• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 103
  • 1
  • Tagged with
  • 104
  • 104
  • 104
  • 104
  • 104
  • 87
  • 64
  • 62
  • 61
  • 59
  • 54
  • 49
  • 39
  • 25
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea : estudo pelo método dos elementos finitos tridimensionais /

Antenucci, Rosse Mary Falcón. January 2011 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Pedro Yoshito Noritomi / Banca: Paulo Sérgio Perri de Carvalho / Banca: Fellippo Ramos Verri / Banca: Marcelo Ferraz Mesquita / Banca: Pedro Tortamano Neto / Resumo: Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below) / Doutor
42

Influência da carga oclusal parafuncional em próteses implantossuportadas, variando-se a proporção coroa/implante e o sistema de conexão protética : estudo pelo método dos elementos finitos tridimensionais /

Torcato, Leonardo Bueno. January 2013 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Ferraz Mesquita / Banca: Fellippo Ramos Verri / Resumo: A condição de carga tem sido considerada o fator mais importante para a manutenção em longo-prazo da osseointegração e sucesso do tratamento reabilitador, portanto, é essencial otimizar a distribuição da carga mastigatória no complexo implante-coroa-parafuso. A proposta do presente estudo foi analisar, através do método dos elementos finitos tridimensionais, a influência do carregamento oclusal parafuncional, da proporção coroa/implante e da conexão protética (hexágono externo, hexágono interno e cone-morse) na distribuição das tensões em próteses unitárias implantossuportadas. Foram confeccionados cinco modelos tridimensionais com o auxílio de um scanner 3D MDX-20 e dos programas de modelagem gráfica: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks 2010 (SolidWorks Corp, Massachusetts, USA). Cada modelo foi composto por um bloco ósseo proveniente da região molar mandibular, por um implante dentário (Conexão Sistema de Prótese Ltda, São Paulo, Brasil) e por coroa metalocerâmica com diferentes alturas: 10, 12.5 e 15 mm. Os modelos tridimensionais foram exportados para o programa de elementos finitos FEMAP 10.1 (Noran Engineering, Inc., EUA), para estabelecimento das condições de contorno e geração da malha de elementos finitos. Aplicou-se uma carga funcional (200 N axial e 100 N oblíqua), bem como uma carga parafuncional (1000 N axial e 500 N oblíqua). A carga axial foi dividida em 4 pontos, localizados nas vertentes internas das cúspides, enquanto que a carga oblíqua foi dividida em 2 pontos, os quais localizaram-se nas vertentes internas das cúspides linguais. Os resultados foram visualizados por meio dos mapas de Tensão de von Mises e mapas de Tensão Máxima Principal. O carregamento parafuncional e o aumento da proporção coroa/implante induziram um aumento da área de distribuição e da magnitude das tensões no ... / Abstract: The load condition has been considered the most important factor for the long-term osseointegration maintenance and for the rehabilitation treatment success, then, it is essential to optimize the masticatory loading distribution on the implant-crown-screw complex. The purpose of this study was to analyze, through the 3D finite element method, the influence of parafunctional occlusal loading, the crown/implant ratio and the prosthetic connection (external hexagon, internal hexagon and morsetaper) on stress distribution in implant-supported single prostheses. Five 3D models were created with the aid of a 3D scanner MDX-20 and the graphical modeling softwares: Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks 2010 (SolidWorks Corp., Massachusetts , USA). Each model was composed of a bone block from the mandibular molar region, a dental implant (Conexão Sistema de Prótese Ltda, São Paulo, Brazil) and a metal-ceramic crown with different heights: 10, 12.5 and 15 mm. The 3D models were exported to the finite element software FEMAP 10.1 (Noran Engineering, Inc., USA) to have the boundary conditions established and the finite element meshes generated. A functional load (200 N axial and 100 N oblique) and a parafunctional load (1000 N axial and 500 N oblique) were applied on the occlusal surface of the crowns. The axial load was divided in four points located in the internal slope of the cusps, while the oblique load was divided into two spots, which were located in the internal slopes of the lingual cusps. The results were visualized through von Mises Stress and Maximum Principal Stress maps. The parafunctional load and the increased crown/implant ratio caused an increase in the distribution area and of the magnitude of the stresses in the implant (hexagon region, platform and first thread) and screw (neck). The conical internal connection ... / Mestre
43

