• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • 10
  • 10
  • 10
  • 10
  • 9
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 78
  • 78
  • 58
  • 58
  • 48
  • 39
  • 29
  • 28
  • 22
  • 15
  • 15
  • 14
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação da adaptação marginal e interna de coroas de dissilicato de lítio confeccionadas pelo sistema CAD/CAM após escaneamento direto e indireto / Evaluation of the marginal and internal adaptation of lithium disilicate crowns made by the CAD / CAM system after direct and indirect scanning

Bruna Neves de Freitas 15 December 2017 (has links)
O objetivo desse estudo foi avaliar a adaptação interna e marginal de coroas de dissilicato de lítio obtida por duas técnicas disponíveis pelo sistema CAD/CAM, o escaneamento direto e indireto. As análises foram realizadas por meio do microtomógrafo computadorizado (&microCT), microscópio confocal a laser (CL) e técnica da replica (TR), em dois momentos: antes e após a cristalização do material. O dente 14 de manequim foi preparado e duplicado em silicone, obtendo 20 réplicas em resina de poliuretano. Para a formação do Grupo 1 (IND/n=08), o manequim foi moldado com moldeira de estoque e silicone de adição com técnica de moldagem simultânea e modelagem com gesso pedra tipo III e IV, totalizando oito modelos em gesso. Os modelos foram escaneados com escâner indireto. Foram fresadas oito coroas de dissilicato de lítio. Para formação do Grupo 2 (DIR/n=08), o manequim foi escaneado com escâner direto. Oito imagens foram obtidas e enviadas ao laboratório pelo programa do sistema. Da mesma forma, foram fresadas oito coroas de dissilicato de lítio. As leituras da adaptação marginal das coroas foram realizadas com as mesmas adaptadas sobre a respectiva réplica em poliuretano, no &microCT, CL, e TR. As leituras da adaptação interna foram realizadas no &microCT e TR. As análises foram realizadas antes e após a cristalização das coroas. Os dados que apresentaram distribuição normal foram analisados por ANOVA dois fatores e os dados que não apresentaram distribuição normal foram analisados por teste U de Mann-Whitey para comparação entre os Grupos e pelo teste de Wilcoxon para comparação antes e após a cristalização. Em relação à adaptação axial, foi verificada diferença significante apenas para os Tempos (p=0,017), com menores valores após a cristalização. Para a adaptação interna não foi observada diferença entre os Grupos (p>0,05) ou Tempos estudados (p>0,05). Para a adaptação marginal vertical houve diferença para o Grupo IND, com maiores valores após a cristalização independente da metodologia de análise (&microCT - p=0,001; confocal - p=0,038). Já a medida marginal horizontal apresentou resultados divergentes de acordo com a metodologia utilizada. No &microCT, IND foi maior que DIR (p=0,003) e antes maior que após a cristalização (p<0,001). No confocal, IND menor que DIR após a cristalização (p=0,05), e para DIR, antes menor que após a cristalização (p=0,005). No volume total e volume marginal do espaço para cimentação houve diferença significante apenas para o DIR, com maiores valores após a cristalização (volume total - p=0,025; volume marginal - p=0,002). Pelos resultados obtidos pode-se concluir que há contração do material após a cristalização, resultando em maior desadaptação comprovado pelo aumento do volume total do espaço de cimentação em consequência da dificuldade de assentamento da coroa de dissilicato de lítio. / The objective of this study was to evaluate the internal and marginal adaptation of lithium desilicated crowns obtained by two alternative techniques to the CAD / CAM system, direct and indirect scanning. The analyzes were carried out by computerized microtomograph, laser confocal microscope and replica technique, in two moments: before and after the crystallization of the material. The manikin tooth 14 was prepared for total crown. Then it was duplicated, in silicone, and there were obtained 16 replicas in polyurethane resin. Two groups were formed from the impression of the manikin through the direct and indirect scanning, For the Group 1 (IND/n = 08), the manikin was molded with stock tray, with addition silicone, by the simultaneous molding technique and modeling performed with gypsum stone type III and IV, totaling eight molds and plaster models. The models were sent to the laboratory for scanning on the scanner indirect. Dissilicate crowns were made of lithium milled. For the Group 2 (DIR/n = 08), the dummy was scanned by scanner directly. The eight images obtained were sent directly to the laboratory by the system program. Likewise, milled lithium dissilicate crowns were made. The marginal adaptation of the crowns was performed with the same ones on the respective polyurethane tooth, in the computerized microtomograph (&microCT), confocal laser microscope (CL) and through the replica technique (TR). Internal adaptation readings were performed using a &microCT and TR. The analyses were made before and after the crystallization of the crowns. The data showed normal distribution were analyzed by two factors ANOVA and the data did not show normal distribution were analyzed for U Mann-Whitney test for comparison among groups and by the Wilcoxon test for comparison before and after the crystallization . In relation to the axial adaptation, significant difference was verified only for Times (p = 0.017), with lower values after crystallization. For the internal adaptation was not observed difference between groups (p > 0.05) or Times studied (p > 0.05). For the vertical marginal adaptation difference to the IND group, with higher values after the crystallization analysis methodology-independent (&microCT p = 0.001;-p = 0.038 confocal). Already the measure presented divergent results horizontal marginal according to the methodology used. In &microCT, IND was greater than DIR (p = 0.003) and greater than after the crystallization (p < 0.001). In confocal IND less than DIR after the crystallization (p = 0.05), and DIR, before less than after the crystallization (p = 0.005). In total volume and marginal volume of space for cementation significant difference only to the DIR, with higher values after the crystallization (total volume - p = 0.025; marginal volume - p = 0.002). The results obtained can be concluded that there is contraction of the material after the crystallization, resulting in higher leakage evidenced by the increase of the total volume of the cementing space as a result of the settling difficulty the dissilicate Crown.
72

