• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 28
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 96
  • 96
  • 64
  • 60
  • 27
  • 18
  • 16
  • 16
  • 16
  • 16
  • 14
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Pita, Murillo Sucena 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
72

Segurança biológica de implantes mamários de silicone: interrelação entre processos esterilizantes e biocompatibilidade / Biological safety of silicone mammary implants: interrelationship between sterilization processes and biocompatibility

Azevedo, Janice Campos de 25 March 2004 (has links)
Os implantes mamários de silicone têm sido empregados, tanto nas cirurgias de aumento das mamas, quanto na reconstrução do tecido mamário após mastectomia. A segurança biológica dos implantes de silicone merece estudo relacionado aos processos de esterilização empregados, pois podem constituir-se em fator de comprometimento da estrutura química do polímero e, conseqüentemente, da biocompatibilidade. Este estudo consistiu na avaliação da biocompatibilidade de implantes mamários de silicone após terem sido submetidos aos processos de esterilização por calor seco, radiação gama e óxido de etileno. O parâmetro avaliado foi a viabilidade celular, empregando o método de difusão em agar e de captura do vermelho neutro. As amostras compreenderam implantes de silicone gel lisos, texturizados e revestidos com poliuretano e implantes texturizados pré-cheios com solução salina. Também foi realizado o teste de endotoxinas bacterianas pelo método do LAL e determinação da taxa de migração do gel de silicone (teste de bleed). Os três métodos de esterilização mostraram-se igualmente eficientes pela comprovação da condição de esterilidade dos implantes através de metodologia descrita na Farmacopéia Americana 27 edição. Os níveis de endotoxinas bacterianas dos implantes, também atenderam aos requisitos dos compêndios oficiais. Na avaliação da biocompatibilidade todos os implantes, independente dos processos de esterilização utilizados, apresentaram ausência de citotoxicidade. Os resultados do teste de bleed mostraram uma maior taxa de migração de gel para os implantes de superfície lisa em comparação com os implantes de superfície texturizada e revestida com poliuretano, quando esterilizados por calor seco. Ao comparar a taxa de migração do gel para os implantes de superfície lisa esterilizados por calor seco e óxido de etileno, obteve-se uma maior taxa de migração para aqueles implantes esterilizados por óxido de etileno. As diferentes avaliações realizadas neste estudo abrangeram aspectos biológicos, químicos e físicos relevantes para garantir um produto de boa qualidade e que, por assegurar a manutenção da característica de biocompatibilidade, resulta na segurança biológica deste tipo de implante. / Silicone breast implants have been widely used for mammary augmentation and reconstruction surgery. Biological safety of these implants can be damaged by sterilization methods. This study consisted of the biocompatibility assessment of breast implants through cell viability, employing the agar diffusion test and neutral red uptake. Four silicone breast implants were tested: smooth, textured, polyurethane covered silicone gel breast implant and textured saline-filled breast implant. Sterilization methods comprised dry-heat, ethylene oxide and γ-radiation. Detection of bacterial endotoxins employing LAL test and gel bleed was also performed. The three methods of sterilization revealed equally efficacious, through the sterility confirmation of implants employing methodology described in 27th edition of United States Pharmacopeia. At the same way the leveis of bacterial endotoxins of implants accorded with the pharmacopeial requirements. In theevaluation of biocompatibility ali the implants, independently of the sterilization process used, showed no cytotoxicity signals. The results of gel bleed revealed a higher migration rate from the smooth implants in comparison with the textured and polyurethane-covered implants sterilized by dry-heat. When was compared the gel migration of smooth implants sterilized by dry-heat and ethylene oxide, was obtained a higher rate of gel bleed of those implants sterilized by ethylene oxide. The different evaluations performed in this study comprised biological, chemical and physical aspects, that are relevant to assure a good quality product and by having maintained the characteristics of biocompatibility, resulted in the biological safety on this kind of implant.
73

Estudo mecânico da conexão implante/abutment utilizando parafusos convencionais e parafusos experimentais cone morse / Mechanical study of the implant/abutment connection using conventional screws and experimental conical screws

