• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 318
  • 9
  • 9
  • 9
  • 9
  • 5
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 321
  • 321
  • 223
  • 222
  • 112
  • 97
  • 78
  • 44
  • 40
  • 38
  • 38
  • 25
  • 24
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Relação entre parâmetros do metabolismo redox e a agressividadede de câncer de pulmão de não pequenas células

Motta, Leonardo Lisbôa da January 2011 (has links)
O câncer de pulmão é a neoplasia maligna mais letal em todo o mundo. As terapias disponíveis são pouco eficazes e a alta mortalidade não têm se alterado ao longo dos anos. O câncer de pulmão de não pequenas células (NSCLC do inglês non small cell lung cancer) representa 80% dos casos e pode ser dividido em três subtipos histológicos: adenocarcinoma (AdC), carcinoma de células grandes (LCC do inglês large cell carcinoma) e carcinoma escamoso. Células tumorais possuem maior capacidade de proliferação, migração e invasão. São também incapazes de responder a sinais que inibam proliferação ou ativem morte celular programada e ainda estimulam a formação de novos vasos sanguíneos. Todos estes aspectos são afetados pelo metabolismo redox, cuja homeostase intracelular é mantida pelo equilíbrio entre oxidantes e antioxidantes. A homeostase redox das células pulmonares é afetado pela exposição à grande pressão de O2 e oxidantes ambientais, devido à fisiologia deste órgão. Além disso, todo tumor sólido se desenvolve num microambiente de inflamação crônica com alta produção de espécies reativas (ER). Portanto, a tumorigênese selecionará células adaptadas para sobrepujar este ambiente oxidativo em seu favor. Discute-se que a elevação de defesas antioxidantes contribua para esta adaptação. Porém, apesar de níveis elevados de ER poderem causar morte celular por estresse oxidativo, hoje se sabe que um aumento moderado nestes níveis modula processos fisiológicos relevantes à agressividade tumoral, como os citados a cima. Assim, o presente trabalho teve como objetivo investigar a relação entre o metabolismo redox intracelular e a agressividade tumoral em NSCLC. Foram utilizadas 4 linhagens humanas de NSCLC de dois tipos histológicos: AdC (A549 e EKVX) e LCC (H-460 e HOP-92). Foram avaliados dois parâmetros de agressividade tumoral (invasividade e quimioresistência), obtendo-se uma linhagem claramente mais agressiva em cada subtipo histológico. Após, foi analisado o perfil redox intracelular em função da agressividade. Concluiu-se que as linhagens mais agressivas possuem um desbalanço enzimático sugerindo uma elevação no steadystate da produção de ER, confirmada posteriormente pelo ensaio de DCF. Estas linhagens apresentaram ainda potencial antioxidante total e o nível de tióis reduzidos (-SH) diminuídos e índice de lipoperoxidação aumentado. Esses dados corroboram os resultados anteriores e juntos caracterizam o ambiente redox intracelular das linhagens mais agressivas como mais pró-oxidante. Caso houvesse aumento nas defesas antioxidantes durante a progressão tumoral, esperaríamos um estado redox mais redutor, porém, o presente trabalho demonstra o contrário. Posteriormente, foi avaliada a influência da espécie reativa peróxido de hidrogênio (H2O2) em dois parâmetros de malignidade tumoral. Na proliferação celular, o H2O2 se mostrou um mediador necessário, uma vez que sua remoção inibe este processo. Ainda, sua adição estimulou maior proliferação nas linhagens mais agressivas. O H2O2 também foi capaz de aumentar a taxa de migração celular, enquanto sua remoção a inibiu parcialmente. Desta forma, pode-se concluir que o desbalanço redox favorecendo ambiente intracelular pro-oxidante acompanha a progressão tumoral em NSCLC. Além disso, ela é fundamental à malignidade das células tumorais de NSCLC. Assim, o uso de antioxidantes como terapia adjuvante possivelmente é uma alternativa viável para melhorar o prognóstico de câncer de pulmão de não pequenas células. / Lung cancer is the most lethal malignant neoplasy worldwide. The available therapies have little efficacy and the high death rate has not been changed in the last decade. Non small cell lung cancer (NSCLC) accounts for 80% of the cases and can be sub-classified in three histological subtypes: adenocarcinoma (AdC), large cell carcinoma (LCC) and squamous cell carcinoma. Cancer cells have elevated capacity to proliferate, migrate and invade. Also, they stimulate the growth of new blood vessels and are insensitive to signals that inhibit proliferation or activate programmed cell death. All of there aspects are influenced by redox metabolism, which homeostasis is maintained by the equilibrium between oxidants and antioxidants. The redox homeostasis of pulmonary cells is affected by the exposure to elevated O2 pressure and environmental oxidants, due to the physiology of the lungs. Besides, every solid tumor develops in a chronic inflammatory microenvironment with elevated production of reactive species (RS). Thus, the occurrence of a tumor must select those cells necessarily capable of dealing with this oxidative environment. It is believed that this success could be achieved with an increased antioxidant capacity. Although elevated levels of RS can cause oxidative stress-mediated cell death, nowadays it is known that mild increase in RS levels can influence the physiology of the cell, including the aspects mentioned earlier. This way, the present study aimed to investigate the association between intracellular redox metabolism and tumor aggressiveness in NSCLC. Four human NSCLC cell lines were used divided in two histological subtypes: AdC (A549 and EKVX) and LCC (H-460 and HOP-92). In first place, it was evaluated two aggressiveness parameters (invasiveness and chemoresistance), obtaining one cell line clearly most aggressive within each histological subtype. Then, the intracellular redox profile was evaluated and analyzed in light of aggressiveness. We found that the most aggressive cell lines have an enzymatic imbalance suggesting an elevation of steady-state RS production, further confirmed by DCF assay. These cell lines also showed lower reduced thiol (-SH) levels and total antioxidant potential, and higher lipoperoxidation index. This data corroborates previous conclusion and collectively characterize the intracellular redox environment of the most aggressive cell lines as more pro-oxidant. If tumor progression were followed by elevation in antioxidant defenses, one would expect a reducer intracellular environment, however this work demonstrates the opposite. Hence, the influence of the RS hydrogen peroxide (H2O2) in malignant parameters was evaluated. In proliferation, H2O2 could be defined as a necessary mediator, once its removal inhibited this process. Moreover, addition of H2O2 stimulated higher proliferation in the most aggressive cell lines. Hydrogen peroxide was also capable of enhance the migratory rate, while its removal partially inhibited it. Concluding, the redox imbalance favoring pro-oxidative intracellular environment might follows NSCLC tumor progression. Furthermore, it is essential to tumor malignancy in NSCLC. This way, the use of antioxidants as adjuvant therapy could be a viable alternative to improve the prognostic of non small cell lung cancer.
172

