• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 710
  • 37
  • 37
  • 37
  • 37
  • 28
  • 9
  • 8
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 728
  • 728
  • 357
  • 269
  • 232
  • 185
  • 141
  • 141
  • 123
  • 118
  • 107
  • 105
  • 89
  • 80
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Infiltração bacteriana nas interfaces entre implantes e pilares: efeito do desenho das conexões protéticas /

Lima, Elen Guerra de. January 2014 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Renata Faria / Banca: Marco Antonio Bottino / Resumo: O objetivo do estudo foi avaliar a microinfiltração bacteriana in vitro na interface entre o pilar e o implante, comparando-se Hexágono Externo (HE), Hexágono Interno (HI), Conexão Cônica (CC), sendo esta última de 3 tipos diferentes de desenho dos componentes protéticos. Para tal, 150 conjuntos (pilar/implante) foram utilizados, divididos em cinco grupos (n = 30). G1 - pilares HE; G2 - pilares HI; G3 - pilares CC do tipo sólido; G4 - pilares CC do tipo indexado; G5 - pilares CC do tipo linha zero. Para a avaliação, suspensão das bactérias Escherichia coli (ATCC 25922) e Streptococcus sanguinis (ATCC 10557) foram inoculadas na porção apical do parafuso do pilar, sob condições estéreis. Os pilares foram fixados aos implantes e torqueados segundo recomendações do fabricante, e imersos em caldo BHI estéril durante 14 dias. Ao final do período, os conjuntos foram separados, o conteúdo interno foi sonicado, diluído, semeado e levado a estufa bacteriológica (37 ºC por 48 horas) para verificação da viabilidade e contagem das bactérias. As amostras que não continham E. coli e S. sanguinis viáveis, foram descartadas do estudo. A morfologia bacteriana foi ainda observada em microscopia eletrônica de varredura (MEV). Os resultados, em % e unidades formadoras de colônias (UFCs) foram analisados por teste estatístico ANOVA 1 fator. Não houve diferença estatística entre G2 (9,09%), G3 (21,74%), G4 (22,73%) e G5 (11,11%). Analisando-se separadamente os grupos não-turvados com E. Coli (p = 0,126) e S. Sanguinis (p = 0,962) e os grupos turvados com E. coli e S. sanguinis (p = 0,655.) com Anova 1- fator (p < 0,05), não houve diferenças significantes na contagem de UFC entre os tipos de conexões / Abstract: The aim of this study was to evaluate the in vitro bacterial microleakage at the interface between the abutment and the implant, comparing 3 types of prosthetic connections: External Hexagon (EH), Internal Hexagon (IH), Taper Connection (TC), the latter of 3 different types of the design of the abutments. For this, it was utilized 150 sets (abutment / implant), that were divided into 5 groups (n = 30). G1 (Control) - EH abutments; G2 - IH abutments; G3 - TC solid abutments; G4 - TC indexed abutments; G5 - TC zero line abutments. For this evaluation, suspension of the bacterial Escherichia coli (ATCC 25922) e Streptococcus sanguinis (ATCC 10557) were inoculated in the apical portion of the abutment screw, under sterile conditions. The abutments were fixed to the implants and torqued according to manufacturer's recommendations, and immersed in sterile BHI broth for 14 days. At the end of the period all sets were separated, the inner contents was be sonicated, diluted, seeded and taken to a bacteriological incubator (37 °C for 24 hours) to check the viability of the bacteria. The samples that did not contain viable E. coli e S. sanguinis were discarded from the study. The staining and bacterial morphology were observed in optical microscope and scanning electron microscopy (SEM). Results of colony forming units (CFUs) were analyzed by ANOVA 1 factor. There were no differences between the percentage of bacterial infiltration for IH (9.09%), CS (21.74%), CI (22.73%) e C0 (11.11%). Analising separetly the groups non-infritated with E. coli (p = 0,126) and S. Sanguinis (p = 0,962) and the groups infiltrated with E. coli and S. sanguinis (p = 0,655.) (p < 0,05), there no was statistical difference in the count of CFU/ml between the connections type / Mestre
272

Comportamento mecânico de sistemas prótese/implante em região dos elementos finitos e interferometria holográfica /

