• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 224
  • 12
  • 12
  • 12
  • 12
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 234
  • 140
  • 139
  • 122
  • 100
  • 97
  • 52
  • 48
  • 36
  • 34
  • 28
  • 28
  • 27
  • 27
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Capacidade osteorregenerativa da elastina, hidroxiapatita e proteí­na morfogenética óssea no tratamento de defeitos femorais em ratos / Osseoregenerative capacity of elastin, Hydroxyapatite and bone morphogenetic protein in the treatment of femoral defects in rats

Munhoz, Marcelo de Azevedo e Souza 23 March 2018 (has links)
Nas doenças que provocam perdas ósseas, destaca-se a utilização de enxerto ósseo autólogo como tratamento padrão-ouro. Entretanto, devido a comorbidades e limitação quantitativa, apresentam-se como alternativa o uso de biomateriais de elastina e hidroxiapatita, bem como a associação com a proteína morfogenética óssea. O objetivo desta pesquisa foi avaliar de forma qualitativa e quantitativa a contribuição da membrana de elastina utilizada isoladamente ou em combinação com a hidroxiapatita e a proteína morfogenética óssea no reparo de defeitos ósseos provocados experimentalmente no fêmur de ratos. Foram utilizados 77 ratos (Rattus norvegicus, Wistar), machos, com peso aproximado de 330 gramas e 4 meses de idade. Os animais foram submetidos ao procedimento cirúrgico para criação do defeito ósseo na superfície anterior da região supracondiliana do fêmur direito e separados em 7 grupos com 11 animais cada. Os grupos foram divididos da seguinte forma: Grupo controle (G1-C), ratos com defeito crítico induzido no osso femoral, sem preenchimento com implante. Grupo 2 (G2-E24/50), ratos com defeito crítico induzido no osso femoral preenchido com membrana de elastina hidrolisada durante 24h a 50°C; Grupo 3 (G3-E24/50/HA), defeito preenchido com membrana de elastina hidrolisada durante 24h a 50°C e hidroxiapatita. Grupo 4 (G4 E24/50/BMP), defeito preenchido com membrana de elastina hidrolisada durante 24h a 50°C e BMP. Grupo 5 (G5-E96/37), defeito preenchido com membrana de elastina hidrolisada durante 96 h a 37°C. Grupo 6 (G6-E96/37/HA), defeito preenchido com membrana de elastina hidrolisada durante 96 h a 37°C e hidroxiapatita. Grupo 7 (G7-E96/37/BMP), defeito preenchido com membrana de elastina hidrolisada durante 96 h a 37°C e BMP. Após a morte indolor induzida após 6 semanas, as peças anatômicas femorais foram retiradas para análise macroscópica, radiográfica, histológica, morfométrica e biomecânica. As médias e desvios-padrão do volume percentual relativo de osso neoformado no defeito femoral foram respectivamente 36,39±3,86 (G1); 66,40±3,69 (G2); 55,12±2,23 (G3); 58,46±1,79 (G4); 51,36±3,15 (G5); 71,28±4,26 (G6); 45,54±3,98 (G7). Os achados demonstraram biocompatibilidade, biodegradabilidade e osteorregeneração maior que o grupo controle nos biomateriais estudados. Os grupos com maior volume ósseo neoformado foram G2-E24/50 e G6-E96/37/HA. / In diseases that cause bone loss, the use of autologous bone graft is still a goldstandard treatment. However, due to comorbidities and quantitative limitation, the use of biomaterials of elastin, hydroxyapatite as well as the association with the bone morphogenetic protein are presented as alternatives. The objective of this research is to evaluate in a qualitative and quantitative way the contribution of the elastin membrane used alone or in combination with the hydroxyapatite and the bone morphogenetic protein in bone defects experimentally created in femur of rats. A total of 77 male rats (Rattus norvegicus, Wistar) weighing approximately 330 grams and 4 months of age were used. The animals were submitted to the surgical procedure to create the bone defect on the anterior surface of the supracondylar region of the right femur and were separated into 7 groups with 11 animals each. The groups were divided as follows: Control group (G1-C), rats with critical defect induced in the femoral bone without implant filling. Group 2 (G2-E24/50), defect filled with elastin membrane prepared for 24 h at 50°C. Group 3 (G3-E24/50/HA), defect filled with elastin membrane prepared for 24 h at 50°C and hydroxyapatite. Group 4 (G4-E24/50/BMP), defect filled with elastin membrane prepared for 24 h at 50°C and BMP. Group 5 (G5- E96/37), defect filled with elastin membrane prepared for 96 h at 37°C. Group 6 (G6- E96/37/HA), defect filled with elastin membrane prepared for 96 h at 37°C and hydroxyapatite. Group 7 (G7-E96/37/BMP) defect filled with elastin membrane prepared for 96 h at 37°C and BMP. After painless death induced after 6 weeks, the femoral anatomical pieces were removed for macroscopic, radiographic, histological, morphometric and biomechanical analysis. The mean and standard deviations of the relative percentage volume of newly formed bone in the femoral defect were respectively 36,39±3,86 (G1); 66,40±3,69 (G2); 55,12±2,23 (G3); 58,46±1,79 (G4); 51,36±3,15 (G5); 71,28±4,26 (G6); 45,54±3,98 (G7). The findings demonstrated biocompatibility, biodegradability and osseous regeneration greater than the control group in the studied biomaterials. The groups with the highest newly formed bone volume were G2-E24/50 and G6-E96/37/HA.
122

