• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 55
  • 55
  • 55
  • 42
  • 39
  • 36
  • 27
  • 13
  • 12
  • 12
  • 12
  • 11
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da eficiência e capacidade mastigatória em pacientes com fissura labiopalatina reabilitados com prótese de recobrimento / Evaluation of chewing ability and efficiency of patients with cleft lip and palate rehabilitated with prosthesis overlay

Tavano, Rafael D'Aquino 15 April 2011 (has links)
Objetivou-se com este trabalho avaliar a capacidade e eficiência mastigatória de 37 pacientes com fissuras labiopalatinas, matriculados no Hospital de Anomalias Craniofaciais, Universidade de São Paulo (HRAC-USP) e 20 indivíduos não fissurados. O grupo 1 foi composto por 20 pacientes com fissura labiopalatina e dentição natural até pelo menos o 1º molar nos dois arcos dentários. O grupo 2 foi de 17 pacientes com fissura labiopalatina envolvendo rebordo, arco superior atrésico e com prótese parcial removível de recobrimento. Este grupo foi dividido nas condições sem a prótese (grupo 2a) e com a prótese (grupo 2b). O grupo 3 considerado grupo controle, foi formado por 20 indivíduos sem fissura, com dentição natural até pelo menos o 1º molar nos dois arcos dentários. Para a avaliação da capacidade mastigatória utilizou-se questionário padronizado, baseado na literatura, onde um único examinador limitou-se a explica-lo o questionário e não induziu as respostas. Para análise da eficiência mastigatória foram utilizadas amêndoas como alimento teste e sistema de tamises com peneiras e orifícios diferentes. Os resultados para a avaliação da capacidade e eficiência mastigatória indicaram que não houve diferença estatisticamente significante entre os grupos com fissura e com dentição natural (grupo 1 ) e grupo controle, sem fissura e dentição natural (grupo 3 ). Todavia, estes dois grupos apresentaram resultados melhores que o grupo com fissura e prótese parcial removível de recobrimento. Para os indivíduos com fissura e com prótese (grupo 2), a eficiência mastigatória foi melhor na condição com a prótese (grupo 2b) do que na condição sem a prótese grupo 2a). / This study aimed at evaluating the chewing ability and efficiency of 37 patients with cleft lip and palate attending the HRAC-USP and 20 individuals without clefts. Group1 comprised 20 patients with clefts presenting natural dentition at least up to the first molar in both dental arches. Group 2 was composed of 17 patients with clefts wearing removable partial dentures in at least one dental arch. This group was subdivided in group 2a comprised patients with clefts and without removable partial denture and group 2b, comprised patients with clefts and with removable partial denture. Group 3 (control) included 20 individuals without clefts presenting natural dentition at least up to the first molar in both dental arches. Evaluation of the chewing ability was performed by application of a literature-based standardized questionnaire in which only one examiner explained the questions and did not induce the responses. Analysis of chewing efficiency was conducted by utilization of almonds as test food and a system of sieves with different sizes and orifices. There was no statistically significant difference between groups 1 and 3 in relation to the chewing ability, but when compared groups 2b and 3, and groups 1 and 2b, there was statistically significant difference. Concerning evaluation of chewing efficiency, the individuals without clefts presented similar (statistically equal) outcomes compared to patients with clefts with natural dentition up to the first molar, with statistically better results when compared to those observed for patients with clefts wearing removable partial dentures, who were tested both with and without the prostheses. Patients with clefts with natural teeth presented better outcomes as patients wearing removable dentures either with or without their dentures in position. Comparison within the group of patients with clefts wearing removable partial dentures revealed that their chewing efficiency was statistically better when their dentures were in position.
12

Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper arch

Bueno Junior, Eliseu Antonio 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.
13

Análise fotoelástica das cargas aplicadas em próteses parciais removíveis nas grandes perdas de maxila / Photoelastic analysis of the loads applied to removable partial dentures in large ressections of maxilla