Corrêa, Cássia Bellotto. January 2013 (has links)
Orientador: Luís Geraldo Vaz / Coorientador: Rogério Margomar / Coorientador: Pedro Yoshito Noritomi / Banca: Carlos Alberto dos Santos Cruz / Banca: Valfrido Antonio Pereira Filho / Banca: Mário Augusto Pires Vaz / Banca: Rodrigo Alvarenga Rezende / Resumo: A proposta deste estudo foi analisar, por meio do método de elementos finitos (MEF), o comportamento mecânico das estruturas envolvidas em uma reabilitação implanto suportada de 4 elementos na região anterior de maxila, utilizando apenas 2 implantes, variando os posicionamentos dos implantes e o tipo de conexão protética (hexágono externo, hexágono interno e cone-Morse) e ainda validar metodologia de análise computacional por meio da interferometria holográfica, uma técnica experimental. Modelos tridimensionais baseados em um banco de tomografias computadorizadas foram criados para todas as situações estudadas (Implantes nos Incisivos Laterais - IL; Implantes nos Incisivos Centrais - IC e Implante no Incisivo Central e Incisivo Lateral - ILIC). Uma carga equivalente à 150N foi aplicada a 45° na região de cíngulo de cada elemento dentário. Para a validação da metodologia de elementos finitos por meio da interferometria holográfica, criou-se um modelo prototipado com as mesmas situações estudadas e comparou-se os deslocamentos direcionais resultantes da aplicação de 3 intensidades de força. Como resultado foi observado: o menor deslocamento da estrutura protética e maior deslocamento na estrutura óssea no grupo IC. No tecido ósseo, a tensão de von Misses localiza-se predominantemente na região cortical. O valor máximo de tensão de von Misses foi observado no implante vizinho ao cantilever no grupo ILIC. Na conexão cone Morse, o parafuso protético mostrou metade da tensão de von Misses em relação a conexão hexágono interno e hexágono externo. Comparando-se os deslocamentos direcionais nas duas metodologias, verificou-se que havia uma correlação positiva entre os resultados, porém os valores obtidos experimentalmente eram superiores aos do modelo computacional. Pode-se concluir... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to analyze, by finite element method (FEM), the mechanical behavior of structures involved in an implant supported rehabilitation of 4 elements in the anterior maxilla, using only 2 implants, varying the placements of the implants and prosthetic connection types (external hexagon, internal hexagon and Morse taper) Moreover to validate the methodology of MEF by holographic interferometry, an experimental technique. Three-dimensional models based on a database CT scans were created for all situations studied (Implants in Lateral Incisors - IL; Implants in Central Incisors IC and Implant in Central e Lateral Incisor - ILIC). An equivalent load of150N was applied at 45° in the cingulum of each tooth. To validate the finite element method by Holographic Interferometry, a prototyped model was created with the same situations studied and compared the directional displacements, resulting from the application of the 3 intensities of force. As results it was observed: the lowest prosthetic displacement structure and greater displacement in the bone structure in the IC group. In bone tissue, the von Mises stress is located predominantly in the cortical region. The maximum value of von Mises stress was observed in the implant neighboring to cantilever in the group ILIC. In Morse taper connection, the prosthetic screw showed half the von Misses stress in relation to internal and external hexagon connection. Comparing the directional displacement in both methodologies, an positive correlation between the results was found, although the experimentally values obtained were higher than those of the computational model. It can be concluded that the placement of implants and prosthetic connection type have influence in the intensity and distribution of stress/strain on the implant-supported rehabilitation of anterior... (Complete abstract click electronic access below) / Doutor
273

Avaliação da precisão dos modelos de gesso obtidos por diferentes técnicas de moldagem para próteses múltiplas implanto suportadas

