Spelling suggestions: "subject:"prótese dentária."" "subject:"prótese identária.""
221 |
Efeito do uso contínuo de um protocolo de polimento mecânico no controle das alterações de superfície em dentes artificiais de resina acrílica / Effect of continuous use of a mechanical polishing protocol on the control of surface changes in artificial acrylic resin teethBarreto, Joel Oliveira 20 February 2017 (has links)
BARRETO, J. O. Efeito do uso contínuo de um protocolo de polimento mecânico no controle das alterações de superfície em dentes artificiais de resina acrílica. 2017. 54 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2017. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-05-11T16:23:40Z
No. of bitstreams: 1
2017_dis_jobarreto.pdf: 5072997 bytes, checksum: 767ea3d12e8b041627c64af5f2d96969 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-05-11T16:23:49Z (GMT) No. of bitstreams: 1
2017_dis_jobarreto.pdf: 5072997 bytes, checksum: 767ea3d12e8b041627c64af5f2d96969 (MD5) / Made available in DSpace on 2017-05-11T16:23:49Z (GMT). No. of bitstreams: 1
2017_dis_jobarreto.pdf: 5072997 bytes, checksum: 767ea3d12e8b041627c64af5f2d96969 (MD5)
Previous issue date: 2017-02-20 / Acrylic resin is widely used for prosthodontics fabrication. Despite its many advantages, some changes in properties such as color stability and surface roughness can occur over the period of its use by the patients. In order to minimize those modifications, polishing procedures can be performed on the prosthesis’ surface, increasing its longevity and clinical performance and making them less susceptible to the action of external agents such as alimentary liquids and cleaning solutions. The aim is to evaluate the effect of a mechanical polishing protocol performed regurlarly in biofilm adhesion, surface roughness, color stability and mass of acrylic resin artificial teeth. Sixty upper central incisors were divided into two groups according to the immersion liquid (n=30) - distilled water and coffee; and these two groups subdivided into three subgroups (n = 10): A - only immersion; B – immersion associated with a fortnightly polishing; C – immersion associated with a monthly polishing. Mechanical polishing was performed using an aluminium oxide polishing paste and wheel of felt coupled to a manual engine at 3000 rpm for 5 seconds, at intervals of time simulating 15 and 30 days of daily consumption of coffee. Surface roughness, color and weight of the artificial teeth were evaluated before and after the interventions in intervals simulating 4, 8, 12 and 24 months. After this, it was assessed the adhesion of a Candida albicans and Streptococcus mutans biofilm in all groups. Results: After immersion in coffee, the specimens showed a significant increase in surface roughness and weight. The color changes observed for this group was significantly greater when compared with the group immersed in water. The tested polishing procedure reduced the roughness of the material and controlled the stains caused by coffee without losing mass, being the fortnightly frequency more effective than the monthly in controlling these changes. Also, the adhesion of biofilm was significantly reduced in the groups immersed in coffee after the polishing, being the fortnightly the most effective in controlling the amount of biofilm. Conclusion: When performed regularly, the mechanical polishing tested reduces the changes suffered by artificial teeth subjected to immersion in coffee, being the fortnightly frequency more effective in controlling the changes in the properties evaluated in this study. / A resina acrílica é um material amplamente utilizado na confecção de próteses dentárias. Entretanto, apesar de suas inúmeras vantagens, está sujeita às alterações de propriedades, como cor e rugosidade de superfície, ao longo do período de uso pelos pacientes. Com o intuito de minimizar essas alterações, aumentando a longevidade e o desempenho clínico, procedimentos de polimento são realizados nas superfícies das próteses dentárias, tornando-as menos susceptíveis à ação de agentes, como líquidos alimentares e soluções higienizadoras, dentre outros. O objetivo deste trabalho é avaliar o efeito de um protocolo de polimento mecânico realizado de forma frequente na rugosidade de superfície, estabilidade de cor, adesão de biofilme e massa de dentes artificiais em resina acrílica. Sessenta incisivos centrais superiores foram divididos em dois grupos, de acordo com o líquido de imersão (n=30): água destilada e café; e estes, subdivididos em três subgrupos (n=10): A – apenas imersão; B – imersão associada ao polimento quinzenal; C – imersão associada ao polimento mensal. O polimento mecânico foi realizado por meio de pasta à base de óxido de alumínio e roda de feltro acoplada a um motor manual em uma rotação de 3000 rpm, em intervalos de tempo simulando 15 e 30 dias de consumo diário de café. Rugosidade de supefície, cor e massa dos dentes artificiais foram avaliadas antes das intervenções e após intervalos simulados de 4, 8, 12 e 24 meses. Ao final, foi avaliado o padrão de adesão de biofilme misto de Candida albicans e Streptococcus mutans, em todos os grupos. Após imersão em café, os dentes artificiais apresentaram um aumento significativo nos valores de rugosidade e massa. A diferença de coloração observada nesse grupo foi significativamente maior que a ocorrida no grupo imerso em água. O polimento testado reduziu a rugosidade de superfície do material e controlou o manchamento causado pelo café, sem causar perda relevante de massa, sendo o polimento quinzenal mais efetivo que o mensal em controlar essas alterações. Também, a adesão de biofilme foi significativamente reduzida após os polimentos nos grupos imersos em café, sendo o polimento quinzenal mais efetivo em controlar a maior adesão de biofilme provocada pela imersão na solução alimentar testada. O polimento testado, quando realizado de forma frequente, reduz as alterações sofridas pelos dentes artificiais submetidos à imersão em café, sendo a frequência quinzenal mais efetiva no controle das alterações nas propriedades avaliadas neste estudo.
