• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 13
  • 13
  • 13
  • 13
  • 12
  • 2
  • 1
  • 1
  • Tagged with
  • 139
  • 139
  • 103
  • 88
  • 78
  • 70
  • 58
  • 55
  • 42
  • 42
  • 40
  • 28
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da adaptação marginal e interna de coroas de dissilicato de lítio confeccionadas pelo sistema CAD/CAM após escaneamento direto e indireto / Evaluation of the marginal and internal adaptation of lithium disilicate crowns made by the CAD / CAM system after direct and indirect scanning

Bruna Neves de Freitas 15 December 2017 (has links)
O objetivo desse estudo foi avaliar a adaptação interna e marginal de coroas de dissilicato de lítio obtida por duas técnicas disponíveis pelo sistema CAD/CAM, o escaneamento direto e indireto. As análises foram realizadas por meio do microtomógrafo computadorizado (&microCT), microscópio confocal a laser (CL) e técnica da replica (TR), em dois momentos: antes e após a cristalização do material. O dente 14 de manequim foi preparado e duplicado em silicone, obtendo 20 réplicas em resina de poliuretano. Para a formação do Grupo 1 (IND/n=08), o manequim foi moldado com moldeira de estoque e silicone de adição com técnica de moldagem simultânea e modelagem com gesso pedra tipo III e IV, totalizando oito modelos em gesso. Os modelos foram escaneados com escâner indireto. Foram fresadas oito coroas de dissilicato de lítio. Para formação do Grupo 2 (DIR/n=08), o manequim foi escaneado com escâner direto. Oito imagens foram obtidas e enviadas ao laboratório pelo programa do sistema. Da mesma forma, foram fresadas oito coroas de dissilicato de lítio. As leituras da adaptação marginal das coroas foram realizadas com as mesmas adaptadas sobre a respectiva réplica em poliuretano, no &microCT, CL, e TR. As leituras da adaptação interna foram realizadas no &microCT e TR. As análises foram realizadas antes e após a cristalização das coroas. Os dados que apresentaram distribuição normal foram analisados por ANOVA dois fatores e os dados que não apresentaram distribuição normal foram analisados por teste U de Mann-Whitey para comparação entre os Grupos e pelo teste de Wilcoxon para comparação antes e após a cristalização. Em relação à adaptação axial, foi verificada diferença significante apenas para os Tempos (p=0,017), com menores valores após a cristalização. Para a adaptação interna não foi observada diferença entre os Grupos (p>0,05) ou Tempos estudados (p>0,05). Para a adaptação marginal vertical houve diferença para o Grupo IND, com maiores valores após a cristalização independente da metodologia de análise (&microCT - p=0,001; confocal - p=0,038). Já a medida marginal horizontal apresentou resultados divergentes de acordo com a metodologia utilizada. No &microCT, IND foi maior que DIR (p=0,003) e antes maior que após a cristalização (p<0,001). No confocal, IND menor que DIR após a cristalização (p=0,05), e para DIR, antes menor que após a cristalização (p=0,005). No volume total e volume marginal do espaço para cimentação houve diferença significante apenas para o DIR, com maiores valores após a cristalização (volume total - p=0,025; volume marginal - p=0,002). Pelos resultados obtidos pode-se concluir que há contração do material após a cristalização, resultando em maior desadaptação comprovado pelo aumento do volume total do espaço de cimentação em consequência da dificuldade de assentamento da coroa de dissilicato de lítio. / The objective of this study was to evaluate the internal and marginal adaptation of lithium desilicated crowns obtained by two alternative techniques to the CAD / CAM system, direct and indirect scanning. The analyzes were carried out by computerized microtomograph, laser confocal microscope and replica technique, in two moments: before and after the crystallization of the material. The manikin tooth 14 was prepared for total crown. Then it was duplicated, in silicone, and there were obtained 16 replicas in polyurethane resin. Two groups were formed from the impression of the manikin through the direct and indirect scanning, For the Group 1 (IND/n = 08), the manikin was molded with stock tray, with addition silicone, by the simultaneous molding technique and modeling performed with gypsum stone type III and IV, totaling eight molds and plaster models. The models were sent to the laboratory for scanning on the scanner indirect. Dissilicate crowns were made of lithium milled. For the Group 2 (DIR/n = 08), the dummy was scanned by scanner directly. The eight images obtained were sent directly to the laboratory by the system program. Likewise, milled lithium dissilicate crowns were made. The marginal adaptation of the crowns was performed with the same ones on the respective polyurethane tooth, in the computerized microtomograph (&microCT), confocal laser microscope (CL) and through the replica technique (TR). Internal adaptation readings were performed using a &microCT and TR. The analyses were made before and after the crystallization of the crowns. The data showed normal distribution were analyzed by two factors ANOVA and the data did not show normal distribution were analyzed for U Mann-Whitney test for comparison among groups and by the Wilcoxon test for comparison before and after the crystallization . In relation to the axial adaptation, significant difference was verified only for Times (p = 0.017), with lower values after crystallization. For the internal adaptation was not observed difference between groups (p > 0.05) or Times studied (p > 0.05). For the vertical marginal adaptation difference to the IND group, with higher values after the crystallization analysis methodology-independent (&microCT p = 0.001;-p = 0.038 confocal). Already the measure presented divergent results horizontal marginal according to the methodology used. In &microCT, IND was greater than DIR (p = 0.003) and greater than after the crystallization (p < 0.001). In confocal IND less than DIR after the crystallization (p = 0.05), and DIR, before less than after the crystallization (p = 0.005). In total volume and marginal volume of space for cementation significant difference only to the DIR, with higher values after the crystallization (total volume - p = 0.025; marginal volume - p = 0.002). The results obtained can be concluded that there is contraction of the material after the crystallization, resulting in higher leakage evidenced by the increase of the total volume of the cementing space as a result of the settling difficulty the dissilicate Crown.
122