Carvalho, Giorgia Borges de 12 December 2012 (has links)
Este trabalho teve a finalidade de avaliar pela técnica fotoelástica, o efeito que a prótese parcial removível teria, em aliviar as tensões sobre as raízes dos dentes. Para tanto preparamos um modelo com três tipos de desenhos de próteses parciais removíveis, simulando uma reabilitação nas grandes perdas de maxila. Todos os modelos de desenhos apresentaram planos guias em incisivo central e segundo molar, e se diferenciaram da seguinte forma: modelo 01, grampo circunferencial simples em canino, grampo gêmeo entre primeiro e segundo pré-molar e grampo gêmeo entre primeiro e segundo molar; modelo 02, utilizamos os mesmos grampos colocados no modelo 01 incluindo neste modelo um recobrimento palatino, modelo 03, grampo gêmeo entre canino e primeiro pré-molar, grampo gêmeo entre segundo pré-molar e primeiro molar e grampo circunferencial simples em mesial de segundo molar. Foram aplicadas cargas verticais de 10 kg, 15 kg e 20 kg em canino, segundo pré-molar e primeiro molar. Os resultados permitiram concluir que: Os planos guia comprovaram sua efetividade através do contato pleno nos dentes preparados para o seu assentamento. O recobrimento palatino não amenizou as cargas nas raízes dos dentes. Os grampos gêmeos, colocados em uma posição mais anterior, indicam uma distribuição melhor das tensões. Os grampos circunferenciais simples, colocados mais posteriormente, indicam uma melhor distribuição das tensões. Os modelos 01 e 02 apresentaram maiores tensões em incisivo central comparados com o modelo 03. O modelo 03 foi o que melhor distribuiu as cargas de forma mais equilibrada mostrando tensões de menor magnitude. Os melhores modelos de próteses parciais removíveis, pela perspectiva de transferência de tensão foram primeiramente o modelo 03, depois o modelo 01 e por fim o modelo 02. A mudança do desenho da PPR alterou a distribuição das tensões nos dentes dos modelos avaliados. / This study aimed to evaluate by the photoelastic technique, the effect that the partial denture would have to reduce tensions on the roots of teeth. For this reason, was prepared a model with three types of removable partial dentures designs, simulating rehabilitations in large ressections of maxilla. All models presents guide-planes on central incisor and second molar, and was differentiated as follows: Model 01, simple circumferential clasp in canine, twin clasps between first and second premolar and twin clasps between first and second molar; model 02, we use the same clasps as model 01 only including a palatal covering in this model, model 03, twin clasps between canine and first premolar, twin clasps between second premolar and first molar and simple circumferential clasp at mesial of second molar. Were applied vertical loads of 10 kg, 15 kg and 20 kg in canine, second premolar and first molar. The results showed that: The guide-planes proved its effectiveness through full contact in the teeth prepared for their settlement. The palatal covering failed to alleviate the stress on the roots of teeth. Twins clasps, placed in a more anterior position, indicating a better distribution of stresses. Simple circunferencial clasp, placed in a more posterior position indicating a better distribution of stresses. Models 01 and 02 had higher tensions in central incisor compared with the model 03. The Model 03 was the best considering equilibrated load distribution showing stress of lesser magnitude. The best models of removable partial dentures, from the perspective of stress transfer were first model 03, followed by the model 01 and then finally the model 02. The change os design of RPD changed the distributions os tensions in teeth of evaluated models.
14

Avaliação dos dentes pilares e não pilares de indivíduos com fissura labiopalatina reabilitados com prótese parcial removível / Evaluation of abutment teeth and not abutment teeth of individuals with cleft palate rehabilitated with removable partial dentures