|
222 |
Avaliação de métodos de instalação de implantes e prótese imediata definitiva que utiliza imagens de tomografia computadorizada e sistema computacionais – CAD/CAM / Evaluation of a protocol for dental implant placement and immediate definitive prosthesis using computer tomography and CAD-CAM systemsDi Giacomo, Giovanni de Almeida Prado [UNIFESP] 25 May 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:33Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-05-25 / Objetivos: Avaliar a precisão e as complicações do uso de guias cirúrgicas feitas por Sinterização Seletiva a Laser para a colocação de implante dentário sem retalho e a instalação imediata de prótese definitiva. Método: 62 implantes e 12 próteses imediatas definitivas foram instalados em 12 pacientes (8 mulheres e 4 homens) com idade média de 60,3 anos. Os desvios laterais (coronal e apical) e angular entre as imagens dos implantes planejados e colocados foram medidos. Os pacientes foram acompanhados por 30 meses, e as complicações cirúrgicas e protéticas foram registradas. Resultados: As médias ± desvios-padrão foram: 6,53° ± 4,31° para o desvio angular, 1,35 ± 0,65 mm para o desvio coronal, e 1,79 ± 1,01 mm. Desvios coronal e apical menores que 2,0 mm foram observados em 82,67% e 58,33% dos implantes, respectivamente. A taxa de complicação foi de 34,4% e incluiu dano aos tecidos moles, inserção de implante com dimensão maior que o planejado, dor, perda de implante, desvio da linha média da prótese e fratura da prótese. As taxas de sucesso acumuladas foram de 98,33% para os implantes, e de 91,66% para as próteses. Conclusão: Dentro da amostra estudada, houve diferença estatisticamente significante entre a posição das imagens dos implantes no planejamento e as imagens dos implantes na tomografia computadorizada pós-operatória. Foram registrados 34,41% de complicações decorrentes dos procedimentos de instalação de implantes dentários com cirurgia assistida por computador utilizando guia cirúrgica feita por SLS e instalação de prótese imediata definitiva. / Purpose: to evaluate the accuracy and complications of the use of selective laser sintering surgical guides for flapless dental implant placement and immediate definitive prosthesis installation. Methods: Sixty implants and 12 immediate definitive prosthesis were installed in 12 patients (8 females and 4 four males; mean age 60.3- range 41-71 years). Lateral (coronal and apical) and angular deviation between virtually planned and placed implant were measured. The patients were followed for 30 months and surgical and prosthetic complications were registered. Results: The mean angular deviation (±standard deviation) was 6.53º (4.31), coronal deviation was 1.35 (0.65) mm and apical deviation was 1.79 (1.01) mm. Coronal and apical deviation lower than 2,0 mm were observed in 82.67% and 58.33% of the implants, respectively. The rate of complication was 34.4% and included: pulling of the soft tissue from the lingual surface, insertion of wider implant than planned, unstable implant, prolonged pain, midline deviation of the prosthesis, prosthesis fracture. The cumulative survival rate was 98.33% for implants and 91.66% for prosthesis. Conclusion: The present study showed lateral deviation lower than 1.8 mm in average and angular deviation in mean 6.53º. But 41.67% of the implants had apical deviation greater than 2.0 mm. The rate of complications was 34.41%. In spite of inaccuracies and complications, high cumulative survival rate was observed for both implants and prosthesis. Hence, computer-aided dental implant surgery still requires improvement and should be considered as being in the developmental stage. / TEDE / BV UNIFESP: Teses e dissertações
|
223 |
Qualidade de vida e fatores clínicos associados a percepção da dificuldade de higienização em pacientes com reabilitações implantossuportadasCorrêa, Bruna Barbosa January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:59:31Z (GMT). No. of bitstreams: 1
339548.pdf: 1778406 bytes, checksum: 14d38cce515eae77c2aaa49537a1daad (MD5)
Previous issue date: 2016 / O objetivo deste estudo foi identificar as associações das variáveis sócio demográficas, de satisfação e clínicas com o grau de dificuldade de higienização em pacientes com reabilitações implantossuportadas. Foram examinados 183 pacientes, reabilitados com 910 implantes, entre 1998 e 2012. Todos os implantes encontravam-se em função há pelo menos 1 ano, na fase protética definitiva. Foram coletados e registrados nos prontuários, dados relacionados à idade, sexo, localização (anterior; posterior), gengiva artificial (ausente; presente), tipo de prótese (unitária; parcial; total; overdenture), tempo de prótese (=5; >5 anos) e diagnóstico (saudável; doença peri-implantar). Além disso, os pacientes responderam a um questionário ? Dental Impact on Daily Living (DIDL) que avalia a satisfação com o tratamento. O DIDL possui 36 questões distribuídas em cinco dimensões: aparência, dor, conforto, desempenho e mastigação. O