Estudo comparativo entre um novo método de transferência de planos guias no preparo de boca para Próteses Parciais Removíveis e outras duas técnicas / Comparative study between a new method for tranferring guide planes on mouth preparation for Removable Partial Denture and two other techniques

Cláudio Akira Yamaguchi 18 August 2011 (has links)
A confecção de uma prótese parcial removível exige a correta determinação do eixo de inserção e, consequentemente, o preparo cuidadoso de planos guias para satisfazer os princípios de retenção e estabilidade. Entretanto, grande parte dos profissionais negligencia esta etapa, seja por desconhecimento de sua importância, dificuldade técnica, quantidade limitada de opções cientificamente comprovadas de seus resultados, ou pela aparente e ilusória economia de tempo e de trabalho que sua realização possa tomar. Então, em função do número limitado de técnicas eficientes para transferência de planos guias e da necessidade de um método que otimize o tempo dos profissionais de forma prática e didática, o presente estudo buscou introduzir uma nova maneira de transferir os planos guias. A nova técnica consiste na utilização de uma placa de vacuum-form (PV), comparando-a com preparos realizados em delineador e com duas outras técnicas pré-existentes: à mão livre (ML) e coroas-guia (CG), analisando sua eficácia e precisão. Réplicas idênticas (n=44) de um modelo de gesso representativo da arcada inferior foram divididas em 11 grupos, com 4 modelos cada. Cada um dos onze estudantes de Odontologia recebeu 4 modelos - em um deles os planos guias já tinham sido previamente preparados com delineador, os quais serviram apenas de referência para que fossem empregados os outros métodos. As diferenças angulares dos planos guias nos 44 modelos, nos sentidos ântero-posterior, látero-lateral e cruzado foram mensuradas por meio de uma máquina de medição por coordenadas. A análise de variância para medidas repetidas e o Teste de Comparações Múltiplas (método de Tukey) revelaram que tanto no sentido látero-lateral, como na avaliação cruzada, houve diferença significativa na média dos preparos feitos no delineador em relação a todas as outras técnicas. No entanto, não foram identificadas diferenças importantes entre os três métodos. Para a avaliação ântero-posterior, verificou-se diferença relevante somente entre os preparos feitos no delineador e CG, o que não foi detectado entre ML, PV e delineador. Observou-se também, que os preparos obtidos com delineador apresentaram variações angulares próximos de zero, indicando paralelismo quase absoluto e que os planos guias preparados nesse dispositivo demonstraram média e variabilidade menores que os outros métodos. As demais técnicas (ML, CG e PV) se comportaram de forma estatistica semelhante, exceto no sentido ântero-posterior, onde a CG apresentou maior variação angular. Concluiu-se que a técnica proposta apresentou resultados satisfatórios em relação aos padrões adotados neste estudo, quando comparada às demais técnicas e ao delineador. Portanto, a mesma pode ser considerada viável, já que sua utilização oferece uma confecção de próteses removíveis de forma mais criteriosa, atendendo às necessidades profissionais, em termos de facilidade e tempo gasto em sua execução. / The confection of a removable partial denture requires accurate determination of the path of insertion and consequently, the careful preparation of guide planes to meet the principles of retention and stability. However, a great number of professionals neglect this step because of unconsciousness of its importance, or technical difficulty, or limited options of techniques or because of apparent and illusory saving of time and work. Due to the limited number of proven effective techniques for guide planes preparation and the need of an effective method for optimizing time of dental surgeons in a clear and practical way, this present study aimed the introduction of a new technique for transferring guide planes. The new technique consists on the use of a vacuum form splint (VF). To measure its efficiency and accuracy it was compared with the preparations carried out in a dental surveyor and with two other pre-existing techniques: freehand (FH) and acrylic resin guide crown (GC). Identical replicas (n=44) of a gypsum model representing a dental lower arch were divided into 11 groups of four. Each of the eleven dental students received four models - in one of the models, the guide planes were previously prepared with the surveyor to be used as a reference for the application of the three transfer techniques in the other three remaining models. The angular differences of the the prepared guide planes on the 44 models were measured by a coordinate measuring machine in the anteroposterior, laterolateral and crossed views. The Analysis of Variance and Tukey method revealed that, for the laterolateral evaluation and crossed evaluation, significant differences were found in the average of the preparations obtained by the surveyor in relation to all other techniques. There were no significant differences among the three techniques. Anteroposterior evaluation showed significant difference between the average of the preparations made by the surveyor and by the GC, which was not observed between the FH and PV groups compared to the surveyor. It was also found that the angular variation obtained by preparations using the surveyor was close to zero degree, indicating almost absolute parallelism. The FH, GC and VF techniques were statistically similar, except for the anteroposterior evaluation. In the anteroposterior evaluation the GC presented higher angular variation. It was concluded that the proposed technique showed satisfactory results concerning the adopted standards in the present study when compared with the preparations made by other techniques and the surveyor. Thus, the VF technique can be considered viable, since it improves the quality of the Removable Partial Denture and meets the professional needs, saving time in the procedures.
123