Influência de diferentes doses de PTH sintético (1-34) sobre a reparação de enxertos ósseos autógenos. Estudo em ratos / Influence of different doses of synthetic PTH (1-34) on autogenous bone graft healing. Study in rats

Santos, Rodrigo Albuquerque Basilio dos 15 June 2015 (has links)
O objetivo do presente estudo foi investigar o efeito do hormônio paratireoideano sintético (1-34) na reparação de enxertos ósseos autógenos, fixados próximo ao ângulo da mandi?bula de ratos. Adicionalmente, foi avaliado se doses mais baixas que as estudadas previamente (em outros modelos experimentais) ainda apresentam um efeito osteoanabólico, favorecendo a integração do enxerto ao leito. Para isto, realizou-se um estudo paralelo, cego onde foram utilizados 50 ratos Wistar machos adultos. Sob anestesia geral, uma trefina de diâmetro interno de 3,5 mm foi utilizada para a remoção do enxerto ósseo em bloco da calva?ria do animal. O enxerto foi fixado próximo ao ângulo da mandi?bula do rato, na cortical vestibular, através de um implante de titânio (1,4 mm de diâmetro e 2,5 mm de comprimento). Após o procedimento cirúrgico, os animais foram sorteados para receber um dos seguintes tratamentos: grupo 1: injeções do veículo necessário para a dissolução do hormônio (n=15); grupo 2: injeções subcutâneas de 2 ?g/kg de PTH sintético (1-34) três vezes por semana (n=15) e grupo 3: injeções subcutâneas de 40 ?g/kg de PTH sintético (1-34) três vezes por semana (n=15). Trinta dias após a cirurgia, os animais foram sacrificados, e as peças contendo o enxerto, o implante e o osso circundante removidas e processadas histologicamente para cortes não descalcificados. Os seguintes parâmetros histométricos foram avaliados nas regiões adjacentes ao implante: espessura total do conjunto leito+gap+enxerto (ET) e espessura do enxerto (EE). E os seguintes parâmetros foram avaliados dentro dos limites das roscas dos implantes: preenchimento ósseo (PR) e contato direto com a superfície do implante (CD). Cinco animais foram sacrificados imediatamente após o procedimento cirúrgico (tempo zero) fornecendo referências iniciais das dimensões do enxerto, gap e leito antes da reparação óssea. A análise histométrica mostrou que o grupo 3 apresentou um ganho ósseo significantemente maior quando comparado aos grupos 1 e 2 (i.e. segundo os parâmetros ET e EE, p<0,05). Além disso, os valores de ET e EE do grupo 3 foram muito próximos aos apresentados no tempo zero. Não foram observadas diferenças entre os grupos para PR e CD (p>0,05). Dentro dos limites desse estudo, pode-se concluir que a administração sistêmica do PTH (1-34) potencializou o ganho ósseo conseguido com enxertos autógenos, prevenindo a contração do enxerto. / PTH has been investigated for its benefits on bone healing and osteoporosis treatment; however, there is poor information regarding bone grafts. This study therefore investigated the effect of PTH on autogenous bone graft healing. One bone graft was harvested from the calvarium with a trephine bur (3mm internal diameter), and placed on the cortical near the mandible angle with a titanium screw. The animals were randomly assigned to: G1-(control): subcutaneous injections of vehicle solution, three-times/week (n=15); G2 - 2?g/Kg of PTH(1-34), three-times/week (n=15); G3 - 40?g/Kg of PTH(1-34), three-times/week (n=15). These animals were killed 30 days postoperatively, the specimens (implant+bed+graft) removed and used for undecalcified sections. The following histometric parameters were evaluated: total bone thickness (bed+gap+graft - TT), graft thickness (GT) (adjacent to the implant), Bone-to-implant contact (BIC), and bone area (BA) (within the limits of the threads). Five additional animals were sacrificed immediately after surgery (zero hour-ZH) to register bed and graft sizes prior to healing. G3 presented a significantly greater bone gain when compared to G1 and G2 (TT and GT, p<0,05). In relation to initial thickness (ZH), G1 and G2 showed a total contraction of 15,91% and 20,83%, respectively, while G3 showed a slight bone gain (1.21%). Data analysis revealed a significant difference for G3, when compared to G1 and G2 (p <0.01). No differences were observed for BIC and BA (p>0,05). Systemic administration of PTH (1-34) prevented graft contraction and increased bone augmentation after the autogenous bone graft healing.
123

