• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 190
  • 27
  • 27
  • 27
  • 27
  • 25
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 195
  • 123
  • 85
  • 78
  • 69
  • 44
  • 36
  • 34
  • 28
  • 22
  • 20
  • 18
  • 18
  • 18
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

EFEITO DA ESPESSURA DA CERÂMICA DE INFRAESTRUTURA E COBERTURA DE UM SISTEMA A BASE DE DISSILICATO DE LÍTIO NA SUA COR E OPACIDADE

Bueno, Rodrigo Salbego 28 August 2013 (has links)
The aim of this study was to determine the influence of substruture and veneer ceramic thickness variation, of a lithium disilicate all ceramic system, in its color and opacity. The sample was composed by of 12 specimens, disc shaped, with 12mm in diameter and 4mm in thickness (2mm of substruture ceramic and 2mm of veneer ceramic). Sequential wear of 0,5mm were performed in each specimen, initially in the substruture ceramic and subsequenty in the veneer ceramic, upto 1.0mm of total final thickness (0,5mm of substruture and 0,5mm of veneer ceramic). The L*, a* and b* parameters of the CIELab system and the opacity percentage (Op) were measured using an spectrophotometer at base line and after each wear. The opacity percentage variation (ΔOp) and color variation (ΔE) among groups were obtained. Data were tabulated and analysed at 5% significance level. All the evaluated color parameters showed significant difference among groups. OP decreased with ceramic decreasing thickness, with greater changes in the venner ceramic groups. ΔE was higher when comparing groups with lower ceramic thickness. Furthermore, ΔOP was directly proportional to ΔE. It could be concluded that color and opacity are influenced by the thickness variation of the all ceramic system tested. The opacity percentage was more dependent of the veneer ceramic than the substruture ceramic. The opacity variation is correlated to color variation. / O objetivo deste estudo foi determinar a influência da variação de espessura da cerâmica de infraestrutura e cobertura, de um sistema cerâmico a base de dissilicato de lítio, em sua cor e opacidade. A amostra consistiu de 12 corpos de prova (cps), confeccionados em forma de disco, com 12 mm de diâmetro e 4mm de espessura (2mm de cerâmica de infraestrutura e 2mm de cobertura). Desgastes sequenciais de 0,5mm foram realizados nos cps, primeiramente na cerâmica de infraestrutura e posteriormente na de cobertura até a espessura final total de 1,0mm (0,5mm de infraestrutura e 0,5mm de cobertura). Os parâmetros L*, a* e b* do sistema CIEL*a*b* e o Percentual de Opacidade (Op) foram medidos por um espectrofotômetro no período inicial e após cada desgaste. A variação do Percentual de Opacidade (ΔOp) e a variação de cor (ΔE) entre os grupos foram obtidos. Os dados foram tabulados e analisados com nível de significância de 5%. Todos os parâmetros avaliados apresentaram diferença média significativa entre os grupos. O Op diminuiu com a espessura cerâmica, apresentando maiores variações nos grupos correspondentes a cerâmica de cobertura. O ΔE entre os grupos mostrou-se maior quando comparamos os grupos de menor espessura cerâmica. Além disso, ΔOp apresentou-se diretamente proporcional a ΔE. Concluiu-se que a cor e a opacidade são influenciadas pela variação de espessura do sistema cerâmico testado. O Percentual de Opacidade foi mais dependente da cerâmica de cobertura do que da de infraestrutura. A variação de opacidade está correlacionada com a variação de cor.
152

Efeito da aplicação e fotoativação prévia de sistemas adesivos em cerâmica de dissilicato de lítio: análise da resistência de união e das propriedades mecânicas dos componentes resinosos da interface adesiva / Effect of the application and photocuring of adhesive systems on lithium dissilicate ceramics: analysis of the bonding strength and mechanical properties of resin components of the adhesive interface

