• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • 10
  • 10
  • 10
  • 10
  • 9
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 78
  • 78
  • 58
  • 58
  • 48
  • 39
  • 29
  • 28
  • 22
  • 15
  • 15
  • 14
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Influência da inserção de fibras de Al2O3/GdAlO3 na resistência mecânica de monolayers e bilayers de cerâmicas odontológicas / Flexural strength of ceramic monolayers and bilayers bars reinforced by Al2O3/GdAlO3 fibers

Sgura, Ricardo 20 May 2010 (has links)
O presente estudo avaliou a adição de fibras cerâmicas de 0,5mm de diâmetro de Al2O3/GdAlO3 obtidas por fusão a laser (método LHPG - laser heated pedestal growth) em porcelanas de cobertura dos sistemas In Ceram Alumina, In-Ceram 2000 Al Cubes e In-Ceram 2000 YZ Cubes para CEREC (VITA Zahnfabrik). Barras confeccionadas apenas com a porcelana de cobertura (VM7 ou VM9 - monolayers) ou constituídas por ambas a cerâmica da infraestrutura e porcelana de cobertura (bilayers) receberam as fibras dispostas longitudinalmente nas proporções de 10 ou 17% vol. Barras que não receberam fibras serviram como controle dos grupos. Os corpos-de-prova (CP) com fibras assim como os do grupo controle foram submetidos a um teste de flexão em três pontos. Foram calculadas as médias para a densidade e resistência à flexão dos CP, assim como para as fibras isoladamente. A tenacidade à fratura das fibras também foi mensurada. Em todos os casos a análise de variância de um fator e o teste de Tukey com 5% de significância foram aplicados. Microscopia eletrônica de varredura foi utilizada para caracterização microestrutural das fibras e para estudo fractográfico. Foram realizadas análises de difratometria por raio-x dos materiais cerâmicos nos estados pré e pós-sinterização, assim como foram determinados os coeficientes de expansão térmico-linear das porcelanas de cobertura por dilatometria. Os CP monolayers da porcelana VM9 contendo fibras apresentaram, após a sinterização, trincas e falhas, o que impediu a continuidade dos testes com os grupos de cerâmicas do sistema In-Ceram 2000 YZ Cubes. Os CP com fibras adicionadas à porcelana VM7 em 17% vol. apresentaram resistência à flexão aumentada em 43% comparados aos CP do grupo controle, sem fibras. Nos grupos bilayers as fibras propiciaram aumento apenas numérico da resistência à flexão do conjunto, porém de forma não significante. / This study evaluated the addition of 0.5mm of diameter Al2O3/GdAlO3 fibers obtained by LHPG (Laser Heated Pedestal Growth) to veneering porcelains of the following materials: porcelain monolayers: VM7 and VM9; Bilayers: In-Ceram Alumina + VM7, In-Ceram 2000 AL Cubes + VM7 and In-Ceram 2000 YZ Cubes for CEREC + VM9 (VITA Zahnfabrik). The specimens (bars) were composed by only the veneer porcelain (monolayer) or both the veneer and the framework (bilayer). The new ceramic composites contained longitudinal fibers in 10 or 17% vol. Specimens without fibers were used as control. A metallic device was developed for the standardization of the fibers position inside the specimens. The means of the fracture toughness, density and flexural strength of the developed fibers were calculated as well as the density and flexural strength of the composites. One way ANOVA and a Tukey test (5%) were applied. Characterizations of fiber/porcelain interface and fractographyc analysis were carried out after scanning electronic microscopy (SEM) of bars. X-ray difratometry and dilatometry were also performed. Vm9 porcelain showed incompatibility with the fibers, probably due to differences between the coefficients of thermal expansion of fibers and porcelain. VM7 monolayers with the addition of 17% of fibers in volume showed significantly higher resistance in relation to control. It was concluded that the inclusion of ceramic fibers of Al2O3/GdAlO3 to veneer porcelain improves its flexural strength.
62

Avaliação biomecânica de prótese parcial fixa com cantilever sobre implantes em região posterior da mandíbula: estudo comparativo in vitro / Biomechanical evaluation of implant-supported cantilever fixed partial denture in posterior region of the mandible: in vitro comparative study