Avaliação do efeito do dióxido de titânio ativado por luz visível no clareamento dental

Souza, Marcela Oliveira de January 2015 (has links)
Clareamento dentário é atualmente um dos tratamentos estéticos mais requisitados na odontologia devido ao crescimento da exigência estética por parte dos pacientes. Assim, pesquisas sobre o tema tem avançado buscando aprimorar materiais e protocolos. Este estudo tem como objetivo avaliar o efeito da ação fotocatalizadora do dióxido de titânio (TiO2) ativado por luz visível adicionado à baixa e alta concentração de peróxido de hidrogênio (H2O2) e sua eficácia no processo clareador dentário diante da redução do período de aplicação. A ação fotocatalizadora do TiO2 foi avaliada utilizando uma solução de H2O2 3,5 e 35% e azul de metileno (AM). A análise de cor (ΔE) foi realizada em dentes bovinos empregando H2O2 gel 6% e 35%. As amostras foram fotoativadas durante 5min utilizando um aparelho de LED. O tempo total de de ação foi de 15min; apenas para o grupo controle aplicado em dente o total foi de 45min (H2O2 35% sem TiO2). Os grupos contendo H2O2 3,5 ou 35%, AM e TiO2 seguido de fotoativação apresentaram diferença estatísticamente significativa quando comparado com os demais grupos testados. Entretanto, quando as duas concentrações foram comparadas também houve diferença significativa, apresentando com 35% maior diminuição da concentração de AM. Nos testes realizados em dentes bovinos, 35% H2O2 gel e TiO2 não apresentaram diferença para o grupo controle. Quando a concentração (6%) e tempo de aplicação foram conjuntamente reduzidos houve diferença em relação ao controle. Porém, todos os grupos avaliados apresentaram ΔE acima de 3,3. H2O2 em alta e baixa concentração com adição de TiO2 , luz e redução do tempo de ação foram considerados efetivos para aplicação em claremento dentário. / Tooth whitening is currently one of the most requested aesthetic treatments in dentistry. Thus, research studies have attempted to improve the materials and protocols used in this treatment. This study evaluated the photocatalyst effects of visible light activated titanium dioxide (TiO2) employed in low and high hydrogen peroxide (H2O2) concentrations with a reduced application period. TiO2 effect was evaluated using seven H2O2 solutions (3.5 and 35%) and methylene blue (MB). Color analysis (ΔE) was performed on bovine teeth using H2O2 gel 6 and 35% (GH2O235%, GH2O235%+TiO2 and GH2O26%+TiO2). The samples were light activated (LA) for 5 minutes using an LED device. Total action time was 15min. For the control group (GH2O235%), the action time was 45min. Solutions containing MB, H2O2 at 3.5 or 35%, and TiO2, followed by LA, showed a statistically significant difference when compared with the other groups tested. However, when the two concentrations were compared, significant difference was also found, showing greater MB reduction for 35%. In tests employed on bovine teeth, GH2O235%+TiO2 gel showed no difference in comparison to GH2O235% (the control group). When the concentration and application time were reduced (GH2O26%+TiO2), a statistical difference was found (p<0.05). Nevertheless, all groups showed ΔE higher than 3.3. Titanium dioxide and hydrogen peroxide association was affected by light activation. Thus, high and low H2O2 concentrations showed color difference in comparison to the baseline color and did so after a shorter application period when combined with TiO2, suggesting the effectiveness of this material and being promising of use to tooth bleaching.
173