Prótese parcial fixa em pacientes com fissura labiopalatina / Fixed partial prosthesis in patients with cleft lip and palate

Mariana Gelmini 18 November 2011 (has links)
Introdução: A ausência do incisivo lateral superior é freqüente em indivíduos com fissuras que envolvem o rebordo alveolar. As próteses parciais fixas convencionais, apesar de se tratar de procedimento não conservativo devido ao desgaste dos dentes adjacentes à fissura, podem oferecer resultados funcional e estético satisfatórios. Objetivos: Avaliar a estética da prótese e do sorriso após reabilitação com prótese parcial fixa na área da fissura, avaliar clinicamente as condições biológicas do periodonto de proteção na área correspondente à prótese e analisar o grau de satisfação dos pacientes após tratamento. Material e Métodos: Foram selecionados 40 pacientes, de ambos os gêneros, com fissura transforame incisivo e pré-forame incisivo unilateral completa, reabilitados com prótese parcial fixa na área do incisivo lateral superior ausente. Esses foram fotografados, para posterior análise por três grupos de examinadores, que classificaram a estética das próteses como agradável, aceitável e desagradável. Questionários e escala analógica visual foram utilizados para avaliar o grau de satisfação dos pacientes. Para análise estatística foram obtidos valores médios, mediana e desvio padrão e utilizados coeficiente Kappa conforme caracterizado por Landis e Koch (1977), teste de Kruskal Wallis e coeficiente de Spearman, adotando-se nível de significância 5%. Resultados: A fissura transforame incisivo unilateral correspondeu a 62,5% dos casos. Não houve diferença estatisticamente significante entre os grupos de examinadores, que consideraram prótese esteticamente aceitável e a concordância interjuízes foi considerada de moderada a substancial. Para os pacientes, a estética da prótese foi considerada satisfatória para 65% e aceitável para 22,5%. Conclusão: A maioria dos casos clínicos foi considerada prótese esteticamente aceitável, sendo que as próteses devem ser melhoradas no que diz respeito à curvatura incisal e tamanho das coroas. A ausência de papila gengival e sua reposição artificial foram observadas na maioria dos casos clínicos. A maioria dos pacientes considerou a prótese satisfatória em relação à estética e também em relação à estética do sorriso; mais estudos tornam-se necessários para se alcançar excelência no tratamento dos pacientes com fissuras. / Introduction: The absence of the lateral incisor is frequent in individuals with clefts involving the alveolar crest. The conventional prosthesis fixed partial , despite the fact that isn´t a conservative procedure, may offer results functional and aesthetic satisfactory. Objectives: To evaluate the aesthetics of the prosthesis and the smile after rehabilitation with prosthesis fixed partial in the area of the cleft, to evaluate clinically the biological conditions of the periodontium of protection in the area corresponding to the prosthesis installed and analyze the degree of patient satisfaction after treatment. Material and Methods: The sample included 40 patients of both genders, with complete unilateral cleft lip and palate, rehabilitated with partial prosthesis sets in the area of the lateral incisor absent. These patients were photographed for later analysis by groups of examiners, the prostheses of the patients were classified as aesthetically pleasing, aesthetically acceptable and aesthetically unpleasant. Questionnaires and visual analog scale were used to assess the degree of satisfaction of the patients after treatment received. For the statistical analysis the average values, median and standard deviation was obtained and by the use Kappa coefficient in agreement with Landis and Koch (1977), Kruskal Wallis Test and Spearman coefficient, with a 5% significance level adopted. Results: The unilateral cleft lip and palate accounted for 62.5% of cases. There was no statistically significant difference between the groups of examiners, was identified in all the cases aesthetically acceptable prosthesis, and the agreement of interjudges was considered moderate to substancial. For patients, the treatment was satisfactory in 65% of the cases, while22.5% considered acceptable. Conclusion: Most clinical cases was considered aesthetically acceptable prostheses with the dentures should be improved with respect to the curvature and size of incisal crowns. The absence of gingival papilla and its artificial replacement were observed in most clinical cases. Most patients considered satisfactory prosthesis in relation to aesthetics and also in relation to aesthetics of the smile, but do not consider acceptable in relation to aesthetic of the prosthesis, more studies are needed to achieved excellence in the treatment gives patients.
73

