• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 121
  • 27
  • 27
  • 27
  • 27
  • 25
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 121
  • 121
  • 65
  • 47
  • 40
  • 28
  • 26
  • 24
  • 21
  • 20
  • 18
  • 17
  • 16
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Efeito da aplicação e fotoativação prévia de sistemas adesivos em cerâmica de dissilicato de lítio: análise da resistência de união e das propriedades mecânicas dos componentes resinosos da interface adesiva / Effect of the application and photocuring of adhesive systems on lithium dissilicate ceramics: analysis of the bonding strength and mechanical properties of resin components of the adhesive interface

Proni, Ana Teresa Maluly [UNESP] 10 August 2017 (has links)
Submitted by ANA TERESA MALULY PRONI null (atmaluly@gmail.com) on 2017-08-23T23:42:10Z No. of bitstreams: 1 Dissertação final PG.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-25T14:07:17Z (GMT) No. of bitstreams: 1 proni_atm_me_araca.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) / Made available in DSpace on 2017-08-25T14:07:18Z (GMT). No. of bitstreams: 1 proni_atm_me_araca.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) Previous issue date: 2017-08-10 / O objetivo deste estudo foi analisar o efeito da aplicação e da fotoativação prévia de diferentes sistemas adesivos em superfície de cerâmica de dissilicato de lítio, com ênfase na resistência da união cimento-cerâmica e na análise das propriedades mecânicas nanodureza e módulo de elasticidade dos diferentes adesivos e do cimento resinoso utilizado. Quarenta e nove blocos de resina composta (Z350XT A6B) e de blocos cerâmicos (e.max CAD LT D3) foram divididos em sete grupos experimentais (n=7), os quais foram cimentados entre si de acordo com o sistema adesivo utilizado na superfície dos blocos cerâmicos: Grupo 1: sem adesivo; Grupo 2: Adper™ Scotchbond™ Multi-Purpose Adhesive (SBMP) sem fotoativação; Grupo 3: SBMP com fotoativação; Grupo 4: Adper™ Single Bond 2 (SB2) sem fotoativação; Grupo 5: SB2 com fotoativação; Grupo 6: Single Bond Universal (SBU) sem fotoativação; Grupo 7: SBU com fotoativação. Em todos os grupos experimentais, o cimento resinono utilizado foi o RelyX Ultimate. Após 24 horas do processo de cimentação, todos os conjuntos foram submetidos à termociclagem entre 5°C e 55°C, com tempo de permanência de 28 segundos e tempo de transferência de 2 segundos para envelhecimento (10.000 ciclos). Os conjuntos foram então seccionados para obtenção de palitos para análise da resistência de união e das propriedades mecânicas de nanodureza e módulo de elasticidade dos adesivos e do cimento resinoso utilizado. Os dados foram submetidos à ANOVA e teste de Fisher (α = 0,05). Os resultados mostraram que os grupos SBMP e SB2 sem fotoativação apresentaram os menores valores de resistência de união, enquanto que para as propriedades mecânicas de nanodureza e módulo de elasticidade os maiores valores foram encontrados somente para o grupo SBMP com fotoativação, mostrando que a resistência de união foi influenciada pela interação dos materiais utilizados. Para as propriedades mecânicas analisadas, a fotoativação prévia dos sistemas adesivos não apresentou diferença estatisticamente significante na comparação entre os grupos. De acordo com os resultados obtidos, concluiu-se que a aplicação de sistemas adesivos na superfície silanizada da cerâmica se mostrou desnecessária. Dentre os adesivos estudados, o SBU foi o único material que se mostrou eficaz com ou sem fotoativação prévia. Para os demais adesivos estudados, SBMP e SB2, a fotoativação prévia se mostrou necessária para otimizar a resistência de união da interface adesiva estudada. / The aim of this study was to analyze the effect of the application and previous photoactivation of different adhesive systems on lithium dissilicate ceramics, with emphasis on the bond strength of cement-ceramic interface and the analysis of the mechanical properties (nanohardness and elastic modulus) of different adhesives systems and resin cement used. Forty-nine composite resin blocks (Z350XT A6B) and ceramic tablets (e.max CAD LT D3) which were divided into seven experimental groups (n = 7), according to the adhesive systems and photoactivation techniques of the materials inside the ceramic crown: Group 1: control (without adhesive system); Group 2: SBMP with no light-curing; Group 3: light-cured SBMP; Group 4: SB2 with no light-curing; Group 5: light-cured SB2; Group 6: SBU with no light-curing; Group 7: light-cured SBU. After the luting procedure with RelyX Ultimate, all specimens were submitted to thermocycling procedure (10,000 cycles). Sticks were then obtained for the analysis of microtensile bonding strength and nanohardness and elastic modulus of the resin componentes of the adhesive interface. Data were submitted to statistical analysis (ANOVA) and Fisher's test (α = 0.05). The results showed that the SBMP with no light-curing and SB2 with no light-curing groups had the lowest values ​​of bonding strength, while the highest values of the mechanical properties were achieved for the light-cured SBMP group, showing that the bonding strength as well as the mechanical properties were influenced by the interaction of materials. For mechanical properties analyzed, the light-curing of the adhesive systems didn’t present a statistically significant diference in the comparison between groups. In general, the application of adhesive systems on the silanized ceramic surface showed needless. Among the adhesives studied, SBU was the only system that showed effectiveness with or without previous light activation. For the other adhesive systems, SBMP and SB2, the previous light activation was necessary to optimize the bonding strength of the adhesive interface.
102

