• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 140
  • 2
  • 1
  • Tagged with
  • 146
  • 86
  • 22
  • 18
  • 16
  • 12
  • 12
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Determinação da taxa de desintegração e das probabilidades de emissão gama por decaimento do I-123 / Disintegration rate and gamma ray emission probability per decay measurement of 123I

Gishitomi, Karoline Cianci 23 May 2012 (has links)
Neste trabalho foi desenvolvido o método de padronização do 123I em sistema de coincidências 4π(X,A)-γ. O 123I foi produzido no cíclotron Cyclone-30 do IPEN CNEN/SP, por meio da irradiação do 124Xe. O 123I decai com uma meia vida de 13,22 horas pelo processo de captura eletrônica seguido da emissão de radiação gama. Foi aplicada a técnica de extrapolação linear da eficiência para determinação da atividade e para determinação do coeficiente de conversão interna total do nível de 159 keV, obtido a partir da inclinação da curva de extrapolação. A curva de extrapolação experimental foi comparada com a simulação de Monte Carlo, executada pelo código ESQUEMA. As fontes radioativas foram também medidas em um sistema de espectrometria de HPGe, a fim de determinar a probabilidade de emissão gama por decaimento para várias transições gama. Todas as incertezas envolvidas e suas correlações foram analisadas aplicando a metodologia de matriz de covariância e os parâmetros medidos foram comparados com os da literatura. / This paper describes the development of the 123I standardization method in a 4π(X, A)-γ coincidence system. The 123I was produced in the ciclotron-30 of IPEN CNEN / SP through the irradiation of the 124Xe. The 123I decays with a half-life of 13.22 hours by electron capture process followed by emission of gamma radiation. The experimental extrapolation curve was determined and compared to Monte Carlo simulation, performed by code ESQUEMA. From the slope of the experimental curve, the total conversion coefficient for the 159 keV total gamma transition, 159, was determined. All radioactive sources were also measured in an HPGe spectrometry system, in order to determine the gamma-ray emission probability per decay for several gamma transitions. All uncertainties involved and their correlations were analyzed applying the covariance matrix methodology and the measured parameters were compared with those from the literature.
42

Medida absoluta da atividade e determinação da probalidade de emissão gama por decaimento do 177 Lu / Absolute activity measurement and determination of gamma-ray emission probability per decay of 177Lu

Silva, Fabricio Fernandes Vaz da 17 February 2011 (has links)
O presente trabalho teve como objetivo a padronização em atividade do radionuclídeo 177Lu, um importante radiofármaco utilizado no tratamento de câncer neuroendócrino. Este radionuclídeo se desintegra por emissão beta acompanhada de várias emissões gama simultâneas, o que tornou possível a aplicação do método de coincidência 4πβ-γ. Para a detecção da radiação beta, foi utilizado um detector proporcional (PC), com geometria 4π e dois cintiladores de NaI(Tl) para a detecção da radiação gama. Os sinais gerados nos detectores passaram por amplificadores, discriminadores e módulos atrasadores, para serem enviados a um analisador multicanal. Para este experimento, foi utilizado um sistema de coincidências que aplica um módulo TAC (Time to Amplitude Converter), o qual converte diferença de tempo em amplitude de pulso. Para obter-se a variação na eficiência beta, foram acrescentados absorvedores de Collodion nas partes superior e inferior da fonte radioativa. Desta forma, foi possível extrapolar o valor para eficiência beta igual a 100%, obtendo assim a atividade da fonte radioativa. A curva de extrapolação experimental foi comparada com a previsão teórica, obtida por meio do método de Monte Carlo. Além da padronização em atividade do 177Lu, também foram determinadas as suas probabilidades de emissão gama por decaimento para cada uma das principais transições gama, por meio de um espectrômetro de HPGe, previamente calibrado. / The present work aimed the activity standardization of radionuclide 177Lu, an important radioisotope used for treatment of neuroendocrine cancer. This radionuclide disintegrates by beta decay followed by several simultaneous gamma-ray emissions, which made possible the application of the 4πβ-γ coincidence method. For the detection of beta radiation in 4π geometry a proportional detector (PC) was used, and for gamma radiation detection a pair of NaI(Tl) scintillators was used. The signals generated by the detectors passed through amplifiers, discriminators and delay modules, and were sent to a multichannel analyzer. For the present experiment, the system includes a TAC (Time to Amplitude Converter) module which converts the time difference in pulse amplitude. To obtain the variation in beta efficiency, Collodion absorbers at the top and bottom of the radioactive source were applied. In this way, it was possible to extrapolate the beta efficiency value to 100%, thereby obtaining the radioactive source activity. The extrapolated experimental curve was compared with the theoretical prediction, obtained by means of the Monte Carlo method. Besides the activity standardization of 177Lu, its gamma-ray emission probabilities per decay for the main gamma transitions were also determined by means of an HPGe spectrometer, previously calibrated.
43

