• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 103
  • 1
  • Tagged with
  • 104
  • 104
  • 104
  • 104
  • 104
  • 87
  • 64
  • 62
  • 61
  • 59
  • 54
  • 49
  • 39
  • 25
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Teixeira, Wendel 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.
82

Avaliação in vitro da transmissão de carga oclusal em próteses sobre implantes em função da inclinação de implantes através de análise fotoelástica / In vitro evaluation of occlusal load transmission in prosthetic implant according to the inclination of implants by photoelastic analysis

Takeshita, Edson Koji 01 September 2011 (has links)
A técnica All-on-Four foi idealizada visando diminuir a extensão do cantilever nas reabilitações de pacientes edêntulos com próteses implantossuportadas. Contudo, ainda persistem questionamentos relacionados ao comportamento biomecânico dos implantes e da própria técnica All-on-Four, posto que, questões como a perda óssea peri-implantar e falência de componentes da prótese ainda não estão claramente elucidadas. O objetivo da pesquisa foi avaliar a dissipação de tensões em próteses implantossuportadas dos tipos Branemark e All-on-Four, sob carga oclusal estática, e o papel do lado de balanceio e do comportamento do complexo implantes/próteses. Foram confeccionadas seis réplicas de mandíbula humana em resina fotoelástica, divididas em dois grupos:um com quatro implantes dispostos axialmente e paralelas entre si no espaço interforaminal (mandíbulas Branemark), e outro com quatro implantes inseridos de acordo com a técnica All-on-Four. Confeccionou-se uma prótese total implantossuportada, de maneira que se adaptasse em todas as seis mandíbulas. O experimento foi conduzido com o auxílio de um dispositivo giratório de carga, que permitiu a visualização das mandíbulas por todos os ângulos, sem alteração da carga aplicada. Após a fixação padronizada do corpo de prova no dispositivo, a prótese foi parafusada sobre os implantes da mandíbula. Os carregamentos de carga foram feitos em três pontos: no cantilever da prótese, no primeiro pré-molar e na incisal dos incisivos centrais inferiores. Para cada ponto de aplicação das cargas, fotografaram-se as mandíbulas nos lados de trabalho, de balanceio e na linha mediana, vestibular e na linha mediana também por lingual. Pelos resultados observados, quando as cargas foram aplicadas em regiões mais anteriores da prótese, as tensões nos implantes distais inclinados atenuaramse e as outras regiões da mandíbula apresentaram tensões menores e melhor distribuídas. As franjas também mostraram que a angulação dos implantes distais promoveu mudanças no eixo de rotação do conjunto implantes/prótese. Assim como verificou-se que o implante mais distal do lado de balanceio mostrou atuação conjunta com o implante distal do lado de trabalho nas mandíbulas com implantes axiais e, o mais distal do lado de balanceio nas mandíbulas com implantes inseridos segundo a técnica All-on-Four, mostrou tensão nos ápices, denotando função de estaca. Pela metodologia empregada foi possível concluir que, uma prótese total implantossuportada, segundo a técnica All-on-Four, apresentou melhor melhor dissipação das cargas oclusais e o lado de balanceio teve papel fundamental no auxílio à dissipação de cargas oclusais. / The All-on-Four technique was conceived in order to decrease the length of the cantilever in the rehabilitation of edentulous patients with implant-supported prosthesis. However, still persist questions related to the biomechanical behavior of implants and the proper technique All-on-Four, since issues such as peri-implant bone loss and failure of the prosthetic components are not yet clearly elucidated. The purpose of the study was to evaluate the dissipation of tensions in the Branemark implant-supported prosthesis and All-on-Four, under static occlusal load, and the role of the balancing side and the complex behavior of implants / prostheses. Six replicas of the human mandible were made in photoelastic resin, divided into two groups: one with four implants placed axially and parallel to each other in interforaminal space (Branemark jaws), and another four implants inserted according to the All-on-Four technique. It was made an implant-supported denture, so that would fit in all six jaws. The experiment was conducted with the aid of a rotating load device, which permitted visualization of the jaws from all angles, without changing the applied load. After the standardized setting of specimen in the device, the prosthesis was screwed onto the implants in the jaw. The cargo shipments were made on three points: the cantilever prosthesis, in the first premolar and the lower central incisor incisal. For each point of application of loads, photograph was taken from the work sides of the jaws, balancing and the midline, bucal view and the midline lingual also. By the observed results, when loads were applied to more anterior regions of the prosthesis, the stresses in the distal inclined implants attenuated and other regions of the mandible showed lower stresses and better distributed. The fringes also showed that the angulation of the distal implants promoted changes in the axis of rotation of the implant / prosthesis. As it was found that the most distal implantat on the balancing side showed joint action with the distal implant of the working side in the jaw with axial implants, and the most distal implant on the balancing side of jaw with implants inserted according to All-on Four technique, the tension showed apices, denoting stake function. For the methodology it was concluded that an implant-supported denture, according to the All-on-Four technique, had a better dissipation of occlusal loads and balancing side was fundamental hole in helping to dissipate occlusal loads.
83