Raniel Fernandes Peixoto 28 June 2017 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, uma alternativa às cirurgias de enxerto ósseo, pouco empregada e estudada, é a utilização de prótese parcial fixa (PPF) com cantilever distal. Pensando no material de infraestrutura que garanta resistência adequada para suportar as forças mastigatórias em longo prazo, aliado ao desenvolvimento da zircônia (Zr) e da tecnologia CAD/CAM, o objetivo deste estudo foi avaliar o desajuste vertical, perda de torque, resistência à fratura do cantilever e distribuição de tensões em PPFs parafusadas sobre implantes do tipo cone morse, confeccionadas em diferentes materiais de infraestrutura (Co-Cr [Fundição Convencional] e Co-Cr e Zr [CAD/CAM]) e posicionadas na área correspondente à região posterior da mandíbula. Foram confeccionadas 40 PPFs com cantilever distal e distribuídas em 5 grupos (n=8), de acordo com o material da infraestrutura: 1 Co-Cr (Fundição convencional soldagem a laser); 2 Co-Cr (Fundição convencional soldagem TIG); 3 Co-Cr (Fundição convencional monobloco); 4 Co-Cr (CAD/CAM) e 5 Zr (CAD/CAM). A análise do desajuste vertical foi realizada em 4 momentos distintos, com auxílio de estereomicroscopia (aumento de 50×) e usando o método de Sheffiled: T0 Infraestrutura no modelo mestre; T1 Infraestrutura no modelo de poliuretano, antes da aplicação do revestimento cerâmico; T2 PPF após aplicação do revestimento cerâmico e antes da ciclagem termomecânica e T3 PPF após da ciclagem termomecânica. A avaliação do afrouxamento de parafusos foi realizada antes (T2) e após (T3) a ciclagem termomecânica e foi obtida com o auxílio de um torquímetro digital com precisão de 0,1 N.cm. Para a realização da ciclagem termomecânica as PPFs foram posicionadas na máquina de ensaio e uma carga de 120 N foi aplicada sobre elas, buscando simular 14 meses de utilização (1.200.000 ciclos). A resistência máxima à fratura do cantilever foi determinada por meio do ensaio de flexão e, para isso, uma carga perpendicular ao longo eixo da peça protética foi aplicada, com uma velocidade de aproximação de 0,5 mm/min. Uma nova PPF para cada grupo foi confeccionada para ser utilizada na avaliação da distribuição de tensões quando elas foram submetidas a carregamento puntiforme no cantilever e oclusal distribuído (150 N), por meio de análise fotoelástica. Em geral, PPFs com infraestruturas em monobloco (G3) apresentaram maiores desajustes verticais, especialmente no elemento solto da segunda e terceira condição experimental e foram associados com maior concentração de tensões, tanto no carregamento puntiforme (360,07 kPa) quanto oclusal distruído (302,46 kPa). Por outro lado, infraestruturas obtidas por meio do sistema CAD/CAM mostraram os menores desajustes verticais, se assemelhando estatisticamente (p>0,05), em vários momentos, com infraestruturas soldadas e melhores distribuições de tensões, atingindo valores inferiores a 280 kPa no carregamento puntiforme e a 200 kPa no oclusal distribuído. A moldagem de transferência (T0 &rarr; T1) e a ciclagem termomecânica (T2 &rarr; T3) pouco influenciaram no desajuste vertical dos grupos. Já o processo de aplicação do revestimento cerâmico (T1 &rarr; T2) e o seu efeito cumulativo com a ciclagem termomecânica (T1 &rarr; &rarr; T3) foram responsáveis por alterações consideráveis no desajuste vertical dos grupos, sobretudo naqueles fundidos convencionalmente (G1, G2 e G3). A ciclagem termomecânica teve um efeito considerável no percentual de perda de torque intragrupo (pMolar=0,039; pPré-molar=0,044), embora comparações entre os diferentes grupos não tenham demonstrado significância estatística (pMolar=0,116; pPré-molar=0,334). PPFs com infraestrutura metálica (>410,83±72,26 N) apresentaram resistência à fratura consideravelmente maior (p<0,05) do que a zirconia (277,47±39,10 N) e os primeiros sinais de fratura do revestimento cerâmico foram observados em torno de 900 N. Dentro das limitações deste estudo, PPFs com infraestruturas confeccionadas por meio do sistema CAD/CAM foram associadas com melhor adaptação cervical e distribuição de tensões, embora a secção das infraestruturas seguida de soldagem pode também ser uma alternativa viável, com base na proximidade dos valores de desajustes verticais e distribuição de tensão. Adicionalmente, PPFs com infraestruturas em zircônia podem ser usadas com certo grau de segurança, tendo em vista a boa adaptação marginal e distribuição de tensões, bem como altos valores de resistência à fratura constatados. / In cases of severe vertical bone loss, especially in posterior region of the mandible, an alternative to bone graft surgery, little used and studied, is the use of implant-supported cantilever fixed partial denture (FPD). Thinking about the framework material that ensures adequate strength to resist the masticatory loads in long term, together with the development of zirconia (Zr) and of CAD/CAM technology, the aim of this study is to evaluate the vertical misfit, torque loss and fracture resistance of cantilever and stress distribution in FPDs screwretained on Morse taper implants, fabricated with different framework materials (Co-Cr [Conventional Casting] and Co-Cr and Zr [CAD/CAM]) and positioned on the posterior region of the mandible. Forty FPDs with distal cantilever were fabricated and distributed into 5 groups (n=8), according to framework material: 1 Co-Cr (Conventional casting laser welding); 2 Co-Cr (Conventional casting TIG welding); 3 Co-Cr (Conventional casting one-piece); 4 Co-Cr (CAD/CAM) and 5 Zr (CAD/CAM). Analysis of vertical misfit was performed in 4 different moments, using stereomicroscopy (50× magnification) and the Sheffield method: T0 Framework on master model; T1 Framework on polyurethane model, before the ceramic veneering application; T2 FPD after application of the ceramic veneering and before the thermomechanical cycling and T3 FPD after thermomechanical cycling. Evaluation of screw loosening was performed before (T2) and after (T3) thermomechanical cycling and was obtained by a digital torque wrench with an accuracy of 0.1 N.cm. To perform the thermomechanical cycling, FPDs were positioned in the testing machine, and a 120 N load was applied on them, seeking to simulate 14 months of use (1,200,000 cycles). Fracture maximum resistance of the cantilever was determined by the flexural test and, therefore, a perpendicular force on the cantilever was applied at a crosshead speed of 0.5 mm/min. A new FDP for each group was fabricated to be used in the evaluation of the stress distribution, when they were submitted to punctiform on the cantilever and oclusal distributed loads (150 N), by the photoelastic analysis. In general, FPDs with one-piece frameworks (G3) presented higher vertical misfits, especially in the element not tightened of the second and third experimental conditions, and were associated with higher stress concentration in both the punctiform (360.07 kPa) and oclusal distributed (302.46 kPa) loads. On the other hand, the frameworks obtained by the CAD/CAM system showed the smaller vertical misfits, being statistically similar (p>0.05) to welded frameworks at various times, and better stress distributions, reaching values less than 280 kPa in the punctiform load and 200 kPa in the occlusal distributed load. Transfer impression (T0 &rarr; T1) and thermomechanical cycling (T2 &rarr; T3) had little effect on vertical misfit of the groups. The application process of the ceramic veneering (T1 &rarr; T2) and its cumulative effect with thermomechanical cycling (T1 &rarr;T3) were responsible for considerable changes in vertical misfit of the group, especially in those conventionally cast (G1, G2 and G3). A thermomechanical cycling had considerable effect in the percentage of intragroup torque loss (pMolar=0.039; pPré-molar=0.044), although comparisons between the different groups did not show statistical significance (pMolar=0.116; pPrémolar= 0.334). FPDs with metal frameworks (>410.83±72.26 N) showed considerably higher fracture resistance (p<0.05) than zirconia (277.47±39.10 N) and the first signs of fracture of the ceramic veneering were observed around 900 N. Within the limitations of this study, FPDs with frameworks fabricated using the CAD/CAM system were associated with better cervical adaptation and stress distribution, although the section of the frameworks followed by welding may also be a viable alternative, based on the proximity of the values of vertical misfits and stress distribution. Additionally, FPDs with zirconia frameworks can be used with some degree of security, considering the good marginal adaptation and stress distribution, as well as high values of fracture resistance verified.
63

Efeitos do uso de próteses múltiplas implantossuportadas, unidas e isoladas, nas tensões geradas em áreas posteriores da mandíbula / Load transfer characteristics in the posterior region of the mandible of implant supported, splinted and non-splinted restorations