Coordenação modular: acepções contemporâneas / Modular coordination: contemporary acceptations

Marina Rosa Crespo 23 May 2017 (has links)
A coordenação modular é um sistema para ordenação relativa de dimensões, espaços e componentes construtivos. Sua aplicação tem manifestações remotas por princípios que controlam a composição e fixam escalas convenientes para as partes e o todo, todavia foi a produção seriada industrial que determinou o papel que a disciplina teria no século XX. No Brasil, seu desenvolvimento aconteceu entre as décadas de 1950 e 1970, quando foi determinada a formatação fundamental da disciplina. Identifica-se a partir da década de 1980 um intervalo nas discussões específicas que durou até a virada do século, quando foi recuperado o interesse pela área. É consenso entre os autores que ainda não houve no Brasil sucesso na implantação de modelos abrangentes da coordenação modular, mas faltam análises atualizadas. O objetivo da dissertação - examinar o desenvolvimento da disciplina no Brasil após 1986 - está fundamentado em indícios de que as discussões recentes não se aprofundam em temas atuais e de que há um enfraquecimento de uma visão integrada do problema. As principais conclusões indicam que o desenvolvimento da construção civil vem sendo acompanhado do afastamento da arquitetura de etapas da produção, o que afeta o exercício da coordenação modular e que o programa habitacional e as ações políticas de financiamento foram determinantes para a retomada das pesquisas. Entretanto, há ecos dos modelos estabelecidos pelo setor privado, com ênfase à racionalização e à aplicação de componentes industriais. Diante disso, destaca-se que a coordenação modular, como campo da coordenação dimensional, está ligada às necessidades humanas. / Modular coordination is a system for relative ordering of dimensions, spaces, and building components. Its application presents remote manifestations through principles that control the design and set suitable scales for the parts and the whole. Nevertheless, the industrial mass production defined the role that the subject would play during the 20th century. In Brazil, its development took place between the 1960s and the 1970s; period that several authors consider decisive in what regards the subject\'s fundamental formatting. From the 1980s on, the specific debates about the matter went through a gap that lasted until the turn of the century when the interest in the field resurfaced. It is consensual among authors that Brazil still has not been successful to implement comprehensive modular coordination standards, but there is a lack of up-to-date analysis as well. The objective of the dissertation - to examine the discipline\'s development in Brazil after 1986 - is based on indications that recent discussions are leaving aside current issues and that there is a weakening of an integrated view of the matter. The main conclusions indicate that a dissociation between architecture and construction has accompanied the building industry\'s development, which affects the application of modular coordination. Moreover, the housing program and the research funding were decisive for the resumption of the field; nonetheless, there are echoes from the models established by the private sector, with emphasis on the rationalization and application of industrial components. In this context, it should be noted that modular coordination, as a field of dimensional coordination, is linked to human needs.
44

Medida absoluta da atividade e determinação da probalidade de emissão gama por decaimento do 177 Lu / Absolute activity measurement and determination of gamma-ray emission probability per decay of 177Lu

Fabricio Fernandes Vaz da Silva 17 February 2011 (has links)
O presente trabalho teve como objetivo a padronização em atividade do radionuclídeo 177Lu, um importante radiofármaco utilizado no tratamento de câncer neuroendócrino. Este radionuclídeo se desintegra por emissão beta acompanhada de várias emissões gama simultâneas, o que tornou possível a aplicação do método de coincidência 4πβ-γ. Para a detecção da radiação beta, foi utilizado um detector proporcional (PC), com geometria 4π e dois cintiladores de NaI(Tl) para a detecção da radiação gama. Os sinais gerados nos detectores passaram por amplificadores, discriminadores e módulos atrasadores, para serem enviados a um analisador multicanal. Para este experimento, foi utilizado um sistema de coincidências que aplica um módulo TAC (Time to Amplitude Converter), o qual converte diferença de tempo em amplitude de pulso. Para obter-se a variação na eficiência beta, foram acrescentados absorvedores de Collodion nas partes superior e inferior da fonte radioativa. Desta forma, foi possível extrapolar o valor para eficiência beta igual a 100%, obtendo assim a atividade da fonte radioativa. A curva de extrapolação experimental foi comparada com a previsão teórica, obtida por meio do método de Monte Carlo. Além da padronização em atividade do 177Lu, também foram determinadas as suas probabilidades de emissão gama por decaimento para cada uma das principais transições gama, por meio de um espectrômetro de HPGe, previamente calibrado. / The present work aimed the activity standardization of radionuclide 177Lu, an important radioisotope used for treatment of neuroendocrine cancer. This radionuclide disintegrates by beta decay followed by several simultaneous gamma-ray emissions, which made possible the application of the 4πβ-γ coincidence method. For the detection of beta radiation in 4π geometry a proportional detector (PC) was used, and for gamma radiation detection a pair of NaI(Tl) scintillators was used. The signals generated by the detectors passed through amplifiers, discriminators and delay modules, and were sent to a multichannel analyzer. For the present experiment, the system includes a TAC (Time to Amplitude Converter) module which converts the time difference in pulse amplitude. To obtain the variation in beta efficiency, Collodion absorbers at the top and bottom of the radioactive source were applied. In this way, it was possible to extrapolate the beta efficiency value to 100%, thereby obtaining the radioactive source activity. The extrapolated experimental curve was compared with the theoretical prediction, obtained by means of the Monte Carlo method. Besides the activity standardization of 177Lu, its gamma-ray emission probabilities per decay for the main gamma transitions were also determined by means of an HPGe spectrometer, previously calibrated.
45