A utilização de um sistema de pontuação (IPB) na avaliação comparativa entre modelos de trabalho encaminhados, para confecção de próteses parciais removíveis / The use of a scoring system (IPB) in the comparative analysis of prosthesis models forwarded for manufacturing removable parcial dentures

Mara Rejane Barreto Alves Rocha 24 September 2012 (has links)
Este estudo avaliou a qualidade dos preparos de boca para confecção de próteses parciais removíveis (PPRs), comparando os preparos realizados na graduação da Faculdade de Odontologia da Universidade de São Paulo (FOUSP), sob supervisão de Docentes, com os preparos realizados por cirurgiões dentistas que solicitaram a confecção dessas próteses a dois laboratórios de Prótese Dentária de São Paulo. As análises foram realizadas em 92 modelos de trabalho, divididos em dois grupos: grupo I, modelos obtidos de pacientes que foram reabilitados na Disciplina de Prótese Removível da FOUSP, por alunos de graduação, e grupo II, modelos obtidos de pacientes que foram reabilitados por vários profissionais, e que foram recolhidos dos referidos laboratórios. Foi utilizado como instrumento de avaliação, o Índice de Preparo de Boca modificado (IPB), com o objetivo de avaliar comparativamente, os dois grupos, quanto a Distribuição, Localização e Forma dos descansos oclusais e de cíngulo; Presença, Distribuição e Paralelismo dos planos-guia; Características dos pontos de calibragem; e a diferença estatística dos valores do IPB, entre os grupos. Ainda foi investigada a prevalência da classificação de Kennedy (para pacientes desdentados parciais), nos dois grupos de modelos. O método estatístico utilizado foi o teste não paramétrico de Mann-Whitney. Baseado nos resultados encontrados, concluiu-se que os preparos de boca dos trabalhos realizados na Faculdade de Odontologia da Universidade de São Paulo (grupo I, modelos-USP) foram significativamente melhores do que aqueles elaborados por profissionais, cirurgiões dentistas que enviaram os modelos de seus pacientes aos laboratórios, para confecção de PPRs (grupo II, modelos-Laboratórios). Não houve associação estatisticamente significante entre os grupos de modelos no que se refere à classificação de Kennedy. / This study analysed the quality of mouth preparations for manufacturing removable parcial dentures (RPDs) by comparing preparations made by undergraduates at Faculdade de Odontologia da Universidade de São Paulo (FOUSP) working under the supervision of staff teachers with preparations made by dentist surgeons who had sent prostheses to two dental prosthesis laboratories in São Paulo for manufacturing. Analyses were carried out in 92 models divided in two groups: group I, models obtained from patients rehabilitated by undergraduates in the subject Removable Prosthesis at FOUSP and group II, models obtained from patients rehabilitated by several professional dentist surgeons and collected at the two laboratories mentioned above. The instrument of assessment used was the modified Mouth Preparation Ratio (IPB), aiming at assessing the two groups comparatively concerning the Distribution, Location and shape of rest bite and cingulum occlusion, Presence, Distribution and Paralelism of guide planes; Characteristics of the calibration points; and the statistical difference in IPB values between the two model groups. The prevalence of the Kennedy classification (for parcially toothless patients) was also investigated in both model groups. The statitical method used in both groups was the Mann-Whitney non-parametric test. Based on the results achieved, it was concluded that mouth preparations made at Faculdade de Odontologia da Universidede de São Paulo (group I, USP models) were significantly better than those made by professional dentist surgeons who had sent their patients models to the dental laboratories for manufacturing RPDs (group II, lab models). There was no statistically significant association between both groups concerning the Kennedy classification.
124

Prótese parcial fixa em pacientes com fissura labiopalatina / Fixed partial prosthesis in patients with cleft lip and palate