Estudo da influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos /

Oliveira, Sérgio Ricardo de. January 2008 (has links)
Orientador: Valdir Gouveia Garcia / Banca: Maria José Hitomi Nagata / Banca: Álvaro Francisco Bosco / Banca: Ariel Lenharo / Banca: Jamil Awad Shibli / Resumo: As modalidades terapêuticas que envolvem implantes dentais têm se expandido gradativamente, sendo implantados em uma variedade de estruturas ósseas. Dessa forma, o propósito do presente trabalho foi estudar a influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos. Foram utilizados implantes de titânio c.p., grau II, cônico de 1,4mm de diâmetro e 2,7mm de comprimento, com superfície tratada. Trinta e oito ratos wistar tiveram seus primeiros molares superiores esquerdo e direito extraídos. Após 30 dias de reparo alveolar, dois animais foram sacrificados para confirmar o fim desse processo. Os demais animais tiveram os implantes instalados bilateralmente e foram divididos randomicamente em três grupos: Controle (Ctr/n=12) que não receberam nenhum tipo de tratamento; Placebo (Pl/n=12) e Tratado (Tra/n=12), que receberam injeções diárias de 1 ml de solução salina e corticosterona na dosagem de 5mg/kg, respectivamente. Trinta dias após a implantação, todos os animais foram eutanasiados e tiveram a concentração plasmática do corticóide mensurada: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) e Tra (281,37 ± 64,72 ng/ml); e o contato osso-implante determinado: Ctr (96,67%), Pla (82,22%) e Tra (15,73%), nos quais o grupo Tra apresentou-se estatisticamente diferente dos demais grupos (p<0,05). Assim, diante da metodologia empregada, foram evidenciadas menor formação óssea e conseqüente redução da área de tecido ósseo neo-formado na interface osso-implante. / Abstract: The therapeutic modalities which involves dental implants has been gradually expanded, being implanted in a variety of bone structures. In this way, the aim of the present work was to study the corticoid influence at the initial process of bone integration of titanium implants installed in rat jaws. It were used titanium implants c.p.; grade II, conic with 1,4mm diameter and 2,7mm length, with treated surface. Thirty eight wistar rats had their first upper left and right molars extracted. After 30 days of alveolar repair, two animals were sacrificed to confirm the end of this process. The others had their implants installed bilaterally and they were splited randomly in three groups: Control (Ctr/n=12) which did not receive any kind of treatment; Placebo (Pla/n=12) and Treated (Tre/n=12) which received 1ml daily shots of salt solution and corticosterone at a dosage of 5mg/Kg, respectively. Thirty days after the implantation, all the animals were euthanasiated and the plasmatic concentration of corticoid was measured: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) and Tre (281,37 ± 64,72 ng/ml); and the bone implant contact was determined: Ctr (96,67%), Pla (82,22%) and Tre (15,73%), in which the Tre group presented statistically different from the other groups (p<0,05). Thus, front the employed methodology it was shown lesser bone formation and consequent reduction of the bone tissue area neo-formed at bone-implant interface. / Doutor
124

Estudo comparativo in vivo da osseointegração em duas diferentes superfícies de implantes em liga TiAlV. Caracterização topográfica, análise de frequência por ressonância e histométrica /

