• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 224
  • 12
  • 12
  • 12
  • 12
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 234
  • 140
  • 139
  • 122
  • 100
  • 97
  • 52
  • 48
  • 36
  • 34
  • 28
  • 28
  • 27
  • 27
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estudo da osseointegração de implantes de liga Ti30Ta instalados sem estabilidade primária. Influência da associação adesivo fibrínico/ácido tranexâmico e da superfície bioativa / Osseointegration of study Ti30Ta alloy implants installed without primary stability. Association Influence adhesive fibrin / tranexamic acid and bioactive surface

Wada, Cristiane Mayumi [UNESP] 29 August 2016 (has links)
Submitted by CRISTIANE MAYUMI WADA null (cris_may_25@hotmail.com) on 2016-10-11T13:20:29Z No. of bitstreams: 1 dissertaçãofinalcristianemayumiwada.pdf: 5567228 bytes, checksum: f6d2788d12e34443b7620f7442328e1c (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-10-14T14:17:55Z (GMT) No. of bitstreams: 1 wada_cm_me_bauru.pdf: 5567228 bytes, checksum: f6d2788d12e34443b7620f7442328e1c (MD5) / Made available in DSpace on 2016-10-14T14:17:55Z (GMT). No. of bitstreams: 1 wada_cm_me_bauru.pdf: 5567228 bytes, checksum: f6d2788d12e34443b7620f7442328e1c (MD5) Previous issue date: 2016-08-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Quando implantes de titânio são instalados imediatamente após a extração dentária podem ocorrer ancoragem primária diminuída e retardo e/ou deficiência do processo de osseointegração. Isto se dá em razão da ampla interface entre as paredes circundantes do alvéolo e a superfície do implante. Evidências científicas demonstram que a resposta dos biomateriais quando inseridos num organismo vivo não depende apenas da sua composição, mas, sobretudo de sua superfície. Particularmente para os implantes dentários, o uso de ligas, o processo de usinagem e os tratamentos superficiais irão determinar características essenciais no desempenho clínico desses dispositivos. A liga Ti30Ta é altamente biocompatível, apresenta boa combinação de elevada resistência e baixo módulo de elasticidade, demonstrando excelente indicação para uso biomédico. O propósito deste trabalho foi avaliar histomorfometricamente em ratos o reparo ósseo ao redor de implantes de liga Ti30Ta com supertfície bioativa (tratamento hidrotérmico/biomimético) e associados à adesivo fibrínico/ácido tranexâmico. Foram confeccionados 32 implantes de Titânio CP Grau 4 (Grupo A/Ticp) e 32 implantes da liga Ti30Ta (Grupo B/Ti30Ta), os quais foram divididos em grupos com 8 implantes cada: GA1(Ticp), GA2(Ticp/ácido fibrínico/ácido tranexâmico), GA3(Ticp/superfície bioativa), GA4(Ticp/ Superfície Bioativa/Adesivo Fibrínico Ácido Tranexâmico), GB1(Ti30Ta), GB2 (Ti30Ta/ ácido fibrínico/ácido tranexâmico), GB3 (Ti30Ta/ superfície bioativa) e GB4(Ti30Ta/ Superfície Bioativa/Adesivo Fibrínico Ácido Tranexâmico). Os implantes dos Grupos A e B foram identificados, acondicionados individualmente, esterilizados por meio de radiação gama e implantados na tíbia direita de 64 ratos machos, os quais foram eutanasiados aos 60 dias pós-operatórios. As peças foram processadas em MMA (Stevenel’s blue/Alizarin red S) para análise histomorfométrica. Os resultados obtidos mostraram diferenças estatísticas significativas tanto para o percentual de contato osso/implante como para o percentual de área óssea dentro dos limites das roscas entre os grupos, com resultados superiores para liga Ti30Ta e para os grupos que receberam o tratamento bioativo de superfície associado à adesivo fibrínico/ácido tranexâmico tendo um percentual de 96,3%. Concluiu-se que a osseointegração de implantes de liga Ti30Ta instalados sem estabilidade primária foi favorecida pela associação adesivo fibrínico/ácido tranexâmico e superfície bioativa. Comparando-se a superfície de titânio com a superfície de Ti30Ta é possível observar um maior crescimento de apatita no Ti30Ta. A formação de uma camada de óxido de Ta2O5 no Ti30Ta pode ser hidratada em SBF para formar grupos de Ta-OH. Esses grupos induzem a nucleação da apatita e crescem espontaneamente consumindo íons de fosfato e cálcio do SBF. / When implants are installed immediately after tooth extraction it may occur decreased primary anchor and delay and / or deficiency of osseointegration process. This occurs because of the large interface between the surrounding walls of the socket and the surface of the implant. Scientific evidence shows that the response of biomaterials when inserted into a living organism depends not only on its composition, but mainly its surface. Particularly for dental implants, use of alloys, the process of machining and surface treatments will determine the essential clinical performance characteristics of these devices. The Ti-30Ta alloy is highly biocompatible and exhibits good combination of high strength and low modulus of elasticity, demonstrating excellent indication for biomedical use. The purpose of this study was to evaluate histomorphometrically in rats bone healing around Ti-30Ta alloy implants with bioactive surface (hydrothermal / biomimetic treatment) and associated with fibrin glue / tranexamic acid. They were made 32 CP titanium implants Grade 4 (Group A / Ticp) and 32 implants of Ti-30Ta alloy (Group B / Ti-30Ta). These groups (n = 8) were divided into groups: GA1 (Ticp), GA2 (Ticp / fibrin glue / tranexamic acid), GA3 (Ticp / bioactive surface) and GA4 (Ticp / bioactive surface/ fibrin glue /tranexamic acid) and GB1 (Ti-30Ta), GB2 (Ti-30Ta / fibrin glue / tranexamic acid), GB3 (Ti-30Ta bioactive surface) and GB4 (Ti-30Ta /bioactive surface/fibrin glue/tranexamic acid). The implants of Groups A and B were identified, packed individually and sterilized by gamma irradiation and implanted in the right tibia of 64 male rats. The animals were euthanized at 60 days postoperatively. The pieces were processed in MMA (Stevenel's blue / red Alizarin S) for histomorphometric analysis. The results showed statistically significant differences to both the contact percentage of bone / implant to bone as percentage area within the confines of the threads between the groups. Thus, superior results were observed for Ti-30Ta alloy and the groups that received the bioactive surface treatment associated with fibrin glue / tranexamic acid. It was concluded that the osseointegration of Ti-30Ta alloy implants installed without primary stability was favored by fibrin adhesive association / tranexamic acid and bioactive surface. Titanium surface comparing with Ti30Ta surface can be seen further growth of apatite in Ti30Ta. The formation of an oxide Ta2O5 layer in Ti30Ta can be hydrated in SBF to form Ta-OH groups. These groups induce the nucleation of apatite and grow spontaneously consuming phosphate and calcium ions from the SBF. / CNPq: 130367/2015-0
82

Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas: análise de elemento finito não linear com modelo tridimensional

Geremia, Tomás January 2014 (has links)
Made available in DSpace on 2015-04-30T14:06:27Z (GMT). No. of bitstreams: 1 000467680-Texto+Completo-0.pdf: 13016515 bytes, checksum: e3ef505603c7d5be9a1581e535fd60e2 (MD5) Previous issue date: 2014 / The aim of this study was to evaluate the influence of the number of implants and the distal tilting of posterior implants (27 degrees) on the resulting tensions in periimplant bone, abutment screw and prosthetic screw of mandibular full-arch fixed implant supported prosthesis, using a nonlinear finite element analysis. Six virtual models were created, simulating a mandibular full-arch prosthesis with a metallic framework: models with five parallel implants (5R) and with tilted posterior implants (5I); models with four parallel implants (4R) and tilted posterior ones (4I); and models with three parallel implants (3R) and with tilted posterior implants (3I). The Von Mises tensions were analyzed, on a qualitative aspect, on the three regions of interest. The results showed that tilting the posterior implants resulted in higher tensions on the periimplant bone region. Also, the implant placed adjacent to the loading area presented the higher stress magnitudes on the three regions of interest, during all the simulations. Within the limitations of this study, it's possible to conclude that tilting the posterior implants without distalizing the implants platforms, can represent higher Von Mises tensions on the cortical periimplant bone. Still, that the use of three implants supporting a mandibular full-arch prosthesis generated higher stress values on the analyzed regions, when compared to the models simulating four and five implants. / O objetivo do presente trabalho foi avaliar em reabilitações totais fixas implantossuportadas, através de uma Metodologia de Elementos Finitos não linear, a influência do número e da inclinação dos implantes posteriores em 27 graus para distal nas tensões em osso periimplantar cortical, parafuso do pilar protético e parafuso protético. Seis modelos virtuais foram gerados simulando uma prótese total fixa mandibular, com infraestrutura metálica: modelos com 5 implantes, paralelos entre si (5R) e com dois posteriores inclinados (5I); modelos com 4 implantes, paralelos entre si (4R) e com dois posteriores inclinados (4I); modelos com 3 implantes, paralelos entre si (3R) e com dois posteriores inclinados (3I). Uma força de 100 N foi simulada em região de primeiro molar, no cantilever protético. As tensões Von Mises resultantes foram analisadas de forma qualitativa nas três regiões de interesse. Os resultados mostraram que a utilização de implantes posteriores inclinados resultaram em maiores tensões na região periimplantar. Ainda, que o implante adjacente à carga apresentou os maiores valores de tensão nas três regiões avaliadas em todas as simulações. Dentro das limitações deste trabalho, pode-se concluir que a inclinação de implantes posteriores, sem a distalização das plataformas dos mesmos, mostra-se desfavorável no que diz respeito à incidência de tensões no osso periimplantar cortical. Além disso, a utilização de três implantes suportando uma prótese total fixa mandibular, apresentou maiores valores de tensão se comparado as situações com quatro e cinco implantes.
83

Avaliação histológica do contato osso-implante e estabilidade de implantes com superfícies modificadas: estudo experimental em tíbias de coelhos / Effect Of Implant Surface Properties On Osseointegration, Bone-To-Implant Contact And Stability Of Modified Sand-Blasted Acid-Etched Implants: An Experimental Study In Rabbits