Mariana Gelmini 18 November 2011 (has links)
Introdução: A ausência do incisivo lateral superior é freqüente em indivíduos com fissuras que envolvem o rebordo alveolar. As próteses parciais fixas convencionais, apesar de se tratar de procedimento não conservativo devido ao desgaste dos dentes adjacentes à fissura, podem oferecer resultados funcional e estético satisfatórios. Objetivos: Avaliar a estética da prótese e do sorriso após reabilitação com prótese parcial fixa na área da fissura, avaliar clinicamente as condições biológicas do periodonto de proteção na área correspondente à prótese e analisar o grau de satisfação dos pacientes após tratamento. Material e Métodos: Foram selecionados 40 pacientes, de ambos os gêneros, com fissura transforame incisivo e pré-forame incisivo unilateral completa, reabilitados com prótese parcial fixa na área do incisivo lateral superior ausente. Esses foram fotografados, para posterior análise por três grupos de examinadores, que classificaram a estética das próteses como agradável, aceitável e desagradável. Questionários e escala analógica visual foram utilizados para avaliar o grau de satisfação dos pacientes. Para análise estatística foram obtidos valores médios, mediana e desvio padrão e utilizados coeficiente Kappa conforme caracterizado por Landis e Koch (1977), teste de Kruskal Wallis e coeficiente de Spearman, adotando-se nível de significância 5%. Resultados: A fissura transforame incisivo unilateral correspondeu a 62,5% dos casos. Não houve diferença estatisticamente significante entre os grupos de examinadores, que consideraram prótese esteticamente aceitável e a concordância interjuízes foi considerada de moderada a substancial. Para os pacientes, a estética da prótese foi considerada satisfatória para 65% e aceitável para 22,5%. Conclusão: A maioria dos casos clínicos foi considerada prótese esteticamente aceitável, sendo que as próteses devem ser melhoradas no que diz respeito à curvatura incisal e tamanho das coroas. A ausência de papila gengival e sua reposição artificial foram observadas na maioria dos casos clínicos. A maioria dos pacientes considerou a prótese satisfatória em relação à estética e também em relação à estética do sorriso; mais estudos tornam-se necessários para se alcançar excelência no tratamento dos pacientes com fissuras. / Introduction: The absence of the lateral incisor is frequent in individuals with clefts involving the alveolar crest. The conventional prosthesis fixed partial , despite the fact that isn´t a conservative procedure, may offer results functional and aesthetic satisfactory. Objectives: To evaluate the aesthetics of the prosthesis and the smile after rehabilitation with prosthesis fixed partial in the area of the cleft, to evaluate clinically the biological conditions of the periodontium of protection in the area corresponding to the prosthesis installed and analyze the degree of patient satisfaction after treatment. Material and Methods: The sample included 40 patients of both genders, with complete unilateral cleft lip and palate, rehabilitated with partial prosthesis sets in the area of the lateral incisor absent. These patients were photographed for later analysis by groups of examiners, the prostheses of the patients were classified as aesthetically pleasing, aesthetically acceptable and aesthetically unpleasant. Questionnaires and visual analog scale were used to assess the degree of satisfaction of the patients after treatment received. For the statistical analysis the average values, median and standard deviation was obtained and by the use Kappa coefficient in agreement with Landis and Koch (1977), Kruskal Wallis Test and Spearman coefficient, with a 5% significance level adopted. Results: The unilateral cleft lip and palate accounted for 62.5% of cases. There was no statistically significant difference between the groups of examiners, was identified in all the cases aesthetically acceptable prosthesis, and the agreement of interjudges was considered moderate to substancial. For patients, the treatment was satisfactory in 65% of the cases, while22.5% considered acceptable. Conclusion: Most clinical cases was considered aesthetically acceptable prostheses with the dentures should be improved with respect to the curvature and size of incisal crowns. The absence of gingival papilla and its artificial replacement were observed in most clinical cases. Most patients considered satisfactory prosthesis in relation to aesthetics and also in relation to aesthetics of the smile, but do not consider acceptable in relation to aesthetic of the prosthesis, more studies are needed to achieved excellence in the treatment gives patients.
125

Força de mordida em pacientes com fissura labiopalatina reabilitados com próteses parciais fixas sobre dentes naturais e implantes / BITE FORCE IN PATIENTS WITH REHABILITATED CLEFT LIP AND PALATE WITH PARTIALLY FIXED PROSTHESES ON NATURAL TEETH AND IMPLANTS

Rafael D'Aquino Tavano 31 July 2015 (has links)
As fissuras palatinas além de envolvem o osso alveolar podem promover a ausência do dente incisivo lateral ou apresenta-lo severamente comprometido. Nesses casos sua reabilitação poderá ser feita por próteses parciais fixas convencionais ou por prótese sobre implantes, geralmente após uma cirurgia de enxerto ósseo na região. Todavia além da estética, se faz necessário investigar sobre o potencial de força oclusal que essas reabilitações proporcionam. Assim, o propósito desse estudo foi avaliar a força máxima de mordida em indivíduos com fissura labiopalatina unilateral reabilitados com prótese parcial fixa convencional e sobre implantes e comparar esses resultados com o lado contralateral e com indivíduos sem fissura. A amostra foi constituída por 50 indivíduos, 25 pacientes com fissura (15 reabilitados com próteses parciais fixas convencionais e 10 sobre implantes) e 25 indivíduos sem fissura com dentes naturais. A força de mordida máxima foi mensurada por um único examinador utilizando o gnatodinamômetro, registrado nas regiões reabilitadas de incisivo lateral e canino, região de molares e incisivos centrais. Os valores médios obtidos, e a análise estatística com os testes t de Student e t de Student pareado permitiram observar que no mesmo indivíduo, a força de mordida do lado não afetado foi estatisticamente superior quando comparado com o lado da fissura reabilitado com prótese (p=0,005). O grupo reabilitado com prótese fixa convencional apresentou a força máxima de mordida estatisticamente igual ao grupo com prótese fixa sobre implante (p=0,781). Considerando os grupos experimental e controle na região de molares os resultados foram estatisticamente iguais (lado afetado p=0,082 e não afetado p=0,066). Na região de incisivo lateral e canino, o lado correspondente ao afetado no grupo-controle, apresentou força máxima de mordida estatisticamente maior que o grupo-experimental (p=0,004), enquanto no lado correspondente ao não afetado os resultados foram iguais. Na região de incisivos centrais o resultado médio do grupo-controle também foi estatisticamente maior que o experimental (p=0,005) / The cleft palate involving the alveolar bone may have the lateral incisor tooth missing or severely compromised. In such cases rehabilitation can be done through fixed dental prostheses or implant-supported fixed dental prostheses, generally after a bone graft surgery in the region. However, beyond aesthetics, it is necessary to investigate the potential for occlusal force that these rehabilitations provide. Thus, the purpose of this study was to evaluate the maximum bite force in subjects with unilateral cleft lip and palate rehabilitated with fixed dental prostheses or implantsupported fixed dental prostheses and compare the results with the contralateral side and with individuals without cleft. The sample consisted of 50 subjects, 25 patients with cleft (15 rehabilitated with fixed dental prostheses and 10 with implant-supported fixed dental prostheses) and 25 individuals without cleft and with natural teeth. The maximum bite force was measured by means of gnathodynamometer, registered in the rehabilitated lateral incisor and canine region, molars region and incisors regions by a single examiner. The obtained average values, and the statistical analysis with the Student t test and paired Student t test allowed to be observed that on the same individual the bite force on the side that was not affected was statistically superior when compared to the side of the rehabilitated cleft with prosthesis (p=0,005). The rehabilitated group with conventional prostheses presented maximum bite force statistically equal to the group with the implant-supported fixed dental prostheses (p=0,781). Considering the experimental and control groups on the molar regions, the results were statistically equal (affected side p=0,082 e non-affected p=0,066). The lateral incisor and canine region from the correspondent affected side on the control group presented maximum bite force statistically higher than the experimental group (p=0,004), on the non-affected side the results were the same. In the incisor region, the average result of the control group was also statistically higher than the experimental group (p=0,005)
126