Depilação enzimática-oxidativa de peles para curtimento

Marafon, Eliane Andrioli Matos January 2012 (has links)
A busca por tecnologias que visem minimizar o impacto ambiental da indústria coureira vem aumentando constantemente. A utilização de enzimas e de produtos oxidantes na etapa de depilação da pele é uma alternativa que permitem a redução do potencial poluidor da indústria do couro, além de possibilitar a redução do tempo de processo. Neste trabalho buscou-se reunir os benefícios do uso de enzimas, produzidas pelo cultivo de duas linhagens de Bacillus subtilis (BLBc 11 e BLBc 17), e peróxido de hidrogênio, através da associação destes produtos em um processo de depilação enzimático-oxidativo, alternativo ao processo convencional (cal e sulfeto de sódio). Foram realizados testes iniciais a fim de avaliar as melhores condições de depilação, verificando-se que as melhores condições seriam: realizar a primeira etapa somente com o extrato enzimático, alcalinizar o meio com 1% de hidróxido de sódio e realizar, então, a etapa oxidativa com peróxido de hidrogênio, com o tempo total de processo em torno de 4 h. Os testes de depilação enzimática-oxidativa foram realizados nestas condições, aplicando as enzimas nas concentrações de 100 U g-1 de pele e 300 U g-1 de pele, e o peróxido de hidrogênio nas concentrações de 4 % e 8 %. As peles foram visualmente avaliadas, observando-se que em todos os ensaios os pelos não foram totalmente removidos, conseguindo-se sua remoção com posterior raspagem mecânica. Os pelos foram removidos intactos, com a raiz. Foram realizados testes comparativos entre o método de depilação proposto, a depilação convencional e a depilação puramente enzimática. O banhos residuais foram avaliados através de análises de pH, nitrogênio total Kjeldhal, sólidos dissolvidos totais, fixos e voláteis, glicosaminoglicanos, proteoglicanos e hidroxiprolina. Os resultados foram satisfatórios, mostrando que o método de depilação com o uso de enzimas e peróxido de hidrogênio pode ser considerado uma alternativa viável ao uso de cal e sulfeto de sódio. / The search for technologies aiming at minimizing the environmental impact of leather industry is constantly increasing. The use of enzymes and oxidants in the unhairing step is an alternative which allow reducing the pollution of the leather industry, in addition to enabling the reduction of process time. In this study we sought to bring together the benefits of using enzymes, produced by two strains of Bacillus subtilis (BLBc 11 e BLBc 17), and hydrogen peroxide through the combination of these products in an enzymatic-oxidative unhairing, alternative to the conventional process (lime and sodium sulfide). Initially, tests were carried out to assess the best conditions for hair removal, verifying that the best conditions are: perform the first step only with the enzymatic extract liquid, alkalinization with 1% sodium hydroxide and, then, the oxidation step with hydrogen peroxide, with the total process time around 4 h. Tests for enzyme-oxidative unhairing were performed under these conditions, applying enzymes at concentrations of 100 U g-1 of skin and 300 U g-1 of skin, and hydrogen peroxide at concentrations of 4% and 8%. The skins were visually evaluated, observing that in all the tests the hairs were not completely removed, achieving its removal with subsequent mechanical scraping. The hairs were removed intact, with the roots. Tests were conducted comparing the proposed unhairing method, the conventional unhairing and purely enzymatic unhairing performed with enzymatic extract produced by strains BLBc 11 and BLBc 17. The residual baths were evaluated through analysis of pH, total Kjeldhal nitrogen, total dissolved solids, fixed and volatile, glycosaminoglycans, proteoglycans and hydroxyproline. The results were satisfactory, showing that the enzymatic-oxidative unhairing using enzymes and hydrogen peroxide proposed here can be considered a viable alternative to the use of lime and sodium sulfide.
174

Avaliação clínica da efetividade do clareamento em consultório de dentes polpados, com e sem o condicionamento ácido prévio do esmalte / Clinical evaluation of the effectiveness of in-office whitening tooth pulp, with and without prior acid etching of enamel

