• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 710
  • 37
  • 37
  • 37
  • 37
  • 28
  • 9
  • 8
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 728
  • 728
  • 357
  • 269
  • 232
  • 185
  • 141
  • 141
  • 123
  • 118
  • 107
  • 105
  • 89
  • 80
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Estudo da distribuição das tensões internas, pelo método dos elementos finitos, em uma raiz com um retentor intra-radicular pré-fabricado, rosqueado e com fenda apical

Nishioka, Renato Sussumu [UNESP] 02 December 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-12-02Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000125820.pdf: 4215530 bytes, checksum: c94e418847a698de05079aaae2d7ccab (MD5) / A análise dos elementos finitos foi utilizada para estudar o papel de um pino pré-fabricado, rosqueado e bi-partido (Flexi-post) sobre a tensão na dentina de um dente tratado endodonticamente. Um modelo tridimensional da secção mésio-distal de um incisivo central superior, sem restauração, foi analisado pelo MSC/NASTRAN (MacNeal/Schwendler), programa de análises, executado em um microcomputador. O modelo foi discretizado em 48.954 elementos finitos assimétricos, definidos por 10.355 nós. Para cada elemento, foi transferido uma única propriedade elástica para representar os materiais modelados. Homogeneidade, isotropia e elasticidade linear foi atribuída para todo o material. Uma carga estática de l00N foi aplicada sobre o bordo incisal do pino; no sentido vertical, obliquo a 45 graus, horizontal e uma simulação sem carga. O Critério Máximo de Escoamento e a tensão de Von Mises foram calculados. Utilizando-se as análises do elemento modelado e empregado nesse estudo, o seguinte pode ser concluído a respeito do pino rosqueado bi-partido (Flexi-post): A tensão máxima principal na dentina foi localizada na área cervical e no ápice do pino. As roscas apicais do pino não redirecionam as tensões para a raiz / A finite element analysis was carried out to study the role of prefabricated threaded split shaft post (Flexi-post) on dentinal stress in pulpless tooth. Three dimensional plane strain models of mesio-distal section of a human maxillary central incisor without restoration was analysed with the MSC/NASTRAN(MacNea/Schwendler) general purpose finite analysis program was executed on a microcomputer. The model was '' discretized into 48.954 axisymmetric finite elements defined by 10.355 nodes. Each element was assigned unique elastic properties to represent the materials modeled. Homogeneity, isotropy and linear elasticity were assume for ali material. A static load of 100 N was applied to the incisal edge of the post; vertical, at 45 degrees angle, horizontal and one simulation without load . Maximal principal stresses and von Mises equivalent stress were calculed. Using the element analysis model employed in this study, the following can be concluded concerning threaded split shaft post (Flexi-post): Maximum principal stresses in dentin were located at cervical place and at the post apex. The apical threads of the post not redirecting stresses away from the root
242

Avaliação da resistência adesiva entre um cimento resinoso e ligas para metalo-cerâmica submetidas a dois diferentes condicionamentos de supefície