Colombo, Luara Teixeira. January 2019 (has links)
Orientador: Francisley Ávila Souza / Banca: Idelmo Rabgel Garcia Junior / Banca: Osny Ferreira Júnior / Resumo: Objetivo: Avaliar o comportamento biológico do tecido ósseo ao redor de implantes manufaturados em liga Ti6Al-4V diante das superfícies modificadas por jateamento de óxido de alumínio seguido condicionamento ácido (SBAS) e a superfície usinada (MS). Material e Métodos: Dez coelhos receberam aleatoriamente 20 implantes de hexágono externo com dimensões de 4,0 mm de diâmetro e 10 mm de comprimento em suas tíbias direita e esquerda, sendo um implante de cada superfície em cada tíbia. Os implantes de ambos os grupos foram analisados através de microscopia eletrônica de varredura (MEV-EDX) e microscopia de força atômica (AFM). Discos com as mesmas superfícies foram submetidos à análise de rugosidade média (Ra) e secção transversal. Nos períodos de 3 e 6 semanas foi mensurado o coeficiente de estabilidade primária por meio da análise de frequência por ressonância (ISQ), seguido da eutanásia dos animais. As peças obtidas foram submetidas ao processamento de inclusão em resina fotopolimerizável e levadas ao micrótomo para corte calcificado. Foi mensurada em porcentagem a extensão linear de contato entre tecido ósseo mineralizado e implante (ELCOMI) e área óssea neoformada (AON). Os dados foram submetidos à análise de variância e ao teste t de Tukey. Resultados: MEV e AFM mostraram diferenças na topografia das superfícies. Os valores médios obtidos pelas análises de frequência por ressonância, Ra e secção transversal para SBAS foram estatisticamente superiores (p<0,05) quando comparad... (Resumo completo, clicar acesso eletrônico abaixo) / Objective: Evaluate the biological behavior of bone tissue around implants manufactured in Ti-6Al-4V alloy before surfaces modified by aluminum oxide blasting followed by acid etching (SBAS) and machined surface (MS).Material and Methods: Ten rabbits randomly received 20 external hexagon implants with dimensions of 4.0 mm in diameter and 10 mm in length on theirright and left tibiae, one implant of each surface on each tibia. The implants of both groups were analyzed by scanning electron microscopy (SEM-EDX) and atomic force microscopy (AFM). Disks withthe same surfaces were submitted to analysis of average roughness (Ra) and cross section. In the periods of 3 and 6 weeks, the primary stability coefficient was measured by means of resonance frequency analysis (ISQ), followed by euthanasia of the animals. The obtained pieces were submitted to the inclusion processing in photopolymerizable resin and taken to the microtome for cutting without decalcification. The bone interface contact (BIC) and neoformed bone area (NBA) was measured in percentage. Data were submitted to analysis of variance and Tukey t test. Results: SEM and AFM showed differences in surface topography. The mean values obtained by the resonance, Ra and cross sectionanalyzes for SBAS were statistically higher (p <0.05) when compared to MS. The mean values in percentage of BICfor SBAS were 69.65 and 71.56 respectively for 3 and 6 weeks, while for MS the mean values were 54.06and 55.99 respectively for the same periods. The mean values of NBAin the SBAS group were 69.86 and 79.59 for the 3 and 6 week periods, while forMS the mean values were 59.59and 74.32, respectively, in the same groups. There were statistically superior differences (p <0.05) in SBAS implants for BICin the 3 and 6 week periods and AON in the 3 week period. Conclusion: The surface modification of the SBAS implants providedchanges... (Complete abstract electronic access below) / Mestre
125

Efeitos da radioterapia na obtenção da osseointegração em ratos / Effects of radiotherapy in obtaining osseointegration in rats

Kamezawa, Leonardo Silva Gomes 11 December 2017 (has links)
Submitted by Leonardo Silva Gomes null (drleonardosgomes@gmail.com) on 2018-01-22T00:28:55Z No. of bitstreams: 1 Dissertação corrigida.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-01-23T19:48:52Z (GMT) No. of bitstreams: 1 kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Made available in DSpace on 2018-01-23T19:48:52Z (GMT). No. of bitstreams: 1 kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) Previous issue date: 2017-12-11 / A radioterapia é o uso da aplicação de radiação ionizante em áreas específicas, visando tratamento de tumores. Porém, a área irradiada e os tecidos normais circundantes estão sujeitos a danos agudos e crônicos. As injúrias no tecido ósseo variam desde osteopenia até osteorradionecrose e, devido a estas alterações, pacientes irradiados portadores de implantes vêm demonstrando maior taxa de insucesso. O objetivo deste estudo foi avaliar os efeitos da radioterapia, simulando uma dose total de um tratamento radioterápico convencional para pacientes oncológicos, na neoformação óssea e na osseointegração de implantes em fêmures de ratos. Foram utilizados neste estudo 66 ratos que receberam implantes cilíndricos de titânio comercialmente puro (TiCp) nos fêmures direito e esquerdo. Os animais foram divididos em 3 grupos: a) Grupo controle (C): cirurgia de colocação dos implantes (tecido sadio sem irradiação); b) Grupo irradiação precoce (Ip): cirurgia de colocação dos implantes seguido de irradiação após 24h; c) Grupo irradiado (I): irradiação e após 4 semanas, cirurgia de colocação dos implantes. Os animais dos grupos Ip e I foram submetidos a irradiação em 02 sessões de 15 Gy, totalizando a dose de 30 Gy. Os animais foram eutanasiados nos períodos de 2 e 7 semanas após o tratamento. Durante o experimento, os animais foram cuidadosamente monitorados quanto as alterações clínicas. Em cada período, 06 animais foram submetidos à análise histomorfométrica, visando avaliar a neoformação óssea e a interface osso-implante. Os outros 05 animais, dos períodos de 2 e 7 semanas após o tratamento, foram submetidos ao teste de torque reverso para avaliar a força de fixação osso-implante, obtida na osseointegração. Todos os dados foram estatisticamente analisados por meio da análise de variância de 2 fatores para torque reverso, porcentagem de área de formação óssea (BAFO) e porcentagem de superfície de contato osso implante (BIC) com nível de significância a 5%. O teste de Tukey foi realizado para determinação dos grupos homogêneos. A irradiação ionizante influenciou negativamente de maneira estatisticamente significante, retardando o processo de osseointegração, porém, não sendo capaz de inibí-lo. / The radiotherapy is ionizing radiation proceeding in specific areas, aiming at the treatment of tumors. However, the irradiated area and the surrounding normal tissue can develop acute and chronic damage. In bone tissue, injuries ranging from osteopenia to osteroadionecrosis and due to these changes patients irradiated with implants have shown higher failure rate. The objective of this study was to evaluate the effects of radiation, simulating a total dose of a conventional radiotherapy treatment for cancer, bone regeneration and osseointegration of implants in femurs of rats. It was used in this study 66 mice that receive cylindrical implants of commercially pure titanium (cpTi) on the right and left femurs. The animals were divided into 3 groups: a) control group (C): implant placement surgery (control group - healthy tissue without irradiation); b) Group early irradiation (Ip): placement of implants surgery followed by radiation after 24h; c) Group irradiated (I): irradiation and after 4 weeks of surgery implant placement. The animals of the Ip and I groups were subjected to irradiation in a double step at a dose of 15 Gy each, totalizing dose of 30 Gy. The animals were euthanized at periods of 2 and 7 weeks after treatment. During the experiment, the animals were carefully monitored for clinical changes. In each period 06 animals were submitted to histomorphometric analysis, to evaluate the bone formation and boneimplant interface. The other 05 animals, in periods of 2 and 7 weeks after treatment, were submitted to the reverse switch test to evaluate the strength of bone-implant fixation, obtained in osseointegration. All data were statistically analyzed by means of the 2-factor variance analysis for reverse torque, percentage of bone area fraction occupancy (BAFO) and percentage of bone implant contact (BIC) with significance level at 5%. The Tukey test was performed to determine the homogeneous groups. The ionizing radiation influenced negatively in a statistically significant way, delaying the process of osseointegration, but not being able to inhibit it.
126