Força de mordida em pacientes com fissura labiopalatina reabilitados com próteses parciais fixas sobre dentes naturais e implantes / BITE FORCE IN PATIENTS WITH REHABILITATED CLEFT LIP AND PALATE WITH PARTIALLY FIXED PROSTHESES ON NATURAL TEETH AND IMPLANTS

Rafael D'Aquino Tavano 31 July 2015 (has links)
As fissuras palatinas além de envolvem o osso alveolar podem promover a ausência do dente incisivo lateral ou apresenta-lo severamente comprometido. Nesses casos sua reabilitação poderá ser feita por próteses parciais fixas convencionais ou por prótese sobre implantes, geralmente após uma cirurgia de enxerto ósseo na região. Todavia além da estética, se faz necessário investigar sobre o potencial de força oclusal que essas reabilitações proporcionam. Assim, o propósito desse estudo foi avaliar a força máxima de mordida em indivíduos com fissura labiopalatina unilateral reabilitados com prótese parcial fixa convencional e sobre implantes e comparar esses resultados com o lado contralateral e com indivíduos sem fissura. A amostra foi constituída por 50 indivíduos, 25 pacientes com fissura (15 reabilitados com próteses parciais fixas convencionais e 10 sobre implantes) e 25 indivíduos sem fissura com dentes naturais. A força de mordida máxima foi mensurada por um único examinador utilizando o gnatodinamômetro, registrado nas regiões reabilitadas de incisivo lateral e canino, região de molares e incisivos centrais. Os valores médios obtidos, e a análise estatística com os testes t de Student e t de Student pareado permitiram observar que no mesmo indivíduo, a força de mordida do lado não afetado foi estatisticamente superior quando comparado com o lado da fissura reabilitado com prótese (p=0,005). O grupo reabilitado com prótese fixa convencional apresentou a força máxima de mordida estatisticamente igual ao grupo com prótese fixa sobre implante (p=0,781). Considerando os grupos experimental e controle na região de molares os resultados foram estatisticamente iguais (lado afetado p=0,082 e não afetado p=0,066). Na região de incisivo lateral e canino, o lado correspondente ao afetado no grupo-controle, apresentou força máxima de mordida estatisticamente maior que o grupo-experimental (p=0,004), enquanto no lado correspondente ao não afetado os resultados foram iguais. Na região de incisivos centrais o resultado médio do grupo-controle também foi estatisticamente maior que o experimental (p=0,005) / The cleft palate involving the alveolar bone may have the lateral incisor tooth missing or severely compromised. In such cases rehabilitation can be done through fixed dental prostheses or implant-supported fixed dental prostheses, generally after a bone graft surgery in the region. However, beyond aesthetics, it is necessary to investigate the potential for occlusal force that these rehabilitations provide. Thus, the purpose of this study was to evaluate the maximum bite force in subjects with unilateral cleft lip and palate rehabilitated with fixed dental prostheses or implantsupported fixed dental prostheses and compare the results with the contralateral side and with individuals without cleft. The sample consisted of 50 subjects, 25 patients with cleft (15 rehabilitated with fixed dental prostheses and 10 with implant-supported fixed dental prostheses) and 25 individuals without cleft and with natural teeth. The maximum bite force was measured by means of gnathodynamometer, registered in the rehabilitated lateral incisor and canine region, molars region and incisors regions by a single examiner. The obtained average values, and the statistical analysis with the Student t test and paired Student t test allowed to be observed that on the same individual the bite force on the side that was not affected was statistically superior when compared to the side of the rehabilitated cleft with prosthesis (p=0,005). The rehabilitated group with conventional prostheses presented maximum bite force statistically equal to the group with the implant-supported fixed dental prostheses (p=0,781). Considering the experimental and control groups on the molar regions, the results were statistically equal (affected side p=0,082 e non-affected p=0,066). The lateral incisor and canine region from the correspondent affected side on the control group presented maximum bite force statistically higher than the experimental group (p=0,004), on the non-affected side the results were the same. In the incisor region, the average result of the control group was also statistically higher than the experimental group (p=0,005)
74