Andreatta Filho, Osvaldo Daniel [UNESP] 12 December 2005 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-12Bitstream added on 2015-01-26T13:30:14Z : No. of bitstreams: 1 000436713.pdf: 7731647 bytes, checksum: 9b7aadb95aa028efeda85c7c4760387c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a hipótese de que diferentes condicionamentos de superfície de três ligas para próteses metalo-cerâmica (Ouro - Degudent U – Degussa; Níquel-Cromo - Wiron 99, Bego; Titânio - Rematitan, Dentaurum) não alteram os valores de resistência adesiva com um cimento resinoso. Vinte blocos de cada liga com dimensões de 5x5x5mm foram fundidos e divididos em dois subgrupos de 10 blocos e condicionados com os seguintes tratamentos de superfície: TRAT. 1 (Primer) – jateamento com partículas de óxido de alumínio 110µm (Al2O3) + Alloy Primer (Kuraray, CO) e TRAT. 2 (Cojet)– jateamento com partículas de sílica com o sistema Cojet (3M/ESPE) + Silano ESPE-Sil (3M/ESPE). Os blocos condicionados de cada grupo foram cimentados com Panavia F (Kuraray, CO) a blocos de resina composta ClearfilTM AP-X (Kuraray, CO) sob carga constante de 750g por 10 minutos. Foram determinados, portanto, seis grupos experimentais constituídos por conjuntos formados pela liga, cimento e resina composta. Estes foram cortados em uma máquina de corte obtendo-se por bloco cimentado 4 amostras com dimensões de 10x1x1mm sendo que a superfície adesiva apresentou aproximadamente 1mm2 de área. O teste de microtração foi realizado em máquina de testes universal (EMIC) com célula de carga de 10kgf e velocidade de 1mm/min. Cada grupo foi representado por quarenta amostras, entretanto cada grupo apresentou 10 valores médios de resistência adesiva em MPa (n=10), sendo que cada valor foi proveniente da média obtida a partir dos valores individuais das quatro amostras de cada conjunto de blocos cimentados. Os valores de resistência adesiva e os desvios-padrão (MPa) para os grupos foram : G1: 7,33 ± 1,93d; G2: 13,35 ± 2,18 c G3: 23,56 ± 6,5 b; G4:42,6 ± 5,84 a; G5: 26,17 ± 1,94 b; G6: 44,30 ± 2,3 a. Os dados de resistência adesiva foram analisados estatisticamente pelo teste de .... / The aim of this study is to evaluate the hypothesis that different conditionings of surface of three dental alloys (Gold - Degudent U – Degussa; Nickel-chromium - Wiron 99, Bego; Titanium - Rematitan, Dentaurum) they do not modify the values of bond strength with a resin cement. Twenty blocks of each alloy with dimensions of 5x5x5mm were cast and divided in two subgroups of 10 blocks that were conditioned with the following surface treatments: TRAT. 1 – sandblasting with particles of oxide of aluminum 110μm (Al2O3) + Alloy Primer (Kuraray, CO) and TRAT. 2 - sandblasting with particles of oxide of silica with Cojet-Sand (3M/ESPE) + Silane (ESPE-SIL). The conditioned blocks of each group were luted with Panavia F (Kuraray, CO) to composite resin blocks of ClearfilTM AP-X (Kuraray, CO) under constant load of 750g for 10 minutes. Six experimental groups were constituted by sets formed by the alloy, cement and composite resin. The sets were split up in a mechanical lathe obtaining by block 4 samples with dimensions of 10x1x1mm and the adhesive surface with approximately 1mm2. The microtensile test was accomplished in an universal test machine (EMIC) with cell of load of 10kgf and crosshead speed of 1mm/min. Each group was represented by forty samples, however each group presented 10 means values of bond strength MPa (n=10), obtained from the mean of the individual values of the four samples of each cemented blocks. Means and standard deviation of bond strength (MPa) were: G1: 7.33 ± 1.93d; G2: 13.35 ± 2.18 c G3: 23.56 ± 6.5 b; G4:42.6 ± 5.84 a; G5: 26.17 ± 1.94 b; G6: 44.30 ± 2.3 a. The data of bond strength were analyzed by the analysis of variance test (ANOVA) and Tukey test, p<0.05. The results indicated that surface treatment 2 (Cojet) increased the bond strength between the resin cement and alloys. The smallest values of bond strength were obtained with gold alloy, independent of ....
243

Avaliação in vitro da biocompatibilidade de resinas acrílicas para base de próteses e materiais reembasadores resilientes /