Determinação da taxa de desintegração e das probabilidades de emissão gama por decaimento do I-123 / Disintegration rate and gamma ray emission probability per decay measurement of 123I

Karoline Cianci Gishitomi 23 May 2012 (has links)
Neste trabalho foi desenvolvido o método de padronização do 123I em sistema de coincidências 4π(X,A)-γ. O 123I foi produzido no cíclotron Cyclone-30 do IPEN CNEN/SP, por meio da irradiação do 124Xe. O 123I decai com uma meia vida de 13,22 horas pelo processo de captura eletrônica seguido da emissão de radiação gama. Foi aplicada a técnica de extrapolação linear da eficiência para determinação da atividade e para determinação do coeficiente de conversão interna total do nível de 159 keV, obtido a partir da inclinação da curva de extrapolação. A curva de extrapolação experimental foi comparada com a simulação de Monte Carlo, executada pelo código ESQUEMA. As fontes radioativas foram também medidas em um sistema de espectrometria de HPGe, a fim de determinar a probabilidade de emissão gama por decaimento para várias transições gama. Todas as incertezas envolvidas e suas correlações foram analisadas aplicando a metodologia de matriz de covariância e os parâmetros medidos foram comparados com os da literatura. / This paper describes the development of the 123I standardization method in a 4π(X, A)-γ coincidence system. The 123I was produced in the ciclotron-30 of IPEN CNEN / SP through the irradiation of the 124Xe. The 123I decays with a half-life of 13.22 hours by electron capture process followed by emission of gamma radiation. The experimental extrapolation curve was determined and compared to Monte Carlo simulation, performed by code ESQUEMA. From the slope of the experimental curve, the total conversion coefficient for the 159 keV total gamma transition, 159, was determined. All radioactive sources were also measured in an HPGe spectrometry system, in order to determine the gamma-ray emission probability per decay for several gamma transitions. All uncertainties involved and their correlations were analyzed applying the covariance matrix methodology and the measured parameters were compared with those from the literature.
46

Determinação da taxa de desintegração dos emissores beta puros P-32 e Sr-90/Y-90 em sistema de cintilação líquida / Determination of desintegration rate of the beta pure emitters 32P and 90Sr 90Y in liquid scintillation system