Resistência à fratura de infraestruturas de próteses totais implantossuportadas em função de diferentes desenhos de cantilever e espessura do conector distal: estudo in vitro / Fracture resistance of infrastructure implant-supported dentures due to different design of cantilever and the thickness of the distal connector : in vitro study

Oliveira, Brunamélia de [UNESP] 25 July 2016 (has links)
Submitted by BRUNAMÉLIA DE OLIVEIRA null (brunamoliveira@hotmail.com) on 2016-09-16T11:59:43Z No. of bitstreams: 1 TESE DOUTORADO_23-agost-2016- wirley.doc: 39192064 bytes, checksum: 979dfe3777702d653e46da90ffda2ead (MD5) / Rejected by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Por favor, corrija o formato do arquivo e realize uma nova submissão. Agradecemos a compreensão. on 2016-09-21T13:09:53Z (GMT) / Submitted by BRUNAMÉLIA DE OLIVEIRA null (brunamoliveira@hotmail.com) on 2016-09-21T13:51:25Z No. of bitstreams: 1 TESE DOUTORADO Brunamélia de Oliveira-PDF.pdf: 1338467 bytes, checksum: 256bd9b6a59b22460bfa4b2d78f3caa4 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-09-21T20:35:33Z (GMT) No. of bitstreams: 1 oliveira_b_dr_araca.pdf: 1338467 bytes, checksum: 256bd9b6a59b22460bfa4b2d78f3caa4 (MD5) / Made available in DSpace on 2016-09-21T20:35:33Z (GMT). No. of bitstreams: 1 oliveira_b_dr_araca.pdf: 1338467 bytes, checksum: 256bd9b6a59b22460bfa4b2d78f3caa4 (MD5) Previous issue date: 2016-07-25 / O objetivo do presente trabalho foi avaliar, por meio de teste de compressão, a resistência à fratura de infraestruturas metálicas de próteses totais implantossuportadas do tipo protocolo de Branemark em função de diferentes designs (comprimentos e altura) do cantilever, bem como espessura do conector distal. Foram confeccionadas 39 infraestruturas (barras) em liga de CoCr agrupadas de acordo com o comprimento do cantilever (cc) (12mm, 19mm e 26mm), altura do cantilever (hc) (3,2 mm, 4mm) e espessura do conector distal (ec) (0,4mm, 1,5mm e 2mm). Os grupo foram divididos em Controle (cc 12mm; hc 4mm; ec 1,5),Grupo 1 (cc 12mm; hc 4mm; ec 0,4mm), Grupo 2(cc 12mm; hc 3,2mm; ec 0,4mm), Grupo 3 (cc 12mm; hc 3,2mm; ec 1,5mm), Grupo 4 (cc 19mm; hc 4mm; ec 1,5mm), Grupo 5 (cc 19mm; hc 4mm; ec 0,4mm), Grupo 6 (cc 19mm; hc 3,2mm; ec 1,5mm), Grupo 7 (cc 19mm; hc 3,2mm; ec 0,4mm), Grupo 8 (cc 26mm; hc 4mm; ec 1,5mm), Grupo 9 (cc 26mm; hc 4mm; ec 0,4mm), Grupo 10 (cc 