Cristiane Machado de Almeida 06 June 2011 (has links)
O objetivo deste estudo in vivo foi comparar a efetividade da técnica de clareamento em consultório, com fonte de luz híbrida (LED e Laser terapêutico), com e sem condicionamento ácido prévio do esmalte, em função do grau de mudança e estabilidade de cor e sensibilidade. Após serem informados dos objetivos do estudo, trinta e quatro voluntários foram selecionados de acordo com os critérios de inclusão e exclusão. Inicialmente, os voluntários receberam uma profilaxia supra gengival completa, em seguida, foi feita avaliação da cor com o espectrofotômetro Vita EasyShade (Vita). Os pacientes foram divididos aleatoriamente em dois grupos de 17, de acordo com o uso ou não de fonte de luz, e sempre no hemi-arco superior e inferior direito foi realizado o condicionamento do esmalte com ácido fosfórico a 37% durante 15s, previamente a aplicação do gel clareador. Nos grupos ativados os dois arcos dentários receberam tratamento com o gel clareador a base de PH a 35% (Lase Peroxide DMC Equipamentos) e após 1 min., a luz híbrida à base de LED/Laser (Whitening Lase II DMC Equipamentos) foi aplicada durante 3 min. simultaneamente em todos os dentes anteriores. Novamente foi feita uma espera de 1 min., com objetivo de resfriar o gel e então, nova ativação com a luz por mais 3 min. Nos grupos não ativados, o gel foi aplicado por 3 x de 15 min. Os pacientes retornaram após 24 h., 1 semana, 1 mês, 6 e 12 meses para novas avaliações da cor. A sensibilidade dentária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, após 24 h. e uma semana. Os resultados foram tabulados e receberam tratamento estatístico pela análise de variância a quatro e três critérios (ANOVA), teste de Tukey (0,05%), Mann-Whitney e Wilcoxon. Nenhuma diferença significante de alteração de cor, estabilidade do clareamento (12 meses) e sensibilidade foi encontrada entre os grupos. No grupo I, o uso da luz e do condicionamento ácido gerou a necessidade de um tempo menor (31,5), de aplicação do gel, que no hemiarco não condicionado (grupo II) que foi de (34,3), esses tempos foram estatisticamente significante, quando comparado ao hemi-arco não condicionado (grupo II) e aos grupos III e IV (45), demonstrando a vantagem de associação desses dois recursos no clareamento em consultório. / The aim of this study was to compare the in vivo effectiveness of in-office bleaching technique with hybrid light source (LED and laser therapy), with and without prior acid etching of enamel, depending on the degree of change and stability of color and sensitivity . Upon being informed of the aims of the study was thirty-four volunteers were selected according to the criteria for inclusion and exclusion. Initially, the volunteers received a complete prophylaxis gum above, then evaluation was made of the color with the spectrophotometer Easyshade Vita (Vita). Patients were randomly divided into two groups of 17, according to the use or absence of light source, and always in the hemi-arch top and bottom right was performed enamel etching with phosphoric acid at 37% for 15s, prior to application of whitening gel. In both groups activated dental arches were treated with the whitening gel base to 35% PH (Lase Peroxide - DMC equipment) and after 1 min., Light-based hybrid LED / Laser (II Whitening Lase - DMC Equipment) was applied for 3 min. simultaneously in all the anterior teeth. Again it was made a 1 min., In order to cool the gel and then activated with the new light for 3 min. In groups not activated, the gel was applied for 3 x 15 min. Patients returned after 24 hours, 1 week and 1 month for new evaluations. The results were submitted to 4-way and 3-way ANOVA, Tukey test at significance level of 5%, Wilcoxon and Mann-Whitney Test. In group I, the use of light and acid etching generated the need for a shorter time (31.\'5\"), application of the gel, which in hemiarch not conditioned (group II) that was (34\'.3\"), these times were statistically significant when compared to hemi-arch non-conditioned (group II) and groups III and IV (45\'), demonstrating the advantage of the combination of these two resources in office whitening.
175

Influência do tempo de aplicação do bicarbonato de sódio a 10% na adesão ao esmalte bovino clareado: estudo in vitro / Effect of the application time of 10% sodium bicarbonate on bleached enamel: an in vitro study

Marina Studart Alencar Borges 08 December 2016 (has links)
Este estudo in vitro avaliou a influência do tempo de aplicação do bicarbonato de sódio a 10% na qualidade da união de um sistema adesivo universal unido ao esmalte bovino clareado por meio de testes de resistência de união (microtração imediata e após 6 meses) e grau de conversão na interface adesiva (espectroscopia micro-Raman). Cento e dez blocos de esmalte bovino (4x4 mm) foram planificados e distribuídos aleatoriamente em 5 grupos: C: controle, sem clareamento; B: clareamento com peróxido de hidrogênio 35% (HP); BS3: clareamento com HP seguido de tratamento com a solução de bicarbonato de sódio 10% (BS) por 3 min; BS5: clareamento com HP seguido de tratamento com BS por 5 min; BS10: clareamento com HP seguido de tratamento com BS por 10 min. O HP foi aplicado duas vezes (20 minutos cada, com exceção do grupo C) e em seguida as restaurações adesivas foram realizadas. Após 24 horas, 20 espécimes de cada grupo foram seccionados em palitos (1x1 mm) e submetidos ao teste de resistência de união (imediato e após 6 meses) em máquina de ensaios universal com velocidade de 0,5 mm/min (n=10). Os dados foram analisados por ANOVA a dois critérios (p <0,05). As médias das análises imediata e após 6 meses foram: C: 26,77 / 25,32; B: 26,42 / 26,42; BS3: 23,95 / 22,98; BS5: 23,65 / 26,64; BS10: 23,42 / 29,30. Nenhum dos fatores testados apresentou significância: tratamento (p=0,349) e tempo (p=0,234), não havendo interação entre estes (p=0,198). Falhas adesivas foram predominantes nos dois períodos de avaliação. Para a análise do grau de conversão, após 24 horas da restauração, 2 espécimes de cada grupo foram seccionados em fatias de 1mm, sendo apenas 3 fatias selecionadas. Os seguintes parâmetros foram utilizados: excitação dos espécimes com laser de argônio operando a 538 nm, espectro obtido a uma resolução ~4cm-1, sob uma região de espectro entre 1580-1660cm-1, verificando a altura dos picos 1608cm-1 e 1637cm-1. Os dados foram analisados por ANOVA a um critério (p <0,05) e as médias do grau de conversão foram: C: 71,10%; B: 72,11%; BS3: 73,98%; BS5: 69,25%; BS10: 70,56%. O fator de estudo tratamento não apresentou significância estatística (p=0,808). A adesão no esmalte clareado parece não ter sido afetada negativamente quando restaurações adesivas foram feitas imediatamente após o clareamento, independente da aplicação ou não da substância antioxidante. Mais estudos que avaliem a adesão em esmalte clareado, principalmente no que diz respeito ao grau de conversão e aos diferentes tipos de sistemas adesivos universais se fazem necessários para fins comparativos e para que possamos indicar seguramente as restaurações imediatas (quando necessárias) na prática clínica. / The present in vitro study evaluated the influence of the application time of 10% sodium bicarbonate in the adhesion quality of a universal adhesive system bonded to bleached enamel through microtensile bond strength testing (immediate and after 6 months) and the degree conversion (micro-Raman spectroscopy). One hundred and ten bovine enamel blocks (4x4mm) were flattened and randomly allocated into 5 groups: C: control, without bleaching; B: bleached with 35% hydrogen peroxide (HP); BS3: bleached and treated with 10% sodium bicarbonate solution (BS) for 3 min; BS5: bleached and treated with BS for 5 min; BS10: bleached and treated with BS for 10 min. HP was applied twice (20 minutes each, except in group C) and the adhesive restorations were performed. After 24 hours, 20 specimens from each group were sectioned into sticks (1x1 mm) and submitted to microtensile bond strength testing (immediately and after 6 months) in a universal testing machine with a crosshead speed of 0.5 mm/min (n = 10). Data was analyzed by two-way ANOVA (p <0.05). The means of the immediate and 6 months analysis were: C 26.77 / 25.32; B: 26.42 / 26.42; BS3: 23.95 / 22.98; BS5: 23.65 / 26.64; BS10: 23.42 / 29.30. None of the tested factors showed significance: treatment (p = 0.349) and time (p = 0.234), with no interaction between them (p = 0.198). Adhesive failures were predominant in both evaluation periods. For the degree of conversion analysis, 2 specimens of each group were sectioned into 1 mm slices after 24 hours of the restorative procedure, and 3 slices were selected. The following parameters were used: excitation of specimens with argon laser operating at 538 nm, spectrum obtained at a resolution of ~4cm-1, under a spectrum region between 1580-1660cm-1, evaluating the height of the peaks at 1608cm-1 and 1637cm-1. Data was analyzed by one-way ANOVA (p <0.05). The means of degree of conversion were: C: 71.10%; B: 72.11%; BS3: 73.98%; BS5: 69.25%; BS10: 70.56%. The study factor \"treatment\" was not statistically significant (p = 0.808). The results of bonding to bleached enamel was not negatively affected when adhesive restorations were made immediately after bleaching, regardless of the application of the antioxidant substance. Further studies to evaluate the adhesion on bleached enamel, mainly with regard to the degree of conversion and different types of universal adhesive systems are needed for comparative purposes. Only after this, the immediate restoration (if necessary) in clinical practice can be safely and indicated.
176