instrumento gera uma pontuação total final, além de pontuações para cada dimensão. O teste qui-quadrado de Pearson foi utilizado para avaliar as associações entre sexo, idade, variáveis clínicas e de satisfação com a dificuldade de higiene. Idade e sexo mostraram associação com a dificuldade de higiene (p<0,001 e p=0,001, respectivamente). Em relação à satisfação, apenas conforto e satisfação total apresentaram resultados estatisticamente significativos (p=0,005 e p=0,006, respectivamente). Para as variáveis clínicas, presença de gengiva artificial, tipo e tempo de prótese mostraram associação positiva com a dificuldade de higiene (p=0,001, p<0,001 e p=0,006, respectivamente). Pacientes com mais de 50 anos, sexo feminino, presença de gengiva artificial, próteses totais fixas e tempo de prótese =5 anos foram associados à dificuldade de higienização das reabilitações implantossuportadas. Associações positivas também foram encontradas em relação ao conforto e satisfação total.<br> / Abstract : The aim of this study was to identify associations of sociodemographic, satisfaction and clinics variables with the difficulty of hygiene in patients with implant rehabilitations. One hundred eighty-three patients rehabilitated with 910 implants in function for at least 1 yearwere examined.Data related to age, sex, location (anterior; posterior), artificial gingiva (absent; present), type of prosthesis (single; fixed parcial; fixed or removable full-arch restoration), time in function (=5; >5 years) and diagnosis (health; peri-implant disease) were collected and documented in the medical records. In addition, patients answered a questionnaire ? Dental Impact on Daily Living (DIDL), which assesses satisfaction with treatment. The DIDLconsists of 36 items that aregrouped intofive dimensions: appearance, pain, comfort, general performanceand eating restriction.The instrument generates a total final score, in addition to scores for each dimension.The Pearson?s chi-square test was used to assess associations between age, sex, clinical variables and satisfaction with the oral hygiene difficulty. Age and sex showed association with the oral hygiene difficulty of (p<0.001 and p=0.001, respectively). Regarding satisfaction, only comfort and total satisfaction presented statistically significant results (p=0.005 and p=0.006, respectively). For the clinical variables, artificial gingiva, type of prosthesis and time in function showed positive association with the difficulty of hygiene (p=0.001, p<0.001 and p=0.006, respectively). Patients older than 50 years of age, female, presence of artificial gingiva, complete fixed prosthesis and time in function =5 years were associated with hygiene difficultyon implant rehabilitation. Positive associations were also found in relation to comfort and total satisfaction.
|
224 |
Influência de tratamentos de superfície e agentes cimentantes na sobrevivência de coroas de Y-TZP recobertas por porcelanaAnami, Lilian Costa [UNESP] 28 May 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:27Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-05-28. Added 1 bitstream(s) on 2015-09-17T15:45:36Z : No. of bitstreams: 1
000844478.pdf: 5986811 bytes, checksum: f316ca1188ee9b7817cf579a46c759fd (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente estudo foi investigar a influência de diferentes tratamentos da superfície interna de coroas e de diferentes agentes cimentantes na sobrevivência de coroas de zircônia parcialmente estabilizada por óxido de ítrio (Y-TZP) recobertas por porcelana. Inicialmente foi realizado um estudo de elementos finitos onde foram comparados os valores e a distribuição das Tensões Máxima Principal (TMP) de espécimes flat e anatômicos, com variações na anatomia dos componentes cerâmicos (coroas de Y-TZP e porcelana, com e sem ponto de contato, com e sem desenho modificado da Y-TZP para suporte da porcelana). As geometrias produzidas em software CAD (Computer-aided design) foram importadas para software de análise de elementos finitos. Foi realizado carregamento pontual e vertical de 200 N sobre o nó central dos modelos. O padrão da distribuição da TMP foi bastante similar entre os modelos estudados, com concentração importante de tensões na zona de singularidade. Considerando a dificuldade de padronização na confecção de espécimes anatômicos durante ensaios laboratoriais, a escolha do modelo simplificado (flat) pode ser justificada. Em uma segunda etapa foram usinados 90 preparos flat em resina epóxica que receberam coroas com infraestrutura em Y-TZP confeccionadas pelo sistema CAD/CAM e recobertas com porcelana pela técnica estratificada. Seis condições foram testadas (n=15): para coroas cimentadas com cimento resinoso Panavia F, quatro diferentes tratamentos foram avaliados (limpeza com álcool isopropílico [PC], aplicação de glaze [POG], jateamento com Al2O3 125 μm [POA]; jateamento com partículas de óxido de alumínio revestidas por sílica de 30 μm [PCJ]); para as coroas cimentadas com cimento de