• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • 1
  • Tagged with
  • 54
  • 54
  • 36
  • 33
  • 16
  • 13
  • 12
  • 11
  • 11
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Influência dos diferentes tratamentos de superfície em discos de titânio comercialmente puro sobre a formação e aderência do biofilme inicial: estudo in situ / Influence of the different surface treatments in the commercially pure titanium discs in formation and adherence of the initial biofilm: an in situ study

Cyntia Ferreira Ribeiro 26 June 2013 (has links)
Hipótese do Estudo: O presente estudo hipotetizou que superfícies tratadas de discos de titânio comercialmente puro (Ti c.p.) são mais susceptíveis a aderência bacteriana que as superfícies lisas. Objetivo: O objetivo deste trabalho foi avaliar, in situ, a aderência bacteriana em discos de Ti c.p. submetidos a dois diferentes tratamentos de superfície: duplo ataque ácido e anodização. Metodologia: Sessenta corpos-de-prova de Ti c.p. foram divididos em três grupos: Grupo 1 - discos de Ti c.p. liso (grupo controle); Grupo 2 - discos de Ti c.p. com superfície duplamente condicionada com ácido (Master Pours Implant, Conexão Sistemas Prótese LTDA, SP., Brasil) e o Grupo 3 - discos de Ti c.p. submetidos à irradiação laser (Vulcano Actives, Conexão Sistemas Prótese LTDA, SP., Brasil). Inicialmente foi avaliada a rugosidade superficial (Ra) de todos os corpos-de-prova. Para a avaliação in situ, foram confeccionadas dez moldeiras individuais e em cada uma delas fixados seis discos de titânio, sendo dois de cada grupo. Dez voluntários usaram, por 24 horas, a moldeira contendo os discos de Ti c.p. Após este período três discos de titânio de cada grupo foram levados ao Microscópio Eletrônico de Varredura (MEV) para visualização do biofilme formado. O biofilme foi removido dos 17 discos restantes e, em sete deles, foi realizado o ensaio de MTT para quantificar as bactérias viáveis e em dez a Reação em Cadeia de Polimerase em Tempo Real (PCR Real Time, quantitativo) para quantificação total das bactérias aderidas e do Streptococcus oralis. Resultados: Os dados obtidos foram estatisticamente analisados utilizando Análise de Variância (ANOVA) One Way, seguido do pós-teste de Tamhane. Com relação a Ra, a diferença observada entres os Grupos 3 e 1 foi de 0,652 0,098μm e entre os Grupos 3 e 2 de 0,688 0,099μm. Nas micrografias foi observado biofilme aderido em todos os discos de titânio. O ensaio de MTT não evidenciou diferença significativa entre os grupos Grupo 1 (0,1190,048), 2 (0,1360,079) e 3 (0,1210,074), p=0,89. Os resultados da PCR Real Time não evidenciaram diferença significativa quanto ao número de bactérias entre os grupos estudados, tanto para o Universal (UN), Grupos 1- 372.477 (87.556;889.408), Grupo 2- 294.834 (51.742;648.674) e Grupo 3- 497.393 (150.596;2.333.567) com valor de p=0,88, quanto para o Streptococcus oralis (SO), Grupos 1-3.623(262;31.603), Grupo 2- 477(154;42.292) e Grupo 3- 9.002(1.053;147.154) com valor de p=0,42. Conclusões: Os discos do grupo 1 apresentaram rugosidade superficial igual aos do grupo 2 e ambos uma rugosidade superficial menor que os discos do grupo 3. A adesão bacteriana não foi influenciada pela rugosidade superficial dos discos de titânio. Não foi observada diferença significante na adesão bacteriana entre os grupos estudados, tanto pelo ensaio de MTT, quanto pela PCR real time. / Hypothesis of the Study: This study hypothesized that treated surfaces of discs commercially pure titanium (CP Ti) discs are more susceptible to bacterial adhesion than smooth surfaces. Objective: The objective of this study was to evaluate in situ the bacterial adherence in cp Ti discs subjected to two different surface treatments: double etching and anodizing. Methods: Sixty Ti specimens were divided into three groups: Group 1 - smooth cp Ti discs (control group), Group 2 - cp double Ti discs with surface acid etching (Master Pours Implant , Connection Prosthesis Systems LTD, SP., Brazil) and Group 3 - laser irradiated cp Ti discs subjected (Vulcan Actives , Connection Implant Systems LTD, SP., Brazil). Initially we evaluated the surface roughness (Ra) of all specimens. To assess in situ, individual trays were prepared and ten in each set of six disc titanium, two in each group. Ten volunteers wore what for 24 hours, the tray containing discs cpTi After this period three titanium disks from each group were taken to the Scanning Electron Microscope (SEM) to visualize the biofilm. The biofilm was removed from the 17 remaining disks, and seven of them, was held by the colorimetric MTT method to quantify living cells and ten to Real Time Polymerase Chain Reaction (Real Time PCR) for quantification of adhered bacteria and Streptococcus oralis. Results: Data were statistically analyzed using analysis of variance (ANOVA) One Way, followed by post-test Tamhane. With respect to Ra, the difference observed between the groups 3:01 was 0.652 0.098 m and between Groups 3 and 2 of 0.688 0.099 micrometers. In micrographs biofilm attached was observed in all titanium disks. The MTT method showed no significant difference among groups Group 1 (0.119 0.048), 2 (0.136 0.079) and 3 (0.121 0.074), p = 0.89. The Real Time PCR results showed no significant difference in number bacterial between the groups for both the Universal (UN), Group 1- 372.477 (87.556;889.408), Group 2- 294.834 (51.742;648.674) and Group 3- 497.393 (150.596;2.333.567) with p = 0, 88, as for Streptococcus oralis (SO), Group 1- 3.623(262;31.603), Group 2- 477(154;42.292) and Group 3- 9.002(1.053;147.154) with p = 0.42. Conclusions: The disks of group 1 showed surface roughness equal to Group 2 and both had a surface roughness smaller than the disks of group 3. The bacterial adhesion was not influenced by the surface roughness of the titanium disks. There was no significant difference in bacterial adhesion between the groups, both by MTT method, and by real time PCR.
32

Estudo das propriedades de filmes finos de nitreto de alumínio produzidos por processo de "magnetron sputtering" em regimes contínuo (DC) e alternado (RF).