Proni, Ana Teresa Maluly [UNESP] 10 August 2017 (has links)
Submitted by ANA TERESA MALULY PRONI null (atmaluly@gmail.com) on 2017-08-23T23:42:10Z No. of bitstreams: 1 Dissertação final PG.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-25T14:07:17Z (GMT) No. of bitstreams: 1 proni_atm_me_araca.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) / Made available in DSpace on 2017-08-25T14:07:18Z (GMT). No. of bitstreams: 1 proni_atm_me_araca.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) Previous issue date: 2017-08-10 / O objetivo deste estudo foi analisar o efeito da aplicação e da fotoativação prévia de diferentes sistemas adesivos em superfície de cerâmica de dissilicato de lítio, com ênfase na resistência da união cimento-cerâmica e na análise das propriedades mecânicas nanodureza e módulo de elasticidade dos diferentes adesivos e do cimento resinoso utilizado. Quarenta e nove blocos de resina composta (Z350XT A6B) e de blocos cerâmicos (e.max CAD LT D3) foram divididos em sete grupos experimentais (n=7), os quais foram cimentados entre si de acordo com o sistema adesivo utilizado na superfície dos blocos cerâmicos: Grupo 1: sem adesivo; Grupo 2: Adper™ Scotchbond™ Multi-Purpose Adhesive (SBMP) sem fotoativação; Grupo 3: SBMP com fotoativação; Grupo 4: Adper™ Single Bond 2 (SB2) sem fotoativação; Grupo 5: SB2 com fotoativação; Grupo 6: Single Bond Universal (SBU) sem fotoativação; Grupo 7: SBU com fotoativação. Em todos os grupos experimentais, o cimento resinono utilizado foi o RelyX Ultimate. Após 24 horas do processo de cimentação, todos os conjuntos foram submetidos à termociclagem entre 5°C e 55°C, com tempo de permanência de 28 segundos e tempo de transferência de 2 segundos para envelhecimento (10.000 ciclos). Os conjuntos foram então seccionados para obtenção de palitos para análise da resistência de união e das propriedades mecânicas de nanodureza e módulo de elasticidade dos adesivos e do cimento resinoso utilizado. Os dados foram submetidos à ANOVA e teste de Fisher (α = 0,05). Os resultados mostraram que os grupos SBMP e SB2 sem fotoativação apresentaram os menores valores de resistência de união, enquanto que para as propriedades mecânicas de nanodureza e módulo de elasticidade os maiores valores foram encontrados somente para o grupo SBMP com fotoativação, mostrando que a resistência de união foi influenciada pela interação dos materiais utilizados. Para as propriedades mecânicas analisadas, a fotoativação prévia dos sistemas adesivos não apresentou diferença estatisticamente significante na comparação entre os grupos. De acordo com os resultados obtidos, concluiu-se que a aplicação de sistemas adesivos na superfície silanizada da cerâmica se mostrou desnecessária. Dentre os adesivos estudados, o SBU foi o único material que se mostrou eficaz com ou sem fotoativação prévia. Para os demais adesivos estudados, SBMP e SB2, a fotoativação prévia se mostrou necessária para otimizar a resistência de união da interface adesiva estudada. / The aim of this study was to analyze the effect of the application and previous photoactivation of different adhesive systems on lithium dissilicate ceramics, with emphasis on the bond strength of cement-ceramic interface and the analysis of the mechanical properties (nanohardness and elastic modulus) of different adhesives systems and resin cement used. Forty-nine composite resin blocks (Z350XT A6B) and ceramic tablets (e.max CAD LT D3) which were divided into seven experimental groups (n = 7), according to the adhesive systems and photoactivation techniques of the materials inside the ceramic crown: Group 1: control (without adhesive system); Group 2: SBMP with no light-curing; Group 3: light-cured SBMP; Group 4: SB2 with no light-curing; Group 5: light-cured SB2; Group 6: SBU with no light-curing; Group 7: light-cured SBU. After the luting procedure with RelyX Ultimate, all specimens were submitted to thermocycling procedure (10,000 cycles). Sticks were then obtained for the analysis of microtensile bonding strength and nanohardness and elastic modulus of the resin componentes of the adhesive interface. Data were submitted to statistical analysis (ANOVA) and Fisher's test (α = 0.05). The results showed that the SBMP with no light-curing and SB2 with no light-curing groups had the lowest values ​​of bonding strength, while the highest values of the mechanical properties were achieved for the light-cured SBMP group, showing that the bonding strength as well as the mechanical properties were influenced by the interaction of materials. For mechanical properties analyzed, the light-curing of the adhesive systems didn’t present a statistically significant diference in the comparison between groups. In general, the application of adhesive systems on the silanized ceramic surface showed needless. Among the adhesives studied, SBU was the only system that showed effectiveness with or without previous light activation. For the other adhesive systems, SBMP and SB2, the previous light activation was necessary to optimize the bonding strength of the adhesive interface.
153

"Análise 'in vitro'da rugosidade superficial apresentada pelas porcelanas omega 900 e vitadur alpha após a utilização de três diferentes sistemas de polimento" / Omega 900 e vitadur alpha ceramics using three different polishing systems