Chaves, Carolina de Andrade Lima. January 2013 (has links)
Orientador: Ana Lúcia Machado / Co-orientador: Carlos Alberto de Souza Costa / Banca: Ana Carolina Pero Vizoto / Banca: João Neudenir Arioli Filho / Banca: Cláudia Helena Lovato da Silva / Banca: Renata Cunha Matheus Rodrigues Garcia / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de 3 resinas acrílicas (RA) para bases de prótese sendo duas polimerizadas por energia de microondas (Vipi Wave-VW e Nature Cryl-NC) e uma fotoativada (Eclipse-E); e a biocompatibilidade de materiais reembasadores resilientes (MRR), sendo 2 à base de silicone (Ufi Gel P e Sofreliner S), 2 à base de resina acrílica (Durabase Soft e Trusoft) e 2 condicionadores de tecidos (Softone e Coe Comfort) por meio de análises do metabolismo celular, da morfologia celular, do padrão de morte celular, da proliferação celular e da expressão do fator de crescimento TGFß 1, da integrina α5ß1 e de citocinas. A análise das RA foi realizada com células L929; para os MRR, as análises foram realizadas utilizando-se células L929, e/ou HaCaT e/ou RAW 264,7. Os resultados obtidos foram submetidos à análise estatística, realizada ao nível de significância de 5%. Todos os materiais quando testados com eluatos não apresentaram efeitos citotóxicos, e quando testados em contato direto (MTT e azul de alamar) alteraram significativamente a viabilidade celular, tendo sido os menores valores observados para o material NC quando comparado ao E. Para os materiais reembasadores o T, S e C. Maior taxa de necrose e apoptose foram observadas para os eluatos de todos os materiais quando avaliados no período de 24 horas; além disso, foi demonstrado que os materiais avaliados podem desencadear a expressão do TGFß 1, da integrina α5ß1 e de proteínas inflamatórias (fator de necrose tumoral - TNF-α, da citocina IL-1ß e de 5 quimiocinas: CCL2, CCL3, CCL5, CXCL2 e CXCL4). Sendo assim, de acordo com as limitações do presente estudo, pode-se concluir que a resina Nature Cryl resultou em menor viabilidade celular que a resina Eclipse e que os materiais Ufi Gel P e Sofreliner S apresentaram, em geral, melhor bicompatibilidade dentre os materiais reembasadores resilientes avaliados. / Abstract: The aim of this study was to evaluate the cytotoxicity of 3 denture base acrylic resins with different polymerization methods (Eclipse, Vipi Wave and Nature Cryl) and the biocompatibility of soft lining materials, 2 silicone-based (Ufi Gel P and Sofreliner S), 2 acrylic-based (Durabase Soft and Trusoft) and 2 tissue conditioners (Softone and Coe Comfort), by analysing cell metabolism, cell morphology, pattern of cell death, cell proliferation and expression of growth factor TGFß 1, integrin α5ß1 and cytokines. For the acrylic resins, analyses were made with L929 cells, while for the resilient lining materials, analyzes were performed using L929, and/or HaCaT and/or RAW 264.7 cells. Results were statistically analyzed, at a significance level of 5%. The 24 and 48-h eluates from all materials were not cytotoxic to the cells. For the direct contact tests (MTT and Alamar Blue), a significant effect on cell viability was found, with the lowest values observed for materials NC when compared with E and between the reliners Trusoft, Softone and Coe Comfort. For all materials, increased rate of necrosis and apoptosis were observed for the 24 hs eluates. It was also demonstrated that all materials tested can trigger the expression of TGFß 1, α5ß1 integrin and inflammatory proteins (tumor necrosis factor -TNF-α, cytokine IL-1ß and 5 chemokines- CCL2, CCL3, CCL5, CXCL2 and CXCL4). Thus, within the limitations of this study, it can be concluded that the denture base acrylic resin Nature Cryl resulted in lower cell viability compared to the Eclipse resin and that the materials Ufi Gel P and Sofreliner S showed better biocompatibility among the soft liner materials evaluated. / Doutor
244

Efeito do envelhecimento em baixa temperatura e desgaste no comportamento mecânico de uma cerâmica Y-TZP com duas espessuras diferentes indicada para restauração monolítica /