Ivo de Castro Oliveira 00 December 2004 (has links)
Este trabalho tem como objetivo o estudo das propriedades de filmes finos de nitreto de alumínio produzidos por processo de "magnetron sputtering" usando-se alvo de alumínio de alto grau de pureza (99,999%). Os filmes foram produzidos em descargas a plasma sob regimes contínuo (DC) e alternado (RF). No curso deste estudo foi investigada a influência da temperatura do substrato (80 a 500 C), da concentração relativa do gás reativo (N2) e do papel exercido pelo gás de "sputtering" (argônio) sobre as propriedades físico-químicas dos filmes. Também foram investigadas as características elétricas de capacitores do tipo MIS (metal-isolante-semicondutor) em que o nitreto de alumínio era o isolante. Diferentes técnicas de caracterização foram empregadas na análise dos filmes, tais como: espectroscopia Raman, reto espalhamento de Rutherford (RBS), perfilometria, microscopia de força atômica, nanoindentação, espectroscopis de foto-elétrons (XPS). A qualidade dos filmes obtidos mostrou forte dependência das condições de deposição. Os filmes que apresentaram qualidades superiores, seja sob regime contínuo, seja sob regime alternado, foram aqueles crescidos em substratos aquecidos (< 200 C) e com argônio presente na composição da mistura gasosa da câmara de processos.
33

Caracterização morfológica e cristalográfica da zircônia após desgaste com pedra diamantada e elaboração de um protocolo para tratamento térmico regenerativo / Morphological and crystallographic characterization after zirconia grinding with diamond stone and development of a regenerative thermal treatment protocol

Candido, Lucas Miguel [UNESP] 07 April 2016 (has links)
Submitted by LUCAS MIGUEL CANDIDO null (candidomlucas@gmail.com) on 2016-05-09T20:57:38Z No. of bitstreams: 1 Dissertação Lucas_Para impressão.pdf: 1643203 bytes, checksum: c1cfc2af9a05d4f1d3fd774a80a7bb04 (MD5) / Rejected by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: O arquivo submetido está sem a ficha catalográfica. A versão submetida por você é considerada a versão final da dissertação/tese, portanto não poderá ocorrer qualquer alteração em seu conteúdo após a aprovação. Corrija esta informação e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-05-12T19:31:28Z (GMT) / Submitted by LUCAS MIGUEL CANDIDO null (candidomlucas@gmail.com) on 2016-05-13T19:10:05Z No. of bitstreams: 1 Dissertação Lucas_Final_Para repositório.pdf: 1713904 bytes, checksum: 739f3aab57282f6d4450a042bcb73fb0 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-16T16:18:12Z (GMT) No. of bitstreams: 1 candido_lm_me_arafo.pdf: 1713904 bytes, checksum: 739f3aab57282f6d4450a042bcb73fb0 (MD5) / Made available in DSpace on 2016-05-16T16:18:12Z (GMT). No. of bitstreams: 1 candido_lm_me_arafo.pdf: 1713904 bytes, checksum: 739f3aab57282f6d4450a042bcb73fb0 (MD5) Previous issue date: 2016-04-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As infraestruturas de zircônia (Y-TZP) comumente necessitam de ajustes que podem causar alterações nas propriedades do material. Estudos para a elaboração de um protocolo de desgaste menos prejudicial dessas infraesturuturas e determinação de um tratamento térmico regenerativo são pertinentes. Portanto, o objetivo deste estudo foi avaliar a superfície da zircônia tetragonal policristalina parcialmente estabilizada por ítria (Y-TZP) após desgaste com pedra diamantada com e sem irrigação em relação às fases cristalinas, composição química, morfologia superficial, rugosidade (Ra) e molhabilidade e também determinar o tempo e a temperatura necessários para reversão de fase (mt) a fim de se elaborar um protocolo de tratamento térmico regenerativo. Amostras sinterizadas de Y-TZP (LavaTM) foram distribuídas em 4 grupos: pré-sinterizado (PS), sinterizado (C), desgastado sem irrigação (DS) e desgastado com irrigação (DI). Foram realizados desgastes de 0,3 mm na superfície das amostras em dispositivo padronizador utilizando pedra diamantada em baixa rotação. As superfícies foram avaliadas em difratômetro de raios X (DRX), microscópio eletrônico de varredura (MEV) com espectroscopia de raios X por dispersão em energia (EDS), goniômetro e rugosímetro. Para a determinação da temperatura do tratamento térmico regenerativo (R) utilizou-se difratômetro de raios X in situ em temperatura (DRX in situ). As médias de ângulo de contato e Ra foram submetidas respectivamente, ao teste ANOVA one way seguido de Tukey (α=0,05) e Kruskal-Wallis seguido de Dunn (α=0,05). A sinterização eliminou a fase monoclínica das amostras do grupo PS. Houve uma maior quantidade de grãos monoclínicos na superfície das amostras do grupo DI em relação ao DS. O MEV indicou crescimento e acomodação dos grãos após a sinterização do grupo PS e para os grupos DS e DI a presença de riscos longitudinais paralelos ao sentido de desgaste, sem evidenciação dos grãos, sendo os vales de DI mais profundos. O EDS mostrou semelhança na composição dos grupos. As medianas e desvios padrão de Ra dos grupos PS, C, DS e DI foram respectivamente, 0,15 ± 0,02; 0,14 ± 0,02; 1,44 ± 0,13; 3,24 ± 0,75; sendo PS=C < DS < DI (p<0,01). As médias e desvios padrão de ângulo de contato para a mesma sequência dos grupos foram: 66,7 ± 2,2; 60,6 ± 4,1 e 56,6 ± 4,0; sendo C > DS = DI (p<0,01). O DRX in situ indicou reversão total de fase mt a partir de 700oC, porém o tratamento térmico só foi eficaz com temperatura de 800oC por 1 h. Concluiu-se que a melhor forma de se desgastar a zircônia com pedra diamantada é sem irrigação por causar menores alterações superficiais e que protocolos de aquecimento de 800oC e 900oC por 60 minutos ou 1000oC por 30 minutos são eficientes para a reversão total de fase m-t. / The zirconia infrastructures (Y-TZP) commonly need adjustments that can cause changes in their properties. Studies for developing a less harmful grinding protocol and for a regenerative heat treatment are relevant .The aim of this study was to evaluate the surface of tetragonal polycrystalline zirconia partially stabilized by yttria (Y-TZP) after grinding with diamond stone with or without irrigation comparing the crystalline content, chemical composition, surface morphology, roughness (Ra) and wettability and also determinate the time and temperature required for reversal phase transformation (mt) to create a regenerative thermal treatment protocol. Y-TZP sintered samples (LavaTM) were divided into four groups: pre-sintered (PS), sintered (C), dry grinding (DG) and wet grinding (WG). The grinding (0,3 mm) was performed on the sample surface in a equipment using diamond stone at low speed. Y-TZP surface was evaluated in X-ray diffractometer (XRD), scanning electron microscope (SEM) with X-ray energy dispersive spectroscopy (EDS), goniometer and profilometer. It was used a temperature in situ X-ray (in situ XRD) to determinate the temperature of the regenerative thermal treatment (R). Means of contact angle and Ra were analyzed respectively by ANOVA one way followed by Tukey (α=0.05) and Kruskal-Wallis followed by Dunn (α=0.05). The sintering process eliminated the monoclinic phase of the PS group. There were more monoclinic grains in the WG when compared with the DG. SEM showed growth and accommodation of grains after the sintering process of PS group; for groups WG and DG it were found the presence of parallel longitudinal scratches to the direction of wear, without disclosure of grain, with deeper valleys observed in the WG group. EDS showed similarity in groups’ composition. Ra medians and standard deviations of groups PS, C, DG and WG were, respectively, 0.15 ± 0.02; 0.14 ± 0.02; 1.44 ± 0.13; 3.24 ± 0.75; being PS=C < DG < WG (p<0.01). Means and standard deviations of contact angle for the same sequence for the groups were: 66.7 ± 2.2; 60.6 ± 4.1 e 56.6 ± 4.0; being C > DG = WG (p<001). The in situ XRD registered fully reversed phase transformation (m-t) from 700oC, but the regenerative thermal treatment was only effective with 800°C for 1 h. It was concluded that the best way to ground zirconia with diamond stone is without irrigation because it causes minor surface changes and heating protocols of 800oC and 900oC for 60 minutes or 1000°C for 30 minutes are effective to fully reversed phase m-t. / FAPESP: 2015/04552-3
34