"Análise 'in vitro'da rugosidade superficial apresentada pelas porcelanas omega 900 e vitadur alpha após a utilização de três diferentes sistemas de polimento" / Omega 900 e vitadur alpha ceramics using three different polishing systems

Jesuina Lamartine Nogueira Araujo 25 June 2003 (has links)
RESUMO A qualidade da superfície de trabalhos cerâmicos que requer ajuste durante a sua adaptação ao remanescente dentário desperta a atenção durante os procedimentos odontológicos restauradores estéticos. Observa-se a necessidade freqüente de realizar desgastes superficiais nas restaurações cerâmicas, sendo que a preservação de uma superfície lisa é importante para as propriedades destes materiais, bem como para o seu comportamento clínico. Este trabalho propõe-se a avaliar a técnica com maior capacidade de polimento da superfície cerâmica asperizada, através da medição com ponta apalpadora de um rugosímetro, e utilizando o MEV para observações visuais com relação às técnicas empregadas. Para tal 80 corpos-de-prova foram confeccionados utilizando-se as porcelanas Omega 900 e Vitadur Alpha, constituindo quatro grupos experimentais: A – glaze (controle); B – polimento com borrachas abrasivas da DFL mais pasta para polimento da KOTA; C – polimento com borrachas abrasivas mais rodas de feltro mais pasta para polimento Porcelize (Cosmedent); D – polimento com borrachas abrasivas mais pasta porcelize mais discos Flexibuff mais pasta diamantada para brilho Enamelize (Cosmedent). Os dados receberam tratamento estatístico por meio da Análise de variância (ANOVA) e teste de Tukey, o qual indicou haver diferença estatisticamente significante entre os tipos de polimento para os quais as porcelanas foram submetidas, e na interação porcelana / polimento. Os resultados sugerem que todos os tratamentos polidores diminuem a rugosidade superficial das porcelanas em relação ao grupo controle e que dependendo da porcelana utilizada para cada técnica pode-se ter uma variação na rugosidade superficial. Quanto à observação pelo microscópio eletrônico de varredura houve uma correlação parcial entre este e os resultados obtidos pelo rugosímetro, pois aqui a porcelana Omega 900 mostrou-se mais polida no grupo controle, enquanto que na análise pelo rugosímetro apontou para a técnica polidora do Grupo D como sendo aquela que produziu uma superfície mais lisa para esta porcelana. Por outro lado, mostrou que o melhor polimento alcançado pela porcelana Vitadur Alpha foi através do polimento do Grupo C, o que está de acordo com os resultados obtidos pelo rugosímetro. / SUMMARY Aesthetic dentistry uses materials that can copy some lost caractheristics of the natural dentition, as color, mechanical resistance and smoothness.The better material for this are the ceramics. On the other hand, it is commum to have to grind them with diamond instruments for adjustment wich removes the glazed surfaces. This procedure can cause abrasion of the opposite teeth, plaque retention, injury of surrounding tissues and low aesthetics qualities. This study evaluated the roughness average in two dental ceramics, Omega 900 e Vitadur Alpha, that were grinding with diamond instruments after the glaze technique, and received three different polishing systems. The control group remained glazed until the end of the research. The groups were: Group A – control; Group B – grinding by fine and ultrafine points + polishing with DFL rubber points + KOTA diamond paste; Group C –grinding by fine and ultrafine points + polishing with rubber points + felt discs + Porcelize diamond paste (Cosmedent); Group D - grinding by fine and ultrafine points + polishing with rubber points + Porcelize + Flexibuff discs + Enamelize polishing paste (Cosmedent). To measure the roughness average in the samples it was used a profilometer Surftest SV-600 with the software Surfpack and the images were observed in the scanning electron microscopy (SEM) to comparation. The results received estatistical analysis using ANOVA and Tukey test (p˜0.05), and a significant tatistical difference was observed between the polishing systems , and in the porcelain/polishing interaction, which showed that all the polishing systems decreased the surface roughness of the porcelains after been grinding with diamond instruments, which was a better result than the control group. In the SEM analysis it was clear the presence of a partial relationship between the profilometer and that one, because here the Omega porcelain showed a more smoothness surface with the glazed treatment compaired with the others, differently from the profilometer analysis
103

Resistência à fratura de dentes que receberam restaurações adesivas de resina composta e porcelana / Fracture resistance of adhesively restored teeth with composite resin and ceramic restorations

