• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 190
  • 27
  • 27
  • 27
  • 27
  • 25
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 195
  • 123
  • 85
  • 78
  • 69
  • 44
  • 36
  • 34
  • 28
  • 22
  • 20
  • 18
  • 18
  • 18
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Efeito de diferentes espessuras, técnicas de aplicação e protocolos de resfriamento na resistência à fratura da cerâmica de cobertura aplicada sobre infraestrutura de y-tzp /

Lima, Júlia Magalhães da Costa. January 2014 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Francisco César / Banca: Susana Salazar Marocho / Banca: Renata Marques de Melo / Banca: Alexandre Luiz Souto Borges / Resumo: O objetivo desta pesquisa foi avaliar, in vitro, a influência do resfriamento, da técnica de aplicação e do efeito da espessura da cerâmica de cobertura na carga de fratura de coroas totalmente cerâmicas com infraestrutura de zircônia. Foram confeccionadas 100 infraestruturas de zircônia (Y-TZP) com 1,0 mm de espessura. 80 infraestruturas foram divididas em 8 grupos (n = 10) para confecção de 80 coroas de acordo com os fatores "técnica de aplicação" (estratificada e prensada), "espessura" (1 mm e 2 mm) e "protocolo de resfriamento" (lento e rápido) da cerâmica de cobertura. Com as outras 20 infraestruturas foram confeccionadas 20 coroas pela técnica CAD/CAM/Rapid Layer e divididas em 2 grupos (n = 10) de acordo com o fator "espessura da cerâmica de cobertura" (1 mm e 2 mm) e foi realizada Análise de Elementos Finitos. Todos os espécimes foram ciclados mecanicamente (200 N; 2 x 106 ciclos; 3,0 Hz; água/ 37 °C). A presença de chipping foi avaliada através de análise em estereomicroscópio após a ciclagem mecânica. Em seguida, todos os espécimes foram submetidos ao teste de resistência à fratura em compressão axial (0,5 mm/minuto; 10 kN). As coroas foram analisadas para determinar a possível origem da falha. Os dados (N) obtidos foram submetidos à análise estatística, com o Teste de Dunnett, teste t-Student, para a técnica CAD/CAM/Rapid Layer, e ANOVA 3-fatores e teste de Tukey para as demais técnicas. A carga de fratura das coroas confeccionadas pela técnica CAD/CAM/Rapid Layer, independente da espessura, foi menor em relação às outras duas técnicas (p < 0,05), mas houve diferença significativa entre as duas espessuras das coroas confeccionadas por esta técnica. Houve influência dos fatores resfriamento (p = 0,0058) e técnica de aplicação (p = 0,0001) na análise das técnicas estratificada e prensada. O resfriamento lento diferiu.... / Abstract: The aim of this study was to evaluate the in vitro influence of cooling protocols and application techniques and the effect of the thickness of veneering ceramics on the fracture resistance of prosthetic crowns. For this purpose, 100 'zirconia partially stabilized by yttrium oxide' frameworks (1 mm thick) were made. Eighty frameworks were divided into 8 groups (n = 10) according to the application technique (stratified or pressed), thickness (1 or 2 mm), and the cooling protocol (slow or fast) of the veneering ceramic. With the remaining 20 frameworks, 20 crowns were prepared by the CAD/CAM/Rapid Layer technique and were divided into 2 groups (n = 10) according to the veneering ceramic thickness (1 or 2 mm); these were also evaluated by Finite Element Analysis. All specimens were mechanically cycled (200 N, 2 x 106 cycles; 3.0 Hz; water at 37 °C). Chipping presence was evaluated by stereomicroscopy after mechanical cycling. All specimens were tested for compressive strength (0.5 mm/minute; 10 kN). We analyzed crowns to determine the possible beginning of the failures. Data, in N, were statistically analyzed with Dunnett's, t-test, 3-way ANOVA, and Tukey's tests. The fracture load of the CAD/CAM/Rapid Layer crowns was lower, regardless of ceramic thickness, when compared with the other two application techniques tested (p < 0.05). We observed an influence of the cooling protocol (p = 0.0058) and the application technique (p = 0.0001) in the analysis of stratified and pressed techniques. Slow cooling differed from rapid cooling in the pressed ceramic crowns; however, this difference was not observed for the stratified crowns, regardless of the thickness of the veneering ceramic. Failures in the CAD/CAM/Rapid Layer crowns began predominantly at the interface between the resin cement and veneering ceramic, resulting in delaminations of the veneering ceramic, while the other techniques .... / Doutor
132

Efeito de protocolos de jateamento na resistência à flexão e transformação de fase cristalina em cerâmicas de Y-TZP /