Coppedê, Abílio Ricciardi 15 July 2011 (has links)
A proposta deste estudo foi avaliar o comportamento mecânico de dois designs de conexão implante/abutment; hexágono externo e triângulo interno, utilizando parafusos convencionais e parafusos experimentais cone morse. O estudo foi dividido em duas fases: na primeira, foi avaliado o efeito do carregamento mecânico na perda de torque dos parafusos. 40 implantes foram utilizados. Os implantes e abutments foram divididos em 4 grupos: Grupo 1: hexágono externo/parafuso convencional (HE); Grupo 2: triângulo interno/parafuso convencional (TI); Grupo 3: hexágono externo/parafuso cone morse (HECM); Grupo 4: triângulo interno/parafuso cone morse (TICM). Os abutments foram instalados em seus respectivos implantes com torque de aperto de 32Ncm; após intervalo de 10 minutos, foram medidos os valores dos torques de desaperto. Os abutments foram instalados novamente com torque de 32Ncm, e após 10 minutos foram carregados mecanicamente, simulando 1 ano de função oral normal; após o carregamento, os torques de desaperto dos parafusos foram medidos novamente. Os dados foram analisados com o teste one-way ANOVA, com nível de significância de p≤0,05%. Análises por microscopia óptica foram realizadas antes e após os ensaios. Na segunda fase, foi avaliada a resistência à flexão dos conjuntos implante/abutment. Os mesmos 40 conjuntos foram utilizados. Os testes foram realizados em máquina universal de ensaios, com célula de carga de 500 kgf, deslocamento de 1mm/min, e inclinação de 45°. A força máxima de flexão (FMF) e a força de ruptura (FR) foram determinadas. As informações coletadas foram analisadas com o teste one-way ANOVA, para p≤0,05. Análises por microscopia óptica foram realizadas para estudo dos componentes após os ensaios de resistência flexural. Os resultados sugeriram que houve diferença significante (p=0,000) na pré-carga residual antes e após carregamento mecânico entre os dois tipos de parafuso: os parafusos cone morse apresentaram torques de desaperto significativamente superiores aos apresentados pelos parafusos planos convencionais. Houve diferença significante nos resultados da FMF obtidos pelos parafusos planos convencionais e pelos parafusos cone morse (p=0,011), sendo que os conjuntos implante/abutment com parafusos cone morse apresentaram maior resistência à flexão. Para os resultados da FR houve influência significante do tipo de conexão (p=0,019), com melhores resultados para a conexão triângulo interno. Considerando as limitações deste estudo, concluiu-se que os parafusos cone morse apresentaram maiores torques de desaperto em comparação aos parafusos planos convencionais; que o design da conexão protética não teve influência significante sobre o torque de desaperto dos parafusos; que os parafusos cone morse obtiveram maiores valores de resistência à flexão, e que a conexão em triângulo interno obteve maiores valores para a força de ruptura. / The purpose of this study was to evaluate the mechanical behavior of two implant/abutment connection designs; external hex and internal tri-channel, using conventional screws and experimental conical screws. The study was divided in two parts; the first evaluated the effect of mechanical loading in the torque loss of the screws. 40 implants were used. The implants and abutments were divided in 4 groups: Group 1: external hex/conventional screw (HE); Group 2: tri-channel/conventional screw (TI); Group 3: external hex/conical screw (HECM); Group 4: tri-channel/conical screw (TICM). The abutments were installed in their respective implants with a tightening torque of 32Ncm, after a 10 minute interval, loosening torque were measured. The abutments were installed again with a 32Ncm torque, and after 10 minutes, they were mechanically loaded, simulating 1 year of normal oral function; after loading, loosening torques of the screws were measured again. Data were analyzed with one-way ANOVA test, with significance level of p≤0,05. Optical microscopy analysis were performed before and after the tests. The second part evaluated the flexural resistance of the implant/abutment assemblies. The same 40 assemblies were used. The tests were performed in an universal testing machine, with a 500kgf load cell, 1mm/min displacement, and 45° angulation. Maximum bending moment (FMF) and rupture force (FR) were determined. Collected information were analyzed with one-way ANOVA test, for p≤0,05. Optical microscopy analysis were performed for study of the components after the flexural resistance tests. The results suggested that there were significant differences (p=0,000) in the residual preload before and after mechanical loading between the two types of screws: conical screws showed significantly higher loosening torques than conventional flat screws. There were significant differences in the FMF obtained by the conventional flat screws and by the conical screws (p=0,000); the implant/abutment assemblies with conical screws presented higher flexural resistance. For the FR results, there was significant influence of the type of connection (p=0,019); the tri-channel connection presented better results. Considering the limitations of this study, it was concluded that the conical screws presented higher loosening torques compared to conventional flat screws; the design of the implant/abutment connection presented no significant influence on the loosening torques of the screws; conical screws showed higher bending moment values; and the tri-channel connection obtained higher rupture force values.
74