Paulo Henrique Perlatti D'Alpino 21 December 2000 (has links)
Avaliou-se a resistência à fratura de dentes pré-molares superiores que receberam diferentes preparos cavitários (classe II-MOD) e restaurações diretas e indiretas de resina composta e restaurações indiretas de porcelana. Cinqüenta e seis dentes recém extraídos, hígidos, foram selecionados e divididos em 7 grupos: Grupo 1- hígidos, controle, não recebeu qualquer tratamento; Grupo 2- preparo cavitário com broca carbide n.º 245, produzindo cavidades retentivas, com ângulos internos arredondados, profundidade de 2 mm, abertura de istmo de metade da distância intercuspídea, caixa proximal com parede axial de 2 mm de extensão e 1,5 mm de profundidade, abertura de metade da dimensão vestíbulo-lingual, não sendo restaurado; Grupo 3 - recebeu somente preparo cavitário com ponta diamantada n.º 2136, produzindo cavidades com paredes divergentes para oclusal, ângulos internos arredondados, com as mesmas dimensões do preparo anterior, não sendo restaurado; Grupo 4 - recebeu o mesmo preparo que o grupo 2 e restaurou-se com resina composta aplicada na forma direta (Single Bond - 3M/ Z-250 – 3M); Grupo 5 - recebeu o mesmo preparo do grupo 3 e restaurou-se com resina indireta (Single Bond 3M/ Rely X- 3M/ Artglass-Kulzer); Grupo 6 - recebeu o mesmo preparo que o grupo 3, sendo restaurado com resina composta indireta (Single Bond 3M/ Rely X- 3M/ Targis- Ivoclar); Grupo 7 - mesmo preparo que o grupo 3, restaurado com restaurações indiretas de porcelana (Single Bond 3M; Rely X- 3M/ IPS Empress - Ivoclar). Submeteu-se os corpos de prova a testes de compressão axial, com um cilindro de aço (8 mm de diâmetro), acoplado a uma máquina de ensaios universal (Kratos), a uma velocidade de 0,5 mm/min, até que houvesse fratura de cúspide. Os valores obtidos foram os seguintes (em kgf): Grupo 1- 193,93 ± 24,46; Grupo 2- 108,56 ± 21,39; Grupo 3- 95,43 ± 17,73; Grupo 4- 147,65 ± 32,63; Grupo 5- 184,15 ± 56,49; Grupo 6- 183,81 ± 31,95; Grupo 7- 181,12 ± 40,49. Observou-se que os preparos cavitários reduziram significantemente a resistência dos dentes; não houve diferença significante na resistência dos dentes quando se comparou os diferentes tipos de preparo cavitário; os materiais restauradores contribuíram para que esses valores aumentassem, não se observando diferença estatística entre os grupos 4, 5, 6 e 7 e o grupo controle; houve um aumento significante na resistência quando se comparou os grupos 5, 6 e 7 (restaurações indiretas) em relação ao grupo 3 (preparado e não restaurado), o mesmo não sendo observado com o grupo 4 (restauração direta) em relação ao grupo 2 (preparado e não restaurado). / The purpose of this study was to evaluate the fracture resistance of teeth restored with direct and indirect restorations of composite resin and restored with indirect ceramic restorations. Fifty-six maxillary premolar teeth were selected and divided at random into seven groups; Group 1 (control): intact teeth; Group 2: MOD cavity preparations, ½ intercuspal distance, with rounded internal angles, convergent walls, unrestored; Group 3: MOD cavity preparations, ½ intercuspal distance, divergent walls; Group 4: same preparation as group 2, restored with direct composite resin (Single Bond/ Filtek Z250); Group 5: same as group 3, restored with indirect composite resin (Artglass-Kulzer/Single Bond/ Rely X); Group 6: same as group 3, restored with indirect composite resin (Targis-Ivoclar/ Single Bond/ Rely X); Group 7: same as group 3, restored with indirect ceramic restoration (IPS Empress – Ivoclar/ Single Bond/Rely X). The specimens were subject to a compressive axial load in a Universal testing machine at 0.5 mm/min by means of a steel bar (8 mm in diameter). The mean fracture strength obtained was (kgf): Group 1: 193,93 ± 24,46; Group 2: 108,56 ± 21,39 ; Group 3: 95,43 ± 17,73; Group 4: 147,65 ± 32,63; Group 5: 184,15 ± 56,49; Group 6: 183,81 ± 31,95; Group 7: 181,12 ± 40,49. There were no significant (p< 0.05) differences between intact teeth and teeth restored with indirect restorations. These results suggest that prepared teeth were significantly weaker than control group; teeth restored with direct and indirect composite resins were significantly more resistance to fracture than were similarly prepared but unrestored teeth. Restoring teeth with direct composite restoration increased the fracture resistance in relation to the control group, but was unable to strengthen them compared with unrestored teeth. These results showed that a bonded indirect restoration could be an ideal option for restoring teeth weakened by wide cavity preparation.
104

Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricos

Antônio Francisco Grando 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
105

