• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 39
  • 39
  • 25
  • 15
  • 13
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

CO2 capture from oxy-fuel combustion power plants

Hu, Yukun January 2011 (has links)
To mitigate the global greenhouse gases (GHGs) emissions, carbon dioxide (CO2) capture and storage (CCS) has the potential to play a significant role for reaching mitigation target. Oxy-fuel combustion is a promising technology for CO2 capture in power plants. Advantages compared to CCS with the conventional combustion technology are: high combustion efficiency, flue gas volume reduction, low fuel consumption, near zero CO2 emission, and less nitrogen oxides (NOx) formation can be reached simultaneously by using the oxy-fuel combustion technology. However, knowledge gaps relating to large scale coal based and natural gas based power plants with CO2 capture still exist, such as combustors and boilers operating at higher temperatures and design of CO2 turbines and compressors. To apply the oxy-fuel combustion technology on power plants, much work is focused on the fundamental and feasibility study regarding combustion characterization, process and system analysis, and economic evaluation etc. Further studies from system perspective point of view are highlighted, such as the impact of operating conditions on system performance and on advanced cycle integrated with oxy-fuel combustion for CO2 capture. In this thesis, the characterization for flue gas recycle (FGR) was theoretically derived based on mass balance of combustion reactions, and system modeling was conducted by using a process simulator, Aspen Plus. Important parameters such as FGR rate and ratio, flue gas composition, and electrical efficiency etc. were analyzed and discussed based on different operational conditions. An advanced evaporative gas turbine (EvGT) cycle with oxy-fuel combustion for CO2 capture was also studied. Based on economic indicators such as specific investment cost (SIC), cost of electricity (COE), and cost of CO2avoidance (COA), economic performance was evaluated and compared among various system configurations. The system configurations include an EvGT cycle power plant without CO2 capture, an EvGT cycle power plant with chemical absorption for CO2 capture, and a combined cycle power plant. The study shows that FGR ratio is of importance, which has impact not only on heat transfer but also on mass transfer in the oxy-coal combustion process. Significant reduction in the amount of flue gas can be achieved due to the flue gas recycling, particularly for the system with more prior upstream recycle options. Although the recycle options have almost no effect on FGR ratio, flue gas flow rate, and system electrical efficiency, FGR options have significant effects on flue gas compositions, especially the concentrations of CO2 and H2O, and heat exchanger duties. In addition, oxygen purity and water/gas ratio, respectively, have an optimum value for an EvGT cycle power plant with oxy-fuel combustion. Oxygen purity of 97 mol% and water/gas ratio of 0.133 can be considered as the optimum values for the studied system. For optional operating conditions of flue gas recycling, the exhaust gas recycled after condensing (dry recycle) results in about 5 percentage points higher electrical efficiency and about 45 % more cooling water consumption comparing with the exhaust gas recycled before condensing (wet recycle). The direct costs of EvGT cycle with oxy-fuel combustion are a little higher than the direct costs of EvGT cycle with chemical absorption. However, as plant size is larger than 60 MW, even though the EvGT cycle with oxy-fuel combustion has a higher COE than the EvGT cycle with chemical absorption, the EvGT cycle with oxy-fuel combustion has a lower COA. Further, compared with others studies of natural gas combined cycle (NGCC), the EvGT system has a lower COE and COA than the NGCC system no matter which CO2 capture technology is integrated. / QC 20111123
22

Influences on durability and leaching behaviour of concrete : new technologies in fly ash production