Avaliação da resistência de união de reparos em resinas compostas convencionais e bulkfill / Repair bond strength evaluation in conventional composite resins and bulkfill

Trevisan, Tamara Carolina [UNESP] 08 April 2016 (has links)
Submitted by Tamara Carolina Trevisan null (tatatct@hotmail.com) on 2016-05-11T16:56:37Z No. of bitstreams: 1 DISSERTAÇÃO Tamara final.pdf: 952564 bytes, checksum: ebb18de0dbf1a31f23929f75262d327d (MD5) / Rejected by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: O arquivo submetido está sem a ficha catalográfica. Lembramos que a versão submetida por você é considerada a versão final da dissertação/tese, portanto não poderá ocorrer qualquer alteração em seu conteúdo após a aprovação. Corrija esta informação e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-05-13T16:10:54Z (GMT) / Submitted by Tamara Carolina Trevisan null (tatatct@hotmail.com) on 2016-05-16T22:27:11Z No. of bitstreams: 1 DISSERTAÇÃO Tamara Final Biblioteca.pdf: 1025909 bytes, checksum: 4723250559375bfac2090cfb75b0314b (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-05-17T18:48:39Z (GMT) No. of bitstreams: 1 trevisan_tc_me_arafo.pdf: 1025909 bytes, checksum: 4723250559375bfac2090cfb75b0314b (MD5) / Made available in DSpace on 2016-05-17T18:48:39Z (GMT). No. of bitstreams: 1 trevisan_tc_me_arafo.pdf: 1025909 bytes, checksum: 4723250559375bfac2090cfb75b0314b (MD5) Previous issue date: 2016-04-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Técnicas de reparos de restaurações vêm sendo amplamente utilizadas como um tratamento alternativo e conservador á substituição de restaurações defeituosas. O conhecimento do material a ser reparado e de um protocolo ideal, permitiria uma melhor relação biomecânica entre dente e material restaurador e possibilitaria técnicas eficazes e menos invasivas. O objetivo do presente estudo foi avaliar a resistência de união de reparo de diferentes resinas compostas, sob a influência de tratamentos de superfície, especialmente em relação a uma nova proposta comercial denominada de resinas "bulk fill". Para isso, foram confeccionados corpos de prova com diâmetro de 8mm por 4mm de altura, de diferentes classes de resinas compostas: Z350XT, Z250XT, Grandio, Epricord, Tetric Bulkfill, Xtra Fill e Sonic Fill (n=15). Estes passaram por processo de envelhecimento artificial, realizado por meio de armazenamento em estufa com saliva artificial por 3 meses, sendo realizada a troca da saliva semanalmente, e finalizado com termociclagem 5o e 55ºC por 20 segundos em água para 1000 ciclos. Foram distribuídos aleatoriamente em três subgrupos, de acordo com o tratamento de superfície (n=5): G1- Controle- sem tratamento prévio; G2- Jateamento óxido alumínio; G3- Jateamento óxido de sílica. Após a aplicação dos respectivos tratamentos de superfície, cada espécime foi reparado com resina composta Z100 em incrementos de aproximadamente 2mm e fotopolimerizado em um aparelho de fotopolimerização convencional (Bluephase, Ivoclar Vivadent, Liechtenstein) até obtenção 4 mm de altura. A seguir os espécimes foram submetidos a novo ciclo de envelhecimento artificial por uma semana em estufa com saliva artificial, e termociclagem 5o e 55ºC por 20 segundos em água para 1000 ciclos. As amostras foram seccionadas em seu longo eixo em máquina de corte (Isomet 1000, Buehler Ltd, Lake Bluff, IL, EUA), a fim de se obter espécimes no formato de paralelepípedo, com a linha de união localizada centralmente. Cada espécime foi individualmente fixado em máquina de microtração Micro Tensile Tester- MTT (BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 USA 1- 800-247-3368), e submetido a teste de microtração com velocidade de 0,5 mm/min e célula de carga de 500N. Realizou-se análise de variância para avaliar a influência dos diferentes materiais e tratamentos de superfície na resistência de união de reparos. O padrão de fratura observado nos reparos foi analisado por meio do teste de qui-quadrado( 2 ), para uma com significância estatística de 5%. A análise de variância mostrou que existe diferença estatisticamente significativa (p=0,001) entre a resistência coesiva dos materiais, e para interação material e tratamento de superfície sobre a resistência de união dos reparos (p=0,001). O teste de quiquadrado( 2 ) também mostrou que existe associação entre o tipo de fratura e as variáveis materiais e tratamentos de superfície (p=0.001). Concluindo que, as diferentes classes de resinas compostas testadas respondem de maneira diferente frente aos tratamentos de superfície aplicados, não sendo possível estabelecer um protocolo clínico ideal para procedimentos de reparo. Além disso, as resinas bulkfill testadas possuem resistência de união aceitável, semelhante às demais classes de resinas compostas, demonstrando que procedimentos de reparo são indicados para esses materiais. / Restoration repair techniques have been widely used as an alternative and conservative treatment for replacement of defective restorations. The knowledge of the material to be repaired and an ideal protocol would allow a better biomechanical relationship between tooth and restorative material and would allow techniques effective and less invasive. The aim of this study was to evaluate the repair's bond strength of different composite resins under the influence of surface treatments, especially in relation to a new commercial proposal called Bulk-fill Resin-based Composites. For this, specimens were prepared with 8 mm diameter by 4 mm in height, of different classes of composite resins: Z350XT, Z250XT, Grandio, Epricord, Tetric Bulkfill, Xtra Fill e Sonic Fill (n=15). These were submitted to artificial aging process by storing in an oven with artificial saliva for 3 months, and their exchange performed weekly and finished 5 o and 55°C thermocycling for 1000 cycles. They were randomly divided into three subgroups, according to the surface treatment (n=5): Control group- without treatment (G1), Aluminum oxide blasting (G2), Silica oxide blasting (G3). After applying the respective surface treatments, each specimen was repaired with composite resin (Z-100, 3M ESPE) in increments of 2mm, approximately, and light cured in a conventional light-curing unit (Bluephase, Ivoclar Vivadent, Liechtenstein) to obtain 4 mm height. Then specimens were subjected to a new cycle of artificial aging for one week incubated in artificial saliva and thermal cycling 5 and 55°C for 1000 cycles. The samples were sectioned in their long axis in a cutting machine (Isomet 1000, Buehler Ltd, Lake Bluff, IL, USA) in order to obtain the specimens in parallelepiped shape with union line centrally located. Each specimen was individually set at a micro-tensile machine Micro Tensile Tester - MTT (BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 USA 1-800-247-3368), and submitted to micro-tensile test at 0.5 mm/min speed with a 500 N load cell. It was performed variance analysis for there is influence of different materials and surface treatments on the bond strength of repair. The fracture pattern observed in repairs was analyzed using the chi-square test ( 2 ) with 5% statistical significance level. Analysis of Variance showed that there was a statistically significant difference (p=0.001) between the tensile strength of materials, and for interaction materials and surface treatment on bond strength of repair (p=0.001). There was association between the type of fracture and the variables material and surface treatments (p=0.001). It can be concluded that the different classes of composites tested respond differently compared to the applied surface treatment and it is not possible to establish a clinical protocol for repair procedures. Moreover, the tested bulk fill resins have acceptable bond strength, similar to other classes of composites, demonstrating that these materials are suitable for repair procedures.
35