A avaliação da confiabilidade e modo de falha de coroas de sistemas cerâmicos em função do desenho da infraestrutura e da aplicação de carga em cristas marginais / Evaluation of reliability and failure modes of ceramic crown systems depending on framework design and marginal ridge load application

Vinícius Pavesi Fardin 29 May 2013 (has links)
As excelentes propriedades mecânicas da zircônia fazem com que ela seja o material cerâmico de eleição para as coroas e próteses fixas posteriores. Porém, os problemas relacionados à fratura ainda persistem. A falta de suporte das infraestruturas às cerâmicas de revestimento é indicada como uma possível causa. O presente estudo visou avaliar através de testes laboratoriais se as infraestruturas metálicas e cerâmicas com o desenho convencional ou modificado apresentam diferença estatisticamente significante quanto à redução de complicações mecânicas, como fraturas e trincas na cerâmica de revestimento ao receberem cargas axiais nas cristas marginais de coroas de um primeiro molar inferior, por meio das seguintes hipóteses nulas: 1) a resposta à fadiga nas cristas marginais não aumentará a presença de danos nas coroas; 2) o desenho da I.E. não modificará a presença de danos nas coroas, independente do material utilizado. Quarenta coroas unitárias foram confeccionadas sobre preparos padronizados e divididos em 4 grupos: grupo I (infraestrutura convencional de Cobalto-Cromo); grupo II (infraestrutura modificada de Cobalto-Cromo); grupo III (infraestrutura convencional de Zircônia - IPS Emax ZirCAD); grupo IV (infraestrutura modificada de Zircônia - IPS Emax ZirCAD). Estas coroas foram submetidas ao teste de resistência à fadiga por meio da ciclagem dinâmica em água (106 ciclos ou até a fratura com carga variando de 30-300 N). Aplicou-se a carga inicial com o endentador cerâmico de dissilicato de lítio (IPS Emax Press) na crista marginal mesial, e após o término do ciclo, na distal, alternativamente. A ciclagem foi interrompida em intervalos de 125 mil ciclos a procura de danos com auxílio de estereomicroscopia. Ao final, as coroas fraturadas foram submetidas à microscopia eletrônica de varredura e as não fraturadas foram incluídas em resina epóxi e polidas sequencialmente para a análise dos danos. Cada corpo de prova recebeu escores de acordo com o tipo de falha apresentado. Utilizou-se o teste Kruskal-Wallis para verificar diferença estatística entre os grupos e o teste de Dunn para comparações múltiplas entre os grupos. Os resultados mostraram que há diferença estatisticamente significante entre os grupos, entretanto não houve diferença entre os grupos do mesmo sistema cerâmico. Concluiu-se que a hipótese 1 foi aceita e a 2 rejeitada. / The excellent mechanical properties of zirconia make it to be the material of choice for ceramic crowns and posterior fixed prostheses. However, problems still exist related to the chippings. The lack of framework support to ceramic veneer is indicated as a possible cause. This study aimed to evaluate through laboratory tests if metallic and ceramic framework with conventional or modified design show statistical difference in reducing mechanical complications, such as chipping or fracture of the ceramic veneer on receiving axial loads in marginal ridges of the first molar inferior crowns through the following null hypotheses: 1) the response to fatigue in marginal ridges will not increase the presence of damage to the crowns; 2) framework`s design will not modify the presence of damage to the crowns, regardless of the material used. Forty crowns were manufactured on standardized preparations and divided into four groups: group I (conventional framework Cobalt-Chromium), group II (modified framework Cobalt-chromium), group III (conventional framework Zirconia - ZirCAD IPS Emax) and group IV (modified framework Zirconia - IPS Emax ZirCAD). These crowns were subjected to cyclic loading in a fatigue machine and submerged in water (1.000.000 cycles or until the fracture - load range at 30-300 N). The initial load was applied on the mesial marginal ridge with indenter ceramic Lithium disilicate (IPS Emax Press), and after the end of the cycle, the distal alternatively. The cycling was interrupted at a prescribed number of loading cycles (125.000) and crowns were inspected for damage accumulation under a stereomicroscope. In the end, fractured crowns were submitted to scanning electron microscopy and crowns without fractures were embedded in epoxy resin and sequentially polished for the analysis of the damage. Each sample received scores according to the type of failure presented. Statistical analysis was carried out with Kruskal-Wallis test and multiple conparisons between groups were carried out with Dunn wed significant differences between groups, however there was no difference between the groups of the same ceramic systems. It was concluded that the first hypothesis was accepted and the second hypothesis was rejected.
106

Tratamento de superfície de porcelanas dentárias pela irradiação com laser de CO2 / Surface treatment of dental porcelains with CO2 laser