Influência da inserção de fibras de Al2O3/GdAlO3 na resistência mecânica de monolayers e bilayers de cerâmicas odontológicas / Flexural strength of ceramic monolayers and bilayers bars reinforced by Al2O3/GdAlO3 fibers

Ricardo Sgura 20 May 2010 (has links)
O presente estudo avaliou a adição de fibras cerâmicas de 0,5mm de diâmetro de Al2O3/GdAlO3 obtidas por fusão a laser (método LHPG - laser heated pedestal growth) em porcelanas de cobertura dos sistemas In Ceram Alumina, In-Ceram 2000 Al Cubes e In-Ceram 2000 YZ Cubes para CEREC (VITA Zahnfabrik). Barras confeccionadas apenas com a porcelana de cobertura (VM7 ou VM9 - monolayers) ou constituídas por ambas a cerâmica da infraestrutura e porcelana de cobertura (bilayers) receberam as fibras dispostas longitudinalmente nas proporções de 10 ou 17% vol. Barras que não receberam fibras serviram como controle dos grupos. Os corpos-de-prova (CP) com fibras assim como os do grupo controle foram submetidos a um teste de flexão em três pontos. Foram calculadas as médias para a densidade e resistência à flexão dos CP, assim como para as fibras isoladamente. A tenacidade à fratura das fibras também foi mensurada. Em todos os casos a análise de variância de um fator e o teste de Tukey com 5% de significância foram aplicados. Microscopia eletrônica de varredura foi utilizada para caracterização microestrutural das fibras e para estudo fractográfico. Foram realizadas análises de difratometria por raio-x dos materiais cerâmicos nos estados pré e pós-sinterização, assim como foram determinados os coeficientes de expansão térmico-linear das porcelanas de cobertura por dilatometria. Os CP monolayers da porcelana VM9 contendo fibras apresentaram, após a sinterização, trincas e falhas, o que impediu a continuidade dos testes com os grupos de cerâmicas do sistema In-Ceram 2000 YZ Cubes. Os CP com fibras adicionadas à porcelana VM7 em 17% vol. apresentaram resistência à flexão aumentada em 43% comparados aos CP do grupo controle, sem fibras. Nos grupos bilayers as fibras propiciaram aumento apenas numérico da resistência à flexão do conjunto, porém de forma não significante. / This study evaluated the addition of 0.5mm of diameter Al2O3/GdAlO3 fibers obtained by LHPG (Laser Heated Pedestal Growth) to veneering porcelains of the following materials: porcelain monolayers: VM7 and VM9; Bilayers: In-Ceram Alumina + VM7, In-Ceram 2000 AL Cubes + VM7 and In-Ceram 2000 YZ Cubes for CEREC + VM9 (VITA Zahnfabrik). The specimens (bars) were composed by only the veneer porcelain (monolayer) or both the veneer and the framework (bilayer). The new ceramic composites contained longitudinal fibers in 10 or 17% vol. Specimens without fibers were used as control. A metallic device was developed for the standardization of the fibers position inside the specimens. The means of the fracture toughness, density and flexural strength of the developed fibers were calculated as well as the density and flexural strength of the composites. One way ANOVA and a Tukey test (5%) were applied. Characterizations of fiber/porcelain interface and fractographyc analysis were carried out after scanning electronic microscopy (SEM) of bars. X-ray difratometry and dilatometry were also performed. Vm9 porcelain showed incompatibility with the fibers, probably due to differences between the coefficients of thermal expansion of fibers and porcelain. VM7 monolayers with the addition of 17% of fibers in volume showed significantly higher resistance in relation to control. It was concluded that the inclusion of ceramic fibers of Al2O3/GdAlO3 to veneer porcelain improves its flexural strength.
75

Potencial inflamatório de duas técnicas para afastamento gengival utilizadas durante procedimentos protéticos / Inflammatory potential of two techniques used for gingival retraction during restorative procedures