Tiossi, Rodrigo 21 December 2010 (has links)
O comportamento biomecânico de próteses implantossuportadas foi analisado por fotoelasticidade e por correlação de imagens digitais (CID). Este trabalho estudou o comportamento biomecânico de próteses parciais fixas parafusadas sobre implantes, com coroas isoladas ou unidas, simulando a reabilitação de área posterior mandibular, com e sem a presença de elemento dental distal aos implantes. Devido às dificuldades em produzir estruturas múltiplas com assentamento passivo, alguns autores sugerem que implantes adjacentes sejam restaurados por próteses unitárias, minimizando os efeitos das tensões transferidas aos implantes. A análise fotoelástica é uma técnica experimental para análise de tensões, bastante empregada devido à sua relativa simplicidade e confiabilidade quanto à correspondência clínica dos achados observados. A análise por correlação de imagens digitais produz o mapeamento completo das tensões geradas na superfície do modelo analisado, possibilitando análises precisas. Não existe consenso na literatura quanto ao melhor planejamento protético para reabilitações parciais com múltiplos implantes adjacentes, a fim de minimizar as tensões geradas na interface osso-implante. O material de recobrimento estético empregado na restauração protética também foi analisado (cerâmica e resina). O modelo de estudo foi composto por um pré-molar em resina, dois implantes (Titamax GT - 4,0 x 11,0 mm - Neodent) substituindo o 2º pré-molar e o 1º molar, e um 2º molar em resina. Outro modelo foi produzido sem a presença do 2º molar. Os grupos analisados foram: UC - coroas unidas e recobertas por cerâmica; IC - coroas isoladas e recobertas por cerâmica; UR - coroas unidas e recobertas por resina; IR - coroas isoladas e recobertas por resina. O efeito do torque na fixação das estruturas foi avaliado por meio de análise fotoelástica. Análise fotoelástica qualitativa e quantitativa foi realizada após a aplicação de carga vertical puntiforme (50 N) na superfície oclusal da coroa substituindo o 1º molar. A análise por correlação de imagens também foi feita qualitativa e quantitativamente, com a carga aplicada na mesma posição que para a análise fotoelástica, mas com maior intensidade (250 N). Tensões na direção horizontal (&epsilon;xx) e de cisalhamento (&epsilon;xy) foram analisadas e comparadas pelo método CID. Os dois métodos para análise de tensões aplicados neste estudo foram satisfatórios e adequados para as comparações necessárias ao trabalho proposto. De acordo com os resultados obtidos, pode-se concluir que a esplintagem de coroas sobre múltiplos implantes adjacentes promoveu melhor distribuição de tensões em torno dos implantes e pelas estruturas de suporte, principalmente quando o contato proximal distal esteve ausente. As tensões totais no modelo não foram influenciadas pela presença do 2º molar, mas este dente participou da distribuição de tensões entre as estruturas. O material de recobrimento das coroas não foi significativo para as tensões transferidas ao modelo fotoelástico e para as tensões compressivas (&epsilon;xx). As tensões de cisalhamento (&epsilon;xy) foram influenciadas diretamente pela presença do 2º molar inferior e, com sua ausência, um material de recobrimento com baixo módulo de elasticidade (resina) foi significativo para minimizar estas tensões. / A photoelastic stress analysis and a digital image correlation (DIC) method were used to analyze the biomechanical behavior of implant supported prosthesis. This study compared the biomechanical behavior of screwed, splinted and non-splinted, implant supported fixed partial dentures, simulating the rehabilitation of a mandibular posterior region, with and without the presence of a second molar proximal contact. Since complete passivity is difficult to achieve when splinted restorations supported by multiple implants are used, some authors suggest individually restoring adjacent implants to allow for a passive fit in the resulting restorations, thus reducing the strains transferred to the implants. Photoelasticity is an experimental technique for stress analysis and has been constantly used due its simplicity, reliable results and correlation with clinical findings. The digital image correlation method is capable of providing a full-field surface strain measurement, allowing for an accurate analysis. The ideal restoration of a partially edentulous space remains controversial as to the best prosthetic design for a partial rehabilitation with multiple implants in order to minimize the strains transferred to the bone-implant interface. The influence of the veneering materials was also compared (porcelain and resin). An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants (Titamax GT - 4.0 x 11.0 mm - Neodent) replacing the second premolar and first molar. Another model was made without the presence of the second molar. Groups were: UC - porcelain-veneered splinted crowns; IC - porcelain-veneered non-splinted crowns; UR - resin-veneered splinted crowns; IR - resin-veneered non-splinted crowns. Strains transferred to the photoelastic model were analyzed after tightening the prosthetic screws. Qualitative and quantitative photoelastic stress analysis was performed after the application of a vertical load (50 N) on the occlusal surface of the crown replacing the first molar. The image correlation analysis was also performed qualitatively and quantitatively, with the load applied in the same position as for the photoelastic analysis, although with greater intensity (250 N). Strains in the horizontal direction (&epsilon;xx) and shear strains (&epsilon;xy) were analyzed and compared with the DIC method. Both methods for strain analysis used in this study performed satisfactory and are adequate for the comparisons proposed in this work. According to the results found, it can be concluded that splinting multiple adjacent implant supported crowns provided a better strain distribution around the implants and the supporting structures, especially when the distal proximal contact was absent. The total strains in the model were not influenced by the presence of a distal proximal contact, but the presence of the second molar optimized the strain distribution between the structures. The crowns veneering material was not significant for the strains transferred to the photoelastic model and for compressive strains (&epsilon;xx). Shear strains (&epsilon;xy) were influenced by the presence of the second molar, and when it was absent, the use of a veneering material with low elasticity modulus (resin) significantly reduced these tensions.
64

Força de mordida em pacientes com fissura labiopalatina reabilitados com próteses parciais fixas sobre dentes naturais e implantes / BITE FORCE IN PATIENTS WITH REHABILITATED CLEFT LIP AND PALATE WITH PARTIALLY FIXED PROSTHESES ON NATURAL TEETH AND IMPLANTS