Catalani, Danilo Tomazini 05 April 2013 (has links)
Objetivos: Neste estudo objetivou-se avaliar e comparar a condição periodontal de dentes pilares e não pilares de indivíduos com fissura labiopalatina reabilitados com prótese parcial removível instalada. Material e métodos: Pilares de 45 pacientes com fissuras labiopalatinas, de ambos os gêneros que utilizam prótese parcial removível, matriculados no Hospital de Reabilitação de Anomalias Craniofaciais, Universidade de São Paulo (HRAC-USP), com idade variando de 25 a 72 anos. Foram excluídos da amostra os indivíduos com alterações sistêmicas, doenças neurológicas, que tenham realizado tratamento periodontal prévio nos últimos seis meses, fumantes, gestantes, etílicos, usuários de drogas, que estavam fazendo uso de antidepressivos, antiinflamatórios, anticonvulsivantes, bloqueadores de cálcio ou qualquer fármaco que pudesse interferir nos resultados deste estudo. Os parâmetros clínicos avaliados por um único avaliador foram: medida de profundidade de sondagem, nível de inserção clínico, índice gengival, índice de placa, recessão gengival, quantidade de mucosa ceratinizada, com sonda periodontal, além das condições de higiene da prótese, classificação da área desdentada, classificação do tipo de grampo e foi aplicado o questionário de qualidade de vida. Resultados: Não houve diferença estatisticamente significante entre os dentes pilares e não pilares com exceção do nível de inserção clínico e profundidade de sondagem. As próteses de classe III foram as mais frequentes. Os escores 2 e 3 foram os mais frequentes dos índices de placa e Tarbet. O tipo de prótese, segundo a classificação de Kennedy não influenciou o OHIP-14. Os escores mais frequentes do OHIP-14 foram 0 e 1 . Conclusões: Os dentes pilares e não pilares das próteses parciais removíveis de indivíduos com fissura labiopalatina não apresentaram diferenças significativas nos parâmetros clínicos avaliados com exceção do nível de inserção clínico e profundidade de sondagem, aceitando-se parcialmente a hipótese nula. O tipo de grampo a classificação das próteses não tiveram influência na qualidade de vida. Os pacientes necessitam de melhor orientação de higiene oral já que os índices de placa e de Tarbet apresentaram médios a altos escores. / Purposes: This study aimed to evaluate and compare the periodontal status of abutment teeth and not abutment teeth of individuals with cleft palate rehabilitated with removable partial denture installed. Materials and Methods: abutment teeth of 45 patients with cleft lip and palate, of both genders using removable partial dentures, enrolled at the Hospital for Rehabilitation of Craniofacial Anomalies, University of São Paulo (HRAC-USP), aged 25-72 years. Were excluded from the sample individuals with systemic conditions, neurological diseases, who have made previous periodontal treatment in the last six months, smokers, pregnant women, ethyl, drug users, who were taking antidepressants, antiinflammatories, anticonvulsants, calcium blockers or any drug that could interfere with the results of this study. The clinical parameters assessed by a single evaluator were measured probing depth, clinical attachment level, gingival index, plaque index, gingival recession, amount of keratinized mucosa, periodontal probe, and the hygiene of the prosthesis, the classification edentulous area, type classification clamp was applied and the quality of life questionnaire. Results: There was no statistically significant difference between the abutment teeth and not abutment teeth except clinical the attachment level and probing depth. The prostheses of class III were the most frequent. The scores 2 and 3 were the most frequent plaque index and Tarbet. The type of prosthesis, according to the classification of Kennedy did not influence the OHIP-14. Scores Frequently OHIP-14 were 0 and 1. Conclusions: The abutment teeth and not abutment teeth of removable partial dentures for individuals with cleft palate showed no significant differences in clinical parameters evaluated with the exception of clinical attachment level and probing depth, partially accepting the null hypothesis. The type of staple sorting prosthesis did not influence the quality of life. Patients need better oral hygiene care, since the plaque index and Tarbet had medium to high scores.
15

\"Avaliação comparativa por meio de eletromiografia de superfície do padrão de comportamento dos músculos masseter e temporal em pacientes parcialmente edentados antes e após a reabilitação com próteses parciais removíveis\" / Comparative evaluation through surface electromyograph of the temporal and masseter muscles behaviour pattern in partially edentulous patients before and after removable partial denture rehabilitation.