Turci, Priscilla Cristoforides Pereira. January 2014 (has links)
Orientador: Rubens Nisie Tango / Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: João Paulo Barros Machado / Banca: Paulo Francisco César / Banca: Alberto Noriyuki Kojima / Resumo: O objetivo deste estudo foi avaliar o efeito de diferentes protocolos de jateamento na resistência à flexão biaxial e transformação de fase cristalina de cerâmica policristalina de Y-TZP. Foram confeccionados 740 discos de zircônia estabilizada parcialmente por ítrio - Cercon®Zirconia (DENTSPLY Ceramco, EUA) e In Ceram 2000 YZ cubes (Vita Zahnfabrik, Alemanha) segundo a norma ISO 6872 (15 mm diâmetro x 2 mm espessura). As amostras foram jateadas com partículas de óxido de alumínio (30 μm) revestido por sílica (RocatecSoft - 3M ESPE) e divididas em 74 grupos (n = 10), incluindo-se os grupos controle (ausência de jateamento)(n = 10) para cada cerâmica, de acordo com os fatores: pressão de jateamento (2, 3 e 4 bar); ângulo formado entre a ponta do jateador e a superfície da cerâmica (45º, 60º, 90º); distância do microjateador à cerâmica (5 e 10 mm) e tempo de jateamento (15 s e 20 s). Foi realizado teste de resistência à flexão biaxial em máquina de ensaio universal (1 mm/min, 1000 kg). Os dados (MPa) foram submetidos a análise de variância e ao teste de Duncan. Parte das amostras (n=3) foram submetidas à difração por raios-X (DRX) para quantificação das fases cristalinas e à microcopia eletrônica de varredura (MEV) para análise da topografia superficial. Pressão (p = 0,00) afetou significativamente os resultados, porém tempo (p = 0,49), distância (p = 0,46) e angulação (p = 0,13) não afetaram a Cercon. Já para Vita YZ, a pressão (p = 0,00) foi estatisticamente significante, porém tempo (p=0,66), distância (p = 0,70) e angulação (p=0,14) não foram. Fase monoclínica foi encontrada nos grupos da Cercon (0 a 11%), enquanto para Vita YZ, nenhuma fase foi encontrada. Para Vita YZ, a pressão 3 bar teve maior resistência à flexão biaxial e 4 bar apresentou menor valor. Angulação de 45° associado a 2 bar foi a melhor combinação (1012,21 ± 108,36 MPa)... / Abstract: The aim of this study was to evaluate the effect of different sandblasting protocols on biaxial flexural strength and crystalline phase transformation in Y - TZP ceramic. 740 discs of Yttria-Partially-Stabilized Zirconia were made - Cercon ® Zirconia (DENTSPLY Ceramco, USA) and In Ceram 2000 YZ cubes (Vita Zahnfabrik, Germany) according to the standards of ISO 6872 (15 mm diameter x 2 mm thick) . The samples were sandblasted with aluminum oxide - coated silica 30 μm (Rocatec Soft - 3M ESPE ) and divided into 74 groups (n = 10 ) , according: pressure (2, 3 and 4 bar) ; nozzle angle (45°, 60°, 90°); nozzle distance (5 and 10 mm) and time (15 s and 20 s) . The biaxial flexural strength on universal testing machine (1mm/min, 1,000 kg) was performed. Data (MPa) were submitted to ANOVA and to Duncan's test (α = 0.05). Samples (n = 2) were subjected to X- ray diffraction to quantify crystalline phases. Pressure (p = 0.00) significantly affected the results, but deposition time (p = 0.49), nozzle distance (p = 0.46) and nozzle angles (p=0.13) did not affect to Cercon ceramic. Pressure (p = 0.00) affected significantly the results to Vita YZ, but deposition time (p = 0.66), nozzle distance (p = 0.70) and nozzle angles (p = 0.14) did not affect. Some monoclinical phase was achieved in Cercon groups (0 a 11%) and none for Vita YZ. For Vita YZ ceramic, 3 bar pressure had the biggest flexural strength value and 4 bar was the worst one and angle 45° associated to 2 bar were the best combination (1012.21 ± 108.36 MPa) compared to 4 bar (556.65 ± 117.41 MPa) (p < 0.001). EDS analysis demonstrated regular superficial grains. SEM images indicated grain size of 0.712 μm (Vita YZ), and 0.705 μm (Cercon). The Cercon density was 98% compared to the theoretical density of zirconia, while VITA YZ was 99% / Doutor
133

Restaurações cerâmicas minimamente invasivas executadas por cirurgiões dentistas com diferentes níveis de experiência profissional : estudo clínico cego, longitudinal e prospectivo /