Becker, Anne Buss January 2014 (has links)
Made available in DSpace on 2014-07-19T02:02:56Z (GMT). No. of bitstreams: 1 000459308-Texto+Completo-0.pdf: 2403047 bytes, checksum: 9f617311a86d53fd907e33dfdebe0f05 (MD5) Previous issue date: 2014 / The aim of this study was to evaluate the accuracy of implants master casts obtained by pick- up techniques with an open custom tray using squared impression copings, using several union transfers on two, in vitro, experimental models. First, the dimensional accuracy of implants master cast was evaluated, and two impression techniques: G1- squared impression copings (S) and G2- splinted squared copings, using dental floss and acrylic resin for implant-supported prostheses. An aluminum block with 2 implant-abutment analogs were fabricated (one implant was made at right angle to the top surface “A” and the other was angulated 65 degrees sideway “B” and a frameworks in type NiCr was used. Impression was performed using acrylic resin tray and polyether impression material. Specimens were divided in two experimental groups: squared impression copings (S) and splinted squared copings. Five casts were made per group, in total of 10 casts. A software was used in order to analyze and to record the vertical gap between reference framework and analogs in duplicate casts, connected to a stereomicroscope. Results showed statistical differences between group 1 and 2, with lower levels of gaps in the splinted squared copings, using dental floss and acrylic resin compared to the squared impression copings (P=. 021). On the implant evaluation, higher values were obtained for the implant angulated 65 degrees with squared impression copings technique (P=. 013).A aluminum block with 2 parallel implant-abutment analogs were fabricated, in order to evaluated the accuracy of implants master cast, poured with die stone (GC Fujirock EP; GC Europe, Leuven, Belgium and Dentona AG, Europe, Dortmund, Germany) using 3 different impression techniques and two differents commercial trademarks of stone, compared to a control group. Polyether impression material was used for all impression with acrylic resin tray. Seven groups were formed: G1 – control group; G2a – Squared impression copings, poured with a die stone GC Fujirock EP; G2b – Squared impression copings, poured with a die stone Zero Stone G3a – Splinted squared copings using dental floss and acrylic resin poured with a die stone GC Fujirock EP; G3b- Splinted squared copings using dental floss and acrylic resin - poured with a die stone Zero Stone; G4a - Splinted squared copings using dental floss and bisacrilica resin - poured with a die stone GC Fujirock EP; G4b - Splinted squared copings using dental floss and bisacrilica resin poured with a die stone Zero Stone. The distances between the analogs of each specimen were measured, using a software, connected to the stereomicroscope. Results presented statistical differences between the distances of G1 and G2a (p=0. 010), G2b (p=0. 015), G4b (p=0. 007). No statistical differences were found between G1 and G3a (p=0. 178), G3b (p=0. 288), G4a (p=0. 531). Splinted squared copings poured with a die stone GC Fujirock EP produced cast most similar to the control Group. In conclusion, the accuracy of the SS impression technique was superior to squared impression copings (S), for implants presenting different angulation; the inaccuracy seen with the squared impression copings (S) method seemed to correlate with the nonparallel (< 65°) abutment relationship and the apparent deformation of the impression material. / O objetivo deste estudo foi avaliar a precisão dos modelos de gesso sobre implantes obtidos por meio da técnica de moldagem de arrasto, na qual utiliza transferentes quadrados, utilizando diferentes materiais para união dos transferentes por meio de dois modelos experimentais in vitro. Inicialmente avaliou-se a precisão dos modelos de gesso obtidos por meio de duas diferentes técnicas de moldagem: Grupo 1 – Moldagem de arrasto sem união dos transferentes e Grupo 2 – Moldagem de arrasto com união dos transferentes em resina acrílica autopolimerizavel para próteses implanto suportadas. Um bloco de alumínio com 2 análogos do implante minipilar 4. 1 (Neodent SA Curitiba, Parana, Brasil) foi fabricado, sendo um analogo posicionado em angulo reto com o topo da superficie e outro inclinado a 65 graus lateralmente. Uma infraestrutura em liga NiCr, foi fabricada. As moldagens foram realizadas com moldeira individual em resina acrilica e o material utilizado foi o polieter. Dois grupos foram formados: Grupo 1 – sem união e Grupo 2 – com união em resina acrilica. Foram obtidos 5 modelos de gesso por grupo totalizando 10 modelos. A distância entre a infraestrutura e os analogos foi mensurada (gap vertical) por meio do programa (AxionVision 4. 8. 1, Zeiss; Carl Zeiss, Jena, Germany) acoplado a lupa estereomicroscopia. Os resultados mostraram diferenças significantes entre os grupos 1 e 2, com menores valores de gap para o grupo com união em resina acrilica (p=0,021). Na avaliação por implante, maiores valores foram obtidos para implantes inclinados (65 graus lateralmente) pela tecnica sem união (p=0,013).Posteriormente, um bloco de alumínio com dois implantes paralelos foi fabricado e foi investigado a precisão dos modelos de gesso obtidos por meio de três diferentes técnicas de moldagem e duas diferentes marcas comercias de gesso tipo IV (A - Fujirock EP; GC Europa, Leuven, Belgica e B - Zero Stone; Dentona AG, Europa, Dortmund, Alemanha), comparados com um grupo controle (bloco de alumínio com dois análogos do implantes minipilar 4. 1 paralelos entre si). O material utilizado para as moldagens foi o poliéter. Sete grupos foram formados: G1 – grupo controle, G2a – sem união e gesso Fujirock, G2b – sem união e gesso Zero Stone, G3a – união com resina acrilica e gesso Fujirock, G3b – união com resina acrilica e gesso Zero Stone, G4a - união com resina bisacrilica e gesso Fujirock, G4b - união com resina bisacrilica e gesso Zero Stone. Foram avaliadas as distancias entre os implantes por meio do programa (AxionVision 4. 8. 1, Zeiss; Carl Zeiss, Jena, Germany) acoplado a lupa estereomicroscopia. Os resultados mostraram diferenças significante entre as distancias do G1 - grupo controle e os grupos: G2a - sem união e gesso Fujirock (p=0. 010), G2b- sem união e gesso Zero Stone (p=0. 015) e G4b - união com resina bisacrilica e gesso Zero Stone. (p=0. 007).Não houve diferenças significantes entre o G1 - grupo controle e os grupos G3a - união com resina acrilica e gesso Fujirock (p=0. 178), G3b- união com resina acrilica e gesso Zero Stone (p=0. 288), G4a - união com resina bisacrilica e gesso Fujirock (p=0. 531). Conclui-se que os grupos sem união dos componentes produziram maiores distorções quando comparadas ao grupo controle. Em conclusão, a moldagem sem união dos transferentes, apresentou maiores distorções. A desadaptação entre infraestrutura e análogo com a técnica sem união parece estar correlacionada com a ausência de paralelismo dos implantes dentários.
274

Tradução e validação de um questionário sobre aspectos emocionais e sociais relacionados à alimentação de usuários de próteses dentárias

Valdez, Eduardo José January 2015 (has links)
Made available in DSpace on 2015-04-30T14:05:37Z (GMT). No. of bitstreams: 1 000466320-Texto+Completo-0.pdf: 1945321 bytes, checksum: a912d2ef37daa2e76c0ca2c193b5362e (MD5) Previous issue date: 2015 / Introduction: To assess the impact of prosthetic rehabilitation and formulate a suitable dietary advice is necessary to obtain detailed information about the experience of eating in patients who use dentures. The objective of this study was to translate to Brazilian Portuguese, culturally adapt and validate a questionnaire that reflects the concerns of denture wearers on aspects of their wellbeing related to food. Methods: The instrument was translated, back-translated, evaluated by a committee of experts, and then went through a process of cultural adaptation, following the World Health Organization standards for test translation. To test the Reliability of the instrument Cronbach's alpha coefficient was applied to assess the internal consistency. The Intraclass correlation test (ICC) and the difference between the means of the VAS scores for each domain were applied to evaluate the concordance of responses in two different moments. Results: The instrument was applied to 24 dental wearers, twice with 2 to 15 days of interval. The internal consistency was considered acceptable (0. 77) only in the domain 'enjoyment of food/eating' and good for the other domains, ranging between 77 and 95%. The instrument showed good reproducibility, with ICC values between 0. 77 and 0. 95.Conclusion: A Brazilian Portuguese version of the ESIRE questionnaire was adapted culturally. Internal consistency and reliability of the data allow the instrument to be used to obtain additional information related to the denture users’ experiences with eating in further research or in dental offices. / Introdução: Para avaliar o impacto da reabilitação protética e formular um aconselhamento dietético adequado é necessário obter informações detalhadas sobre as experiências relacionadas à alimentação de pacientes que usam próteses dentárias. O objetivo deste estudo foi traduzir para o português brasileiro, adaptar culturalmente e validar um questionário que reflete as preocupações dos usuários de próteses dentárias relacionadas ao bem estar com a alimentação.Métodos: o instrumento foi traduzido, retrotraduzido e avaliado por um comitê de especialistas. Posteriormente passou por processo de adaptação cultural, conforme o protocolo de tradução de instrumentos da Organização Mundial de Saúde, e validado. Para testar a confiabilidade, o coeficiente Alpha de Cronbach foi aplicado, avaliando a consistência interna do instrumento. O Coeficiente da Correlação Intraclasse (CCI) e a diferença entre escores nos diferentes domínios foram aplicados para avaliar a reprodutibilidade do questionário em dois momentos distintos. Resultados: O instrumento foi aplicado em 24 indivíduos portadores de prótese dentária em dois momentos com intervalo de 2 a 15 dias. A consistência interna foi considerada aceitável (0,77) somente no domínio ‘satisfação com a alimentação’ e boa para os demais domínios, variando entre 77 e 95%. O instrumento mostrou-se de boa reprodutibilidade, com valores do CCI, entre 0,77 e 0,95.Conclusão: Uma versão em português do questionário ESIRE foi adaptada. Os dados de consistência interna, reprodutibilidade e validação permitem que o instrumento seja utilizado para obtenção de informações adicionais relacionadas a alimentação de usuários de próteses dentárias em novas pesquisas ou em consultórios odontológicos.
275