ionômero de vidro (CIV) e de fosfato de zinco (CFZ), as superfícies foram limpas com álcool isopropílico. A resistência à fadiga foi avaliada... / The aim of this study was to investigate the influence of different treatments of the inner surface of crowns and different luting agents on the survival of crowns made of zirconia partially stabilized by yttrium oxide (YTZP) and porcelain. A first study was performed using finite element analysis, where we compared the values and the distribution of Maximum Principal Stresses (MPS) of flat and anatomical specimens, with variations in the anatomy of ceramic components (crowns composed of Y-TZP and porcelain, with and without contact point, with and without a modified design of Y-TZP supporting the porcelain). The geometries produced in CAD software (Computer-Aided-Design) were imported for a finite element analysis software. A punctual and vertical load of 200 N was carried out on the central node of the models. The MPS distribution was quite similar among the studied models with important stress concentration in the singularity zone. Considering the lack of standardization in the preparation of anatomical specimens for laboratory tests, the choice of the simplified model (flat) could be justified. In a second step, 90 flat preparations were machined in epoxy resin and received crowns with Y-TZP infrastructure made by CAD/CAM system and veneered with porcelain by the stratified technique. Six conditions were tested (n=15): for crowns cemented with Panavia F, four different treatments were evaluated (cleaning with isopropyl alcohol [PC], overglaze application [POG], sandblasting with 125 μm particles of Al2O3 [POA]; sandblasting with 30μm particles of SiO2 [PCJ]); for crowns cemented with glass ionomer cement (CIV) and zinc phosphate (CFZ), the inner surface were cleaned with isopropyl alcohol. The fatigue resistance was evaluated by the number of mechanical cycles required for fracture of the specimens through stepwise loads methodology. Samples were cycled for 5,000 cycles at 200 ...
|
225 |
Resistência de união entre um cimento resinoso e uma cerâmica aluminizada submetida a diferentes tratamentos de superfícieSoares, Luiz Felipe [UNESP] 13 May 2003 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:23:51Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-05-13. Added 1 bitstream(s) on 2015-12-10T14:29:50Z : No. of bitstreams: 1
000200273.pdf: 2866168 bytes, checksum: e0e29948223b178226a3c83ec2622980 (MD5) / Este estudo avaliou a resistência de união entre um cimento resinoso e uma cerâmica submetida a três tratamentos de superfície. Foram confeccionados cinco blocos cerâmicos (Procera AIICeram), com dimensões de 6mm X 6mm X 15mm. Cada bloco foi seccionado em três porções (6mm X 6mm X 5mm). Os quinze blocos obtidos foram duplicados em resina composta (W3D Master) e a superfície cerâmica foi polida com lixas n° 600, 800 e 1200. Os blocos divididos em três grupos experimentais: Grupo 1 - Jateamento com Al2O3 110µm; Grupo 2 - Sistema Rocatec: Rocatec-Pre + Rocatec-Plus + Rocatec-Sil; Grupo 3 - Sistema CoJet: jateamento com partículas especiais de sílica 30µm + ESPE-SiL Os blocos cerâmicos foram cimentados aos de resina composta com o cimento resinoso Panavia F, conforme as instruções do fabricante, sob carga de 750g por 10min. Os blocos cimentados foram armazenados (água destilada/37°C/7 dias) e seccionados em dois eixos, x e y, com disco diamantado sob refrigeração, obtendo-se corpos-de-prova (n=30) com 0,6 ± 0,1 mm2 de área adesiva. Cada cp foi fixado em um paquímetro adaptado para o teste de microtração e o ensaio realizado (velocidade: 1mm.min-1) em máquina de ensaio universal (EMIC DL-1000). Os dados obtidos foram submetidos à análise de variância e teste de Tukey. Os valores médios de resistência de união (MPa) foram: Grupo 1 - 12,70 ± 2,6; Grupo 2-17,06 ± 3,9; Grupo 3 - 18,52 ± 4,72. G2 e G3 apresentaram resistência de união estatisticamente maior que G1. Não houve diferença estatística significante entre G2 e G3 (p<0,05) / This study evaluated the tensile bond strength of a resin cement to a ceramic after to three ceramic surface treatments. Five blocks of Procera AIICeram (6 mm X 6 mm X 15 mm) were fabricated. Each ceramic block was sectioned in 3 portions of 6 mm X 6 mm X 5 mm. The fifteen blocks were duplicata in resin composite (W3D Master); the ceramic surface was polished through 600, 800 and 1200 SiC grids, and the blocks were divided in 3 experimental groups: Group 1- Sandblasting with 110 µm Al203; Group 2- Rocatec System: Racatec-Pre, Plus and -Sil; and Group 3 - CoJet System: Sandblasting with 30µm silica particles + ESPE-Sil. The ceramic blocks were cemented to the resin composite blocks with resin cement (Panavia F), according to manufacturer's instructions, under a load of 750g for 10min. The cemented blocks were stored in 37°C distilled water for 7 days and sectioned in two axes, x and y, with a diamond disk under cooling water in order to obtain samples (sp) with a bonding area of 0,6 ± 0,1 mm2 (n=30). Each sp was attached to an adapted device for the microtensile test. This set was attached to a universal testing machine (EMIC DL-1000) and tested at crosshead speed of 1mm.min-1. The data were statisfically analyzed using ANOVA and Tukey's test. The bond strength mean values (MPa) were: Group 1- 12.70; Group 2- 17.06 and Group 3- 18.52. G2 and G3 showed statistically significant higher bond strength values than G1. There was no statistical difference between G2 and G3 (p<0,05)