Melo, Régis Alexandre da Cunha. January 2015 (has links)
Orientador: Eduardo Passos Rocha / Banca: Paulo Henrique dos Santos / Banca: Rodolfo Bruniera Anchieta / Resumo: Objetivo: Avaliar a influência da experiência profissional de cirurgiões-dentistas na taxa de sobrevida de restaurações cerâmicas delgadas cimentadas sobre dentes anteriores e/ou posteriores. Material e Método: Um total de 16 profissionais em nível de especialização realizaram tratamentos restauradores com cerâmica delgada, que foram divididos em quatro grupos (n=4) de acordo com o tempo de formação profissional - Grupo 1: recém-formados com até 2 anos de formados; Grupo 2: de 2 a 5 anos de formado; Grupo 3: de 5 a 10 anos de formado; Grupo 4: mais de 10 anos de formado. Todos os profissionais foram instruídos e treinados a seguirem o mesmo protocolo clínico de trabalho, embora desconhecessem os objetivos da pesquisa. Um único avaliador acompanhou os atendimentos clínicos realizados em 24 pacientes, totalizando 274 restaurações unitárias em dissilicato de lítio, sendo 158 na região anterior e 116 na posterior, distribuídas entre os arcos maxilar (186) e mandíbular (88). A espessura das cerâmicas variou entre 0,3 mm e 4,0 mm. As intercorrências ocorridas durante a execução dos protocolos clinicos, bem como os tempos de condicionamento ácido, de fotopolimerização e o tipo de cimento foram anotados. As restaurações foram cimentadas com diferentes cimentos em função da espessura da cerâmica, sendo: Rely X U200 (n=120), Rely X Veneer (n=95) e Variolink Veneer (n=58); totalizando 91 coroas totais, 137 facetas com preparo e 46 facetas sem preparo. As avaliações clínicas foram realizadas após a instalação das restaurações e nos controles de 30, 180, 360 dias posteriores à cimentação. Os parâmetros para a avaliação foram baseados nos critérios modificados do USPHS, adaptados ao estudo. Julgou-se insucesso quando houve fratura ou soltura das restaurações. As fraturas foram replicadas e submetidas à análise... / Abstract: Objective: To evaluate if the dentist experience can influence the survival rate of cemented anterior and/or posterior thin ceramic restorations. Materials and Methods: A total of 16 professionals with different expertise level with thin ceramic restorations were divided into four groups (n=4) - Group 1: up to 2 years of the graduation; Group 2: 2 to 5 years of graduation; Group 3: 5-10 years of graduation; Group 4: more than 10 years of graduation. All professionals have been educated and trained to follow the same clinical protocol, but were unaware of the research objectives. A single evaluator accompanied the clinical treatments performed in 24 patients, totaling 274 single restorations in lithium disilicate, 158 in the anterior region and 116 in the posterior distributed region among the arches, 186 in the maxillae and 88 in the jaw. The thickness of the ceramic varied between 0.3 mm and 4.0 mm. Minor complications that occurred during the execution of the protocols, the etching and the light curing times and the type of cement were recorded. The restorations were cemented with different cements according to the thickness of ceramic, which: Rely X U200 (n = 120), Rely X Veneer (n = 95) and Variolink® Veneer (n = 58); totaling 91 full crowns, 137 laminated with preparation and 46 laminated with no prepare. Clinical assessments were performed after the installation of the restorations and at the controls of 30, 180 and 360 days after the cementing period. The parameters for evaluation were based on the modified USPHS criteria, adapted to the study. It was deemed unsuccessful when there was fracture or loosening of the restorations. Fractures were replicated and submitted to fractographic analysis. Results: The least number of failures were observed in Group 2 (1 debonding), the largest number in Group 1 (5 fractures) and highest... / Mestre
134

Análise do comportamento da cor de restaurações cerâmicas sem metal avaliadas por diferentes métodos : estudo clínico prospectivo /