Prótese protocolo com barra pré-fabricada: comportamento ósseo variando o tipo de osso e a configuração horizontal do arco mandibular no MEF-3D

Almeida, Erika Oliveira de [UNESP] 21 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-21Bitstream added on 2014-06-13T19:58:24Z : No. of bitstreams: 1 almeida_eo_me_araca.pdf: 3755451 bytes, checksum: 666f30ecb05cff86a47b4d7dfe771edb (MD5) / A barra pré-fabricada é uma opção de tratamento vantajosa por minimizar o tempo de confecção da prótese implantossuportada do tipo protocolo de carga imediata com níveis de adaptação e passividade previsíveis. No entanto, para a sua aplicação, o arco do paciente deve adaptar-se anatomicamente ao formato da barra pré-fabricada, e a qualidade óssea deve ser compatível com a indicação da carga imediata. Além disso, a literatura não apresenta dados numéricos sobre a influência de diferentes formatos horizontais do arco mandibular na distribuição das tensões no osso, assim como não é homogênea a definição do critério de análise a ser utilizado quando materiais frágeis, como o osso, são estudados utilizando o método dos elementos finitos. Devido a isso, foi realizada uma revisão da literatura com o objetivo de relacionar as propriedades dos materiais estudados com o critério de análise adotado. Para isto, foram levantados 2061 artigos através do indexador Medline database, durante os anos de 2004 a 2008. Observou-se que tanto o critério das tensões de von Mises como a máxima tensão principal foram utilizados para o estudo dos materiais considerados frágeis ou não. Para o estudo da influência de diferentes formatos horizontais do arco mandibular e diferentes tipos de osso na distribuição das tensões no osso cortical e medular na simulação de uma prótese fixa implantossuportada do tipo protocolo mandibular confeccionada através do sistema pré-fabricado Neopronto (Neodent, Implante Osseointegrável), quatro modelos (M) representativos... / Prefabricated bar is a profitable treatment option for minimizing the preparation time of fixed protocol-type prosthesis in immediate load with adaptation levels and predictable passivity. Nevertheless, in order to be applied, the patient's arch must be anatomically adapted to the format of the prefabricated bar, and bone quality must be compatible to immediate load indication. However, literature does not show any numerical data about the influence of different horizontal formats of the mandibular arch on bone stress distribution, as well as it is not homogeneous which analysis criterion is to be used when friable materials, such as the bone, are studied by making use of the finite element method. Due to this, a literature review was elaborated with the purpose to relate the materials' properties through the adopted analysis criterion. Therefore, 2061 articles were raised through the Medline Database Indexer from 2004 to 2008. It was noticed that not only Von Mises's equivalent stress criterion but also maximum principal stress were used for the study of materials considered as friable or not. For the study of the influence of different horizontal formats of mandibular archs and different types of bone in stress distribution on the cortical and medular bone in simulating a fixed implant-supported protocol-type mandibular prosthesis prepared through the Neopronto prefabricated system (Neodent, Osseointegratable Implant), four representative models (M) of a totally endentulate mandibular arch restored by the Neopronto prefabricated system (Neodent, Osseointegratable Implant) over four interforaminal implants were prepared through the SolidWorks 2007 program with a bone range (I to IV) (M.I - M.II - M.III - M.IV), considering the horizontal dimension as of regular size... (Complete abstract click electronic access below)
127