SARMENTO, Hugo Ramalho 18 March 2013 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1 Dissertacao_hugo_ramalho.pdf: 1163967 bytes, checksum: 5735b7a46397cc9fceb1883f7a66141c (MD5) Previous issue date: 2013-03-18 / This study was composed by two phases that evaluated two gingival displacement (GD) techniques, conventional and cordless: 1- a in vitro study which assess cytoxicity/genotoxicity, and pH of AlCl3-based agents; and 2- a randomized clinical which evaluated the efficacy of these techniques. For in vitro phase, eluates were obtained by dilution of AlCl3-based into culture medium for 1h, 4h, and 24h. pH values were measured by digital pHmeter, cytotoxicity by MTT test and genotoxicity by Micronuclei test. A crossover, double-blind, randomized clinical trial was designed to evaluate clinical, immunologic and individual factors before and after GD by two techniques, conventional (gingival cord + astringent gel) and cordless (astringent-based paste). These factors were evaluated on incisors prepared for metal-ceramic dental crowns before, 1 day post-GD and 10 day post-GD. Interleukin 1&#946;, Interleukin 6 and Tumor Necrosis Factor &#945; concentrations were evaluated on gingival crevicular fluid collected before (control) and 1 day post-GD. In vitro data were analyzed by two-way ANOVA and Tukey test. Clinical data were analyzed by One-way Repeated Measures ANOVA and Tukey test (immunologic factor), Friedman test (periodontal parameters), and Fisher Exact or Qui-square test (pain, stress, and unpleasant flavor during GD). All test were realized considering p<0.05. Mean pH values were statistically higher for Viscostat than Expasyl. Both astringents were non-cytotoxic at 1h. Expasyl was more cytotoxic than Viscostat at 4h and 24h. Expasyl genotoxicity was not different from control group. Neither of the two evaluated techniques resulted in worse periodontal indices. Conventional technique was statistically more stressing than cordless, and similar considering pain and unpleasant taste. GD by the both 11 treatments evaluated led to statistically higher mean concentrations of the three interleukins evaluated. Conventional GD technique resulted in the highest interleukins levels. In vitro, AlCl3-based astringents presented acceptable biological activity with no genotoxic difference between Expasyl and control group. In vivo, cordless technique was less stressful and resulted in lower cytokines levels after GD / Este estudo foi composto por duas fases que avaliaram duas técnicas para afastamento gingival (AG), convencional e sem fio: 1- um estudo in vitro que avaliou acitotoxicidade/genotoxicidade, e o pH de agentes à base de AlCl3; e 2- um ensaio clínico randomizado que avaliou a eficácia destas técnicas. Na fase in vitro, eludatos foram obtidos pela diluição dos eluates agentes à base de AlCl3 em meio de cultura por 1h, 4h e 24h. Os valores de pH foram aferidos por pHmetro digital, citotoxicidade pelo teste MTT e genotoxicidade pelo teste do Micronúcleo. Um ensaio clínico randomizado, cruzado, duplo-cego foi concebido para avaliar fatores clínicos, imunológicos e individuais antes e após AG por duas técnicas, convencional (C: fio gengival + gel adstringente) e sem fio (SF: pasta à base de adstringente). Estes fatores foram avaliados em incisivos preparados para coroas metalo-cerâmicas antes, 1 dia e 10 dias após AG. As concentrações de Interleucina 1&#946;, Interleucina 6 e Fator de Necrose Tumoral &#945; foram avaliadas no fluido gengival crevicular coletado antes (controle) e 1 dia após AG. Os dados do estudo in vitro foram analisados por ANOVA 2-fatores e teste de Tukey. Os dados do ensaio clínico foram analiados por ANOVA para medidas repetidas e teste de Tukey (fator imunológico), teste de Friedman (parâmetros periodontais), e Exato de Fisher ou teste Qui-quadrado (dor, estresse e sabor desagradável). Todos os testes consideraram p<0.05. Os valores médios de pH foram estatísticamente superiores para C que para SF. As técnicas não foram citotóxicas no tempo de 1h. SF foi mais citotóxica que C em 4h e 24h. A genotoxicidade SF foi semelhante à do grupo controle. Nenhuma das técnicas avaliadas resultou em piora nos indices periodontais. Atétnica C foi mais estressante 9 que a SF, e semelhantes considerando dor e sabor desagradável. AG realizado por ambas as técnicas levou a maiores concentrações médias das três citocinas avaliadas. C resultou nos maiores níveis de interleucinas. In vitro, os adstringentes apresentaram atividade biológica aceitável, sem diferença na genotoxicidade entre as técnicas. In vivo, SF foi menos estressante e resultou em menores níveis de citocinas após AG
76

Distribuição de tensões em próteses parciais fixas posteriores livres de metal com retentores intracoronários: análise em elementos finitos / Stress distribution on metal-free posterior inlay-retained fixed partial dentures: finite element analysis