Navarro, Jéssica Nery 15 March 2007 (has links)
Como um procedimento de avaliação, a eletromiografia clínica de superfície, envolve a detecção e o registro de potenciais elétricos de fibras musculares esqueléticas, fornecendo um instrumento útil para documentar o papel do músculo na atividade física e para avaliar a integridade do sistema neuromuscular. Tendo em vista sua utilidade, somada a relatos na literatura da existência de comprometimento muscular nos pacientes parcialmente edentados, e ainda a inexistência de relatos literários sobre a modificação do padrão de atividade muscular nos pacientes parcialmente edentados após a reabilitação; nosso objetivo nessa pesquisa foi registrar e comparar eletromiograficamente, as atividades musculares, de pacientes classe I e II de Kennedy (edentados posteriores uni ou bilaterais) em um dos arcos, antes e de 2 a 3 semanas após a instalação de próteses parciais removíveis (PPRs) e assim verificar o comportamento dos músculos masseter direito e esquerdo e temporal (feixe anterior) direito e esquerdo nessas duas situações durante a execução de abertura máxima, contração isométrica máxima voluntária (CIMV), repouso e mastigação. Após a realização desse estudo, pudemos concluir que a utilização das PPRs, restabelece os contatos oclusais posteriores perdidos e desta forma, modifica para melhor as atividades eletromiográficas da musculatura em questão (masseter e temporal). Os pacientes monitorados apresentaram um aumento extremamente significante (p < 0,0001) da eficiência da musculatura estudada durante a mastigação e ainda uma diminuição, também extremamente significante (p < 0,0001), da atividade elétrica dos masseteres e temporais durante o período de repouso e na execução da abertura máxima. / As an evaluation proceeding, the clinical surface electromyograph, envolves the detection and the registration of electric potential of muscular skinny fibers, being an useful instrument to verify the hole of the muscle in the physical activity and to evaluate the neuromuscular system condition. Keeping in mind its usefulness, added up to literature reports of the existence of muscular compromising in the partially edentulous patients, and also, the non-existence of literary articles reporting modification of muscular activity pattern in partially edentulous patients after the oral rehabilitation; our purpose in doing this research is register and compare by electromyographic study, the muscular activities, of Kennedy class I or II patients (uni or bilateral partially edentulous) in one of the arches, before and after the installation of removable partial dentures (RPDs) and also, check the behaviour of the elevator muscles: right and left masseter and right and left anterior temporal in these two situations during the execution of maximal opening, maximal isometric voluntary contraction (MIVC), rest and mastication. At the end of this study, we could conclude that the use of the RPDs, restores the oclusal contats (previously lost) and in this way, modifies the electromyographic activities of the evaluated muscles (masseter and anterior temporal). The monitored patients presented an increase extremely significant (p < 0,0001) of the musculature efficiency during the mastication and also, an extremely significant reduction (p <0,0001), of the electric activity of the four muscles during the period of rest and during the maximal opening movement.
16

Avaliação da influência da força de mordida na prótese parcial removível classe I mandibular associada ao implante osseointegrado, pelo método dos elementos finitos /

Lucas, Liliana Vicente Melo de. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Resumo: A associação entre as próteses parciais removíveis e os implantes osseointegrados é, ainda, uma opção de tratamento muito pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), localizado na região posterior do rebordo alveolar desdentado, atuando como suporte para a base da prótese. Para tanto, foram criados três modelos, os quais, em corte sagital, representam: modelo A (MA) - hemiarco contendo o dente natural 33 somente e o A rebordo desdentado distal; modelo B (MB) - semelhante ao MA, com uma PPREL convencional substituindo os dentes ausentes; modelo C (MC) - semelhante ao anterior, com um implante na região posterior do rebordo, sob a base da prótese. Com o auxílio do programa de elementos finitos ANSYS 5.4, os modelos foram carregados com forças verticais e oblíquas de 45º, tanto no sentido de mesial para distal como no sentido inverso, de magnitude de 50 N, em cada ponta de cúspide. A análise dos mapas de tensões permitiu concluir que: 1) a tendência de deslocamento no modelo com a PPR apoiada sobre implante é menor que no modelo com a prótese somente; 2) as forças oblíquas de 45º promovem uma tendência de deslocamento e valores de tensão maiores que a força vertical; 3) a força oblíqua de 45º, no sentido de mesial para distal, gera valores de tensão menores que a de distal para mesial e 4) a presença do implante osseointegrado, sob a base da prótese, promove alívio do dente suporte. / Abstract: The association among the removable partial dentures and the osseointegrated implants is still a non very explored option of treatment in the modern prosthetic dentistry. Because of this, the objective of this study is to evaluate, using the two-dimensional finite element analysis, the tension distribution in the support structures of the distal extension removable partial denture (RPD) associated with a 10.0 x 3.75 mm osseointegrated implant (Branemark System), located in the posterior area of the toothless alveolar edge, acting as support for the prosthesis base. Then, three plane strain models were created, represented in sagital cut: Model A (MA) - hemiarc containing the natural tooth 33 and the toothless alveolar edge; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with an implant in the posterior area of the edge, under the denture base. With the aid of the finite element program ANSYS 5.4, the models were loaded with vertical and 45º inclined forces, in both mesial and distal sides, with 50 N, on each peak point. The analysis of the tensions map allowed to conclude that: 1) the displacement tendency in the model with the RPD supported by the implant is smaller than the model with prosthesis only; 2) the oblique forces of 45º promote a displacement tendency and larger tension values than the vertical force; 3) the mesial to distal 45º oblique force generates smaller tension values than the one of distal to mesial and 4) the presence of the osseointegrated implant, under the denture base, promotes relief to the support tooth. / Mestre
17