Correlação entre os efeitos da radioterapia sobre a atividade osteogênica de células mesenquimais na instalação de implantes / Radiotherapy analysis in the differentiation of mesenchymal cells before implants surgery

Godoi, Fernanda Herrera Costa 26 March 2018 (has links)
Submitted by FERNANDA HERRERA DA COSTA (ferherreracosta@gmail.com) on 2018-05-24T14:02:59Z No. of bitstreams: 1 dissertação final.pdf: 14796170 bytes, checksum: b56cc2f9884a2482b189d839e1ebdcca (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-06-06T19:33:04Z (GMT) No. of bitstreams: 1 godoi_fhc_me_sjc.pdf: 14796170 bytes, checksum: b56cc2f9884a2482b189d839e1ebdcca (MD5) / Made available in DSpace on 2018-06-06T19:33:04Z (GMT). No. of bitstreams: 1 godoi_fhc_me_sjc.pdf: 14796170 bytes, checksum: b56cc2f9884a2482b189d839e1ebdcca (MD5) Previous issue date: 2018-03-26 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A sobrevida de pacientes submetidos a tratamentos para câncer de cabeça e pescoço está aumentando e a busca por reabilitação é necessária para promover qualidade de vida. O objetivo deste estudo é avaliar o perfil da expressão gênica de transcritos relacionados na osteogênese e osteoclastogênese em uma cultura primária de células mesenquimais de fêmures de ratos submetidos a radioterapia e colocação de implantes de titânio. Setenta e dois ratos receberam implantes de titânio em ambos fêmures. Os animais foram divididos em quatro grupos: 1) Grupo controle (C): cirurgia de colocação dos implantes; 2) Implante + irradiação imediata (IrI): irurgia de implantes e seguido de irradiação imediata; 3) Implante + irradiação tardia (IrT): cirurgia de implantes e irradiação após 4 semanas; 4) Irradiação prévia + implantes (IrP): irradiação e após 4 semanas cirurgia de implantes. A dose de irradiação foi de 30 Gy fracionadas em duas sessões. As eutanásias nos períodos de 3, 14 e 49 dias após o tratamento. A células cultivadas sofreram diferenciação em osteoblastos. A expressão gênica dos genes Fosfatase alcalina (Alp), Colágeno 1 (Col-1), Integrina !1 (Itg ! ), Osteocalcina (Bglap), Osteopontina (Osp), Osteonectina (Osn), Sialoproteína Óssea (Bsp), Fator de crescimento transformador (Tgf- ! ), Osterix (Osx),Fator relacionado ao Runt (Runx2), Fator estimulador de colônias de macrófagos (M-csf), Interleucina -6 (Il-6) Apolipoproteína E (Apo-E), Prostaglandina E2 (PgE2), foram avaliados por qRT-PCR e os resultados validados por ELISA. A expressão mais alta de Alp foi encontrada no grupo IrP (p=0.0001) e foi subexpressa nos grupos IrI e IrT (p<0.0001 e p=0.0041 respectivamente). Resultados similares foram encontrados nos transcritos de Itg !, On, Bsp, Osx e Runx2. mRNA do Tgf- ! foi hiperexpresso em todos os grupos principalmente aos 49 dias. Depois de 49 dias, os níveis de proteína da Bglap e Il-6 foram correlacionados com a expressão do mRNA. A radioterapia imediata altera a atividade de diferenciaçãO das células mesenquimais dos fêmures de ratos. / Prognosis of patient submitted to head and neck cancer treatment has increased and the oral rehabilitation becomes necessary to improve their life quality. The aim of this study was to evaluate the gene expression profile of transcripts related to osteogenesis and osteoclastogenesis in primary culture of mesenchymal cells from rat femurs submitted to radiotherapy and installation of pure titanium implant. Seventy two rats received titanium implants in both femurs. The animals were divided in four groups: 1- Control (C) implant surgery; 2- Implant + immediate irradiation after 24 hours (IrI); 3- Implant + late irradiation after 4 weeks (IrL); 4- Implant + Previous irradiation 4 weeks before surgery (IrP) irradiation. The irradiation dose was 30Gy fractioned in two. The animals were euthanized in day 3, 14 and 49 after surgery. The mesenchymal cells from femurs were extracted and cultivated. The differentiation into osteoblastic cells was verified by calcification nodules formation. The gene expression of Alkaline Phosphatase (Alp), Collagen 1 (Col 1), Integrin β1 (ItgB1), Osteocalcin (Bglap), Osteopontin (Osp), Osteonectin (Osn), Bone Sialoprotein (Bsp), Transforming Growth Factor β-type (Tgf-β), Osterix (Osx), Runt-related transcription factor 2 (Runx2), Macrophage Colony- Stimulating Factor (M–csf), Interleukin-6 (Il-6), Apolipoprotein E (ApoE) and Prostaglandin E2 (PgE2) were evaluated by qRT-PCR and the results were validated by ELISA test. Higher mRNA of Alp expression was found in IrP group (p=0.0001) and it was downregulated in IrI and IrT groups (p<0.0001 and p=0.0041, respectively). Similar results were found for transcript levels of ItgB1, Osn, Bsp, Osx and Runx2. mRNA of Tgf-β was overexpressed in all groups mainly in 49 days. After 49 days, Osn and Bsp transcripts were downregulated in the 3 groups evaluated. The Bglap and IL-6 protein level was correlated to their mRNA expression. The radiotherapy alters immediately the differentiation and activity of mesenchymal cells from rat femurs; however these cells seem to recover becoming suitable for receiving implants. / FAPESP: 2016/20103-7
128