Degradação de condicionadores teciduais em próteses totais: estudo in situ

Elsemann, Rogério Brasiliense January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:03Z (GMT). No. of bitstreams: 2 000389582-0.pdf: 4751378 bytes, checksum: 96556d08ded117c5d6139618402559ab (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This in situ study evaluated the degradation of tissue conditioners as a function of the timespan of clinical use measuring the variables Shore A hardness and quantity of plasticizer phthalate. The three tissue conditioners evaluated were Coe-Comfort, Dura Conditioner, and Softone. The materials were prepared according to each manufacturer’s instructions and inserted into grooves (5x15x2 mm) made in the palatal inner surface of maxillary complete dentures of nine patients at the FO-PUCRS Complete Dentures Clinics. These patients were selected following the inclusion and exclusion criteria and used their dentures during the evaluation period. Data collection was performed at baseline and 3, 7, and 14 days after the insertion of the materials into the dentures grooves. Shore A hardness was recorded by using an analogical Shore A durometer. The quantity of plasticizer phthalate was measured by means of infrared spectroscopy. One specimen of each material was randomly chosen at each test-time for observation of surface topography in scanning electron microscope. Data were analyzed by ANOVA for repeated measures followed by Tukey test, and by simple linear regression, at the 5% significance level.All tested tissue conditioners showed decrease of quantity of phthalate and increase of hardness over time. The overall degradation was similar for all tissue conditioners but the pattern of phthalate lixiviation and of hardness alteration was material-specific. The largest changes of phthalate concentration and Shore A hardness of the tested tissue conditioners occurred in the first three days of clinical use. Comparing baseline and day 3 data, Coe-Comfort showed 25% decrease of initial phthalate concentration, which was statistically different from the other materials with reduction of 50%. No significant alteration of phthalate concentration was detected between days 3 and 7. The quantity of plasticizer in the material is inversely related to the hardness of the tissue conditioner. / Este estudo in situ avaliou a degradação de condicionadores de tecido em função do tempo de uso clínico, mensurando a dureza Shore A e a quantidade do agente plastificante ftalato. Três materiais condicionadores de tecido foram avaliados: Coe-Comfort, Dura Conditioner e Softone. Os três materiais foram manipulados de acordo com as instruções dos fabricantes e inseridos em canaletas (5x15x2 mm) preparadas na região palatal da superfície interna de próteses totais superiores de nove pacientes da Clínica de Prótese Total da FO-PUCRS selecionados de acordo com os critérios de inclusão e exclusão, que permaneceram utilizando suas próteses durante o período de avaliação. As análises foram realizadas no baseline, no terceiro, sétimo e décimo-quarto dias, após a inserção dos condicionadores em boca. As mensurações da dureza foram registradas por meio de um aparelho durômetro Shore A analógico e a quantidade de plastificante foi mensurada por espectrofotometria de infravermelho. Foram selecionadas aleatoriamente espécimes dos três condicionadores de cada intervalo de tempo para análise em microscópio eletrônico de varredura.Os dados foram analisados por ANOVA utilizando o delineamento em medidas repetidas seguida pelo Teste de Comparações Múltiplas de Tukey e por regressão linear simples, ao nível de significância de 5%. Todos os condicionadores de tecido testados apresentaram redução da quantidade de plastificante ftalato e aumento da dureza ao longo do tempo do estudo. O comportamento geral de degradação dos condicionadores de tecido testados foi similar mas o padrão de lixiviação de ftalato e de aumento de dureza foi específico para cada material. As maiores alterações de concentração de ftalato e de dureza Shore A dos condicionadores de tecido estudados ocorreram nos primeiros três dias de uso clínico. Entre o baseline e o dia 3 o Coe- Comfort apresentou redução de aproximadamente 25% da concentração inicial de ftalato, sendo estatisticamente diferente dos demais materiais que apresentaram perda de 50%. Não houve alteração significativa da quantidade de ftalato entre os dias 3 e 7. A quantidade de plastificante no material está inversamente relacionada com a dureza dos condicionadores de tecido.
276