Tavano, Rafael D'Aquino 31 July 2015 (has links)
As fissuras palatinas além de envolvem o osso alveolar podem promover a ausência do dente incisivo lateral ou apresenta-lo severamente comprometido. Nesses casos sua reabilitação poderá ser feita por próteses parciais fixas convencionais ou por prótese sobre implantes, geralmente após uma cirurgia de enxerto ósseo na região. Todavia além da estética, se faz necessário investigar sobre o potencial de força oclusal que essas reabilitações proporcionam. Assim, o propósito desse estudo foi avaliar a força máxima de mordida em indivíduos com fissura labiopalatina unilateral reabilitados com prótese parcial fixa convencional e sobre implantes e comparar esses resultados com o lado contralateral e com indivíduos sem fissura. A amostra foi constituída por 50 indivíduos, 25 pacientes com fissura (15 reabilitados com próteses parciais fixas convencionais e 10 sobre implantes) e 25 indivíduos sem fissura com dentes naturais. A força de mordida máxima foi mensurada por um único examinador utilizando o gnatodinamômetro, registrado nas regiões reabilitadas de incisivo lateral e canino, região de molares e incisivos centrais. Os valores médios obtidos, e a análise estatística com os testes t de Student e t de Student pareado permitiram observar que no mesmo indivíduo, a força de mordida do lado não afetado foi estatisticamente superior quando comparado com o lado da fissura reabilitado com prótese (p=0,005). O grupo reabilitado com prótese fixa convencional apresentou a força máxima de mordida estatisticamente igual ao grupo com prótese fixa sobre implante (p=0,781). Considerando os grupos experimental e controle na região de molares os resultados foram estatisticamente iguais (lado afetado p=0,082 e não afetado p=0,066). Na região de incisivo lateral e canino, o lado correspondente ao afetado no grupo-controle, apresentou força máxima de mordida estatisticamente maior que o grupo-experimental (p=0,004), enquanto no lado correspondente ao não afetado os resultados foram iguais. Na região de incisivos centrais o resultado médio do grupo-controle também foi estatisticamente maior que o experimental (p=0,005) / The cleft palate involving the alveolar bone may have the lateral incisor tooth missing or severely compromised. In such cases rehabilitation can be done through fixed dental prostheses or implant-supported fixed dental prostheses, generally after a bone graft surgery in the region. However, beyond aesthetics, it is necessary to investigate the potential for occlusal force that these rehabilitations provide. Thus, the purpose of this study was to evaluate the maximum bite force in subjects with unilateral cleft lip and palate rehabilitated with fixed dental prostheses or implantsupported fixed dental prostheses and compare the results with the contralateral side and with individuals without cleft. The sample consisted of 50 subjects, 25 patients with cleft (15 rehabilitated with fixed dental prostheses and 10 with implant-supported fixed dental prostheses) and 25 individuals without cleft and with natural teeth. The maximum bite force was measured by means of gnathodynamometer, registered in the rehabilitated lateral incisor and canine region, molars region and incisors regions by a single examiner. The obtained average values, and the statistical analysis with the Student t test and paired Student t test allowed to be observed that on the same individual the bite force on the side that was not affected was statistically superior when compared to the side of the rehabilitated cleft with prosthesis (p=0,005). The rehabilitated group with conventional prostheses presented maximum bite force statistically equal to the group with the implant-supported fixed dental prostheses (p=0,781). Considering the experimental and control groups on the molar regions, the results were statistically equal (affected side p=0,082 e non-affected p=0,066). The lateral incisor and canine region from the correspondent affected side on the control group presented maximum bite force statistically higher than the experimental group (p=0,004), on the non-affected side the results were the same. In the incisor region, the average result of the control group was also statistically higher than the experimental group (p=0,005)
65

Prótese parcial fixa em pacientes com fissura labiopalatina / Fixed partial prosthesis in patients with cleft lip and palate

Gelmini, Mariana 18 November 2011 (has links)
Introdução: A ausência do incisivo lateral superior é freqüente em indivíduos com fissuras que envolvem o rebordo alveolar. As próteses parciais fixas convencionais, apesar de se tratar de procedimento não conservativo devido ao desgaste dos dentes adjacentes à fissura, podem oferecer resultados funcional e estético satisfatórios. Objetivos: Avaliar a estética da prótese e do sorriso após reabilitação com prótese parcial fixa na área da fissura, avaliar clinicamente as condições biológicas do periodonto de proteção na área correspondente à prótese e analisar o grau de satisfação dos pacientes após tratamento. Material e Métodos: Foram selecionados 40 pacientes, de ambos os gêneros, com fissura transforame incisivo e pré-forame incisivo unilateral completa, reabilitados com prótese parcial fixa na área do incisivo lateral superior ausente. Esses foram fotografados, para posterior análise por três grupos de examinadores, que classificaram a estética das próteses como agradável, aceitável e desagradável. Questionários e escala analógica visual foram utilizados para avaliar o grau de satisfação dos pacientes. Para análise estatística foram obtidos valores médios, mediana e desvio padrão e utilizados coeficiente Kappa conforme caracterizado por Landis e Koch (1977), teste de Kruskal Wallis e coeficiente de Spearman, adotando-se nível de significância 5%. Resultados: A fissura transforame incisivo unilateral correspondeu a 62,5% dos casos. Não houve diferença estatisticamente significante entre os grupos de examinadores, que consideraram prótese esteticamente aceitável e a concordância interjuízes foi considerada de moderada a substancial. Para os pacientes, a estética da prótese foi considerada satisfatória para 65% e aceitável para 22,5%. Conclusão: A maioria dos casos clínicos foi considerada prótese esteticamente aceitável, sendo que as próteses devem ser melhoradas no que diz respeito à curvatura incisal e tamanho das coroas. A ausência de papila gengival e sua reposição artificial foram observadas na maioria dos casos clínicos. A maioria dos pacientes considerou a prótese satisfatória em relação à estética e também em relação à estética do sorriso; mais estudos tornam-se necessários para se alcançar excelência no tratamento dos pacientes com fissuras. / Introduction: The absence of the lateral incisor is frequent in individuals with clefts involving the alveolar crest. The conventional prosthesis fixed partial , despite the fact that isn´t a conservative procedure, may offer results functional and aesthetic satisfactory. Objectives: To evaluate the aesthetics of the prosthesis and the smile after rehabilitation with prosthesis fixed partial in the area of the cleft, to evaluate clinically the biological conditions of the periodontium of protection in the area corresponding to the prosthesis installed and analyze the degree of patient satisfaction after treatment. Material and Methods: The sample included 40 patients of both genders, with complete unilateral cleft lip and palate, rehabilitated with partial prosthesis sets in the area of the lateral incisor absent. These patients were photographed for later analysis by groups of examiners, the prostheses of the patients were classified as aesthetically pleasing, aesthetically acceptable and aesthetically unpleasant. Questionnaires and visual analog scale were used to assess the degree of satisfaction of the patients after treatment received. For the statistical analysis the average values, median and standard deviation was obtained and by the use Kappa coefficient in agreement with Landis and Koch (1977), Kruskal Wallis Test and Spearman coefficient, with a 5% significance level adopted. Results: The unilateral cleft lip and palate accounted for 62.5% of cases. There was no statistically significant difference between the groups of examiners, was identified in all the cases aesthetically acceptable prosthesis, and the agreement of interjudges was considered moderate to substancial. For patients, the treatment was satisfactory in 65% of the cases, while22.5% considered acceptable. Conclusion: Most clinical cases was considered aesthetically acceptable prostheses with the dentures should be improved with respect to the curvature and size of incisal crowns. The absence of gingival papilla and its artificial replacement were observed in most clinical cases. Most patients considered satisfactory prosthesis in relation to aesthetics and also in relation to aesthetics of the smile, but do not consider acceptable in relation to aesthetic of the prosthesis, more studies are needed to achieved excellence in the treatment gives patients.
66