26mm; hc 3,2mm; ec 1,5mm) e Grupo 11 (cc 26mm; hc 3,2mm; ec 0,4mm). Todos os espécimes foram submetidos a ensaio de compressão em uma maquina de ensaio universal com célula de carga de 5000N e velocidade constante de 0,5mm/min. Os dados obtidos foram submetidos a analise estatística ANOVA a três critérios, seguido pelo teste de Tukey, com nível se significância de 5% (p<0,05). Foi observada uma diferença significante na diminuição de resistência a compressão com o aumento do comprimento do cantilever, um aumento significante de resistência nos grupos com altura de cantileveres maiores. Foi concluído que quanto menor o comprimento e maior a altura do cantielver, maior será a resistência. Já a espessura do conector influenciou a resistência, porém sem uniformidade. / The aim of this study was to evaluate, through compression test, the fracture strength of metal infrastructure dentures implant of the Branemark protocol type for different designs (length and height) of the cantilever and thickness of the connector distal. 39 were prepared infrastructure (bar) pooled CoCr alloy according to the length of the cantilever (cc) (12mm, 19mm and 26mm), the cantilever height (hc) (3.2mm, 4mm) thick and the distal connector ( c) (0.4mm, 1.5mm and 2mm). The group were divided into control (cc 12mm; hc 4mm and c 1.5), Group 1 (cc 12mm; hc 4mm, 0.4mm c), Group 2 (cc 12 mm; hc 3.2mm, 0.4mm and c) Group 3 (cc 12 mm; hc 3.2mm, 1.5mm c), Group 4 (cc 19mm; hc 4mm, 1.5mm c), Group 5 (cc 19mm; hc 4mm, 0.4mm c), Group 6 (cc 19mm; hc 3.2mm, 1.5mm c), Group 7 (cc 19mm; hc 3.2mm, 0.4mm c), Group 8 (cc 26mm; hc 4mm, 1.5mm c), Group 9 ( cc 26mm; hc 4mm, 0.4mm c) Group 10 (cc 26mm; hc 3.2mm, 1.5mm c) and Group 11 (cc 26mm; hc 3.2mm, 0.4mm and c). All specimens were subjected to compression test in a universal testing machine with 5000N load cell and constant speed of 0.5 mm / min. Data were analyzed by ANOVA statistical analysis three criteria, followed by Tukey test, with significance level was 5% (p <0.05). a significant difference in the decrease of resistance to compression with increasing length of the cantilever, a significant increase in resistance groups with height greater cantilevers was observed. It was concluded smaller length and greater height of cantielver, the greater the resistance. Already the connector thickness influenced the resistance, but without uniformity.
44