Avaliação da tensão gerada em intermediários e região peri-implantar simulada após aperto de parafusos para fixação de infraestruturas confeccionadas por duas técnicas CAD/CAM e convencional / Evaluation of strain generated in abutments and peri-implant simulated region after tightening screws on frameworks made by conventional and two CAD/CAM techniques

Braga, Adriana de Castro Oliveira Pereira 27 August 2013 (has links)
A passividade tem sido descrita como um requisito importante para a longevidade de restaurações implanto-suportadas e, na busca incessante por materiais e técnicas que desempenhem um melhor resultado biomecânico para este tipo restauração, surgem os métodos baseados em desenho e manufatura auxiliados por computador, os chamados métodos CAD/CAM. Assim, o objetivo deste estudo foi comparar o desenvolvimento de tensão provocado pela fixação, por meio do aperto de parafusos, de infraestruturas confeccionadas por duas técnicas CAD/CAM e pela técnica convencional da cera perdida. Para a realização do experimento, foi confeccionado um modelo em poliuretano com dois implantes hexágono externo posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) infraestruturas em Ni-Cr fundidas pela técnica convencional da cera perdida; (U) infraestruturas em zircônia confeccionadas pela técnica CAD/CAM de usinagem e (S) infraestruturas em Co-Cr confeccionadas pela técnica CAD/CAM de sinterização a laser. Durante o aperto dos parafusos para fixação das infraestruturas, as tensões geradas foram registradas por extensômetros unidos aos intermediários e material de osso simulado. De acordo com a técnica utilizada e considerando todos os diferentes locais avaliados, os valores médios de tensão variaram de: 14,28 μξ a 693,40 μξ para o Grupo C; 19,27 μξ a 930,92 μξ para o Grupo U e 5,37 μξ a 196,57 μξ para o Grupo S. Análise de variância a dois critérios para as variáveis técnica de confecção de infraestruturas e local de avaliação da tensão demonstrou que não houve diferença estatisticamente significante entre os valores de tensão em relação à técnica utilizada. Por outro lado, os valores foram significantemente diferentes em relação aos diferentes locais analisados. Desta forma, este estudo concluiu que as duas técnicas CAD/CAM testadas não proporcionaram infraestruturas com passividade superior às obtidas convencionalmente e que todas as peças apresentaram certo grau de desadaptação e consequente falta de homogeneidade na distribuição de tensões pelo sistema. / Passivity property has been described as an important requirement for the longevity of implant-supported restorations. Looking for materials and techniques that provide better biomechanical outcome for such restorations, methods based on design and computer aided manufacturing has emerged, the called CAD/CAM techniques. Therefore, the aim of this study was to compare the strain development during tightening screws on frameworks made from two CAD/CAM techniques and conventional lost wax technique. For the experiment, a polyurethane model with two external hexagon implants, placed at 43 and 45 teeth areas, was made. From this model, 12 three-unit frameworks were produced and divided into 3 groups (n = 4) according to the technique used: (C) Ni-Cr cast frameworks produced by lost wax conventional technique; (U) zirconia frameworks prepared by CAD/CAM milling technique and (S) Co-Cr frameworks prepared by CAD/CAM laser sintering technique. Generated strains, during tightening screws, were recorded by strain gauges attached to abutments and simulated bone material. According to the technique used, which considered, all different sites evaluated, mean strain values ranged from: 14,28 μξ to 693,40 μξ for Group C; 19,27 μξ to 930,92 μξ for Group U and 5,37 μξ to 196.57 μξ for Group S. Two way ANOVA performed for frameworks technique and strain sites demonstrated no statistically significant difference between strain values in relation to the technique used. On the other hand, values were statistically different for distinct sites analyzed. Furthermore, this study concluded that the two CAD/CAM techniques tested did not provide frameworks with better passivity than conventionally obtained ones and that all parts showed some degree of mismatch and consequent lack of homogeneity related to stresses distribution through the system.
84