Ricardo Sgura 04 July 2013 (has links)
Este estudo teve como objetivo testar o laser de CO2 como um agente de tratamento de superfície de porcelanas dentárias. Material e Métodos: O estudo foi dividido em duas etapas: na primeira etapa, discos de porcelana (3,5 mm diam. x 2,0 mm espess.) das marcas VM7, VM9 e VM13 (VITA) foram sinterizados e tiveram uma de suas faces asperizadas por uma ponta diamantada 2134F para acabamento. Os espécimes foram então divididos em grupos de acordo com os seguintes tratamentos: nenhum (C), auto-glaze em forno (G) e irradiação com laser (L) de CO2 (Coherent, = 10,6 m, 35 W) de forma contínua com 40, 45 ou 50 W/cm2 nos tempos de 3, 4 ou 5 minutos (n=7). Nesta primeira etapa, as caracterizações das amostras constaram de: difratometria por raios-X, diferença de cor (Easyshade VITA), rugosidade superficial (Surftest 301, Mitutoyo) e análise visual por meio de esteromicroscopia e MEV. Um espécime de VM9 de cada grupo foi polido e levado a um exame por microscopia de força atômica (MFA). A segunda etapa consistiu na sinterização de discos das três porcelanas nas mesmas dimensões da etapa anterior, porém submetidos a um polimento de uma das superfícies com soluções diamantadas de granulação decrescente até 1 m. Os grupos testados foram os mesmos da primeira etapa, com exceção dos grupos irradiados com 40W/cm2. As caracterizações que se seguiram foram (n=10): microdureza Vickers, tenacidade à fratura, porosidade superficial, razão de contraste (RC) e capacidade de mascaramento (CM). Resultados: A rugosidade de espécimes asperizados foi diminuída pela aplicação do laser nas irradiâncias de 45 e 50 W/cm2, similar ao auto-glaze em forno, sem alteração de cor perceptível para a quase totalidade dos grupos irradiados. Houve um aumento do conteúdo cristalino das porcelanas VM9 e VM13 após a irradiação com o laser. As micrografias (MEV) demonstraram padrão de superfície homogêneo para os espécimes dos grupos irradiados a 50 W/cm2 e G. Os resultados da segunda etapa apontaram para alterações na microdureza e tenacidade à fratura na dependência da marca comercial e das irradiâncias estudadas. Quanto à porosidade, as porcelanas VM7 e VM13 apresentaram um aumento na fração volumétrica de poros, enquanto a porcelana VM9 irradiada apresentou-se semelhante a G. As médias de RC e CM indicaram um aumento na opacidade das porcelanas VM7 e VM13 irradiadas com o laser. Conclusão: Em condições específicas, o laser de CO2 é capaz de produzir uma lisura de superfície semelhante ao auto-glaze, com pequenas alterações nos aspectos ópticos e mecânicos. As diferentes marcas comerciais de porcelana apresentaram comportamentos distintos em relação aos tratamentos aplicados. / Glazing porcelain is an important procedure in dentistry that leads to surface smoothness, to less plaque accumulation and to brightness, especially after a chair side adjustment. Despite a good absorption of CO2 laser wavelength by dental porcelain it has not yet been tested as an alternative to oven glaze. Aim: This study tested CO2 laser as a heat source in surface treatment of dental porcelains. Material and Methods: This study was divided in two stages: at the first stage porcelain discs (VM7, VM9, VM13 VITA; 3.5 diam. x 2.0 mm thickness) were sintered, machined and had one of their sides grounded by a diamond bur (2134F KG Sorensen) simulating a chair side adjustment in clinical office. Specimens were then divided into groups according to treatment: no treatment (C); auto-glazed in conventional furnace (G) and submitted to CO2 continuous laser irradiation (Coherent, = 10.6 m; output power = 35 W, 0.5 cm laser beam) in 40, 45 or 50 W/cm2 for 3, 4 or 5 minutes (n=7). Specimens were supported by a ceramic refractory. At this first stage, the characterization consisted of X-ray diffraction (RU-200B, Rigaku), color difference (E) (Easyshade VITA), roughness (Surftest 301, Mitutoyo) and analysis of images achieved by stereomicroscopy (SZ61, Olympus) and SEM (Stereoscan 440, LEO). A VM9 specimen of each group had one of their side polished and was submitted to atomic force microscopy (AFM) Nanoscope IIIA (Veeco). In the second stage discs with the same dimension described above were sintered and polished with diamond solutions (Ecomet 3; 1 m). The same groups were tested except 40W/cm2 irradiance. Specimens were submitted to the following characterizations (n=10): Vickers microhardness test, fracture toughness by indentation fracture (HMV, Shimadzu), surface porosity (HMV, Image J software), contrast ratio (CR) and masking ability (MA) (CM-3770d, Konica Minolta). Results from both stages were submitted to one-way-ANOVA or Kruskall-Wallis test. A post-hoc Tukey test was applied when necessary ( = 0.05). Results: Ground specimens showed a reduction in roughness after laser irradiation (45 and 50 W/cm2), comparable to oven-glazed specimens with almost no color change. SEM images presented similarity between a irradiated group (50W/cm2) and G. AFM test revealed the formation of long rounded peaks and long valleys after laser exposition. Second stage results pointed to changes in microhardness and fracture toughness of irradiated specimens depending on the porcelain and irradiance tested. Regarding porosity, after laser exposition, porcelain VM7 and VM13 presented an increase in pores (area fraction) for the majority of groups while VM9 porcelain didnt show any increase in porosity after laser incidence. CR and MA means pointed to an increase in porcelain opacity to irradiated specimens of VM7 and VM13. Conclusion: Under specific conditions CO2 laser was able to produce a surface smoothness similar to auto-glaze, despite punctual changes in some optical and mechanical properties. The different brands presented distinct effects after laser heat treatment.
107