Caio Pinheiros Marques 09 August 2017 (has links)
No presente trabalho, foram padronizados os radionuclídeos emissores beta puros 32P e 90Sr 90Y. O primeiro foi medido nos sistemas comerciais de cintilação líquida TRICARB 2100 e HIDEX 300SL, que utilizam, respectivamente, dois e três tubos fotomultiplicadores. A análise dos dados adquiridos pelo primeiro e segundo sistemas foi realizada pela aplicação dos métodos CIEMAT/NIST e TDCR, respectivamente. Para padronização da solução de 32P, foi também utilizado o sistema 4πβ empregando-se a técnica de autoabsorção. A solução de 90Sr 90Y foi padronizada no sistema de cintilação líquida, HIDEX 300SL, pelo método TDCR, e pela técnica do traçador, no sistema de coincidência 4πβ-γ o qual é composto por um contador proporcional à gás fluente, acoplado a dois cristais cintiladores de NaI(Tl). A taxa de desintegração foi determinada pela técnica de extrapolação, por meio de absorvedores externos. Para aplicação da técnica do traçador, foi utilizada uma solução de 60Co, emissor beta-gama previamente padronizado no sistema de coincidências. Foi realizada, também, uma simulação dos processos de detecção neste sistema por meio do programa ESQUEMA, que, pela simulação de Monte Carlo, prediz a curva de extrapolação da eficiência. Os resultados obtidos para o 32P nos sistemas utilizados apresentaram um bom acordo, dentro das incertezas experimentais, bem como os obtidos para o 90Sr 90Y, em sistema de cintilação e sistema de coincidência, apresentando bom acordo, dentro das incertezas experimentais. O resultado obtido pela técnica de Monte Carlo apresentou boa concordância com o valor obtido com o sistema de coincidência. Os resultados indicam a qualidade e boa precisão dos sistemas de detecção utilizados neste trabalho, quando empregados para fins metrológicos. / In the present work, pure beta emitters radionuclides 32P and 90Sr - 90Y were standardized. The first one was measured in commercial liquid scintillation systems TRICARB 2100 and HIDEX 300SL, which use, respectively, two and three photomultiplier tubes. The analysis of the data acquired by the first and second systems was performed using the CIEMAT / NIST and TDCR methods, respectively. For standardization of the 32P solution, the 4πβ system was also used, using the self-absorption technique. The 90Sr - 90Y solution was standardized in the liquid scintillation system, HIDEX 300SL, by the TDCR method, and by the tracer technique, in the coincidence system 4πβ-γ which is composed by a proportional counter to the flowing gas, coupled to two NaI(Tl) scintillation crystals. The rate of disintegration was determined by the extrapolation technique, by means of external absorbers. For the application of the tracer technique, a 60Co solution, a beta-gamma emitter previously standardized in the coincidence system, was used. It was also performed a simulation of the detection processes in this system through the program ESQUEMA, which, by Monte Carlo simulation, predicts the efficiency extrapolation curve. The results obtained for the 32P in the systems used presented a good agreement, within the experimental uncertainties, as well as those obtained for the 90Sr - 90Y, in scintillation system and coincidence system, showing good agreement, within the experimental uncertainties. The result obtained by the Monte Carlo technique showed good agreement with the value obtained with the coincidence system. The results indicate the quality and good accuracy of the detection systems used in this work, when used for metrological purposes.
47

Estudo de padronização de extratos de folhas da caramboleira (Averrhoa carambola L.) na pesquisa e desenvolvimento de medicamentos antimicrobianos / Study of standardization of leaf extracts of caramboleira (Averrhoa carambola L.) in the research and development of antimicrobial drugs