Fotodegradação de polímeros solúveis em água e moléculas modelo via processos oxidativos avançados / Photodegradation of water soluble polymers and model molecules via advanced oxidative processes

Laís Calixto Santos 13 October 2008 (has links)
Neste trabalho foi investigado o mecanismo de fotodegradação de polímeros e também a ação de agentes estabilizantes. Foi investigada a degradação oxidativa de polímeros solúveis em água como poli(vinilpirrolidona), PVP; poli(acrilamida), PAM e poli(etilenoglicol), PEG na presença de peróxido de hidrogênio, reagente de Fenton e sal de ferro. O PVP apresentou a menor fotoestabilidade enquanto a PAM apresentou a maior fotoestabilidade. O sal de ferro não promoveu a degradação. As soluções de PEG foram fotooxidadas com os sistemas UV/H2O2, Fenton e foto-Fenton e as amostras foram analisadas por GPC e HPLC. A análise por GPC das soluções de PEG mostrou que em todas as condições oxidativas usadas, a fotooxidação leva a uma queda acentuada da Mw, caracterizando um mecanismo de quebra de cadeia aleatório. Para os três sistemas usados, a polidispersidade aumenta após a degradação, confirmando o mecanismo de quebra aleatória de cadeia. As medidas de GPC também mostraram que a velocidade de degradação é muito maior com o sistema foto-Fenton (kd = 1,010-4 mol.g-1.min-1), seguida pelo sistema UV/H2O2 (kd = 3,610-5 mol.g-1.min-1). O uso do reagente de Fenton apresentou a menor velocidade de degradação (kd = 1,110-6 mol.g-1.min-1). Os produtos de degradação do PEG, nos três sistemas analisados, foram analisados por HPLC, sendo identificados produtos de menor peso molecular, entre eles, EG, 2EG, 3EG, 4EG, e os ácidos glicólico e fórmico. O mecanismo envolve um processo consecutivo em que os etilenoglicóis de maior peso molecular dão origem aos de menor peso molecular. Etilenoglicóis de cadeia curta foram usados com sucesso como moléculas modelo para prever o mecanismo de fotodegradação do PEG. Fenóis primários combinados com antioxidantes secundários contendo fósforo são os sistemas estabilizantes mais efetivos, amplamente usados na estabilização do processamento e na aplicação de olefinas a longo prazo. O mecanismo de reação de hidrólise dos antioxidantes fosfito, escolhidos para diferenciar na estrutura química e no conteúdo de fósforo, é investigado através da espectrometria de massas. Substituintes diferentes em torno do átomo de fósforo mostram um efeito significativo na estabilidade dos fosfitos com substituintes fenol, produzindo estruturas hidroliticamente estáveis. / The aim of this work was to investigate polymer photodegradation mechanisms and stabilizing agents. The course of photooxidative degradation of some water soluble polymers (poly(vinylpyrrolidone), PVP; poly(acrylamide), PAM and poly(ethylene glycol), PEG) in the presence of hydrogen peroxide, Fenton reagent and iron salt has been investigated. PVP showed the lowest photostability while PAM had the greatest photostability. Iron salt was not efficient promoting degradation. PEG has been photooxidized in Fenton, photo-Fenton and UV/H2O2 systems. Samples were analysed using GPC and HPLC. GPC analysis of PEG solutions showed that in all oxidizing conditions used, the photooxidation of PEG aqueous solutions leads to an abrupt decrease of Mw, which means that the degradation of PEG implies a random chain scission mechanism. Polydispersity increases after degradation in all the systems used, confirming a random chain scission mechanism. GPC analysis also showed that the rate of degradation is much higher for the photo-Fenton system (kd = 1,010-4 mol.g-1.min-1), followed by UV/H2O2 system (kd = 3,610-5 mol.g-1.min-1 ). Fenton reagent has the lowest degradation rate (kd = 1,110-6 mol.g-1.min-1). The degradation products of PEG in all oxidizing systems, were analyzed by HPLC and lower molecular weight products were detected, i.e., EG, 2EG, 3EG, 4EG, glycolic and formic acids. The mechanism involved a consecutive process, were the larger ethyleneglycols gave rise, successively, to smaller ones. This suggested that the mechanism involved successive scissions of the polymer chain. Ethyleneglycols were successfully used as model molecules to predict PEGs photodegradation mechanism. Primary hindered phenols in combination with phosphorous-based secondary antioxidants are one of the most effective stabilizing systems, widely used in the processing stabilization and long-term application of polyolefins. The hydrolysis reaction mechanism of phosphite antioxidants, chosen to differ in chemical structure and phosphorus content, is investigated by mass spectrometric means. The analytes under investigation are exposed to accelerated humid ageing conditions and their hydrolytic pathway and stability is investigated. Different substituents around the phosphorus atom are shown to have a significant effect on the stability of the phosphites with phenol substituent producing very hydrolytically stable structures.
177