Nunes, Leandro Soeiro de Souza January 2014 (has links)
Made available in DSpace on 2015-05-22T12:38:48Z (GMT). No. of bitstreams: 1 000468625-Texto+Completo-0.pdf: 2863238 bytes, checksum: 3e057c78a6b6e5cfbd0cf6767d59dd26 (MD5) Previous issue date: 2014 / The clinical success of the implant treatment is strongly related with the achievement and maintenance of the stability of the fixture. As the surface topography, roughness and wettability are modifications that can affect the quality of the osseointegration, several studies have analyzed the benefits of these modifications. The histomorphometric analyses of the bone-to-implant contact (BIC) and the resonance frequency analyses (RFA) are commonly used to verify the osseointegration and implant stability.In the present study, 32 implants with two different surfaces treatment were installed in the tibia of 16 New Zealand rabbits and splitted in two groups. The Group I was formed by Neodent Drive implants, with sandblasted, acid etched and hydrophilic surface (Neodent Drive Acqua, Neodent, Curitiba, Brasil). The Group II was formed by Neodent Drive implants, with sandblasted and acid etched surface (Neodent Drive Porous, Neodent, Curitiba, Brasil). The samples were analyzed at 07, 14, 30 and 60 days after the implant placement.The results showed statistically significant differences between the mean values for the BIC at 14 (p=0. 028) and 30 days (p=0. 028). The mean BIC for the Acqua implants (Group I) were 43,32 ± 1,31% and 55,03 ± 5,14%, at 14 and 30 days respectively. The mean BIC in the Porous implants (Group II) were 46,27 ± 0,10% and 47,13 ± 0,67%, at 14 and 30 days, respectively. At 60 days, the mean BIC for the Acqua implants were 54,68 ± 3,51% and for the Porous implants were 50,86 ± 1,03%.There were not statistically significant differences in the implant stability quotient (ISQ) measurements between Acqua and Porous implants, except at 07 days after the implant placement. At day 07, the results of the present study showed higher ISQ values for the Porous implants (68,75 ± 4,16%) than Acqua implants (61,5 ± 8,01%). The follow-up ISQ analyses in the same Group, showed statistically significant increases of the mean values from 7 to 60 days and from 30 to 60 days, for both groups.In conclusion, the sandblasted and acid etched treatment used to create roughness on the Neodent implant surface is reliable and allows bone apposition, as the BIC and ISQ values found were similar or superior than the showed in the literature for similar animal models and similar implant surface. The increase of the BIC and ISQ values on the follow up showed the achievement of the secondary stability and the increase in stiffness between the implant fixture and the surrounding tissues. There were not identified better results with the hydrophilic surface during the early period of healing. Thus, further investigations are necessary to confirm the suggested results in this present study. / A obtenção e a manutenção da estabilidade do implante são pré-requisitos para o sucesso clínico das próteses sobre implantes. Visto que a topografia, a rugosidade e a hidrofilicidade são algumas das alterações da superfície dos implante que podem alterar a resposta do tecido ósseo, diversos estudos tem procurado entender os benefícios que estas modificações podem proporcionar. A quantificação histomorfométrica do contato osso-implante (BIC) e a análise de frequência de ressonância (AFR) são parâmetros frequentemente utilizados na implantodontia para verificar a osseointegração e a estabilidade dos implantes.No presente estudo, foram instalados 32 implantes com duas diferentes superfícies nas tíbias de 16 coelhos, divididos em dois grupos: Grupo I) constituído pelos implantes com superfície tratada por jateamento de areia, ataque ácido, hidrofílica e modificada quimicamente (Neodent Drive Acqua, Neodent, Curitiba, Brasil) e Grupo II) constituído pelos implantes com superfície tratada por jateamento de areia e ataque ácido (Neodent Drive Porous, Neodent, Curitiba, Brasil). As amostras foram analisadas após 7, 14, 30 e 60 dias da colocação dos implantes.Na comparação da média geral do BIC, entre Acqua e Porous, foram observadas diferenças estatisticamente significantes no período de 14 dias (p=0,028) e no período de 30 dias (p=0,028). As medidas médias de BIC obtidas para os implantes Acqua foram 43,32 ± 1,31% e 55,03 ± 5,14%, aos 14 e 30 dias respectivamente. Para os implantes Porous, as medidas de BIC foram 46,27 ± 0,10% e 47,13 ± 0,67%, aos 14 e 30 dias respectivamente. No período de 60 dias, os valores médios de BIC da superfície Acqua foram 54,68 ± 3,51% e da superfície Porous foram 50,86 ± 1,03%.Na comparação da média geral do quociente de estabilidade do implante (QEI), entre Acqua e Porous, não foram observadas diferenças estatisticamente significantes entre os grupos, com exceção no período de 07 dias, no qual os resultados do presente estudo demonstraram maiores valores de QEI para o grupo Porous (68,75 ± 4,16%) do que para o grupo Acqua (61,5 ± 8,01%). A análise do QEI durante os diferentes períodos dentro de um mesmo grupo, demonstrou diferenças estatisticamente significativas entre os períodos de 7 vs 60 dias e 30 vs 60 dias, para a média geral do QEI no grupo Acqua e no grupo dos implantes Porous.As conclusões do presente estudo são que os resultados demonstraram que a modificação da superfície por jateamento de areia e ataque ácido utilizada para produzir as superfícies Acqua e Porous resulta em uma adequada aposição óssea, visto que os valores do BIC e QEI encontrados são similares ou superiores aos resultados encontrados na literatura com modelos experimentais e superfícies similares. Os aumentos dos valores do BIC e QEI durante os períodos pós-operatórios revelaram a obtenção de estabilidade secundária e maior rigidez na ancoragem do implante com o passar do tempo. Não foram identificados melhores resultados com a superfície hidrofílica nos períodos iniciais da osseointegração. Sendo assim, são necessários estudos pré-clínicos e clínicos para confirmar as sugestões que os resultados deste presente estudo revelaram.
84