Prado, Rodrigo Diniz do. January 2016 (has links)
Orientador: Luiz Felipe Valandro / Coorientador: Marco Antonio Bottino / Banca: João Paulo Barros Machado / Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Resumo: O objetivo deste estudo foi avaliar o efeito do desgaste com broca diamantada, o envelhecimento (degradação em baixa temperatura) e espessura do material cerâmico no comportamento mecânico de uma cerâmica Y-TZP. Para este estudo, 240 espécimes foram fabricados em formato de disco, de acordo com a norma ISO 6872: 2008 para resistência à flexão biaxial de amostras de cerâmica (N = 120, com dimensões de 0,5 mm de espessura x 15 mm de diâmetro; N = 120 com a dimensão 1,0 milímetros de espessura x diâmetro 15 mm). Os espécimes foram divididos aleatoriamente em 8 grupos (n = 30), de acordo com três fatores em estudo: 'desgaste' em 2 níveis (com e sem desgaste com broca diamantada), o envelhecimento em 2 níveis (com e sem envelhecimento) e da espessura da cerâmica também em 2 níveis (0,5 a 1,0 mm). O desgaste foi realizado com uma broca diamantada montada em um motor de baixa rotação associado a um contra-ângulo multiplicador de velocidade (T2 REVOR R170, Sirona, Bensheim, Alemanha), sob constante irrigação de água. O envelhecimento foi simulado em uma autoclave à temperatura de 134 °C, durante um período de 20 horas, sob pressão de 2 bar. Após o desgaste e envelhecimento, análises de rugosidade e topográficas foram realizadas e análises de transformação de fase por difração de raios-X. Os dados coletados foram submetidos à análise de Weibull. O desgaste promoveu um aumento da rugosidade, enquanto que o envelhecimento em autoclave não afetou estatisticamente a rugosidade da superfíc... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The goals of this investigation were to evaluate the effects of grinding with diamond bur and aging (low temperature degradation) on the mechanical behavior of a fullcontour Y-TZP ceramic with two thicknesses. Y-TZP shaped-disc specimens (Zirlux FC, Ardent Dental) were manufactured with thickness of 0.5 mm and 1.0 mm (both with 15 mm in diameter). The specimens from every thickness were randomly assigned into 4 groups, according to two factors: 'grinding' on 2 levels (with and without grinding with diamond bur), aging in 2 levels (with and without aging). Grinding was performed with a diamond bur mounted in a slow speed rotation motor associated with a counter-angle speed multiplier hand-piece, under constant watercooling. Low temperature aging was performed in an autoclave at 134°C temperature, for a period of 20h, under 2 bar of pressure. After grinding and aging, roughness analyzes were performed on a surface roughness tester and 3D digital optical profilometer; topographic analysis were made in a scanning electron microscope; phase transformation analysis by X-ray diffraction. Biaxial flexural strength tests were performed in the universal testing machine. Specific statistical analyses were carried out (Weibull analysis for the strength data). Grinding promoted an increase in roughness, while aging in autoclave did not affect statistically the surface roughness. Also, grinding and aging lead to higher values of m-phase content, although, grinding lead to a decrease in the material susceptibility to a new phase transformations during aging (after aging, as-sintered condition resulted in higher m-phase content compared with ground). Independent on the zirconia's thickness, aging in autoclave and grinding led to an increase in characteristic strengths. Within the limits of this study, it was observed that: grinding and low ...(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
245

Estudo das microdeformações geradas ao redor de implantes de hexágono externo, sob a aplicação de cargas axiais e não axiais em pilares protéticos retos e angulados /

Rodrigues, Vinícius Anéas. January 2014 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Eduardo Bresciani / Banca: Rodrigo Tiossi / Resumo: O objetivo do estudo in vitro foi avaliar por meio da extensometria as microdeformações em prótese fixa de três elementos sobre implantes de hexágono externo, sob cargas axiais e não axiais e avaliar possíveis correlações com as fendas encontradas nas estruturas metálicas. Foram confeccionados dois blocos de poliuretano, receberam três implantes cada e foram divididos em dois grupos: reto e angulado em 17°. Para mensurar as microdeformações foram colados quatro extensômetros nas superfícies dos blocos, tangenciando cada um dos implantes. Foi utilizado intermediário do tipo microunit para todos os implantes, sendo que os implantes com inclinação de 17° receberam componentes para a correção da angulação. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Utilizou-se do dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf durante 10 segundos. Os dados obtidos foram submetidos ao ANOVA e Tukey (p< 0,05) e correlacionados com os valores de fenda através da correlação linear de Pearson. Os resultados mostraram que os valores para diferentes inclinações dos implantes foram estatisticamente significantes, sendo (p = 0,0022< 0,05) para os pontos axiais e (p = 0,0012< 0,05) para os pontos não axiais, sendo que o efeito ponto de aplicação de carga (p = 0,0001) obteve valores significantes apenas para os pontos não axiais; os resultados mostraram que não houve correlação entre as microdeformações e as fendas. Concluiu-se que as microdeformações são maiores para os implantes angulados de 17° e para os pontos mais distantes do parafuso de fixação das estruturas, nos pontos não axiais (3 e 5 mm), não foi encontrado correlação entre as fendas e os valores de microdeformação / Abstract: The aim of this in vitro study was to evaluate by strain gauge analysis, the micro-strain distribution around three elements implant supported partial prosthesis with external hexagon implants on axial and non-axial loading and to evaluate possible correlations with gaps found on the metal structures. Two polyurethane blocks were made, received three implants each and divided in two groups: straight and angled 17°. To measure the micro-strain, four strain gauges were bonded on the surface of the blocks tangentially to every implant. Microunit abutments were used for all implants, and the implants with an inclination of 17°, receiving abutment to correct angulations. Plastic copings were adapted to a standard pattern and cast. The metallic structure was screwed onto the abutments using a 10 Ncm torque. A static vertical load was applied 30kgf for 10 seconds with a load application device. The data were analyzed by ANOVA and Tukey's test (p< 0.05%) and related values gaps through the linear Pearson's correlation test. The results showed that the values for different implant inclinations were significant, (p = 0.0022) for axial points and (p = 0.0012) for non-axial points; whereas the point of application of load (p = 0.0001), obtained significant values only for non-axial points, the results showed no correlation between the micro-deformations and gaps. It was concluded that the micro-deformations are higher for the 17° angled implants and to the farthest points of the fastening screw of the structures in non-axial points (3 and 5 mm); there was no correlation found between the gaps and the values of microstrain / Mestre
246