Cerâmicas feldspáticas estratificadas e em blocos para sistema CAD/CAM: avaliação da topografia superficial, formação de biofilme inicial e viabilidade celular / Ceramic feldspathic for stratification technique and blocks for system CAD /CAM: evaluation of surface topography, biofilm formation and cell viability

Contreras, Lisseth Patricia Claudio [UNESP] 19 January 2017 (has links)
Submitted by LISSETH PATRÍCIA CLÁUDIO CONTRERAS null (lpatycc@gmail.com) on 2017-01-30T13:49:39Z No. of bitstreams: 1 Lisseth Patricia Claudio Contreras (5) (1).pdf: 2571557 bytes, checksum: 78dc304f1754247470830ef4eba24fa3 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-02-02T19:12:33Z (GMT) No. of bitstreams: 1 contreras_lpc_me_sjc.pdf: 2571557 bytes, checksum: 78dc304f1754247470830ef4eba24fa3 (MD5) / Made available in DSpace on 2017-02-02T19:12:33Z (GMT). No. of bitstreams: 1 contreras_lpc_me_sjc.pdf: 2571557 bytes, checksum: 78dc304f1754247470830ef4eba24fa3 (MD5) Previous issue date: 2017-01-19 / O objetivo deste estudo foi avaliar a topografia e a formação de biofilme na superfície de cerâmicas feldspáticas obtidas através de duas técnicas de confecção e dois tratamentos de superfície, assim como avaliar a viabilidade do crescimento de fibroblastos gengivais humanos (FMM-1) sobre estes materiais. Foram confeccionados 52 blocos de cada tipo de cerâmica feldspática: VM9 obtida através da técnica da estratificação e cerâmica Vita Blocs Mark II (VMII) para o sistema CAD/CAM (ambas, Vita Zahnfabrik). As superfícies dos blocos foram padronizadas em politriz nas dimensões de 4,5 x 4,5 x 1,5 mm e os blocos foram divididos em dois tratamentos de finalização de superfície: polimento com borrachas Ceramisté + pasta de polimento e aplicação de glaze spray + sinterização. Os parâmetros de rugosidade Ra e Rsm foram mensurados através de um rugosímetro de contato. As amostras foram esterilizadas e, em seguida contaminadas (n=10) para formação de biofilme heterotípico inicial de S. mutans, S. sanguinis e C. albicans, cuja aderência foi quantificada por contagem de unidades formadoras de colônias (UFC/mL). O teste MTT foi empregado para avaliação da viabilidade celular dos materiais ao crescimento de fibroblastos gengivais humanos (FMM-1) em 24 h e 7 dias (n=12). Foram realizadas análises qualitativas da superfície dos espécimes através de microscopia eletrônica de varredura (MEV) e perfilometria óptica 3D. A energia livre de superfície (ELS) foi calculada a partir de análises de goniômetria com líquidos polar e apolar em 10 amostras de 15 x 1 5 x 1,5 mm. Os resultados de Ra, RSm e ELS foram submetidos à análise de variância ANOVA 2 fatores (material x tratamento de superfície) seguido por teste de Tukey (ambos, α=95%), e os dados de UFC fatores (material x tratamento x micro-organismos) e MTT (material x tratamento x tempo) foram avaliados por ANOVA 3 fatores e teste Tukey (α=95%). As imagens de MEV e perfilometria foram descritas. As cerâmicas polidas apresentaram menor rugosidade (Ra p=0,015; RSm p=0,049) e maior ELS (p=0,00), sendo que a mais alta Ra foi verificada para VM9 glazeada. A aderência bacteriana foi influenciada pela interação de todos os fatores (p=0,018). Os Streptococcus formaram em maior número em todos os materiais, mas sobre VMII polida não houve aderência de C. albicans. Inicialmente, os materiais apresentaram ausência de citotoxicidade, mas a viabilidade celular de todos os grupos foi reduzida após 7 dias (p=0,00). As micrografias mostram que a aderência de micro-organismos ocorreu independente de irregularidades na topografia dos materiais, e as imagens de perfilometria ressaltaram o padrão de ranhuras das amostras polidas e o acúmulo de glaze em “ilhas” nas amostras glazeadas. Foi possível concluir que ambas técnicas de obtenção resultam em cerâmicas feldspáticas biocompatíveis e que a finalização da superfície por polimento resultou em menor rugosidade média, maior ELS e menor aderência de C. albicans. / The objective of this study was to evaluate the topography and surface biofilm formation of feldspathic ceramics obtained through two techniques of preparation and two surface treatments, as well as to evaluate the viability of human gingival fibroblasts (FMM-1) growth on these materials. A total of 52 blocks of each type of feldspathic ceramic were made: VM9 obtained by the stratification technique and Vita Blocs Mark II (VMII) for the CAD/CAM system (both, Vita Zahnfabrik). The blocks’ surfaces were standardized in a polishing machine to the dimensions of 4.5 x 4.5 x 1.5 mm and blocks were divided into two surface finishing treatments: polishing with Ceramisté rubbers + polishing with paste; and glaze application + sintering. The Ra and RSm roughness parameters were measured through a contact rugosimeter. Samples were sterilized and then contaminated (n = 10) for initial heterotypic biofilm formation of S. mutans, S. sanguinis and C. albicans, whose adherence was quantified by counting colony forming units (CFU/mL). The MTT test was used to evaluate the cellular viability of the materials to the growth of human gingival fibroblasts (FMM-1) in 24 h and 7 days (n=12). Qualitative analyzes of the specimens’ surface were performed using a scanning electron microscopy (SEM) and 3D optical profilometry. Surface free energy (SFE) was calculated from goniometry analyzes of polar and apolar liquids in 10 samples of 15 x 15 x 1.5 mm. The results of Ra, RSm and ELS were subjected to 2-way ANOVA (Material x surface treatment) followed by Tukey’s test (both, α=95%), and UFC (material x surface treatment x microorganisms) and MTT (material x surfacetreatment x time) data were evaluated by 3-way ANOVA and Tukey’s test (α=95%). SEM and profilometry images were described. The polished ceramics presented lower roughness (Ra p=0.015; RSm p=0.049) and higher SFE (p=0.00), with the highest Ra being verified for glazed VM9. Bacterial adherence was influenced by the interaction of all factors (p=0.018). Streptococcus formed in greater number in all materials, but on polished VMII there was no adherence of C. albicans. Initially, the materials showed no cytotoxicity, but the cell viability of all groups was reduced after 7 days (p=0.00). Micrographs showed that microorganisms adherence occurred regardless of irregularities in the topography of the materials, and the profilometry images emphasized the grooved pattern of the polished samples and the glaze accumulation in "islands" in glazed samples. The surface treatments had greater influence than the technique of making the feldsphapatic ceramics. It could be concluded that both obtaining techniques resulted in biocompatible feldsphatic ceramics and that the surface finishing by polishing resulted in lower mean roughness, higher SFE and lower C. albicans adhesion.
36