Influência do alívio, tipo de cimento e anatomia radicular na remoção de núcleos metálicos com ultrassom sob diferentes condições

Couto, Álvaro Heitor Cruz January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:04Z (GMT). No. of bitstreams: 2 000425873-0.pdf: 468713 bytes, checksum: 14f7045473cc5920546f071ff0719288 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the removal of metallic cores using ultrasound in the variables: relief, type of cement (zinc phosphate and glass ionomer) and root canal anatomy (circular and oval). For this, 80 healthy single-root human teeth were select (upper canines and lower incisors and lower premolars). The teeth had their crowns removed and the root canals received endodontic treatment and post space was prepared for receiving cores in Ni-Cr. The teeth were divided into eight groups (n = 10): Group 1: circular root canal with zinc phosphate, Group 2: circular root canal with zinc phosphate and group 3: oval root canal with glass ionomer and Group 4: oval root canal with glass ionomer, Group 5: oval root canal with zinc phosphate and Group 6: oval root canal with zinc phosphate, Group 7: circular root canal with glass ionomer, Group 8: circular root canal with glass ionomer. Groups 1, 3, 5, 7 received a 2mm relief in the region of cementation, around the root channel between the metallic core and cervical root portion of the tooth. After the cementation, the root portion was embedded in PVC tubes with self-cured acrylic resin. After this, the coronal portions were submitted to ultrasound and the time (s) for removal was measured. Oval root canals required more time for removal of metallic cores. Relief made around the root canal decreases the time required to perform the removal of the cores independently of cement type or root canal anatomy. / O objetivo deste estudo foi avaliar o tempo de remoção de núcleos metálicos utilizando o ultrassom, dentro das variáveis: confecção de alívio, tipo de cimento (fosfato de zinco e ionômero de vidro) e anatomia do conduto radicular (circular e oval). Para isto, foram selecionados 80 dentes humanos higidos unirradiculares (caninos superiores e inferiores, incisivos superiores e pré molares inferiores) com diâmetros radiculares. Os dentes tiveram as coroas removidas e os canais radiculares receberam tratamento endodôntico e posterior alívio de 2/3 do comprimento para receber núcleos metálicos em Ni-Cr. Os dentes foram divididos em 8 grupos (n=10): Grupo 1: conduto circular com fosfato de zinco; Grupo 2: conduto circular com fosfato de zinco; Grupo 3: conduto oval com ionômero de vidro; Grupo 4: conduto oval com ionômero de vidro; Grupo 5: conduto oval com fosfato de zinco; Grupo 6: conduto oval com fosfato de zinco; Grupo 7: conduto circular com ionômero de vidro; Grupo 8: conduto circular com ionômero de vidro. Os grupos 1, 3, 5, 7 sofreram um alívio de aproximadamente 2mm na região da cimentação, ao redor do conduto radicular, entre o núcleo metálico e a porção radicular do dente. Após o procedimento de cimentação, a porção radicular foi inclusa em tubos de PVC com resina acrílica auto-polimerizável. Em seguida as porções coronárias foram vibradas com ultrassom até a remoção e os tempo (s) foi mensurado. Os condutos com anatomia oval requereram maior tempo para remoção dos núcleos metálicos. O alívio confeccionado ao redor do conduto radicular diminui o tempo necessário para realizar a remoção do núcleo independe do tipo de cimento ou forma do conduto.
277

Avaliação da influência de diferentes superfícies na adesão e proliferação de osteoblastos humanos

Guimarães, Magáli Beck January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:05Z (GMT). No. of bitstreams: 2 000422228-0.pdf: 2027786 bytes, checksum: fc45ed715786efb01f83f7fff755ceef (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Nowadays, the focus of many researches in Implant Dentistry is on the modification of the titanium surface in search of alternatives that can provide more quickness and quality to the osseointegration process. Osseointegration is a phenomenon that happens mainly through the interfacial response of bone cells in contact with the titanium surface. There are different treatment methods that can be used to modify the topographic and chemical properties of the titanium surface in order to optimize the tissue-implant reactions. In this study, we evaluated the influence of different titanium surface treatments in the adhesion and proliferation of human osteoblasts by quantitatively analyzing the number of adherent cells in different cell culture periods. Forty level II titanium disks with 15mm diameter and 1mm thickness were divided into four groups according to their surface characterization: G1. machined; G2. acid-etched; G3. with hydroxyapatite coating; and G4. with bisphosphonate immobilized on hydroxyapatite coating. Osteoblast cells derived from human osteosarcoma (SaOS-2) were cultured on the disks and the cell counting was made in 3, 7 and 14 days. To determine the number of cells, a coloring process of the nucleus using propide iodide was carried out and disks were then analyzed in an optical microscope under ultraviolet light. The cell counting in the different experimental groups and culture periods was compared using ANOVA complemented by Tukey’s test. Results of the statistical analysis made it possible to conclude that: (1) the titanium surface and the cell culture period, as well as the interaction of both, significantly affect the cell growth; (2) modifying the titanium surface by acid-etching favors the adhesion and proliferation of human osteoblasts, in vitro. Further researches are necessary to elucidate the immobilized bisphosphonate influence on the titanium surface at the initial osteogenesis events. / Atualmente, o foco de muitas pesquisas científicas em Implantodontia está voltado para a modificação da superfície do titânio na busca de alternativas que proporcionem maior rapidez e qualidade no processo de osseointegração. A osseointegração é um fenômeno que acontece fundamentalmente através da resposta interfacial das células ósseas em contato com a superfície do titânio. Diferentes métodos de tratamento podem ser utilizados para modificar as propriedades topográficas e químicas da superfície do titânio a fim de otimizar as reações tecido-implante. Neste estudo foi avaliada a influência de diferentes tratamentos de superfície do titânio na adesão e proliferação de osteoblastos humanos, através da análise quantitativa do número de células aderidas em diferentes períodos de cultura celular. Para isso, 40 discos de titânio grau II, comercialmente puro, de 15mm de diâmetro e 1mm de espessura, foram divididos em quatro grupos conforme a caracterização de sua superfície: G1. maquinada; G2. ácido-condicionada; G3. com cobertura de hidroxiapatita; e G4. com bisfosfonato imobilizado na cobertura de hidroxiapatita. Células osteoblásticas derivadas de osteossarcoma humano (SaOS-2) foram cultivadas sobre os discos e a contagem celular foi realizada em 3, 7 e 14 dias. Para determinação do número de células, um processo de coloração dos núcleos com Iodeto de Propídio foi realizado, e os discos foram analisados em microscópio óptico sob luz ultravioleta. As contagens celulares nos diferentes grupos experimentais e períodos de cultura foram comparadas por meio de ANOVA, complementado pelo teste de Tukey. Os resultados da análise estatística permitem concluir que: (1) a superfície do titânio e o período de cultura celular, bem como a interação de ambos, significativamente afetam o crescimento celular; (2) a modificação na superfície do titânio através de condicionamento ácido favorece, in vitro, a adesão e proliferação de osteoblastos humanos. Mais pesquisas são necessárias para elucidar a influência do bisfosfonato imobilizado na superfície do titânio nos eventos iniciais da osteogênese.
278