Yakub, H. I. January 2016 (has links)
This report describes a 3 year study carried out to determine the effects of modern coal power generation technologies on the properties of fly ash and how these may affect the use of the material in concrete. A total of 18 fly ashes, from 11 different sources, produced under a range of conditions and technologies were investigated. These primarily included co-combustion, low NOx, supercritical and oxy-fuel technologies, although other available materials (run-of-station, air-classified, processed and stockpiled fly ashes) were included for comparison. The initial experimental work involved physical and chemical characterization of the fly ash samples. Thereafter, tests covering fresh properties, strength development and durability were carried out on selected concretes. A fly ash level of 30% was used with w/c ratios covering the practical range considered (0.35 to 0.65). Equal strength comparisons were also made where appropriate. Finally, granular (unbound fly ash) and monolithic (fly ash concrete) leaching tests were carried out to assess the environmental implications of using the fly ashes. The results from the physical and chemical characterization tests suggest that modern technologies used for coal fired power generation can have an influence on the properties of fly ash produced. The co-combustion, oxy-fuel and in-combustion low NOx fly ashes had reduced fineness and greater LOI, which had a negative effect on foam index and water requirement of the materials. However reactivity was largely unaffected. The post-combustion low NOx and supercritical fly ashes appeared to be unaffected by their production methods compared to that produced by conventional/establish means. Tests on fresh concrete properties showed that fly ashes with high LOI and low fineness required higher SP doses than the reference PC concrete. However, fly ashes with high fineness and low surface area were found to require a lower SP dose than the PC concrete. The concrete compressive strength tests indicate that, in general, finer fly ash concretes tended to have higher strengths than those containing coarser material. However, there did not appear to be any significant difference in performance between fly ash concretes, which suggests that, although modern technologies can have an impact on fly ash properties, if account is taken of these they should not have any significant influence on strength development. Comparison with an earlier study from the 1990s considering BS EN 450-1 fly ashes showed general agreement between the data. The durability study showed that finer, low LOI fly ashes had higher chloride resistance and at equal strength fly ash concretes performed better than those with PC. Equal strength fly ash concretes covering the modern technologies were found to have similar levels of durability for sulfate attack, abrasion and carbonation. High alkali concrete (following the BS 812-123 method) gave similar expansion levels and good resistance with respect to AAR. With air-entrainment, it was found that the fly ash concretes required high doses of AEA (relative to the PC concrete), with high LOI/BET fly ashes requiring greatest quantities. At equal strength, the fly ash concretes had poorer freeze-thaw scaling resistance than PC concrete. However, the majority of the fly ashes did manage to achieve acceptable scaling resistance according to the Swedish criteria. In general, the findings of the durability study are in agreement with the earlier study from the 1990s. Overall, no effect of production technology on the durability of concrete was observed. The leaching studies showed that, in general, in both granular and concrete form, modern fly ashes met the non-hazardous waste requirements in the WAC for all components tested except chromium. For the granular test, there were instances where elevated chromium levels were observed. Similarly, the fly ash concretes failed to meet the non-hazardous limit for chromium. However, chromium from the cement may have contributed to this, since the PC reference also failed to meet this requirement. Based on the results, there is no effect of production technology on the leaching characteristics of fly ash or concrete and the materials do not appear to pose a significant environmental risk. The practical implications of the study have been considered and overall, it has been shown that modern fly ashes behave in much the same way as traditional materials, and therefore, if these materials meet the requirements of BS EN 450-1, and their properties are taken into account in the proportioning of concrete, they should give satisfactory performance.
23

Thermodynamic Properties of CO2 Mixtures and Their Applications in Advanced Power Cycles with CO2 Capture Processes

Li, Hailong January 2008 (has links)
The thermodynamic properties of CO2-mixtures are essential for the design and operation of CO2 Capture and Storage (CCS) systems. A better understanding of the thermodynamic properties of CO2 mixtures could provide a scientific basis to define a proper guideline of CO2 purity and impure components for the CCS processes according to technical, safety and environmental requirements. However the available accurate experimental data cannot cover the whole operation conditions of CCS processes. In order to overcome the shortage of experimental data, theoretical estimation and modelling are used as a supplemental approach.   In this thesis, the available experimental data on the thermodynamic properties of CO2 mixtures were first collected, and their applicability and gaps for theoretical model verification and calibration were also determined according to the required thermodynamic properties and operation conditions of CCS. Then in order to provide recommendations concerning calculation methods for engineering design of CCS, totally eight equations of state (EOS) were evaluated for the calculations about vapour liquid equilibrium (VLE) and density of CO2-mixtures, including N2, O2, SO2, Ar, H2S and CH4.   With the identified equations of state, the preliminary assessment of impurity impacts was further conducted regarding the thermodynamic properties of CO2-mixtures and different processes involved in CCS system. Results show that the increment of the mole fraction of non-condensable gases would make purification, compression and condensation more difficult. Comparatively N2 can be separated more easily from the CO2-mixtures than O2 and Ar. And a lower CO2 recovery rate is expected for the physical separation of CO2/N2 under the same separation conditions. In addition, the evaluations about the acceptable concentration of non-condensable impurities show that the transport conditions in vessels are more sensitive to the non-condensable impurities and it requires very low concentration of non-condensable impurities in order to avoid two-phase problems.   Meanwhile, the performances of evaporative gas turbine integrated with different CO2 capture technologies were investigated from both technical and economical aspects. It is concluded that the evaporative gas turbine (EvGT) cycle with chemical absorption capture has a smaller penalty on electrical efficiency, while a lower CO2 capture ratio than the EvGT cycle with O2/CO2 recycle combustion capture. Therefore, although EvGT + chemical absorption has a higher annual cost, it has a lower cost of electricity because of its higher efficiency. However considering its lower CO2 capture ratio, EvGT + chemical absorption has a higher cost to avoid 1 ton CO2. In addition the efficiency of EvGT + chemical absorption can be increased by optimizing Water/Air ratio, increasing the operating pressure of stripper and adding a flue gas condenser condensing out the excessive water. / QC 20100819
24