Efeitos da radioterapia no processo de neoformação óssea na interface osso/implante e na expressão de citocinas IL-6 e TGF-ß : estudo in vivo /

Costa, Bruno César Almeida. January 2018 (has links)
Orientador: Luana Marotta Reis de Vasconcellos / Coorientadora: Renata Falchete do Prado / Banca: Yasmin Rodarte Carvalho / Banca: Vivian Cristina Costa Castilho Hyodo / Resumo: No tecido ósseo, as injúrias decorrentes da radioterapia variam desde osteopenia até osteoradionecrose e devido a estas alterações, pacientes irradiados portadores de implantes vêm demonstrando maior taxa de insucesso. O objetivo neste estudo foi avaliar os efeitos da radioterapia, simulando uma dose total de um tratamento radioterápico convencional para pacientes oncológicos, na neoformação óssea ao redor de implantes instalados em fêmures de ratos, assim como na expressão de citocinas IL-6 e TGF-ß. Foram utilizados neste estudo 36 ratos que receberam implantes rosqueados de titânio grau V nos fêmures esquerdos. Os animais foram divididos em 3 grupos: a) Grupo controle (C): cirurgia de colocação dos implantes (tecido sadio sem irradiação); b) Grupo irradiação (I): irradiação e após 4 semanas cirurgia de colocação dos implantes c) Grupo irradiação imediata (IP): cirurgia de colocação dos implantes e depois de 24 horas irradiação. A irradiação foi realizada em duas etapas com doses de 15 Gy, totalizando ao final da segunda dose 30 Gy. Os animais foram eutanasiados nos períodos de 3 dias, 2 e 7 semanas após o tratamento. No momento da eutanásia, 0,5 ml de sangue foi coletado e os níveis séricos de IL-6 e TGF-β foram mensurados pelo método imunoenzimático (ELISA). Em cada período 04 animais foram submetidos à microtomografia computadorizada (µCT), visando avaliar a neoformação óssea na interface osso-implante. Os valores obtidos foram submetidos ao teste ANOVA um fator para anál... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In bone tissue, the injuries resulting from radiotherapy vary from osteopenia to osteoradionecrosis and due to these alterations, irradiated patients with implants have been showing a higher rate of failure. The objective of this study was to evaluate the effects of radiotherapy, simulating a total dose of a conventional radiotherapy treatment for cancer patients, in the new bone formation around implants in rat femurs, as well as in the expression of IL-6 and TGF-β cytokines . Thirty-six rats receiving grade V titanium implants in the left femora were used in this study. The animals were divided into 3 groups: a) Control group (C): implant placement surgery (healthy tissue without irradiation); b) Group irradiation (I): irradiation and after 4 weeks implant placement surgery c) Immediate irradiation (IP) group: implant placement surgery and after 24 hours irradiation. Irradiation was performed in two steps with doses of 15 Gy, totaling at the end of the second dose 30 Gy. The animals were euthanized at 3 days, 2 and 7 weeks after treatment. At the time of euthanasia, 0.5 ml of blood was collected and serum levels of IL-6 and TGF-β were measured by the enzyme-linked immunosorbent assay (ELISA). In each period, 04 animals were submitted to computerized microtomography (μCT), aiming to evaluate the bone neoformation at the bone-implant interface. The obtained values were submitted to ANOVA a factor for statistical analysis and when necessary the Tukey multiple comparison test (... (Complete abstract click electronic access below) / Mestre
129

Avaliação de dispositivo para viabilização de análise de frequência de ressonância em implantes dentários em ovelhas / &nbsp;