Influência da inserção de fibras de Al2O3/GdAlO3 na resistência mecânica de monolayers e bilayers de cerâmicas odontológicas / Flexural strength of ceramic monolayers and bilayers bars reinforced by Al2O3/GdAlO3 fibers

Ricardo Sgura 20 May 2010 (has links)
O presente estudo avaliou a adição de fibras cerâmicas de 0,5mm de diâmetro de Al2O3/GdAlO3 obtidas por fusão a laser (método LHPG - laser heated pedestal growth) em porcelanas de cobertura dos sistemas In Ceram Alumina, In-Ceram 2000 Al Cubes e In-Ceram 2000 YZ Cubes para CEREC (VITA Zahnfabrik). Barras confeccionadas apenas com a porcelana de cobertura (VM7 ou VM9 - monolayers) ou constituídas por ambas a cerâmica da infraestrutura e porcelana de cobertura (bilayers) receberam as fibras dispostas longitudinalmente nas proporções de 10 ou 17% vol. Barras que não receberam fibras serviram como controle dos grupos. Os corpos-de-prova (CP) com fibras assim como os do grupo controle foram submetidos a um teste de flexão em três pontos. Foram calculadas as médias para a densidade e resistência à flexão dos CP, assim como para as fibras isoladamente. A tenacidade à fratura das fibras também foi mensurada. Em todos os casos a análise de variância de um fator e o teste de Tukey com 5% de significância foram aplicados. Microscopia eletrônica de varredura foi utilizada para caracterização microestrutural das fibras e para estudo fractográfico. Foram realizadas análises de difratometria por raio-x dos materiais cerâmicos nos estados pré e pós-sinterização, assim como foram determinados os coeficientes de expansão térmico-linear das porcelanas de cobertura por dilatometria. Os CP monolayers da porcelana VM9 contendo fibras apresentaram, após a sinterização, trincas e falhas, o que impediu a continuidade dos testes com os grupos de cerâmicas do sistema In-Ceram 2000 YZ Cubes. Os CP com fibras adicionadas à porcelana VM7 em 17% vol. apresentaram resistência à flexão aumentada em 43% comparados aos CP do grupo controle, sem fibras. Nos grupos bilayers as fibras propiciaram aumento apenas numérico da resistência à flexão do conjunto, porém de forma não significante. / This study evaluated the addition of 0.5mm of diameter Al2O3/GdAlO3 fibers obtained by LHPG (Laser Heated Pedestal Growth) to veneering porcelains of the following materials: porcelain monolayers: VM7 and VM9; Bilayers: In-Ceram Alumina + VM7, In-Ceram 2000 AL Cubes + VM7 and In-Ceram 2000 YZ Cubes for CEREC + VM9 (VITA Zahnfabrik). The specimens (bars) were composed by only the veneer porcelain (monolayer) or both the veneer and the framework (bilayer). The new ceramic composites contained longitudinal fibers in 10 or 17% vol. Specimens without fibers were used as control. A metallic device was developed for the standardization of the fibers position inside the specimens. The means of the fracture toughness, density and flexural strength of the developed fibers were calculated as well as the density and flexural strength of the composites. One way ANOVA and a Tukey test (5%) were applied. Characterizations of fiber/porcelain interface and fractographyc analysis were carried out after scanning electronic microscopy (SEM) of bars. X-ray difratometry and dilatometry were also performed. Vm9 porcelain showed incompatibility with the fibers, probably due to differences between the coefficients of thermal expansion of fibers and porcelain. VM7 monolayers with the addition of 17% of fibers in volume showed significantly higher resistance in relation to control. It was concluded that the inclusion of ceramic fibers of Al2O3/GdAlO3 to veneer porcelain improves its flexural strength.
127

Potencial inflamatório de duas técnicas para afastamento gengival utilizadas durante procedimentos protéticos / Inflammatory potential of two techniques used for gingival retraction during restorative procedures

