintéticos, nos quais foram promovidas falhas segmentares de 10 mm. As placas de aço com 7 furos (2 DCP e 5 bloqueados) foram montadas de acordo com a posição dos parafusos nos orifícios bloqueados: Grupo 1 – parafusos monocorticais posicionados em 90º, Grupo 2 – parafusos monocorticais posicionados de forma inclinada em 20º. Os parafusos dos orifícios DCP foram aplicados rotineiramente em posição neutra e de maneira bicortical. Na região da falha segmentar o orifício do parafuso bloqueado situado no centro da placa entre os DCP foi mantido livre. Em cada grupo, seis montagens foram testadas até a falência, três em flexão em quatro pontos e três em compressão axial, para determinar as cargas de teste. Posteriormente, em cada grupo, 14 montagens foram testadas até a falência em fadiga, sete em flexão e sete em compressão. Pela análise estatística não houve diferença na rigidez das construções entre os Grupos 1 e 2, tanto nos testes estáticos como nos de fadiga. Conclui-se assim que, em modelo de falha segmentar, o posicionamento do parafuso monocortical bloqueado não influenciou a resistência mecânica das montagens / Among the locked internal fixators is one denominated S.P.S. Free-Block that was designed with a locking ring that allows the screw to be locked and positioned obliquely. Due to the paucity of biomechanical studies on this system, the present work aimed to evaluate the influence of locked screw orientation on the resistance of the S.P.S. Free-Block plate. Non-osteoporotic synthetic bone cylinders with 10 mm fracture gap were used. Seven-hole 3.5 mm stainless steel plates (two DCP holes and five locked holes) were assembled according to the orientation of the blocked screws: monocortical screws positioned at 90º to the long axis of the cylinder (G1), and monocortical screws positioned at 20º to its cylinder long axis (G2). In both groups, DCP hole screws were positioned bicortically and neutrally. In the region of the fracture gap, the locked screw hole at the plate’s center was unfilled. For each group, six specimens were tested until failure, three in bending and three in compression, to determine the loads for fatigue testing. Subsequently, for each group, 14 specimens were tested for failure, seven by bending and seven in compression. No significant failure differences were observed between Groups 1 and 2 under static-loading or fatigue test. In a fracture gap model the orientation of the locked monocortical screws did not show any influence on the mechanical performance of the S.P.S. Free-Block
56

Influência do comprimento do parafuso nas propriedades biomecânicas da placa de reconstrução bloqueada / Influence of screw length on the biomechanical properties of locking reconstruction plate

Santos, Rogerio Rodrigues [UNESP] 08 May 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-05-08. Added 1 bitstream(s) on 2016-06-07T17:16:50Z : No. of bitstreams: 1 000857922_20170508.pdf: 29326 bytes, checksum: 99760ff26198070d08ca720e67a237dc (MD5) Bitstreams deleted on 2017-05-12T12:18:30Z: 000857922_20170508.pdf,. Added 1 bitstream(s) on 2017-05-12T12:19:16Z : No. of bitstreams: 1 000857922.pdf: 1490300 bytes, checksum: a56c5c6e846ff6eb08062cc79afba2a3 (MD5) / O trabalho teve por objetivo avaliar a influência do comprimento do parafuso, ou seja, uni ou bicortical, na resistência da montagem de uma placa de reconstrução bloqueada. Foram utilizados 60 corpos de prova cilíndricos de poliuretano e 60 placas de aço inoxidável de reconstrução de 3,5 mm, compostas de 7 furos. Cada corpo de prova foi dividido em duas porções iguais para simular uma falha segmentar de 10 mm. As placas foram montadas em dois grupos de construções: Grupo 1 - três parafusos unicorticais bloqueados em cada lado; Grupo 2 - três parafusos bicorticais bloqueados em cada lado. Em ambos os Grupos, na área da falha segmentar o orifício foi mantido sem parafuso. Para cada grupo, nove montagens foram testadas por ensaios estáticos até a falência, três em compressão, três em flexão e três em torção, para determinar as cargas de teste. Para os ensaios de fadiga, em cada grupo, 21 montagens foram testadas até a falência, sete em compressão, sete em flexão e sete em torção. Pela análise estatística, foram detectadas diferenças entre Grupos no ensaio de fadiga em compressão axial (G1>G2) e no ensaio de fadiga em flexão em quatro pontos (G1<G2), para carga máxima, carga mínima, momento máximo e momento mínimo. Não ocorreram diferenças entre grupos no ensaio de torção em fadiga. Foi possível concluir que o comprimento do parafuso pode afetar as propriedades mecânicas da placa de reconstrução bloqueada / The aim of this study was to evaluate the influence of screw length, mono or bicortical, on the mechanical properties of a locking reconstruction plate. Sixty cylinders of synthetic bone and 60 seven-hole 3.5 mm locking reconstruction plates were used. Each cylinder of synthetic bone was equally divided to simulate a gap fracture of 10 mm. Two groups of bone-plate constructs were mounted: Group 1 - three monocortical screws in each fracture side, Group 2 - three bicortical screws in each fracture side. In both groups, the area of the fracture gap was maintained without screw. To establish the loads for fatigue testing, for each group nine bone-plate constructs were tested until failure, each three in compression, bending, and torsion. For each group, 21 bone-plate constructs were tested for failure in fatigue testing, each seven in compression, bending, and torsion. By statistical analysis, significant differences between groups were observed for axial compression fatigue testing (G1>G2) and fourpoint bending fatigue testing (G1<G2) and in maximum load, minimum load, maximum moment, and minimum moment. No significant differences were observed between groups for torsion fatigue testing. In conclusion, the screw length can affect the mechanical properties of locking reconstruction plate
57