Jesuina Lamartine Nogueira Araujo 25 June 2003 (has links)
RESUMO A qualidade da superfície de trabalhos cerâmicos que requer ajuste durante a sua adaptação ao remanescente dentário desperta a atenção durante os procedimentos odontológicos restauradores estéticos. Observa-se a necessidade freqüente de realizar desgastes superficiais nas restaurações cerâmicas, sendo que a preservação de uma superfície lisa é importante para as propriedades destes materiais, bem como para o seu comportamento clínico. Este trabalho propõe-se a avaliar a técnica com maior capacidade de polimento da superfície cerâmica asperizada, através da medição com ponta apalpadora de um rugosímetro, e utilizando o MEV para observações visuais com relação às técnicas empregadas. Para tal 80 corpos-de-prova foram confeccionados utilizando-se as porcelanas Omega 900 e Vitadur Alpha, constituindo quatro grupos experimentais: A – glaze (controle); B – polimento com borrachas abrasivas da DFL mais pasta para polimento da KOTA; C – polimento com borrachas abrasivas mais rodas de feltro mais pasta para polimento Porcelize (Cosmedent); D – polimento com borrachas abrasivas mais pasta porcelize mais discos Flexibuff mais pasta diamantada para brilho Enamelize (Cosmedent). Os dados receberam tratamento estatístico por meio da Análise de variância (ANOVA) e teste de Tukey, o qual indicou haver diferença estatisticamente significante entre os tipos de polimento para os quais as porcelanas foram submetidas, e na interação porcelana / polimento. Os resultados sugerem que todos os tratamentos polidores diminuem a rugosidade superficial das porcelanas em relação ao grupo controle e que dependendo da porcelana utilizada para cada técnica pode-se ter uma variação na rugosidade superficial. Quanto à observação pelo microscópio eletrônico de varredura houve uma correlação parcial entre este e os resultados obtidos pelo rugosímetro, pois aqui a porcelana Omega 900 mostrou-se mais polida no grupo controle, enquanto que na análise pelo rugosímetro apontou para a técnica polidora do Grupo D como sendo aquela que produziu uma superfície mais lisa para esta porcelana. Por outro lado, mostrou que o melhor polimento alcançado pela porcelana Vitadur Alpha foi através do polimento do Grupo C, o que está de acordo com os resultados obtidos pelo rugosímetro. / SUMMARY Aesthetic dentistry uses materials that can copy some lost caractheristics of the natural dentition, as color, mechanical resistance and smoothness.The better material for this are the ceramics. On the other hand, it is commum to have to grind them with diamond instruments for adjustment wich removes the glazed surfaces. This procedure can cause abrasion of the opposite teeth, plaque retention, injury of surrounding tissues and low aesthetics qualities. This study evaluated the roughness average in two dental ceramics, Omega 900 e Vitadur Alpha, that were grinding with diamond instruments after the glaze technique, and received three different polishing systems. The control group remained glazed until the end of the research. The groups were: Group A – control; Group B – grinding by fine and ultrafine points + polishing with DFL rubber points + KOTA diamond paste; Group C –grinding by fine and ultrafine points + polishing with rubber points + felt discs + Porcelize diamond paste (Cosmedent); Group D - grinding by fine and ultrafine points + polishing with rubber points + Porcelize + Flexibuff discs + Enamelize polishing paste (Cosmedent). To measure the roughness average in the samples it was used a profilometer Surftest SV-600 with the software Surfpack and the images were observed in the scanning electron microscopy (SEM) to comparation. The results received estatistical analysis using ANOVA and Tukey test (p˜0.05), and a significant tatistical difference was observed between the polishing systems , and in the porcelain/polishing interaction, which showed that all the polishing systems decreased the surface roughness of the porcelains after been grinding with diamond instruments, which was a better result than the control group. In the SEM analysis it was clear the presence of a partial relationship between the profilometer and that one, because here the Omega porcelain showed a more smoothness surface with the glazed treatment compaired with the others, differently from the profilometer analysis
154

Influência da atmosfera de sinterização sobre as propriedades elétricas de porcelanas aluminosas contendo diferentes concentrações de Fe2O3