|
226 |
Estudo da resistência à tração de cápsulas e troqueis metálicos cimentados, em função de alívio e retenção para o cimentoPavanelli, Carlos Augusto [UNESP] 08 May 2002 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:24:27Z (GMT). No. of bitstreams: 0
Previous issue date: 2002-05-08. Added 1 bitstream(s) on 2015-12-10T14:30:39Z : No. of bitstreams: 1
000164795.pdf: 4680235 bytes, checksum: 7ff12a7d0689d90c62b277df5ac9ca92 (MD5) / O objetivo desta pesquisa foi estudar resistência à tração de cápsulas cimentadas sobre troqueis metálicos, com cimento fosfato de zinco, variando quantidade de alívio interno nas cápsulas e sulcos horizontais nas cápsulas e nos troqueis. Foram torneados duzentos e oitenta e oito cilindros de aço inoxidável, representativos de cento e quarenta e quatro troqueis e igual quantidade de cápsulas, semelhantes a preparos e respectivas coroas totais, em Torno tipo CNC (Controle Numérico Computadorizado). As dimensões padronizadas dos troqueis foram: 9mm de diâmetro na base maior (cervical); 8mm de altura cérvico-oclusal: terminação em ombro com um milímetro de largura e 135° de inclinação; e 10° de conicidade nas paredes axiais. As cápsulas foram obtidas por usinagem do interior de outros cilindros, com a forma idêntica e negativa em relação à forma dos troqueis. Quarenta e oito condições experimentais foram estabelecidas e cimentadas, em três réplicas para cada condição. O alívio das cápsulas foi de 2µm (na condição sem alívio), 30µm e 60µm (nas condições com alívio). A confecção de sulcos variou entre zero e três sulcos, nas cápsulas e nos troqueis, com 200µm de profundidade e em quantidades iguais de espécimes para cada condição estudada. Assim, as condições experimentais somente se repetiram nas réplicas. Os corpos-de-prova obtidos das cimentações foram submetidos a teste de tração em máquina universal de ensaios Emic (ltaquaquecetuba-SP), no Departamento de Materiais e Tecnologia da Faculdade de Engenharia de Guaratinguetá, UNESP. Os resultados receberam tratamento estatístico pelos métodos de, Análise de Variância e de Tukey, mostrando diferença significativa ao nível de 5% para as variáveis alívio e sulco nas cápsulas individualmentee quando esses fatores interagiram. Não houve diferença estatística para a variável sulco nos troqueis. A permaneceu sem alteração com os... / The objective of this study was to verify tensile strength of metallic capsules and dies, in stainless steel, cemented with zinc phosphate cement, representative of crowns and full crowns preparations. One hundred and forty four dies and respective capsules were made in Lathe CNC (Computer Numeric Control). The dimensions of the dies were: 9mm of diameter ín the base (gingival); 8mm of height; cervical line in shoulder with one millimeter of width and 135 degrees of inclination; and tapered of 10 degrees. The capsules were excavated in the interior of other cylinders, with the tapered form, identical and negative in relation to the form of the dies. Forty-eight experimental conditions, in three rejoinders each, were made. The changeable were: internal relief in the capsules; and horizontal sulcus in the capsules and the dies. The relief varied between 2µm (in the condition without relief), 30µm and 60µm (in the conditions with relief). The sulcus varied between no sulcus and three sulcus, as much in the capsules as in the dies, with 200 µm depth, in equal amounts of specimens for each condition of sulcus. The capsules and dies were cemented. The experimental conditions were not repeated, except in the rejoinders. The specimens were submitted to traction test in universal test machine of Emic (ltaquaquecetuba-SP) in the Department of Materials and Technology of the College of Engineering of Guaratinguetá, UNESP. The data were submitted to statistic analysis for methods ANOVA and Tukey, showing significant dífference for the variable relief and sulcus in the capsules, and interacting individually and among then. They had not presented difference statistics for changeable the sulcus in the dies. The tensile strength increased with the relief and the amount of sulcus in the capsules, but it remained in the same level with the sulcus in the dies
|
227 |
Avaliação do uso de uma estrutura de nylon modificada como reforço de prótese totalmente acrílica implantossuportadaGonçalves, Fernanda de Cássia Papaiz [UNESP] 03 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:15Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-12-03. Added 1 bitstream(s) on 2016-04-01T18:01:15Z : No. of bitstreams: 1