Análise fotoelástica das tensões geradas por diferentes planejamentos de próteses parciais fixas parafusadas sobre implantes cone morse / Photoelastic analyses of stress generated by different designs of screw-retained fixed partial denture on morse taper implants

Érica Miranda de Torres 01 July 2008 (has links)
A restauração protética deve receber e transmitir cargas funcionais aos implantes de forma controlada, a fim de minimizar a ocorrência de falhas mecânicas e biológicas. A concentração de tensões inadequadas na interface osso-implante pode provocar reabsorção óssea em torno dos implantes em níveis superiores aos considerados clinicamente aceitáveis. Não existe consenso na literatura quanto ao melhor planejamento protético para reabilitações parciais com múltiplos implantes adjacentes, a fim de minimizar as tensões geradas na interface osso-implante. A fotoelasticidade é uma técnica experimental para análise de tensões, bastante empregada devido à sua relativa simplicidade e confiabilidade quanto à correspondência clínica dos achados observados. O presente trabalho se propôs a avaliar, por meio de análise fotoelástica, o comportamento biomecânico de próteses parciais fixas parafusadas sobre implantes cone morse com coroas isoladas ou unidas, simulando a reabilitação de áreas posteriores com e sem a presença de elemento dental distal aos implantes, e ainda variando o tipo de material de recobrimento estético empregado na restauração protética (cerâmica ou resina), quando sobre estas próteses foram aplicadas diferentes tipos de cargas estáticas. Para tanto, foi confeccionado um modelo fotoelástico simulando um espaço protético intercalado, com ausência do segundo prémolar e primeiro molar, reabilitado por meio de quatro tipos de coroas parafusadas sobre dois implantes cone morse (Neodent) adjacentes: UC - coroas unidas com recobrimento estético em cerâmica; IC - coroas isoladas com recobrimento estético em cerâmica; UR - coroas unidas com recobrimento estético em resina; IR - coroas isoladas com recobrimento estético em resina. A adaptação marginal das coroas foi avaliada pela leitura dos desajustes verticais na interface coroa/pilar em microscópio ótico. Análise fotoelástica qualitativa foi realizada sob diferentes condições de aplicação de carga na superfície oslusal das coroas: oclusal distribuída (1kgf), puntiforme simultânea (1kgf), puntiforme alternada no molar e no pré-molar (0,5kgf). A primeira análise foi feita na presença de contato proximal efetivo entre as próteses e o dente a distal dos implantes. A segunda análise foi realizada após eliminar a coroa do dente distal no modelo fotoelástico. Registros fotográficos foram obtidos de cada situação de interesse para análise, a fim de facilitar a observação e comparação do padrão de distribuição das franjas isocromáticas em torno dos implantes. De acordo com os resultados obtidos pode-se concluir que a ferulização das coroas promoveu melhor distribuição de tensões em torno dos implantes. As restaurações metalocerâmicas resultaram em menor magnitude e concentração de tensões em torno dos implantes quando comparadas às restaurações metaloplásticas. A presença de um dente com ponto de contato efetivo na distal das coroas não modificou as tensões resultantes em torno dos implantes, mas este dente participou da distribuição de tensões para o modelo fotoelástico. A ausência de uma oclusão bem ajustada e distribuída sobre as restaurações protéticas pode provocar sobrecarga nos implantes. / Prosthetic restoration should suffer and apply functional loads over implants in a controlled way with the aim to reduce the occurrence of mechanical and biological failures. The concentration of inadequate stress on the implant-bone interface may cause bone resorption around implants at levels above those considered clinically acceptable. There is no consensus in the literature about the best prosthetic plan for partial rehabilitation with multiple adjacent implants, with the aim to reduce the stress generates over the implantbone interface. Photoelasticity is an experimental technique used to analyzes stress and is highly used due to its relative simplicity and reliability in terms of the clinical agreement of the findings. The purpose of the present study was to assess, using photoelastic analysis, the biomechanical behavior of screwretained fixed partial dentures on morse taper implants with individual or connected crowns, simulating the rehabilitation of posterior areas with or without the presence of a dental element distal to the implants. Furthermore, the analyses considered different esthetic materials used in prosthetic restorations (ceramic or resin), and different static loads were applied over the prostheses. To do this, a photoelastic model was fabricated simulating the missing of the second pre-molar and the first molar. The model was rehabilitated through four types of screw-retained crowns over two adjacent morse taper implants (Neodent): CC connected crowns with ceramic esthetic overlay; IC individual crowns with ceramic esthetic overlay; CR connected crowns with resin esthetic overlay; - IR - individual crowns with resin esthetic overlay. The crowns marginal fit was assessed by reading the vertical misfits on the crownabutment interface using an optic microscope. The qualitative photoelastic analysis was performed under the application of different loads on the crowns occlusal surface: distributed occlusal (1kgf), simultaneous punctiform (1kgf), alternate punctiform over the molar and pre-molar (0.5 kgf). The first analysis was done with an effective proximal contact between the prostheses and the distal tooth. The second analysis was performed after eliminating the crown of the distal tooth in the photoelastic model. Photoelastic records were obtained in each situation that was of any interest to the analysis, with the aim to make it easy to observe and compare the distribution standard of the isochromatic fringes around the implants. According to the obtained results, it is concluded that crown splint promoted better stress distribution around the implants. The metallo-ceramic restorations resulted in less magnitude and stress concentration around the implants compared to metaloplastic restorations. The presence of one tooth with an effective contact point on the crown distal did not change the resulting stress around the implants, but that tooth took part in the stress distribution for the photoelastic model. A bad distributed occlusion over the prosthetic restorations can cause overload on the implants.
67