Thermodynamic aspects and heat transfer characteristics of HiTAC furnaces with regenerators

Rafidi, Nabil January 2005 (has links)
Oxygen-diluted Combustion (OdC) technology has evolved from the concept of Excess Enthalpy Combustion and is characterized by reactants of low oxygen concentration and high temperature. Recent advances in this technology have demonstrated significant energy savings, high and uniform thermal field, low pollution, and the possibility for downsizing the equipment for a range of furnace applications. Moreover, the technology has shown promise for wider applications in various processes and power industries. The objectives of this thesis are to analyze the thermodynamic aspects of this novel combustion technology and to quantify the enhancement in efficiency and heat transfer inside a furnace in order to explore the potentials for reduced thermodynamic irreversibility of a combustion process and reduced energy consumption in an industrial furnace. Therefore, theoretical and experimental investigations were carried out. The 2nd law of thermodynamics analyses of OdC systems have been carried out for cases in which the oxidizer is either oxygen (Flameless-oxy-fuel) or air (High Temperature Air Combustion, HiTAC). The analyses demonstrate the possibilities of reducing thermodynamic irreversibility of combustion by considering an oxygen-diluted combustion process that utilizes both gas- and/or heat-recirculation. Furthermore, the results showed that an oxygen-diluted combustion system that utilizes oxygen as an oxidizer, in place of air, results in higher 1st and 2nd law efficiencies. Mathematical models for heat regenerators were developed to be designing tools for maximized heat recovery. These models were verified by heat performance experiments carried out on various heat regenerators. Furthermore, experiments were performed in a semi-industrial test furnace. It was equipped with various regenerative burning systems to establish combustion and heat transfer conditions prevailing in an industrial furnace operating based on HiTAC. The tests were carried out at seven firing configurations, two conventional and five HiTAC configurations, for direct and indirect heating systems. Measurements of energy balance were performed on the test furnace at various configurations in order to obtain the 1st law efficiency. Moreover, local measurements of temperature, gas composition, and heat fluxes in the semi-industrial test furnace were performed to find out the main characteristics of HiTAC flame and the effects of these characteristics on the heating potential, i.e., useful heating in the furnace. In the case of HiTAC, these measurements showed uniformities of chemistry, temperature, temperature fluctuation, and heat fluxes profiles. The values of fluctuations in temperature were small. The high speed jets of the fuel and air penetrated deep into the furnace. The fuel gradually disappeared while intermediate species gradually appeared in relatively high concentrations and at broader regions inside the furnace. These findings indicate: a large reaction zone, low specific combustion intensity in the flame, low specific fuel energy release, and high heat release from this large flame. In addition to the thermodynamic limitations to the maximum temperature of the Oxygen-diluted Combustion, the low specific energy release of the fuel and the high heat release from the flame to its surroundings cause this uniform and relatively moderate temperature profile in a HiTAC flame, consequently suppressing thermal-NO formation. Heat flux and energy balance measurements showed that heating potential is significantly increased in the case of HiTAC compared to that in the conventional case, implying much more energy savings than the apparent heat recovery from the heat regenerators, and consequently much less pollutants emissions. Therefore, it is certain that this large HiTAC flame emits more thermal radiation to its surroundings than the conventional flame does, in spite of the moderate-uniform temperature profile of the flame. This intense heat flux was more uniform in all HiTAC configurations, including the indirect heating configuration, than that of the conventional-air combustion configuration. / QC 20101011
25

Thermodynamic aspects and heat transfer characteristics of HiTAC furnaces with regenerators