Piva, Diógenes Honorato January 2014 (has links)
Este trabalho investigou a influência da atmosfera de sinterização sobre as propriedades elétricas de porcelanas aluminosas contendo diferentes concentrações de Fe2O3, sinterizadas em condições oxidantes e redutoras. A influência de tais variáveis sob a microestrutura, fases formadas e as propriedades elétricas foram investigadas com o auxílio de técnicas como difração de raios x, microscopia eletrônica de varredura e por espectroscopia de impedância. Os corpos cerâmicos foram formulados a partir de uma formulação obtida da literatura, considerada aplicável para porcelanas aluminosas de alto desempenho: 30 %p de feldspato, 30 %p de caulim e 40 %p de alumina. As formulações contendo diferentes concentrações de Fe2O3 foram divididas em dois grupos. Um primeiro queimado em ar atmosférico para criar a condição oxidante e um segundo queimado em solução gasosa CO/CO2 para criar uma condição redutora. Para as condições redutoras utilizou-se uma técnica conhecida como “cama de grafite”. As temperaturas de queima praticadas foram 1200, 1250 e 1300 °C. A análise dos corpos cerâmicos após queima indicou que todas as amostras apresentaram mullita e coríndon como fases majoritárias e pequenas frações de quartzo. Hematita e ferro metálico foram observados para as amostras contendo elevada concentração de Fe2O3. Para as condições oxidantes, a adição de Fe2O3 provocou uma diminuição na resistividade das amostras. A maior resistividade elétrica apresentada pela amostra contendo 3 %p de Fe2O3 foi atribuída à elevada presença de mullita. A presença de hematita para as amostras contendo acima de 3%p de Fe2O3 foi considerada como responsável pela diminuição na resistividade elétrica. A adição de Fe2O3 resultou em um aumento na resistividade das amostras sinterizadas em atmosfera oxidante. Esse aumento foi atribuída à elevada quantidade de fase vítrea de baixa condutividade e ao elevado número de poros para formulações contendo > 3%p de Fe2O3. Os resultados permitiram concluir que embora a presença de 3 %p de Fe2O3 seja vista como a concentração máxima aceitável, maiores teores de Fe2O3 podem ser utilizados para a produção de isoladores elétricos de porcelana. / This study investigates the influence of sintering atmosphere on the electrical properties of aluminous porcelains containing different concentrations of Fe2O3, sintered in oxidizing and reducing conditions. The influence of these variables on the microstructure, phase formation and electrical properties were investigated with the aid of techniques such as X-ray diffraction, scanning electron microscopy and impedance spectroscopy. The ceramic bodies were made from a formulation obtained from literature, aluminous porcelains considered applicable to High Performance: feldspar 30 wt%, 30 wt% kaolin and 40 wt% alumina. Formulations containing different concentrations of Fe2O3 were divided into two groups. A first burned in the atmospheric air to create the oxidizing condition and a second solution burned gas CO/CO2 to create a reducing condition. For the reducing conditions employed a technique known as "bed graphite." The firing temperatures were 1200, 1250 and 1300 ° C. The analysis of the ceramic bodies after sintering indicated that all samples showed corundum and mullite as major phases and small fractions of quartz. Hematite and metallic iron were observed for samples containing high concentration of Fe2O3. For oxidizing conditions, the addition of Fe2O3 caused a decrease in the resistivity of the samples. The higher electrical resistivity presented by the sample containing 3 wt% Fe2O3 was attributed to the high presence of mullite. The presence of hematite for samples containing up to 3 wt% Fe2O3 was considered responsible for the decrease in electrical resistivity. The addition of Fe2O3 resulted in an improvement in resistivity of the sample sintered in oxidizing atmosphere. This improvement is attributed to the high amount of glassy phase of low conductivity and high number of pores for formulations containing> 3 wt% Fe2O3. The results showed that although the presence of 3 wt% Fe2O3 is seen as the maximum acceptable concentration, higher concentrations of Fe2O3 can be used for the production of electrical porcelain insulators.
155

Adaptação marginal e resistencia a fratura de Inlays confeccionados em ceramica e compositos laboratoriais