Precisão de moldagens para implantes inclinados em maxila utilizando diferentes métodos de união de transfrentes e dois tipos de guias multifuncionais

Araújo, Raphael Ferreira de Souza Bezerra [UNESP] 05 March 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-05. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000867914.pdf: 1125966 bytes, checksum: 0e913723d2a96b546859d0335ca9badf (MD5) / Este estudo objetivou analisar a precisão de diferentes métodos de união de transferentes em moldagem sobre implantes utilizando guias multifuncionais em reabilitações orais de maxilas com implantes hexágono externo. Para as técnicas de moldagem com dois tipos de guia multifuncional (com e sem patalo) foi comparado diferentes métodos de união dos transferentes: transferentes unidos com metal e resina acrílica, transferentes unidos apenas com resina acrílica e transferentes sem união. Uma barra metálica passiva fabricada sobre o modelo mestre foi parafusado nos modelos de gesso no análogo A e realizado a mensuração 3 vezes da fenda presente nos análogos C e D. Posteriormente a barra é parafusado no análogo D e realizada a mensuração 3 vezes da fenda nos análogos A e B, utilizando um programa de análise de imagens (Leica QWin) que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa Leica (100X). Após verificação da distribuição e da homocedasticidade dos dados, métodos estatísticos (α=0,05) foram empregados para avaliar a influência das variáveis independentes. De maneira geral, os modelos geraram maiores desajustes marginais em relação ao modelo mestre, independentemente da técnica de união dos transferentes. Porém, só houve diferenças estatísticas quando comparado à técnica de moldagem OM=203,04µm (guia multifuncional com palato aberto e transferentes unidos com metal e resina acrílica) com às técnicas de moldagem PR=151,61µm (guia multifuncional com cobertura de palato e transferentes unidos com resina acrílica) e com o modelo Mestre (MM=142,78µm). Considerando as limitações desse estudo pode-se sugerir que a utilização da técnica de moldagem OM gera os modelos menos precisos. / This study analyze in vitro the accuracy of different union transfers methods in impressiom using multifunctional guides for prosthetic rehabilitation in a toothless jaw with external hexagon implants installed. For the impression techniques with two types of multifunctional guide (palate coverage and open palate) it was compared different methods of union of the square transfers: metal splinted transfers, acrylic resin splinted transfers and without splinted transfers. A metal structure fabricated on the master model with passive fit was screwed in the models obtained, on A analogue while measurements were made 3 times on analogs C and D and when screwed into analog D measurements were made 3 times in analogues A and B, by a image analysis software (Leica QWin) that received the images from a video camera attached to a Leica magnifier (100X). After verification of distribution and homoscedasticity data, statistical methods (α = 0.05) were used to assess the influence of the independent variables. In general, larger models generated fringe displacement in relation to the master model, irrespective of splint techniques. But only exist statistical differences when compared the impression technique OM = 203,04µm (multifunctional guide with open palate and transfers splinted with metal and acrylic resin) with impression technique PR = 151,61µm (multifunctional guide with coverage palate and transfers splinted with resin acrylic) and the master model (MM = 142,78µm). Considering the limitations of this study may suggest that the use of OM molding technique generates less accurate models.
247

Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas: análise de elemento finito não linear com modelo tridimensional

Geremia, Tomás January 2014 (has links)
Made available in DSpace on 2015-04-30T14:06:27Z (GMT). No. of bitstreams: 1 000467680-Texto+Completo-0.pdf: 13016515 bytes, checksum: e3ef505603c7d5be9a1581e535fd60e2 (MD5) Previous issue date: 2014 / The aim of this study was to evaluate the influence of the number of implants and the distal tilting of posterior implants (27 degrees) on the resulting tensions in periimplant bone, abutment screw and prosthetic screw of mandibular full-arch fixed implant supported prosthesis, using a nonlinear finite element analysis. Six virtual models were created, simulating a mandibular full-arch prosthesis with a metallic framework: models with five parallel implants (5R) and with tilted posterior implants (5I); models with four parallel implants (4R) and tilted posterior ones (4I); and models with three parallel implants (3R) and with tilted posterior implants (3I). The Von Mises tensions were analyzed, on a qualitative aspect, on the three regions of interest. The results showed that tilting the posterior implants resulted in higher tensions on the periimplant bone region. Also, the implant placed adjacent to the loading area presented the higher stress magnitudes on the three regions of interest, during all the simulations. Within the limitations of this study, it's possible to conclude that tilting the posterior implants without distalizing the implants platforms, can represent higher Von Mises tensions on the cortical periimplant bone. Still, that the use of three implants supporting a mandibular full-arch prosthesis generated higher stress values on the analyzed regions, when compared to the models simulating four and five implants. / O objetivo do presente trabalho foi avaliar em reabilitações totais fixas implantossuportadas, através de uma Metodologia de Elementos Finitos não linear, a influência do número e da inclinação dos implantes posteriores em 27 graus para distal nas tensões em osso periimplantar cortical, parafuso do pilar protético e parafuso protético. Seis modelos virtuais foram gerados simulando uma prótese total fixa mandibular, com infraestrutura metálica: modelos com 5 implantes, paralelos entre si (5R) e com dois posteriores inclinados (5I); modelos com 4 implantes, paralelos entre si (4R) e com dois posteriores inclinados (4I); modelos com 3 implantes, paralelos entre si (3R) e com dois posteriores inclinados (3I). Uma força de 100 N foi simulada em região de primeiro molar, no cantilever protético. As tensões Von Mises resultantes foram analisadas de forma qualitativa nas três regiões de interesse. Os resultados mostraram que a utilização de implantes posteriores inclinados resultaram em maiores tensões na região periimplantar. Ainda, que o implante adjacente à carga apresentou os maiores valores de tensão nas três regiões avaliadas em todas as simulações. Dentro das limitações deste trabalho, pode-se concluir que a inclinação de implantes posteriores, sem a distalização das plataformas dos mesmos, mostra-se desfavorável no que diz respeito à incidência de tensões no osso periimplantar cortical. Além disso, a utilização de três implantes suportando uma prótese total fixa mandibular, apresentou maiores valores de tensão se comparado as situações com quatro e cinco implantes.
248

A influência de implantes dentários em imagens de radiografia periapical, panorâmica e tomografia computadorizada de feixe cônico