Rafidi, Nabil January 2005 (has links)
<p>Oxygen-diluted Combustion (OdC) technology has evolved from the concept of Excess Enthalpy Combustion and is characterized by reactants of low oxygen concentration and high temperature. Recent advances in this technology have demonstrated significant energy savings, high and uniform thermal field, low pollution, and the possibility for downsizing the equipment for a range of furnace applications. Moreover, the technology has shown promise for wider applications in various processes and power industries.</p><p>The objectives of this thesis are to analyze the thermodynamic aspects of this novel combustion technology and to quantify the enhancement in efficiency and heat transfer inside a furnace in order to explore the potentials for reduced thermodynamic irreversibility of a combustion process and reduced energy consumption in an industrial furnace. Therefore, theoretical and experimental investigations were carried out.</p><p>The 2nd law of thermodynamics analyses of OdC systems have been carried out for cases in which the oxidizer is either oxygen (Flameless-oxy-fuel) or air (High Temperature Air Combustion, HiTAC). The analyses demonstrate the possibilities of reducing thermodynamic irreversibility of combustion by considering an oxygen-diluted combustion process that utilizes both gas- and/or heat-recirculation. Furthermore, the results showed that an oxygen-diluted combustion system that utilizes oxygen as an oxidizer, in place of air, results in higher 1st and 2nd law efficiencies.</p><p>Mathematical models for heat regenerators were developed to be designing tools for maximized heat recovery. These models were verified by heat performance experiments carried out on various heat regenerators.</p><p>Furthermore, experiments were performed in a semi-industrial test furnace. It was equipped with various regenerative burning systems to establish combustion and heat transfer conditions prevailing in an industrial furnace operating based on HiTAC. The tests were carried out at seven firing configurations, two conventional and five HiTAC configurations, for direct and indirect heating systems.</p><p>Measurements of energy balance were performed on the test furnace at various configurations in order to obtain the 1st law efficiency. Moreover, local measurements of temperature, gas composition, and heat fluxes in the semi-industrial test furnace were performed to find out the main characteristics of HiTAC flame and the effects of these characteristics on the heating potential, i.e., useful heating in the furnace. In the case of HiTAC, these measurements showed uniformities of chemistry, temperature, temperature fluctuation, and heat fluxes profiles. The values of fluctuations in temperature were small. The high speed jets of the fuel and air penetrated deep into the furnace. The fuel gradually disappeared while intermediate species gradually appeared in relatively high concentrations and at broader regions inside the furnace. These findings indicate: a large reaction zone, low specific combustion intensity in the flame, low specific fuel energy release, and high heat release from this large flame. In addition to the thermodynamic limitations to the maximum temperature of the Oxygen-diluted Combustion, the low specific energy release of the fuel and the high heat release from the flame to its surroundings cause this uniform and relatively moderate temperature profile in a HiTAC flame, consequently suppressing thermal-NO formation.</p><p>Heat flux and energy balance measurements showed that heating potential is significantly increased in the case of HiTAC compared to that in the conventional case, implying much more energy savings than the apparent heat recovery from the heat regenerators, and consequently much less pollutants emissions. Therefore, it is certain that this large HiTAC flame emits more thermal radiation to its surroundings than the conventional flame does, in spite of the moderate-uniform temperature profile of the flame. This intense heat flux was more uniform in all HiTAC configurations, including the indirect heating configuration, than that of the conventional-air combustion configuration.</p>
26

Parametry procesu spalování při využití vzduchu s obsahem kyslíku vyšším než 21 % / Characteristic parameters of oxygen-enhanced combustion process

Dřímal, Jiří January 2014 (has links)
The thesis is focused on the experimental investigation of the oxygen enhanced combustion technology (OEC), which uses the combustion air with higher concentration of oxygen, i.e. more than 21 %. The OEC technology is used in those industrial applications, which requires higher thermal efficiency, increased productivity, improved character of the flame, reduced equipment cost, lower volume of exhaust gases and improved product quality. Although this technology involves a number of advantages, it is appropriate to mention some of its disadvantages such as refractory damage, inconsistent heating, increased pollutant emission or flame disturbance and/or flashback. The combustion tests of OEC were carried out at the burners testing facility that enables to test many types of burners (gaseous, liquid, or combined). The two-staged low-NOx burner fired by natural gas was used during the tests. The observed parameters include the effect of oxygen concentration in the combustion air on the NOx emissions, heat flux into the wall of the combustion chamber, in-flame temperature distribution in the horizontal symmetry plane of the combustion chamber and also the shape and dimensions of the flame. The combustion tests of the air-enrichment, air-oxy/fuel and O 2 lancing OEC methods were carried out at the burner thermal input of 750 kW and air excess of 1,1 for two combustion regimes, namely one-staged and two-staged fuel supply.
27

Climate Neutral Roadmap in Fossil Free Competitiveness for Paroc, Sweden : what Paroc can do to meet up with the roadmap from Fossil Free Sweden / Klimatneutral Färdplan i Fossilfri Konkurrenskraft för Paroc, Sverige : vad Paroc kan göra för att möta upp färdplanen från Fossilfritt Sverige