Influência da rugosidade de superfície e ação de diferentes desinfetantes na formação de biofilme em resina acrílica para prótese ocular e sua biocompatibilidade em contato com células da conjuntiva humana / Influence of surface roughness and action of different disinfectants on the formation of biofilm in acrylic resin for ocular prosthesis and their biocompatibility in contact with cells human conjunctiva cells

Andreotti, Agda Marobo [UNESP] 31 August 2017 (has links)
Submitted by Agda Marobo Andreotti (36897500836) on 2017-10-19T21:29:31Z No. of bitstreams: 1 TESE DOUTORADO AGDA MAROBO ANDREOTTI.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-23T18:36:23Z (GMT) No. of bitstreams: 1 andreotti_am_dr_araca.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) / Made available in DSpace on 2017-10-23T18:36:23Z (GMT). No. of bitstreams: 1 andreotti_am_dr_araca.pdf: 5621947 bytes, checksum: ad2de971e6e9dcd6b35700dd4f7bc0d1 (MD5) Previous issue date: 2017-08-31 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O controle da formação de biofilme é essencial para manter a saúde da cavidade anoftálmica dos portadores de prótese ocular. As propriedades físicas da resina acrílica, como a sua rugosidade, podem interferir na adesão de microrganismos nas próteses e na formação de biofilmes. Sendo assim, é necessário utilizar soluções de limpeza eficazes e que não causem irritação tecidual na conjuntiva ocular. O objetivo desse trabalho foi verificar a influência da rugosidade de superfície da resina acrílica utilizada na confecção de próteses oculares na formação de biofilme bacteriano, bem como avaliar a eficácia antimicrobiana e citotoxicidade de diferentes soluções para desinfecção de próteses oculares. Para a análise da rugosidade, corpos de prova de resina acrílica foram confeccionados e divididos em 5 grupos de acordo com a granulação de lixa de polimento utilizada: 120, 400, 800, 1200 e 1200S (lixa + sílica). A rugosidade dos corpos de prova foi mensurada por meio de perfilômetro e imagens de Microscopia de Força Atômica foram obtidas para cada grupo. O crescimento das espécies Staphylococcus aureus e Staphylococcus epidermidis sobre os corpos de prova foi avaliado após 4 e 24h, por meio da contagem das Unidades Formadoras de Colônia (UFC)/mL. O efeito dos seguintes tratamentos: soro fisiológico, sabão neutro, clorexidina 4%, pastilhas efervescentes Efferdent®, triclosan 1% e citronela sobre biofilme formado sobre os corpos de prova de resina acrílica também foi avaliado por meio da determinação do número de UFC/mL. A citotoxicidade dos agentes antimicrobianos foi avaliada por meio dos testes de MTT e Neutral Red, após tratamento dos corpos de prova, diariamente, por 1, 7, 15, 30, 60 e 90 dias com as soluções já citadas, sendo avaliados ao fim de cada período. Os dados obtidos foram submetidos à análise estatística adequada, considerando se provinham de dados paramétricos ou não paramétricos. Os resultados demonstraram que os menores valores de rugosidade foram encontrados no grupo 800, 1200 e 1200S. A contagem microbiana foi menor no grupo 1200S e esta diferiu estatisticamente (p>0,05) do controle para ambos os tempos de avaliação e bactérias. Na análise da ação antimicrobiana das soluções para desinfecção, todos os protocolos promoveram redução do crescimento dos microrganismos testados comparados ao controle (crescimento sem a presença do antimicrobiano), sendo que os grupos submetidos ao tratamento com clorexidina 4%, pastilhas efervescentes Efferdent® e triclosan 1% eliminaram o biofilme (p>0,01). Ainda nos ensaios de citotoxicidade, em todos os grupos foi observada proliferação celular das células da conjuntiva acima de 84% (p>0,05). Dessa forma, conclui-se que a rugosidade não interfere significativamente na adesão bacteriana e formação de biofilme, exceto para o grupo 1200S, e que os protocolos de limpeza com imersão em clorexidina 4%, pastilhas efervescentes Efferdent® e triclosan 1% são totalmente eficazes na desinfecção e não apresentam citotoxicidade para com as células da conjuntiva humana, sugerindo sua indicação para desinfecção de próteses oculares. / The control of biofilm formation is essential to maintain the health of anophthalmic cavity of ocular prosthesis wearers. The physical properties of the acrylic resin, such as surface roughness, may interfere with the adhesion of microorganisms to the prostheses. Therefore, it is necessary to use cleaning solutions that are effective and do not cause tissue irritation in ocular conjunctiva. The aim of this study was to verify the influence of surface roughness of the acrylic resin used in the preparation of ocular prosthesis in the formation of bacterial biofilm, as well as to evaluate the antimicrobial efficacy and cytotoxicity of different disinfectants in ocular prostheses. For roughness analysis, acrylic resin samples were prepared and divided into 5 groups according to the granulation of polishing sandpaper used: 120, 400, 800, 1200 and 1200S (sandpaper + silica). The roughness of the samples was measured using a profilometer and Atomic Force Microscopy images were obtained for each group. The microbial growth for Staphylococcus aureus and Staphylococcus epidermidis on the samples was evaluated after 4 and 24 h by counting the Colony Forming Units (CFU)/mL. The effect of the following solutions was also evaluated by CFU/mL: non treated group (immersed in saline solution), neutral soap, 4% chlorhexidine, Efferdent® effervescent tablets, 1% triclosan and citronella. The cytotoxicity of the solutions was evaluated by MTT and Neutral Red after treating the samples daily for 1, 7, 15, 30, 60 and 90 days with the solutions already mentioned, being evaluated at the end of each period. Data were submitted to proper statistical analysis, considering whether data were parametric or non-parametric. The results showed that the lowest roughness values were found in groups 800, 1200 and 1200S. 1200S group also presented the lowest values of microbial growth statistically different from control group (p>0,05), for both periods and bacteria evaluated. In the analysis of the solutions, compared to the control group (microbial growth without the presence of the antimicrobial), all protocols promoted a reduction in the growth of the microorganisms, and the groups submitted to disinfection with 4% chlorhexidine, Efferdent® effervescent tablets and 1% triclosan eliminated the biofilm (p>0,01). In addition, all groups showed cell proliferation of conjunctival cells above 84% in the cytotoxicity assays (p>0,05). Thus, it was concluded that the roughness does not significantly interfere in the adhesion of the microorganisms, except for group 1200S, and that the cleaning protocols with 4% chlorhexidine, Efferdent® effervescent tablets and 1% triclosan are totally effective in the disinfection and do not present cytoxicitiy with human conjunctive cells, what suggests their indication for cleaning of ocular prosthesis. / CNPq: 141722/2015-0
37