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four / In vitro analysis of the accuracy of splinting impression techniques using all-on-four system

Pimentel, Gustavo Henrique Diniz [UNESP] 15 October 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000874738.pdf: 3429941 bytes, checksum: f0746f3294aca82e94682f551d6b7ae5 (MD5) / O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
45

Efeito de condições artificiais de envelhecimento sobre pilares de zircônia tetragonal estabilizada por ítria (Y-TZP). Análise fractográfica dos modos de falha

Basílio, Mariana de Almeida [UNESP] 03 August 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-03. Added 1 bitstream(s) on 2016-12-09T13:55:27Z : No. of bitstreams: 1 000867882.pdf: 3085255 bytes, checksum: 012ee4676be6e42295f4d0987012b15a (MD5) / Pilares cerâmicos são geralmente fabricados em zircônia tetragonal estabilizada por ítria (Y-TZP). Os objetivos desse estudo foram avaliar os efeitos de condições artificiais de envelhecimento sobre a carga de fratura, estabilidade de fase e microtopografia superficial de um pilar de Y-TZP e estabelecer possíveis razões de falha utilizando análise fractográfica. Trinta e dois pilares pré-fabricados de Y-TZP foram aparafusados a implantes tipo hexágono externo e divididos em 4 grupos (n=8): 1 - controle, 2 - ciclagem mecânica em água (1 x 106 ciclos), 2 - autoclavagem (134ºC; 5 horas; 2 bar), 3 - termociclagem (104 ciclos; 5ºC/55ºC). Ensaio de resistência à fratura foi realizado com velocidade de carga de 0,5 mm/min. Transformação de fase tetragonal-monoclínica (t-m) foi observada e quantificada por análise de difração de raios X do pó (XRPD). Microestrutura superficial foi analisada por microscopia eletrônica de varredura (MEV) de alta resolução. Análise fractográfica foi conduzida utilizando estereomicroscópio e MEV. ANOVA e teste Tukey compararam os dados de resistência à fratura (α=0,05). Todas as condições de envelhecimento reduziram a resistência à fratura significativamente (ρ<0,001) e levaram à transformação de fase t-m. Ciclagem mecânica reduziu a resistência mais do que autoclavagem (ρ=0,034). MEV detectou falhas e microtrincas superficiais. Achados fractográficos mostraram que as falhas iniciaram nas regiões em contato com os ângulos da cabeça do parafuso. Condições hidrotérmicas e mecânica associadas ao seu processo de microfratura foram as prováveis causas de degradação da resistência. Esse estudo observou um padrão de fratura na região da conexão e que o design do parafuso contribuiu para ocorrência das fraturas. / Most ceramic abutments are fabricated from yttria-stabilized tetragonal zirconia (Y-TZP). The objectives of this work were to assess the effects of artificial ageing conditions on the fracture load, phase stability and surface microstructure of a Y-TZP abutment, and to establish possible reasons for failure by fractographic analysis. Thirty two prefabricated Y-TZP abutments were screwed and torqued down to external hex implants and divided into 4 groups (n=8): 1 - control, 2 - mechanical cycling in water (1 x 106 cycles), 3 - autoclaving (134ºC; 5 hours; 2 bar), 4 - thermal cycling (104 cycles; 5º/55ºC). A single-load-to-fracture test was performed at a crosshead speed of 0.5 mm/min to assess the assembly's fracture load. X-ray powder diffraction (XRPD) analysis was applied to observe and quantify the tetragonal-monoclinic (t-m) phase transformation. Representative specimens were examined with high-resolution scanning electron microscopy (SEM) to observe the abutments' surface microstructure. Fractographic analysis was conducted under stereo and SEM. The fracture load data were compared using ANOVA and Tukey test (α=.05). All the ageing conditions reduced the fracture load significantly (ρ<0.001) and led to t-m transformation. Mechanical cycling reduced the fracture load more than autoclaving (ρ=0.034). The SEM detected surface flaws and micro-cracks. Fractographic features showed that failure started at the abutment regions in contact with the retention screw edges. Hydrothermal and mechanical conditions associated with their micro-fracture process were the most likely causes for strength degradation. This study established a fracture pattern at the connecting area and that the abutment screw could affect the occurrence of fractures
46

Análise de tensão de diferentes materiais fresados por CAD/CAM em próteses sobre implantes / Tension analysis of different materials milled by CAD/CAM on implant prosthesis