Influência do comprimento do parafuso nas propriedades biomecânicas da placa de reconstrução bloqueada /

Santos, Rogerio Rodrigues. January 2015 (has links)
Orientador: Sheila Canevese Rahal / Banca: Carlos Roberto Teixeira / Banca: César Renato Foschini / Banca: Alessandra Melchert / Banca: Elisangela Perez de Freitas / Resumo: O trabalho teve por objetivo avaliar a influência do comprimento do parafuso, ou seja, uni ou bicortical, na resistência da montagem de uma placa de reconstrução bloqueada. Foram utilizados 60 corpos de prova cilíndricos de poliuretano e 60 placas de aço inoxidável de reconstrução de 3,5 mm, compostas de 7 furos. Cada corpo de prova foi dividido em duas porções iguais para simular uma falha segmentar de 10 mm. As placas foram montadas em dois grupos de construções: Grupo 1 - três parafusos unicorticais bloqueados em cada lado; Grupo 2 - três parafusos bicorticais bloqueados em cada lado. Em ambos os Grupos, na área da falha segmentar o orifício foi mantido sem parafuso. Para cada grupo, nove montagens foram testadas por ensaios estáticos até a falência, três em compressão, três em flexão e três em torção, para determinar as cargas de teste. Para os ensaios de fadiga, em cada grupo, 21 montagens foram testadas até a falência, sete em compressão, sete em flexão e sete em torção. Pela análise estatística, foram detectadas diferenças entre Grupos no ensaio de fadiga em compressão axial (G1>G2) e no ensaio de fadiga em flexão em quatro pontos (G1<G2), para carga máxima, carga mínima, momento máximo e momento mínimo. Não ocorreram diferenças entre grupos no ensaio de torção em fadiga. Foi possível concluir que o comprimento do parafuso pode afetar as propriedades mecânicas da placa de reconstrução bloqueada / Abstract: The aim of this study was to evaluate the influence of screw length, mono or bicortical, on the mechanical properties of a locking reconstruction plate. Sixty cylinders of synthetic bone and 60 seven-hole 3.5 mm locking reconstruction plates were used. Each cylinder of synthetic bone was equally divided to simulate a gap fracture of 10 mm. Two groups of bone-plate constructs were mounted: Group 1 - three monocortical screws in each fracture side, Group 2 - three bicortical screws in each fracture side. In both groups, the area of the fracture gap was maintained without screw. To establish the loads for fatigue testing, for each group nine bone-plate constructs were tested until failure, each three in compression, bending, and torsion. For each group, 21 bone-plate constructs were tested for failure in fatigue testing, each seven in compression, bending, and torsion. By statistical analysis, significant differences between groups were observed for axial compression fatigue testing (G1>G2) and fourpoint bending fatigue testing (G1<G2) and in maximum load, minimum load, maximum moment, and minimum moment. No significant differences were observed between groups for torsion fatigue testing. In conclusion, the screw length can affect the mechanical properties of locking reconstruction plate / Doutor
58

Placas em ponte para tratamento de falhas segmentadas em mandíbulas de cães : projetos e desenvolvimento /