Efeitos da radioterapia no processo de neoformação óssea na interface osso/implante e na expressão de citocinas IL-6 e TGF-ß: estudo in vivo / Effects of radiotherapy on the process of bone neoformation at the bone/implant interface and on the expression of IL-6 and TGFf-ß cytokines: in vivo study

Costa, Bruno César Almeida 02 May 2018 (has links)
Submitted by BRUNO CÉSAR ALMEIDA COSTA (brunnocesaracosta@hotmail.com) on 2018-05-14T19:21:25Z No. of bitstreams: 1 Dissertação _ Bruno Costa _ Completa 14_05.pdf: 1611275 bytes, checksum: 5bb1aa80f51943c2d30ac036450829f3 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-05-14T19:42:43Z (GMT) No. of bitstreams: 1 costa_bca_me_sjc.pdf: 1611275 bytes, checksum: 5bb1aa80f51943c2d30ac036450829f3 (MD5) / Made available in DSpace on 2018-05-14T19:42:44Z (GMT). No. of bitstreams: 1 costa_bca_me_sjc.pdf: 1611275 bytes, checksum: 5bb1aa80f51943c2d30ac036450829f3 (MD5) Previous issue date: 2018-05-02 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / No tecido ósseo, as injúrias decorrentes da radioterapia variam desde osteopenia até osteoradionecrose e devido a estas alterações, pacientes irradiados portadores de implantes vêm demonstrando maior taxa de insucesso. O objetivo neste estudo foi avaliar os efeitos da radioterapia, simulando uma dose total de um tratamento radioterápico convencional para pacientes oncológicos, na neoformação óssea ao redor de implantes instalados em fêmures de ratos, assim como na expressão de citocinas IL-6 e TGF-ß. Foram utilizados neste estudo 36 ratos que receberam implantes rosqueados de titânio grau V nos fêmures esquerdos. Os animais foram divididos em 3 grupos: a) Grupo controle (C): cirurgia de colocação dos implantes (tecido sadio sem irradiação); b) Grupo irradiação (I): irradiação e após 4 semanas cirurgia de colocação dos implantes c) Grupo irradiação imediata (IP): cirurgia de colocação dos implantes e depois de 24 horas irradiação. A irradiação foi realizada em duas etapas com doses de 15 Gy, totalizando ao final da segunda dose 30 Gy. Os animais foram eutanasiados nos períodos de 3 dias, 2 e 7 semanas após o tratamento. No momento da eutanásia, 0,5 ml de sangue foi coletado e os níveis séricos de IL-6 e TGF-β foram mensurados pelo método imunoenzimático (ELISA). Em cada período 04 animais foram submetidos à microtomografia computadorizada (µCT), visando avaliar a neoformação óssea na interface osso-implante. Os valores obtidos foram submetidos ao teste ANOVA um fator para análise estatística e quando necessário foi aplicado o teste de comparação múltipla de Tukey (p<0,05). Nos resultados obtidos por meio da análise de microtomografia em geral não foi observada diferença estatística entre os grupos (p>0,05). Contudo, no parâmetro volume ósseo observou-se no período de 2 semanas, diferença estatística (p<0,05) entre os grupos C e IP e o parâmetro separação de trabéculas mostrou no período de 2 e 7 semanas, diferença estatística (p<0,05) entre os grupos C e IP e Na avaliação de IL-6 o grupo C exibiu o maior valor e foi observada diferença estatisticamente significante (p<0,05) entre ele e os demais grupos em todos os períodos. Na avaliação de TGF-β foi observada diferença estatisticamente significante (p<0,05) entre o grupo I em comparação com os outros grupos nos períodos de 3 dias e 2 semanas, sendo o grupo I aquele que apresentou maior expressão. Concluiu-se que o osso irradiado recupera-se da irradiação com o decorrer do tempo, porém quando a irradiação ocorre imediata a cirurgia do implante o tecido ósseo exibe alterações mais significativas. / In bone tissue, the injuries resulting from radiotherapy vary from osteopenia to osteoradionecrosis and due to these alterations, irradiated patients with implants have been showing a higher rate of failure. The objective of this study was to evaluate the effects of radiotherapy, simulating a total dose of a conventional radiotherapy treatment for cancer patients, in the new bone formation around implants in rat femurs, as well as in the expression of IL-6 and TGF-β cytokines . Thirty-six rats receiving grade V titanium implants in the left femora were used in this study. The animals were divided into 3 groups: a) Control group (C): implant placement surgery (healthy tissue without irradiation); b) Group irradiation (I): irradiation and after 4 weeks implant placement surgery c) Immediate irradiation (IP) group: implant placement surgery and after 24 hours irradiation. Irradiation was performed in two steps with doses of 15 Gy, totaling at the end of the second dose 30 Gy. The animals were euthanized at 3 days, 2 and 7 weeks after treatment. At the time of euthanasia, 0.5 ml of blood was collected and serum levels of IL-6 and TGF-β were measured by the enzyme-linked immunosorbent assay (ELISA). In each period, 04 animals were submitted to computerized microtomography (μCT), aiming to evaluate the bone neoformation at the bone-implant interface. The obtained values were submitted to ANOVA a factor for statistical analysis and when necessary the Tukey multiple comparison test (p <0.05) was applied. In the results obtained through the microtomography analysis in general no statistical difference was observed between the groups (p> 0.05). However, the parameter separation of trabeculae showed, in the period of 2 and 7 weeks, statistical difference (p <0.05) between groups C and PI and in the bone volume parameter showed in the period of 2 weeks, statistical difference (p <0, 05) between groups C and IP. In the evaluation of IL-6, group C showed the highest value and a statistically significant difference (p <0.05) was observed between him and the other groups in all periods. In the evaluation of TGF-β, a statistically significant difference (p <0.05) was observed between group I in comparison with the other groups in the periods of 3 days and 2 weeks, with group I being the one with the highest expression. It was concluded that irradiated bone recovers from irradiation over time, but when irradiation occurs near implant surgery, the bone tissue exhibits more significant changes. / 2015/24986-8
85