Soares, Carlos José 12 December 2000 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T18:58:28Z (GMT). No. of bitstreams: 1 Soares_CarlosJose_M.pdf: 18449799 bytes, checksum: 7ca114de2d92eff546a3f14d3186d306 (MD5) Previous issue date: 2000 / Resumo: A proposta deste estudo foi avaliar a adaptação marginal e a resistência à fratura de "inlays" confeccionados em quatro sistemas restauradores indiretos, porcelana feldspática Duceram LFC (Degussa) e três resinas laboratoriais, Solidex (Shofu), Artg1ass Heraeus Kulzer) e Targis (Ivoclar). Foram selecionados 60 molares inferiores, com dimensões semelhantes, que foram incluídos em cilindros de resina com reprodução do ligamento periodontal. Os dentes receberam preparos MOD com 6 'GRAUS¿ de expulsividade, realizados em aparelho padronizador. Em seguida, foram moldados com silicona por adição e as restaurações confeccionadas seguindo as orientações dos fabricantes. A avaliação da adaptação marginal foi feita em sistema computadorizado de coleta de imagem associado a um aparelho digital de medição. Com aumento de 40x, determinaram-se os pontos de medição, sendo 4 pontos para cada região, eclusal, proximal e cervical e, com aumento de 250X, determinou-se o valor da discrepância marginal, através de um sistema de coordenadas digitais. As restaurações foram fixadas empregando a associação do sistema adesivo Single Bond e o cimento resinoso Rely X (3M) e armazenadas em 100% de umidade a 37° C por 24 horas. As amostras foram então submetidas a um carregamento axial de compressão com velocidade de 0,5 mm/minuto até a completa fratura da restauração. Os dentes fraturados foram analisados, classificando-se o padrão de fratura em cinco níveis: I -fratura isolada da restauração; II - fratura da restauração com pequena porção do dente; III -fratura da restauração com menos da Y2 do dente, sem envolvimento radicular; IV - fratura da restauração com mais da Y2 do dente, sem envolvimento radicular.; V -fratura com envolvimento radicular. A interface de fratura foi analisada por microscopia eletrônica de varredura. Os valores da adaptação marginal foram analisados estatisticamente aplicando a análise de variância segundo o esquema de parcelas subdivididas, sendo os materiais restauradores as parcelas e as regiões, as subparcelas. Verificaram-se diferenças estatisticamente significantes entre as regiões (p=0.0001), independente do tratamento estudado (p= 0.60555) e também entre os materiais restauradores (p= 0.0001). A discrepância marginal encontrada na região oclusal foi estatisticamente inferior à encontrada na região proximal, e esta menor que na região cervical. Entre os materiais restauradores, a adaptação marginal da cerâmica Duceram LFC foi estatisticamente inferior à encontrada para os materiais Solidex, Artglass e Targis em todas as regiões analisadas, não havendo diferenças entre estes. Os valores de resistência à fratura foram submetidos à análise de variância, demonstrando a ocorrência de diferenças estatisticamente significantes entre os materiais restauradores (p= 0,001). O teste de Tukey ('alfa¿= 0,05) foi aplicado, verificando que os dentes restaurados com Duceram LFC (205,44 '+ ou ¿' 39,5IKgf), apresentaram resistência média estatisticamente inferior aos grupos que receberam "inlays" confeccionados com os compósitos Solidex (293,16 '+ ou ¿' 45,86Kgf), Artglass (299,87 '+ ou ¿' 41,08Kgf) e Targis (304,23 '+ ou ¿' 52,52Kgf), não havendo diferenças entre os três compósitos laboratoriais. O padrão de fratura das amostras restauradas com cerâmica foi predominantemente do tipo I e II, por outro lado, as amostras restauradas com compósitos laboratoriais apresentaram padrões de fraturas predominantemente do tipo III, IV e V / Abstract: The aim of this study was to evaluate the marginal adaptation and the fracture strenght of four different inlay indirect restorative systems: feldspathic Duceram LFC (Degussa) and three laboratory resins, Solidex (Shofu), Artglass (Heraeus Kulzer) and Targis (Ivoclar). Sixty inferior molar tetth with similar dimensions were selected and included in resin cylinders, reproducing the periodontal ligaments. Six degree expulsive MOD inlay preparations were realized in a standard cavity preparation equipment. Afterwards, they were molded with polyvinyl siloxane impression and the restorations were prepared following the manufacturer¿s instructions. The marginal adaptation evaluation was realized with an image collector computer system associated with a digital gauging appliance. Four gauging points were established, with a 405 magnification, on the occlusal, proximal and cervical regions. The marginal discrepancy was recorded with a 230X magnification, by means of a digital coordinate system. The inlays were luted with composite resin Relay X (3M), and adhesive system Single Bond (3M) and restored at 37 'DEGREE¿C and 100% humidity for 24 hours. Then, the samples were submitted to an axial compression load on a 0,5mm/minute speed until the complete fracture of the restoration. The fractured teeth were analyzed, and the fracture patterns were established in five levels: I ¿ isolated fracture of the restoration; II ¿ fracture of the restoration with a small part of the tooth; III ¿ fracture of the restoration with less than half of the tooth, without radicular involvement; IV ¿ fracture of more than half of the tooth, without radicular involvement; V ¿ fracture with radicular involvement. The fracture intrface was analyzed with a scanning electron microscope. The marginal adaptation values were statistically analyzed with the subdivided parceks analysis of variance, in which the restorative materials were the parcels, and the regions, the sub-parcels. Statistically significant differences were seen among regions (p=0.0001), not depending on the treatment studied (p=0.60555), and among the restorative materiais (p=0.0001).The marginal discrepancy recorded on the occlusal region was statistically inferior to that recorded on the proximal region, and the latter, smaller than that on the cervical region. Among the restorative materiais, the marginal adaptation of Duceram LFC was statistically inferior to that found for the materiais Solidex, Artglass and Targis, which showed no statistical differences among them. The ftacture strength values were submitted to the ANOVA, which showed statistically significant differences among the restorative materiais (p = 0.001). Tukey test (cx=0.05)was applied, asserting that the teeth restored with Duceram LFC (205,44:t 39,5IKgf) showed statistically inferior values than the other groups which were restored with the resin composites Solidex (293,16:t 45,86 Kgf), Artglass (299,87 :t 41,08Kgf) and Targis (304,23 :t 52,52Kgt). The resin composites revealed no statistically significant differences for the ftacture resistance values. The fracture pattems for the samples restored with porcelain were predominantly type I and fi, whereas the ftacture patterns recorded for the samples restored with indirect composites were mostly type m, IV, V / Mestrado / Dentística / Mestre em Clínica Odontológica
156

Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricos

Antônio Francisco Grando 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
157

A avaliação da confiabilidade e modo de falha de coroas de sistemas cerâmicos em função do desenho da infraestrutura e da aplicação de carga em cristas marginais / Evaluation of reliability and failure modes of ceramic crown systems depending on framework design and marginal ridge load application