Grafeno e seus derivados: estudo das propriedades de superfície e processos de transferência para substratos poliméricos

Costa, Mariana Caldeira Ferraz da 13 December 2017 (has links)
Submitted by Marta Toyoda (1144061@mackenzie.br) on 2018-02-07T19:57:00Z No. of bitstreams: 2 Mariana Caldeira Ferraz da Costa.pdf: 4262658 bytes, checksum: 96704c9f44fdadcc81a3e3b28a4bb35b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Paola Damato (repositorio@mackenzie.br) on 2018-05-04T12:44:02Z (GMT) No. of bitstreams: 2 Mariana Caldeira Ferraz da Costa.pdf: 4262658 bytes, checksum: 96704c9f44fdadcc81a3e3b28a4bb35b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-04T12:44:02Z (GMT). No. of bitstreams: 2 Mariana Caldeira Ferraz da Costa.pdf: 4262658 bytes, checksum: 96704c9f44fdadcc81a3e3b28a4bb35b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-12-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Fundo Mackenzie de Pesquisa / This dissertation describes a study of surface properties of graphene obtained by chemical vapor deposition (CVD) to evaluate its hydrophobicity and wetting transparency of this material deposited onto several hard substrates, for instance silicon wafer, glass, etc. To this end, contact angle measurements and the calculation of polar and dispersive components were performed to these samples, submitted or not to a thermal treatment at inert atmosphere. Moreover, a study of the influence of factors that rule transfers processes grounded in Direct Dry Transfer (DDT) of two-dimensional materials (CVD graphene and graphene oxide - GO) onto polymeric surfaces of two or three dimensions was executed, such as surface properties and chemical structure to each materials (two-dimensional and polymers) and rheological properties of polymers. The results indicated graphene is hydrophobic and partially wetting transparent due to influences of the nature of substrates in which it is deposited. However, the thermal treatment at inert atmosphere altered significantly the surface properties of this material, indicating that, for graphene, such properties are strongly influenced by molecules adsorbed onto surface, achieving results very close to those presented in the literature. Talking about transfer processes of 2D materials onto polymers surfaces, the evaluation of surface properties demonstrated to be efficient in predicting the quality and quantity of CVD graphene transferred using DDT. However, factors such as rheological properties and chemical structure must be evaluated concomitantly. Lastly, the efficacy of a technique developed to cover polymer surfaces of three-dimensional substrates with graphene oxide using injection molding processing was presented. / Esta dissertação relata um estudo das propriedades de superfície do grafeno obtido via deposição química na fase vapor (CVD) para avaliação da sua hidrofobicidade e transparência da molhabilidade, quando esse material se encontra depositado em diferentes substratos rígidos, tais como wafer de silício, vidro, entre outros. Para isso, medidas de ângulo de contato e cálculos das componentes polares e dispersivas foram realizados em amostras submetidas ou não a tratamento térmico em atmosfera inerte. Além disso, foi executado um estudo sobre a influência dos fatores que regem processos de transferência fundamentados na técnica Direct Dry Transfer (DDT), envolvendo materiais bidimensionais (grafeno CVD e óxido de grafeno – GO) para superfícies poliméricas, sejam elas de duas ou três dimensões, tais como as propriedades de superfície e estrutura química de ambos os materiais (bidimensionais e polímeros) e as propriedades reológicas dos polímeros. Os resultados indicaram que o grafeno é hidrofóbico e parcialmente transparente ao molhamento devido a influências da natureza do substrato no qual se encontra depositado. O tratamento térmico em atmosfera inerte altera significativamente as propriedades de superfície desse material, indicando que, para o grafeno, tais propriedades são fortemente influenciadas por moléculas adsorvidas na superfície, obtendo resultados muito próximos daqueles previstos teoricamente. Com relação aos processos de transferência de materiais 2D para polímeros, a avaliação das propriedades de superfície dos materiais se demonstrou eficiente na previsão da qualidade e quantidade do grafeno CVD transferido usando a técnica DDT. Contudo, fatores como propriedades reológicas e estrutura química devem ser avaliados concomitantemente. Por último, foi demonstrada a eficiência de uma técnica desenvolvida para recobrimento de superfícies poliméricas de substratos tridimensionais com óxido de grafeno utilizando processamento de moldagem por injeção.
38