000860671.pdf: 2218695 bytes, checksum: eb80ba359b0f6e3cf6bd8c9c2dcef065 (MD5) / O estudo avalou o comportamento de uma estrutura de nylon experimental com o propósito de ganho na resistência mecânica do material e ainda, na melhor distribuição de forças em toda extensão da prótese ao longo eixo dos implantes diminuindo o risco de fraturas e falhas neste sistema e, consequentemente maior longevidade. Para isso considerou-se próteses do tipo protocolo sem barra metálica, com e sem incorporação de reforço (nylon), variando a extensão da região do cantilever até primeiro molar/ segundo pré-molar (n=6). Os corpos de prova foram submetidos à análise de deformação por extensometria (extensometria s) e carga de 30 kg, e ao teste de carga máxima à fratura na EMIC (1000 kgf, 2 mm/min). Pode-se concluir que a incorporação da estrutura de reforço aumentou os valores de carga máxima independentemente da extensão do cantilever, além de apresentar menores valores de micro deformação ao redor de todos os implantes. As extensões de cantilever em pré-molar (5mm) além de apresentarem os menores valores de micro deformação quando comparadas a extensão em molar (15mm) também mostraram os maiores valores de carga máxima à fratura. / The study evaluated the behavior of a new compound of experimental nylon fiber, with the purpose of increasing the mechanical strength of the material and improving the strain distribution to the fullest extent of the prosthesis to the long axis of the implants reducing the risk of fractures and faults in the system and therefore increasing longevity. For this considered protocol type prostheses without metal bar, with and without incorporating reinforcement (nylon), varying the extent of the region of the cantilever to the first molar / second premolar (n = 6). The samples were subjected to analysis by extensometer strain (extensometria ) and load of 30 kg, and the maximum load test to fracture the EMIC (1000 kgf, 2 mm / min). It can be concluded that the incorporation of reinforcing mesh increased maximum load values regardless of the extent of the cantilever, and exhibit lower values microstrain around all implants. The cantilever extensions in premolar (5 mm) in addition of having the smallest microstrain values compared the extent to molar (15mm) also showed the highest maximum load values to fracture
|
228 |
Estudo comparativo das tensões e microdeformações ao redor de pilares protéticos microunit e ucla sob carregamento axial estáticoSantis, Leandro Ruivo de [UNESP] 03 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:16Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-12-03. Added 1 bitstream(s) on 2016-04-01T18:01:17Z : No. of bitstreams: 1
000860699.pdf: 2264641 bytes, checksum: 4f5c8ea2c3254608562a9141ab7a55ca (MD5) / O objetivo deste estudo in vitro foi comparar a microdeformação e a concentração de tensões ao redor de implantes, geradas por cargas axiais estáticas, em pilares protéticos microunit e ucla, por meio da extensometria e fotoelasticidade. Foram confeccionados dois blocos em poliuretano, sendo inseridos três implantes de hexágono externo em cada. Os implantes do primeiro bloco receberam pilares protéticos microunit e, nos implantes do segundo bloco, foram instalados pilares protéticos ucla. As respectivas coifas plásticas foram posicionadas sobre os pilares protéticos microunit. As coifas plásticas microunit e ucla foram adaptadas a uma estrutura em resina padronizada e fundidas em liga Ni-Cr. Os blocos foram duplicados em resina fotoelástica. As supraestruturas metálicas foram parafusadas sobre os respectivos pilares protéticos. Os blocos fotoelásticos foram submetidos a uma carga axial de 7,5 kgf usando um dispositivo de aplicação de carga adaptado em polariscópio. Foram colados quatro extensômetros na superfície superior de cada bloco em poliuretano, tangenciando cada um dos implantes. Foi utilizado um dispositivo de aplicação de cargas com carga axial de 30 kgf sobre os pontos A, B e C, durante 10 segundos. Os dados obtidos foram analisados estatisticamente através do teste RM ANOVA dois fatores e teste post hoc de Sidak (p<0,05). Os pilares protéticos ucla apresentaram menores valores médios de microdeformação (597,8 με), quando comparado aos pilares protéticos microunit (988,3 με). O fator pilar foi estatisticamente significante (p <0,0001), o ponto de aplicação da carga não foi estatisticamente significante (p = 0,9437). Os pilares protéticos ucla mostraram padrões de distribuição de tensão semelhantes aos pilares protéticos microunit. O padrão de distribuição das tensões foi diferente no ponto de aplicação de carga B. Em conclusão, a p presença de pilar prótetico convencional interferiu.... / The aim of this in vitro study was to compare microstrain and stress development around implants during axial loading, varying abutment type and load application point, using strain gauge and photoelastic analysis. Two