Cristiane Marques Dorce 13 April 2018 (has links)
Afirmação do problema. Estudos experimentais em animais são utilizados para avaliar previamente o resultado de pesquisas e sua necessidade de serem realizadas em humanos. Estudos em animais são fundamentais na implantodontia para que haja uma melhor compreensão da osseointegração. Durante o processo de execução de pesquisas nesse tipo de estudo, algumas dificuldades relacionadas ao manuseio, custos de manutenção e bem-estar dos animais tendem a dificultar o seu desenvolvimento. Finalidade. Esse estudo tem como objetivo, testar um novo dispositivo acoplado sobre o implante, para que possa atuar como uma extensão do mesmo, facilitando a realização da Análise de Frequência de Ressonância durante o processo de osseointegração permitindo que implantes instalados em ovelhas em diferentes períodos, possam ser reabertos sem que haja a necessidade de etapas cirúrgicas para a reabertura durante a realização de testes. Material e métodos. Foram utilizadas 4 ovelhas, sendo uma do Grupo Controle (GC) e 3 do Grupo Teste (GT). Cada animal recebeu oito implantes localizados próximos ao ângulo da mandíbula, sendo quatro do lado esquerdo e quatro do lado direito, totalizando, 32 implantes cone-morse Acqua® de 3,5 de diâmetro por 8,5mm de comprimento da empresa Neodent® que foram avaliados pela análise de frequência de ressonância com a medição do ISQ (Quociente de Estabilidade do Implante) utilizando um transdutor (SmartPeg) expressos numa escala de 0 a 100. Para o Grupo Controle (GC) as medições de ISQ foram realizadas pelo método convencional, onde o SmartPeg foi acoplado diretamente sobre a plataforma do implante. Já no Grupo Teste (GT) o dispositivo estudado, foi acoplado ao implante para que pudesse ser realizada a medição. Os períodos estudados foram: imediatamente após a cirurgia e com quatro semanas de osseointegração. Para a análise estatística foram empregados os testes de Wilcoxon e Man-Whitney com a probabilidade de 5% (p<0.05). Resultados. As médias obtidas no GC foram 50,47 imediatamente após cirurgia e 65,68 após 4 semana, enquanto que no GT foram 34,74 e 34,81, respectivamente. Comparando a diferença entre os grupos nas médias de ISQ imediatas e após quatro semanas, houve diferença significativa com p= 0.0321 e p= 0.0027, respectivamente, demonstrando que os resultados no GT nos dois períodos não foram equivalentes quando comparados ao GC. Conclusão. Os resultados demonstraram que o grupo teste, apesar de trazer benefícios em relação ao manuseio dos animais, não apresentou benefícios com relação à eficiência na leitura do ISQ, quando comparado ao método convencional. / Statement of the problem. Experimental studies in animals are used to pre-evaluate the results of research and their need to be performed in humans. Animal studies are fundamental in implantology so that there is a better understanding of osseointegration. During the execution of research in this type of study, some difficulties related to handling, maintenance costs and animal welfare tend to hinder its development. Purpose. This study aims to test a new device coupled on the implant, so that it can act as an extension of the same, facilitating the performance of the Resonance Frequency Analysis during the osseointegration process allowing implants installed in different periods of time, can be reopened without the need for surgical steps for reopening during testing. Material and methods. Four sheep were used, one being from the Control Group (GC) and 3 from the Test Group (GT). Each animal received eight implants located near the angle of the mandible, four on the left side and four on the right side, totaling 32 Acqua® 3.5 mm diameter 8.5 mm long implants of the company Neodent® that were evaluated by the resonance frequency analysis with the ISQ (Implant Stability Ratio) measurement using a transducer (SmartPeg) expressed on a scale of 0 to 100. For the Control Group (GC) the ISQ measurements were performed by the conventional method, where the SmartPeg was attached directly onto the implant platform. In the Test Group (GT) the studied device was attached to the implant so that the measurement could be performed. The periods studied were: immediately after surgery and four weeks of osseointegration. For the statistical analysis Wilcoxon and Man-Whitney tests were used, with a probability of 5% (p <0.05). Results. The averages obtained in the CG were 50.47 immediately after surgery and 65.68 after 4 weeks, while in the GT were 34.74 and 34.81, respectively. Comparing the difference between the groups in the means of immediate SAI and after four weeks, there was a significant difference with p = 0.0321 and p = 0.0027, respectively, demonstrating that the results in the WG in the two periods were not equivalent when compared to the CG. Conclusion. The results showed that the test group, despite having benefits in relation to the handling of the animals, did not present benefits in relation to the efficiency of the ISQ reading when compared to the conventional method.
130

Comportamento do tecido ósseo frente ao óxido de zinco e pastas de óxido de zinco com eugenol, guaiacol e óleo de cravo : estudo radiográfico e histológico em "Canis familiaris" /

Camargo, Hed Arruda. January 1967 (has links)
Orientador: Jose Bonifacio Fonseca / Resumo: Não disponível / Abstract: Not available / Doutor

Page generated in 0.0674 seconds