EFEITO DE SOLUÇÕES HIGIENIZADORAS NA ESTABILIDADE DE COR E RUGOSIDADE DE RESINAS ACRÍLICAS PARA BASE DE DENTADURA / EFFECT OF CLEANING SOLUTIONS ON THE COLOR STABILITY AND ROUGHNESS OF DENTURE BASE ACRYLIC RESINS

Nora, Bárbara Dala 21 July 2016 (has links)
The aim of the study was to evaluate the effect of cleaning substances in color stability and roughness of acrylic resins to base definitive or provisional dentures polymerized by different methods. The factors evaluated were the type of acrylic resin (autopolymerized, heat-polymerized or microwave-polymerized), immersion media (alkaline peroxide, 0,5% sodium hypochlorite or artificial saliva as control) and time. Seventy-two disc-shaped specimens (8mmx2mm) were prepared (n = 8) and divided according to the experimental design. To determine color change (ΔE00) was used CIEDE2000 equation. The Ra parameter was used to determine the surface roughness of the samples. Baseline measurements were performed 24 hours after hydration (T0) and then the cps were subjected to 20 minutes daily immersions in media. New readings were performed in 30 (T1), 60 (T2) and 90 days (T3). Data were submitted to Analysis of Variance Test for Repeated Measures (Two-way ANOVA) followed by Tukey s Test (p <0,05). Significant effect was found over time, especially in color values (T2 and T3) and roughness for the autopolymerized resin (T3), which behaved worse. The solutions influenced color and roughness. Color stability and roughness were modified by means of immersion and varied depending on the type of polymerization, however the protocol of 20 minutes of immersion in cleaning solutions proved to be safe within the evaluated period for heat-polymerized and microwave-polymerized resin. / O objetivo do estudo foi avaliar o efeito substâncias de higienização na estabilidade de cor e na rugosidade de resinas acrílicas para base de dentadura definitiva ou provisória, polimerizadas por diferentes métodos. Os fatores avaliados foram o tipo de resina acrílica (autopolimerizável, termopolimerizável ou cura por micro-ondas), meios de imersão (peróxido alcalino, hipoclorito de sódio a 0,5% ou saliva artificial como controle) e tempo. Setenta e dois corpos de prova (cps) em forma de disco (8mmx2mm) foram confeccionados (n=8) e divididos conforme delineamento experimental. Para determinar alteração de cor (ΔE00) foi utilizada a equação CIEDE2000. O parâmetro de Ra foi empregado para determinar a rugosidade superficial média das amostras. As mensurações iniciais foram feitas 24h após a hidratação (T0) e a seguir os cps foram submetidos a imersões diárias de 20 minutos nos meios. Novas leituras foram realizadas nos tempos de 30 (T1),60 (T2) e 90 dias (T3). Os dados foram submetidos à Análise de Variância com dois fatores para Medidas Repetidas seguido de Teste de Tukey (p<0,05). Efeito significativo foi encontrado ao longo do tempo, principalmente nos valores de cor (T2 e T3) e rugosidade da resina autopolimerizável (T3), a qual se comportou de maneira inferior. Os meios influenciaram cor e rugosidade. Estabilidade de cor e rugosidade foram modificadas pelos meios de imersão e variaram conforme o tipo de polimerização, porém o protocolo de imersão em 20 minutos nas soluções higienizadoras mostrouse seguro dentro do período avaliado para as resinas termopolimerizável e cura por micro-ondas.
39

Caracterização morfológica e cristalográfica da zircônia após desgaste com pedra diamantada e elaboração de um protocolo para tratamento térmico regenerativo /

Candido, Lucas Miguel. January 2016 (has links)
Orientador: Lígia Antunes Pereira Pinelli / Resumo: As infraestruturas de zircônia (Y-TZP) comumente necessitam de ajustes que podem causar alterações nas propriedades do material. Estudos para a elaboração de um protocolo de desgaste menos prejudicial dessas infraesturuturas e determinação de um tratamento térmico regenerativo são pertinentes. Portanto, o objetivo deste estudo foi avaliar a superfície da zircônia tetragonal policristalina parcialmente estabilizada por ítria (Y-TZP) após desgaste com pedra diamantada com e sem irrigação em relação às fases cristalinas, composição química, morfologia superficial, rugosidade (Ra) e molhabilidade e também determinar o tempo e a temperatura necessários para reversão de fase (mt) a fim de se elaborar um protocolo de tratamento térmico regenerativo. Amostras sinterizadas de Y-TZP (LavaTM) foram distribuídas em 4 grupos: pré-sinterizado (PS), sinterizado (C), desgastado sem irrigação (DS) e desgastado com irrigação (DI). Foram realizados desgastes de 0,3 mm na superfície das amostras em dispositivo padronizador utilizando pedra diamantada em baixa rotação. As superfícies foram avaliadas em difratômetro de raios X (DRX), microscópio eletrônico de varredura (MEV) com espectroscopia de raios X por dispersão em energia (EDS), goniômetro e rugosímetro. Para a determinação da temperatura do tratamento térmico regenerativo (R) utilizou-se difratômetro de raios X in situ em temperatura (DRX in situ). As médias de ângulo de contato e Ra foram submetidas respectivamente, ao teste ANOVA one wa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The zirconia infrastructures (Y-TZP) commonly need adjustments that can cause changes in their properties. Studies for developing a less harmful grinding protocol and for a regenerative heat treatment are relevant .The aim of this study was to evaluate the surface of tetragonal polycrystalline zirconia partially stabilized by yttria (Y-TZP) after grinding with diamond stone with or without irrigation comparing the crystalline content, chemical composition, surface morphology, roughness (Ra) and wettability and also determinate the time and temperature required for reversal phase transformation (mt) to create a regenerative thermal treatment protocol. Y-TZP sintered samples (LavaTM) were divided into four groups: pre-sintered (PS), sintered (C), dry grinding (DG) and wet grinding (WG). The grinding (0,3 mm) was performed on the sample surface in a equipment using diamond stone at low speed. Y-TZP surface was evaluated in X-ray diffractometer (XRD), scanning electron microscope (SEM) with X-ray energy dispersive spectroscopy (EDS), goniometer and profilometer. It was used a temperature in situ X-ray (in situ XRD) to determinate the temperature of the regenerative thermal treatment (R). Means of contact angle and Ra were analyzed respectively by ANOVA one way followed by Tukey (α=0.05) and Kruskal-Wallis followed by Dunn (α=0.05). The sintering process eliminated the monoclinic phase of the PS group. There were more monoclinic grains in the WG when compared with the DG. SEM sho... (Complete abstract click electronic access below) / Mestre
40