polyurethane blocks were made, being inserted three external hexagon implants each. Microunit abutments were screwed on the first block and UCLA abutments were screwed on the second block. The respective plastic copings were installed onto the microunit abutments. The plastic copings and UCLA abutments were adapted to a standard resin pattern and cast in Ni-Cr alloy. The blocks were replicated in photoelastic resin. The metallic structures were screwed into the microunit abutments and into the implant plataform, respectively. The photoelastic blocks were submitted to a static vertical 7,5 kgf load using a load application device adapted on polariscope. Four strain gauges were bonded to the surface of each polyurethane block, tangetially to each implant. A static vertical 30 kgf load was applied for 10 seconds, using a load application device on points A, B and C. The data were analyzed by two-way RM ANOVA and Sidak's post hoc test (p< 0.05). Ucla abutments showed lower microstrain mean values (597,8 με) when compared to microunit abutments (988,3 με). The abutment factor was statistically significant (p<0.0001), load application point wasn't statistically significant (p=0,9437). UCLA system showed similar stress distribution patterns to conventional abutments. The pattern of stress distribution was different at point B. In conclusion, the presence of conventional prosthetic pillar interfered in stress distribution and microstrain development
|
229 |
Comportamento mecânico de sistemas prótese/implante em região dos elementos finitos e interferometria holográficaCorrêa, Cássia Bellotto [UNESP] 27 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-03-27Bitstream added on 2014-06-13T19:03:10Z : No. of bitstreams: 1
correa_cb_dr_arafo_parcial.pdf: 89265 bytes, checksum: 4a9f9dd3b7ecf7d11e40eb08c7e14aa7 (MD5) Bitstreams deleted on 2015-04-01T12:51:10Z: correa_cb_dr_arafo_parcial.pdf,Bitstream added on 2015-04-01T12:51:46Z : No. of bitstreams: 1
000718624.pdf: 1088386 bytes, checksum: 7f7f102af3a1904fba4df74fc0d9c96d (MD5) / A proposta deste estudo foi analisar, por meio do método de elementos finitos (MEF), o comportamento mecânico das estruturas envolvidas em uma reabilitação implanto suportada de 4 elementos na região anterior de maxila, utilizando apenas 2 implantes, variando os posicionamentos dos implantes e o tipo de conexão protética (hexágono externo, hexágono interno e cone-Morse) e ainda validar metodologia de análise computacional por meio da interferometria holográfica, uma técnica experimental. Modelos tridimensionais baseados em um banco de tomografias computadorizadas foram criados para todas as situações estudadas (Implantes nos Incisivos Laterais - IL; Implantes nos Incisivos Centrais - IC e Implante no Incisivo Central e Incisivo Lateral - ILIC). Uma carga equivalente à 150N foi aplicada a 45° na região de cíngulo de cada elemento dentário. Para a validação da metodologia de elementos finitos por meio da interferometria holográfica, criou-se um modelo prototipado com as mesmas situações estudadas e comparou-se os deslocamentos direcionais resultantes da aplicação de 3 intensidades de força. Como resultado foi observado: o menor deslocamento da estrutura protética e maior deslocamento na estrutura óssea no grupo IC. No tecido ósseo, a tensão de von Misses localiza-se predominantemente na região cortical. O valor máximo de tensão de von Misses foi observado no implante vizinho ao cantilever no grupo ILIC. Na conexão cone Morse, o parafuso protético mostrou metade da tensão de von Misses em relação a conexão hexágono interno e hexágono externo. Comparando-se os deslocamentos direcionais nas duas metodologias, verificou-se que havia uma correlação positiva entre os resultados, porém os valores obtidos experimentalmente eram superiores aos do modelo computacional. Pode-se concluir... / The purpose of this study was to analyze, by finite element method (FEM), the mechanical behavior of structures involved in an implant supported rehabilitation of 4 elements in the anterior maxilla, using only 2 implants, varying the placements of the implants and prosthetic connection types (external hexagon, internal hexagon and Morse taper) Moreover to validate the methodology of MEF by holographic interferometry, an experimental technique. Three-dimensional models based on a database CT scans were created for all situations studied (Implants in Lateral Incisors - IL; Implants in Central Incisors IC and Implant in Central e Lateral Incisor - ILIC). An equivalent load of150N was applied at 45° in the cingulum of each tooth. To validate the finite element method by Holographic Interferometry, a prototyped model was created with the same situations studied and compared the directional displacements, resulting from the application of the 3 intensities of force. As results it was observed: the lowest prosthetic displacement structure and greater displacement in the bone structure in the IC group. In bone tissue, the von Mises stress is located predominantly in the cortical region. The maximum value of von Mises stress was observed in the implant neighboring to cantilever in the group ILIC. In Morse taper connection, the prosthetic screw showed half the von Misses stress in relation to internal and external hexagon connection. Comparing the directional displacement in both methodologies, an positive correlation between the results was found, although the experimentally values obtained were higher than those of the computational model. It can be concluded that the placement of implants and prosthetic connection type have influence in the intensity and distribution of stress/strain on the implant-supported rehabilitation of anterior... (Complete abstract click electronic access below)