Comportamento biomecânico de estruturas multicamadas em restaurações protéticas / Biomechanical behavior of multilayer structures in dental prosthetic

Costa, Anna Karina Figueiredo [UNESP] 28 January 2016 (has links)
Submitted by ANNA KARINA FIGUEIREDO COSTA null (karina_fcosta@yahoo.com.br) on 2016-04-21T11:28:44Z No. of bitstreams: 1 Anna Karina final 20 abril 2016.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-02T16:35:35Z (GMT) No. of bitstreams: 1 costa_akf_dr_sjc.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5) / Made available in DSpace on 2016-05-02T16:35:35Z (GMT). No. of bitstreams: 1 costa_akf_dr_sjc.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5) Previous issue date: 2016-01-28 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse trabalho foi identificar por meio da utilização de geometrias complexas (pela análise de elemento finito) e simplificadas, se novas tecnologias (sistema CAD/CAM) resultam em um comportamento biomecânico mais favorável na cerâmica de cobertura quando comparado à técnica de aplicação convencional (estratificação). Foram modelados três diferentes estruturas de prótese parcial fixa de três elementos com diferentes técnicas de fabricação: convencional, Rapid Layer (feldspática, cimento resinoso e zircônia) e CAD-on (dissilicato, material vítrio de baixa fusão e zircônia) a fim de analisar a distribuição tensão de tração gerada durante um ensaio mecânico pelo método por elementos finitos. Discos (cerâmica de cobertura e zircônia) foram unidos seguindo as três diferentes técnicas (convencional, Rapid Layer e CAD-on). Foram também confeccionadas próteses parciais fixas de 3 elementos pela técnica de multicamada seguindo as mesmas configurações dos modelos utilizados na análise por elementos finitos. Essas coroas foram cicladas durante 2x106 ciclos para analisar falhas na cerâmica de cobertura, como trincas, lascamento, delaminação e falha catastrófica. Os resultados mostraram que as coroas confeccionadas com cerâmica de dissilicato de lítio e material vítreo na interface infraestrutura/cerâmica de cobertura apresentaram menor concentração de tensão de tração quando comparadas aos modelos confeccionados pela técnica convencional, que demonstraram maior concentração de tensão de tração entre as camadas (cerâmica de cobertura, interface e infraestrutura). Para os discos, o acréscimo de material na interface cerâmica de cobertura e infraestrutura mostrou maior resistência à fratura biaxial e menor propagação da trinca entre as camadas de cerâmica. As coroas cicladas não apresentaram falhas como: trincas, lascamento, delaminação e catastrófica nos primeiros 500.000 ciclos. Porém, as próteses confeccionadas com cerâmica feldspática apresentaram trincas a partir de 1x106 ciclos, diferentemente das coroas confeccionadas na técnica Rapid Layer e CAD-on. As coroas confeccionadas pela técnica RL e CAD-on podem ser consideradas um sistema favorável por prevenir a propagação de trincas radiais em direção à superfície da restauração e melhorar a tenacidade à fratura do material. / The aim was to identify whether the CAD/CAM approach resulted in more favourable stressing patterns in the veneer-ceramic when compared with a conventionally sintered Y-TZP core/veneer-ceramic. Three different designs crowns of prosthesis with three elements and different manufacturing techniques were modeled: conventional technique, Rapid Layer (feldspathic ceramic, resin cement and zirconia) and CAD-on (disilicate, fusion glass ceramic and zirconia) techniques to analyze the distribution stress tensile generated during a mechanical test by the finite element method. Moreover, were made feldspathic ceramic discs, lithium disilicate discs and Y-TZP zirconia discs to analyze the influence of biaxial flexure stress of these three different techniques. These discs (veneer ceramic and zirconia ceramic) were joined following the three different techniques (conventional, Rapid Layer and CAD-on). They were also made FPDs 3 elements: following the same design of models used in finite element analysis. These crowns were cycled during 2x106 cycles to analyze failure at veneer ceramic, such as cracks, chipping, delamination and catastrophic failure. The results showed that the crowns made from ceramic lithium disilicate and low fusion glass ceramic at the interface veneer ceramic/infraestructure showed low concentration of tensile stress when compared to models made by the conventional technique, which showed a greater concentration of tensile stress between layers (veneer ceramic, interface and infrastructure). For the discs samples, the multilayer materials showed lower crack propagation between the ceramic layers. The cycled crowns showed no failure as cracks, chipping, delamination and catastrophic failure for the first 500,000 cycles. However, the prostheses made with feldspathic ceramic showed cracks from 1.106 cycles. The incorporation of functionally and aesthetically graded layers would be realisable, considerable research would be required before the feasibility of the conceptual approach could be accurately assessed. / FAPESP: 2012/11095-0
68

Efeitos do uso de próteses múltiplas implantossuportadas, unidas e isoladas, nas tensões geradas em áreas posteriores da mandíbula / Load transfer characteristics in the posterior region of the mandible of implant supported, splinted and non-splinted restorations