Resistência à fratura de raízes enfraquecidas restauradas com pinos intra-radiculares e submetidas à ciclagem mecânica

Nascimento, Maria Fernanda January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:07Z (GMT). No. of bitstreams: 2 000421649-0.pdf: 1087640 bytes, checksum: faee9bfd7959d4a4a23ff18aca62f774 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This in vitro study evaluated the fracture strength of endodontically treated, weakened root canals, which were restored with either cast metallic or glass fiber-reinforced resin posts (Exacto, Angelus Indústria de Produtos Odontológicos S/A, Londrina, PR, Brazil) and submitted or not to mechanical fatigue. Twenty extracted human teeth with standardized dimensions and no visible structural defects were used. The crowns were cut below the enamel-cement junction to result in 14-16 mm-length roots. The endodontic treatment was performed by using the stepwise technique; the canals were prepared for post insertion with a bur of the glass fiber-reinforced resin post system (# 1. 6 mm-diameter). The roots were weakened by removing intracanal dentin with a tapered diamond bur (4 mm-length) and randomly divided into four groups (n=5/group) according to the type of post (metallic or glass fiber-reinforced resin post) and type of treatment (with or without mechanic cycling). For the metallic posts, the intracanal portion was modeled and cast in Ni-Cr alloy. The resin posts had the crown portion built with nanoparticle composite Z250 (ESPE, 3M) using prefabricated polyesther crowns of standardized shape according to the cast posts. All posts and metallic crowns were cemented with RelyX Unicem. The roots were covered with impression material to simulate the periodontal ligament and embedded in acrylic resin. Two groups were submitted to mechanic cycling with 300,000 cycles, 50 N of load corresponding to a pressure of 1. 13 bars, and frequency of 1 Hz. Specimens were loaded at 45 degrees in a universal testing machine at a crosshead speed of 0. 5 mm/min until failure. The mode of failure was classified as repairable or nonrepairable. The results showed that the metallic posts with no mechanic fatigue had the highest fracture strength (484 N); the resin posts with mechanic cycling showed the lowest values (259. 9 N). The teeth with cast posts had higher strength than the ones with resin posts, but they also showed more nonrepairable failure. Mechanical cycling reduced the fracture strength but did not affect the failure mode. / Este estudo in vitro avaliou a resistência à fratura de raízes enfraquecidas, tratadas endodonticamente, que foram restauradas com pinos metálicos fundidos e pinos de fibra de vidro Exacto (Angelus Indústria de Produtos Odontológicos S/A, Londrina, PR, Brasil) e submetidos à fadiga mecânica. Foram utilizados 20 dentes humanos unirradiculares, extraídos, com dimensões padronizadas e sem defeitos estruturais visíveis. As coroas foram removidas abaixo da junção amelo-cementária, mantendo-se comprimento da raiz entre 14 e 16 mm. O tratamento endodôntico foi realizado pela técnica escalonada; os canais foram desobturados para o preparo intra-radicular padronizado com a broca do sistema de pino de fibra de vidro Exacto (no 1,6 mm de diâmetro). O enfraquecimento radicular foi realizado com remoção de dentina dos condutos com uma broca diamantada tronco-cônica (4 mm de comprimento). As raízes foram aleatoriamente divididas em quatro grupos (n=5/grupo) conforme o tipo de pino (metálico ou pino de fibra de vidro) e o tipo de tratamento realizado (com ciclagem mecânica ou sem ciclagem mecânica). Para os pinos metálicos, a região intra-radicular foi modelada e fundida em peça única em liga de níquel-cromo. Os pinos de fibra de vidro receberam complemento coronário confeccionado com resina nanoparticulada Z250 (ESPE, 3M) com o uso de coroas de poliéster pré-fabricadas com a forma padronizada pelos núcleos fundidos. Todos os pinos e coroas totais metálicas foram cimentadas com o cimento RelyX Unicem. As raízes foram revestidas com uma camada de poliéter simulando o ligamento periodontal e foram embutidas em resina acrílica autopolimerizável. Dois grupos foram submetidos à ciclagem mecânica no Simulador de Fadiga Mecânica ERIOS, modelo ER – 11000, com protocolo de 300. 000 ciclos, carga de 50 N correspondente a pressão de trabalho de 1,13 bars e frequência de 1 Hz.O ensaio mecânico para registro dos valores de resistência à fratura foi realizado com a aplicação de uma carga compressiva a 450 com a face palatina dos corpos-de-prova em máquina de ensaio universal à velocidade de 0,5 mm/min até que houvesse algum tipo de ruptura. O tipo de falha após o ensaio foi classificado como reparável ou irreparável. Os dados de força máxima de ruptura (N) obtidos foram preliminarmente analisados pelos testes de Lilliefors (D) e Shapiro-Wilk (W) quanto à normalidade de sua distribuição para aplicação de testes estatísticos paramétricos. Posteriormente, foram analisados pelo teste ANOVA de acordo com o delineamento de experimento em blocos casualizados com repetições, ao nível de significância de 0,05. Os resultados mostraram que pinos metálicos sem ciclagem mecânica tiveram a maior resistência à fratura (484 N); os pinos de fibra de vidro submetidos à ciclagem mecânica mostraram os menores valores (259,9 N). Os pinos metálicos fundidos apresentaram maiores valores de resistência à fratura que os pinos de fibra de vidro; entretanto, apresentaram maior número de falhas irreparáveis. A ciclagem mecânica reduziu a força máxima de ruptura, mas não afetou o tipo de falha.
279