A metanandamida, um agonista canabinóide, protege a linhagem de neuroblastoma neuro2A da morte celular induzida por peróxido de hidrogênio. / The methanandamide, a cannabinoid agonist, protect the lineage of neuro 2A cell death induced by hydrogen peroxide.

Luciana Gonzalez Auad 02 July 2012 (has links)
As doenças neurodegenerativas são desordens progressivas que afetam determinadas populações neuronais do sistema nervoso central, levando a morte neuronal. Vários fatores contribuem para o desenvolvimento das doenças neurodegenerativas, dentre eles o aumento da formação de radicais livres e/ou estresse oxidativo. O sistema canabinóide vem sendo sugerido como um importante sistema neuroprotetor em diversos modelos de neurodegeneração. Os objetivos do presente estudo foram avaliar a participação do sistema canabinóide em um modelo de morte celular in vitro induzida pelo peróxido de hidrogênio. O modelo celular utilizado foi a linhagem Neuro 2A. Realizamos os tratamentos conjugados para verificar a possível função neuroprotetora do sistema canabinóide. Obtivemos resultados de neuroproteção da Metanandamida revertendo o quadro de morte celular induzido pelo peróxido de hidrogênio. Acreditamos que esta neuroproteção seja via CB1 que inibe os canais de cálcio dependentes de voltagem talvez contribuindo para a redução da progressão da excitotoxicidade. / Neurodegenerative diseases are progressive disorder affecting specific neuronal populations in the central nervous system, leading to neuronal death. Several factors contribute to the development of neurodegenerative diseases, including increased free radical formation and / or oxidative stress. The cannabinoid system has been suggested as an important system neuroprotective in several models of neurodegeneration. The objectives of this study were to evaluate the involvement of the cannabinoid system in a model of in vitro cell death induced by hydrogen peroxide. The model used was the cell line Neuro 2A. Performed the treatments combined to verify the possible neuroprotective effects of the cannabinoid system. We obtained results of neuroprotection Methanandamide reversing the framework of cell death induced by hydrogen peroxide. We believe that this is via neuroprotection CB1 that inhibits calcium channels of voltage-dependent perhaps contributing to the reduction of the progression of excitotoxicity.
178

Análise da permeação de H2O2 amelodentinária através de métodos eletroquímicos / Analysis of enameldentin permeation of H2O2 by electrochemical methods