Freitas, Elisângela Perez de. January 2012 (has links)
Orientador: Sheila Canavese Rahal / Coorientador: Alexandre O. El Warrak / Banca: Carlos Roberto Teixeira / Banca: Maria Jaqueline Mamprim / Banca: Antonio Carlos Shimano / Banca: Silvio Eduardo Duailibi / Resumo: O trabalho teve por objetivos desenvolver placa em ponte bloqueada para a reconstrução de defeito ósseo segmentar em mandíbula de cães e validar o projeto por meio de análise pelo método de elementos finitos e ensaios biomecânicos. Inicialmente realizou-se a tomografia computadorizada da cabeça de quatro cães das raças Rottweiler, Doberman, Boxer e Poodle. Os dados obtidos em DICOM foram convertidos em objeto tridimensional pelo software Mimics 13.1 e usados na confecção do projeto das placas. Foram confeccionados, para cada raça, seis protótipos de mandíbula com defeito ósseo de tamanho de 1,5 vezes o diâmetro do corpo mandibular direito na área do primeiro pré-molar. A reconstrução mandibular foi feita com placa em ponte de titânio puro e parafusos (Ti 6Al 4V) monocorticais bloqueados, sendo um modelo para os cães de porte grande (Rottweiler e Doberman) e médio (Boxer) e outro para os de porte pequeno (Poodle). Os ensaios biomecânicos mostraram que o sistema placa-mandíbula resistiu além das forças de mastigação para todos os portes de cães e validaram os projetos das placas. O método de elementos finitos mostrou que o fator de segurança foi superior a 2. Foi possível concluir que as placas em ponte projetadas com geometria diferenciada e parafusos bloqueados monocorticais apresentam resistência mecânica suficiente para suportar os defeitos ósseos induzidos e são capazes de suportar pelo menos 5 vezes o valor da força de mordida para cada porte de cão estudado / Abstract: The aim of this study was to develop locked bridging plate to be used in segmental mandible defect in dogs, and to validate the project by finite element modeling (FEM) and mechanical testing. Computed tomography (CT) of the head of four dogs from Rottweiler, Doberman, Boxer and Poodle breeds were performed. The images were reconstructed in 3D format with specialized software (Mimics 13.1) and used to develop the plate project. For each breed dog, six mandible prototypes with a bone defect of 1.5 times the diameter of the right mandibular body at the first molar area were made. The mandibular reconstruction was performed with bridging plate in pure titanium and locked monocortical screws, being one design to large (Rottweiler e Doberman) and medium (Boxer) breed dogs, and another to small breed dog (Poodle). The mechanical testing showed that plate-mandible system resisted biting forces for all dogs and it validated the plate designs. FEM showed the security factor was higher than 2. In conclusion, the bridging plates designed with differentiated geometry and monocortical loc ked screws showed mechanical resistance to support the induced bone defects and were able to support at least 5 times the value of the bite force for each evaluated dog / Doutor
59

O efeito da orientação do parafuso bloqueado nas propriedades biomecânicas da placa S.P.S. Free-Block em corpos de prova nao osteoporóticos /