Duração e seqüência de ativação muscular durante atividades de vida diária em indivíduos dentados e edentados

Cosme, Dúcia Caldas January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:11Z (GMT). No. of bitstreams: 2 000392442-0.pdf: 2886386 bytes, checksum: cb489781ad921d3ccb0830760710c35c (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Several studies have associated oral health to physical performance and muscular activity in different age groups. This study evaluated duration and sequence of muscular activation of masticatory (temporal and masseter), postural head/neck (sternocleidomastoid and trapezius), postural trunk (rectus abdominis and paravertebrals) and low extremity strength muscles (rectus femoris and medial gastrocnemius) during simulation of activities of daily living (ADLs) in two groups: i) Group 1- complete dentures wearers (n=10), and ii) Group 2- young dentate women (n=10). Demographic, anthropometric, and overall health variables were collected. Electromyographic (EMG) activity was recorded during tests of raise of/seat in the chair (TCAD), sit-up/lie down in the bed (TCAM) and lift/lower bags (TSAC), and data of duration (ms) and sequence of muscular activation were computed. In relation to duration of muscular activation, there was influence of occlusal support (PTs) for Group 1 in TCAD: masseter, temporal and sternocleidomastoid muscles had higher values with PTs during the raising movement. Comparing groups 1 and 2, denture wearers had longer activation for the sternocleidomastoid and trapezius muscles in the sitting-up movement. For TSAC, the sternocleidomastoid and gastrocnemius muscles activated longer for group 2, and the rectus femoris muscle for group 1. Regarding sequence of muscular activation, for TCAD, the masseter, sternocleidomastoid, and trapezius muscles showed significant order alteration without PTs in group 1, and a tendency of anticipation of activation for the rectus femoris and gastrocnemius muscles. For TCAM, the presence of PTs had significant effect for the gastrocnemius muscle during the sitting-up phase and the rectus abdominis muscle during the lying down movement, which activated before without occlusal support. For TSAC, there was a significant difference of order for the sternocleidomastoid and trapezius muscles as a function of occlusal support. Comparing groups 1 and 2, there was a significant alteration of sequence of activation for masticatory, postural head/neck, postural trunk, and lower limbs strength muscles in all tests. Anticipation of activation of the paravertebrals, rectus abdominis, and gastrocnemius muscles was observed in dentate young compared to denture wearers. Qualitative evaluation showed large intra- and intersubject variability of the overall muscular activity pattern during the tested movements. In general, these findings suggest that occlusal support and age influenced EMG activity of several muscle groups during simulation of ADLs. / Estudos recentes têm associado a saúde bucal, avaliada através de estabilidade e suporte oclusal, com performance física e atividade muscular em diferentes faixas etárias. Os objetivos deste trabalho foram comparar a duração e a seqüência de ativação dos mm. mastigatórios (mm. temporal e masseter), mm. posturais de cabeça e pescoço (mm. esternocleidomastóideo e trapézio), do tronco (mm. reto abdominal e paravertebrais) e de força das extremidades inferiores (mm. reto femoral e gastrocnêmio medial), durante simulação de atividades de vida diária (AVDs) em dois grupos de mulheres: Grupo 1 - usuárias de próteses totais (PTs) bimaxilares (n=10) e Grupo 2 - dentadas jovens (n=10). Foram coletadas variáveis demográficas, antropométricas e de saúde geral. A atividade eletromiográfica (EMG) foi registrada durante os testes da cadeira (levantar/sentar), da cama (levantar/deitar) e das sacolas (levantar/abaixar), sendo computados os valores de duração de ativação muscular, medidos em ms, e a seqüência de ativação muscular a partir do tempo de latência. Em relação à duração de ativação muscular, houve diferença significativa apenas para o teste da cadeira comparando-se as condições “com e sem PTs” no grupo 1, sendo que os mm. masseter, temporal e esternocleidomastóideo apresentaram maior duração de ativação com PTs no movimento de levantar. Na comparação entre os grupos 1 (com PTs) e 2, o grupo 1 teve maior duração de ativação dos mm. esternocleidomastóideo e trapézio no movimento de levantar da cama. No teste das sacolas, os mm. esternocleidomastóideo e gastrocnêmio apresentaram maior duração de ativação para o grupo 2, e o reto femoral para o grupo 1. Em relação à seqüência de ativação muscular, no teste da cadeira, os mm. masseter, esternocleidomastóideo e trapézio apresentaram alteração significativa com a remoção do suporte oclusal no grupo 1, assim como tendência de antecipação para os mm. reto femoral e gastrocnêmio. Para o teste da cama, houve efeito estatisticamente significativo do suporte oclusal na seqüência de ativação para o m. gastrocnêmio no levantar e m. reto abdominal no deitar, que ativaram antes sem as PTs. Para o teste das sacolas, houve diferença significativa para os mm. esternocleidomastóideo e trapézio em função do suporte oclusal no movimento de abaixar. Comparando os grupos 1 e 2, houve alteração significativa da seqüência de ativação para os mm. mastigatórios, posturais de cabeça e pescoço, posturais do tronco e de força nos três testes. Foi observada antecipação dos mm. paravertebrais, reto abdominal e gastrocnêmio no grupo de dentadas jovens comparada às usuárias de PTs. A avaliação qualitativa dos gráficos de ativação muscular mostrou uma grande variabilidade intra e intersujeito durante os movimentos testados. De modo geral, os resultados sugerem que o suporte oclusal e a idade influenciaram a atividade EMG dos diversos grupos musculares durante os testes de simulação de AVDs.
280