Martini, Ana Paula. January 2015 (has links)
Orientador: Eduardo Passos Rocha / Banca: Renato Herman Sundfeld / Banca: Carlos Marcelo Archangelo / Banca: Manoel Martin Junior / Banca: Paulo Henrique dos Santos / Resumo: Introdução: O processo de interpretação da cor em restaurações cerâmicas delgadas pré e pós-tratamento é um desafio. Os métodos de avaliação dos resultados são diversos e a literatura não é clara em apontar o mais eficaz e eficiente. A questão é ainda mais relevante diante da variação do cimento resinoso utilizado. Proposição: Após variar o tipo de cimento resinoso utilizado, o objetivo deste estudo foi avaliar o comportamento da cor de restaurações cerâmicas em dentes com demanda estética, ao longo de 1 ano após o tratamento, com o auxílio de diferentes métodos de acompanhamento (espectrofotômetro, fotografias, vídeos e avaliação clínica) em um estudo clínico longitudinal e prospectivo. Materiais e Métodos: Foram selecionados 28 pacientes, perfazendo um total de 204 dentes restaurados (89 facetas laminadas, 57 coroas totais ou parciais e 58 lentes de contato). 76 restaurações foram cimentadas com Rely X veneer, 71 com Variolink veneer e 57 com Rely X U200. Foram realizadas mensurações de cor com espectrofotômetro, fotografias digitais e vídeos gravados no decorrer do tratamento e em controles periódicos (inicial, 30 dias, 180 dias e 1 ano após a cimentação). Grupos formados por observadores externos (pacientes, alunos de 1º e último ano de graduação, pós-graduandos e especialistas) avaliaram, aleatoriamente, as imagens obtidas inicialmente e ao final do tratamento, segundo perguntas sobre a satisfação ou não com o resultado estético do caso. Resultados: Os dados obtidos com o espectrofotômetro foram submetidos a testes estatísticos que revelaram diferença significativa apenas entre os tempos avaliados, contudo, para todos os tipos de restauração foi observada estabilidade de cor após, no máximo, 180 dias da cimentação. Não houve diferença estatística entre a satisfação dos diferentes grupos... / Abstract: Introduction: The process of interpretation of color in thin ceramic restorations pre- and post-treatment is challenging. The evaluation methods of the results are diverse and literature is not clear in pointing out the most effective method. The question is even more relevant given the variation of the resin cement used. Purpose: After changing the type of resin cement used, the aim of this study was to evaluate the color behavior of ceramic restorations in teeth with aesthetic demand, over 1 year after treatment, with the help of different monitoring methods (spectrophotometer, photographs, videos and clinical assessment) in a longitudinal and prospective study. Materials and Methods: 28 patients were selected, for a total of 204 restored teeth (89 veneers, 57 crowns and 58 contact lenses). 76 restorations were cemented with Rely X veneer, 71 with Variolink veneer and 57 with Rely X U200. Color measurements were made with a spectrophotometer, digital photos and videos taken during treatment and periodic controls (initial, 30 days, 180 days and 1 year after cementation). Groups formed by outside observers (patients, students of 1st and last year of undergraduate, graduate students, and experts) evaluated, randomly, images obtained initially and after treatment, according to questions on satisfaction or not with the aesthetic outcome of the case. Results: The data obtained with the spectrophotometer were subjected to statistical tests which showed a significant difference only between the time periods; however, for all types of restoration, color stability was observed after a maximum of 180 days after cementation. There was no statistical difference between the satisfaction of different groups of outsiders observers with the aesthetic result of the cases for both the photos and for videos, although they videos have obtained the highest... / Doutor
135

Efeito da infiltração de sílica pelo método sol-gel na resistência à flexão de bicamadas de porcelana e Y-TZP /

Reis, Ana Flavia Nunes. January 2015 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Banca: Leonardo Buso / Resumo: O objetivo deste trabalho foi infiltrar sílica em uma cerâmica Y-TZP, avaliar seu efeito na resistência à flexão Biaxial, e na união com a porcelana feldspática. Para a análise da resistência à flexão foram confeccionados 180 discos de zircônia, 120 de 0,5mm e 60 com 1,2mm discos (14 mm de diâmetro). 90 discos foram infiltrados com sílica pelo método sol-gel em temperatura ambiente (n = 30). A espessura do disco foi de 1,2 mm para os espécimes controle (espécime sem porcelana, n = 30). O recobrimento por porcelana feldspática foi de duas espessuras (0,5mm e 1 mm) sobre a zircônia que tinha 0,5 mm. Os espécimes com porcelana foram polidos com lixas de carbeto de silício (SiC) de granulação # 400, 600, 800 e 1200. Obtivemos 6 grupos: dois monolíticos (ZR- Zircônia Monolítica sem infiltração e ZRI- Zircônia Monolítica Infiltrada) (controle) e quatro estratificados: ZRF 1,0 (0,5mm Zircônia coberta com 0,5 mm porcelana), ZRIF 1,0 (0,5 mm Zircônia infiltrada coberta com 0,5 mm de porcelana), ZRF 1,5 (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana) ZRIF 1,5- Zircônia infiltrada (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana). Após o ensaio de flexão biaxial em meio aquoso, foram determinados o módulo de Weibull (m) e resistência característica (σθ). Os fragmentos foram analisados em EDS, MEV, DRX e FTIR. A Dureza (H) e tenacidade a fratura foram analisadas pela nanoindentação, já o módulo elástico (E) por duas técnicas, nanoindentação e por impulso, e para avaliar a adesão entre a zircônia e a porcelana foi aplicado o Teste de Scratch. Foram modeladas 7 condições experimentais e analisados pelo método por elementos finitos. A zircônia monolítica infiltrada mostrou uma estrutura com grãos arredondados envoltos em uma matriz de sílica, e a presença de zircônia cúbica e tetragonal. O DRX revelou a formação de ZrSiO4 nos grupos infiltrados. Os grupos monolíticos... / Abstract: The objective was to infiltrate silica in a Y- TZP ceramics, evaluate its effect on resistance biaxial strenght, and the union with feldspathic porcelain. For the analysis of flexural strength were prepared zirconia discs 180, 120 and 60 of 0.5 mm to 1.2 mm disks (14 mm diameter). 90 discs were infiltrated with silica by the sol-gel method at room temperature (n = 30). The thickness of the disk was 1.2 mm for the samples control (no porcelain specimen, n = 30). The coating was feldspathic porcelain by two thicknesses (0.5 mm and 1 mm) of zirconia, which had 0.5 mm. Specimens with porcelain were polished with sandpaper silicon carbide (SiC) granulation # 400, 600, 800 and 1200. We obtained six groups: two monolithic (Zr-Zirconia Monolithic without infiltration and ZRI- Zirconia monolithic Infiltrated) (control) and four laminated ZRF 1.0 (0.5 mm zirconia covered with 0.5 mm porcelain), ZRIF 1.0 (0.5 mm infiltrated zirconia covered with 0.5 mm of porcelain), ZRF 1.5 (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain) ZRIF 1,5-infiltrated Zirconia (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain). After the biaxial bending test in an aqueous medium were determined Weibull modulus (m) and the characteristic strength (σθ). The fragments were analyzed by EDS, SEM, XRD and FTIR. The hardness (H) and fracture toughness were analyzed by nanoindentation, since the elastic modulus (E) by two techniques, nanoindentation and on impulse, and to evaluate the adhesion between the zirconia and porcelain was applied Scratch Test. 7 experimental conditions were modeled and analyzed by the finite element method. The infiltrated zirconia showed a monolithic structure with rounded grain wrapped in a silica matrix, and the presence of cubic and tetragonal zirconia. The XRD showed the formation of ZrSiO4 infiltrates in groups. The monolithic modules Weibull groups showed superior to ... / Mestre
136