Eventos adversos das próteses metálicas autoexpansíveis esofágicas em pacientes com doença maligna avançada e sobrevida superior a 6 meses / Adverse events of self-expandable esophageal metallic stents in patients with long-term survial from advanced malignant disease

Medeiros, Vitor de Sousa 01 February 2019 (has links)
Introdução: as próteses metálicas autoexpansíveis (PMAE) são consideradas a melhor forma de tratamento paliativo da disfagia para pacientes com câncer avançado de esôfago. Os eventos adversos (EA) são uma grande preocupação, especialmente em pacientes com melhor prognóstico e maior sobrevida. O presente estudo teve como objetivo avaliar os EA de pacientes que sobreviveram por mais de 6 meses com a prótese esofágica no local. Métodos: análise retrospectiva de um banco de dados coletado prospectivamente incluindo todos os pacientes submetidos à colocação de prótese esofágica para o tratamento paliativo de doenças malignas e que permaneceram com a prótese por mais de 6 meses, durante o período de fevereiro de 2009 a fevereiro de 2014 em um centro acadêmico terciário. Resultados: sessenta e três pacientes foram incluídos. O seguimento médio foi de 10,7 meses. O sucesso clínico foi alcançado em todos os pacientes e a mediana da patência da prótese foi de 7,1 meses. Eventos adversos ocorreram em 40 pacientes (63,5%), totalizando 62 EA (média de 1,5 EA por paciente). O manejo endoscópico dos EA foi bemsucedido em 84,5% dos casos, com uma média de 1,6 reintervenções por paciente. A análise univariada revelou que a capacidade funcional, a idade e a radioterapia pós-prótese apresentaram tendência ao maior risco de EA. A análise multivariada revelou que apenas a capacidade funcional foi associada a EA (p = 0,025; HR = 4,1). Conclusão: eventos adversos são comuns em pacientes com prótese metálica de esôfago por período prolongado para paliação de doenças malignas. No entanto, o evento adverso não foi relacionado com maior taxa de mortalidade, e a maioria das complicações pôde ser manejada endoscopicamente com sucesso. Apenas a capacidade funcional foi um fator de risco para os EA. Os presentes dados sugerem que a prótese metálica é uma opção válida para a paliação de condições esofágicas malignas, mesmo quando se espera sobrevida maior que 6 meses / Background and Aims: self-expandable metallic stents (SEMS) are considered the best palliative treatment of dysphagia for patients with advanced esophageal cancer. Adverse events (AE) are a major concern, especially in patients with better prognosis and longer survival. The present study aimed to evaluate the AE of patients who survived longer than 6 months with esophageal stents in place. Methods: retrospective analysis of a prospectively collected database including all patients submitted to esophageal stent placement for the palliation of malignant diseases, during the period from February 2009 to February 2014 at a tertiary-care academic center, who remained with the stent longer than 6 months. Results: sixtythree patients were included. Mean follow-up was 10,7 months. Clinical success was achieved in all patients, and the median stent patency was 7,1 months. Adverse events occurred in 40 patients (63.5%), totaling 62 AE (mean 1.5 AE per patient). Endoscopic management of AE was successful in 84.5% of cases, with a mean of 1.6 re-interventions per patient. The univariate analysis revealed that performance status, age and post-stent radiotherapy presented a trend to higher risk of AE. The multivariate analysis revealed that only performance status was associated with AE (p = 0,025; HR = 4.1). Conclusions: AE are common in patients with long-term esophageal stenting for malignancy. However, AE was not related to higher mortality rate, and most complications could be successfully managed by endoscopy. Only performance status was a risk factor for AE. Our data suggest that metallic stenting is a valid option for the treatment of malignant esophageal conditions, even when survival longer than 6 months is expected
75

Estudo mecânico da conexão implante/abutment utilizando parafusos convencionais e parafusos experimentais cone morse / Mechanical study of the implant/abutment connection using conventional screws and experimental conical screws