Agurto Merino, Marisol Karin. January 2011 (has links)
Orientador: Sheila Canevese Rahal / Banca: Alfredo Feio da Maia Lima / Banca: Celso Ribeiro / Resumo: Entre os modelos de fixadores internos há um sistema denominado S.P.S. Free-Block, cuja placa possui um anel trava que possibilita o bloqueio do parafuso em angulações variadas. Visto os poucos estudos biomecânicos com o sistema, o presente trabalho avaliou a influência da orientação do parafuso bloqueado na resistência da montagem. Foram usados cilíndricos sintéticos, nos quais foram promovidas falhas segmentares de 10 mm. As placas de aço com 7 furos (2 DCP e 5 bloqueados) foram montadas de acordo com a posição dos parafusos nos orifícios bloqueados: Grupo 1 - parafusos monocorticais posicionados em 90º, Grupo 2 - parafusos monocorticais posicionados de forma inclinada em 20º. Os parafusos dos orifícios DCP foram aplicados rotineiramente em posição neutra e de maneira bicortical. Na região da falha segmentar o orifício do parafuso bloqueado situado no centro da placa entre os DCP foi mantido livre. Em cada grupo, seis montagens foram testadas até a falência, três em flexão em quatro pontos e três em compressão axial, para determinar as cargas de teste. Posteriormente, em cada grupo, 14 montagens foram testadas até a falência em fadiga, sete em flexão e sete em compressão. Pela análise estatística não houve diferença na rigidez das construções entre os Grupos 1 e 2, tanto nos testes estáticos como nos de fadiga. Conclui-se assim que, em modelo de falha segmentar, o posicionamento do parafuso monocortical bloqueado não influenciou a resistência mecânica das montagens / Abstract: Among the locked internal fixators is one denominated S.P.S. Free-Block that was designed with a locking ring that allows the screw to be locked and positioned obliquely. Due to the paucity of biomechanical studies on this system, the present work aimed to evaluate the influence of locked screw orientation on the resistance of the S.P.S. Free-Block plate. Non-osteoporotic synthetic bone cylinders with 10 mm fracture gap were used. Seven-hole 3.5 mm stainless steel plates (two DCP holes and five locked holes) were assembled according to the orientation of the blocked screws: monocortical screws positioned at 90º to the long axis of the cylinder (G1), and monocortical screws positioned at 20º to its cylinder long axis (G2). In both groups, DCP hole screws were positioned bicortically and neutrally. In the region of the fracture gap, the locked screw hole at the plate's center was unfilled. For each group, six specimens were tested until failure, three in bending and three in compression, to determine the loads for fatigue testing. Subsequently, for each group, 14 specimens were tested for failure, seven by bending and seven in compression. No significant failure differences were observed between Groups 1 and 2 under static-loading or fatigue test. In a fracture gap model the orientation of the locked monocortical screws did not show any influence on the mechanical performance of the S.P.S. Free-Block / Mestre
60

Un nuevo copolímero para la regeneración tisular : estudio biomecánico y densitométrico