Rodrigo Tiossi 21 December 2010 (has links)
O comportamento biomecânico de próteses implantossuportadas foi analisado por fotoelasticidade e por correlação de imagens digitais (CID). Este trabalho estudou o comportamento biomecânico de próteses parciais fixas parafusadas sobre implantes, com coroas isoladas ou unidas, simulando a reabilitação de área posterior mandibular, com e sem a presença de elemento dental distal aos implantes. Devido às dificuldades em produzir estruturas múltiplas com assentamento passivo, alguns autores sugerem que implantes adjacentes sejam restaurados por próteses unitárias, minimizando os efeitos das tensões transferidas aos implantes. A análise fotoelástica é uma técnica experimental para análise de tensões, bastante empregada devido à sua relativa simplicidade e confiabilidade quanto à correspondência clínica dos achados observados. A análise por correlação de imagens digitais produz o mapeamento completo das tensões geradas na superfície do modelo analisado, possibilitando análises precisas. Não existe consenso na literatura quanto ao melhor planejamento protético para reabilitações parciais com múltiplos implantes adjacentes, a fim de minimizar as tensões geradas na interface osso-implante. O material de recobrimento estético empregado na restauração protética também foi analisado (cerâmica e resina). O modelo de estudo foi composto por um pré-molar em resina, dois implantes (Titamax GT - 4,0 x 11,0 mm - Neodent) substituindo o 2º pré-molar e o 1º molar, e um 2º molar em resina. Outro modelo foi produzido sem a presença do 2º molar. Os grupos analisados foram: UC - coroas unidas e recobertas por cerâmica; IC - coroas isoladas e recobertas por cerâmica; UR - coroas unidas e recobertas por resina; IR - coroas isoladas e recobertas por resina. O efeito do torque na fixação das estruturas foi avaliado por meio de análise fotoelástica. Análise fotoelástica qualitativa e quantitativa foi realizada após a aplicação de carga vertical puntiforme (50 N) na superfície oclusal da coroa substituindo o 1º molar. A análise por correlação de imagens também foi feita qualitativa e quantitativamente, com a carga aplicada na mesma posição que para a análise fotoelástica, mas com maior intensidade (250 N). Tensões na direção horizontal (&epsilon;xx) e de cisalhamento (&epsilon;xy) foram analisadas e comparadas pelo método CID. Os dois métodos para análise de tensões aplicados neste estudo foram satisfatórios e adequados para as comparações necessárias ao trabalho proposto. De acordo com os resultados obtidos, pode-se concluir que a esplintagem de coroas sobre múltiplos implantes adjacentes promoveu melhor distribuição de tensões em torno dos implantes e pelas estruturas de suporte, principalmente quando o contato proximal distal esteve ausente. As tensões totais no modelo não foram influenciadas pela presença do 2º molar, mas este dente participou da distribuição de tensões entre as estruturas. O material de recobrimento das coroas não foi significativo para as tensões transferidas ao modelo fotoelástico e para as tensões compressivas (&epsilon;xx). As tensões de cisalhamento (&epsilon;xy) foram influenciadas diretamente pela presença do 2º molar inferior e, com sua ausência, um material de recobrimento com baixo módulo de elasticidade (resina) foi significativo para minimizar estas tensões. / A photoelastic stress analysis and a digital image correlation (DIC) method were used to analyze the biomechanical behavior of implant supported prosthesis. This study compared the biomechanical behavior of screwed, splinted and non-splinted, implant supported fixed partial dentures, simulating the rehabilitation of a mandibular posterior region, with and without the presence of a second molar proximal contact. Since complete passivity is difficult to achieve when splinted restorations supported by multiple implants are used, some authors suggest individually restoring adjacent implants to allow for a passive fit in the resulting restorations, thus reducing the strains transferred to the implants. Photoelasticity is an experimental technique for stress analysis and has been constantly used due its simplicity, reliable results and correlation with clinical findings. The digital image correlation method is capable of providing a full-field surface strain measurement, allowing for an accurate analysis. The ideal restoration of a partially edentulous space remains controversial as to the best prosthetic design for a partial rehabilitation with multiple implants in order to minimize the strains transferred to the bone-implant interface. The influence of the veneering materials was also compared (porcelain and resin). An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants (Titamax GT - 4.0 x 11.0 mm - Neodent) replacing the second premolar and first molar. Another model was made without the presence of the second molar. Groups were: UC - porcelain-veneered splinted crowns; IC - porcelain-veneered non-splinted crowns; UR - resin-veneered splinted crowns; IR - resin-veneered non-splinted crowns. Strains transferred to the photoelastic model were analyzed after tightening the prosthetic screws. Qualitative and quantitative photoelastic stress analysis was performed after the application of a vertical load (50 N) on the occlusal surface of the crown replacing the first molar. The image correlation analysis was also performed qualitatively and quantitatively, with the load applied in the same position as for the photoelastic analysis, although with greater intensity (250 N). Strains in the horizontal direction (&epsilon;xx) and shear strains (&epsilon;xy) were analyzed and compared with the DIC method. Both methods for strain analysis used in this study performed satisfactory and are adequate for the comparisons proposed in this work. According to the results found, it can be concluded that splinting multiple adjacent implant supported crowns provided a better strain distribution around the implants and the supporting structures, especially when the distal proximal contact was absent. The total strains in the model were not influenced by the presence of a distal proximal contact, but the presence of the second molar optimized the strain distribution between the structures. The crowns veneering material was not significant for the strains transferred to the photoelastic model and for compressive strains (&epsilon;xx). Shear strains (&epsilon;xy) were influenced by the presence of the second molar, and when it was absent, the use of a veneering material with low elasticity modulus (resin) significantly reduced these tensions.
69

RESISTÊNCIA À FRATURA DE PILARES DE PRÓTESES FIXAS RESTAURADOS COM NÚCLEO DIRETO E INDIRETO EM MANDÍBULAS DE SUÍNOS / FRACTURE STRENGTH OF FIXED PARTIAL DENTURES ABUTMENTS RESTORED WITH DIRECT AND INDIRECT CORE IN SWINE JAW