Abílio Ricciardi Coppedê 15 July 2011 (has links)
A proposta deste estudo foi avaliar o comportamento mecânico de dois designs de conexão implante/abutment; hexágono externo e triângulo interno, utilizando parafusos convencionais e parafusos experimentais cone morse. O estudo foi dividido em duas fases: na primeira, foi avaliado o efeito do carregamento mecânico na perda de torque dos parafusos. 40 implantes foram utilizados. Os implantes e abutments foram divididos em 4 grupos: Grupo 1: hexágono externo/parafuso convencional (HE); Grupo 2: triângulo interno/parafuso convencional (TI); Grupo 3: hexágono externo/parafuso cone morse (HECM); Grupo 4: triângulo interno/parafuso cone morse (TICM). Os abutments foram instalados em seus respectivos implantes com torque de aperto de 32Ncm; após intervalo de 10 minutos, foram medidos os valores dos torques de desaperto. Os abutments foram instalados novamente com torque de 32Ncm, e após 10 minutos foram carregados mecanicamente, simulando 1 ano de função oral normal; após o carregamento, os torques de desaperto dos parafusos foram medidos novamente. Os dados foram analisados com o teste one-way ANOVA, com nível de significância de p≤0,05%. Análises por microscopia óptica foram realizadas antes e após os ensaios. Na segunda fase, foi avaliada a resistência à flexão dos conjuntos implante/abutment. Os mesmos 40 conjuntos foram utilizados. Os testes foram realizados em máquina universal de ensaios, com célula de carga de 500 kgf, deslocamento de 1mm/min, e inclinação de 45°. A força máxima de flexão (FMF) e a força de ruptura (FR) foram determinadas. As informações coletadas foram analisadas com o teste one-way ANOVA, para p≤0,05. Análises por microscopia óptica foram realizadas para estudo dos componentes após os ensaios de resistência flexural. Os resultados sugeriram que houve diferença significante (p=0,000) na pré-carga residual antes e após carregamento mecânico entre os dois tipos de parafuso: os parafusos cone morse apresentaram torques de desaperto significativamente superiores aos apresentados pelos parafusos planos convencionais. Houve diferença significante nos resultados da FMF obtidos pelos parafusos planos convencionais e pelos parafusos cone morse (p=0,011), sendo que os conjuntos implante/abutment com parafusos cone morse apresentaram maior resistência à flexão. Para os resultados da FR houve influência significante do tipo de conexão (p=0,019), com melhores resultados para a conexão triângulo interno. Considerando as limitações deste estudo, concluiu-se que os parafusos cone morse apresentaram maiores torques de desaperto em comparação aos parafusos planos convencionais; que o design da conexão protética não teve influência significante sobre o torque de desaperto dos parafusos; que os parafusos cone morse obtiveram maiores valores de resistência à flexão, e que a conexão em triângulo interno obteve maiores valores para a força de ruptura. / The purpose of this study was to evaluate the mechanical behavior of two implant/abutment connection designs; external hex and internal tri-channel, using conventional screws and experimental conical screws. The study was divided in two parts; the first evaluated the effect of mechanical loading in the torque loss of the screws. 40 implants were used. The implants and abutments were divided in 4 groups: Group 1: external hex/conventional screw (HE); Group 2: tri-channel/conventional screw (TI); Group 3: external hex/conical screw (HECM); Group 4: tri-channel/conical screw (TICM). The abutments were installed in their respective implants with a tightening torque of 32Ncm, after a 10 minute interval, loosening torque were measured. The abutments were installed again with a 32Ncm torque, and after 10 minutes, they were mechanically loaded, simulating 1 year of normal oral function; after loading, loosening torques of the screws were measured again. Data were analyzed with one-way ANOVA test, with significance level of p≤0,05. Optical microscopy analysis were performed before and after the tests. The second part evaluated the flexural resistance of the implant/abutment assemblies. The same 40 assemblies were used. The tests were performed in an universal testing machine, with a 500kgf load cell, 1mm/min displacement, and 45° angulation. Maximum bending moment (FMF) and rupture force (FR) were determined. Collected information were analyzed with one-way ANOVA test, for p≤0,05. Optical microscopy analysis were performed for study of the components after the flexural resistance tests. The results suggested that there were significant differences (p=0,000) in the residual preload before and after mechanical loading between the two types of screws: conical screws showed significantly higher loosening torques than conventional flat screws. There were significant differences in the FMF obtained by the conventional flat screws and by the conical screws (p=0,000); the implant/abutment assemblies with conical screws presented higher flexural resistance. For the FR results, there was significant influence of the type of connection (p=0,019); the tri-channel connection presented better results. Considering the limitations of this study, it was concluded that the conical screws presented higher loosening torques compared to conventional flat screws; the design of the implant/abutment connection presented no significant influence on the loosening torques of the screws; conical screws showed higher bending moment values; and the tri-channel connection obtained higher rupture force values.
76