Análise da distribuição de tensão em protocolo mandibular confeccionado pelo sistema convencional e CAD/CAM, variando tipo, número e inclinação dos implantes / Stress distribution analysis of mandibular protocol confectioned by the conventional system and cad/cam, ranging type, number and inclination of the implants

Sbardelotto, Cristian 19 January 2016 (has links)
As próteses totais fixas implantossuportadas tem ganhado cada dia mais seu espaço no tratamento reabilitador de pacientes edêntulos, pois se trata de uma forma de tratamento que atende todos os quesitos funcionais e estéticos. Ainda não existe na literatura um consenso de qual a configuração que melhor distribui as tensões aos implantes e tecidos adjacentes. O objetivo deste estudo foi comparar as tensões geradas na interface osso-implante de próteses totais mandibulares implantossuportadas através do método de correlação de imagens digitais (CID). Foram analisadas duas configurações diferentes quanto a quantidade e posicionamento de implantes (4 ou 5 implantes), diferentes conexões [hexágono externo (HE) e cone morse (CM)] e barras para prótese fixa implantossuportada obtidas por fundição convencional e usinadas pelo sistema CAD/CAM. Foram confeccionados modelos em poliuretano, utilizando implantes de 3,75x11mm, divididos em 8 grupos: G1 (5 implantes/HE/CAD-CAM), G2 (5 Implantes/CM/CAD CAM), G3 (5 Implantes/HE/Convencional), G4 (5 Implantes/CM/Convencional), G5 (4 Implantes/HE/CAD CAM), G6 (4 Implantes/CM/CAD CAM), G7 (4 Implantes/HE/Convencional) e G8 (4 Implantes/CM/Convencional). A análise por CID foi feita quantitativamente e qualitativamente, com aplicação de carga de 250N na fossa central do primeiro molar inferior, onde foram estabelecidas diferentes regiões de interesse para a análise, sendo denominadas de C1 (cervical 1) e A1 (apical 1) para região distal ao último implante, C2 (cervical 2) e A2 (apical) para região mesial ao último implante. Foram encontradas diferenças estatisticamente significantes para o número de implantes em todas as regiões analisadas [C1 (p=0,002), A1 (p=0,01), C2 (p=0,001), A2 (p=0,004)], para as conexões foram encontradas diferenças na região C2 (p<0,05) e para as barras na região A2 (p=0,003). De acordo com os resultados pode-se concluir que as prótese com 4 implantes apresentaram maior quantidade de tensões por tração nas regiões apicais, não houve diferença significativa na concentração de tensões para as conexões HE e CM, exceto para a região C2, onde houve maior concentração de tensão para conexão CM e em comparação ao método de obtenção das barras, as barras convencionais apresentaram maior concentração de tensões de tração nas próteses com 5 implantes. / The implant-supported fixed dental prostheses have been used to rehabilitate edentulous patients as it fulfills not only functional aspects but also esthetic questions. Literature shows that there is no consensus about the best configuration to distribute stress to the implants and surrounding tissues. The objective of this study was to compare the stress generated at the boneimplant interface of implant-supported mandibular dentures by a digital image correlation method (DIC). Two different configurations were analyzed for the implants quantity and position (4 or 5 implants), different connections [external hexagon (EH) and Cone Morse (CM)] and bars for implant-supported fixed prosthesis obtained by conventional casting and machined by CAD/CAM system. Models were prepared from polyurethane and implants (3.75x11mm) were divided in 8 groups: G1 (5 implants/EH/CAD-CAM), G2 (5 Implants/CM/CAD-CAM), G3 (5 Implants/EH/Conventional) , G4 (5 Implants/CM/Conventional), G5 (4 Implants/EH/CAD-CAM), G6 (4 Implants/CM/CAD-CAM) G7 (4 Implants/EH/Conventional) and G8 (4 Implants/CM/Conventional). DIC analysis were quantitative and qualitatively made with a 250N load at first molar central fossa, which were established in different regions of interest for analysis as C1 (cervical 1) and A1 (apical 1) to distal to the last implant, C2 (cervical 2) and A2 (apical) for mesial region to the last implant. Statistically significant differences were found for number of implants in all regions examined [C1 (p=0.002), A1 (p=0.01), C2 (p=0.001) and A2 (p=0.004)], for connections differences were found in the C2 region (p <0.05) and for the bar region at A2 (p=0.003). According to the results it can be concluded that the prosthesis with four implants showed a higher stress at the apical regions, there was no significant difference in the concentration of stress for EH and CM connections, except for the C2 region, where there was a higher concentration of stress for CM connection, and comparing bars obtained methods, conventional bars showed a higher concentration of stresses in prosthesis with 5 implants.
85

Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention force

Aguiar Junior, Fábio Afrânio de 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
86

Análise da distribuição de tensão em protocolo mandibular confeccionado pelo sistema convencional e CAD/CAM, variando tipo, número e inclinação dos implantes / Stress distribution analysis of mandibular protocol confectioned by the conventional system and cad/cam, ranging type, number and inclination of the implants

Cristian Sbardelotto 19 January 2016 (has links)
As próteses totais fixas implantossuportadas tem ganhado cada dia mais seu espaço no tratamento reabilitador de pacientes edêntulos, pois se trata de uma forma de tratamento que atende todos os quesitos funcionais e estéticos. Ainda não existe na literatura um consenso de qual a configuração que melhor distribui as tensões aos implantes e tecidos adjacentes. O objetivo deste estudo foi comparar as tensões geradas na interface osso-implante de próteses totais mandibulares implantossuportadas através do método de correlação de imagens digitais (CID). Foram analisadas duas configurações diferentes quanto a quantidade e posicionamento de implantes (4 ou 5 implantes), diferentes conexões [hexágono externo (HE) e cone morse (CM)] e barras para prótese fixa implantossuportada obtidas por fundição convencional e usinadas pelo sistema CAD/CAM. Foram confeccionados modelos em poliuretano, utilizando implantes de 3,75x11mm, divididos em 8 grupos: G1 (5 implantes/HE/CAD-CAM), G2 (5 Implantes/CM/CAD CAM), G3 (5 Implantes/HE/Convencional), G4 (5 Implantes/CM/Convencional), G5 (4 Implantes/HE/CAD CAM), G6 (4 Implantes/CM/CAD CAM), G7 (4 Implantes/HE/Convencional) e G8 (4 Implantes/CM/Convencional). A análise por CID foi feita quantitativamente e qualitativamente, com aplicação de carga de 250N na fossa central do primeiro molar inferior, onde foram estabelecidas diferentes regiões de interesse para a análise, sendo denominadas de C1 (cervical 1) e A1 (apical 1) para região distal ao último implante, C2 (cervical 2) e A2 (apical) para região mesial ao último implante. Foram encontradas diferenças estatisticamente significantes para o número de implantes em todas as regiões analisadas [C1 (p=0,002), A1 (p=0,01), C2 (p=0,001), A2 (p=0,004)], para as conexões foram encontradas diferenças na região C2 (p<0,05) e para as barras na região A2 (p=0,003). De acordo com os resultados pode-se concluir que as prótese com 4 implantes apresentaram maior quantidade de tensões por tração nas regiões apicais, não houve diferença significativa na concentração de tensões para as conexões HE e CM, exceto para a região C2, onde houve maior concentração de tensão para conexão CM e em comparação ao método de obtenção das barras, as barras convencionais apresentaram maior concentração de tensões de tração nas próteses com 5 implantes. / The implant-supported fixed dental prostheses have been used to rehabilitate edentulous patients as it fulfills not only functional aspects but also esthetic questions. Literature shows that there is no consensus about the best configuration to distribute stress to the implants and surrounding tissues. The objective of this study was to compare the stress generated at the boneimplant interface of implant-supported mandibular dentures by a digital image correlation method (DIC). Two different configurations were analyzed for the implants quantity and position (4 or 5 implants), different connections [external hexagon (EH) and Cone Morse (CM)] and bars for implant-supported fixed prosthesis obtained by conventional casting and machined by CAD/CAM system. Models were prepared from polyurethane and implants (3.75x11mm) were divided in 8 groups: G1 (5 implants/EH/CAD-CAM), G2 (5 Implants/CM/CAD-CAM), G3 (5 Implants/EH/Conventional) , G4 (5 Implants/CM/Conventional), G5 (4 Implants/EH/CAD-CAM), G6 (4 Implants/CM/CAD-CAM) G7 (4 Implants/EH/Conventional) and G8 (4 Implants/CM/Conventional). DIC analysis were quantitative and qualitatively made with a 250N load at first molar central fossa, which were established in different regions of interest for analysis as C1 (cervical 1) and A1 (apical 1) to distal to the last implant, C2 (cervical 2) and A2 (apical) for mesial region to the last implant. Statistically significant differences were found for number of implants in all regions examined [C1 (p=0.002), A1 (p=0.01), C2 (p=0.001) and A2 (p=0.004)], for connections differences were found in the C2 region (p <0.05) and for the bar region at A2 (p=0.003). According to the results it can be concluded that the prosthesis with four implants showed a higher stress at the apical regions, there was no significant difference in the concentration of stress for EH and CM connections, except for the C2 region, where there was a higher concentration of stress for CM connection, and comparing bars obtained methods, conventional bars showed a higher concentration of stresses in prosthesis with 5 implants.
87