Mörk, Felix January 2021 (has links)
Today’s society is standing in front of a revolution where fossil energy should be replaced with renewable energy. Governmental agencies and policy makers have formed goals and regulations to become greener, and the organisation Fossil Free Sweden has published roadmaps for fossil free competitiveness. Therefore, this report has connected Paroc’s operations with a roadmap for fossil free competitiveness to form a strategic environmental plan. Early, it was recognized that the field was big and a limitation to CO2-emissions during production were established. The facts were gathered mostly throughout literature studies, scientific publications/articles, and personal communication with personnel at Paroc/Owens Corning. The results gave a description over fossil free competitiveness for the construction sector, previous, and current sustainability efforts at Paroc. After that, the report lifted suggestions of modifications to the mainstream process. Focus laid on the reduction of coke, propane, and dolomite. Later, the report discussed a possible strategy to become fossil free by 2045. It found out that there are many approaches to become climate neutral. Moreover, a need for practical testing of the solutions in the mainstream processes, and that emissions can be calculated in an absolute of relative way.
28

Comparative Techno-Economic Analysis of Carbon Capture Processes: Pre-Combustion, Post-Combustion, and Oxy-Fuel Combustion Operations

Kheirinik, M., Ahmed, Shaab, Rahmanian, Nejat 13 December 2021 (has links)
Yes / Evaluation of economic aspects is one of the main milestones that affect taking rapid actions in dealing with GHGs mitigation; in particular, avoiding CO2 emissions from large source points, such as power plants. In the present study, three kinds of capturing solutions for coal power plants as the most common source of electricity generation have been studied from technical and economic standpoints. Aspen HYSYS (ver.11) has been used to simulate the overall processes, calculate the battery limit, and assess required equipment. The Taylor scoring method has been utilized to calculate the costliness indexes, assessing the capital and investment costs of a 230 MW power plant using anthracite coal with and without post-combustion, pre-combustion, and oxy-fuel combustion CO2 capture technologies. Comparing the costs and the levelized cost of electricity, it was found that pre-combustion is more costly, to the extent that the total investment for it is approximately 1.6 times higher than the oxy-fuel process. Finally, post-combustion, in terms of maturity and cost-effectiveness, seems to be more attractive, since the capital cost and indirect costs are less. Most importantly, this can be applied to the existing plants without major disruption to the current operation of the plants.
29

Development of Cold Gas Dynamic Spray Nozzle and Comparison of Oxidation Performance of Bond Coats for Aerospace Thermal Barrier Coatings at Temperatures of 1000°C and 1100°C

Roy, Jean-Michel L. 08 February 2012 (has links)
The purpose of this research work was to develop a nozzle capable of depositing dense CoNiCrAlY coatings via cold gas dynamic spray (CGDS) as well as compare the oxidation performance of bond coats manufactured by CGDS, high-velocity oxy-fuel (HVOF) and air plasma spray (APS) at temperatures of 1000°C and 1100°C. The work was divided in two sections, the design and manufacturing of a CGDS nozzle with an optimal profile for the deposition of CoNiCrAlY powders and the comparison of the oxidation performance of CoNiCrAlY bond coats. Throughout this work, it was shown that the quality of coatings deposited via CGDS can be increased by the use of a nozzle of optimal profile and that early formation of protective α-Al2O3 due to an oxidation temperature of 1100°C as opposed to 1000°C is beneficial to the overall oxidation performance of CoNiCrAlY coatings.
30

Development of Cold Gas Dynamic Spray Nozzle and Comparison of Oxidation Performance of Bond Coats for Aerospace Thermal Barrier Coatings at Temperatures of 1000°C and 1100°C

Roy, Jean-Michel L. 08 February 2012 (has links)
The purpose of this research work was to develop a nozzle capable of depositing dense CoNiCrAlY coatings via cold gas dynamic spray (CGDS) as well as compare the oxidation performance of bond coats manufactured by CGDS, high-velocity oxy-fuel (HVOF) and air plasma spray (APS) at temperatures of 1000°C and 1100°C. The work was divided in two sections, the design and manufacturing of a CGDS nozzle with an optimal profile for the deposition of CoNiCrAlY powders and the comparison of the oxidation performance of CoNiCrAlY bond coats. Throughout this work, it was shown that the quality of coatings deposited via CGDS can be increased by the use of a nozzle of optimal profile and that early formation of protective α-Al2O3 due to an oxidation temperature of 1100°C as opposed to 1000°C is beneficial to the overall oxidation performance of CoNiCrAlY coatings.

Page generated in 0.0619 seconds