Vinícius Pavesi Fardin 29 May 2013 (has links)
As excelentes propriedades mecânicas da zircônia fazem com que ela seja o material cerâmico de eleição para as coroas e próteses fixas posteriores. Porém, os problemas relacionados à fratura ainda persistem. A falta de suporte das infraestruturas às cerâmicas de revestimento é indicada como uma possível causa. O presente estudo visou avaliar através de testes laboratoriais se as infraestruturas metálicas e cerâmicas com o desenho convencional ou modificado apresentam diferença estatisticamente significante quanto à redução de complicações mecânicas, como fraturas e trincas na cerâmica de revestimento ao receberem cargas axiais nas cristas marginais de coroas de um primeiro molar inferior, por meio das seguintes hipóteses nulas: 1) a resposta à fadiga nas cristas marginais não aumentará a presença de danos nas coroas; 2) o desenho da I.E. não modificará a presença de danos nas coroas, independente do material utilizado. Quarenta coroas unitárias foram confeccionadas sobre preparos padronizados e divididos em 4 grupos: grupo I (infraestrutura convencional de Cobalto-Cromo); grupo II (infraestrutura modificada de Cobalto-Cromo); grupo III (infraestrutura convencional de Zircônia - IPS Emax ZirCAD); grupo IV (infraestrutura modificada de Zircônia - IPS Emax ZirCAD). Estas coroas foram submetidas ao teste de resistência à fadiga por meio da ciclagem dinâmica em água (106 ciclos ou até a fratura com carga variando de 30-300 N). Aplicou-se a carga inicial com o endentador cerâmico de dissilicato de lítio (IPS Emax Press) na crista marginal mesial, e após o término do ciclo, na distal, alternativamente. A ciclagem foi interrompida em intervalos de 125 mil ciclos a procura de danos com auxílio de estereomicroscopia. Ao final, as coroas fraturadas foram submetidas à microscopia eletrônica de varredura e as não fraturadas foram incluídas em resina epóxi e polidas sequencialmente para a análise dos danos. Cada corpo de prova recebeu escores de acordo com o tipo de falha apresentado. Utilizou-se o teste Kruskal-Wallis para verificar diferença estatística entre os grupos e o teste de Dunn para comparações múltiplas entre os grupos. Os resultados mostraram que há diferença estatisticamente significante entre os grupos, entretanto não houve diferença entre os grupos do mesmo sistema cerâmico. Concluiu-se que a hipótese 1 foi aceita e a 2 rejeitada. / The excellent mechanical properties of zirconia make it to be the material of choice for ceramic crowns and posterior fixed prostheses. However, problems still exist related to the chippings. The lack of framework support to ceramic veneer is indicated as a possible cause. This study aimed to evaluate through laboratory tests if metallic and ceramic framework with conventional or modified design show statistical difference in reducing mechanical complications, such as chipping or fracture of the ceramic veneer on receiving axial loads in marginal ridges of the first molar inferior crowns through the following null hypotheses: 1) the response to fatigue in marginal ridges will not increase the presence of damage to the crowns; 2) framework`s design will not modify the presence of damage to the crowns, regardless of the material used. Forty crowns were manufactured on standardized preparations and divided into four groups: group I (conventional framework Cobalt-Chromium), group II (modified framework Cobalt-chromium), group III (conventional framework Zirconia - ZirCAD IPS Emax) and group IV (modified framework Zirconia - IPS Emax ZirCAD). These crowns were subjected to cyclic loading in a fatigue machine and submerged in water (1.000.000 cycles or until the fracture - load range at 30-300 N). The initial load was applied on the mesial marginal ridge with indenter ceramic Lithium disilicate (IPS Emax Press), and after the end of the cycle, the distal alternatively. The cycling was interrupted at a prescribed number of loading cycles (125.000) and crowns were inspected for damage accumulation under a stereomicroscope. In the end, fractured crowns were submitted to scanning electron microscopy and crowns without fractures were embedded in epoxy resin and sequentially polished for the analysis of the damage. Each sample received scores according to the type of failure presented. Statistical analysis was carried out with Kruskal-Wallis test and multiple conparisons between groups were carried out with Dunn wed significant differences between groups, however there was no difference between the groups of the same ceramic systems. It was concluded that the first hypothesis was accepted and the second hypothesis was rejected.
158

\"Estudo espectrofotométrico comparativo da estabilidade de cor de três porcelanas dentais após consecutivas queimas\" / Comparative spectrophotometric study of the color stability of three dental porcelains after repeated firings