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Murillo Sucena Pita 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
88

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Wendel Teixeira 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.
89

Força de mordida em pacientes com fissura labiopalatina reabilitados com próteses parciais fixas sobre dentes naturais e implantes / BITE FORCE IN PATIENTS WITH REHABILITATED CLEFT LIP AND PALATE WITH PARTIALLY FIXED PROSTHESES ON NATURAL TEETH AND IMPLANTS

Tavano, Rafael D'Aquino 31 July 2015 (has links)
As fissuras palatinas além de envolvem o osso alveolar podem promover a ausência do dente incisivo lateral ou apresenta-lo severamente comprometido. Nesses casos sua reabilitação poderá ser feita por próteses parciais fixas convencionais ou por prótese sobre implantes, geralmente após uma cirurgia de enxerto ósseo na região. Todavia além da estética, se faz necessário investigar sobre o potencial de força oclusal que essas reabilitações proporcionam. Assim, o propósito desse estudo foi avaliar a força máxima de mordida em indivíduos com fissura labiopalatina unilateral reabilitados com prótese parcial fixa convencional e sobre implantes e comparar esses resultados com o lado contralateral e com indivíduos sem fissura. A amostra foi constituída por 50 indivíduos, 25 pacientes com fissura (15 reabilitados com próteses parciais fixas convencionais e 10 sobre implantes) e 25 indivíduos sem fissura com dentes naturais. A força de mordida máxima foi mensurada por um único examinador utilizando o gnatodinamômetro, registrado nas regiões reabilitadas de incisivo lateral e canino, região de molares e incisivos centrais. Os valores médios obtidos, e a análise estatística com os testes t de Student e t de Student pareado permitiram observar que no mesmo indivíduo, a força de mordida do lado não afetado foi estatisticamente superior quando comparado com o lado da fissura reabilitado com prótese (p=0,005). O grupo reabilitado com prótese fixa convencional apresentou a força máxima de mordida estatisticamente igual ao grupo com prótese fixa sobre implante (p=0,781). Considerando os grupos experimental e controle na região de molares os resultados foram estatisticamente iguais (lado afetado p=0,082 e não afetado p=0,066). Na região de incisivo lateral e canino, o lado correspondente ao afetado no grupo-controle, apresentou força máxima de mordida estatisticamente maior que o grupo-experimental (p=0,004), enquanto no lado correspondente ao não afetado os resultados foram iguais. Na região de incisivos centrais o resultado médio do grupo-controle também foi estatisticamente maior que o experimental (p=0,005) / The cleft palate involving the alveolar bone may have the lateral incisor tooth missing or severely compromised. In such cases rehabilitation can be done through fixed dental prostheses or implant-supported fixed dental prostheses, generally after a bone graft surgery in the region. However, beyond aesthetics, it is necessary to investigate the potential for occlusal force that these rehabilitations provide. Thus, the purpose of this study was to evaluate the maximum bite force in subjects with unilateral cleft lip and palate rehabilitated with fixed dental prostheses or implantsupported fixed dental prostheses and compare the results with the contralateral side and with individuals without cleft. The sample consisted of 50 subjects, 25 patients with cleft (15 rehabilitated with fixed dental prostheses and 10 with implant-supported fixed dental prostheses) and 25 individuals without cleft and with natural teeth. The maximum bite force was measured by means of gnathodynamometer, registered in the rehabilitated lateral incisor and canine region, molars region and incisors regions by a single examiner. The obtained average values, and the statistical analysis with the Student t test and paired Student t test allowed to be observed that on the same individual the bite force on the side that was not affected was statistically superior when compared to the side of the rehabilitated cleft with prosthesis (p=0,005). The rehabilitated group with conventional prostheses presented maximum bite force statistically equal to the group with the implant-supported fixed dental prostheses (p=0,781). Considering the experimental and control groups on the molar regions, the results were statistically equal (affected side p=0,082 e non-affected p=0,066). The lateral incisor and canine region from the correspondent affected side on the control group presented maximum bite force statistically higher than the experimental group (p=0,004), on the non-affected side the results were the same. In the incisor region, the average result of the control group was also statistically higher than the experimental group (p=0,005)
90

Análise comparativa da interface entre intermediários e estruturas fundidas e CAD/CAM em Co-Cr e zircônia antes e após queima de cerâmica e ciclagem mecânica / Comparative analysis of the interface between different abutments and casted or CAD/CAM prostheses before and after ceramic firing and behavior after mechanical cycling.