Alexander Cassandri Nishida 24 April 2013 (has links)
Existem muitas metodologias utilizadas para tentar analisar a permeação de peróxido de hidrogênio através das estruturas dentárias, porém não conseguem determinar o momento exato em que o peróxido começa a alcançar concentrações detectáveis dentro da câmara pulpar. OBJETIVO: Investigar a viabilidade de um modelo experimental de análise eletroquímica para detecção e mensuração da concentração de peróxido de hidrogênio proveniente de produtos utilizados em tratamento clareador e avaliar a cinética da difusão destes peróxidos através dos tecidos duros dentários. MATERIAIS E MÉTODOS: Foram utilizados 45 dentes incisivos bovinos permanentes mandibulares, cujo preparo envolveu a remoção da face lingual coronária, mantendo-se o esmalte e a dentina vestibulares intactos. Todos os dentes foram fixados em resina acrílica com auxílio de matriz elastomérica quadrangular e organizados segundo os testes: 1: análise eletroquímica e 2: análise espectrofotométrica. Para os testes foram utilizados clareadores à base de peróxido de hidrogênio (HP) e de peróxido de carbamida (CP) e seus respectivos placebos (PHP e PCP). Foram realizados três cronoamperogramas e três voltamogramas para cada uma das amostras. Utilizou-se a mesma cela no experimento eletroquímico e no teste espectrofotométrico, permitindo assim a comparação das metodologias. RESULTADOS: A análise eletroquímica mostrou na 1ª permeação de HP média de 1688,50 segundos quando comparada a 857,70s e a 457,70s da 2ª e da 3ª permeações, respectivamente. Desta forma observa-se que a 1ª permeação representa aproximadamente o dobro e o quadruplo dos valores sequenciais da 2ª e da 3ª permeações. Não foi detectado início de permeação para CP, PHP e PCP. Para o grupo HP há uma relação crescente nas concentrações de moléculas de peróxido de hidrogênio detectadas nas três permeações respectivamente. Entretanto, o crescimento entre a 1ª e 2ª permeação é discreto, quando comparado à 3ª permeação, onde foi detectada maior concentração de moléculas do peróxido de hidrogênio. No grupo CP observam-se médias de 2,96E-02 A na 1ª permeação, 3,11E-05 A na 2ª permeação e 1,37E-04 A na 3ª permeação, havendo diferença entre a 1ª e 3ª permeação (p = 0,00472). Todavia, não ocorreram diferenças entre os demais grupos (p > 0,05). Quando comparado o método eletroquímico e o método espectrofotométrico, o peróxido de hidrogênio (HP) não demonstrou diferença significativa entre as análises (p =0,0826); todavia o peróxido de carbamida mostrou diferenças entre as duas análises (p=0,0093). CONCLUSÕES: A metodologia eletroquímica é tão eficaz quanto à metodologia consolidada na literatura para a detecção da presença de peróxido de hidrogênio na câmara pulpar, nos testes com peróxido de hidrogênio 35%. O tempo necessário para que o peróxido de hidrogênio chegasse à câmara pulpar diminuiu a cada aplicação e a penetração do peróxido de hidrogênio aumentou a permeabilidade dos tecidos duros dentais. / There are many methods used to analyze the permeation of hydrogen peroxide through the tooth structure, but they cannot determine the exact moment when the peroxide begins to reach detectable concentrations within the pulp chamber. OBJECTIVE: To investigate the feasibility of an experimental model of electrochemical analysis for detection and measurement of the concentration of hydrogen peroxide from products used in bleaching and evaluate the kinetics of diffusion of these peroxides through dental hard tissues. MATERIALS AND METHODS: We used 45 bovine permanent mandibular incisors, whose preparation involved removing the lingual coronary hard tissues keeping intact the vestibular enamel and dentin. All teeth were fixed in acrylic resin with the aid of elastomeric matrix square and organized according to the tests: 1: electrochemical analysis and 2: spectrophotometric analysis. For tests were used based bleaching hydrogen peroxide (HP) and carbamide peroxide (CP) and their respective placebos (PHP and PCP). Three cronoamperograms and three voltammograms were performed for each sample. We used the same cell to the spectrophotometric test, thus allowing comparison of methodologies. RESULTS: The analysis showed the 1st electrochemical permeation HP average of 1688.50 seconds when compared to 857.70s and 457.70s of the 2nd and 3rd permeations respectively. Thus we observe that the 1st permeation is approximately double and quadruple sequential values of the 2nd and the 3rd permeations. Not detected early permeation for CP, PHP and PCP. For Group HP there is a ratio of molecules increasing concentrations of hydrogen peroxide detected in three permeations respectively. However, the growth between the 1st and 2nd permeation is understated when compared to 3rd permeation, where there has been a greater concentration of molecules of hydrogen peroxide. In the CP group were observed averages of 2.96 E-02A in the 1st permeation, 3.11 E-05 A in the 2nd permeation and 1.37 E-04 A in 3rd permeation, no difference between 1st and 3rd permeation (p = 0.00472) . However, there were no differences between the other groups (p> 0.05). When compared the electrochemical and spectrophotometric methods, hydrogen peroxide (HP) showed no significant difference between the analysis (p = 0.0826), yet the carbamide peroxide showed differences between the two analyzes (p = 0.0093). CONCLUSIONS: The electrochemical method is as effective as the consolidated methodology in the literature to detect the presence of hydrogen peroxide in the pulp chamber, in the tests with hydrogen peroxide 35%. The time required for the hydrogen peroxide to reach the pulp chamber decreased to each application and the penetration of hydrogen peroxide increased the permeability of dental hard tissues.
179

Efeito da estrutura de espinélios mistos de cobalto e manganês na decomposição catalítica do peróxido de hidrogênio para aplicação em propulsores de satélites / Effect of cobalt and manganese mixed spinel structure on the catalytic decomposition of hydrogen peroxide for application in satellite propellers