Felix, Rafael Perdomo January 2015 (has links)
Made available in DSpace on 2015-05-22T12:38:47Z (GMT). No. of bitstreams: 1 000469176-Texto+Completo-0.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5) Previous issue date: 2015 / Imaging exams performed in areas with the presence of metallic materials such as dental implants can decrease the accuracy of the exams due to metallic artifacts production generated in the peri-implant region. A sample of 21 dental implants placed in 10 patients with Branemark protocol prostheses was evaluated in the periimplant area in image exams of the post-surgery control using periapical radiography (paralleling technique), panoramic radiography and cone-beam computed tomography (CBCT). The radiographic density of different areas bounded near the dental implants were calculated and compared considering their locations and the imaging exams using the software ImageJ. Regarding the different imaging exams, the CBCT showed significant differences between the measured areas (p<0. 001), while in periapical (p=0. 430) and panoramic (p=0. 149) radiographs did not occur significant difference between the gray mean values in these areas. Comparing the areas in the three exams it was observed larger values next to the implants in all exams: CBCT (126. 20 and 127. 44) panoramic radiography (106. 51 and 106. 09) and periapical radiography (120. 32). The more distant areas and the areas closest to neighboring implants had significant different values in the two reconstructed images of CBCT when compared to the panoramic and periapical radiographs. The interference of dental implants in acquiring radiographic and tomographic exams was confirmed by altered radiographic density mean values in the peri-implant area. Comparing the three exams it was noticed that the CBCT image showed the most significant interference of the dental implants. / Os exames por imagem realizados em áreas que apresentam materiais metálicos, como implantes dentários, podem ter sua qualidade prejudicada devido à produção de artefatos metálicos gerados na região peri-implantar. Uma amostra de 21 implantes dentários, em 10 pacientes com próteses do tipo protocolo Branemark, foi avaliada com o objetivo de comparar as densidades radiográficas na região periimplantar em exames de imagens de controle pós-operatório com radiografia periapical (técnica do paralelismo), radiografia panorâmica e tomografia computadorizada de feixe cônico. Os valores médios de densidade em áreas delimitadas próximas aos implantes dentários foram calculados e comparados, de acordo com suas localizações, e entre os exames de imagens utilizando o programa ImageJ. Os exames de Tomografia Computadorizada de Feixe Cônico (TCFC) apresentaram diferenças significativas entre as áreas medidas (p<0,001), enquanto que nas radiografias periapical (p=0,430) e panorâmica (p=0,149) não houve diferença significativa entre os valores médios de densidade nas mesmas áreas. Na comparação entre as áreas dos três exames, observou-se valores maiores naquelas próximas aos implantes em todos os exames: TCFC (127,88 e 120,71), panorâmica (106,51 e 106,09) e periapical (120,32). As áreas mais distantes e próximas aos implantes vizinhos mostraram valores significativamente diferentes nos dois cortes da TCFC quando comparados aos exames periapical e panorâmico. Sendo assim, foi possível confirmar a interferência dos implantes dentários na obtenção dos exames radiográficos e tomográficos, pela alteração dos valores médios de densidade radiográfica na região peri-implantar. Na comparação entre os três exames de imagem investigados, verificou-se que as imagens de TCFC sofreram a maior interferência dos implantes dentários, quando comparadas com as imagens radiográficas.
249

Efeito da lubrificação sobre a pré-carga e o torque de remoção de parafusos odontológicos de conexão submetidos a ciclos de aperto e desaperto

Kunz, Tiago January 2015 (has links)
Made available in DSpace on 2016-02-12T01:05:11Z (GMT). No. of bitstreams: 1 000477181-Texto+Completo-0.pdf: 2813092 bytes, checksum: 4a31e9fa6f6b00754e7f702733f5c592 (MD5) Previous issue date: 2015 / Screw loosening is often a complication reported in prosthetic implants. The torque develops a compressive clamping force between parts called preload, which holds the components together and the reducing of friction between the surfaces has been shown to increase its value. Dry lubricants, also called coatings have been used and the results are satisfactory, but the use of liquid lubricants is still little explored, which is the aim of this study. For this, 14 titanium screws and 14 screws with (Diamond-Like Carbon) DLC coating were randomly assigned to four groups (Titanium; DLC, Titanium with oil, and DLC with oil) and subjected to five cycles of tightening and loosening. The screws of groups Titanium with oil and DLC with oil were lubricated with castor oil. The preload was measured by a preload gauge cell, especially developed for the study. The results of preloads and average removal torques for torques of 20 and 32Ncm at 2 different times were analyzed: after the first grip and after five consecutive grips. At the end of the analysis, the thread pitches were measured to rule out plastic deformation. The Group DLC had higher pre-load values at all time points, but it was only significant after the sequence grips with 32 Ncm, and in the absence of oil. It was concluded, therefore, that the castor oil lubrication was not able to significantly increase the preload values or removal torque. / O afrouxamento do parafuso é uma complicação frequentemente reportada em próteses sobre implantes. O torque desenvolve uma força compressiva de aperto entre as partes chamada pré-carga, que mantém os componentes unidos, e a redução do atrito entre as superfícies tem demonstrado aumentar o seu valor. Lubrificantes secos, também chamados de recobrimentos, têm sido utilizados e os resultados são satisfatórios, contudo o emprego de lubrificantes líquidos ainda é pouco explorado, sendo o objetivo deste estudo. Para isso, 14 parafusos de titânio e 14 parafusos com recobrimento de Diamond-Like Carbon (DLC) foram aleatoriamente alocados em quatro grupos (Titânio; DLC; Titânio com Óleo; e DLC com Óleo) e submetidos a cinco ciclos de aperto e desaperto. Os parafusos dos grupos Titânio com Óleo e DLC com Óleo foram lubrificados com óleo de mamona.A pré-carga foi mensurada por meio de uma célula aferidora de pré-carga, desenvolvida especialmente para o estudo. Foram analisados os resultados das pré-cargas e torques de remoção médios para os torques de 20 e 32 Ncm em dois momentos distintos: após o primeiro aperto e depois de cinco apertos consecutivos. Ao fim das análises, os passos de roscas foram mensurados para descartar deformações plásticas. O Grupo DLC apresentou maiores valores de pré-carga em todos os momentos de avaliação, contudo ele só foi significativo após a sequência de apertos com 32 Ncm, e na ausência do óleo. Concluiu-se, portanto, que a lubrificação com óleo de mamona não foi capaz de aumentar significativamente os valores da pré-carga ou do torque de remoção.
250