SARMENTO, Hugo Ramalho 18 March 2013 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1 Dissertacao_hugo_ramalho.pdf: 1163967 bytes, checksum: 5735b7a46397cc9fceb1883f7a66141c (MD5) Previous issue date: 2013-03-18 / This study was composed by two phases that evaluated two gingival displacement (GD) techniques, conventional and cordless: 1- a in vitro study which assess cytoxicity/genotoxicity, and pH of AlCl3-based agents; and 2- a randomized clinical which evaluated the efficacy of these techniques. For in vitro phase, eluates were obtained by dilution of AlCl3-based into culture medium for 1h, 4h, and 24h. pH values were measured by digital pHmeter, cytotoxicity by MTT test and genotoxicity by Micronuclei test. A crossover, double-blind, randomized clinical trial was designed to evaluate clinical, immunologic and individual factors before and after GD by two techniques, conventional (gingival cord + astringent gel) and cordless (astringent-based paste). These factors were evaluated on incisors prepared for metal-ceramic dental crowns before, 1 day post-GD and 10 day post-GD. Interleukin 1&#946;, Interleukin 6 and Tumor Necrosis Factor &#945; concentrations were evaluated on gingival crevicular fluid collected before (control) and 1 day post-GD. In vitro data were analyzed by two-way ANOVA and Tukey test. Clinical data were analyzed by One-way Repeated Measures ANOVA and Tukey test (immunologic factor), Friedman test (periodontal parameters), and Fisher Exact or Qui-square test (pain, stress, and unpleasant flavor during GD). All test were realized considering p<0.05. Mean pH values were statistically higher for Viscostat than Expasyl. Both astringents were non-cytotoxic at 1h. Expasyl was more cytotoxic than Viscostat at 4h and 24h. Expasyl genotoxicity was not different from control group. Neither of the two evaluated techniques resulted in worse periodontal indices. Conventional technique was statistically more stressing than cordless, and similar considering pain and unpleasant taste. GD by the both 11 treatments evaluated led to statistically higher mean concentrations of the three interleukins evaluated. Conventional GD technique resulted in the highest interleukins levels. In vitro, AlCl3-based astringents presented acceptable biological activity with no genotoxic difference between Expasyl and control group. In vivo, cordless technique was less stressful and resulted in lower cytokines levels after GD / Este estudo foi composto por duas fases que avaliaram duas técnicas para afastamento gingival (AG), convencional e sem fio: 1- um estudo in vitro que avaliou acitotoxicidade/genotoxicidade, e o pH de agentes à base de AlCl3; e 2- um ensaio clínico randomizado que avaliou a eficácia destas técnicas. Na fase in vitro, eludatos foram obtidos pela diluição dos eluates agentes à base de AlCl3 em meio de cultura por 1h, 4h e 24h. Os valores de pH foram aferidos por pHmetro digital, citotoxicidade pelo teste MTT e genotoxicidade pelo teste do Micronúcleo. Um ensaio clínico randomizado, cruzado, duplo-cego foi concebido para avaliar fatores clínicos, imunológicos e individuais antes e após AG por duas técnicas, convencional (C: fio gengival + gel adstringente) e sem fio (SF: pasta à base de adstringente). Estes fatores foram avaliados em incisivos preparados para coroas metalo-cerâmicas antes, 1 dia e 10 dias após AG. As concentrações de Interleucina 1&#946;, Interleucina 6 e Fator de Necrose Tumoral &#945; foram avaliadas no fluido gengival crevicular coletado antes (controle) e 1 dia após AG. Os dados do estudo in vitro foram analisados por ANOVA 2-fatores e teste de Tukey. Os dados do ensaio clínico foram analiados por ANOVA para medidas repetidas e teste de Tukey (fator imunológico), teste de Friedman (parâmetros periodontais), e Exato de Fisher ou teste Qui-quadrado (dor, estresse e sabor desagradável). Todos os testes consideraram p<0.05. Os valores médios de pH foram estatísticamente superiores para C que para SF. As técnicas não foram citotóxicas no tempo de 1h. SF foi mais citotóxica que C em 4h e 24h. A genotoxicidade SF foi semelhante à do grupo controle. Nenhuma das técnicas avaliadas resultou em piora nos indices periodontais. Atétnica C foi mais estressante 9 que a SF, e semelhantes considerando dor e sabor desagradável. AG realizado por ambas as técnicas levou a maiores concentrações médias das três citocinas avaliadas. C resultou nos maiores níveis de interleucinas. In vitro, os adstringentes apresentaram atividade biológica aceitável, sem diferença na genotoxicidade entre as técnicas. In vivo, SF foi menos estressante e resultou em menores níveis de citocinas após AG
128

Síntese, caracterização e ação antimicrobiana de óxidos bimetálicos e de revestimentos depositados à plasma sobre resina acrílica /