Avaliação da pré-carga e torque de remoção de três parafusos de pilares para próteses unitárias implantossuportadas após ciclagem mecânica

Silva, Fabrício Dorigon da January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:22Z (GMT). No. of bitstreams: 2 000422731-0.pdf: 4008244 bytes, checksum: 02ec9a1844e8d5ae7be399b6caabc500 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study was aimed to compare the preload and removal torque values of three types of screw for transmucosal abutment attachment to single implantsupported prosthesis submitted to cyclic loading test. Ten external hex fixtures (Conexão®, Sistemas de Prótese Ltda. , São Paulo, Brazil) were used, presenting 4,0mm in diameter and 15,0mm in length. Thirty metal crowns were cemented over the abutments Cera One® and attached with its gold, titanium and surface-treated titanium (Torq-Tite®) screws. The screws were attached and the initial preload was recorded. After crown cementation, the samples were placed in a cyclic loading machine and submitted to 400 thousand cycles and a load of 100N. After the test, the preload values were measured through a strain gauge and a measurement cell. Initial and removal torques were measured with an electronic torque control device. Gold screws exhibited the highest preload values (before cyclic 341,00±78,53 N; after cyclic 284,60±72,8 N), followed by surface-treated titanium screws (before cyclic 284,00±70,92 N; after cyclic 195,00±69,28 N) and titanium screws presented the lowest results (before cyclic 235,00±27,39 N after cyclic 196,00±29,66 N). Regarding torque removal values, titanium screws presented the highest values (21,00 ± 0,79 Ncm), followed by gold screws (18,06 ± 1,94 Ncm) and surface-treated titanium screws (16,64 ± 1,38 Ncm). After statistical analysis, ANOVA (p<0,05) e TStudent (p<0,05), significant differences were found between groups for preload, before and after cyclic loading and removal torque. Considering the results, gold screws are the most indicated samples in obtaining joint stability. / Este estudo in vitro teve como objetivo comparar os valores de pré-carga e torque de remoção de três tipos de parafusos de fixação de pilares para próteses unitárias submetidos ao teste de ciclagem mecânica. Foram utilizados 10 implantes hexágono externo (Conexão®, Sistemas de Prótese Ltda. , São Paulo, Brasil) com 4,0mm de diâmetro e 15,0mm de comprimento, nos quais foram cimentadas 30 coroas metálicas sobre abutments Cera One®, fixados com seus respectivos parafusos de ouro, titânio e titânio com tratamento de superfície (Torq-Tite®). Os parafusos foram inseridos e registrou-se a pré-carga inicial. Após cimentação das coroas, as amostras foram posicionadas na cicladora mecânica e submetidas a 400 mil ciclos com freqüência de 1 ciclo/segundo e carga de 100N. Após o teste, foi avaliado o valor de pré-carga produzido com a utilização da célula medidora de carga e extensômetros. Para mensuração dos torques de aperto e remoção, utilizou-se dispositivo eletrônico de controle de torque. Os parafusos de ouro apresentaram os maiores valores de pré-carga (pré-ciclagem 341,00±78,53 N; pós-ciclagem 284,60±72,81 N) em relação aos parafusos de titânio (pré-ciclagem 235,00±27,39 N; pós-ciclagem 196,00±29,66 N) e tratado (pré-ciclagem 284,00±70,92 N; pós-ciclagem 195,00±69,28 N). Para os valores de torque de remoção, os maiores registros foram encontrados para o grupo titânio (21,00 ± 0,79 Ncm), seguido do grupo ouro (18,06±1,94 Ncm) e tratado (16,64±1,38 Ncm). Após análise estatística, ANOVA (p<0,10) e T-Student (p<0,05), foram encontradas diferenças significativas entre os três grupos, para pré-carga, pré e pós-ciclagem e torque de remoção. Devido aos maiores valores de pré-carga obtidos nos resultados do estudo, sugere-se que os parafusos de ouro sejam os mais indicados para obtenção de estabilidade da junta pilar-implante.

Page generated in 0.0559 seconds