Marcelo Gomes da Silva 23 February 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Para reabilitar a ausência de um elemento dentário posterior, as próteses parciais fixas (PPF) com retentores intracoronários são uma alternativa aos implantes osseointegrados. O objetivo deste estudo foi avaliar a distribuição de tensões nessas próteses com três combinações de materiais: cerâmica de zircônia parcialmente estabilizada por ítria (ZPEI) revestida por cerâmica de fluorapatita (&#945;), cerâmica de dissilicato de lítio (&#946;) ou compósito fibrorreforçado (&#947;). Na composição &#945;, foram analisadas a presença ou ausência da cerâmica de revestimento na parede cervical das caixas proximais e três variações na área total da seção transversal dos conectores (4 mm de largura x 3,2, 4,2 ou 5,2 mm de altura). Em 8 modelos bidimensionais de elementos finitos, uma carga vertical de 500 N foi aplicada na fossa central do pôntico e as tensões principais máximas (tração) e mínimas (compressão) foram apontadas em MPa. Inicialmente foram avaliados os 6 modelos com PPF de ZPEI e suas variações. Os maiores valores das tensões de tração foram encontrados no terço cervical dos conectores. Quando presente nestas regiões, a cerâmica de revestimento recebeu tensões acima do limite de sua resistência à flexão. Na comparação entre os modelos sem cerâmica de revestimento na parede cervical das caixas proximais, mesmo aquele com conectores de 3,2 x 4 mm, cuja infraestrutura apresentava 2,5 x 3 mm, poderia ser recomendado para uso clínico. Altos valores de tensões de compressão foram registrados entre o terço oclusal e médio dos conectores, correspondente à união entre as cerâmicas, o que poderia ocasionar, devido à flexão, falhas adesivas. Posteriormente, o modelo de ZPEI com a cerâmica de fluorapatita ausente da parede cervical das caixas proximais e área total dos conectores de 4,2 x 4 mm foi comparado aos dois outros materiais com conectores de mesma área. Na PPF de dissilicato de lítio, os valores representaram uma provável violação do limite de sua resistência à flexão. A PPF de compósito fibrorreforçado apresentou tensões bem abaixo do limite de resistência à flexão de sua infraestrutura, mas, como no modelo de ZPEI, tensões compressivas se concentraram com alto valor entre o terço oclusal e médio dos conectores, local de união entre a resina composta e a infraestrutura de fibras. Os resultados mostraram que a cerâmica de dissilicato de lítio e a presença da cerâmica de fluorapatita na parede cervical das caixas proximais deveriam ser contraindicadas para a condição proposta. Parece viável uma área de conectores na infraestrutura de ZPEI com no mínimo 2,5 x 3 mm. A PPF de compósito fibrorreforçado apresenta resistência estrutural para a situação estudada, mas, como também aquelas compostas de ZPEI, aparenta ter como pontos fracos a adesão entre a infraestrutura e o material de cobertura e a própria resistência deste último. / Inlay-retained fixed partial dentures (IRFPD) are an alternative to osseointegrated implants to replace a single missing posterior tooth. The aim of this study was to evaluate the stress distribution within these prostheses with three material combinations: yttria-tetragonal zirconia polycrystal (Y-TZP) ceramic veneered with fluorapatite ceramic (&#945;), lithium-disilicate ceramic (&#946;) or fiber-reinforced composite (&#947;). In composition &#945;, an analysis was conducted on the presence or absence of the veneering ceramic on the cervical wall of the proximal boxes and three variations in the total area of the connectors cross-section (4 mm in width x 3.2, 4.2 or 5.2 mm in height). In 8 two-dimensional finite element models, a vertical load of 500 N was applied on the central fossa of the pontic. Maximum (tension) and minimum (compression) principal stresses were then shown in MPa. First, the 6 models with Y-TZP fixed partial dentures (FPD) and their variations were evaluated. The highest values of tensile stresses were found at the cervical third of the connectors. When present in these regions, the veneering ceramic received stresses beyond its flexural strength limit. In the comparison among models without veneering ceramic on the cervical wall of the proximal boxes, even the model with connectors of 3.2 x 4 mm, whose framework presented 2.5 x 3 mm, could be recommended for clinical use. High values of compressive stresses were recorded between the middle and occlusal thirds of the connectors, corresponding to the juncture of the ceramics. Owing to flexure, these stresses might lead to adhesive failures. Then, the Y-TZP model without fluorapatite ceramic on the cervical wall of the proximal boxes and total connector area of 4.2 x 4 mm was compared to the other two materials with connectors of the same area. For the lithium-disilicate FPD, the observed values would probably exceed its flexural strength limit. The fiber-reinforced composite FPD presented stresses far below the flexural strength limit of its framework, but, as observed in the Y-TZP model, high values of compressive stresses were concentrated between the middle and occlusal thirds of the connectors, where the juncture of the composite and the fiber framework is located. The results showed that the use of lithium-disilicate ceramics and the presence of fluorapatite ceramics on the cervical wall of the proximal boxes should be contraindicated for the condition proposed. A minimum of 2.5 x 3 mm for the connector area of the Y-TZP framework seems viable. The fiber-reinforced composite FPD presented structural resistance for the situation studied but, as was also the case of the Y-TZP fixed partial dentures, its weak points seem to be the adhesion between the framework and the veneering material, as well as the resistance of the veneering material itself.
77

Influência do método de aquecimento de revestimentos fosfatados sobre sua resistência à compressão e sobre a rugosidade de superfície e estabilidade dimensional de ligas de Ni-Cr e Ni-Cr-Ti