Mascarenhas, Vinicius Ibiapina [UNESP] 23 March 2018 (has links)
Submitted by VINICIUS IBIAPINA MASCARENHAS (vinicius_ibiapina@hotmail.com) on 2018-05-08T13:56:42Z No. of bitstreams: 1 VINICIUS IBIAPINA MASCARENHAS - TESE DOUTORADO.pdf: 37143807 bytes, checksum: 5f3ad0aba115e339bae69a77b7f93858 (MD5) / Approved for entry into archive by Ceres Maria Carvalho Galvão de Freitas null (ceres@foar.unesp.br) on 2018-05-09T12:13:25Z (GMT) No. of bitstreams: 1 marcarenhas_vi_dr_arafo_int.pdf: 37143807 bytes, checksum: 5f3ad0aba115e339bae69a77b7f93858 (MD5) / Made available in DSpace on 2018-05-09T12:13:25Z (GMT). No. of bitstreams: 1 marcarenhas_vi_dr_arafo_int.pdf: 37143807 bytes, checksum: 5f3ad0aba115e339bae69a77b7f93858 (MD5) Previous issue date: 2018-03-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Buscando o melhor entendimento sobre as forças oclusais que influenciam diretamente na longevidade dos materiais fresados em CAD/CAM, tecidos e, consequentemente, tratamentos reabilitadores, este estudo pretende avaliar a distribuição de tensão mecânica em coroas implantossuportadas e na interface osso-implante, analisando de que maneira diferentes materiais de cobertura protética (dissilicato de lítio, resina composta e composto híbrido Enamic ) se comportam em situações clínicas simuladas com implantes curtos, utilizando a análise fotoelástica com observação e análise das franjas isocromáticas. Dois implantes hexágono externo de diâmetro 5 milímetros e comprimento de 5,5 e 13 milímetros foram incluídos cada um em um bloco de resina fotoelástica de dimensões 65 x 30 x 15 mm (largura, comprimento e profundidade), instalados coroas fresadas em CAD/CAM sendo uma de compósito, outra de cerâmica dissilicato de lítio e uma terceira de um composto cerâmico híbrido. Ao conjunto foi-se submetido uma força vertical de 10 N suficiente para gerar uma resposta mecânica na coroa. Foram colhidas imagens das franjas isocromáticas observadas em frente a um polaroscópio circular com o uso de uma câmera semi-profissional e os dados foram analisados em 5 pontos diferentes ao redor do implante de acordo com a intensidade de cor gerada pelas franjas isocromáticas. Após análise estatística não se observou diferença na dissipação de força na resina fotoelástica quando comparadas as diferentes coroas testadas, no entanto quando a comparação foi feita entre implante curto e longo, pode-se observar uma maior e estatisticamente significante intensidade de estresse mecânico nos implantes curtos principalmente na região cervical. Assim, pode-se concluir que implantes curtos sofrem com mais estresse mecânico que implantes de comprimento maior porém diferentes materiais de revestimento protético em coroas sobre implante não influenciam na dissipação de força na região periimplantar de acordo com a metodologia estudada. / In order to better understand the occlusal forces that directly influence the longevity of materials machined in CAD / CAM, tissues and, consequently, rehabilitation treatments, this study intends to evaluate the mechanical stress distribution in implant-supported crowns and the bone-implant interface, analyzing (Lithium disilicate, zirconium dioxide and Enamic hybrid compound) behave in simulated clinical situations with short implants using photoelastic analysis with observation and analysis of the isochromatic fringes. Two external hexagon implants with a diameter of 5 mm and a height of 5.5 and 13 mm were each included in a block of photoelastic resin of dimensions 65 x 30 x 15 mm (width, height and depth), installed crowns in CAD / CAM being one of composite, another of disilicate lithium ceramic and a third of a hybrid ceramic compound. A vertical force of 10 N was sufficient to generate a mechanical response on the resin. Images were taken from the isochromatic fringes observed in front of a circular polaroscope with the use of a semi-professional camera and the data were analyzed in 5 different points around the implant according to the color intensity generated by the isochromatic fringes. After statistical analysis, it was not observed a difference in force distribution on photoelastic resin when compared the different crowns tested, however when the comparison was made between short and long implant, a higher and statistically significant mechanical stress intensity could be observed in the short implants especially in the cervical region. Thus, it can be concluded that short implants suffer from more mechanical stress than large-length implants, but different materials of prosthetic coating on implant crowns do not influence the dissipation of force in the periimplant region according to the methodology studied.
47

Resistência à fratura de infraestruturas de próteses totais implantossuportadas em função de diferentes desenhos de cantilever e espessura do conector distal : estudo in vitro /