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Murillo Sucena Pita 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
77

Avaliação de dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e barra articulada / Evaluation of two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar

Silva, Rafael Cândido Pedroso e 27 January 2016 (has links)
O objetivo deste estudo foi avaliar dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e Barra Articulada. Após ciclagem termomecânica, foram analisadas a perda de torque dos parafusos protéticos e adaptação marginal vertical e horizontal. Ao final, as próteses foram submetidas a ensaios de fadiga acelerada progressiva e resistência à fratura. Foram confeccionadas 48 próteses totais fixas implantossuportadas, as quais foram divididas inicialmente em dois grupos, G1 protocolo convencional; G2 - &ldquo;All-on-4&rdquo;. De acordo com a técnica de fabricação das infraestruturas, estes grupos foram divididos em três subgrupos, A - tecnologia CAD-CAM; B - fundição convencional; C - Barra Articulada, proporcionando seis amostragens diferentes: G1A, G1B, G1C, G2A, G2B e G2C (n=8). Todas as próteses foram avaliadas em relação à adaptação marginal vertical e horizontal, utilizando MicroCT, antes e após a ciclagem termomecânica (2.000.000 de ciclos). A perda de torque dos parafusos protéticos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). Após este ensaio, as próteses foram submetidas ao teste de fadiga acelerada progressiva (n=8) e em sequência, ensaio de resistência à fratura (n=6). A perda de torque teve diferença significante para todos os tempos comparados (p<0,01), exceto em G2B, onde a comparação entre T1 - T2 não mostrou diferença significante (p=0,72). A comparação entre G1 e G2 não foi significante. A comparação entre os subgrupos A, B e C teve diferenças significantes em G1T1, G1T2, G2T1 e G2T2 quando comparados os subgrupos A - B e B - C, todos com (p<0,01). Não houve diferenças significantes para a adaptação marginal vertical e horizontal antes e depois da ciclagem em todos os grupos. Na comparação de G1 e G2, houve diferença significante para a adaptação vertical e horizontal apenas no subgrupo B, nos dois tempos, ambos com (p <0,01). Na comparação dos subgrupos A, B e C, houve diferenças significantes em G1 antes e depois; e G2 antes e depois, quando comparados os subgrupos A - B e B - C, todos com (p<0,01) para a adaptação vertical e horizontal. Já para a adaptação horizontal, esta comparação foi significante apenas em G2 antes e depois, ambos com (p=0,02). Em relação à resistência à fratura, a comparação entre G1 e G2, foi significante em todos os subgrupos, A e C (p<0,01), B (p=0,02). A comparação dos subgrupos A, B e C, também foi significante em relação à resistência à fratura das próteses em todos os grupos (p<0,01). Pode-se concluir que a simulação de ciclos mastigatórios teve influência significante sobre a perda de torque dos parafusos protéticos, porém não influenciou significativamente a adaptação marginal vertical e horizontal das próteses; desadaptações marginais influenciaram significativamente no afrouxamento dos parafusos protéticos; as próteses dos subgrupos A e C obtiveram resultados significantemente melhores para a adaptação marginal vertical e horizontal quando comparadas às do subgrupo B, sendo que na adaptação horizontal, as do subgrupo A tiveram resultados melhores que as do C; a quantidade e distribuição dos implantes não influenciou na perda de torque dos parafusos protéticos em todas as situações, porém teve influência significativa na adaptação marginal vertical e horizontal das próteses do subgrupo B; todas as próteses sobreviveram ao ensaio de fadiga acelerada progressiva; em relação ao ensaio de resistência à fratura, as próteses