Coró, Vitor 05 July 2013 (has links)
As próteses sobre implantes apresentam alto índice de sucesso, mas ainda existem relatos de complicações técnicas e mecânicas, principalmente em relação à adaptação e desaperto de parafusos. Técnicas CAD/CAM foram desenvolvidas tentando melhorar adaptação e passividade, e hoje existem vários materiais e sistemas como opção de trabalho. A proposta deste estudo foi avaliar, por meio de leitura em microscópio, a adaptação de próteses de três elementos sobre dois implantes confeccionadas em diferentes materiais, por diferentes técnicas, antes e após a queima de cerâmica. Também foi verificado se o método/material utilizado, assim como o grau de adaptação influenciariam no comportamento das peças frente a um ensaio de fadiga mecânica. Foram formados 5 grupos de 10 amostras (n=10). Após leituras, prensagem de cerâmica e ensaio de fadiga, os dados foram submetidos aos testes ANOVA e Tuckey-Kramers. As médias de desajuste vertical pré e pós aplicação da cerâmica (&mu;m), quando ambos parafusos apertados foram para G1: Estruturas fundidas em Co-Cr com cilindros calcináveis (26,03 ± 18,4) e (36,5 ± 9) G2: Estruturas sobrefundidas em liga de Co-Cr, utilizando cilindros com base de Co-Cr (4,86 ± 5) e (10,5 ± 6); G3: Estruturas fundidas em liga de Co-Cr, associadas à técnica do cilindro cimentado (0 ± 0)e (0 ± 0); G4: Estruturas usinadas em Co-Cr CAD/CAM (0 ± 0) e (2,7 ± 2);G5: Estruturas usinadas em Zircônia CAD/CAM (14,87 ± 9) e (15,2 ± 8). Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado parafusado, os resultados foram para G1: 9,63 ± 1 e 34,8 ± 8; G2: 2,37 ± 5 e 11,9 ± 9; G3: 0 ± 0 e 0 ± 0; G4: 0 ± 0 e 3,4 ± 3; G5: 17,69 ± 1 e 20,8 ± 9. Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado desparafusado, os resultados foram para G1: 124,22 ± 37 e 129,8 ± 37; G2: 64,79 ± 47 e 80,6 ± 46; G3: 12,34 ± 17 e 2,1 ± 3; G4: 3,54 ± 5 e 17,6 ± 8; G5: 37,77 ± 25 e 42,4 ± 19. O torque de desaperto (Ncm) dos parafusos protéticos foi verificado antes e após ensaio de fadiga com 300.000 ciclos. Os valores médios encontrados foram respectivamente: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. Os grupos CC, Co-Cr CAD/CAM e Zi, apresentaram os melhores resultados quanto ao ajuste vertical, seguidos pelo grupo Co-Cr e calcinável. Os grupos CC, Co-Cr e Co-Cr CAD/CAM apresentaram perda de torque dos parafusos protéticos após oensaio de fadiga mecânica. O grupo Zi teve menor perda de torque entretodos grupos, comparando antes e após o teste de fadiga. Nenhum dos grupos apresentou perda