Marcelo Weber 25 September 2006 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor de três marcas comerciais de porcelanas aluminizadas durante seu processo de queima. Para o experimento foram confeccionados 30 corpos de prova em forma de disco com 2mm de espessura e 10mm de circunferência, sendo 10 da marca ALLCeram, 10 da marca Noritake Cerabien CZR e 10 da marca Vita VM7. As amostras foram queimadas 10 vezes. As leituras de cor foram feitas em espectrofotômetro de reflexão nos seguintes intervalos: após a 1ª queima, após a 3ª queima, após a 5ª queima e após a 10ª queima. As curvas de reflexão foram convertidas em valores LAB e a diferença de cor foi medida através do método CIELAB (FE). Os resultados obtidos demonstraram que existe variação de cor e que esta variação depende do número de queimas realizadas e da marca comercial utilizada. / The purpose of this investigation was to quantify in CIE FE units the differences in color produced by multiple firing of three allceramic systems. For this study 30 samples were fabricated of 3 brands: AllCeram, Noritake Cerabien CZR and Vita VM7. A spectrophotometer was used for reflectance measurement of color after 1 firing, 3 firings, 5 firings and 10 firings. The results were converted in CIELAB units. Color differences, FE, were calculated in the CIE color space. Color differences as a result of multiple firings depended on the number of firings and the brand tested.
159

Tratamento de superfície de porcelanas dentárias pela irradiação com laser de CO2 / Surface treatment of dental porcelains with CO2 laser

Ricardo Sgura 04 July 2013 (has links)
Este estudo teve como objetivo testar o laser de CO2 como um agente de tratamento de superfície de porcelanas dentárias. Material e Métodos: O estudo foi dividido em duas etapas: na primeira etapa, discos de porcelana (3,5 mm diam. x 2,0 mm espess.) das marcas VM7, VM9 e VM13 (VITA) foram sinterizados e tiveram uma de suas faces asperizadas por uma ponta diamantada 2134F para acabamento. Os espécimes foram então divididos em grupos de acordo com os seguintes tratamentos: nenhum (C), auto-glaze em forno (G) e irradiação com laser (L) de CO2 (Coherent, = 10,6 m, 35 W) de forma contínua com 40, 45 ou 50 W/cm2 nos tempos de 3, 4 ou 5 minutos (n=7). Nesta primeira etapa, as caracterizações das amostras constaram de: difratometria por raios-X, diferença de cor (Easyshade VITA), rugosidade superficial (Surftest 301, Mitutoyo) e análise visual por meio de esteromicroscopia e MEV. Um espécime de VM9 de cada grupo foi polido e levado a um exame por microscopia de força atômica (MFA). A segunda etapa consistiu na sinterização de discos das três porcelanas nas mesmas dimensões da etapa anterior, porém submetidos a um polimento de uma das superfícies com soluções diamantadas de granulação decrescente até 1 m. Os grupos testados foram os mesmos da primeira etapa, com exceção dos grupos irradiados com 40W/cm2. As caracterizações que se seguiram foram (n=10): microdureza Vickers, tenacidade à fratura, porosidade superficial, razão de contraste (RC) e capacidade de mascaramento (CM). Resultados: A rugosidade de espécimes asperizados foi diminuída pela aplicação do laser nas irradiâncias de 45 e 50 W/cm2, similar ao auto-glaze em forno, sem alteração de cor perceptível para a quase totalidade dos grupos irradiados. Houve um aumento do conteúdo cristalino das porcelanas VM9 e VM13 após a irradiação com o laser. As micrografias (MEV) demonstraram padrão de superfície homogêneo para os espécimes dos grupos irradiados a 50 W/cm2 e G. Os resultados da segunda etapa apontaram para alterações na microdureza e tenacidade à fratura na dependência da marca comercial e das irradiâncias estudadas. Quanto à porosidade, as porcelanas VM7 e VM13 apresentaram um aumento na fração volumétrica de poros, enquanto a porcelana VM9 irradiada apresentou-se semelhante a G. As médias de RC e CM indicaram um aumento na opacidade das porcelanas VM7 e VM13 irradiadas com o laser. Conclusão: Em condições específicas, o laser de CO2 é capaz de produzir uma lisura de superfície semelhante ao auto-glaze, com pequenas alterações nos aspectos ópticos e mecânicos. As diferentes marcas comerciais de porcelana apresentaram comportamentos distintos em relação aos tratamentos aplicados. / Glazing porcelain is an important procedure in dentistry that leads to surface smoothness, to less plaque accumulation and to brightness, especially after a chair side adjustment. Despite a good absorption of CO2 laser wavelength by dental porcelain it has not yet been tested as an alternative to oven glaze. Aim: This study tested CO2 laser as a heat source in surface treatment of dental porcelains. Material and Methods: This study was divided in two stages: at the first stage porcelain discs (VM7, VM9, VM13 VITA; 3.5 diam. x 2.0 mm thickness) were sintered, machined and had one of their sides grounded by a diamond bur (2134F KG Sorensen) simulating a chair side adjustment in clinical office. Specimens were then divided into groups according to treatment: no treatment (C); auto-glazed in conventional furnace (G) and submitted to CO2 continuous laser irradiation (Coherent, = 10.6 m; output power = 35 W, 0.5 cm laser beam) in 40, 45 or 50 W/cm2 for 3, 4 or 5 minutes (n=7). Specimens were supported by a ceramic refractory. At this first stage, the characterization consisted of X-ray diffraction (RU-200B, Rigaku), color difference (E) (Easyshade VITA), roughness (Surftest 301, Mitutoyo) and analysis of images achieved by stereomicroscopy (SZ61, Olympus) and SEM (Stereoscan 440, LEO). A VM9 specimen of each group had one of their side polished and was submitted to atomic force microscopy (AFM) Nanoscope IIIA (Veeco). In the second stage discs with the same dimension described above were sintered and polished with diamond solutions (Ecomet 3; 1 m). The same groups were tested except 40W/cm2 irradiance. Specimens were submitted to the following characterizations (n=10): Vickers microhardness test, fracture toughness by indentation fracture (HMV, Shimadzu), surface porosity (HMV, Image J software), contrast ratio (CR) and masking ability (MA) (CM-3770d, Konica Minolta). Results from both stages were submitted to one-way-ANOVA or Kruskall-Wallis test. A post-hoc Tukey test was applied when necessary ( = 0.05). Results: Ground specimens showed a reduction in roughness after laser irradiation (45 and 50 W/cm2), comparable to oven-glazed specimens with almost no color change. SEM images presented similarity between a irradiated group (50W/cm2) and G. AFM test revealed the formation of long rounded peaks and long valleys after laser exposition. Second stage results pointed to changes in microhardness and fracture toughness of irradiated specimens depending on the porcelain and irradiance tested. Regarding porosity, after laser exposition, porcelain VM7 and VM13 presented an increase in pores (area fraction) for the majority of groups while VM9 porcelain didnt show any increase in porosity after laser incidence. CR and MA means pointed to an increase in porcelain opacity to irradiated specimens of VM7 and VM13. Conclusion: Under specific conditions CO2 laser was able to produce a surface smoothness similar to auto-glaze, despite punctual changes in some optical and mechanical properties. The different brands presented distinct effects after laser heat treatment.
160