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular : análise da distribuição das tensões pelo método da fotoelasticidade /

Ferraço, Renato. January 2009 (has links)
Resumo: A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture - fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) "I" bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) "I" bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Stefan Fiuza de Carvalho Dekon / Banca: Marcelo Coelho Goiato / Banca: Fellippo Ramos Verri / Mestre
18

Ruídos articulares em pacientes parcialmente desdentados (classe I ou II de Kennedy), antes e após a reposição dental com prótese parcial removível: avaliação através da eletrovibratografia

Baleeiro, Renata Porfíria [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:35:12Z : No. of bitstreams: 1 baleeiro_rp_me_araca.pdf: 915852 bytes, checksum: eda0ee966910bd8f3eec26386a5fc0fa (MD5) / Universidade Estadual Paulista (UNESP) / As alterações no aparelho estomatognático parecem se originar do desequilíbrio ortopédico da mandíbula. Uma das causas desse desequilibro é a ausência do suporte oclusal que poderia conduzir a uma posição côndilo-disco inadequada na fossa mandibular, diminuição da força dos músculos elevadores da mandíbula, lubrificação deficiente. Essas mudanças podem levar ao desalojamento do disco articular e, conseqüentemente, ao aparecimento de vibrações articulares. Dessa forma, este estudo busca identificar e quantificar a presença de vibrações por meio da eletrovibratografia em articulações temporomandibulares de pacientes Classe I e/ou II de Kennedy, no momento da consulta, um ano e dois anos após o tratamento oclusal. Os resultados indicaram que as vibrações articulares foram mais freqüentes no final da abertura e do fechamento bucal. Entretanto, as vibrações diminuíram no primeiro e no segundo ano, sendo que somente após dois anos a redução foi estatisticamente significante. A redução da vibração articular verificada é sugestiva de que o suporte molar evita o desalojamento do disco e permite um fortalecimento muscular. / The alterations in stomatognathic apparatus can be originate by orthopedical disbalance of the jaw. One of the causes of orthopedical disbalance is the absence of the occlusal support that could lead to a inadequate condyle-disk position related to mandibular fossa, weakness of mandibular elevators muscles, and joints temporomandibulars deficient lubrication. These alterations can contribute to displacement of the articular disk and consequently the forthcoming of articular vibrations. This aim of this study is to identify and quantify the presence of vibrations through the electrovibratography in temporomandibular joint of Kennedy class I and/or II patient, at the initial appointment, one year and two years after the occlusal treatment. The results indicated that the articular vibrations were more frequent at the end of the opening and buccal closing. However, the vibrations decreased in the first and second year. After second years the differences were statistically significant. The reduction of the articular vibration verified is suggestive that the support molar avoids the displacement of the disk and it allows a muscular invigoration.
19

Estudo comparativo in vitro da resistência à remoção de grampos circunferenciais aplicados sobre dentes íntegros e restaurados com resina composta

Melo Filho, Antonio Braulino de [UNESP] 30 June 1994 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:56Z (GMT). No. of bitstreams: 0 Previous issue date: 1994-06-30. Added 1 bitstream(s) on 2015-12-10T14:29:10Z : No. of bitstreams: 1 000026434.pdf: 4352939 bytes, checksum: f59dc1edfd8a91ab4f0abc5ee063d699 (MD5) / Foi realizado um estudo experimental in vitro para investigar o comportamento da força necessária para o deslocamento de grampos circunferenciais de P.P.R. em dois grupos de corpos de prova: 1 com regime de trabalho do terminal retentivo sobre esmalte 2 com regime de trabalho do terminal retentivo sobre resina composta Para tal finalidade foi idealizado um dispositivo, construído a partir de uma máquina de costura de marca Elgin que tinha por objetivo simular repetidamente o movimento de introdução e remoção de grampos circunferenciais sobre os corpos de prova. O dispositivo contava ainda com uma plataforma para fixar os corpos de prova e permitir aferições, um contador de ciclos e um dinamometro. Os corpos de prova foram obtidos a partir da inclusão em gesso de dentes naturais extraídos, íntegros, do grupo dos molares, cujas áreas retentivas eram em esmalte natural ou construídas artificialmente, por adição de resina composta. Os grampos foram obtidos a partir de esculturas com resina acrílica e cera e fundidos em liga de cobalto cromo. A resina composta usada foi de última geração, do tipo monomodal, fotopolimerizável e retida no esmalte através de ataque ácido. Os testes foram realizados em meio aquoso, estabelecendo-se para cada corpo de prova cinco mil ciclos. Foram feitas verificações a cada cem ciclos até dois mil e a cada duzentos ciclos até o total de cinco mil. Os resultados mostraram que as variações na quantidade de força necessária para remover os grampos dos corpos de prova durante todo o período dos ensaios foi desprezível, sem significância, tanto para aqueles com áreas retentivas em esmalte como naqueles com áreas retentívas artificialmente feitas com resina composta / An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
20