|
230 |
Efeito da guia de desoclusão pelo canino, em compraração á oclusão balanceada bilateral, sobre a satisfação e parâmetros cinesiográficos em usuários de próteses totaisPaleari, André Gustavo [UNESP] 14 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-08-14Bitstream added on 2014-06-13T20:25:45Z : No. of bitstreams: 1
paleari_ag_dr_arafo.pdf: 822160 bytes, checksum: 5bf213c70bb1f7f3f2ad86329efb6a1b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivos: O objetivo deste estudo foi comparar os efeitos da desoclusão pelo canino, em comparação à oclusão balanceada bilateral, sobre a satisfação e parâmetros cinesiográficos de usuários de próteses totais, por meio de um estudo “cross-over”. Material e Métodos: Cinquenta pacientes desdentados receberam novas próteses totais bimaxilares. Após ajustes intra-orais e um período de adaptação, 44 participantes foram incluídos no estudo e receberam aleatoriamente uma sequência de esquemas oclusais: oclusão balanceada bilateral seguida de desoclusão pelo canino, ou desoclusão pelo canino seguida de oclusão balanceada bilateral. As avaliações foram realizadas após 30 dias de cada esquema oclusal. Os participantes responderam a um questionário de satisfação com as próteses e um cinesiógrafo registrou os movimentos mandibulares fisiológicos e o movimento da prótese total maxilar durante a mastigação. O teste de Wilcoxon e o teste t de Student foram utilizados para comparar os níveis de satisfação e os dados cinesiográficos para cada esquema oclusal, respectivamente (α = 0,05). Resultados: Os resultados não mostraram diferenças entre os esquemas oclusais em relação à satisfação dos participantes e em nenhum dos parâmetros cinesiográficos avaliados, exceto para a intrusão vertical da prótese maxilar durante a mastigação, que foi 0,1mm menor com a desoclusão pelo canino. Conclusão: Pode-se concluir que: 1) A satisfação de pacientes desdentados com as próteses totais não é influenciada pelo esquema oclusal; 2) Os movimentos mandibulares de abertura e fechamento, o espaço funcional livre e os movimentos da mandíbula durante a mastigação não são alterados em função da utilização da oclusão balanceada bilateral ou desoclusão pelo canino; 3) A desoclusão pelo canino promove menor intrusão da prótese total superior, embora... / Objectives: The objective of this study was to compare the effects of canine guidance and bilateral balanced occlusion on satisfaction and kinesiographic parameters of complete denture wearers, by means of a cross-over trial. Material and Methods: Fifty edentulous patients received new maxillary and mandibular complete dentures. After the intraoral adjustments and adaptation period, 44 participants were enrolled in the trial and randomly received a sequence of occlusal schemes: bilateral balanced occlusion followed by canine guidance, or canine guidance followed by bilateral balanced occlusion. The evaluations were performed after 30 days of each occlusal scheme. Participants answered a denture satisfaction questionnaire and a kinesiograph instrument recorded mandibular physiologic movements and pattern of maxillary denture movement during chewing. Wilcoxon test and paired sample t-test were used to compare satisfaction levels and kinesiographic data for each occlusal scheme, respectively (α= .05). Results: The results showed no differences between occlusal schemes on participant’s satisfaction and in any of the kinesiographic parameters studied, except for the vertical intrusion of the maxillary complete denture during chewing, which was .1mm lower with canine guidance. Conclusion: It can be concluded that: 1) The satisfaction of edentulous patients with theirs dentures is not influenced by occlusal scheme; 2) The mandibular movements of opening and closing, the freeway space and the jaw movement during chewing are not altered by the use of the bilateral balanced occlusion or canine guidance in their dentures, 3) The canine guidance promotes less intrusion of the maxillary complete dentures, although the values found are not clinically relevant; 4) The canine guidance or bilateral balanced occlusion are appropriate occlusal scheme and recommended for making... (Complete abstract click electronic access below)
|
Page generated in 0.0743 seconds