Influência do torque e da ciclagem mecânica na manutenção da pré-carga e resistência à fratura de parafusos de retenção em diferentes junções parafusadas /

Silva, Ebele Adaobi. January 2016 (has links)
Orientador: Wirley Gonçalves Assunção / Coorientadora: Maria Cristina Rosifini Alves Resende / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Juliana Aparecida Delben / Resumo: Sendo o afrouxamento e fratura dos parafusos de retenção as principais complicações em próteses implantossuportadas, este estudo teve como objetivo avaliar a manutenção do torque remanescente e ocorrência de fraturas em parafusos de retenção de pilares UCLA, para implantes de conexão hexagonal externa e cone Morse, em função do torque aplicado (recomendado pelo fabricante, torque obtido através de aperto manual e sem torque), submetidos à ciclagem mecânica. Sequencialmente, investigou-se a resistência à fratura desses parafusos por meio do teste de compressão em uma máquina de ensaio universal. Foram utilizados 36 implantes embutidos em poliuretano com uma inclinação de 30°, divididos em 6 grupos em função do tipo de conexão e do torque aplicado. De forma randomizada, os espécimes pertencentes ao grupo sem torque foram submetidos a ciclagem mecânica e os dos grupos torque recomendado pelo fabricante e torque manual foram submetidos a aplicação do torque e mensuração da pré-carga remanescente, antes (3 minutos após o aperto) e após a ciclagem mecânica (após 1x106 de ciclos). Ao fim da ciclagem, os parafusos foram submetidos ao teste de resistência a fratura por meio do ensaio de compressão, no qual foi aplicado uma carga de 5000N sob a velocidade de 0,5mm/min. Os resultados mostraram que em uma análise geral, o torque remanesce foi significantemente menor (p<0,05) após a ciclagem mecânica. Ao se comparar os dois tipos de conexão, não houve diferença em relação o torque remanes ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Being loosening and fracture of retention screws the main complications in implant-supported prostheses, this study aimed to evaluate the preload maintenance and the occurrence of fractures at retention screws of UCLA-type abutment for implants with external hexagon connection and Morse Taper, due to the applied torque (recommended by the manufacturer, torque obtained by manual tightening and no torque), submitted to mechanical cycling. Sequentially, the fracture resistance of these screws was investigated by the compression test on a universal testing machine. Thirty-six implants embedded in polyurethane with an inclination of 30° were used and divided into 6 groups according to the type of connection and the applied torque. Randomly, the specimens belonging to the group without torque underwent mechanical cycling and groups of recommended by the manufacturer torque and manual torque underwent torque application and measurement of the remaining preload, before (three minutes after tightening) and after mechanical cycling (after 1x106 cycles). After cycling, the screws were submitted to the fracture resistance test by the compression test, which was applied a 5000N load under 0,5 mm/min speed. The results showed that in a general analysis, preload maintenance was significantly lower (p <0,05) after mechanical cycling. When comparing the two types of connection, there was no difference regarding to preload maintenance (p>0,05). For different types of torque, it was observed ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.3617 seconds