Foggi, Camila Cristina de January 2017 (has links)
Orientador: Ana Lucia Machado / Resumo: Devido ao aumento da tolerância dos microrganismos aos antimicrobianos atualmente disponíveis, existe a necessidade de desenvolvimento de métodos alternativos para o controle das infecções. Na primeira etapa dessa pesquisa, óxidos bimetálicos foram sintetizados por meio dos métodos hidrotermal assistido por micro-ondas e co-precipitação, variando-se as condições de síntese, como temperatura, pH, utilização ou não de surfactantes e tipos de solventes. Os diferentes microcristais de tungstato de prata (α-Ag2WO4) e molibdato de prata (β-Ag2MoO4) obtidos foram caracterizados por difração de Raios X (DRX), microscopia eletrônica de varredura por emissão de efeito de campo (MEV-EC), microscopia eletrônica de transmissão (MET), espectroscopia de energia dispersiva de raios-X (EDX), espectroscopia Raman e mensurações de fotoluminescência (PL) e UV-Vis. A atividade antimicrobiana desses compostos contra células planctônicas de Staphylococcus aureus resistente à meticilina - SARM, Escherichia coli (E. coli) e Candida albicans (C. albicans) foi avaliada por meio da determinação das concentrações inibitórias (CIM) e bactericida/fungicida mínimas (CBM/CFM). Além disso, com base nos testes de CIM, CBM e CFM, os compostos que proporcionaram os melhores resultados (α-Ag2WO4 irradiado e α-Ag2WO4 e β-Ag2MoO4, ambos sintetizados em álcool) foram também avaliados quanto à inibição da formação de biofilmes de SARM, E. coli e C. albicans, através de contagem de unidades formadoras de colônias por ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Due to the increased tolerance of the microrganisms to the available antimicrobial drugs, there is a need of development of alternative methods for infection control. In the first part of this study, bimetallic oxides were synthesized by hydrothermal microwave-assisted and coprecipitation methods, varying synthesis conditions, as presence or absence of surfactants and types of solvents used. The different microcrystals of α-Ag2WO4 and β-Ag2MoO4 obtained were characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), energy diffraction spectroscopy (EDS), Raman spectroscopy and photoluminescence measurements (PL) and UV-Vis. Their antimicrobial activity was evaluated against planktonic cells of methicillin - resistant Staphylococcus aureus - MRSA, Escherichia coli (E. coli) and Candida albicans (C. albicans) by the determination of inhibitory concentrations (MIC) and bactericidal/fungicidal concentrations (MBC/MFC). Based on the MIC, MBC and MFC values, the microcrystals that provided the best results (α-Ag2WO4 irradiated and α-Ag2WO4 and β-Ag2MoO4, both synthesized in alcohol) were also evaluated for their ability to inhibit biofilm of MRSA, E. coli and C. albicans, by counting the CFU/mL, dry weight determination, and analysis using confocal laser scanning microscopy (CLSM) and FE-SEM. Other method for infection control evaluated in the second part of this research, was the deposition of SiO2/Ag thi... (Complete abstract click electronic access below) / Doutor
129

"Análise comparativa pelo método dos elementos finitos bidimensional das tensões geradas nas estruturas de suporte de prótese parcial removível de extremidade livre inferior sobre rebordo residual ascendente distal e descendente distal"

Camargo, Renato Zanutto Bueno de 14 April 2005 (has links)
Nesta pesquisa, foi realizada uma análise comparativa, por meio do método dos elementos finitos bidimensional linear, das deformações e tensões geradas a partir da aplicação de uma carga de 100N, nas estruturas de suporte (fibromucosa,ligamento periodontal, osso cortical e osso esponjoso) de dois modelos que simulam um hemiarco mandibular associada a uma prótese parcial removível de extremidade livre dista inferiorl, quando da variação da inclinação do rebordo residual no plano sagital. O modelo A (MA) foi desenhado com um rebordo ascendente distal com 15 graus de inclinação e o modelo B (MB) com um rebordo descendente distal com 15 graus negativos, ambos em relação ao plano oclusal. Nos dois modelos aplicou-se uma carga primeiramente na cúspide médio-vestibular do primeiro molar inferior artificial (C1) e depois na cúspide vestibular do segundo pré-molar inferior (C2), por meio do programa I-deas (software de elementos finitos) onde foram feitas as análises de deformações e tensões e processamento das imagens. Fez-se então uma análise comparativa dos carregamentos (C1 e C2) em cada modelo individualmente e entre os dois modelos(MA e MB). Os resultados permitiram concluir que: 1) A inclinação do rebordo residual no plano sagital influenciou na distribuição e na intensidade das tensões das estruturas de suporte; 2) No osso cortical as tensões foram mais localizadas e de maior intensidade que no osso esponjoso; 3) A diferença de deformação entre fibromucosa e ligamento periodontal foi maior quando a carga foi aplicada no primeiro molar, de ambos os modelos, sendo a mais expressiva no rebordo ascendente distal; 4) As tensões de compressão foram maiores em intensidade e melhor distribuídas no osso esponjoso e no osso cortical, quando comparadas as tensões de tração; 5) O rebordo ascendente distal se mostrou mais favorável à distribuição das tensões nas estruturas de suporte quando comparado ao rebordo descendente distal; 6) Nos dois modelos a aplicação da carga no primeiro molar gerou um maior torque sobre o dente suporte para a distal do que quando aplicado no segundo pré-molar, principalmente no rebordo descendente distal; 7) As estruturas de suporte do rebordo residual foram mais solicitadas em C1 que em C2, em ambos os modelos, principalmente no rebordo ascendente distal; 8) No dente suporte as tensões nas estruturas de suporte foram mais axiais quando o carregamento ocorreu no segundo pré-molar inferior, em ambos os modelos. / In this study, a two-dimensional finite element comparative analysis of the stress distribution and of displacement in the supporting structures – oral mucosa,periodontal ligament, compact and cancellous bone – was carried out for a distal extension base removable partial denture (RPD), modeled on two mandibular dental archs with different types of residual ridge when aplaying loads of 100N. The A model (MA) was developed to include a distal ascending alveolar ridge with a 15-degrees positive inclination, while the B model (MB) was prepared with a distal descending alveolar ridge with a 15-degrees negative inclination. Both models had a load applied inicially on the lower first molar median cusp (C1) and then on the lower second premolar buccal cusp (C2). Using the FEA software (I-DEAS, USA) for the stress distribution and displacement analysis of the generated images. A comparative analysis was them performed on the C1 and C2 loads for which and both models (MA and MB).The results showed that: 1 – The alveolar ridge inclination showed some degree of on the stress distribution and intensity generated by the RPD; 2 –The compact bone showed greater stress concentration and intensity than the cancellous bone; 3 – The ratio between oral mucosa and periodontal ligament displacement showed greater values when load was applied on the lower first molar for both models. The ratio was higher for the distal ascending alveolar ridge; 4- The compressive stress showed greater intensity and better range of distribution than the tensile stress for both the compact and cancellous bone; 5 – The distal ascending residual ridge had a more favourable stress distribution than distal descending conterpart ; 6 – The load applied on the lower first molar produced more distal torquing on the supporting tooth than that on the lower second premolar ,specially on the distal descending residual ridge; 7 – the load applied on the lower firt molar generated greater amount of stress on the residual ridge supporting structures for both models, but specially for the distal ascending residual ridge; 8 – The load applied on the lower second premolar produced more vertical forces on the supporting structures of the tooth for both models.
130