Reconstrução imediata de diferentes defeitos peri-implantares em implantes pós-exodônticos : análise histomorfométrica em cães /

Pereira, Flávia Priscila. January 2013 (has links)
Orientador: Eduardo Hochuli Vieira / Co-orientador: Daniele Botticelli / Banca: Idelmo Rangel Garcia Junior / Banca: Wilson Roberto Poi / Banca: Michel Reis Messora / Banca: Cassio Edvard Sverzut / Resumo: Objetivo: A proposta deste estudo foi avaliar a regeneração óssea de defeitos criados cirurgicamente e naturais circunferenciais (gap) de implantes pósexodônticos. Materiais e método: Para este estudo foram utilizados 8 cães da raça labrador, nos quais foram instalados implantes imediatos (pós-exodônticos) nos alvéolos dos dentes P2 (2o pré-molar) e M1 (1o molar) inferiores bilaterais. Nos implantes da região dos 2º pré-molares bilaterais foram criados cirurgicamente defeitos peri-implantares vestibulares que foram preenchidos de um lado por osso autógeno - OA e do outro por osso bovino inorgânico Bio-Oss ®- OB. Nos alvéolos correspondentes aos primeiros molares (M1) os implantes foram instalados e os gaps (defeitos naturais) existente entre a tábua óssea vestibular e o implante, foram preenchidos por Bone Ceramic ® - (grupo BC) ou somente coágulo (grupo COA). Todos os sítios cirúrgicos foram posteriormente recobertos por membrana de colágeno reabsorvível (Biogide ®) e mantidos com cicatrizador. Após 4 meses de pós-operatório, os animais foram eutanasiados e os blocos ósseos processados laboratorialmente para análise histomorfométrica. Resultados: Os resultados obtidos nos implantes instalados na região do P2 mostraram que os valores do IS-C foram ligeiramente maior (2.3±0.8mm) no grupo OA, comparado ao grupo OB (1.7± 0.7 mm), enquanto o IS-B dos grupos OA e OB foram respectivamente de 2.7±0.7mm e 2.2±1.0 mm no lado vestibular e de 1.6±0.8mm e 0.8±0.5mm no lado lingual. As médias dos valores de PM-C, PM-B e PM-IS no grupo OA e OB foram respectivamente de 4.3±0.9mm, 4.7±0.9mm, 2.0±1.6mm e 4.3±0.6mm... / Abstract: Objective: The purpose of these studies were to evaluate bone regeneration at natural or surgically-created buccal defects at implants placed immediately into extraction sockets (IPIES). Material and methods: Eight Labrador dogswere used and implants were placed immediately into the extraction sockets of P2 (second premolar ) and M1 (first molar), bilaterally. At P2, the buccal wall of the extraction sockets was removed bilaterally to create a standardized defect, 4 mm wide coronally, 2 mm wide apically, and 6 mm height. At P2 sites, Bio-Oss at the test (OB) or autogenous bone at the control (OA) sites were used to fill the defects. At M1 sites, Bone Ceramic ® at the test (BC) or the clot alone (COA) were used to fill the defects. All surgical sites were subsequently covered by a resorbable collagen membraneand a non-submerged healing was allowed . After 4 months the animals were euthanized, bone blocks harvested and processed for histomorphometric analysis . Results: at P2 sites, IS- C values were slightly higher (2.3±0.8mm) in the OA compared to the OB (1.7±0.7 mm). IS- B were 2.7 ± 0.7mm and 2.2 ± 1.0mm on the buccal side and 1.6 ± 0.8mm and 0.8 ± 0.5mm on the lingual side at OA and OB groups, respectively. The average values of PM- C , B - PM and PM -IS in OA and OB groups were 4.3 ± 0.9mm , 4.7 ± 0.9mm , 2.0 ± 1.6mm and 4.3 ± 0.6mm , 4.8 ± 0.6mm , 2.5 ± 0.8mm, respectively. A statistically significant difference was only observed in the thickness of the buccal bony crest at 2-5 mm apically to IS (the implant neck) when the biomaterial (S -OCbt )... / Doutor
86

Estudo do comportamento biomecânico em protocolos modificados de Branemark (conceito All-on-Four) : análise por extensometria linear elétrica /