Palma, Débora Chiele 09 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to compare the fracture strength of abutment teeth, under fixed partial denture (FPD), restored with direct and indirect core, to analyze the type of fracture and to verify its relation to the type of core used. A total of 15 bone blocks taken from the jaw of adult swine, with at least 1th and 3rd molars, that were the abutment teeth for the FPD. The specimens were divided into 3 experimental groups (GR): GR I - (control) dentine core, GR II - cast metallic core in non-precious Cu-Al alloy (NPG, Aalbadent, USA) and GR III - glass fiber post (White post DC, FGM, BRA) and composite resin (Opallis, FGM, BRA). The standardization of coronary core was performed by a matrix of acetate obtained from the preparation of the GR I. The cementation of intraradicular retainers was performed with dual self-adhesive resin cement (RelyX U100, 3MESPE, USA). Infrastructures for FPDs of four elements were waxed, from acetate matrix to standardize the size and shape, casted with non-precious Ni-Cr alloy (Wironia light, Wilcos, USA) and cemented with dual self-adhesive resin cement (RelyX U100, 3MESPE, USA). The bone blocks were embedded in acrylic resin and subjected to compression test by universal testing machine, until fracture. The fractures were classified as repairable (upper or to the bone level) or irreparable (beyond the bone level), after analysis by stereomicroscope and tomography computed. Tests Analysis of variance and Fisher's exact test (p<0.05) were applied for statistical analysis. For the variable fracture strength, there were no statistical differences among the cores tested (p = 0.113), both GR I and the GR III, 100% of the fractures were repairable and GR II, 80% of the fractures were irreparable. There is evidence of association between fracture type and the core type used (p = 0.011). It was possible to conclude that: 1. The type of core used did not influence the fracture strength of the abutment teeth. 2. The type of fracture occurred in the abutments was predominantly repairable, when restored with direct core, and irreparable when restored with indirect core. 3. There is association between core type and the fracture type occurred. / O objetivo deste estudo foi comparar a resistência à fratura de pilares de próteses parciais fixas (PPFS) restaurados com núcleo em dentina, com pino de fibra de vidro e resina composta e com núcleo metálico fundido; analisar o tipo de fratura (reparável ou irreparável) e verificar a sua relação com o tipo de núcleo utilizado. Foram utilizados 15 blocos ósseos extraídos da mandíbula de suínos adultos, com 1º, 2º e 3º molares, que constituíram os pilares para a PPF. Os espécimes foram divididos em 3 grupos (GR) experimentais: GR I - (controle) núcleo em dentina, GR II - núcleo metálico fundido (NMF) em liga não preciosa Cu-Al (NPG, Aalbadent, USA) e GR III - pino de fibra de vidro - PFV (White post DC, FGM, BRA) e resina composta - RC (Opallis, FGM, BRA). A padronização coronária dos núcleos foi realizada através de uma matriz de acetato obtida a partir do preparo do GR I. A cimentação dos retentores intrarradiculares foi realizada com cimento resinoso autoadesivo dual (Relyx U100, 3MESPE, USA). Infraestruturas para PPFs de 4 elementos foram enceradas, a partir de uma matriz de acetato para padronização de dimensão e formato, fundidas em liga não preciosa Ni-Cr (Wironia light, Wilcos, BRA) e cimentadas com cimento resinoso autoadesivo dual (Relyx U100, 3MESPE, USA). Posteriormente, os blocos ósseos foram embutidos em resina acrílica autopolimerizável e submetidos ao ensaio de compressão em máquina de ensaio universal até a fratura. As fraturas foram classificadas como reparáveis (acima ou ao nível da crista óssea) ou irreparáveis (abaixo da crista óssea), após análise por estereomicroscópio e tomografias computadorizadas. Foram aplicados os testes Análise de Variância e Teste Exato de Fisher (p<0,05) para análise estatística. Para a variável resistência à fratura, não foi observada diferença estatística entre os núcleos testados (p=0,113), tanto no GR I quanto no GR III, 100% das fraturas foram reparáveis e no GR II, 80% das fraturas foram irreparáveis. Foi verificada associação entre tipo de fratura e o tipo de núcleo utilizado (p=0,011). Concluiu-se que o tipo de núcleo utilizado não influencia a resistência à fratura dos dentes pilares, entretanto influencia o tipo de fratura gerado.
70

Influência de tratamentos superficiais e termociclagem na resistência da união resina/metal /

Almilhatti, Hercules Jorge. January 2004 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Gelson Luis Adabo / Banca: Carlos Eduardo Vergani / Banca: Maria da Glória Chiarello de Mattos / Banca: Ricardo Faria Ribeiro / Resumo: Este estudo teve como objetivo avaliar a efetividade de quatro condicionadores de metal (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL e Siloc, S) aplicados sobre diferentes superfícies das ligas de Ni-Cr, Co-Cr e do metal Ti Cp. Após o polimento metalográfico e jateamento com Al2O3, foram obtidos três grupos experimentais para cada metal : Grupo polimento (P) - controle; Grupo (J50), jateado com Al2O3 de 250 um. A esses grupos foram aplicados os condicionadores e as resinas opaca e de revestimento estético (Artglass). Decorridos 24 horas de armazenamento em água a 37ºC, cada grupo foi dividido em dois grupos e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min.), um antes e outro após 500 ciclos térmicos (60ºC e 4ºC). As superfícies fraturadas foram analisadas e o padrão de falhas determinado. Adicionalmente foram feitas análises de MEV e EDS. Seguem os resultados para cada metal: Liga de Ni-Cr: para os Grupos P e J50, não foram observadas diferenças (p>0,05) nos valores médios de tensão de cisalhamento entre os condicionadores OP e TL e entre MPP e S, sendo maiores as médias dos dois primeiros. Não foram encontradas diferenças (p>0,05) entre as médias de tensão para os condicionadores do Grupo J250. No entanto, esses valores foram superiores aos do Grupo J50. Após a termociclagem, as médias para os condicionadores OP, S e TL não apresentaram aumento significante (p>0,05), enquanto a média para o MPP aumentou (p<0,05). Liga de Co-Cr, para o Grupo P, não foram observadas diferenças (p>0,05) nos valores médios de tensão entre os condicionadores OP e TL e entre MPP e S, sendo superiores as médias dos dois primeiros. As médias de tensão para o Grupo J250 foram estatisticamente maiores às do Grupo J50, ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of the study was to evaluated the effect of three adhesive primers (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL) and a bonding system (Siloc, S) on the shear bond strength between a prosthetic composite material (Artglass) to Ni-Cr alloy (Wiron 99), Co-Cr alloy (Wironit), and CP Ti (Tritan). Disk patterns were cast of the 3 alloys. All the disk surfaces were abraded with No. 80, 320, and 600 SiC paper, respectively and three different surface treatment were applied: No. 600 SiC polishing, P; 50 mm Al2O3 sandblasting, S50; 250 mm Al2O3 sandblasting, S250. The composites (Artglass opaque and dentin) were applied using a cylindrical stainless steel split according to manufacturer's instructions then light polymerized. Specimens without primer and bonding system were also prepared as control. The specimens were stored in water a 37oC for 24 h and then shear bond strengths were determined both before and after immersed alternately in water baths at 4oC and 60oC for 15 seconds each for up to 500 thermal cycles before shear mode testing at a crosshead speed of 0.5 mm/min. Data were statistically analyzed using 3-way ANOVA and 1-way ANOVA, followed by Tukey multiple range intervals calculated at the 0.05 significance level. Fractured interfaces were analyzed by use of light microscopy and SEM. Results: Ni-Cr alloy: The bond strength of the P-OP/J50-OP group and P-TL/J50- TL group were statistically comparable (p>0,05) and exhibited greater strength than the P-MPP/J50-MPP group and P-S/J50-S (p<0,05). No significant differences were found among the four conditioners for J250 group (p>0,05), and these group showed the greater strength than the J50 group (p<0,05). After thermocycling, no significant differences (p>0,05) were found among the three primers (OP, S, TL) and the bond strength of MPP increased...(Complete abstract, click electronic access below) / Doutor

Page generated in 0.0491 seconds