Zequetto, Michele Marques [UNESP] 24 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-24Bitstream added on 2014-06-13T20:06:15Z : No. of bitstreams: 1 zequetto_mm_dr_araca.pdf: 383469 bytes, checksum: 3fd20e10aa2c413edb650399efcff201 (MD5) / No processo de fundição pela cera perdida, os materiais envolvidos podem apresentar interações entre si e o de tempo despendido para se obter as estruturas metálicas é oneroso. Assim, o objetivo deste trabalho foi avaliar a influência da propriedade física de resistência à compressão de revestimentos fosfatados indicados para altas temperaturas de fundição, utilizando os métodos de aquecimento convencional (MAC) e rápido (MAR), e analisar a rugosidade de superfície e a alteração dimensional do produto final da fundição (a peça metálica) obtido com as ligas metálicas Ni-Cr (Verabond II) e Ni-Cr-Ti (Fit Cast Titanium). Os revestimentos estudados Castorit Super C, Castorit All Speed, Heat Shock e Micro Fine 1700 foram vazados em uma matriz de silicone que permitiu obter amostras com formato cilíndrico (n=200), medindo 10mm de diâmetro e 20mm de comprimento. A resistência (MPa) deles foi determinada à temperatura ambiente (resistência fria) após 15, 30 e 60 minutos de manipulação, e também imediatamente após serem submetidos aos métodos de aquecimento MAC e MAR (resistência de queima), por meio de uma máquina de ensaio universal, em velocidade de 0,05mm/min e carga de 150kgf. Após inclusão, aplicação dos métodos de aquecimento e fundição às amostras (n=120) para rugosidade de superfície (Ra-μm), foram avaliadas por um rugosímetro Mitutoyo Surftest SJ-401 com cut-off de 0,8mm e três repetições em cada amostra. A alteração dimensional foi determinada pela diferença entre os valores dimensionais da cera e da peça fundida (n=60) utilizando-se o software AutoCad2008. Os valores médios obtidos foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (p<0,05), apresentando os valores de resistência à compressão diferentes entre os revestimentos (Heat Shock os valores maiores) e entre os tempos de mensuração em relação... / In the lost wax casting procedure, the involved materials can present interactions among them and the time used to obtain the metallic structures is onerous. Thus, the purpose of this study was to evaluate the influence of the compressive strength physical property of phosphate-bonded investment materials indicated for high casting temperatures, utilizing conventional heating (CHM) and quick heating methods (QHM), and analyze the surface roughness and the dimensional accuracy of the final casting product (the metallic piece) obtained from Ni-Cr (Verabond II) and Ni-Cr-Ti (Fit Cast Titanium) metallic alloys. Castorit Super C, Castorit All Speed, Heat Shock and Micro Fine 1700 investment materials were poured into a silicone matrix in order to obtain cylindrical samples (n=200), measuring 10mm in diameter and 20mm in length. Their strength (MPa) was determined at room temperature (green strength) after 15, 30 and 60 minutes of manipulation, and also immediately after being submitted to the CHM and QHM heating methods (fired strength), by means of an universal testing machine at 0,05mm/min speed and 150kgf load. After investing, applying the heating methods and casting the samples (n=120) for surface roughness (Ra), the samples were evaluated with a Mitutoyo Surftest SJ-400 profilometer with 0,8mm cut-off, three times in each sample. The dimensional accuracy was determined by the difference among the dimensional values of the wax and of the metallic piece (n=60) through the software AutoCad2008. The mean values obtained were submitted to ANOVA and Tukey tests (p <0.05), and the results showed that the values of compressive strength were different among the investment materials (Heat Shock presenting the highest values) and among the analysis times with a direct relation of time and strength increase, but there was no difference between CHM and QHM. Moreover, it was observed no differences... (Complete abstract click electronic access below)
78

Distribuição de tensões em próteses parciais fixas posteriores livres de metal com retentores intracoronários: análise em elementos finitos / Stress distribution on metal-free posterior inlay-retained fixed partial dentures: finite element analysis