Avaliação microbiológica, física e mecânica de materiais resilientes modificados pela adição de antimicrobianos para tratamento de estomatite protética / Microbiological, physical and mechanical evaluation of resilient materials modified by the addition of antimicrobial agents for denture stomatitis\' treatment

Bueno, Mírian Galvão 31 October 2011 (has links)
No presente estudo, a proposta foi avaliar a ação antimicrobiana sobre o biofilme de Candida albicans (SC 5314) e determinar a mínima concentração inibitória (MCI) de cinco fármacos utilizados no tratamento de estomatite protética (nistatina, miconazol, cetoconazol, itraconazol e diacetato de clorexidina), quando incorporados em reembasadores resilientes temporários à base de resina acrílica (Trusoft e Softone) bem como o efeito dessa modificação sobre as propriedades de dureza Shore A e rugosidade superficial dos materiais. Para determinação das MCIs, o biofilme fúngico foi formado sobre corpos de prova circulares (10 mm x 1 mm) dos materiais (n = 6) modificados (experimentais) ou não (controle) pela adição dos fármacos. Diferentes concentrações dos antimicrobianos foram testadas e a viabilidade celular determinada espectrofotometricamente pelo ensaio de redução de sais de tetrazólio- XTT, nos períodos de 24 h, 48 h, 7 e 14 dias. As medidas espectrofotométricas foram convertidas em porcentagens de redução fúngica e as MCIs determinadas como aquelas suficientes para inibir 90% ou mais do crescimento de C. albicans. Para os ensaios de dureza e rugosidade, corpos de prova retangulares (36 mm x 7 mm x 6 mm) dos materiais resilientes (n= 8) foram confeccionados sem (controle) ou com incorporação dos fármacos nas MCIs previamente definidas. Após armazenamento em água destilada a 37°C por 24 h, 7 e 14 dias, foram realizados os testes de dureza em durômetro Shore A (Woltest, GSD-709A) e de rugosidade superficial em rugosímetro (Surftest SJ-301). Os resultados foram analisados estatisticamente por ANOVA 3 fatores, seguida pelo teste de Tukey (=0,05). De acordo com os resultados, as MCIs determinadas para fármacos incorporados aos materiais resilientes foram: 0,032, 0,256, 0,128, 0,256 e 0,064 g/mL para nistatina, miconazol, cetoconazol, itraconazol e clorexidina, respectivamente. A adição dos antimicrobianos em ambos os materiais não alterou os valores de dureza, ou resultou na sua diminuição em relação ao controle, exceto para a incorporação de miconazol ao Softone, que demonstrou maiores médias após 14 dias (P=0,0035). A incorporação de nistatina aos dois materiais, de clorexidina ao Trusoft e de cetoconazol ao Softone não alterou os valores de rugosidade em relação ao controle após 7 e 14 dias (P>0,05). Nesses períodos, o itraconazol aumentou a rugosidade dos materiais (P<0,0001). Em relação às 24 h iniciais, o período de 14 dias mostrou que a rugosidade com a adição de nistatina, miconazol e cetoconazol foi reduzida para o Trusoft (P<0,05) e não apresentou alteração para o Softone (P>0,05). Foi possível concluir que a incorporação dos antimicrobianos testados inibiu o crescimento de C. albicans nos materiais ao longo de 14 dias de avaliação. A adição de todos os fármacos testados, exceto o miconazol no Softone, não causou alterações deletérias à dureza dos materiais resilientes no período avaliado. No período final, a adição de nistatina, miconazol e cetoconazol em ambos os reembasadores e de clorexidina no Trusoft não resultou em efeitos adversos na rugosidade. / The purpose of this study was to evaluate the antimicrobial action on Candida albicans biofilm (SC5314) and determine the minimum inhibitory concentration (MIC) of five drugs for denture stomatitis\' treatment (nystatin, miconazole, ketoconazole, itraconazole, and chlorhexidine diacetate) incorporated into temporary denture relines (Trusoft e Softone) as well the effect of this addition on the Shore A hardness and surface roughness of the materials. For MIC determination, the fungal biofilm was formed on disc specimens (10mm x 1 mm) of the materials (n= 6) modified (experimental) or not (control) by the addition of drugs. Different dosages of the antimicrobials were tested and cellular viability was determined by spectrophotometric tetrazolium salt XTT reduction assay at 24 h, 48 h, 7 and 14 days of incubation. The spectrophotometric measurements were converted to percentage reduction in candidal growth and the MICs were determined as the concentrations necessary to inhibit 90% or more of fungal viability. For hardness and surface tests, rectangular specimens (36 mm X 7 mm X 6 mm) of the resilient materials (n= 8) were made without (control) or with incorporation of the MIC drugs. After storage in distilled water at 37°C for 24h, 7 and 14 days, the hardness tests were performed using a Shore A hardness tester (Woltest, GSD-709A) and the roughness assay was conducted in a surface roughness tester (Surftest SJ-301). Data were statistically analyzed by 3-way ANOVA followed by Tukeys test (=.05). According to the results, MICs of the drugs incorporated into the material were: 0.032, 0.256, 0.128, 0.256 e 0.064 g/mL for nystatin, miconazole, ketoconazole, itraconazole and chlorhexidine, respectively. The addition of the tested antimicrobial agents in both materials demonstrated no evident hardness change or resulted in its decrease compared to the control, except for miconazole incorporation into Softone, which increased the hardness values after 14 days (P = .0035). The addition of nystatin into the two materials, chlorhexidine into Trusoft and ketoconazole into Softone resulted in no significant changes of roughness values compared to the control after 7 and 14 days (P>.05). In these periods, itraconazole promoted increase of the roughness for both materials (P<.0001). Compare to the 24- h period, the roughness at 14- day time with the addition of nystatin, miconazole and ketoconazole was reduced for Trusoft (P<.05) and remained unaffected for Softone (P> .05). It can be concluded that the incorporation of antimicrobial agents inhibited the C. albicans growth on the materials up to 14 days. The addition of all tested drugs, except for the miconazole into Softone, resulted in no deleterious effects on hardness of the resilient materials over the evaluation time. At the end period, the incorporation of nystatin, miconazole and ketoconazole into both denture relines and chlorhexidine into Trusoft resulted in no detrimental changes on the roughness.

Page generated in 0.4905 seconds