do G2, tiveram resultados significantemente melhores que as do G1, o subgrupo B obteve valores significantemente maiores de resistência na região do cantilever, quando comparadas ao subgrupos A e C; o subgrupo A obteve os menores valores de resistência. / The objective of this study was evaluate two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar. After thermomechanical cycling, were analyzed prosthetic screws loosening and vertical and horizontal marginal adaptation. In the end, the prostheses were submitted to tests of progressive accelerated fatigue and fracture resistance. Were made 48 implant-supported fixed dentures, which initially were divided into two groups, G1 - conventional protocol; G2 - \"All-on-4\". According to the technique of manufacturing infrastructure, these groups were divided into three subgroups: A - CAD-CAM technology; B - conventional casting; C - Articulated bar, providing six different samples: G1A, G1B, G1C, G2A, G2B e G2C (n=8). All samples were evaluated in the vertical and horizontal marginal adaptation using MicroCT before and after the thermomechanical cycling (2,000,000 cycles). The loosening of the prosthetic screws was analyzed before (T0), 1,000,000 (T1) and 2,000,000 cycles (T2). After this test, the prostheses were submitted to progressive accelerated fatigue test (n = 8) and sequentially fracture resistance test (n = 6). The prosthetic screw loosening has significant difference for all time compared (p <0.01), except in G2B where the comparison between T1 - T2 showed no significant difference (p = 0.72). The comparison between G1 and G2 was not significant. The comparison between subgroups A, B and C had significant differences in G1T1, G1T2, G2T1 and G2T2 compared subgroups A - B, B - C, all of (p <0.01). There were no significant differences for vertical and horizontal marginal adaptation before and after cycling in all groups. Compared to G1 and G2, there was a significant difference for vertical and horizontal adjustment only in the subgroup B in two stages, both (p <0.01). In the comparison of subgroups A, B and C, there were significant differences G1 before and after; and G2 before and after, when compared subgroups A - B, B - C, all of (p <0.01) for vertical and horizontal adaptation. As for the horizontal adaptation, this comparison was significant only in G2 before and after, with both (p = 0.02). With regard to fracture resistance, the comparison between G1 and G2 was significant in all subgroups, A and C (p <0.01), B (p = 0.02). The comparison of subgroups A, B and C was also significant compared to the fracture resistance of the prosthesis in all groups (p <0.01). It can be concluded that the simulation of mechanical cycling had significant influence on the loosening of prosthetic screws, but did not significantly influence the vertical and horizontal marginal fit of the prosthesis; marginal adaptation significantly influenced the loosening of prosthetic screws; the prostheses of the subgroups A and C had significantly better results for the vertical and horizontal marginal adaptation when compared to the subgroup B, and in the horizontal adaptation, the sub-group A had better results than those of C; the amount and distribution of the implants did not affect the prosthetic screws loosening in all situations, but had significantly influence in vertical and horizontal marginal adaptation of subgroup B prostheses; all samples survived in progressive accelerated fatigue test; in relation to the fracture resistance test, the prosthesis G2, had significantly better results than the G1, the B subgroup achieved significantly higher values of resistance in the cantilever region, when compared to subgroups A and C; the subgroup C obtained the smallest resistance.
78