Efeito de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio na superfície da liga metálica de cobalto cromo / Effect of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride on the surface of the cobalt chromium alloy

Curylofo, Patricia Almeida 24 January 2017 (has links)
A longevidade da prótese e a saúde bucal de usuário de Prótese Parcial Removível (PPR) são muito dependentes de higiene apropriada. O objetivo deste estudo foi comparar o efeito de soluções de Ricinus communis, em diferentes concentrações, com soluções de peróxido alcalino e cloreto de cetilpiridínio, em relação à liga metálica de Cobalto Cromo (Co-Cr) que compõe a estrutura de PPR. A amostra do experimento foi composta por 55 espécimes de Co-Cr, confeccionados a partir de padrões de cera circulares (12 mm x 3 mm) obtidos a partir de uma matriz metálica. Os padrões foram fundidos, numerados aleatoriamente e divididos em 5 grupos de imersão: H2O- água deionizada (controle) (15 minutos); Rc 2%- Ricinus communis 2% (20 minutos), Rc 10% -Ricinus communis 10% (20 minutos), PA- peróxido alcalino (15 minutos) e CCP- cloreto de cetilpiridínio 0,500 mg (10 minutos). Os espécimes foram avaliados quanto à rugosidade de superfície (n=10) no início e após a simulação de 6 meses, 1, 2, 3, 4 e 5 anos tanto pelo microscópio confocal a laser (Sa, &micro;m), como também pelo rugosímetro de superfície (Ra, &micro;m). Um espécime de cada grupo foi analisado quanto à topografia de superfície (Microscopia Eletrônica de Varredura, MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS) antes e após simulação de uso por 5 anos. De acordo com os resultados obtidos (&alpha;=0,05) pela microscopia confocal (Sa), não houve diferença para o fator solução (Kruskal-Wallis); para o fator tempo (Friedman) houve diferença estatística em Rc 2% entre T0 e T1, T3, T4 e T6 (p<0,001) e em Rc 10% de T2 para T3 (p=0,007), com diminuição da rugosidade. Com o rugosímetro (Ra), houve diferença estatística (Kruskal- Wallis) para CCP que apresentou menor rugosidade em relação à Rc 10% em T1 (p=0,048) e T6 (p=0,013). Em relação ao tempo (Friedman), a água propiciou diminuição da rugosidade superficial (Ra) de T0 para T2 (p=0,013). Na análise de MEV e EDS podese verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que embora tenha sido encontrada diferença estatística para a rugosidade, os resultados são clínicamentes aceitáveis. Deste modo, todas as soluções podem ser utilizadas com segurança pelo período de 5 anos. / Denture longevity and oral health of Removable Partial Denture (RPD) user are highly dependent on proper hygiene. The aim of this study was to compare the effect of solutions of Ricinus communis, in different concentrations, with solutions of alkaline peroxide and cetylpyridinium chloride 0.500 mg, in relation to the Cobalt Chromium (Co-Cr) alloy that composes the structure of RPD. The sample of the experiment consisted of 55 specimens of Co-Cr, made from circular wax patterns (12 mm x 3 mm) obtained in a metal matrix. The patterns were cast, randomly enumerated and divided into 5 immersion groups: H2Odeionized water (control) (15 minutes); Rc 2%- Ricinus communis 2% (20 minutes), Rc 10% -Ricinus communis 10% (20 minutes), PA-alkaline peroxide (15 minutes) and CCPcetylpyridinium chloride 0.500 mg (10 minutes). The specimens were evaluated for surface roughness (n = 10) at the beginning and after the simulation of 6 months, 1, 2, 3, 4 and 5 years by the laser confocal microscope (Sa, &micro;m) and by the rugosimeter of surface (Ra, &micro;m). One specimen from each group was analyzed for surface topography (Scanning Electron Microscopy, SEM) and Energy-dispersive X-ray spectroscopy (EDS) befofe and after simulation of use for 5 years. According to the results obtained (&alpha;= 0.05) by confocal microscopy (Sa), there was no difference for the solution factor (Kruskal- Wallis); For the time factor (Friedman) there was a statistical difference in Rc 2% in T0 to T1, T3, T4 and T6 (p <0.001) and Rc 10% in T2 to T3 (p = 0.007), with decrease in roughness. With the the rugosimeter (Ra), there was a statistical difference (Kruskal- Wallis) for CCP that presented less roughness in relation to the Rc 10% in T1 (p = 0.048) and T6 (p = 0.013). In relation to the time, (Friedman) the water caused a reduction of surface roughness (Ra) between T0 and T2 (p = 0.013). In the analysis of SEM and EDS it can be verified that the solutions did not present deleterious effects on the surfaces. It was concluded that although a statistical difference was found for roughness, the results are clinically acceptable. Thus, all solutions can be safely used for a period of 5 years.

Page generated in 0.0819 seconds