Oliveira, Brunamélia de. January 2016 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Humberto Gennari Filho / Banca: Juliana Aparecida Delben / Banca: Erica Alves Gomes / Resumo: O o bjetivo do presente trabalho foi avaliar, por meio de teste de compressão, a resistência à fratura de infraestruturas metálicas de próteses totais implantossuportadas do tipo protocolo de Branemark em função de diferentes designs ( comprimentos e altura) do cantilever, b e m como espessura do conector distal . Foram confeccionadas 39 infraestruturas ( barras ) em liga de CoCr agrupadas de acordo com o comprimento d o cantilever (cc) (12mm, 19mm e 26mm), altura do cantilever (hc) (3, 2 mm, 4mm) e espessura do conector distal (ec) (0,4mm, 1,5mm e 2mm). Os grupo foram divididos em Controle (cc 12mm; hc 4mm; ec 1,5),Grupo 1 (cc 12mm ; hc 4mm; ec 0,4mm), Grupo 2 (cc 12mm; hc 3,2mm; ec 0,4mm), Grupo 3 (cc 12mm; hc 3,2mm; ec 1,5mm), Grupo 4 (cc 19mm; hc 4mm; ec 1,5mm), Grupo 5 (cc 19mm; hc 4mm; ec 0,4mm), Grupo 6 (cc 19mm; hc 3,2mm; ec 1,5mm), Grupo 7 (cc 19mm; hc 3,2mm; ec 0,4mm), Grupo 8 (cc 26m m; hc 4mm; ec 1,5mm), Grupo 9 (cc 26mm; hc 4mm; ec 0,4mm), Grupo 1 0 (cc 26mm; hc 3,2mm; ec 1,5mm) e Grupo 1 1 (cc 26mm; hc 3,2mm; ec 0,4mm). Tod o s o s espécimes foram submetid o s a ensaio de compressão em uma maquina de ensaio universal com célula de carga de 5000N e velocidade constante de 0,5mm/min . Os dados obtidos foram submetidos a analise estatística ANOVA a três critérios, seguido pelo teste de Tukey, com nível se significância de 5% (p< 0,0 5 ). Foi observada uma diferença significante na diminuição de re sistência a compressão com o aumento do comprimento do cantilever, um aumento significante de resistência nos grupos com altura de cantileveres maiores . Foi concluído que quanto menor o comprimento e maior a altura do cantielver, maior será a resistência. Já a espessura do conector influenciou a resistência, porém sem uniformidade. / Abstract: The aim of this study was to evaluate, thr ough compression test, the fracture strength of metal infrastructure dentures implant of the Branemark protocol type for different designs (length and height) of the cantilever and thickness of the connector distal. 39 were prepared infrastructure (bar) po oled CoCr alloy according to the length of the cantilever (cc) (12mm, 19mm and 26mm), the cantilever height (hc) (3.2mm, 4mm) thick and the distal connector ( c) (0.4mm, 1.5mm and 2mm). The group were divided into control (cc 12mm; hc 4mm and c 1.5), Group 1 (cc 12mm; hc 4mm, 0.4mm c), Group 2 (cc 12 mm; hc 3.2mm, 0.4mm and c) Group 3 (cc 12 mm; hc 3.2mm, 1.5mm c), Group 4 (cc 19mm; hc 4mm, 1.5mm c), Group 5 (cc 19mm; hc 4mm, 0.4mm c), Group 6 (cc 19mm; hc 3.2mm, 1.5mm c), Group 7 (cc 19mm; hc 3.2mm, 0.4mm c), Group 8 (cc 26mm; hc 4mm, 1.5mm c), Group 9 ( cc 26mm; hc 4mm, 0.4mm c) Group 10 (cc 26mm; hc 3.2mm, 1.5mm c) and Group 11 (cc 26mm; hc 3.2mm, 0.4mm and c). All specimens were subjected to compression test in a universal testing machine with 5000N load cell and constant speed of 0.5 mm / min. Data were analyzed by ANOVA statistical analysis three criteria, followed by Tukey test, with significance level was 5% (p <0.05). a significant difference in the decrease of resistance to compression with increasi ng length of the cantilever, a significant increase in resistance groups with height greater cantilevers was observed. It was concluded smaller length and greater height of cantielver, the greater the resistance. Already the connector thickness influenced the resistance, but without uniformity. / Doutor
48