Val, Érico Brito 29 August 2014 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-06-13T20:47:42Z No. of bitstreams: 1 EricoBritoVal.pdf: 419073 bytes, checksum: 939060a3ae4b2d788cc53dfc2b7e31e5 (MD5) / Made available in DSpace on 2017-06-13T20:47:42Z (GMT). No. of bitstreams: 1 EricoBritoVal.pdf: 419073 bytes, checksum: 939060a3ae4b2d788cc53dfc2b7e31e5 (MD5) Previous issue date: 2014-08-29 / The pharmaceutical industry invests millions of dollars on research of new pharmacs with antimicrobial activity, that can be used to develop new medicines, highlighting the ones from natural sources. To produce any kind of medicine is important to assure the quality, efectiveness and safe and in this process the raw material should be analyzed. The genus Averrhoa (Oxalidaceae) has two species of economic interest: A. bilimbi (cucumber tree) and A. carambola (starfruit). They are plants that grown in Brazil and probable natives from Asia, both have usages in the food industry, pharmaceutical potential and have many traditional uses against various pathologies. This dissertation was divided in two parts. The first part consists of a literature review covering botanical, economic, chemical, pharmacological and toxicity aspects of A. carambola and A. bilimbi, where it was observed that the majority of the studies is about A. carambola, which has over 170 compounds identified, mainly phenolic glycosides. Both plants have pharmacological studies with antimicrobial, antioxidant, cytotoxic, hypoglycemic, antitumor actions. Most studies were performed with hydroalcoholic and methanolic extracts, with some activity relating to isolated compounds. Further studies on chemical composition and biological activities of these species are needed, especially A. bilimbi, and of their biological properties. The data can support the future studies with these species. In the second part we aimed to provide data for the standardization of extracts from A. carambola L., from chemical and biological assays of antimicrobial activity, to contribute to produce safe medicines. The antimicrobial activity was performed with bacteria, using microdilution methods and difusion in agar well technique. Sample leaves of A. carambola was collected in the region of Matões in Maranhão state. The dried and powdered leaves were used to obtain hydroalcoholic extracts from factorial design, with variables as different extractive methods (maceration, percolation and Soxhlet apparatus) and hydromodules (1: 8, 1:12 and 1:16). The extracts were evaluated, qualitatively and semi-quantitatively chemical constituents, total polyphenol content, flavonoid content and antimicrobial activity against S. aureus, E. coli, P. aeruginosa and K. pneumoniae. The extracts presented differences in color, quantitative variations in the chemical constituents and content of flavonoids and phenolic compounds. It was also observed differences in antimicrobial activity of the extracts tested in the two methods. The extract obtained, by percolation and using hydromodule ratio of 1: 8 showed the more expressive results for chemical composition and biological activity, thereby confirming that the examined variables influenced the composition of the extracts and consequently in the results. We have showed the best methods for this species to get an extract with antimicrobial activity. / A indústria farmacêutica investe milhões de dólares na pesquisa de novos fármacos com ação antimicrobiana que possam ser empregados para o desenvolvimento de novos medicamentos destacando-se aqueles oriundos de fontes naturais. A produção de medicamentos exige o cumprimento da garantia de parâmetros de qualidade, segurança e eficácia, sendo imprescindível a avaliação de suas matérias primas. O gênero Averrhoa (Oxalidaceae) apresenta duas espécies de interesse econômico: A. bilimbi (limão-de-caiena) e A. carambola (caramboleira). São plantas cultivadas no Brasil e de provável origem asiática, ambas têm uso na indústria alimentícia, potencial farmacêutico e diversos usos tradicionais contra variadas patologias. Esta dissertação foi dividida em duas partes. A primeira parte consiste de revisão da literatura abrangendo aspectos botânicos, econômicos, químicos, farmacológicos e de toxicicidade de A. carambola e A. bilimbi, onde se pode observar que a maioria dos estudos são sobre A. carambola, que tem mais de 170 compostos identificados e com predominância de glicosídeos fenólicos. Ambas as plantas apresentam estudos farmacológicos, com ações antimicrobiana, antioxidante, citotóxica, hipoglicêmica, antitumoral comprovadas. A maioria dos estudos se deu com extratos hidroalcóolicos e metanólicos, com alguns relacionando atividade a compostos isolados. Há ainda necessidade de mais estudos sobre a composição química dessas plantas, especialmente de A. bilimbi, e de suas propriedades biológicas. Os dados contribuem para orientar futuros estudos com essas espécies que representam fontes de fármacos para a indústria farmacêutica. Na segunda parte, foi realizada a a padronização de extratos de A. carambola L., a partir de ensaios químicos e biológicos de atividade antimicrobiana, visando contribuir com o desenvolvimento de medicamentos eficazes. A ação antimicrobiana foi realizada frente a bactérias utilizando os métodos de microdiluição e difusão em ágar, técnica do poço. Amostra de folhas de A. carambola foi coletada na região de Matões no estado do Maranhão. As folhas secas e moídas foram submetidas à procedimentos para a obtenção de extratos hidroalcoólicos a partir de planejamento fatorial, tendo como variáveis: métodos extrativos (maceração, percolação e aparelho de Soxhlet) e relações de hidromódulos (1:8, 1:12 e 1:16). Os extratos foram avaliados quanto ao rendimento, constituintes químicos qualitativa e semi-quantitativamente, teor de polifenóis totais, teor de flavonóides e atividade antimicrobiana contra S. aureus, E. coli, P. aeruginosa e K. pneumoniae. Os extratos apresentaram diferenças na cor, variações quantitativas dos constituintes químicos e no teor de flavonoides e polifenóis totais. Foi observado também diferenças na atividade antimicrobiana dos extratos nos dois métodos testados. A análise indicou que o extrato de percolação 1:8 apresentou melhores resultados tanto na composição química, quanto na ação biológica, dessa forma confirmando que as variáveis apreciadas influíram na composição dos extratos obtidos e consequentemente nos resultados encontrados, sendo indicado o melhor método para obtenção de extrato da referida espécie com atividade antimicrobiana.
48

Padronização de extrativos bioativos e identificação de Jacarada decurrens Cham / Standardization of extract bioactive and indentification of compounds Jacaranda decurrens Cham.