Prótese parcial removível de extremidade livre associada a um implante osseointegrado : influência do ligamento periodontal na distribuição interna das tensões /

Archangelo, Carlos Marcelo January 2005 (has links)
Resumo: Em função da adoção de hipóteses simplificadoras nos estudos através do método dos elementos finitos (MEF), os dados sobre a menor solicitação das estruturas de suporte na associação da prótese parcial removível de extremidade livre (PPREL) com um implante osseointegrado são inconclusivos. Assim, foi objetivo do presente estudo avaliar, através do MEF bidimensional, a distribuição interna das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado, em função da reprodução homogênea e não-homogênea do ligamento periodontal (LP). Para isso, 6 modelos (M) foram criados no programa AutoCAD 2005 (Autodesk Inc.; USA), representando: MA - hemiarco contendo somente o dente 33 e o rebordo desdentado para distal; MB - semelhante ao A, com uma PPREL substituindo os dentes ausentes; MC - semelhante ao B, com um implante (Sistema Bränemark - 3,75 mm x 10,0 mm) na região retromolar suportando a base da prótese; MD, ME e MF semelhantes aos modelos A, B e C, respectivamente, com exceção do LP, que foi modelado de forma não-homogênea, com a representação de 4 conjuntos de fibras: fibras da crista, horizontais, oblíquas e apicais. Após isso, os modelos foram exportados para o programa de elementos finitos ANSYS 8.0, e carregados com forças estritamente verticais de 50N em cada ponta de cúspide, fracionadas em 5 pontos de 10N. Os mapas gerais de tensões evidenciaram máxima e mínima concentração de tensões de (em MPa): MA (58,976 e 0,0045); MB (77,863 e 0,0551); MC (207,195 e 0,0057); MD (110,33 e 0,0137); ME (191,36 e 0,0044) e MF (326,60 e 0,0076), com deslocamento máximo de (mm): MA (0,0631); MB (0,1263); MC (0,1142); MD (0,2709); ME (0,1960) e MF (0,2019). (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The application of many hypotheses in a finite element analysis (FEA) has been critical to obtain precise results in the removable partial denture treatment associated with an osseointegrated implant. In view of that, the purpose of the present study was to evaluated, through 2-D finite element analysis, the stress distribution in the support structures of a free-end saddle removable partial denture (RPD) associated with an osseointegrated implant, in function of the homogenous and non-homogenous condition for the periodontal ligament. For this, 6 models (M) were created in the AutoCAD software (Autodesk Inc.; USA), representing: MA - hemiarch contain only the natural tooth (33) and edentulous space in the posterior region; MB - similar to MA, with an RPD replacing the absent teeth; MC - similar to MB, with an osseointegrated implant (Branemark System - 3.75 x 10.00 mm) positioned in a posterior region in order to support the RPD base; MD, ME and MF - identical to MA, MB and MC, respectively; however, in these models, the periodontal ligament was considered an non-homogenous structure by the incorporation of four fibers groups in a sagital plane: alveolar crest fibers, horizontals, oblique, and apical fibers. After this, the models were exported to the finite element program (ANSYS 8.0) and loaded with verticals forces (50N) in each cusp. The results showed maximum and minimum stress (MPa): MA (58.976 and 0.0045); MB (77.863 and 0.0551); MC (207.195 and 0.0057); MD (110.33 and 0.0137); ME (191.36 and 0.0044) and MF (326.60 and 0.0076). The maximum displacement (mm) was: MA (0.0631); MB (0.1263); MC (0.1142); MD (0.2709); ME (0.2019) and MF (0.2019). (Complete abstract click eletronic address below) / Orientador: Eduardo Passos Rocha / Coorientador: João Antônio Pereira / Banca: Eduardo Piza Pellizzer / Banca: Wellington Cardoso Bonachela / Banca: Eduardo Passos Rocha / Mestre

Page generated in 0.4831 seconds