Análise das tensões em próteses implantossuportadas esplintadas, variando o tipo de conexão protética e a inclinação do implante : estudo pelo método dos elementos finitos tridimensionais não linear /

Almeida, Daniel Augusto de Faria. January 2015 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Fellippo Ramos Verri / Banca: Humberto Gennari Filho / Banca: Paulo Renato Junqueira Zuim / Banca: Joel Ferreira Santiago Júnior / Banca: Regina Tamaki / Resumo: O comportamento biomecânico de um implante dentário osseointegrado desempenha um importante papel na sua longevidade funcional. As limitações anatômicas às vezes tornam necessário o posicionamento de implantes com angulações fora do considerado ideal para as reabilitações protéticas, havendo maior concentração de tensões e reabsorção no osso cortical ao redor do implante. Para solucionar tais situações o profissional deve lançar mão de um cuidadoso planejamento, estudando qual conexão protética melhor se adapta a situação clínica. Portanto, este estudo objetivou avaliar a influência da esplintagem e da inclinação de implantes (0º, 17º e 30º) em reabilitações de maxila posterior, na distribuição de tensões pelo método dos elementos finitos tridimensionais não linear. Para isso, foram confeccionados 12 modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Os modelos foram compostos por 3 implantes de hexágono externo (4,1 mm) ou cone morse (4,0 mm) nas regiões: 14 - 10 mm; 15 - 8,5 mm; 16 - 8,5 mm suportando próteses de 3 elementos unitárias ou esplintadas. Após geração das geometrias, os modelos foram importados para o programa de pré e pós-processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 400N axialmente e 200N obliquamente, divididas em cada cúspide das superfícies oclusais. Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos NeiNastran versão 9.2, executada em uma estação de trabalho. Os resultados foram importados novamente ao FEMAP 10.2 para visualização e pós-processamento dos mapas de tensão de von Mises e tensão máxima principal. Os resultados... / Abstract: The performance of an osseointegrated dental implant plays important rule for functional longevity of the rehabilitation. Sometimes, anatomical limitations imply in the positioning of tilted implants that is not considered ideal for prosthetic rehabilitation, generating higher stress concentration around it and leading to cortical bone resorption. To solve these situations, the professional must plan carefully the restoration and to study the connection type of the implant to better adaption for these situations. In this way, this study aimed to evaluate the influence of splinting prostheses and implant inclination (0º, 17º and 30º) in implant-supported prostheses in the posterior region of the maxilla on stress distribution by non-linear 3D finite element analysis. For this, twelve 3D models was confectioned using modeling software SolidWorks 2010 and Rhinoceros 4.0 and software InVesalius. The models constituted of 3 dental implants of external hexagon or morse taper (4,0 mm) at the regions: 14 - 10mm; 15 - 8,5 mm; 16 - 8,5 mm, supporting three-unit prostheses in single and splinting configurations. After modeling, the models were imported to pre- and post-processing software of finite elements FEMAP 10.2 for finite element mesh generation and configuration of restrictions and loading conditions. Axial load of 400N and oblique of 200N were applied divided on each cusp tip of occlusal surface. Next step, it was the analysis configuration on FEMAP 10.2 that was exported to NeiNastran 9.2 to math processing. After, the files of results were imported to FEMAP 10.2 to results visualization and post-processing analysis by plotting von Mises and maximum principal stress maps. The results of bone tissue showed higher stress concentration to inclined implants of external hexagon supporting single crowns under oblique loading. The models with splinted Morse taper... / Doutor
49