MENEZES, Valéria de Jesus Menezes de 02 July 2013 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-09-05T18:43:06Z No. of bitstreams: 1 ValeriaMenezes.pdf: 1804629 bytes, checksum: cc847492cb67f3f0795ca116f5663006 (MD5) / Made available in DSpace on 2017-09-05T18:43:06Z (GMT). No. of bitstreams: 1 ValeriaMenezes.pdf: 1804629 bytes, checksum: cc847492cb67f3f0795ca116f5663006 (MD5) Previous issue date: 2013-07-02 / Jacaranda decurrens Cham. (Bignoniaceae) is a plant native to the Cerrado, popularly known as carobinha, carob or carob-of-field. Biological studies have shown giardicidal activity, antibacterial, antifungal, cytotoxic and larvicidal, being referred to the popular use in combating diarrhea, amebiasis, giardiasis, inflammations, gynecological infections, and skin disorders such as purifying the blood, indicating the presence of phenolic compounds, triterpenes and iridoid glycosides. The present study aimed to standardize extractives of leaves of Jacaranda decurrens giardicidal antioxidant potential and proven in previous studies, as parameters of quality certification. The leaves of this species were collected in São Raimundo Mangabeiras, state of Maranhão, Brazil and submitted to different extractive processes: maceration, percolation and Soxhlet with ethanol 70% (compared hydromodule 1:8, 1:10 and 1:12). Partition was held liquid / liquid leachate 1:10 hexane, dichloromethane and ethyl acetate to obtain the fractions. The extracts and fractions were subjected to phytochemical approach; levels of polyphenols were determined using the Folin Ciocalteau, total flavonoids with aluminum chloride, the antioxidant activity was performed by DPPH and evaluation giardicidal activity "in vitro" cytotoxicity by colorimetric method direct and indirect emoregando axenic strains of Giardia lamblia strain Portland-1 (ATCC30888). The profiles of the extractives were obtained by spectrometry UV / Vis, HPLC / UV / Vis and LC / MS. The results showed the presence of phenolic substances, and lack of triterpenoid steroids and alkaloids. The content of total polyphenols in the extracts and fractions ranged from 13.10 to 80.41% and flavonoids, 1.74 to 5.15%. The extracts and fractions showed antioxidant activities between EC50 ranges from 26.39 to 339.73 mg / mL. Extracts (M110, P108 and S112) were assessed giardicidal activity showed inhibitory activity against trophozoites of Giardia lamblia, and the values found between 17.10 to 18.92 ug / ml. The analysis of UV spectra showed similarities with maximum absorptions between 230 nm to 300 nm, indicating the presence of flavonoids. Analyzing the chromatograms, attributed to the percolation method in respect of 1:10 for the best extraction Jacaranda decurrens. Chromatogram obtained by HPLC / UV / Vis at a wavelength of 254 nm, it was found that the hexane fraction there was a peak coincident with the pattern of oleanolic acid with the same retention time (108.403), suggesting that this acid is one the chemical constituents of the plant. With mass spectrometry, we identified rutin, quercetin-pentosídeo-hexosídeo, quercetin-3-β-glucoside, arjunolic acid and acid-2α hidroxioleanólico. We conclude that the triterpenes (oleanolic acid) and flavonoids are likely responsible for giardicidal and antioxidant action. / Jacaranda decurrens Cham. (Bignoniaceae) é uma planta endêmica do Cerrado, conhecida como carobinha, caroba ou caroba-do-campo. A espécie é empregada popularmente no tratamento de amebíase, giardíase, inflamações, infecções ginecológicas, afecções cutâneas, no combate a diarreia e como depurativa do sangue, sendo comprovadas as ações giardicida, bactericida, antifúngica, citotóxica e larvicida, com a presença de compostos fenólicos, triterpenos e iridoides glicosilados. O presente trabalho teve como objetivo padronizar extrativos de folhas de Jacaranda decurrens com potencial giardicida e antioxidante, como parâmetros de certificação de qualidade. As folhas da espécie foram coletadas no município de São Raimundo das Mangabeiras, estado do Maranhão, Brasil e submetidas a diferentes processos extrativos: maceração, percolação e Soxhlet com etanol 70% (relação hidromódulo 1:8, 1:10 e 1:12). Foi realizada partição líquido/líquido do percolado 1:10 em hexano, diclorometano e acetato de etila para a obtenção das frações. Os extratos e frações foram submetidos à abordagem fitoquímica; os teores de polifenois foram determinados com reagente de Folin Ciocalteau; os flavonoides totais com cloreto de alumínio; a atividade antioxidante foi realizada pelo método DPPH e a avaliação da atividade giardicida ―in vitro‖ de citotoxicidade pelo método colorimétrico direto e indireto, emoregando cepas axênicas de Giardia lamblia, linhagem Portland-1 (ATCC30888). Os perfis dos extrativos foram obtidos por espectrometria de UV/Vis, CLAE/UV/Vis e LC/MS. Os resultados demonstraram presença de substâncias fenólicas, triterpênicas e ausência de cumarinas, esteroides e alcaloides. Os teores de polifenóis totais nos extratos e frações variaram de 13,10 a 80,41% e os de flavonoides, 1,74 a 5,15%. Os extratos e frações apresentaram atividades antioxidantes entre os intervalos de CE50 26,39 a 339,73 μg/mL. Os extratos (M110, P108 e S112) submetidos à avaliação da atividade giardicida demonstraram atividade inibitória sobre os trofozoítos de Giardia lamblia, sendo os valores encontrados entre 17,10 a 18,92 μg/ml. As análises dos espectros de UV demonstraram semelhanças com absorções máximas entre 230 a 300 nm, indicando a presença de flavonoides. Analisando os cromatogramas, atribuiu-se ao método de Percolação na relação de 1:10 o melhor extrativo para Jacaranda decurrens. Pelo cromatograma obtido por CLAE/UV/Vis no comprimento de onda de 254 nm, identificou-se que na fração hexânica houve um pico coincidente com o padrão do ácido oleanólico com o mesmo tempo de retenção (108.403), sugerindo que esse ácido seja um dos constituintes químicos da planta. Com o espectrômetro de massas, identificou-se ácido cafeoil, rutina,quercetina-pentosídeo-hexosídeo, quercetina-3-β-glicosídeo, ácido arjunólico e ácido 2α-hidroxioleanólico. Concluímos que os triterpenos (ácido oleanólico) e os flavonoides são os prováveis responsáveis pela ação giardicida e antioxidante.
49