Avaliação in vitro da resistência ao cisilhamento de três agentes cimentantes em porcelana feldspática / Shear bond strength in vitro evaluation of three ciments in feldspathic porcelain

Ivonne Mariel Tavarez Vasquez 23 November 2009 (has links)
O presente estudo teve como objetivo comparar as resistências adesivas de três cimentos, entre dentina bovina e uma porcelana (Star Light Ceram) através de ensaio de cisalhamento em dois períodos de tempo. Foram utilizados incisivos bovinos incluídos numa matriz com resina epóxica. Cilíndros de porcelana (5 mm de altura e 6 mm de diâmetro) foram confeccionados. Foram confeccionados 10 corpos de prova para cada condição experimental. Os grupos foram divididos em: cimento resinoso RelyX ARC; cimento ionômero de vidro modificado por resina; cimento resinoso U100. Os dois primeiros materiais foram condicionados e receberam o seguinte tratamento: ácido fluorídrico por 2 min sobre a porcelana. Lavado e secado, foi aplicado uma camada fina de silano e logo aplicação do sistema de cimentação. A dentina bovina recebeu o seguinte tratamento: condicionamento com acido fosfórico a 35% por 20 s. e sistema adesivo Adper SingleBond 2. Os espécimes foram armazenados em água deionizada a 37° C por 24 horas ou 7 dias . Os espécimes foram submeidos a esforços de cisalhamento em uma máquina universal de ensaios. Os resultados foram submetidos à análise de variância a um critério (=0,05) e teste de Tukey. Houve diferença entre os cimentos estudados. O tratamento superficial da porcelana influenciou a resistência adesiva, porém não houve diferença significante entre os tempos de armazenamento. O cimento resinoso dual RelyX ARC com tratamento de superfície da porcelana apresentou maior resistência adesiva. / The present study had the aim to compare shear bond strengths of three cements used in bovine dentin and porcelain (Star Light Ceram) throught shear test in two periods. Bovine incisors were included in epoxic resin. Porcelain cylinders (5mm height and 6mm diameter) were prepared. 10 samples for each experimental condition were prepared. The groups were divided in: resin cement ARC; resin modified glass ionomer cement; self-adhesive cement U100. The first two materials were conditioned and received the following treatment: the porcelain received hidrofluoridric acid for 2min, rinsed and dried, with a thin silane layer being applied, before cementation; the dentin was conditioned with 35% phosphoric acid for 20s before the adhesive Adper SingleBond 2 application. Samples were stored in deionized watee at 37°C for 24h or 7 days. Samples were evaluated in shear in a universal testing machine. The results were analysed with one way analysis of variance (=0.05) and Tukeys test. There were differences between studied cements. The porcelain surface treatment influenced shear bond strength, however there were no significant differences between storage periods. The dual cured resin cement RelyX ARC with porcelain surface treatment showed higher shear bond strength.
108

Avaliação in vitro da resistência ao cisilhamento de três agentes cimentantes em porcelana feldspática / Shear bond strength in vitro evaluation of three ciments in feldspathic porcelain

Tavarez Vasquez, Ivonne Mariel 23 November 2009 (has links)
O presente estudo teve como objetivo comparar as resistências adesivas de três cimentos, entre dentina bovina e uma porcelana (Star Light Ceram) através de ensaio de cisalhamento em dois períodos de tempo. Foram utilizados incisivos bovinos incluídos numa matriz com resina epóxica. Cilíndros de porcelana (5 mm de altura e 6 mm de diâmetro) foram confeccionados. Foram confeccionados 10 corpos de prova para cada condição experimental. Os grupos foram divididos em: cimento resinoso RelyX ARC; cimento ionômero de vidro modificado por resina; cimento resinoso U100. Os dois primeiros materiais foram condicionados e receberam o seguinte tratamento: ácido fluorídrico por 2 min sobre a porcelana. Lavado e secado, foi aplicado uma camada fina de silano e logo aplicação do sistema de cimentação. A dentina bovina recebeu o seguinte tratamento: condicionamento com acido fosfórico a 35% por 20 s. e sistema adesivo Adper SingleBond 2. Os espécimes foram armazenados em água deionizada a 37° C por 24 horas ou 7 dias . Os espécimes foram submeidos a esforços de cisalhamento em uma máquina universal de ensaios. Os resultados foram submetidos à análise de variância a um critério (=0,05) e teste de Tukey. Houve diferença entre os cimentos estudados. O tratamento superficial da porcelana influenciou a resistência adesiva, porém não houve diferença significante entre os tempos de armazenamento. O cimento resinoso dual RelyX ARC com tratamento de superfície da porcelana apresentou maior resistência adesiva. / The present study had the aim to compare shear bond strengths of three cements used in bovine dentin and porcelain (Star Light Ceram) throught shear test in two periods. Bovine incisors were included in epoxic resin. Porcelain cylinders (5mm height and 6mm diameter) were prepared. 10 samples for each experimental condition were prepared. The groups were divided in: resin cement ARC; resin modified glass ionomer cement; self-adhesive cement U100. The first two materials were conditioned and received the following treatment: the porcelain received hidrofluoridric acid for 2min, rinsed and dried, with a thin silane layer being applied, before cementation; the dentin was conditioned with 35% phosphoric acid for 20s before the adhesive Adper SingleBond 2 application. Samples were stored in deionized watee at 37°C for 24h or 7 days. Samples were evaluated in shear in a universal testing machine. The results were analysed with one way analysis of variance (=0.05) and Tukeys test. There were differences between studied cements. The porcelain surface treatment influenced shear bond strength, however there were no significant differences between storage periods. The dual cured resin cement RelyX ARC with porcelain surface treatment showed higher shear bond strength.
109