Marcelo Gomes da Silva 23 February 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Para reabilitar a ausência de um elemento dentário posterior, as próteses parciais fixas (PPF) com retentores intracoronários são uma alternativa aos implantes osseointegrados. O objetivo deste estudo foi avaliar a distribuição de tensões nessas próteses com três combinações de materiais: cerâmica de zircônia parcialmente estabilizada por ítria (ZPEI) revestida por cerâmica de fluorapatita (&#945;), cerâmica de dissilicato de lítio (&#946;) ou compósito fibrorreforçado (&#947;). Na composição &#945;, foram analisadas a presença ou ausência da cerâmica de revestimento na parede cervical das caixas proximais e três variações na área total da seção transversal dos conectores (4 mm de largura x 3,2, 4,2 ou 5,2 mm de altura). Em 8 modelos bidimensionais de elementos finitos, uma carga vertical de 500 N foi aplicada na fossa central do pôntico e as tensões principais máximas (tração) e mínimas (compressão) foram apontadas em MPa. Inicialmente foram avaliados os 6 modelos com PPF de ZPEI e suas variações. Os maiores valores das tensões de tração foram encontrados no terço cervical dos conectores. Quando presente nestas regiões, a cerâmica de revestimento recebeu tensões acima do limite de sua resistência à flexão. Na comparação entre os modelos sem cerâmica de revestimento na parede cervical das caixas proximais, mesmo aquele com conectores de 3,2 x 4 mm, cuja infraestrutura apresentava 2,5 x 3 mm, poderia ser recomendado para uso clínico. Altos valores de tensões de compressão foram registrados entre o terço oclusal e médio dos conectores, correspondente à união entre as cerâmicas, o que poderia ocasionar, devido à flexão, falhas adesivas. Posteriormente, o modelo de ZPEI com a cerâmica de fluorapatita ausente da parede cervical das caixas proximais e área total dos conectores de 4,2 x 4 mm foi comparado aos dois outros materiais com conectores de mesma área. Na PPF de dissilicato de lítio, os valores representaram uma provável violação do limite de sua resistência à flexão. A PPF de compósito fibrorreforçado apresentou tensões bem abaixo do limite de resistência à flexão de sua infraestrutura, mas, como no modelo de ZPEI, tensões compressivas se concentraram com alto valor entre o terço oclusal e médio dos conectores, local de união entre a resina composta e a infraestrutura de fibras. Os resultados mostraram que a cerâmica de dissilicato de lítio e a presença da cerâmica de fluorapatita na parede cervical das caixas proximais deveriam ser contraindicadas para a condição proposta. Parece viável uma área de conectores na infraestrutura de ZPEI com no mínimo 2,5 x 3 mm. A PPF de compósito fibrorreforçado apresenta resistência estrutural para a situação estudada, mas, como também aquelas compostas de ZPEI, aparenta ter como pontos fracos a adesão entre a infraestrutura e o material de cobertura e a própria resistência deste último. / Inlay-retained fixed partial dentures (IRFPD) are an alternative to osseointegrated implants to replace a single missing posterior tooth. The aim of this study was to evaluate the stress distribution within these prostheses with three material combinations: yttria-tetragonal zirconia polycrystal (Y-TZP) ceramic veneered with fluorapatite ceramic (&#945;), lithium-disilicate ceramic (&#946;) or fiber-reinforced composite (&#947;). In composition &#945;, an analysis was conducted on the presence or absence of the veneering ceramic on the cervical wall of the proximal boxes and three variations in the total area of the connectors cross-section (4 mm in width x 3.2, 4.2 or 5.2 mm in height). In 8 two-dimensional finite element models, a vertical load of 500 N was applied on the central fossa of the pontic. Maximum (tension) and minimum (compression) principal stresses were then shown in MPa. First, the 6 models with Y-TZP fixed partial dentures (FPD) and their variations were evaluated. The highest values of tensile stresses were found at the cervical third of the connectors. When present in these regions, the veneering ceramic received stresses beyond its flexural strength limit. In the comparison among models without veneering ceramic on the cervical wall of the proximal boxes, even the model with connectors of 3.2 x 4 mm, whose framework presented 2.5 x 3 mm, could be recommended for clinical use. High values of compressive stresses were recorded between the middle and occlusal thirds of the connectors, corresponding to the juncture of the ceramics. Owing to flexure, these stresses might lead to adhesive failures. Then, the Y-TZP model without fluorapatite ceramic on the cervical wall of the proximal boxes and total connector area of 4.2 x 4 mm was compared to the other two materials with connectors of the same area. For the lithium-disilicate FPD, the observed values would probably exceed its flexural strength limit. The fiber-reinforced composite FPD presented stresses far below the flexural strength limit of its framework, but, as observed in the Y-TZP model, high values of compressive stresses were concentrated between the middle and occlusal thirds of the connectors, where the juncture of the composite and the fiber framework is located. The results showed that the use of lithium-disilicate ceramics and the presence of fluorapatite ceramics on the cervical wall of the proximal boxes should be contraindicated for the condition proposed. A minimum of 2.5 x 3 mm for the connector area of the Y-TZP framework seems viable. The fiber-reinforced composite FPD presented structural resistance for the situation studied but, as was also the case of the Y-TZP fixed partial dentures, its weak points seem to be the adhesion between the framework and the veneering material, as well as the resistance of the veneering material itself.

Page generated in 0.0754 seconds