Efeitos de lasers de alta potência na superfície de cerâmicas vítreas de dissilicato de lítio e sua resistência de união à dentina humana /

Feitosa, Fernanda Alves. January 2016 (has links)
Orientador: César Rogério Pucci / Banca: Rebeca Di Nicoló / Banca: Patrícia Moreira de Freitas / Banca: Taís Scaramucci Forlin / Banca: Symone Cristina Teixeira / Resumo:O objetivo desse estudo foi avaliar a eficiência da irradiação com lasers de alta potência e a influência da aplicação do silano previa ou posteriormente à irradiação com os lasers na resistência de união entre cerâmica vítrea de dissilicato de lítio, cimento resinoso e dentina humana. Foram confeccionados 50 espécimes troncocônicos de cerâmica (n=10), divididos aleatoriamente em 5 grupos: 1- ControleCondicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 2- Er:YAG - irradiação com laser Er:YAG (200 mJ e 10 Hz), seguido do condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 3- Silano + Er:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Er:YAG nos mesmo parâmetros do grupo anterior; 4- Nd:YAG - irradiação com laser Nd:YAG (120 mJ e 10 Hz), seguido de condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano, 5- Silano + Nd:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Nd:YAG nos mesmo parâmetros do grupo anterior. Após os tratamentos os espécimes cerâmicos foram cimentados com cimento resinoso de presa dual à superfície de dentina de 50 molares humanos incluídos em resina acrílica ativada quimicamente. Após armazenamento por 24 h foi realizado o ensaio de tração em máquina de ensaios universais com célula de carga de 10 KgF e velocidade constante de 1mm/min. Os dados obtidos foram submetidos à ANOVA 2-fatores e teste de Dunnet (α=5%). A análise dos padrões de fratura foram analisadas em estereomicroscopio. Adicionalmente foram confeccionados 15 espécimes em cerâmica no formato cilíndrico, submetidos aos mesmo tratamentos dos grupos anteriores (n=3) e utilizados para análise do ângulo de contato e análise em microscópio eletrônico de varredura. O teste de Dunnet mostrou diferenças... / Abstract:The aim of this study was to evaluate the efficiency of irradiation with high-power lasers and the influence of silane application before or after irradiation with lasers on the bond strength between lithium disilicate glass-ceramic, resin cement and human dentin. Fifty truncated-cones ceramic specimens (n=10) were randomly divided into 5 groups: Control- etching with hydrofluoric acid 10% for 1 min and application of silane; 2- Er - Er:YAG laser irradiation (200 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of silane; 3- Sil + Er - etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Er: YAG laser in the same parameters as the previous group; 4- Nd:YAG laser - irradiation with Nd: YAG laser (120 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of the silane, 5- Sil + Nd- Etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Nd: YAG laser on the same parameters as the previous group. After treatment, the ceramic specimens were cemented with dual cure resin cement to the dentin of 50 human molars included in acrylic resin. After storage for 24 h it was submitted to tensile test in a universal testing machine with 10 kgf load cell and constant speed of 1 mm/min. Data were submitted to ANOVA 2-way and Dunnet test (α = 5%). The analysis of fracture patterns were analyzed in stereomicroscope. In addition were made 15 ceramic specimens in cylindrical shape, subjected to the same treatment of the above groups (n = 3) and used for analysis of the contact angle analysis and scanning electron microscope. The Dunnet test showed significant differences between Control group (9.42 ± 2.27 MPa) and Er group (19.25 ± 3.7 MPa) and Sil + Er (14.11 ± 4.11 MPa). ANOVA 2-way (p <5%) for Laser Type (p <0.0001) and Technical of Silanization (p = 0.0002) showed significant differences for both factors, but not for their.. / Doutor
137