Castilho, Anderson Almeida. January 2012 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Alberto Noryuki Kojima / Banca: Estevão Tomomitsu Kimpara / Banca: Alfredo Mikail Melo Mesquita / Banca: Marco Antonio Melloncini / Resumo: O objetivo deste estudo foi analisar in vitro, por meio de extensometria linear elétrica, o comportamento biomecânico em protocolos de Brånemark em mandíbulas, modificados pelo conceito All-on-Four, para que seja possível se estabelecer uma correlação entre tensão, deformação e eventos biomecânicos que possam acontecer no tecido ósseo peri-implantar referente a mudança do eixo de instalação de implantes posicionados próximos às extensões em cantlever. Para tanto, foram confeccionados dez modelos experimentais (G1, n=5) e (G2, n=5) homogêneos à base de poliuretano nos quais foram instalados quatro implantes de conexão externa e quatro pilares tipo micro-unit em duas configurações para os implantes distais. Para o efeito configuração (Configuração) no G1, os implantes foram instalados de forma axial e paralelos entre si. Para o efeito configuração no G2, os dois implantes distais foram instalados em angulação de 300 - sentido distal. O monitoramento das deformações foi obtido em 3 níveis de profundidade (NP) (cervical, médio e profundo) para cada implante, assim como em dois pontos de aplicação de carregamento estático de 50N (PAC) (ponto A em cantlever e ponto B em ponto mediano). Foram coletadas três leituras de microdeformação (ε) para cada extensômetro. Os dados coletados foram submetidos aos testes estatísticos ANOVA e Tukey (α=5%). Para as condições experimentais, os grupos após ensaio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate in vitro, the biomechanical behavior in Brånemark protocols modified by the All-on-Four concept, by strain gauge analysis, to establish a correlation between stress, strain and biological events that may occur in the peri-implant bone tissue in two diferent distaly implants configuration. Ten polyurethane experimental models were fabricated (Group 1, n = 5) and (Group 2, n = 5) which were installed four external hex implants and four micro-unit abutments, in two diferent tilting set-up for the distal implants. For the configuration effect in G1, the implants were installed axially and parallel to each other. In G2 group, the two distal implants were tilted 30 degrees. The microstrain data were obtained in 3 deep levels (NP) (cervical, medium and deep) via two linear strain gauges bonded on the mesial and distal surface for each implant. A static load of 50 N was applied on two points (PAC) (A - cantlever point and B - median point). Three microstrain measurements (με) were performed for each strain gauge. Data were analyzed by ANOVA and Tukey's test for multiple comparisons at 5% level of significance. For the experimental conditions, the groups after testing showed mean ... (Complete abstract click electronic access below) / Doutor
87

Avaliação de substitutos ósseos em defeitos peri-implantares criados em coelhos /

Santos, Pâmela Letícia dos. January 2013 (has links)
Orientador: Idelmo Rangel Garcia Junior / Coorientador: Eloá Rodrigues Luvizuto / Banca: Ana Paula de Souza Faloni / Banca: Thallita Pereira Queiroz / Banca: Roberta Okamoto / Banca: Osvaldo Magro Filho / Resumo: Objetivo: Avaliar a efetividade dos substitutos ósseos, matriz de osso bovino mineralizada - (Bio-Oss®) e matriz de osso bovino mineralizada com adição de 10% de colágeno suíno - (Bio-Oss® Collagen), no preenchimento de defeitos peri-implantares criados em tíbia de coelhos, por meio das análises biomecânica, histológica e imunoistoquímica para a expressão das proteínas OC, Runx 2, OPG, RANK-L e TRAP . Material e Métodos: Trinta coelhos receberam 1 ostectomia em cada tíbia por meio de trefina de 6.1 mm de diâmetro. Em seguida, foram utilizadas as fresa lança e helicoidais no preparo de leitos receptores com 3,0mm e 1 implante de 4,1 mm/8,5 mm foi instalado. Os defeitos ósseos peri-implantares foram preenchidos de acordo com os seguintes grupos: I- coágulo sanguíneo (CO); II- Bio-Oss® (BI); e III- Bio-Oss® Collagen (BC). Dez animais por período foram eutanasiados aos 15, 30 e 60 dias pós-operatórios, para as análises biomecânica, histológica e imunoistoquímica. Resultados: Na análise biomecânica, pode-se observar que o grupo BC apresentou melhor resposta, estatisticamente significante, quando comparado ao CO, no período de 30 dias. Os resultados imunoistoquímicos mostraram na comparação entre os 3 grupos a expressão da OC foi diferente estatisticamente nos períodos de 15 e 60 dias entre os grupos CO e BC; e CO e BI, respectivamente, observando maior expressão para o grupo dos biomateriais aos 15 dias. A expressão de Runx2 foi menor estatisticamente para o grupo BI quando comparado aos demais grupos, no período de 15 dias. Aos 60 dias, a expressão de OPG no grupo BI se apresentou estatisticamente maior que o grupo CO. Nos períodos de 15 e 60 dias, pode-se observar maior expressão de RANK-L... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: To evaluate the effectiveness of bone substitutes in peri-implant defects created in tibia of rabbits which were filled either by blood clot, deproteinized bovine bone mineral (Bio-Oss® / Geistlich) and bovine bone mineral with the addition of 10% collagen porcine origin (Bio-Oss Collagen® / Geistlich), through biomechanics, histology and immunohistochemical analysis of OC, Runx 2, OPG, RANK-L and TRAP proteins. Material and methods: Thirty rabbits received one osteotomy in each tibia using trefine of 6.1 mm in diameter. Subsequently, a spear and helical drills, 2.0 mm, 2.0/3.0 pilot and 3.0 mm were used and 1 implant 4.1 mm/8.5 mm was installed. Bone defects were filled according to the following groups: I-blood clot (CO); II-deproteinized bovine bone mineral (Bio-Oss®) (BI); III-bovine bone mineral with addition of 10% collagen porcine origin (Bio-Oss Collagen®) (BC). Ten animals per period were euthanized at 15, 30 and 60 postoperative days, subsequently biomechanical analysis were performed. Routine histologic processing for histological and immunohistochemistry analysis were also performed. Results: In biomechanics analysis, comparing the different groups for each period can be observed that within 30 days, the BC group showed better biological response statistically proven compared to CO. In immunohistochemistry analysis, the OC expression was statistically significant at 15 and 60 days between CO and BC groups, and between CO and BI groups, respectively, with largest expression for the group of biomaterials. In these same analysed periods, an increased expression of RANK-L can be observed on BI group compared to CO group. OPG expression was statistically significant only iat 60 postoperative days for BI group... (Complete abstract click electronic access below) / Doutor
88