de torque suficiente para que a prótese perdesse estabilidade da junção. / The implant-supported prostheses present a high success rate, but there are still reports of technical and mechanical complications, mainly regarding adaptation and loosening of screws. CAD/CAM techniques have been developed trying to improve adaptation and passivity, and today there are many options of materials and systems to work with. The purpose of this study was to evaluate, by microscope, fitting of three elements prostheses retained by two implants, made of different materials, different techniques, before and after ceramic firing. It was also verified if the method/material used, as well as the degree of adjustment would influence on the behavior of the prostheses after a fatigue test. Five groups of ten specimens were formed (n = 10). After reading, ceramic pressing and fatigue test data were submitted to ANOVA and Tukey-Kramer\'s tests. The mean vertical misfit pre and post application of ceramic (&mu;m), whit both screws tightened to G1: Structures casted in Co-Cr with castable cylinders (26.03 ± 18.4) and (36.5 ± 9) G2: Structures casted in Co-Cr, with Co-Cr basis cylinder (4.86 ± 5) (10.5 ± 6); G3: Structures casted in Co-Cr associated with the cemented cylinder technique (0 ± 0) and (0 ± 0); G4: Machined structures in Co-Cr CAD/CAM (0 ± 0) and (2.7 ± 2), G5: Structures machined in zirconia CAD/CAM (14.87 ± 9) and (15.2 ± 8). To the measurement condition of only one side tighted, pre and post ceramic, on the tightned side, the results were G1: 9.63 ± 1 and 34.8 ± 8; G2: 2.37 ± 5 and 11.9 ± 9; G3: 0 ± 0 and 0 ± 0; G4: 0 ± 0 and 3.4 ± 3; G5: 17.69 ± 1 and 20.8 ± 9. To the measurement condition of only one side tightened, pre and post ceramic, on the untightened side, the results were in G1: 124.22 ± 37 and 129.8 ± 37; G2: 64.79 ± 47 and 80.6 ± 46; G3: 12.34 ± 2.1 and 17 ± 3; G4: 5 ± 3.54 and 17.6 ± 8; G5: 37.77 ± 25 and 42.4 ± 19. The loosening torque of the prosthetic screws (Ncm) was checked before and after fatigue test to 300,000 cycles. The mean values were: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. CC groups, Co-Cr CAD/CAM and Zi, showed the best results regarding vertical adjustment, followed by the Co-Cr group and castable. CC groups, Co-Cr and Co-Cr CAD/CAM presented loss of torque after fatigue test. The Zi group showed less loss of torque among all groups, comparing before and after fatigue test. None of the groups showed enough loosening to loose joint stability.

Page generated in 0.1612 seconds