Proposição de um método para implantação de um programa de padronização de componentes

Baccin, Bruno Miguel 13 January 2017 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2017-03-17T13:13:33Z No. of bitstreams: 1 Bruno Miguel Baccin_.pdf: 1986903 bytes, checksum: 534be108ef52eefbf7da278cfe86170a (MD5) / Made available in DSpace on 2017-03-17T13:13:33Z (GMT). No. of bitstreams: 1 Bruno Miguel Baccin_.pdf: 1986903 bytes, checksum: 534be108ef52eefbf7da278cfe86170a (MD5) Previous issue date: 2017-01-13 / Nenhuma / O acirramento da competitividade no ambiente industrial, relacionado ao fenômeno da globalização, direciona as organizações a buscar continuamente otimizar seus negócios. Um mercado formado por clientes cada vez mais exigentes sob o ponto de vista de preços, atendimento, qualidade e tecnologia, somado a uma competição com empresas internacionais tende a apresentar dificuldades para a competição das empresas brasileiras. Este cenário econômico aponta para o acirramento da competição através do aumento da variedade de produtos e da redução do tamanho dos lotes de fabricação. O referencial teórico busca apresentar os principais aspectos teóricos acerca do impacto que a variedade de produtos causa sobre os sistemas produtivos e também as principais metodologias e técnicas que auxiliam no entendimento e padronização do portfólio de componentes. A partir desde cenário, o presente trabalho propõe um método geral para implantação de um programa de padronização que tem por objetivo auxiliar na redução de variedade de componentes, mantendo a mesma diversidade de produtos ofertados ao mercado. O método de pesquisa foi o Design Research e a etapa empírica do trabalho foi realizada em uma empresa do setor metal-mecânico, localizada em Farroupilha (RS). O método proposto teve como base cinco fontes de informação: i) os conceitos e técnicas existentes no âmbito da literatura; ii) proposições teóricas da pesquisa; iii) conhecimento empírico de um grupo de especialistas, que avaliou o método antes de sua aplicação; iv) contribuição dos profissionais da empresa e do próprio pesquisador a partir da aplicação do método; e v) a avaliação do método a partir da aplicação do mesmo em ambiente empresarial. Ao término do estudo, chegou-se a uma proposta final de método que está disponível para novas aplicações. / The intensification of competitiveness in the industrial environment, related to the phenomenon of globalization, directs organizations to continuously seek to optimize their businesses. A market made up of increasingly demanding customers from the point of view of prices, service, quality and technology, coupled with a competition with international companies tends to present difficulties for the competition of Brazilian companies. This economic scenario points to the intensification of competition by increasing the variety of products and reducing the size of manufacturing lots. The theoretical framework seeks to present the main theoretical aspects about the impact that the variety of products has on the productive systems and also the main methodologies and techniques that help in the understanding and standardization of the component portfolio. From this scenario, the present work proposes a general method for the implementation of a standardization program whose objective is to help reduce the variety of components while maintaining the same diversity of products offered to the market. The research method was Design Research and the empirical stage of the work was carried out in a metal-mechanic company located in Farroupilha (RS). The proposed method was based on five sources of information: i) the concepts and techniques existing in the literature; ii) theoretical propositions of the research; iii) empirical knowledge of a group of experts, who evaluated the method before its application; iv) contribution of the professionals of the company and the researcher himself from the application of the method; and v) the evaluation of the method from the application of the same in business environment. At the end of the study, a final method proposal was made available for new applications.
50