Utilização do extrato de óleo insaponificável de abacte e soja na osseointegração. Avaliação biomecânca, radiográfica, histológica e histomorfométrica em ratos /

Paula, Luiz Guilherme Freitas de. January 2012 (has links)
Orientador: Rosemary Adriana Chiérici Marcantonio / Banca: José Eduardo Cezar Sampaio / Banca: Ana Emilia Farias Pontes / Resumo: Este estudo avaliou a influência da utilização do extrato de óleo insaponificável de abacate e soja na osseointegração de implantes. Foram utilizados implantes de titânio com 4 mm de comprimento por 2.2 mm de espessura, instalados nas tíbias de ratos. Os 30 ratos foram divididos randomicamente em três grupos: 1- instalação de implantes e administração de soro fisiológico; 2- administração do extrato de óleo insaponificável de abacate e soja 7 dias antes dos implantes; 3- instalação dos implantes e administração do extrato de óleo insaponificável de abacate e soja. O medicamento foi administrado por gavagem diariamente, durante 60 dias até o sacrifício. A avaliação se deu através de exames radiográficos (por densidade óssea/milímetro de alumínio), realizados no dia da instalação dos implantes e no dia do sacrifício; análise biomecânica; análise histomorfométrica de contato osso-implante e preenchimento ósseo entre as roscas dos implantes (regiões medulares e corticais ósseas); e análise histológica. O teste de Shapiro-Wilk foi aplicado para a verificação da normalidade dos dados, e o teste paramétrico ANOVA complementado pelo teste de Tukey foi utilizado para comparação dos dados. Todos os testes foram aplicados com nível de significância de 95%. Os resultados obtidos da análise radiográfica nas imagens iniciais, o grupo II apresentou menores valores de densidade tanto nas regiões de osso cortical como medular comparados aos grupos I e III. Entretanto, as razões de densidade radiográfica do osso nas imagens finais foram sem diferença estatística para todos os grupos. Na análise biomecânica não houve diferenças estatísticas entre os grupos. Na histologia descritiva e histometria, o grupo I apresentou menor contato osso-implante na área da cortical óssea em relação aos demais grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:This study evaluated the influence of the use of oil extract of avocado and soybean unsaponifiables on osseointegration of implants. Titanium implants used were 4 mm long by 2.2 mm thick, installed in the rat tibia. The 30 rats were randomly divided into three groups: 1 - implant placement and administration of saline, 2 - Administration of the extract oil of avocado and soybean unsaponifiable 7 days before the implants, 3 - implant placement and administration of the extract oil Avocado and soybean unsaponifiables. The drug was administered by gavage daily for 60 days until sacrifice.The evaluation was made by radiographic examination (for bone density / mm of aluminum), performed on the day of implant placement and the day of sacrifice, biomechanical, histomorphometric analysis of bone-implant contact and bone fill between the threads of the implants ( medullary and cortical bone regions), and histological analysis. The Shapiro-Wilk test was applied to verify the normality of the data, and parametric test ANOVA complemented by Tukey's test was used to compare the data. All tests were applied with a significance level of 95%. The results of radiographic images in the initial group II had lower density in the regions of cortical bone marrow as compared to groups I and III. However, the reasons for radiographic density of bone in the final images were no statistically significant difference for all groups. In biomechanical analysis no statistical differences between groups. Histologically descriptive and histometric analysis, group I showed lower bone-implant contact in the area of cortical bone in relation to other groups. The extract oil unsaponifiable of avocado and soybean had a positive influence on osseointegration of implants / Mestre
89

Avaliação da influência de diferentes superfícies na adesão e proliferação de osteoblastos humanos