Avaliação da força de repulsão entre magnetos de neodímeo ferro boro usados em tratamentos intra e extra bucais / Evaluation of repulsion force between Neodymium Iron Boron magnets used for intra and extra oral treatments

Sanchez, Renato Sartori Lardin 15 February 2012 (has links)
Os magnetos de Neodímio Ferro Boro (Nd2Fe14B) apresentam excelentes propriedades magnéticas e compatibilidade biológica, embora sejam frágeis e possuam baixa resistência à corrosão. As forças de atração magnética de magnetos de terras raras têm sido empregadas em sistemas de retenção, principalmente associadas aos implantes osseointegráveis, em próteses bucais e próteses faciais, bem como em aparelhos ortodônticos. Este estudo avalia o comportamento das forças de repulsão magnética, em função do volume e comprimento do eixo magnético, quando submetidos a afastamentos, de modo que esta propriedade física seja empregada em odontologia. Vinte e quatro corpos de prova, com um ou dois pares de magnetos de Nd2Fe14B, com diferentes formas e volumes variados, foram submetidos a ensaio mecânico para mensuração das forças de repulsão magnética, em condições de afastamentos que variaram entre 0,0 e 20,0 mm. Os dados observados mostram que, considerando-se uma mesma área superficial de polo, a força de repulsão magnética varia em função do comprimento do eixo magnético. Os dados relativos ao afastamento foram submetidos a análise de variância (p0,05), tendo-se observado que o aumento da distância entre os magnetos diminui significantemente a força de repulsão magnética na maioria dos corpos de prova. No afastamento 0,0 mm as forças magnéticas de repulsão dos subgrupos mantêm uma sequência crescente a partir do subgrupo de menor volume de magnetos ao subgrupo de maior volume de magnetos, os quais permanecem nessa sequência nos afastamentos iniciais. A força de repulsão magnética gerada por magnetos pequenos varia menos em função do aumento do afastamento. Conclui-se que a variação da força de repulsão magnética, dada a mesma área superficial de polo, apresenta uma relação direta com o volume e com o eixo magnético onde, quanto maior o volume ou o comprimento do eixo magnético, maior a força de repulsão magnética. A relação direta entre volume e força de repulsão magnética não se altera frente aos afastamentos inicais, tendendo a se tornar imensurável com o aumento da distância. A força de repulsão magnética mantém uma relação inversa com a distância entre os pares de magnetos. Este ensaio mecânico indica que a força de repulsão magnética apresenta, assim como a força de atração magnética, uma curva hiperbólica de redução frente ao aumento do afastamento. / Neodymium Iron Boron (Nd2Fe14B) magnets exhibit excellent magnetic properties and demonstrate biological compatibility, despite of their fragility and low resistance to corrosion. The magnetic attraction forces of rare earth magnets have been used in retention systems mainly associated with osseointegrated implants, in oral and facial prostheses, as well as orthodontic appliances. This study evaluates the repulsion forces of magnets, varying volume and length of magnetic axis when subjected to vertical distance, in order to assess the usefulness of such physical property in clinical situations. Twenty-four specimens, with one or two pairs of Nd2Fe14B magnets, presenting different shapes and various volumes, were subjected to mechanical testing so as to measure magnetic repulsion forces, under conditions of vertical pole face separation ranging from 0.0 to 20.0 mm. Repulsive magnetic force varies depending on the length of the magnetic axis, when considering the same surface area of a pole. Analysis of Variance - (p0.05) indicated that by increasing the distance between the pairs of magnets, magnetic repulsion force significantly reduces in most of the specimens. Starting at a 0.0 mm distance, the magnetic repulsion forces keep an enhancing sequence from lower to higher magnetic volume, holding these characteristics during initials distances. Repulsion magnetic forces generated by small magnets varies less as the distance increases. The results indicate the repulsion magnetic force variation, fixing the same pole surface area, presenting a direct relationship between volume and magnetic axis, since the increase of the volume or of the magnetic axis length leads to a higher magnetic repulsive force. The relationship between volume and magnetic repulsion force does not vary at initial distance. Nevertheless, when such distance increases, the force between the magnets significantly decreases. The magnetic repulsion force holds an inverse relationship with respect to the distance between magnets pairs. This mechanical test indicates that the magnetic repulsion force, as well the magnetic attraction force, present a hyperbolic curve of force reduction due to the increasing vertical distance.
79

Segurança biológica de implantes mamários de silicone: interrelação entre processos esterilizantes e biocompatibilidade / Biological safety of silicone mammary implants: interrelationship between sterilization processes and biocompatibility