"Influência do pH de armazenamento no crescimento subcrítico de trincas de porcelanas odontológicas com diferentes microestruturas" / Influence of pH of storage in the subcritical growth of trincas of odontológicas porcelains with different microstructures

Pinto, Marcelo Mendes 05 July 2006 (has links)
O objetivo do trabalho foi determinar o efeito do pH de armazenamento (pH 3,5; 7,0 e 10,0) nos parâmetros de crescimento subcrítico (n e ? f0) de duas porcelanas odontológicas com diferentes microestruturas (com e sem leucita). A hipótese testada foi a de que o pH do meio afeta os parâmetros de crescimento subcrítico dos dois materiais. Duas porcelanas feldspáticas foram avaliadas: 1) Ultropaline Dentina (UD), JenDental/Ucrânia; 2) Veneer Material 7 (VM7), Vita/Alemanha. A porcelana UD é composta de matriz vítrea com dispersão de partículas de segunda fase de leucita, enquanto a porcelana VM7 apresenta exclusivamente fase vítrea. Espécimes em forma de disco com características específicas (diâmetro e espessura) foram sinterizados com os dois materiais seguindo o ciclo proposto pelos fabricantes. Os espécimes foram armazenados em diferentes soluções com pH específico (3,5; 7,0 e 10,0) por 10 dias antes de serem testados. Os parâmetros de fadiga foram obtidos pelo método de fadiga dinâmica utilizando o ensaio de resistência à flexão biaxial (“piston on three balls") com cinco taxas constantes de carregamento (0,01; 0,1; 1; 10 e 100 MPa/s). A tenacidade à fratura e a dureza foram avaliadas pelo método da fratura por indentação (IF). A microestrutura dos materiais foi analisada por meio de microscopia eletrônica de varredura, difração de raios X e análise química por fluorescência de raios X. O efeito do pH no coeficiente de susceptibilidade ao crescimento subcrítico (n) foi diferente para os dois materiais estudados. Os resultados mostraram que, para a porcelana vítrea (VM7), o valor de n não variou significativamente em função do pH. Para a porcelana com leucita (UD), houve uma diminuição do valor de n quando a armazenagem foi feita em pH 3,5. O efeito do pH no parâmetro escalar (? f0) também foi diferente para os dois materiais. Para a porcelana VM7, tanto o pH ácido como o básico resultaram em menores valores de resistência em relação ao pH neutro. Para a porcelana UD, somente a armazenagem em pH básico resultou em queda do valor de ? f0. Os valores de dureza dos dois materiais diminuíram conforme o pH foi aumentado, porém, somente a diferença entre o grupo armazenado a seco e o grupo armazenado em pH 10 foi estatisticamente significativa para as duas porcelanas. Com relação à tenacidade, o pH não influenciou significativamente nas médias obtidas para os dois materiais. Com base nos resultados foi possível concluir que o efeito pH do meio de armazenamento no crescimento subcrítico de porcelanas dontológicas varia de acordo com a microestrutura do material. / The objective of the study was to determine the effect of the pH of the storage medium (pH 3,5; 7,0 e 10,0) on the fatigue parameters (n and ? f0) of two dental porcelains with different microstructures (with and without leucite). The hypothesis tested was that the pH affects the fatigue parameters of both materials. The dental porcelains tested were: 1) Ultropaline Dentin (UD), JenDental/Ucraine; 2) Veneer Material 7 (VM7), Vita/Germany. UD contains leucite and VM7 is only vitreous. Disc specimens were produced with both materials following manufacturers’ firing cycles. The specimens were stored in water solutions with different pHs (3,5; 7,0 e 10,0) for 10 days and after that the fatigue parameters were obtained by means of the dynamic fatigue test. Hardness and fracture toughness were determined by means of the indentation fracture technique. Microstructural analysis of the materials was also carried out. The effect of the pH in the fatigue parameters was different for the two materials tested. The results showed that, for VM7, the n value did not vary as a function of the pH. For porcelain UD, the n value was lower when the specimens where stored in pH 3,5. The parameter ? f0 was also affected by the pH. For both materials, the storage in basic pH resulted in a decrease in the ? f0 value. The hardness of both materials decreased with the increase in the pH of the storage media, and fracture toughness was not affect by the pH. Based on the results, it was possible to conclude that the effect of the pH (of the storage media) on the fatigue parameters of the dental porcelains studied varied according to the porcelain’s microstructure.
110