Luís Gustavo Ferroni Pereira 02 February 2018 (has links)
Este trabalho teve como objetivo o desenvolvimento de materiais catalíticos à base de espinélios de cobalto e manganês, para serem empregados como catalisadores na decomposição do peróxido de hidrogênio (H2O2) 90%, em massa, proporcionando múltiplas partidas a frio em um micropropulsor de satélites a monopropelente. Os materiais foram avaliados, preliminarmente, na decomposição espontânea do H2O2 (teste da gota). Este teste permitiu selecionar os materiais que proporcionaram uma decomposição do H2O2 90% mais rápida e vigorosa, com um baixo tempo de indução. Os materiais catalíticos selecionados no teste da gota foram avaliados em um micro reator de leito fixo, que permitiu determinar a composição e a granulometria ideais para o catalisador. Em seguida, os materiais foram submetidos a testes cinéticos, onde foram determinadas a ordem, a constante e a energia de ativação da reação de decomposição do H2O2. Por fim, o catalisador denominado Co0,5Mn2,5-900, por apresentar os melhores resultados nos ensaios cinéticos e no micro reator, foi testado em um micropropulsor de 2 N, onde apresentou um desempenho rápido e repetitivo, sendo capaz de decompor espontaneamente o H2O2 sem sofrer desativação ou fragmentação após os testes. Os catalisadores foram caracterizados pelas técnicas de Espectrometria de Emissão Ótica por Fonte de Plasma (ICP-OES), Adsorção de Nitrogênio, Quimissorção de CO, Picnometria a Hélio, Difratometria de Raios X, Espectroscopia Fotoeletrônica de Raios X e por análises de Resistência Mecânica a Compressão, visando estabelecer uma correlação entre as propriedades físico-químicas e a atividade catalítica de cada material na decomposição H2O2 concentrado. / This work aimed to develop catalytic materials based on cobalt and manganese spinels to be used as catalysts in the decomposition of 90% (mass) hydrogen peroxide, allowing multiple starts in a microthruster of monopropellant satellites. The catalysts were preliminarily evaluated in the spontaneous decomposition of H2O2 (drop test). This test allowed to select the materials that provide spontaneous and vigorous decomposition of H2O2, with a low induction time. Then, the best performing catalysts were evaluated in a fixed bed micro reactor, which allowed to determine the best composition and granulometry for the catalyst. After this, the materials were submitted to kinetic tests, where the order, the constant and the activation energy of the H2O2 decomposition reaction were determined. Finally, the catalyst called Co0,5Mn2,5-900, due its best performance, was tested in a 2 N microthruster, where it presented a fast and repetitive performance, being able to spontaneously decompose the H2O2 without suffer deactivation or fragmentation after the testes. All catalysts were characterized by Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES), Nitrogen Adsorption, CO Chemimetry, Helium Picnometry, X-ray Diffractometry, X-ray Photoelectron Spectroscopy and Mechanical Compression Resistance analysis aiming to correlate their physicochemical properties with their activity in the catalytic decomposition of concentrated hydrogen peroxide.
180

Síntese e caracterização de óxidos mistos de cobalto, manganês e alumínio para decomposição catalítica de H2O2 70% e geração de vapor / Synthesis and characterization of mixed oxides of cobalt, manganese and aluminum for catalytic decomposition of H2O2 70% and steam generation

André Navarro de Miranda 01 August 2016 (has links)
Este trabalho teve como objetivo o desenvolvimento de catalisadores mássicos à base de óxidos mistos de cobalto, manganês e alumínio, para a decomposição de peróxido de hidrogênio comercial, 70% em massa, e consequente geração de vapor d\'água. A síntese dos materiais foi realizada por coprecipitação em meio básico. Durante a reação foram sistematicamente estudados o pH do meio, a concentração inicial de carbonato, a velocidade de agitação, o tempo de envelhecimento, a influência da lavagem do precitado, o diâmetro médio das partículas e a temperatura e tempo de tratamento térmico. Os materiais foram caracterizados quanto as fases presentes, porcentagem mássica, massa específica, área específica, resistência mecânica e atividade catalítica, visando correlacionar suas propriedades físico-químicas com sua atividade na decomposição catalítica do peróxido de hidrogênio. Finalmente, os materiais que apresentaram melhor resistência mecânica e atividade catalítica foram testados em um sistema gerador de vapor. O melhor catalisador apresentou alta resistência mecânica, baixo tempo de indução e se mostrou ativo em testes de longa duração, possibilitando ao sistema alcançar temperaturas próximas à de decomposição adiabática do H2O2 70% em massa. / This work aimed to develop catalysts based on mixed oxides of cobalt, manganese and aluminum for the decomposition of commercial hydrogen peroxide, 70% p, inducing steam generation. The materials were synthesized by coprecipitation under alkaline condition. During reaction, were systematically studied the pH of the solution, the initial concentration of carbonate, the stirring speed, the aging time, the precipitate washing, the average particle diameter, the temperature and time of thermal treatment. The materials were characterized to determine the present phases, mass concentration, density, surface area, mechanical strength and catalytic activity, aiming to correlate their physicochemical properties with its activity on hydrogen peroxide catalytic decomposition. Once the best parameters were set, the best catalysts were tested in a steam generating system. The best catalyst have presented high mechanical strength, low induction time and proved to be active in long-term tests, enabling the system to reach temperatures close to the adiabatic decomposition of the H2O2 70% wt.

Page generated in 0.068 seconds