Guimarães, Magáli Beck January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:05Z (GMT). No. of bitstreams: 2 000422228-0.pdf: 2027786 bytes, checksum: fc45ed715786efb01f83f7fff755ceef (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Nowadays, the focus of many researches in Implant Dentistry is on the modification of the titanium surface in search of alternatives that can provide more quickness and quality to the osseointegration process. Osseointegration is a phenomenon that happens mainly through the interfacial response of bone cells in contact with the titanium surface. There are different treatment methods that can be used to modify the topographic and chemical properties of the titanium surface in order to optimize the tissue-implant reactions. In this study, we evaluated the influence of different titanium surface treatments in the adhesion and proliferation of human osteoblasts by quantitatively analyzing the number of adherent cells in different cell culture periods. Forty level II titanium disks with 15mm diameter and 1mm thickness were divided into four groups according to their surface characterization: G1. machined; G2. acid-etched; G3. with hydroxyapatite coating; and G4. with bisphosphonate immobilized on hydroxyapatite coating. Osteoblast cells derived from human osteosarcoma (SaOS-2) were cultured on the disks and the cell counting was made in 3, 7 and 14 days. To determine the number of cells, a coloring process of the nucleus using propide iodide was carried out and disks were then analyzed in an optical microscope under ultraviolet light. The cell counting in the different experimental groups and culture periods was compared using ANOVA complemented by Tukey’s test. Results of the statistical analysis made it possible to conclude that: (1) the titanium surface and the cell culture period, as well as the interaction of both, significantly affect the cell growth; (2) modifying the titanium surface by acid-etching favors the adhesion and proliferation of human osteoblasts, in vitro. Further researches are necessary to elucidate the immobilized bisphosphonate influence on the titanium surface at the initial osteogenesis events. / Atualmente, o foco de muitas pesquisas científicas em Implantodontia está voltado para a modificação da superfície do titânio na busca de alternativas que proporcionem maior rapidez e qualidade no processo de osseointegração. A osseointegração é um fenômeno que acontece fundamentalmente através da resposta interfacial das células ósseas em contato com a superfície do titânio. Diferentes métodos de tratamento podem ser utilizados para modificar as propriedades topográficas e químicas da superfície do titânio a fim de otimizar as reações tecido-implante. Neste estudo foi avaliada a influência de diferentes tratamentos de superfície do titânio na adesão e proliferação de osteoblastos humanos, através da análise quantitativa do número de células aderidas em diferentes períodos de cultura celular. Para isso, 40 discos de titânio grau II, comercialmente puro, de 15mm de diâmetro e 1mm de espessura, foram divididos em quatro grupos conforme a caracterização de sua superfície: G1. maquinada; G2. ácido-condicionada; G3. com cobertura de hidroxiapatita; e G4. com bisfosfonato imobilizado na cobertura de hidroxiapatita. Células osteoblásticas derivadas de osteossarcoma humano (SaOS-2) foram cultivadas sobre os discos e a contagem celular foi realizada em 3, 7 e 14 dias. Para determinação do número de células, um processo de coloração dos núcleos com Iodeto de Propídio foi realizado, e os discos foram analisados em microscópio óptico sob luz ultravioleta. As contagens celulares nos diferentes grupos experimentais e períodos de cultura foram comparadas por meio de ANOVA, complementado pelo teste de Tukey. Os resultados da análise estatística permitem concluir que: (1) a superfície do titânio e o período de cultura celular, bem como a interação de ambos, significativamente afetam o crescimento celular; (2) a modificação na superfície do titânio através de condicionamento ácido favorece, in vitro, a adesão e proliferação de osteoblastos humanos. Mais pesquisas são necessárias para elucidar a influência do bisfosfonato imobilizado na superfície do titânio nos eventos iniciais da osteogênese.
90

Análise comparativa do efeito de diferentes superfícies sobre a resposta tecidual perimplantar em regiões com baixa densidade óssea: modelo animal coelho

Post, Letícia Kirst January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:07Z (GMT). No. of bitstreams: 2 000417615-0.pdf: 921449 bytes, checksum: b1758518b6fea65cac8a47bf9564b908 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The possibilities of changing implant surface properties are numerous, both in terms of chemical and biological aspects and also of surface morphology and topography. Recent studies have focused on establishing an implant surface with characteristics that optimize osseointegration in sites with low bone density. The aim of the present study was to carry out clinical and histological assessments of the influence of different implant surfaces on the response of peri-implant tissues with low bone density. Eight male New Zealand rabbits were used in the study. The following implant surfaces were assessed: cast titanium (G1), acid-etched titanium (G2), titanium coated with titanium plasma spray (G3), and titanium coated with new acidetched porous titanium coating (G4).Animals were sacrificed 30 days after surgery. Following clinical assessment of implant stability in the alveolar bone, tibia bone fragments containing the implants were prepared and submitted to histological analysis. Clinical assessment results showed that all implants achieved stability in peri-implant tissues. In some specimens, new bone formation was observed, as well as tissue migration to the coronal, non-submerged area of the implant. Our findings suggest that the implant surface G3 was the one that most contributed to bone regeneration, with minimum foreign body reaction observed in peri-implant tissues. / As possibilidades de modificação das propriedades de superfície dos implantes são muito grandes, tanto com relação aos aspectos químico e biológico quanto aos morfológico e topográfico. Pesquisas recentes têm-se dedicado a buscar uma superfície que otimize o processo de osseointegração em regiões com baixa densidade óssea. Assim, o objetivo deste estudo foi avaliar a influência de diferentes superfícies implantares sobre a resposta tecidual em regiões com baixa densidade óssea. Foram utilizados para este estudo 8 coelhos machos da raça Nova Zelândia. Em cada animal foram inseridos, cirurgicamente, 4 implantes cilíndricos, sendo na tíbia direita as amostras dos grupos G1 (superfície usinada) e G2 (tratamento com ataque ácido de rotina) e na tíbia esquerda as amostras dos grupos G3 (superfície com camada porosa de titânio) e G4 (superfície com camada porosa de titânio mais tratamento com ataque ácido inovador) O experimento foi repetido, de forma idêntica, em todos os animais. Durante todo o período de observação (30 dias), os animais permaneceram saudáveis, com cicatrização normal na região operada, sem evidência de infecção ou deiscência de sutura. Todos os implantes obtiveram estabilidade ao tecido perimplantar, mesmo após o processo de descalcificação óssea. Em alguns grupos da amostra a neoformação óssea cobriu a porção coronal não submersa dos implantes. Os resultados da análise histológica evidenciaram que a interface óssea com os implantes dos grupos G1 e G2 foi caracteristicamente linear e regular e com G3 e G4 mais irregular. De modo geral, os implantes do grupo G3 melhor contribuíram para a dinâmica do reparo ósseo.

Page generated in 0.0415 seconds