Efeito da neutralização do ácido fluorídrico, limpeza sônica dos precipitados e da cimentação sobre a resistência à flexão de uma cerâmica vítrea /

Saavedra, Guilherme de Siqueira Ferreira Anzaloni. January 2008 (has links)
Resumo: O objetivo deste trabalho foi avaliar cinco hipóteses: a) o condicionamento ácido diminui a resistência à flexão de uma cerâmica feldspática; b) a cimentação aumenta os valores de resistência à flexão de uma cerâmica feldspática; c) o processo de neutralização dos precipitados do ácido fluorídrico diminui os valores de resistência à flexão de uma cerâmica feldspática; d) a limpeza sônica (ultra-som) com água deionizada dos precipitados do ácido fluorídrico, formados sobre a superfície cerâmica após o condicionamento ácido, aumenta os valores de resistência à flexão de uma cerâmica feldspática; e) a associação entre o processo de neutralização dos precipitados do ácido fluorídrico e a limpeza sônica melhora a resistência à flexão de uma cerâmica feldspática. Foram confeccionadas 60 barras cerâmicas (20x4x1.2mm) (VM7 VITA Zahnfabrik). Cada barra cerâmica (1face) (exceção G1) foi condicionada (20s) com AF10% (Dentsply), seguida pela lavagem jato ar-água (60s) e secagem. Foram selecionadas aleatoriamente e separadas em 6 grupos(n=10): G1 - Controle (sem tratamento); G2 - condicionamento ácido apenas; G3 - o silano(Porcelain Primer,BISCO) foi aplicado na superfície cerâmica seguido da cimentação resinosa (Rely X ARC/3M); G4 - as barras foram imersas (40s) em solução supersaturada de bicarbonato de sódio, lavadas jato ar-água por (5s) e secas antes da aplicação do silano e cimentação; G5 - limpeza sônica (4min), silano e cimentação; G6 - associação da neutralização e limpeza sônica, seguido da silanização e cimentação. Após armazenagem (água destilada/sete dias a 37ºC), cada conjunto cerâmica/cimento) foi levado ao dispositivo de ensaio, sendo este acoplado em uma máquina de ensaios universal (EMIC) com célula de carga de 10Kgf, velocidade de 1,0mm/min e submetidos ao ensaio mecânico de flexão 3 pontos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate five hypotheses: a) hydrofluoric acid etching decreases the flexural strength of a feldspathic porcelain; b) cementation increases the flexural strength of a feldspathic porcelain; c) the neutralization process of hydrofluoric acid precipitates decreases the flexural strength of a feldspathic porcelain; d) hydrofluoric acid precipitates cleaning with ultrasonic bath in deionized water, formed on the ceramic surface after acid etching, increases flexural strength values of a feldspathic porcelain; e) the association between the neutralization process of the hydrofluoric acid precipitated and ultrasonic sonic cleaning improves the flexural strength of a feldspathic porcelain. Sixty ceramic bars (20x4x1.2mm) (VM7 VITA Zahnfabrik) were made and each one (1 surface) (except G1) was etched (20s) with HF10% (Dentsply), followed by water spray (60s) and drying. The specimens were randomly divided into 6 groups (n=10): G1 - Control (no treatment); G2 - hydrofluoric acid; G3 - silane(Porcelain Primer,BISCO) was applied on porcelain surface followed adhesive cementation (Rely X ARC/3M); G4 - the bars were immersed on a oversaturated sodium bicarbonate solution (40s), washed by water spray (5s) and drying before silane application and cementation; G5 - ultrasonic cleaning (4min), silane and cementation; G6 - association between neutralization and ultrasonic cleaning, followed by silanization and cementation. After storage (distillated water/ 7 days at 37ºC), each set (ceramic/cement) was carry to test device, which was mounted in universal test machine (EMIC) with a load cell of 10 Kgf, crosshead speed of 1,0mm/min, and submitted to the three-point bending mechanical test (immersed on water at 37 ºC). The flexural strength values and standard deviation (MPa) of the groups were: G1: 73,79±5,83a; G2: 60,65±10,07b; G3: 85,10±12,40a; G4: 80,91± ... (Complete abstract click electronic access below) / Orientador: Estevão Tomomitsu Kimpara / Coorientador: Tarcísio José de Arruda Paes Junior / Banca: Eduardo Piza Pellizzer / Banca: Maximiliano Piero Neisser / Banca: Rander Pereira Avelar / Banca: Rubens Nisie Tango / Doutor

Page generated in 0.0665 seconds