Avaliação in vitro da resistência ao cisilhamento de três agentes cimentantes em porcelana feldspática / Shear bond strength in vitro evaluation of three ciments in feldspathic porcelain

Ivonne Mariel Tavarez Vasquez 23 November 2009 (has links)
O presente estudo teve como objetivo comparar as resistências adesivas de três cimentos, entre dentina bovina e uma porcelana (Star Light Ceram) através de ensaio de cisalhamento em dois períodos de tempo. Foram utilizados incisivos bovinos incluídos numa matriz com resina epóxica. Cilíndros de porcelana (5 mm de altura e 6 mm de diâmetro) foram confeccionados. Foram confeccionados 10 corpos de prova para cada condição experimental. Os grupos foram divididos em: cimento resinoso RelyX ARC; cimento ionômero de vidro modificado por resina; cimento resinoso U100. Os dois primeiros materiais foram condicionados e receberam o seguinte tratamento: ácido fluorídrico por 2 min sobre a porcelana. Lavado e secado, foi aplicado uma camada fina de silano e logo aplicação do sistema de cimentação. A dentina bovina recebeu o seguinte tratamento: condicionamento com acido fosfórico a 35% por 20 s. e sistema adesivo Adper SingleBond 2. Os espécimes foram armazenados em água deionizada a 37° C por 24 horas ou 7 dias . Os espécimes foram submeidos a esforços de cisalhamento em uma máquina universal de ensaios. Os resultados foram submetidos à análise de variância a um critério (=0,05) e teste de Tukey. Houve diferença entre os cimentos estudados. O tratamento superficial da porcelana influenciou a resistência adesiva, porém não houve diferença significante entre os tempos de armazenamento. O cimento resinoso dual RelyX ARC com tratamento de superfície da porcelana apresentou maior resistência adesiva. / The present study had the aim to compare shear bond strengths of three cements used in bovine dentin and porcelain (Star Light Ceram) throught shear test in two periods. Bovine incisors were included in epoxic resin. Porcelain cylinders (5mm height and 6mm diameter) were prepared. 10 samples for each experimental condition were prepared. The groups were divided in: resin cement ARC; resin modified glass ionomer cement; self-adhesive cement U100. The first two materials were conditioned and received the following treatment: the porcelain received hidrofluoridric acid for 2min, rinsed and dried, with a thin silane layer being applied, before cementation; the dentin was conditioned with 35% phosphoric acid for 20s before the adhesive Adper SingleBond 2 application. Samples were stored in deionized watee at 37°C for 24h or 7 days. Samples were evaluated in shear in a universal testing machine. The results were analysed with one way analysis of variance (=0.05) and Tukeys test. There were differences between studied cements. The porcelain surface treatment influenced shear bond strength, however there were no significant differences between storage periods. The dual cured resin cement RelyX ARC with porcelain surface treatment showed higher shear bond strength.

Page generated in 0.0478 seconds