Lax Pérez, Raquel 22 January 2016 (has links)
Introducción: La pérdida de tejido óseo como consecuencia de infecciones, tumores, traumatismos, defectos congénitos o pseudoartrosis, representa un problema aún no resuelto en la cirugía ortopédica y traumatología. Las complicaciones asociadas a la utilización de los injertos óseos ,cifradas entre el 6 y 20 % en autoinjertos, así como los potenciales riesgos de carácter infeccioso e inmunológico relacionados con los aloinjertos, hacen que actualmente exista gran interés en buscar alternativas a éstos, en las matrices de soporte y los biomateriales. Hipótesis: “Determinar si el copolímero implantado en defectos óseos de tamaño crítico en radio de conejo permite la regeneración ósea total con idénticas características biomecánicas, morfológicas y densitométricas a las del hueso sano”. Material y método: Estudiamos la regeneración ósea obtenida con un copolímero constituido por micro-hidroxiapatita (mHAp), ácido poli-L-láctico (PLLA) y nanotubos de carbono de pared simple (SWCNT), dopado con o sin proteína morfogenética tipo 2 (rhBMP-2). Se crea un defecto de tamaño crítico (15 mm) en el radio de 30 conejos, a los que se les aplica tratamientos diferentes que se valoran mediante ensayos biomecánicos de flexión a 4 puntos (perfil polar de rigidez a flexión, índice de rigidez) y de torsión (par torsor recuperado); estudios densitométrico y de la morfología del callo, a las 8 y 16 semanas. A las 8 semanas se utilizan tres tratamientos diferentes (autoinjerto; copolímero sin rhBMP-2 y copolímero con rhBMP-2) y a las 16 semanas, dos tratamientos (autoinjerto y copolímero con rhBMP-2). Resultados y Discusión: En el estudio morfológico del callo óseo formado (TAC), a las 8 semanas, observamos consolidación completa del grupo tratado con autoinjerto. Los grupos tratados con copolímero dopado con y sin rhBMP-2, forman puentes óseos sin conseguir la consolidación completa del defecto y sin la reabsorción del andamio. En los ensayos a flexión a 4 puntos, para el parámetro perfil polar de rigidez a flexión (PPRF), sólo el autoinjerto a las 16 semanas, consigue una gráfica superponible al hueso sano En el parámetro índice de rigidez (SI), a las 8 semanas, encontramos diferencias significativas entre los grupos autoinjerto y copolímero dopado y entre los grupos copolímero dopado y sin dopar. A las 16 semanas, encontramos diferencias significativas entre los grupos autoinjerto y copolímero dopado. Los resultados de los ensayos a torsión, a las 8 semanas, para el par torsor recuperado (PTR) fueron 109,4% (autoinjerto); 85,5% (copolímero dopado) y del 71% (copolímero sin dopar). A las 16 semanas se obtienen valores de PTR superiores al hueso sano para los dos tipos de tratamiento. En los estudios densitométricos,a las 8 semanas, el copolímero con y sin rhBMP-2 consigue valores densitométricos, tanto del porcentaje de volumen (PV) como del porcentaje de densidad (PD) superiores al hueso sano. Las caracteristicas del hueso regenerado con nuestro copolímero son superiores biomecánica y desitométricamente, a las obtenidas por otros autores, en el tratamiento de defectos de tamaño crítico. Conclusiones: 1. La propiedades biomecánicas del hueso regenerado a partir del copolímero dopado como sin dopar con rhBMP-2, son comparables a las del hueso sano contralateral. 2. Las características densitométricas del hueso regenerado por el copolímero, tanto dopado como sin dopar con rhBMP-2, son semejantes en el estadío precoz del estudio, al hueso sano contralateral. 3. El copolímero “per se” regenera hueso siendo capaz de reparar defectos óseos de tamaño crítico. 4. El autoinjerto sigue considerándose mecánica y densitométricamente como la mejor opción de tratamiento en defectos óseos de tamaño crítico. No obstante, nuestro biomaterial analizado constituye una adecuada alternativa terapéutica. / Introduction: Bone tissue loss as a result of infections, tumours, traumas, hereditary defects or pseudoarthrosis represent a problem represents a problem which has not been solved yet in the field of orthopaedic surgery or traumatology. Difficulties associated to the use of bone grafts, up to 6 and 20% for autografts, as well as for those with a high infection- and immunological-type risk linked to allografts, arouses a special interest to search for alternatives to bone grafts in the support matrixes and biomaterials. Hypothesis: “To determine whether the copolymer implanted in critical-size bone defects in a rabbit radium permits a total bone regeneration with identical biomechanical, morphological and densitometric features as those of a healthy bone”. Materials and method: Bone regenaration resulting from a copolymer made of hydroxyapatite (mHAp), poli-L-lactic acid (PLLA) and single-wall carbon nanotubes (SWCNT), doped with or without morpho-genetic protein type 2 (rhBMP-2) is studied. A critical-size defect (15 mm) is created in the radium of 30 rabbits (white rabbits with a genetic line from New Zealand), which are applied different treatments which are judged by biomechanical tests (4-point flexion test and torsion), densitometric tests and callus morphology, during the 8th and 16th week. At the 8th week, three different treatments are used (autograft; copolymer without rhBMP-2 and copolymer with rhMBP-2) and at the 16th week, two treatments (autograft and copolymer with rhBMP-2). Results and discussion: In the bone-callus morphological research (TAC), at the 8th week a complete consolidation is observed by means of a micro-TAC in the group treated with autograft. Those groups treated with a copolymer with and without rhBMP-2 show bone bonding, but it does not reach a complete consolidation of the defect or a scaffold reabsorption. The results in the 4-point flexion, for the polar profile parameter of flexion stiffness (PPRF) the only group achieving a comparable graphic to a healthy bone, is the autograft tested at the 16th week. In the index-stiffness parameter (SI) at the 8th week statistically significant differences can be observed between the groups treated with an autograft and with a copolymer, whether doped or not. At the 16th week, significant differences can be found between the groups with autograft and doped copolymer. The results of the torsion essays, at the 8th week, for the recovery parameter of the torsion pair (PTR) were 109.4% (autograft), 85.5% (doped copolymer) and 71% (not doped copolymer). At the 16th week PTR values are higher than those of the healthy bon or both kinds of treatment. Densitomtrical researches results, at the 8th week, the copolymer with and without rhBMP-2 achieves higher densitometrical values than the healthy bone, as regards volume percentage (VP) and density percentage (DP). The features of the bone regenerated by our copolymer are biomechanically and densitometrically higher than those obtained by other authors when treating critical-size defects. Conclusions: 1. Biomechanical features of the bone regenerated y the copolymer, both doped or not doped with rhBMP-2 are comparable to the ones of the contralateral healthy bone. 2. The densitometric features of the bone regenerated by the copolymer, both doped and not doped with rhBMP-2, are similar to the contralateral healthy bone at the moment prior to this research. 3. The copolymer itself regenerates the bone, being able to repair critical-size bone defects. 4. Autograft is both mechanically and desitometrically the best option to repair critical-size defects. However, the biomaterials herein analysed constitutes an adequate therapeutic alternative.

Page generated in 0.0923 seconds