Cimentação de laminados cerâmicos : efeito de diferentes modos de fotoativação na estabilidade de cor e nas propriedades mecânicas de sistemas adesivos e cimentos resinosos /

Sahyon, Henrico Badaoui Strazzi. January 2017 (has links)
Orientador: Paulo Henrique dos Santos / Banca: Wirley Gonçalves Assunção / Banca: Anderson Catelan / Resumo: O objetivo deste estudo in vitro foi avaliar os efeitos de diferentes modos de fotoativação na nanodureza e módulo de elasticidade de sistemas adesivos e cimentos resinosos, assim como o efeito na estabilidade de cor de laminados cerâmicos. Os fatores em estudos foram: dois níveis de fotopolimerizadores (VALO - Ultradent; Radii-Cal - SDI) e três níveis de modo de ativação (sem polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico; polimerização prévia do sistema adesivo somente na superfície dental; e polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico). Na análise da estabilidade de cor o terceiro fator estudado foi o tempo de envelhecimento (252, 504 e 756 horas). Foram confeccionados 132 blocos de cerâmica (7x8x0,6mm) de dissilicato de lítio (IPS e-max CAD), os quais foram cimentados sobre o esmalte dentário dos dentes bovinos, distribuídos em 12 grupos de acordo com os materiais restauradores e métodos de procedimentos utilizados. Dois sistemas adesivos e cimentos resinosos foram utilizados (Single Bond Universal/RelyX Veneer- 3M/ESPE e Tetric N Bond/Variolink Veneer - Ivoclar Vivadent). As propriedades mecânicas de nanodureza e módulo de elasticidade foram mensuradas utilizando nanodurômetro (Anton Paar), sob ação de carga de 1000μN (n=3). A estabilidade de cor foi mensurada através do espectrofotômetro de reflexão ultravioleta visível UV-2450 (Shimadzu) antes e após a submissão das amo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this in vitro study was to evaluate the effects of different modes of photoactivation in the nanohardness and elastic modulus of resin cements and adhesives, as well as the effect on the color stability of ceramic laminates. The factors of the studies were: two levels of light curing units (VALO - Ultradent; Radii-Cal - SDI) and three modes of photoactivation (without prior curing of the adhesive system in the tooth surface and inside of the ceramic laminate, prior curing the adhesive system only in the tooth surface, and prior curing of the adhesive system in the tooth surface and within the ceramic laminate). In the analysis of color stability the third factor of the study was the aging time (252, 504 and 756 hours). One hundred and thirty two ceramic blocks (7x8x0.6mm) of lithium dissilicate (IPS e-max CAD) were made, which were cemented on the enamel of bovine teeth, and distributed into 12 groups according to the restorative materials (Single Bond Universal/RelyX Veneer - 3M/ESPE and Excite DSC/Variolink Veneer - Ivoclar Vivadent) and methods of procedures. The mechanical properties of nanohardness and elastic modulus were measured using a nanohardness tester (Anton Paar) under loaf of 1000 μN (n=3). Color stability was measured using a UV-2450 visible UV spectrophotometer (Shimadzu) before and after the submission of the UVB artificial accelerated aging samples (n=8). Data of color stability and mechanical properties were submitted to statistical testes o... (Complete abstract click electronic access below) / Mestre
138