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four /

Pimentel, Gustavo Henrique Diniz. January 2014 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Marco Antônio Compagnoni / Banca: Janaína Habib Jorge / Banca: Estevam Augusto Bonfante / Banca: Ricardo Faria Ribeiro / Resumo: O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar "in vitro" a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema "All-on-four"). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate "in vitro" the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating "All-on-four" system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below) / Doutor
50

Avaliação da influência da inclinação das cúspides e da direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas : estudo através do método dos elementos finitos tridimensionais /

Antenucci, Rosse Mary Falcón January 2008 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Coelho Goiato / Banca: Pedro Yoshito Noritomi / Resumo: Apesar do uso do implante dental ser um procedimento clínico largamente utilizado, não esta isento de complicações mecânicas, que podem produzir falha nas próteses ou nos implantes. Portanto, é essencial otimizar a distribuição da carga mastigatória através das próteses e destas para os implantes e osso suporte. O propósito do presente estudo foi realizar uma análise pelo método dos elementos finitos tridimensionais para avaliar a influência da inclinação das cúspides e direção das cargas oclusais na distribuição das tensões em próteses implanto-suportadas. Foram elaborados 5 modelos mandibulares com o auxilio dos programas de desenho assistido Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) e com o auxílio de um scanner 3D MDX-20 (Roland DG, São Paulo, Brasil); por meio destes simularam-se um bloco de osso mandibular (osso cortical e osso esponjoso), com a presença de um implante unitário de 3,75x10 mm (Conexão Master Screw, São Paulo, Brasil) com coroa metalo-cerâmica com 3 diferentes inclinações das cúspides (10°, 20° e 30°). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEiNastran® 9.0 (Noran Engineering, Inc., EUA), para determinação das regiões, incorporação das propriedades de cada material, geração da malha e análise. Foi aplicada uma carga oblíqua (45°) de 200 N, fracionada em 2 pontos (100 N) nas vertentes triturantes das cúspides vestibulares da coroa metalo-cerâmica e posteriormente uma carga axial (0°) de 200 N, distribuida em 4 pontos (50 N) nas v ertentes internas da coroa metalo-cerâmica. Os resultados foram visualizados por meio dos mapas de tensão de von Mises e mostraram que os valores mais altos de tensão para o implante foram no modelo de 30° de in clinação das cúspides... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Although, osseointegrated implant is a clinical procedure longer used. It is not trouble-free. Therefore, is essential optimizing the occlusal loading through the prostheses to implants and supporting bone. A Threedimensional (3D) finite element analysis was performed to evaluate the influence of cuspal inclination and occlusal loading direction on stress distribution in implant-supported prostheses. Three-dimensional finite element models were simulated by means of Rhinoceros® 3D 3.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA) programs and the scanner 3D MDX-20 (Roland DG, São Paulo, Brazil). A mandibular section of bone with an implant and its superstructures were simulated in this study. A 1-piece 3.75 x 10 mm screw-shape (Conexão Master Screw, São Paulo, Brazil) dental implant system, embedded in trabecular bone with 1 mm of cortical bone surrounding and crown with 3 different cuspal inclinations (10°, 20° and 30°). Three-dimensional models were transferred to the NEiNastran® 9.0 (Noran Engineering, Incorporation, USA.) software, in which, material properties were incorporated and mesh and analysis generated. Oblique loading (200 N) was applied on chewing surfaces of buccal cuspid. After, vertical loading (200 N) was applied on internal surfaces of the cuspids. According to the results, it was observed, higher stress values was showed in the model with 30° of c uspal inclination; in cortical bone the higher stress was showed in the model with 10° of cuspal inclination. Oblique and axial loading produce maximum stress concentrations at the point of load application. It was concluded that: An increasing in the cuspal inclination increased stress in the osseointegrated implant and decreased the stress in cortical bone and Oblique loading increased the general stress in 100% in relation to axial loading. / Mestre

Page generated in 0.1249 seconds