Padronização de uma técnica para medida da espessura e do volume endometrial por ultrassonografia tridimensional: um estudo de confiabilidade e concordância intra e interobservador / Standardized measurement technique may improve the reliability of measurements of endometrial thickness and volume

Leite, Stael Porto 15 December 2011 (has links)
Introdução: A avaliação endometrial à ultrassonografia, em geral, tem sua aplicação clínica em larga escala dentro do ciclo reprodutivo feminino, porém, (até onde se sabe), sem uma forma padronizada para a realização dessas medidas. Objetivo: O objetivo deste estudo foi avaliar se a padronização do exame ultrassonográfico tridimensional (US-3D) do útero ao modo multiplanar -\"standardization of the multiplanar view\" - (SMV) melhora a confiabilidade intra e interobservador e a concordância em relação às medidas endometriais. Casuística e Métodos: Foram realizados exames utrassonográficos, ao modo bidimensional (US-2D) e tridimensional (US-3D) em 30 mulheres submetidas a tratamento em reprodução assistida. Dois observadores mediram a espessura endometrial utilizando US-2D e US-3D. O volume endometrial foi avaliado por meio do sistema computadorizado VOCAL(TM) em planos longitudinal (A) e coronal (C) utilizando o exame multiplanar de forma não padronizada - \"unmodified multiplanar view\" (UMV) e aquele sob a forma padronizada - \"standardized multiplanar view\" (SMV). O coeficiente de correlação intraclasse (CCI) foi empregado para avaliar a confiabilidade entre as medidas. A concordância foi avaliada colculando-se a média das diferenças e dos \"limites de concordância de Bland-Altman (LoA)\". O grau de facilidade em delimitar e contornar a interface endométrio-miométrio ao plano A ou C foi determinado de forma subjetiva. Resultados: A medida do volume endometrial utilizando o SMV ao plano A mostrou-se mais confiável (IC intra e interobservador 0,979 e 0,975) do que a medida da espessura endometrial utlizando US-2D (CCI = 0,742 e 0,702) ou US-3D (CCI = 0,890 e 0,784). Os limites de concordância interobservadores e confiabilidade intraobservador para medidas do volume endometrial foram maiores ao método padronizado (SMV) utilizando o plano A, do que aquele não padronizado (VUM), tanto ao plano A quanto ao plano C. Chama a atenção os intervalos de confiança serem ainda mais estreitos ao plano A. Não houve diferença significativa com relação à confiabilidade ou concordância entre as medidas realizadas, tanto ao plano A quanto ao plano C, utilizando-se o método padronizado (SMV). No entanto, os observadores concordaram que o delineamento da interface endométrio-miométrio a partir do plano A foi mais fácil (50,0% para o primeiro observador e 46,7% para o segundo observador), ou comparáveis aos planos A e C (50% para o primeiro observador e 53,3% para o segundo observador), mas nunca ao plano A mais difícil do que ao plano C. Conclusões: As medidas do volume endometrial são mais confiáveis do que as da espessura endometrial, sendo melhor realizadas quando utilizado o método padronizado (SMV) ao plano A. / Introduction: Endometrial assessment with ultrasonography usually has its clinical application on a large scale in female reprodutive cycle but (as far as we know) without a standard way to perform these measures. Objective: The objective of this study was to evaluate if standardization of the multiplanar view (SMV) when assessing the uterus using three-dimensional ultrasonography (3D-US) improves the intra- and interobserver reliability and agreement with regard to endometrial measurements. Casuistic and Methods: Ultrasound imaging exams were performed, using the bidimensional ultrasonography (2D US) and 3D-US, in 30 women undergoing assisted reproduction treatment. Endometrial thickness was measured by two observers using 2D-US and 3DUS. Endometrial volume was measured with VOCAL(TM) in the longitudinal (A) and Coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was evaluated by calculating mean difference and limits of agreement (LoA). The ease to contour the endometrial-myometrial interface was compared between the A and C plane using subjective assessment. Results: Endometrial volume measurements using the SMV and A plane were more reliable (Intra- and interobserver IC 0.979 and 0.975) than measurements of endometrial thickness using 2D-US (ICC=0.742 and 0.702) or 3D-US (ICC=0.890 and 0.784). The interobserver agreement and intraobserver reliability for endometrial volume measurements was better using SMV and A plane than UMV using A or C plane LoA being narrower for the former. No significant difference in reliability or agreement was demonstrated between the A and C plane when using SMV. However the observers agreed that delineating the endometrial-myometrial interface using the A plane was easier (50.0% and 46.7%, first and second observer) o \'comparable\' (50% and 53.3%), but never more difficult than using the C plane. Conclusion: Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and A plane.

Page generated in 1.2516 seconds