Cinética de degradação de zircônias odontológicas com alta translucidez /

Prado, Pedro Henrique Condé Oliveira. January 2018 (has links)
Orientador: Renata Marques de Melo Marinho / Coorientador: Tiago Moreira Bastos Campos / Banca: Alexandre Luiz Souto Borges / Banca: Eliandra de Sousa Trichês / Resumo: Com o avanço da ciência e processamento de materiais, a zircônia odontológica deixou de ser um material opaco para apresentar certa translucidez, possibilitando a confecção de peças ultrafinas. Sabe-se que a água em contato com a superfície das zircônias convencionais acarreta na transformação de fase T-M e subsequente decréscimo de resistência, mas esses efeitos nas zircônias translúcidas ainda não foram explorados. Para avaliar, mapear e caracterizar os efeitos da cinética de envelhecimento acelerado em zircônias de alta translucidez, foram cortados 39 blocos de Y-TZP (VITA YZ, VITA HT, InCoris TZI) para cada zircônia comercial, onde posteriormente foram sinterizados (1530 ºC, 2h) e atribuídos a 13 grupos com 3 amostras cada: Um controle e 12 envelhecidos hidrotermicamente a 134 ºC com pressão constante de 2 bars por 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 e 140 horas. A análise em DRX foi utilizada para quantificar a transformação de fase da zircônia (tetragonal-monoclínica) em diferentes profundidades do material ao se trocar o ânodo do tubo irradiador (Cr, Co e Cu). Uma curva cinética de envelhecimento foi feita para cada profundidade para as 3 zircônias comerciais. Para avaliar os efeitos do envelhecimento hidrotermal nas propriedades mecânicas, 270 discos de Y-TZP foram cortados, 90 para cada tipo, sinterizados e atribuídos a 3 grupos: C-Controle; E1- envelhecido até 26h e E2- envelhecido até 140 horas. Os discos foram testados em uma máquina de teste universal (EMI... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To evaluate, map and characterize the effects of the accelerated aging kinetics of high translucency zirconias, this study was split into 2 parts: One part evaluating the superficial changes after in vitro hydrothermal aging and the second part aiming the effects of this aging on the mechanical properties of those ceramics. 117 Y-TZP (VITA YZ, VITA HT, InCoris TZI) blocks were cut, 39 for each commercial zirconia, sintered (1530 ºC, 2h) and assigned to 13 groups with 3 samples each: One being a control, aging-free group, and 12 groups that were prematurely aged hydrothermally at 134 ºC and constant pressure of 2 bars through 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 and 140 hours. XRD was used to quantify the amount of zirconia phase transformation (tetragonalmonoclinic) on different depths of the material by swapping the anode tube (Cr, Co, and Cu). An aging kinetic curve was made for each depth for the 3 commercial zirconias. To evaluate the effects of the hydrothermal aging on the mechanical properties, Y-TZP blocks were rounded to a cilindrical shape. 270 discs were cut, 90 for each kind, sintered as mentioned above and assigned to 3 groups: C-Control; E1- Aged through 26h and E2- Aged through 140h. Disks were then tested in a universal testing machine (EMIC) under a load of 1000 kg till fracture of the specimen and the surface was evaluated under SEM. The aging kinetics curves work similarly for all the YTZP used in this study, characterized by phase transformation asce... (Complete abstract click electronic access below) / Mestre
139

Determinação da tensão de falha de lascamento da porcelana de cobertura em prótese livre de metal utilizando análise de imagem /

Silva, Elielson Nóbrega da. January 2018 (has links)
Orientador: Marcos Yutaka Shiino / Coorientador: Alberto Noriyuki Kojima / Banca: Vinícius Anéas Rodrigues / Banca: Vivian Silveira dos Santos Bardini / Resumo: A introdução da zircônia na Odontologia deu-se pela necessidade de melhores propriedades mecânicas dos materiais cerâmicos, pois com a crescente demanda estética, os cerâmicos tornaram-se materiais de largo uso, devido às suas propriedades estéticas e mecânicas. Em busca dessas propriedades, vários estudos analisaram a taxa de sobrevivência de restaurações zircônia-porcelana, relatando como uma das causas de falha a fratura precoce da porcelana de cobertura e o aumento significativo nos relatos clínicos de lascamento da porcelana de recobrimento aplicada sobre "coping" de zircônia. Diante desse problema, o objetivo deste trabalho foi determinar a tensão de falha no lascamento a partir de casos de clínicos e experimentais pertinentes a esse fenômeno em próteses fixas livres de metal .Foram coletados dados de artigos dos últimos 15 anos, por meio das bases de dados Pubmed e Google Schoolar, sendo selecionados para essa revisão os que obtiveram melhor abordagem do assunto, dando ênfase às possíveis causas de falhas nas restaurações cerâmicas dos casos clínicos e os ensaios realizados, visando um melhor entendimento desse fenômeno, via análise quantitativa e qualitativa, para melhor utilização e aproveitamento desse material na Odontologia. Para determinação da tensão de falha, foi empregada a mecânica da fratura linear elástica e determinado o fator de correção da trinca com base nas dimensões da trinca.Com a presente pesquisa, nota-se que amplitude de tensão influencia no proce... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The introduction of zirconia in dentistry was due to the need for better mechanical properties of ceramic materials, because of an increasing aesthetic demand. Ceramics became widely used materials due to their aesthetic and mechanical properties. Aiming at these properties, several studies have analyzed the survival rate of zirconia-porcelain restorations, reporting as one of the causes of failure. Early porcelain fracture coverage and a significant increase in clinical reports of veneering porcelain applied over "coping "of zirconia. In view of this problem, the objective of this work was to determine the failure causes of chipping from clinical and experimental cases associated to this phenomenon in fixed metal free prostheses. Data from articles of the last 15 years were collected through the Pubmed and Google Schoolar databases. Those who obtained the best approach to the subject were selected for this analysis, emphasizing the possible causes of failures in the ceramic restorations of the clinical cases and the tests performed. Aiming for a better understanding of this phenomenon, via quantitative and qualitative analysis, to better use this material in dentistry. To determine the failure causes, linear elastic fracture mechanics were used and the crack correction factor was determined based on the crack dimensions. With the present research, it is noticed that stress amplitude influences in the fracture process, although it has not pointed exactly the cause of the frac... (Complete abstract click electronic access below) / Mestre
140