Janice Campos de Azevedo 25 March 2004 (has links)
Os implantes mamários de silicone têm sido empregados, tanto nas cirurgias de aumento das mamas, quanto na reconstrução do tecido mamário após mastectomia. A segurança biológica dos implantes de silicone merece estudo relacionado aos processos de esterilização empregados, pois podem constituir-se em fator de comprometimento da estrutura química do polímero e, conseqüentemente, da biocompatibilidade. Este estudo consistiu na avaliação da biocompatibilidade de implantes mamários de silicone após terem sido submetidos aos processos de esterilização por calor seco, radiação gama e óxido de etileno. O parâmetro avaliado foi a viabilidade celular, empregando o método de difusão em agar e de captura do vermelho neutro. As amostras compreenderam implantes de silicone gel lisos, texturizados e revestidos com poliuretano e implantes texturizados pré-cheios com solução salina. Também foi realizado o teste de endotoxinas bacterianas pelo método do LAL e determinação da taxa de migração do gel de silicone (teste de bleed). Os três métodos de esterilização mostraram-se igualmente eficientes pela comprovação da condição de esterilidade dos implantes através de metodologia descrita na Farmacopéia Americana 27 edição. Os níveis de endotoxinas bacterianas dos implantes, também atenderam aos requisitos dos compêndios oficiais. Na avaliação da biocompatibilidade todos os implantes, independente dos processos de esterilização utilizados, apresentaram ausência de citotoxicidade. Os resultados do teste de bleed mostraram uma maior taxa de migração de gel para os implantes de superfície lisa em comparação com os implantes de superfície texturizada e revestida com poliuretano, quando esterilizados por calor seco. Ao comparar a taxa de migração do gel para os implantes de superfície lisa esterilizados por calor seco e óxido de etileno, obteve-se uma maior taxa de migração para aqueles implantes esterilizados por óxido de etileno. As diferentes avaliações realizadas neste estudo abrangeram aspectos biológicos, químicos e físicos relevantes para garantir um produto de boa qualidade e que, por assegurar a manutenção da característica de biocompatibilidade, resulta na segurança biológica deste tipo de implante. / Silicone breast implants have been widely used for mammary augmentation and reconstruction surgery. Biological safety of these implants can be damaged by sterilization methods. This study consisted of the biocompatibility assessment of breast implants through cell viability, employing the agar diffusion test and neutral red uptake. Four silicone breast implants were tested: smooth, textured, polyurethane covered silicone gel breast implant and textured saline-filled breast implant. Sterilization methods comprised dry-heat, ethylene oxide and &#947;-radiation. Detection of bacterial endotoxins employing LAL test and gel bleed was also performed. The three methods of sterilization revealed equally efficacious, through the sterility confirmation of implants employing methodology described in 27th edition of United States Pharmacopeia. At the same way the leveis of bacterial endotoxins of implants accorded with the pharmacopeial requirements. In theevaluation of biocompatibility ali the implants, independently of the sterilization process used, showed no cytotoxicity signals. The results of gel bleed revealed a higher migration rate from the smooth implants in comparison with the textured and polyurethane-covered implants sterilized by dry-heat. When was compared the gel migration of smooth implants sterilized by dry-heat and ethylene oxide, was obtained a higher rate of gel bleed of those implants sterilized by ethylene oxide. The different evaluations performed in this study comprised biological, chemical and physical aspects, that are relevant to assure a good quality product and by having maintained the characteristics of biocompatibility, resulted in the biological safety on this kind of implant.
80

"Tratamento dos tumores avançados da junção esofagogástrica por prótese auto-expansível com válvula anti-refluxo" / Antireflux valve self-expanding stent in the treatment of advanced gastroesophageal junction tumors

Cheng, Spencer 14 December 2005 (has links)
Introdução: A colocação de próteses através da junção esofagogástrica propicia o refluxo gastroesofágico. Objetivos e métodos: Avaliação da paliação da disfagia, manifestações broncoaspirativas, parâmetros nutricionais e qualidade de vida de 30 pacientes com tumores avançados da junção esofagogástrica tratados por prótese metálica auto-expansível com válvula anti-refluxo de 2001 a 2004. Resultados: Melhora da disfagia e regurgitação. Sem alteração na tosse, eructação, pirose, parâmetros nutricionais e qualidade de vida. Conclusões: A prótese com válvula anti-refluxo foi eficaz na paliação da disfagia, impediu a ocorrência de manifestações broncoaspirativas, não interferiu nos parâmetros nutricionais e qualidade de vida / Background: Placement of stents through the gastroesophageal junction can cause reflux. Objective and methods: Evaluate dysphagia palliation, aspiration symptoms, nutritional parameters and quality of life in 30 patients treated for advanced gastroesophageal junction tumors with a self-expanding metal stent with anti-reflux valve from 2001 to 2004. Results: Dysphagia and regurgitation symptoms improved after placement. There was no changes in heartburn, cough, belching symptoms and also no improvement in nutritional parameters or quality of life. Conclusions: Antireflux valve self-expanding stents was effective in dysphagia palliation, avoided aspiration symptoms and did not affect nutritional parameters or quality of life

Page generated in 0.274 seconds