ESTUDO DA INCORPORAÇÃO DE VIDRO DE PARA-BRISA EM MASSA DE PORCELANA SILICOSA E ALUMINOSA

Santos, Araldo Augusto Tisque dos 08 August 2012 (has links)
Made available in DSpace on 2017-07-21T20:42:38Z (GMT). No. of bitstreams: 1 Araldo Augusto Tisque dos Santos.pdf: 3494228 bytes, checksum: 10aa5475f02c7ee4a3913a8571815ebc (MD5) Previous issue date: 2012-08-08 / The glass is not a biodegradable material, which causes an environmental problem when it is discarded. However, it is a material that can be 100% recycled, or even re-used, but the laminated glass (glass windshields) is not accepted for recycling, this because it is a glass of low particle size and also by the difficulty of separating the glass polymer film, while this type of glass consisting of two or more layers of glass held together by one or more layers of a polymer called polyvinyl butyral (PVB). Thus it is necessary to find alternative means which allow recycling. In this thesis was studied the possibility of incorporating laminated glass in the ceramic bodies of siliceous and aluminous porcelain, replacing feldspar which acts as a flux these two ceramic bodies. The objective of this research is to verify the changes that the incorporation of glass windshields because the glassy phase of siliceous and aluminous porcelain and reflections that these changes have on the ceramic properties. Was chosen for this particle sizes of two glass laminate, and a thin, rough and added to another ceramic body in amounts of 5%, 10% and 15%, by weight replacing the same amount of feldspar. The powders of these mixtures were pressed and sintered at three different temperatures. Sintered porcelains were characterized through measurements of porosity, bulk density, water absorption, modulus of rupture by three point bending, X-ray diffraction, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS). The compositions siliceous and aluminous porcelain were introduced laminated glass of finer showed very similar results to those of composition without addition of laminated glass. / O vidro não é um material biodegradável, causando um problema ambiental quando o mesmo é descartado. Entretanto é um material que pode ser 100% reciclado, ou até mesmo reutilizado, mas o vidro laminado (vidro de para brisas) não é aceito para a reciclagem, isto por se tratar de um vidro de baixa granulometria e também pela dificuldade de separar o vidro do filme polimérico, sendo que este tipo de vidro composto por duas ou mais camadas de vidro unidas por uma ou mais camadas de um polímero chamado de polivinil butiral (PVB). Assim se torna necessário encontrar meios alternativos que permitam a reciclagem desse material. Nessa dissertação foi estudada a possibilidade da incorporação do vidro laminado nas massas cerâmicas de porcelana aluminosa e silicosa, substituindo o feldspato que atua como fundente nessas duas massas cerâmicas. O objetivo dessa pesquisa é de verificar as mudanças que a incorporação do vidro de para brisas causa na fase vítrea da porcelana aluminosa e silicosa e os reflexos que essas mudanças apresentam nas propriedades cerâmicas. Para isso foi escolhido duas granulometrias de vidro laminado, sendo uma fina e outra grosseira e adicionadas à massa cerâmica nas quantidades de 5%, 10% e 15%, em peso substituindo a mesma quantidade de feldspato. Os pós dessas misturas foram prensados e sinterizados em três temperaturas diferentes. As porcelanas sinterizadas foram então caracterizadas através de medidas de porosidade aparente, densidade aparente, absorção de água, módulo de ruptura por flexão de três pontas, difração de raios X, microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS). As composições de porcelana aluminosa e silicosa que foram introduzidos o vidro laminado de granulometria fina apresentaram resultados muito próximos aos das de composição sem adição de vidro laminado.

Page generated in 0.129 seconds